PSA NITROGEN GENERATOR DATA SHEET (Form QF200-2) 18167 Edison Ave.

, Unit I
Model: HNS- 1250 Chesterfield, MO 63005
Project No: J1415 Serial No: J1415-1812 Phn: (636) 532-6613
2 . . . . www.holtecllc.com Fax: (636) 536-7863
1 . . . . Holtec Client/Dist: Valley Compressed Air
0 For proposal . . . End User Schneider
Rev DESCRIPTION PREP CHK APP Location: 0
Service: Other
SITE CONDITIONS
1 Indoor / Outdoor: Indoor Wind rating (if req'd): Not specified
2 Ambient Temp (min / max): 40 / 95 °F Speed: Not specified mph
3 (SI units) (min / max): 4 / 35 °C Details: .
4 Relative Humidity (max): 95 % Seismic rating (if req'd): Not specified
5 Altitude (if supplying compressor): 0 ft above sea level Details: .
6 Ingress protection type (controls): Nema 1 (general purpose) Corrosive area?: Normal
7 Hazardous location: Non-hazardous Details: .
8 FACILITY AIR SUPPLY
9 Compressor supplied by: Customer Air pressure available at Air Receiver: 110 psig
10 compressor type, model: Lubricated . Air Supply Temp after Air Receiver (min/max): 60 / 95 °F
Dryer supplied by: Customer (SI units) (min / max): 16 / 35 °C
dryer type, model: Refrigerated . Notes: .
Filtration supplied by (see below): Customer
###
### APPLICATION REQUIREMENTS (From customer specifications) NITROGEN GENERATOR RATING (Holtec design performance ratings)
### Nitrogen purity required: 99.9900 % (N2+Ar) Nitrogen purity required: 99.9900 % (N2+Ar)
Allowable O2: 0.0100 % O2 100 ppm Allowable O2: 0.0100 % O2 100 ppm
### Nitrogen flow required: 128.4 scfm = 206.48 Nm3/h Nitrogen flow: 128 scfm
### Nitrogen pressure required: 85.34 psig = 5.88 barg Nitrogen pressure (min): 85.00 psig
### Dewpoint (max allowed): 32 °F = 0 °C N2 Dewpoint (max): 32 deg F
### Air consumed (max allowed): 495.2 scfm = 796.31 Nm3/h Air consumed (± 5%): 495 scfm
### Waste gas (approx): 367 scfm
### Waste gas % (approx): 27 %
### Sound: 0 dBa
### FACILITY ELECTRIC POWER AVAILABLE NITROGEN GENERATOR ELECTRICAL LOAD
### Facility power (compres): Compressor
V byCompressor
othersphaseby others 60 hz Facility power (compres): Compressor
Compby
by
Compressor
others
Other
Compby
byothers
Other 60 Hz
### Facility power (N2 Gen): 115 V 1 phase 60 hz Facility power (N2 Gen): 115 V 1 ph 1 A
###
###
### MECHANICAL DESIGN SPECIFIED BY CUSTOMER ACTUAL MECHANICAL DESIGN OF NITROGEN GENERATOR (VESSELS, PIPING)
### Design pressure required: 150 psig = 10.3 barg Design pressure rating: 150 psig = 10.3 barg
### Design temperature required: 200 deg F = 93 °C Design temperature rating: 200 °F = 93 °C
### Design code(s) Not specified Design code(s) ASME VIII Div.1
###
### PIPING MATERIALS AND CONNECTIONS SPECIFIED BY CUSTOMER PIPING DESIGN OF NITROGEN GENERATOR - ACTUAL
### MATERIAL SIZE & CONN TYPE MATERIAL SIZE & CONN TYPE
### Piping - feed air to adsorbers Mfr Std Mfr Std Mfr Std Piping - feed air to adsorbers Galvanized steel 3" 150#
### Valves - feed air to adsorbers Mfr Std Valves - feed air to adsorbers Bronze/brass
### Piping - N2 after adsorbers Mfr Std Mfr Std Mfr Std Piping - N2 after adsorbers Galvanized steel 1.5" FNPT
### Valves - N2 after adsorbers Mfr Std Valves - N2 after adsorbers Bronze/brass
### Waste gas piping Mfr Std Waste gas piping Carbon steel 8" 150#
Pipe waste gas out of building? TBD Pipe waste gas out of building? TBD
Notes: . Notes: .

###
### PAINT SPECIFIED BY CUSTOMER PAINT TO BE SUPPLIED
Type: Mfr Std Color: . Type: Powder-coat &/or Acrylic polysiloxane Color: RAL-7035 (Light gray)
Notes: . Notes: .
### FILTERS REQUIRED FOR N2 GENERATOR
### Grade/Type Minimum rated capacity Supplied by
### F-000 Water separator (Standard) 792.32 scfm @ 10psig under nominal air receiver pressure Customer
### F-001 Pre-filter 1µ coalescing 792.32 scfm @ 10psig under nominal air receiver pressure Customer
### F-002 2nd filter: .01µ coalescing 792.32 scfm @ 10psig under nominal air receiver pressure Customer
### F-003 Carbon filter: Activated carbon 792.32 scfm @ 10psig under nominal air receiver pressure Customer
### F-004 Particulate filter: (not speced) 792.32 scfm @ 10psig under nominal air receiver pressure Customer
###
### INSTRUMENTATION SPECIFIED BY CUSTOMER INSTRUMENTATION INCLUDED WITH NITROGEN GENERATOR
### O2 analyzer type, range: Not specified O2 analyzer type, range: Zirconia, ppm
### Analog signals Mfr Std Analog signals avail to user: 4-20mA O2
### Discrete interlocks: Mfr Std Discrete interlocks: Not included
### Temperature sensors: Mfr Std Temperature sensors: Not included
### Pressure transmitters: Mfr Std Pressure transmitters: Internal use
### Pressure gauges: Mfr Std Pressure gauges: 4 (Adsorbers, feed air, instrument air)
### Indicators: Mfr Std Indicators: Running, Standby, High O2
### PLC/HMI: Mfr Std PLC/HMI: AB PLC, 4" Monochrome
### Calibration gas to use: Inlet Air
### Notes: . Notes: .
### . .
###
### MAX SIZE/WEIGHT ALLOWED BY CUSTOMER ("0" IF MAXIMUMS UNSPECIFIED) NITROGEN GENERATOR ESTIMATED SIZE WEIGHT
### L x W x H: Mfr Std in L x Mfr Std in W x Mfr Std in H L x W x H: 95 in L x 53 in W x 173 in H
### Weight: Mfr Std lb Weight: ##### lb
### ADDITIONAL NOTES:
### [1] .
### [2] .
### [3] .
### [4] .

J1415 QF200-2 PSA Datasheet.xlsx


###