Preamble to SBOQ for Railway Electrification and
General Electrical Works
A. General Instructions

1. The bill of quantities (BOQ) shall be read in conjunction with the Instruction to bidders,
General Conditions of Contract, Particular Conditions of Contract, Works requirements,
Technical specifications & Drawings, Explanatory notes detailed after BOQs of RE &
General Electrical works seperately, Payment conditions, pre-bid clarifications and
Addenda and Corrigenda if any.

2. The summary of schedules is as under:

SN Bill/Schedule No. Description/Heading of Bill


1 16000 RE-General
2 17000 Switching Post Building
3 19000 OHE-Ferrous other than steel structures and
SPS
4 20000 OHE - Non Ferrous ’A’
5 21000 OHE - Non Ferrous ’B’
6 24000 TSS
7 27000 TSS-Spares
8 28000 Tools & Plants
9 29000 SCADA
10 30000A Galvanized Steel Structures
11 30000B Concrete for Foundation
12 30000C Miscellaneous Common Items of OHE/TSS
13 33000 General Electrical Works

3. The quantities given in the Bill of Quantities are estimated and provisional and are given to
provide a common basis for bidding. The basis of payment will be the actual quantities of
work ordered and carried out including spares to be handed over to Railway, as measured
by the Contractor and verified by the Engineer/Employer and valued at the rates and prices
tendered in the priced Bill of Quantities, where applicable, and otherwise at such rates and
prices as the Engineer may fix within the terms of the Contract. If any quantities which have
been supplied by the contractor and paid by RVNL are determined to be surplus by the
Engineer (except those quantities which become surplus due to change in
planning/scheme by Railway/RVNL) during the progress of the work or at the completion of
the work, shall be taken back by the contractor, and the payment made for such materials
shall be recovered from the pending claims. The materials which have become surplus due
to change in planning/scheme by Railways/ RVNL and are still in usable condition shall be
taken over by RVNL and any part payment still to be made shall be released to the
contractor.
Cables/Catenary/Contact wire shall be measured in length for the types used in the works
and the 2nd stage payment for these Cables/Catenary/Contact wire shall be as per actual
length measured after laying/erection. The unused cut pieces generated during
laying/erection shall not be measured and cost of such cut pieces shall be deemed to be
included in the rates.

Page 1 of 10
4. In the Bill of Quantities, quantity and unit rates and thereby the amount against each
item have been indicated. From this, the estimated price of each bill has been worked
out and indicated in the summary sheet in BOQ. The Bidder shall quote rates as
percentage above/below/at par for each schedule in the summary sheet. If no
percentage as above, below or at par is indicated for any particular bill, the same will be
considered as percentage at par.

5. The rates for each bill shall be written in indelible ink or type written in the summary
sheet against each bill, in both words and figures, while clearly indicating whether the
percentage quoted is above/below/at par over the estimated rate in the respective
columns. The price for each bill shall accordingly be calculated and written against each
bill in both words and figures. The total price, as the sum of prices of all bills shall be
shown at the bottom of the summary sheet. The total price shall also be written in both
words and figures.

6. General directions and descriptions of work and materials are not necessarily repeated
or detailed in the Bill of Quantities. References to the relevant specifications and
sections of the contract documentation should be referred to before quoting rates in the
Bill of Quantities.

7. The rates and prices Bid in the priced Bill of Quantities shall, except as otherwise
provided under the Contract, include all construction equipment, plant, labour,
supervision, materials, transport, erection, maintenance, insurance, profit, royalty, octroi,
taxes and duties, together with all general risks, liabilities and obligations set out or
implied in the Contract.

8. The rates are deemed to be inclusive of all lead (except as otherwise specifically
provided in the description of the particular item), lifts, ascend, descend, handling,
rehandling crossing of nallah/streams/tracks and any other obstructions.

9. All enabling works for executing the work e.g. approach road to site, launching
arrangements, procuring right of way, removal of debris/bushes/trees, arrangement of
water and electricity etc is to be arranged by the contractor at his own cost and deemed
to be included in the quoted rates. Where a temporary tube well or any other water
source are constructed by the contractor in the railway land for the purpose of taking
power /water for construction purposes, no charge would be recovered from the
contractor but written permission will however, be obtained by the contractor from the
Engineer who may, at his discretion, refuse such permission for such construction of
temporary arrangement. The contractor shall also be required to restore the site to its
proper condition as directed by the Engineer.

10. Storage of Material: All the material at site will have to be properly stacked & stored so
as to facilitate inspection. The material should be properly protected from the detrimental
effects of nature and fire, theft etc. The contractor shall be responsible for watch & ward
and any loss or deterioration on account of above shall lead to rejection of material and
contractor has to replace the same at his own cost. All the disposable material should be
disposed off outside the railway boundary at a designated place as directed by the
Engineer. The area for storage of materials in open area shall be levelled and concreted
wherever necessary at the cost of contractor as per direction of Engineer. To avoid

Page 2 of 10
rusting of steel structures/tube such items should not be placed directly on ground. For
storing small OHE equipments, suitable bins shall be provided in contractor store depot.

11. The method of measurement of completed work for payment shall be in accordance with
provisions in Works Requirements (Specifications) except as otherwise specifically
provided in the description of item or particular bill of quantities or explanatory notes to
the particular bill of quantities.

12. Trees falling in the alignment or any other site of the works which belongs to the railways
will be trimmed and stacked at a nominated place at his /their own cost as directed by
Engineer and the same will be Railway/Employer’s property. Trees of the forest
department will be trimmed and deposited in the nearest forest depot. No separate
payment on this account shall be made to the contractor.

B. Instructions for quoting by the bidders

1. The prices for supply of materials and erection are in accordance with the technical
specifications, approved drawings and designs. The contractor should note that no item
of materials, equipment, fittings and components shall be supplied by the Employer.
2. UNIT PRICE:

i) The unit price indicated under “Supply” in the bills is the all inclusive price of
materials and all incidental charges for transport, loading/unloading and handling
etc.

ii) The price also include taxes, duties, levies (including octroi) applicable on Works
contracts, insurance/bank guarantee/indemnity bond charges etc.

iii) The prices also include provision for losses and wastages in transit and erection.

iv) The price quoted also include RITES/RDSO representative inspection and testing
charges unless otherwise specified in the bill of quantities or Technical
Specification. In case of change of inspection from RDSO/RITES to
RVNL/CONSIGNEE, 1% of the cost of material will be deducted by RVNL as
inspection charges.

(v) The unit price indicated under “Erection” in the bills should be inclusive of the cost
of erection and testing and also include all cost of administration of the contract,
insurance premia, banker’s charges, cost of stamps/storage/loading/unloading and
handling of materials and also include the cost of transportation which the
contractor may incur for carriage of material to the site of works. The unit prices
should also include cost of works and adjustment that may become necessary
during or after the tests for commissioning.
(vi) If for any item of work, rates for supply and erection are not separately mentioned,
80% of the item price shall be considered as supply rate and balance 20% shall be
taken as erection rates.
Page 3 of 10
3. The whole cost of complying with the provisions of the contract shall be included in the
items/bills provided in the BOQ and, where no items/bills are provided for any small
accessories/sub-items, the cost shall be deemed to be distributed among the rates and
amount entered for related Items of Works.

C. NOTES SPECIFIC TO PAYMENT: INVOICING PROCEDURE

1. All invoices shall be submitted with original supporting documents or certified


true copies of supporting documents wherever these are acceptable to the
Engineer as per contract. Where copies of original documents are required in
support of several invoices, true certified copies of the original documents may
be forwarded to the Engineer, with his consent.

2. Invoices shall be submitted only on the basis of provisions in Contract


Agreement and prices. The quantities and measurement of works completed
should be approved by the Engineer prior to the submission of invoices. For this
purpose, the schedule of quantities and measurement submitted by the
contractor for approval of the Engineer may be only up to the extent of work
completed except in the case of payments on Provisional Acceptance.

D. PAYMENT PROCEDURE

1. ON ACCOUNT PAYMENT AGAINST SUPPLY OF MATERIAL

On Account Payment will be made as described below:

(i) “On Account Payment” shall be made for the items specified in detailed
terms of payment of each schedule under clause No. 4.0 of this
preamble.
(ii) ‘On Account Payment’ shall be made to the extent of 85% of the
accepted supply rate, after receipt, acceptance, accountal, proper storage
and protection against loss, damage or deterioration on the items
mentioned in each schedule.
(iii) ‘On Account Payment’ made to the contractor will subsequently be
adjusted against progress payments and against payment due on
provisional acceptance.
(iv) All invoices shall be accompanied with the following, for the purpose of
arranging ‘On Account Payment’ against the contract:

a. Supplier’s Delivery Challans.


b. Inspection certificate granted by the authorized approved
agency/Purchaser’s representative as per contract agreement.
c. Certificate of receipt of material at Contractor’s depot/work sites duly
accepted by the Engineer.
d. Comprehensive Insurance Policy for supply and safe custody of
material.

Page 4 of 10
e. Indemnity Bond for any loss, theft, damage, or deterioration of
material for equivalent amount for which On Account Payment is
claimed.
f. Quality assurance documents like manufacturer test report,
Guarantee Certificate etc.

2. PROGRESS PAYMENT AGAINST SUPPLY AND ERECTION OF MATERIAL:


On completion of each item of BOQ, the contractor shall receive payment to the
extent of 95% of the supply and erection costs after making any recoveries and
adjusting of On Account Payment, which may be due.

3. REMAINING 5% PAYMENT: The balance 5% of each item of the BOQ shall be


paid to the contractor after commissioning of the portion of the work or handing
over of the installation/material to the employers/Railways representative. This is
applicable for all schedules.

