Vous êtes sur la page 1sur 2

Region Calor T1F T1C T2F T2C Delta 1

1 17.9 50 100 70 110 50


2 143.2 100 110 165.947 180 10
3 207.9 165.947 180 200 248.105 14.053
4 209.7 200 248.105 202 250 48.105
5 234.9 202 280 230 280 78

FCp (kW/ºC) 0.95 0.84 1

Region DTC DTF A (Caliente) B (Caliente) C (Fria) D (Fria)


1 10 20 1 1 0 0
2 70 65.947 1 1 1 1
3 68.105 34.053 0 1 1 1
4 1.895 2 1 0 0 1
5 0 28 0 0 0 1

Region DTC DTF A (Caliente) B (Caliente) C (Fria) D (Fria)


1 10 20 47.5 42 0 0
2 70 65.947 332.5 294 329.735 296.7615
3 68.105 34.053 0 286.041 170.265 153.2385
4 1.895 2 9.00125 0 0 9
5 0 28 0 0 0 126
Delta 2 Diferencia T LN ΔT
40 10 0.22314355 44.8142012
14.053 -4.053 -0.3402508 11.9118014
48.105 -34.052 -1.23055023 27.672174
48 0.105 0.00218511 48.0524809
50 28 0.44468582 62.9658034

Qmin Cal Qmin Enf.


0.9 25.2 17.9
Corriente Tin (ºC) Tout (ºC)
A 250 100
Vapor Agua de enf. B 180 100
0 1 C 100 200
0 0 D 100 230
0 0
0 0
1 0

Vapor Agua de enf. Suma (Q/h) Area Costo h (kW/m2 ºC)


0 89.5 179 3.99426957 2459.99538 0.2 A
0 0 1252.9965 105.189505 20619.687 0.2 B
0 0 609.5445 22.0273441 7463.20531 0.2 C
0 0 18.00125 0.37461645 528.240204 0.2 D
126 0 252 4.00217239 2463.15797 0.2 Agua y vapor
Total 135.587908 33534.2859