4.0 PROCEDURE OF SCHEDULE WISE PAYMENTS

4.1 Schedule 16000:

(i) Schedule No. 16001 (Design & Drawing)

The payment shall be made as under:

(a) 50% of Scheduled rates shall be paid after “in principle approval
of design/drawings by RVNL”.
(b) 45% of Scheduled rates shall be paid after the submission &
acceptance of as erected/ completion drawings by RVNL.

(ii) All other items except item No. 16001:

(a) On Account Payment shall be made only for item Nos. 16009
and as per terms and conditions given in clause No. D(1) under
“Payment Procedure”.

(b) The Progress Payment to the extent of 95% of all the items in the
schedule shall be paid for the supply and erection prices after
adjustment of “On Account payment” & other recoveries, if any,
wherever applicable.

4.2 Schedule 17000:

i) 50% of the Schedule rate shall be paid on Casting of the Roof of the
Switching Station Building.
ii) 45% of the Schedule rate shall be paid on completion of the building in all
respects and certification by the Engineer.

Page 5 of 10
4.3 Schedule 19000:

(i) On Account Payment will be made only for item No. 19001, 19003 and
19004 and as per terms and conditions given in clause No. D(1) under
“Payment Procedure”.

(ii) Schedule No. 19003: On completion of erection of bracket assemblies,


the contractor shall receive payment to the extent of 85% of prices for
supply and erection of bracket assemblies. After final adjustment of OHE
and SED checking, contractor shall receive another 10% payment”.

(iii) The Progress Payment to the extent of 95% of all the items in the
schedule shall be paid for the supply and erection prices after adjustment
of “On Account payment” & other recoveries, if any, wherever
applicable.

4.4 Schedule 20000:

(i) On Account Payment will be made only for item Nos. 20002 & 20003
and as per terms and conditions given in clause No. D (1) under
“Payment Procedure”.

(ii) Item No. 20001: On completion of erection of the items the contractor
shall receive payment to the extent of 85% of the prices for supply and
erection.

(iii) The Progress Payment to the extent of 95% of all the items in the
schedule shall be paid for the supply and erection prices after final
adjustment of OHE and SED checking and after adjustment of “On
Account payment” & other recoveries, if any, wherever applicable.

4.5 Schedule 21000:

(i) On Account Payment will be made only for item Nos. 21002, 21003,
21004 & 21005 and as per terms and conditions given in clause No. D
(1) under “Payment Procedure”.

(ii) The Progress Payment to the extent of 95% of all the items in the
schedule shall be paid for the supply and erection prices after adjustment
of “On Account payment” & other recoveries, if any, wherever
applicable.

Page 6 of 10
4.6 Schedule 24000:

(i) Item No. 24001 (Design & Drawing of TSS)

(a) 50% of Scheduled rates shall be paid after the “in principle
approval of design/drawings by RVNL”.
(b) 45% of Scheduled rates shall be paid after the submission &
acceptance of as erected/ completion drawings by RVNL.

(ii) On Account Payment will be made only for item Nos. 24004 to 24014,
24032 to 24036, 24038 and as per terms and conditions given in clause
No. D(1) under “Payment Procedure”.

(iii) The Progress Payment to the extent of 95% of all the items in the
schedule shall be paid for the supply and erection prices after
adjustment of “On Account payment” & other recoveries if any
wherever applicable except item No. 24001 which will be paid as per (i)
above.
4.7 Schedule 27000 & 28000:

95% of the accepted price shall be paid on receipt & accountal of material at site or
required destination after inspection and production of documents as listed below:

(i) Supplier’s Delivery Challans.


(ii) Inspection certificate granted by the authorized approved
agency/Purchaser’s representative as per contract.
(iii) Certificate of receipt of material at Contractor’s depot/work sites duly
accepted by the Engineer.
(iv) Quality Assurance Documents including Guarantee/Warrantee, if any.

4.8 Schedule 29000:

(i) Item No. 29001 (Design & Drawing of SCADA)

(a) 50% of Scheduled rates shall be paid after the “in principle
approval of design/drawings by RVNL”.
(b) 45% of Scheduled rates shall be paid after successful completion
of the work and handing over of the soft & hard copies of as
erected/completion drawings & software to RVNL.
(ii) On Account Payment shall be made only for item Nos. 29002 to 29005
& 29007 to 29010 and as per terms and conditions given in clause No.
D(1) under “Payment Procedure”.

(iii) The Progress Payment to the extent of 95% of all the items in the
schedule shall be paid for the supply and erection prices after adjustment
of “On Account payment” & other recoveries if any wherever applicable
except item No. 29001 which will be paid as per clause (i) above.
Page 7 of 10
4.9 Schedule 30000:

(i) (a) On Account Payment shall be made only for item Nos. 30001 to
30003 and 30005, 30009 and as per terms and conditions given in
clause No. D(1) under “Payment Procedure”.
(b) The progress payment of the above items to the extent of 95% of
the supply and erection prices shall be paid after adjusting of “On
Account payment” & other recoveries.

(ii) Item Nos. 30006, 30007: On completion of foundation work, the


Contractor shall receive payment to the extent of 75% of the prices (for
supply and erection taken together calculated at gross volume of
concrete) of foundation and another 20% after mast erection, muffing,
backfilling etc.

(iii) Item No. 30008: On completion of work, Contractor shall receive


progress payment to the extent of 95% of the prices.

(iv) Item No. 30009: On completion of erection of structures, the


Contractor shall receive payment to the extent of 85% of the prices for
supply and erection of structures and another 10% after erection of
respective bracket assemblies/equipment.

4.10 SCHEDULE No. 33000 (General Electrical Works):

(i) 85% of the accepted supply rate shall be paid on receipt of


material at site, after inspection & against submission of an indemnity
bond.

(ii) Further payment of supply & erection cost to cover 95% of the total item
cost shall be paid on completion of the work and on certification by the
Engineer after adjusting already paid amount & other recoveries if any.

5. FINAL SETTLEMENT

On expiry of the defect liability period and issue of the taking over certificate of the
entire installation, the Bank Guarantee for Performance security shall be released to
the contractor after adjustment of any dues payable by the contractor.

6. RECOVERIES FROM THE CONTRACTOR

All the recoveries for materials supplied and services rendered by the Purchaser to
the Contractor and other refunds/recoveries due from the Contractor shall be made
by deductions from payments due to the Contractor covering the value of supply
and erection in the progress payment and from payments due on provisional
Acceptance.

Page 8 of 10
7. TAXES AND DUTIES

(i) All taxes, duties and levies (including octroi, works contract tax, service tax) arising
out of the transactions between the contractor and his sub-contractor/Suppliers for
this work will be deemed to be included in the accepted rates, unless otherwise
specified in the BOQ or technical specification.

(ii) Where the law makes it statutory for the Purchaser


to deduct any amount towards sales tax or any other taxes on works contract, the
same shall be deducted and remitted to the concerned authority.

8. PRICE VARIATION

Coefficients governing the adjustment of changes in cost to be read with clause


13.8 of GCC applicable to various schedules as included in the GCC.

******

Page 9 of 10
[Blank Page]

Page 10 of 10
Bill of Quantities
Package 1: General Electrical Works between PHEPHNA(PEP) - INDARA(IAA)(EXCLUDING INDARA)
Summary Sheet of Bill of qunatities
Bidder's % age above/at par/ below Total cost (INR)

In figures(% Write whether


Bill In words (%
Description of item Amount (Rs) above /below /at percentage
No. par on estimated
above /below /at par on
quoted is above /
In figures In words
estimated rates)
rates) below / at par

1 2 3 4 5 6 7 8

General Electrical
33 94,781,972
Works(Schedule Items)

4,109,970.00

General Electrical Works


33
(Non Schedule Items)

Total General Electrical


98,891,942
Works

(a)Please refer to ITB 14 and 32 while filling the rates in the summary sheet.
(b)Please mention the percentage rate, in both figures and words, for each schedule in columns 4 & 5 respectively. Please also mention in column 6 whether the percentage rate mentioned in columns 4 & 5 are above or below or at par over
the estimated rates.
(c)The price for each bill shall be calculated and written against each bill, in both figures and words, in columns 7 & 8 respectively.
(d)The total price, as sum of the price of all the bills/ schedules shall be shown, in both figures and words under columns 7 & 8 respectively in the last row of the summary sheet.
(e) Bidder should ensure that the rates are filled with due care and caution so as not to lead to any omission or discrepancy or ambiguity
Bill of Quantities
Package 2: General Electrical Works between MAU(MAU) - SHAHGANJ(SGH)(EXCLUDING MAU)
Summary Sheet of Bill of qunatities
Bidder's % age above/at par/ below Total cost (INR)
In words
In figures(% Write whether
(% above
above /below percentage
Bill No. Description of item Amount (Rs)
/at par on
/below /at
quoted is In figures In words
par on
estimated above / below /
estimated
rates) at par
rates)

1 2 3 4 5 6 7 8

General Electrical
33 144,697,290
Works(Schedule Items)

General Electrical
33 Works (Non Schedule 6,767,466
Items)

Total General
151,464,756
Electrical Works

(a)Please refer to ITB 14 and 32 while filling the rates in the summary sheet.
(b)Please mention the percentage rate, in both figures and words, for each schedule in columns 4 & 5 respectively. Please also mention in column 6 whether the
(c)The price for each bill shall be calculated and written against each bill, in both figures and words, in columns 7 & 8 respectively.
(d)The total price, as sum of the price of all the bills/ schedules shall be shown, in both figures and words under columns 7 & 8 respectively in the last row of the
(e) Bidder should ensure that the rates are filled with due care and caution so as not to lead to any omission or discrepancy or ambiguity
Bill of Quantities General Electrical Works in connection Phephna-Indara, Mau-
Shahganj (Excluding Indara-Mau) (150.28KM) Section of Varanasi Division of N E
Railway. Package-1 for Phephna -Indara (Excl. Indara)
SUMMARY SHEET (ELECTRICAL)
Revised Amount
SN SCHEDULE Desription
(In Rs.)
1 33 General Eelctrical Works (Schedule Items) 94,781,972.00
2 33 General Eelctrical Works (Non Schedule Items) 4,109,970.00
Total 98,891,942.00
Bill of Quantities General Electrical Works in connection Phephna-Indara, Mau-
Shahganj (Excluding Indara-Mau) (150.28KM) Section of Varanasi Division of N E
Railway. Package-2 for Mau - Shahganj (Excl Mau)

SUMMARY SHEET (ELECTRICAL)

SN
SCHED
Desription
Revised Amount
ULE (In Rs.)
1 33
General Eelctrical Works (Schedule Items) 144,697,290.00
2 33
General Eelctrical Works (Non Schedule Items) 6,767,466.00

Total 151,464,756.00
ELECTRICAL GENERAL SERVICES WORKS
SCHEDULE - 33000 ELECTRICAL GENERAL SERVICES WORKS
Bill of Quantities General Electrical Works in connection Phephna-Indara, Mau-Shahganj (Excluding Indara-Mau) (150.28KM) Package-1 for Phephna -Indara (Excl.
Indara) Section of Varanasi Division of N E Railway.
This schedule shall be read in conjunction with its Explanatory Notes and Technical Specifications for detailed description for various items included therein
Rates Amount Total
Item No. Description of items Unit Quantity
Supply Erection Supply Erection Amount
Electrification of staff quarter complete with point wirings, circuit
wirings, sub main wirings etc. with Fire Retardant (FR) PVC
insulated, multistranded, copper conductor, single core cable on
surface/ in recessed PVC conduits, along with provision of
luminaries with lamps, call bells, ceiling & exhaust fans,
33001
distribution boards, loose wire box, geyser, energy meters in M.S.
box including earthing with G.I. pipe electrode etc. as per scale of
fittings, and cable sizes, nos. of points permissible in each circuit
and sub main/s etc. for each type of quarter as indicated in
Explanatory Notes.
i) Type - I quarter Each 0 40,093 2 0 80186 80186
ii) Type - II quarter Each 0 42,172 8 0 337376 337376
iii) Type - III quarter Each 0 52,936 4 0 211744 211744
iv) Type - IV quarter Each 0 97,935 2 0 195870 195870
v) Type - V quarter Each 0 134,403 0 0 0 0
Extra for stair case light point controlled with two nos. two way
vi) Each 0 862 20 0 17240 17240
switches
ELECTRIFICATION OF GATE MAN LODGES AT LEVEL CROSSINGS
Electrification of gate man lodge complete with point wirings,
circuit wirings etc. with Fire Retardant (FR) PVC insulated,
multistranded, copper conductor, single core cable on surface/in
recessed PVC conduits, including provision of luminaries with
33002 Each 0 24,946 22 0 548812 548812
lamps, ceiling fan, distribution board, earthing with G.I. pipe
electrode etc. as per scale of fittings, cable sizes, nos. of points
permissible in each circuit and sub mains as indicated in
Explanatory Notes.
ELECTRIFICATION OF SERVICE BUILDINGS, PASSENGER SHELTER, SHEDS, PUMP HOUSE, SUB STATION BUILDINGS, OFFICES ETC AND ADDITIONAL
REQUIREMENT OF POINTS IN QUARTERS, LC GATES ETC.
Wiring for light/ ceiling fan/exhaust fan/call bell/light plug/ group
etc. points including circuit wiring, sub main wiring with Fire
Retardant (FR), PVC insulated, multistranded, copper conductor,
single core cable on surface/in recessed PVC conduits,
33003 (i) Point 0 1,556 1000 0 1556000 1556000
distribution boards, sub distribution boards, earthing etc. as
required. Wiring shall be done as per sizes of cables, no. of
points permissible in each circuit and sub mains as indicated in
Explanatory Notes.

Page 3 of 37
Rates Amount Total
Item No. Description of items Unit Quantity
Supply Erection Supply Erection Amount
Wiring for power plug point including circuit wiring, sub main
wiring with Fire Retardant (FR), PVC insulated, multistranded,
copper conductor, single core cable on surface/in recessed PVC
33003 (ii) conduits, distribution boards, sub distribution boards, earthing Point 0 2,857 200 0 571400 571400
with G.I. pipe electrode etc. as required. Wiring shall be done as
per sizes of cables, no. of points permissible in each circuit and
sub mains as indicated in Explanatory Notes.
Extra for provision of industrial type iron clad plug socket with
33003 (iii) Point 0 780 26 0 20280 20280
32A DP MCB in M.S. Box.
Multiplug points (power strip 3 no. 6A socket controlled by 16 A
33003 (iv) switch) similar to Legrand cat no. 6745.48 OR as approved by No. 1,857 92 8 14856 736 15592
engineer.
Supply of Light meter measuring up to 200000 lux with battery
33004 and carry case (HTC instruments make ref LX-103 or equivalent Nos 1,766 4 7064 0 7064
as approved by engineer)
SECTION - B : PROVISION OF LUMINARIES, FANS, WATER COOLERS ETC
Supply, installation, testing and commissioning of light sensitive
street light controller, 25 kW for street light/ High mast complete
with infrared sensors, contactors and MCB, terminal board etc.
33006 No. 46,180 2,008 6 277080 12048 289128
for 25 KW load, Operative Voltage 185-275 V AC. Make: Bajaj
Energy pack or equivalent as approved by Engineer.

Supply, installation, testing and commissioning of 230V A. C


ceiling fan 1400mm with double ball bearing and suitable
33008 capacitor complete with wiring with 1.5 sq.mm FR PVC insulated No. 2,339 367 240 561360 88080 649440
copper conductor, single/ three core cable as instructed etc. as
required.
33008A Supply and erection of 1200mm BLDC fan with remote 2,478 157 120 297360 18840 316200

Supply and fixing of stepped type, electronic fan regulator with


33009 suitable rating for the C/ Fan on the existing phenolic laminated No. 439 98 120 52680 11760 64440
sheet cover plate/ modular plate of switch box, including
connections, testing and commissioning as required.
Supplying, installation, testing and commissioning of 11-15 W
33010 A No. 230 36 40 9200 1440 10640
LED lamp as approved by Engineer.
Supply, erection, testing and commissioning of Recessed type
LED luminaries for 2x2 Grid ceiling, powder coated, CRCA
33010B housing, high efficiency reflector & diffuser cover, system No. 4,466 819 12 53592 9828 63420
wattage 35-45W suitable to work on 220-240V AC supply.

Page 4 of 37
Rates Amount Total
Item No. Description of items Unit Quantity
Supply Erection Supply Erection Amount
Supply, erection, testing and commissioning of LED down lighter
having pressure die cast aluminium housing white powder
33010C No. 1,683 608 8 13464 4864 18328
coated and acrylic cover, system wattage 14-16w suitable to
work on 220-240V AC supply.
Supply, erection, testing and commissioning of LED Street light
fitting ,pressure di-cast aluminium housing with suitable cover,
33010D
suitable to work on 220-240V AC supply with system wattage as
under :
(i) Fitting 43-48 W No. 6,503 547 30 195090 16410 211500
(ii) Fitting 35-40 W No. 5,550 547 200 1110000 109400 1219400
(iii) Fitting 70-74 W No. 10,067 547 40 402680 21880 424560
(iv)Fitting 23-27 W No. 2,458 548 40 98320 21920 120240
Supply and installation of surface /wall mounted, LED batten type
light fitting complete with LED Lamp with system wattage 18-22w
33010E No. 1,422 132 400 568800 52800 621600
suitable to work on 220-240V AC supply as approved by
engineer.
Supply and Installation of 7 watts sleek LED mirror light with
diffuser and Led lamp similar to Crompton Greaves Ltd Model
33010 F No. 1,964 35 20 39280 700 39980
LINNET LCL-07-CDL complete or superior as approved by
Engineer.
Supply, erection, testing and commissioning of LED flood light
fitting, pre die cast aluminium, IP-65 with high power LED as light
33010G No. 23,022 655 8 184176 5240 189416
source with system wattage 140-150 w suitable to work on 220-
240V AC supply as approved by Engineer.
Supply, erection, testing and commissioning of LED flood light
fittings pre die cast aluminium IP-65 with high power LED as light
33010H No. 32,463 655 8 259704 5240 264944
source with system wattage 200-210 w suitable to work on 220-
240V AC supply as approved by Engineer.
Supply, erection, testing and commissioning of LED flood light
fittings pre die cast aluminium IP-65 with high power LED as light
3301 I No. 15,792 655 8 126336 5240 131576
source with system wattage 90-110 w suitable to work on 220-
240V AC supply as approved by Engineer.
Supply, erection, testing, commissioning of exhaust fan suitable
for 1- phase, 230 Volts, AC supply system complete with
capacitor, louver shutters, grouting bolts with nuts, making
33011A opening/ modification in the wall to suit the size of the fan,
making good the damages, connections with 1.5sq. mm FR, PVC
insulated, multi stranded copper conductor, single core/ three
cable as instructed, earthing etc. as required.
(i) AC exhaust fan 300 mm 900 rpm with/ without louver shutters. No. 3,470 543 10 34700 5430 40130
(ii) AC exhaust fan 150 mm with louver shutters. No. 1,930 415 10 19300 4150 23450
(iii) AC exhaust fan 450 mm with/ without louver shutters. No. 8,326 415 10 83260 4150 87410

Page 5 of 37
Rates Amount Total
Item No. Description of items Unit Quantity
Supply Erection Supply Erection Amount
Supply, installation, testing and commissioning of wall mounted
33011B single phase 230 V , 50Hz air circulating fan of 700-750mm No. 11,340 1,259 20 226800 25180 251980
sweep including all accessories.
Supply, installation, testing and commissioning of air curtain
33011C No. 23,627 1,027 12 283524 12324 295848
single phase 230 V, 1000 mm size.
AC bracket fan 400 mm similar to Havells Swing Remote or
33011D No. 4,762 208 10 47620 2080 49700
equivalent as approved by engineer.
Supply, erection, testing and commissioning of self contained
drinking water cooler 150 liters capacity complete with all
connected standard fittings, accessories etc. and 5 kVA, wall
33012 Each 64,745 13,990 10 647450 139900 787350
mounted, I.C. controlled electronic auto-voltage corrector with
time delay relay, supply and erection of earth electrode and
connection to earthing system etc. as required.
SECTION - C : L.T. SWITCH BOARDS AND FEEDER PILLAR
Supply, installation, testing and commissioning of cubical type,
33013 wall mounted, dust & vermin proof, L.T. switch board of different
capacities
LT switch board 125 Amp comprising of the items indicated as
under
i) incoming MCCB 125A, 4 pole, 35kA, fixed type (Ics=100%Icu) -
1 No
ii) Outgoing MCCB 63A, 25kA, fixed type (Ics=100% Icu) - 4 Nos
iii) Outgoing MCB 40A, 4 pole, 10kA - 4 Nos
(a) No. 95,807 15,048 2 191614 30096 221710
iv) Outgoing MCB 32A, double pole, 10kA - 4 Nos
v) Outgoing MCB 32A, Single pole, 10kA - 4 Nos
vi) Sleeved/Epoxy coated copper bus-bar 250 A in bus bar
Chamber
vii) CT's Indication lights

LT switch board 63 Amp comprising items indicated as under


i) incoming MCCB 63A, 4 pole, 35kA, fixed type (Ics=100%Icu) -
1 No
ii) Outgoing MCCB 40A, 4 pole, 25kA, fixed type (Ics=100%Icu) -
3 Nos
(b) iii) Outgoing MCB double pole, 6-32A, 10kA - 16 Nos No. 87,341 13,719 8 698728 109752 808480
iv) Outgoing MCB Single pole, 6-32A, 10kA - 8 Nos
v)Sleeved/Epoxy coated copper bus-bar 200 A in bus bar
Chamber
vi) Indication lights

Supply, installation, testing & commissioning of weather proof,


33015
LT. feeder pillar of different capacities

Page 6 of 37
Rates Amount Total
Item No. Description of items Unit Quantity
Supply Erection Supply Erection Amount
LT feeder pillar 63Amp comprising of the items indicated as
under ;
(i) incoming MCCB 63A, 4 pole, 35kA, fixed type (Ics=100%Icu) -
1 No ii) Outgoing
MCCB 40A, 4 pole, 25kA, fixed type (Ics=100%Icu) - 4 Nos
33015A iii) Outgoing MCB double pole, 40A, 10kA - 2 Nos No. 99,065 15,557 5 495325 77785 573110
iv) Outgoing MCB Single pole, of 40 A, 10kA- 4 Nos v)
Sleeved/Epoxy coated copper bus-bar 200 A in bus bar Chamber
vi) Indication lights

LT feeder pillar 125 Amp comprising of the items indicated as


under
i) incoming MCCB 125A, 4 pole, 35kA (Ics=100%Icu) - 1 No
ii) Outgoing MCCB 63A, 4 pole, 25kA (Ics=100%Icu) - 4 Nos
iii) Outgoing MCB 40A, 4 pole, 10kA - 4 Nos
iv) Outgoing MCB 32A, DP, 10kA, 4nos
33015B No. 118,233 18,571 1 118233 18571 136804
v) Outgoing MCB Single pole 32A, , 10kA -4nos vi)Modular
digital time switch and 3 phase contactor 63 A - 2 Set
vii) Sleeved/Epoxy coated copper bus-bar 250 A in bus bar
Chamber
viii) Indication lights

LT feeder pillar 250 Amp comprising of the items indicated as


under
i) Incoming MCCB 250 A, FP 35kA (Ics=100%Icu) Fixed Type -
1 No ii) Outgoing
MCCB 125 A, FP 35kA (Ics=100%Icu) Fixed Type - 2 Nos
iii) Outgoing MCCB 63 A, FP 25kA (Ics=100%Icu) Fixed Type -
4 Nos
33015C No. 183,316 28,791 1 183316 28791 212107
iv) Outgoing MCB 40 Amps, FP, 10kA - 4 Nos
v) Outgoing MCB 32 Amps DP 10 KA - 4 Nos 6 Nos
vi) Outgoing MCB Single pole 32A, 10kA -4 Nos vii)
Modular digital time switch and 3 phase contactor 63 A - 2 Set
viii) Sleeved/Epoxy coated copper bus-bar 400 A in bus bar
Chamber
ix) Indication lights
SECTION - D : EXTERNAL ELCTRIFICATION WORKS

Page 7 of 37
Rates Amount Total
Item No. Description of items Unit Quantity
Supply Erection Supply Erection Amount
Supply and erection of different length , swaged type steel
tubular pole , complete with the following :
a) Double door, weather proof MS. Junction box (degree of
protection not less than IP54 ) complete with MCB 6 amps,
copper bus bar for looping 4 - core, 3 nos. LT cables and
clamping with pole, as required
33017 b) Casting of foundation with concrete of M10 grade and
providing muffing up to 300 mm above ground levels, as required
c) Erection of GI pipe class 'B' ISI marked up to junction box for
passing cable.
(payment of G.I. pipe shall be made against the relevant BOQ
item).

7 Meter long pole with canopy type single pipe bracket ( for one
14,880 2,339 20 297600 46780 344380
i) luminary). No.
7 Meter long pole with canopy type double pipe bracket ( for two
15,357 2,413 20 307140 48260 355400
ii) luminaries). No.
Supply and erection of GI pipe - class 'B' ISI marked with
accessories including bends etc. for support of cable with erected
33019
pole/ recessing in wall/ floor/ passing earth strip OR passing
cable as required:
i) 32mm dia Meter 297 48 50 14850 2400 17250
ii) 50 mm dia Meter 458 72 280 128240 20160 148400
iii) 80 mm dia Meter 768 120 280 215040 33600 248640
iv) 100 mm dia Meter 1,082 171 280 302960 47880 350840
v) 150 mm dia Meter 1,760 277 280 492800 77560 570360
Supply, erection, testing & commissioning of control and
distribution panel for colour light signalling supply in 25 kV AC
33020 traction system as per RSDO technical specifications No.
TI/SPC/PSI/CLS/ 0020 (12/02) With A&C slips No. 1 to 4 or
latest, connections as required.
i) For 5-10 kVA AT No. 81,750 12,840 12 981000 154080 1135080
ii) For 25 kVA AT No. 173,933 27,318 2 347866 54636 402502
SECTION - E : POWER SUPPLY DISTRIBUTION ARRANGEMENT
Supply, installation, testing and commissioning of 11 KV/440 V ,
50 HZ , out door type, Delta/Star connected, copper wound,
DYn11, ONAN cooled, power distribution transformer (outdoor
33022
type) conforming to IS:1180 (Energy Efficiency level shall not be
less than–II), complete with all accessories and first filling of oil
as required.
i) 100kVA No. 300,800 54,132 2 601600 108264 709864
ii) 250kVA No. 652,160 87,656 1 652160 87656 739816
iii) 500kVA No. 1,184,000 112,856 1 1184000 112856 1296856

Page 8 of 37
Rates Amount Total
Item No. Description of items Unit Quantity
Supply Erection Supply Erection Amount
Extra for providing fencing/ enclosure for above item as indicated
iv) Kg 90 21 200 18000 4200 22200
in Explanatory Notes.
Extra for construction of foundation for transformer installation as
v) Cu.M 5,727 1,620 20 114540 32400 146940
required.
Supply, erection, testing & commissioning of 3 pole, 11 kV, 400
33023 amps, gang operated switch complete with drop out fuses etc. as No. 34,969 6,399 2 69938 12798 82736
required.
Supply, installation, testing and commissioning of 11kV, 350
33024 MVA 630 A draw out type manually operated, 3 panel HT VCB Set 1,961,495 358,838 1 1961495 358838 2320333
board complete with CTs, PTs etc. as required
Supply, installation, testing and commissioning of , 17 panel LT
switch board comprising of following :
i) incoming ACB 800A, 4 pole , 50kA (manual draw out type ) with
CTR 400/5A - 2 Nos
ii) ACB bus coupler 800A, 4 pole, 50kA (fixed type) - 1 No
iii) On load change over switch 400A, 4 pole, utilisation Cat AC
23 - 1 No.
33025 iv) Outgoing switch fuse unit/ fuse switch unit cat AC 23 (TPN) No. 1,312,349 129,776 0 0 0 0
with HRC fuses (250Amp) - 4 Nos
v) Outgoing switch fuse unit/ fuse switch unit cat AC 23 (TPN)
with HRC fuses 125 Amp -4 Nos.
vi) Outgoing switch fuse unit/ fuse switch unit cat AC 23 (TPN)
with HRC fuses 63 Amp -5 Nos.
vii) Sleeved/ epoxy coated copper bus-bar - 800 A for phase and
400 A for neutral.
Supply, erection, testing and commissioning of 20 panel LT
switch board comprising of following :
i)incoming ACB 800A, 4 pole , 50kA (manual draw out type ) with
CTR 800/5A - 2 Nos
ii) ACB bus coupler 1600A, 4 pole, 50kA (fixed type) - 1 No
iii) On load change over switch 800A, 4 pole, Cat AC 23 - 1 No.
iv) Outgoing switch fuse unit/ fuse switch unit cat AC 23 (TPN)
with HRC fuses 400 Amp) -3 Nos.
33026 v) Outgoing switch fuse unit/ fuse switch unit cat AC 23 (TPN) No. 2,030,415 200,785 0 0 0 0
with HRC fuses 250 Amp) -4 Nos
vi) Outgoing switch fuse unit/ fuse switch unit cat AC 23 (TPN)
with HRC fuses 125 Amp -4 Nos.
vii) Outgoing switch fuse unit/ fuse switch unit cat AC 23 (TPN)
with HRC fuses 63Amp -5 Nos.
viii) Sleeved/ epoxy coated copper bus-bar - 1600A for phase
and 800A for neutral.

Page 9 of 37
Rates Amount Total
Item No. Description of items Unit Quantity
Supply Erection Supply Erection Amount
Supply erection/ fixing of fire extinguishing equipments (ISI)
Marked, Rubber mat (ISI marked), G.I. fire buckets filled with
clean dry sand held on free standing steel stand, first aid box with
medicine (ISI marked) and associated materials, shock treatment
33029 Set 77,944 12,241 0 0 0 0
chart on aluminium frame, schematic diagram of HT/LT
installation & transformer data on white hylem sheet with
aluminium frame & fixing/ providing in the sub station area as per
details in Explanatory notes.
Supply, installation, testing and commissioning of DG set with
33030 acoustic enclosure, complete with AMF panel and all other
accessories and construction of plinth etc.
82.5 kVA DG set with 160amp, 4-pole, MCCB 50 kA
(i) (Ics=100%Icu) , 250amps copper bus-bars, 4 pole contactors 250 Set 690,626 76,736 1 690626 76736 767362
amp.

(ii) 160kVA DG set with 250amp, 4-pole,MCCB 50 kA (Ics=100%Icu) Set 1,136,396 126,266 0 0 0 0
, 400 amps copper bus-bars, 4 pole contactors 400 amp.
250 kVA DG set with 400 amp, 4-pole,MCCB 50 kA
(iii) (Ics=100%Icu), 600 amps copper bus-bars, 4 pole contactors 600 Set 1,704,245 189,360 1 1704245 189360 1893605
amp.
500 kVA DG set with 800 amp, 4-pole ACB (MDO), 800 amps
(iv) Set 3,328,963 369,885 0 0 0 0
copper bus-bars, 4 pole contactors 1000 amp.
Supply, erection, testing and commissioning of 125 kVAR
Automatic power Factor controller panel (capacitor bank)
33031 No. 622,727 61,579 3 1868181 184737 2052918
complete & connection with the main panel as per site
requirement.
SECTION - F : EARTHING ARRANGEMENT
33032 Earthing with 3 meter long, 50mm dia, G.I. pipe class 'B' earth Job
electrode, adding the charcoal or coke and salt, providing
concrete enclosure and MS cover plate with lifting arrangement
3,270 514 120 392400 61680 454080
etc. including connections with 4mm G.I. wire from earth
electrode to switch board / electrical equipment as required.

33033 Earthing with 600mmx600mmx6mm thick G.I earth plate, adding Job
of charcoal or coke and salt, providing concrete enclosure and
3,633 569 4 14532 2276 16808
MS cover plate with lifting arrangement, watering pipe etc. as
required.
33034 Earthing with 600mmx600mmx3mm thick copper earth plate, Job
adding of charcoal or coke and salt, providing concrete
6,417 1,007 4 25668 4028 29696
enclosure and MS cover plate with lifting arrangement, watering
pipe etc. as required.
EARTH CONNECTIONS

Page 10 of 37
Rates Amount Total
Item No. Description of items Unit Quantity
Supply Erection Supply Erection Amount
33035(i) Supply and laying 25mm x6mm G.I. strip at not less than 0.50 Meter
73 13 400 29200 5200 34400
meter below ground or in recess as required.
33035(ii) Supply and laying 40mm x 6mm G.I. strip at not less than 0.50 Meter
120 18 200 24000 3600 27600
meter below ground or in recess as required.
33035(iii) Supplying and fixing 40mm x 5mm copper strip on surface or in Meter
952 150 80 76160 12000 88160
recess or in 50mm dia G.I. pipe as required.
SECTION - G : CABLING

Supply, and laying of 1.1 KV grade LT XLPE insulated armoured,


aluminium conductor cable, making good the damages, end
33036
terminations with aluminium crimping socket/ plugs, provisions of
cable route markers, testing & commissioning etc. as required as
per technical specifications.
i) 2 Core 16 sq.mm Meter 316 156 600 189600 93600 283200
ii) 2 Core 25 sq.mm Meter 366 156 1000 366000 156000 522000
iii) 2 Core 70 sq.mm Meter 625 156 12000 7500000 1872000 9372000
iv) 2 Core 185 sq.mm Meter 1,289 156 400 515600 62400 578000
v) 4 Core 16 sq.mm Meter 409 156 20000 8180000 3120000 11300000
vi) 4.0 Core 35 sq.mm Meter 577 156 16000 9232000 2496000 11728000
vii) 4.0 Core 70 sq.mm Meter 921 156 4000 3684000 624000 4308000
viii) 4.0 Core 120 sq.mm Meter 1,454 156 400 581600 62400 644000
ix) 4.0 Core 185 sq.mm Meter 2,035 156 400 814000 62400 876400
x) 4.0 Core 300 sq.mm Meter 3,298 156 400 1319200 62400 1381600
xi) Single Core 400 sq.mm Meter 1,060 156 400 424000 62400 486400
SECTION - H : ELECTRIFICATION BY HIGH MASTS
Supply, erection, testing & commissioning of hot dipped
galvanised , high mast system complete with all accessories,
foundation, carriage arrangement suitable for LED luminaries
33037 symmetrically arranged & control gear boxes and lighting finial
etc., twin dome aviation obstruction lights, control panel, multi
core flexible copper conductor cable, connection to earthing
system and fencing panel as per requirement.
(i) 16 Meter high mast system, suitable for 6 to 9 nos luminaires. Job 281,916 44,450 2 563832 88900 652732
(ii) 12 Meter high mast system, suitable for 6 to 9 nos luminaires. Job 245,087 40,640 3 735261 121920 857181
(iii) 25 Meter high mast system suitable for 9 to 12 nos luminaires Job 430,540 48,260 1 430540 48260 478800
section - I : LAYING OF 11 KV / 33 KV CABLES
Supply and laying of following sizes XLPE (E) insulated,
33038
armoured, aluminium conductor HT cable.
(i) 11 kV, 3 Core 70sq mm Meter 896 228 400 358400 91200 449600
(ii) 11 kV, 3 Core 185 sq mm Meter 1,590 228 1200 1908000 273600 2181600
(iii) 33 kV, 3 Core 300 sq mm Meter 2,219 228 400 887600 91200 978800
(iv) 33 kV, 3 Core 400 sq mm Meter 2,789 228 400 1115600 91200 1206800

Page 11 of 37
Rates Amount Total
Item No. Description of items Unit Quantity
Supply Erection Supply Erection Amount
Supply and erection of RFID based electronic Cable/pipe marker Nos
of reputed make suitable to work upto 1.5m depth, min dia of 22
CMs, having inbuilt GPS module for storing GPS coordinates,
each marker identification with 10 digits Hexadecimal Code,
33039 (i) 134.0 KHZ frequency with self generated power source having 2,100 50 2 4200 100 4300
capability to receive signals and transmit back, working life >= 40
yrs. Marker to be similar to Smart RFID marker SM 1500 or
superior as approved by Engineer.

33039 (ii) Supply and erection of MS cable route marker No. 384 18 40 15360 720 16080

Supply of outdoor type, heat shrinkable, end termination kit,


33040 suitable for following cable sizes XLPE(E) insulated, armoured
aluminium conductor cable and making termination, connections
with overhead conductor, testing and commissioning etc.
(i) 3 core 11 kV 70 to 185 sq mm No. 12,809 2,012 4 51236 8048 59284
(ii) 3 core 33 kV 240 to 400 sq mm No. 40,174 3,973 4 160696 15892 176588
Supply, Testing and commissioning of RFID Marker locator 1.5m
Depth Range, capable of acquiring and storing min 8000 RFID
marker records, having built in GPS Module for logging GPS
coordinates and audio guidance for operator to navigate to
33041 Nos 313,000 3,400 0 0 0 0
locations of RFID markers, LCD/LED Display, data port to allow
data output to PC with marker database software . Similar to
Smart RFID marker locator Energy/SML or superior as
approved by Engineer.
Supply erection of pre-stressed, cement concrete (PSCC) double
pole structure 9-11 meters long suitable for 330KG working load
with top section 200mm x 105mm and bottom section 410 mm x
140 mm complete with 4 nos. channel cross arms & 2 nos cross
33042(i) No. 77390 7652 0 0 0 0
bracing angles, clamps, bolt, nuts, galvanized stay set, anti
climbing devices, Danger plates on the erected pole galvanised
stay rod, casting of foundation for poles & stay etc. as required.

Supply of Material fabrication and erection of 9-11 m long 'H' pole


(Double pole) with M.S Beam 150mm x 150mm, 4 nos. channel
33042(ii) cross arms & 2 nos cross bracing angles, clamps, bolts, nuts, No. 86717 21679 2 173434 43358 216792
galvanized stay set, anti climbing device, Danger plates on the
erected pole galvanised stay rod, casting of foundation for poles
& stay and painting etc. as per concerned SEB requirements.

Page 12 of 37
Rates Amount Total
Item No. Description of items Unit Quantity
Supply Erection Supply Erection Amount
Supply and erection of 11 kV Porcelain Disc insulator complete
with galvanised iron hardware etc. including terminating with
33043 No. 1,395 138 8 11160 1104 12264
11kV / 33 kV overhead conductor and dismantling, handing over
works as required.
Supply and laying of HDPE pipe DWC/Split DWC type, of size
200 mm outer dia Grade PN4, PE80, ISI marked (either single
piece of full round or two half round split pieces set), under the
33044(a) Meter 348 22 40 13920 880 14800
Railway track/ road etc. digging of trench and back filling with
excavated earth after laying of pipe and making good the
damages as required.
Supply and laying of HDPE pipe DWC/Split DWC type, of size
200 mm outer dia,Grade PN4, PE80, ISI marked (either single
33044(b) piece or full round of two half round split pieces set), under the Meter 348 818 40 13920 32720 46640
Railway track/ road etc. with trench less method and making
good the damages as required.
Supply and laying of HDPE pipe DWC/Split DWC type, of size
63 mm outer dia, Grade PN4, PE80, ISI marked (either single
piece of full round or two half round split pieces set), under the
33044 (c) Meter 78 22 120 9360 2640 12000
Railway track/ road etc. digging of trench and back filling with
excavated earth after laying of pipe and making good the
damages as required.
Supply and laying of HDPE pipe DWC/Split DWC type, of size 63
mm outer dia, Grade PN4, PE80, ISI marked (either single piece
33044 (d) or full round of two half round split pieces set), under the Railway Meter 78 818 120 9360 98160 107520
track/ road etc. with trench less method and making good the
damages as required.
Supply and laying of HDPE pipe DWC/Split DWC type, of size
110 mm outer dia, Grade PN4, PE80, ISI marked (either single
piece of full round or two half round split pieces set), under the
33044 (e) 314 22 200 62800 4400 67200
Railway track/ road etc. digging of trench and back filling with
excavated earth after laying of pipe and making good the
damages as required.
Supply and laying of HDPE pipe DWC/Split DWC type, of size
110 mm outer dia, Grade PN4, PE80, ISI marked (either single
33044(f) piece or full round of two half round split pieces set), under the 314 818 200 62800 163600 226400
Railway track/ road etc. with trench less method and making
good the damages as required.
Supply and laying of HDPE pipe DWC/Split DWC type, of size
160 mm outer dia, Grade PN4, PE80, ISI marked (either single
piece of full round or two half round split pieces set), under the
33044(g) 655 22 200 131000 4400 135400
Railway track/ road etc. digging of trench and back filling with
excavated earth after laying of pipe and making good the
damages as required.

Page 13 of 37
Rates Amount Total
Item No. Description of items Unit Quantity
Supply Erection Supply Erection Amount
Supply and laying of HDPE pipe DWC/Split DWC type, of size
160 mm outer dia Grade PN4, PE80, ISI marked (either single
33044(h) piece or full round of two half round split pieces set), under the 655 818 200 131000 163600 294600
Railway track/ road etc. with trench less method and making
good the damages as required.
33044 (i) Extra on 33044(a), (c), (e), (g) for hard soil/soft rock locations. Meter 11 40 0 440 440
33044 (j) Extra on 33044(b), (d), (f), (h) for hard soil/soft rock locations. Meter 409 40 0 16360 16360
SECTION - J : PROVISION OF PUMPS

Supply, installation, testing and commissioning of submersible


pump set suitable to operate on 3 phase, 415V, 50 Hz AC supply
along with control panel etc. complete for supplying water at
33045 suitable discharge and head as per site requirement.
(i) 7.5 HP pump set Job 90,811 8,979 1 90811 8979 99790
(ii) 5 HP pump set Job 83,163 8,225 2 166326 16450 182776
SECTION - K : MISC. WORK

Co- ordination/ liasoning and chasing with State Utility Company


for availing new electrical connection/ augmentation of
sanctioned load at stations, level crossings etc. including
applying for load, collection of estimates for loads, modification of Each
33046 0 9,690 6 0 58140 58140
power line crossings, arranging payment from RVNL, depositing Location
payment to State Utility Company, arranging release of load &
other related works, payment to be made to SEB for new
connection, load augmentation, modification of power line
crossings etc. shall be made by RVNL.

Design and preparation of working & completion drawings of all


HT/LT electrical installations of the project section where work is
carried out such as platform lighting, internal electrification of
33047 Job 0 199,710 2 0 399420 399420
staff quarters, level crossings, station building, offices, power line
crossings, power supply distribution arrangements of stations /
sub-stations, electrification of sub-station buildings etc &
approval from the competent authority.

Page 14 of 37
Rates Amount Total
Item No. Description of items Unit Quantity
Supply Erection Supply Erection Amount
Conducting check survey of the complete project section to
compile details of all the existing LT, HT, and EHT Power line
Electrical overhead and underground power/telegraphic/other
lines running along or across the track and recording
measurements of horizontal distances of structures from the
existing & proposed tracks, vertical clearance of conductors &
guard wire from rail level, angle of crossings w.r.t. track, height
and type of towers/poles and preparation of lists as below:
33048 i) List of Overhead/Underground Crossings infringing and Job 0 157,665 1 0 157665 157665
requiring modification. Proposed modification may also be
indicated.
ii) List of Overhead/Underground Parallel Alignments infringing
and requiring modification.Proposed modification may also be
indicated.
iii) List of overhead/underground crossings/parallel Alignments in
conformity with the Rules/regulations and not requiring
modification.

Supply, installation, testing & commissioning of outdoor type,


single side /Double side Glow sign boards/Pictorial signage
boards with suspension/side mounting/wall mounting type
33049 Sq. Feet 405 61 1200 486000 73200 559200
arrangements as required. (Payment for Double sided glow sign
board shall be made @ 150% of the rate of single sided glow
sign boards)

Supply, installation, testing & commissioning of Silicon rectifier


battery charging set conforming to relevant IS (latest), suitable for
33050 No. 135,782 21,326 2 271564 42652 314216
operation on 3 phase 4 wire, 415 Volts AC supply system, 125
Volts to 150 Volts DC output, 200 Amps capacity as per Tech
Specification including earthing, etc as required.
Fabrication, supply, installation, testing and commissioning of
110 Volts battery charging point suitable for operation on 150
33051 Job 4,910 772 12 58920 9264 68184
Volts DC supply system including erection on MS channel,
foundation etc complete.
Fabrication, supply, installation, testing and commissioning of pre-
33052 Job 13,287 2,087 12 159444 25044 184488
cooling point as per details given in explanatory notes.
SECTION - N : DISMANTLING WORKS

Page 15 of 37
Rates Amount Total
Item No. Description of items Unit Quantity
Supply Erection Supply Erection Amount
Dismantling of wiring installations of buildings, sheds, quarters,
etc. complete with luminaries, fans, distribution boards, LT
Each
Panels and associated cables including accountal, stocking,
33053 Station/G 0 9,189 12 0 110268 110268
transportation and handing over of released materials to
ate lodge
Electrical department as directed by the Engineer and making
temporary arrangements if required.
Dismantling of erected pole/overhead conductor, GI wire, cross
arm brackets, insulators, stay, luminary etc including accountal,
33054 (i) stocking, and handing over the released materials to railway's No. 0 919 12 0 11028 11028
authorized official as instructed by the Engineer and making
temporary arrangements if required.
Dismantling of sub-station equipments such as transformers, DG
Set, HT & LT Panels, cables etc at site including transporting,
33054 (ii) stocking and handing over to Electrical department as instructed Job 0 18,377 0 0 0 0
by the Engineer and making temporary arrangements if required.

Provision of temporary lighting arrangement with 1x40 watt F.L


tube light/CFL/LED/Halogen/MH/flood light fitting and
pedestal/ceiling fans, desert coolers in temporary tents, buildings,
goomties, on tracks, in yard area including wiring, cabling,
earthing etc as directed by the Engineer and as per site
33055 (i) requirement for pre/post/during non-interlocking period, including Per day 0 27,565 60 0 1653900 1653900
providing stand by D.G set of suitable capacity and deployment
of staff for operation of DG set as per site requirement.
NOTE: Normal power supply may be used, up to sanctioned
load, if surplus available at site.

Extra for operation and maintenance of temporary wiring


33055 (ii) installations, replacement of consumables, supply of diesel oil, Per day 0 5,470 6 0 32820 32820
lub oil etc for operation of DG set etc.
Supply, installation, testing and commissioning of AC unit,
complete with LCD display cordless remote, min 3 star energy
33056 rating, suitable for 1-Phase, 230 volts +-10% AC supply including 0 0 0
supply & installation of suitable rating, wall mounted, IC
controlled electronic auto voltage corrector.

Page 16 of 37
Rates Amount Total
Item No. Description of items Unit Quantity
Supply Erection Supply Erection Amount
(a) 2.0 Tonne window type AC No. 48,538 3,675 4 194152 14700 208852
(b) 1.5 Tonne window type AC(minimum 5-star rating) No. 37,596 3,675 4 150384 14700 165084
(c) 2.0 Tonne split type AC, inverter type(minimum 3-star rating) No. 65,582 3,675 4 262328 14700 277028
(d) 1.5 Tonne split type AC, inverter type No. 46,789 3,675 4 187156 14700 201856
Supply & erection of G.I Octagonal pole including digging of pit,
making foundation with cement, sand & concrete in ratio 1:2:6,
33057
muffing, accommodating G.I pipe in foundation for cable loop-in-
loop out of suitable size as required
i) 5 meters long No. 11,830 2,904 400 4732000 1161600 5893600
ii) 7 meters long No. 16,399 4,026 80 1311920 322080 1634000
Additional cost of single arm bracket suitable for street light
iii) 493 122 400 197200 48800 246000
fixture No.
Additional cost of double arm bracket suitable for street light
iv) 585 145 80 46800 11600 58400
fixture No.
Supply installation testing & commissioning of cubical type mast
33058 mounted, dust & vermin proof, LT control switch board 0 0 0
conforming to IS:8623 (latest version), complete.

i) a) with TPN MCCB 32A, 35 KA, fixed type ( Ics=100% Icu)-1 No 14,960 3,672 40 598400 146880 745280
b) copper busbars 200A ( for 5 KVA AT) No.

ii) a) with TPN MCCB 63A, 35 KA, fixed type ( Ics=100% Icu)-1 No 17,521 4,300 12 210252 51600 261852
b) copper busbars 200A ( for 10 KVA AT) No.

iii) a) with TPN MCCB 150A, 35 KA, fixed type ( Ics=100% Icu)-1 No 20,817 5,108 1 20817 5108 25925
b) copper busbars 300A ( for 25 KVA AT) No.
Section - P (Misc. Items)
Supply installation testing & commissioning of 15W LED Solar
Street light system with 6/7 m pole GI complete with all
33059 54,907 3,940 12 658884 47280 706164
accessories as per RDSO specifications RDSO/PE
/SPEC/PS/0093-2008 (Rev.0) Amend-3 or latest. No.

Page 17 of 37
Rates Amount Total
Item No. Description of items Unit Quantity
Supply Erection Supply Erection Amount
Supply erection testing & commissioning of FLAT PLATE
COLLECTOR BASED type solar water heating system of 300
liters capacity complete with solar collector, insulated tank,
33060 55,821 13,956 1 55821 13956 69777
supporting stand, connecting pipes, instrumentation etc including
tapping of water supply from the existing arrangement/system as
required. Job
Design, supply, erection, and commissioning of grid connected
solar power plant consisting of solar panels, PCU mounting
33061 KWp 60,000 6,125 64 3840000 392000 4232000
structures and all other associated equipments as per
RDSO/PE/SPEC/PS/0092-2008 (Rev.0) with latest amendment.
Supply & erection of perforated cable tray size 75 x 75x350 mm,
33062 manufactured with 2 mm thick G.I Sheet holding on G.I angle Meter 706 177 52 36712 9204 45916
50x50x6 mm for supprot as required.
Supply and installation of Furniture set for substation control
33063 (i) Set 81,442 0 0 0 0 0
room.
33063 (ii) Supply and installation of Ladder set. Set 139,359 0 0 0 0 0
Supply and erection of all types of galvanised Steel
33064 StructuresSmall Parts Steel etc for the exclusive work in the field MT 103,710 3,485 0 0 0 0
of General Electrical Service.
Supply, erection, testing and commissioning of 33 KV, 1560 MVA
3 pole type, VCB panel out door type, breaking capacity 1560A ,
33065 with terminal connector suitable for DOG ACSR conductor, Nos 855,509.00 95,056.00 0 0 0 0
spring operated motor mechanism , with all standard essential
accessories and post /support insulators as required .
Supply erection testing and commissioning of control & relay
panel for 33 KV VCB (triple pole) and 33/11KV 3000 KVA
transformers with necessary numerical relays and indicating
33066 Nos 285,169.00 31,685.00 0 0 0 0
devices including measurement of energy and MD. This shall
include outdoor CT & PT with post insulators etc including control
cables as required for above functions.
Supply erection testing and commissioning of 33 KV/42 KV peak
33067 non linear resistor type station class Lightening arrestor, with Set 57,033.00 6,337.00 0 0 0 0
surge monitor complete with all accessories.

Page 18 of 37
Rates Amount Total
Item No. Description of items Unit Quantity
Supply Erection Supply Erection Amount
Supply erection testing and commissioning of 33 KV, 400 A
outdoor type triple pole horizontal mounting rotating type double
33068 Set 33269 3697 0 0 0 0
air break gang operated Isolator with all standard accessories
and post insulators as required.
Supply erection testing and commissioning of 33 KV Bus bar
made of ACSR DOG conductor of size 16/4.72+7/1.57 mm
33069 Mtr 66 8 0 0 0 0
including Disc type , post type insulators, jumper connection with
suitable connector ,clamps etc as required.
Supply erection testing and commissioning of 33 KV/11KV 3-
phase 3000 KVA ONAN outdoor type transformer with off load
33070 Nos 5,755,884 28,026 0 0 0 0
tap changer(+5% to -10% with 2.5% step size) with bushing
termination on 33 KV and cable box termination on 11 KV side.
Supply erection testing and commissioning of LED signage
33071 Sqft 5749 80 459920 0 459920
(similar to neon sign) M/s Glowz or similar
Supply erection testing and commissioning of LED edge lit
33072 Sqft 1695 40 67800 0 67800
signage board.
Supply and erection of stay set with CC foundation in ratio
33073 1:3:6, stay rod , stay tightner, stay insulator , GI wire 7/8 SWG, set 1835 0 0 0 0
thimble and other fixing accessories as required .
Supply, erection and commissioning of hydraulic elevating
platform (articulated type-02 boom ) having working height of 9.5
mtr, outer reach of 3.7 mtrs, safe working load of 120kg , slewing
33074 range of 300 degree, fibreglass cage of required size to facilitate Nos 1,100,900 0 0 0 0
fixing of fittings and maintenance of electric poles suitably
mounted on TATA ACE, HT BS–IV chassis and engine
complete with all accessories.
Supply and installation of Refrigerator minimum 270 Ltr capacity,
33075 double door, min 3 star rating suitable for 230 V AC supply with Nos 18,161 1 18161 0 18161
stabilizer of suitable rating.
Total ( Schedule 33000) 73,752,404.00 21,029,568.00 94,781,972.00

Page 19 of 37
Rates Amount Total
Item No. Description of items Unit Quantity
Supply Erection Supply Erection Amount
Non Schedule Items
Providing Road Vehicle mentioned below for the use of
Engineer/Employer as per the Conditions mentioned in Clause 3.4.3, i.e
NS-1
3.4.3.1 to 3.4.3.3 of Chapter 3 (Site Facilities for the Employer and the
Engineer) of Section 5 Work's Requirement) of Tender Documents.
(a) Tavera, Innova or similar nos. 53199 14 744786 744786
(b) Tata Sumo, Bolero or similar nos. 45776 72 3295872 3295872
Extra for running and maintenance of every additional km over and
(c) Per Km 12.38 2400 29712 29712
above 4000 kms as specified in item NS-1(a)
Extra for running and maintenance of every additional km over and
(d) Per Km 9.9 4000 39600 39600
above 4000 kms as specified in item NS-1(b)
Total ( Schedule 33000)NS 10,877,436.00 4,109,970.00
Grand Total 98,891,942.00

Page 20 of 37
ELECTRICAL GENERAL SERVICES WORKS
SCHEDULE - 33000 ELECTRICAL GENERAL SERVICES WORKS
Bill of Quantities General Electrical Works in connection With Railway Electrification of Phephna-Indara, Mau-Shahganj (Excluding Indara-Mau) (150.28KM)
Package -2 for Mau - Shahganj (Excl Mau)Section of Varanasi Division of N E Railway.
This schedule shall be read in conjunction with its Explanatory Notes and Technical Specifications for detailed description for various items included therein
Rates Amount Total
Item No. Description of items Unit Quantity
Supply Erection Supply Erection Amount
Electrification of staff quarter complete with point wirings, circuit
wirings, sub main wirings etc. with Fire Retardant (FR) PVC
insulated, multistranded, copper conductor, single core cable on
surface/ in recessed PVC conduits, along with provision of
33001 luminaries with lamps, call bells, ceiling & exhaust fans,
distribution boards, loose wire box, geyser, energy meters in
M.S. box including earthing with G.I. pipe electrode etc. as per
scale of fittings, and cable sizes, nos. of points permissible in
each circuit and sub main/s etc. for each type of quarter as
indicated in Explanatory Notes.
i) Type - I quarter Each 0 40,093 3 0 120279 120279
ii) Type - II quarter Each 0 42,172 12 0 506064 506064
iii) Type - III quarter Each 0 52,936 6 0 317616 317616
iv) Type - IV quarter Each 0 97,935 3 0 293805 293805
v) Type - V quarter Each 0 134,403 0 0 0 0
Extra for stair case light point controlled with two nos. two way
vi) Each 0 862 30 0 25860 25860
switches
ELECTRIFICATION OF GATE MAN LODGES AT LEVEL CROSSINGS
Electrification of gate man lodge complete with point wirings,
circuit wirings etc. with Fire Retardant (FR) PVC insulated,
multistranded, copper conductor, single core cable on surface/in
recessed PVC conduits, including provision of luminaries with
33002 Each 0 24,946 33 0 823218 823218
lamps, ceiling fan, distribution board, earthing with G.I. pipe
electrode etc. as per scale of fittings, cable sizes, nos. of points
permissible in each circuit and sub mains as indicated in
Explanatory Notes.
ELECTRIFICATION OF SERVICE BUILDINGS, PASSENGER SHELTER, SHEDS, PUMP HOUSE, SUB STATION BUILDINGS, OFFICES ETC AND ADDITIONAL
REQUIREMENT OF POINTS IN QUARTERS, LC GATES ETC.
Wiring for light/ ceiling fan/exhaust fan/call bell/light plug/ group
etc. points including circuit wiring, sub main wiring with Fire
Retardant (FR), PVC insulated, multistranded, copper conductor,
single core cable on surface/in recessed PVC conduits,
33003 (i) Point 0 1,556 1500 0 2334000 2334000
distribution boards, sub distribution boards, earthing etc. as
required. Wiring shall be done as per sizes of cables, no. of
points permissible in each circuit and sub mains as indicated in
Explanatory Notes.

Page 21 of 38
Wiring for power plug point including circuit wiring, sub main
wiring with Fire Retardant (FR), PVC insulated, multistranded,
copper conductor, single core cable on surface/in recessed PVC
33003 (ii) conduits, distribution boards, sub distribution boards, earthing Point 0 2,857 300 0 857100 857100
with G.I. pipe electrode etc. as required. Wiring shall be done as
per sizes of cables, no. of points permissible in each circuit and
sub mains as indicated in Explanatory Notes.
Extra for provision of industrial type iron clad plug socket with
33003 (iii) Point 0 780 39 0 30420 30420
32A DP MCB in M.S. Box.
Multiplug points (power strip 3 no. 6A socket controlled by 16 A
33003 (iv) switch) similar to Legrand cat no. 6745.48 OR as approved by No. 1,857 92 12 22284 1104 23388
engineer.
Supply of Light meter measuring up to 200000 lux with battery
33004 and carry case (HTC instruments make ref LX-103 or equivalent Nos 1,766 6 10596 0 10596
as approved by engineer)
SECTION - B : PROVISION OF LUMINARIES, FANS, WATER COOLERS ETC
Supply, installation, testing and commissioning of light sensitive
street light controller, 25 kW for street light/ High mast complete
with infrared sensors, contactors and MCB, terminal board etc.
33006 No. 46,180 2,008 9 415620 18072 433692
for 25 KW load, Operative Voltage 185-275 V AC. Make: Bajaj
Energy pack or equivalent as approved by Engineer.

Supply, installation, testing and commissioning of 230V A. C


ceiling fan 1400mm with double ball bearing and suitable
33008 capacitor complete with wiring with 1.5 sq.mm FR PVC insulated No. 2,339 367 360 842040 132120 974160
copper conductor, single/ three core cable as instructed etc. as
required.
33008A Supply and erection of 1200mm BLDC fan with remote 2,478 157 180 446040 28260 474300

Supply and fixing of stepped type, electronic fan regulator with


33009 suitable rating for the C/ Fan on the existing phenolic laminated No. 439 98 180 79020 17640 96660
sheet cover plate/ modular plate of switch box, including
connections, testing and commissioning as required.
Supplying, installation, testing and commissioning of 11-15 W
33010 A No. 230 36 60 13800 2160 15960
LED lamp as approved by Engineer.
Supply, erection, testing and commissioning of Recessed type
LED luminaries for 2x2 Grid ceiling, powder coated, CRCA
33010B housing, high efficiency reflector & diffuser cover, system No. 4,466 819 18 80388 14742 95130
wattage 35-45W suitable to work on 220-240V AC supply.

Supply, erection, testing and commissioning of LED down lighter


having pressure die cast aluminium housing white powder
33010C No. 1,683 608 12 20196 7296 27492
coated and acrylic cover, system wattage 14-16w suitable to
work on 220-240V AC supply.

Page 22 of 38
Supply, erection, testing and commissioning of LED Street light
fitting ,pressure di-cast aluminium housing with suitable cover,
33010D
suitable to work on 220-240V AC supply with system wattage as
under :
(i) Fitting 43-48 W No. 6,503 547 45 292635 24615 317250
(ii) Fitting 35-40 W No. 5,550 547 300 1665000 164100 1829100
(iii) Fitting 70-74 W No. 10,067 547 60 604020 32820 636840
(iv)Fitting 23-27 W No. 2,458 548 60 147480 32880 180360
Supply and installation of surface /wall mounted, LED batten
type light fitting complete with LED Lamp with system wattage 18-
33010E No. 1,422 132 600 853200 79200 932400
22w suitable to work on 220-240V AC supply as approved by
engineer.
Supply and Installation of 7 watts sleek LED mirror light with
diffuser and Led lamp similar to Crompton Greaves Ltd Model
33010 F No. 1,964 35 30 58920 1050 59970
LINNET LCL-07-CDL complete or superior as approved by
Engineer.
Supply, erection, testing and commissioning of LED flood light
fitting, pre die cast aluminium, IP-65 with high power LED as
33010G No. 23,022 655 12 276264 7860 284124
light source with system wattage 140-150 w suitable to work on
220-240V AC supply as approved by Engineer.
Supply, erection, testing and commissioning of LED flood light
fittings pre die cast aluminium IP-65 with high power LED as light
33010H No. 32,463 655 12 389556 7860 397416
source with system wattage 200-210 w suitable to work on 220-
240V AC supply as approved by Engineer.
Supply, erection, testing and commissioning of LED flood light
fittings pre die cast aluminium IP-65 with high power LED as light
3301 I No. 15,792 655 12 189504 7860 197364
source with system wattage 90-110 w suitable to work on 220-
240V AC supply as approved by Engineer.
Supply, erection, testing, commissioning of exhaust fan suitable
for 1- phase, 230 Volts, AC supply system complete with
capacitor, louver shutters, grouting bolts with nuts, making
33011A opening/ modification in the wall to suit the size of the fan,
making good the damages, connections with 1.5sq. mm FR,
PVC insulated, multi stranded copper conductor, single core/
three cable as instructed, earthing etc. as required.
(i) AC exhaust fan 300 mm 900 rpm with/ without louver shutters. No. 3,470 543 15 52050 8145 60195
(ii) AC exhaust fan 150 mm with louver shutters. No. 1,930 415 15 28950 6225 35175
(iii) AC exhaust fan 450 mm with/ without louver shutters. No. 8,326 415 15 124890 6225 131115
Supply, installation, testing and commissioning of wall mounted
33011B single phase 230 V , 50Hz air circulating fan of 700-750mm No. 11,340 1,259 30 340200 37770 377970
sweep including all accessories.
Supply, installation, testing and commissioning of air curtain
33011C No. 23,627 1,027 18 425286 18486 443772
single phase 230 V, 1000 mm size.
AC bracket fan 400 mm similar to Havells Swing Remote or
33011D No. 4,762 208 15 71430 3120 74550
equivalent as approved by engineer.

Page 23 of 38
Supply, erection, testing and commissioning of self contained
drinking water cooler 150 liters capacity complete with all
connected standard fittings, accessories etc. and 5 kVA, wall
33012 Each 64,745 13,990 15 971175 209850 1181025
mounted, I.C. controlled electronic auto-voltage corrector with
time delay relay, supply and erection of earth electrode and
connection to earthing system etc. as required.
SECTION - C : L.T. SWITCH BOARDS AND FEEDER PILLAR
Supply, installation, testing and commissioning of cubical type,
33013 wall mounted, dust & vermin proof, L.T. switch board of different
capacities
LT switch board 125 Amp comprising of the items indicated as
under
i) incoming MCCB 125A, 4 pole, 35kA, fixed type (Ics=100%Icu) -
1 No
ii) Outgoing MCCB 63A, 25kA, fixed type (Ics=100% Icu) - 4 Nos
(a) iii) Outgoing MCB 40A, 4 pole, 10kA - 4 Nos No. 95,807 15,048 4 383228 60192 443420
iv) Outgoing MCB 32A, double pole, 10kA - 4 Nos
v) Outgoing MCB 32A, Single pole, 10kA - 4 Nos
vi) Sleeved/Epoxy coated copper bus-bar 250 A in bus bar
Chamber
vii) CT's Indication lights

LT switch board 63 Amp comprising items indicated as under


i) incoming MCCB 63A, 4 pole, 35kA, fixed type (Ics=100%Icu) -
1 No
ii) Outgoing MCCB 40A, 4 pole, 25kA, fixed type (Ics=100%Icu) -
3 Nos
(b) iii) Outgoing MCB double pole, 6-32A, 10kA - 16 Nos No. 87,341 13,719 10 873410 137190 1010600
iv) Outgoing MCB Single pole, 6-32A, 10kA - 8 Nos
v)Sleeved/Epoxy coated copper bus-bar 200 A in bus bar
Chamber
vi) Indication lights

Supply, installation, testing & commissioning of weather proof,


33015
LT. feeder pillar of different capacities
LT feeder pillar 63Amp comprising of the items indicated as
under ;
(i) incoming MCCB 63A, 4 pole, 35kA, fixed type (Ics=100%Icu) -
1 No ii) Outgoing
MCCB 40A, 4 pole, 25kA, fixed type (Ics=100%Icu) - 4 Nos
33015A No. 99,065 15,557 7 693455 108899 802354
iii) Outgoing MCB double pole, 40A, 10kA - 2 Nos
iv) Outgoing MCB Single pole, of 40 A, 10kA- 4 Nos v)
Sleeved/Epoxy coated copper bus-bar 200 A in bus bar
Chamber
vi) Indication lights

Page 24 of 38
LT feeder pillar 125 Amp comprising of the items indicated as
under
i) incoming MCCB 125A, 4 pole, 35kA (Ics=100%Icu) - 1 No
ii) Outgoing MCCB 63A, 4 pole, 25kA (Ics=100%Icu) - 4 Nos
iii) Outgoing MCB 40A, 4 pole, 10kA - 4 Nos
33015B iv) Outgoing MCB 32A, DP, 10kA, 4nos No. 118,233 18,571 1 118233 18571 136804
v) Outgoing MCB Single pole 32A, , 10kA -4nos
vi)Modular digital time switch and 3 phase contactor 63 A - 2
Set
vii) Sleeved/Epoxy coated copper bus-bar 250 A in bus bar
Chamber
viii) Indication lights
LT feeder pillar 250 Amp comprising of the items indicated as
under
i) Incoming MCCB 250 A, FP 35kA (Ics=100%Icu) Fixed Type -
1 No ii) Outgoing
MCCB 125 A, FP 35kA (Ics=100%Icu) Fixed Type - 2 Nos
iii) Outgoing MCCB 63 A, FP 25kA (Ics=100%Icu) Fixed Type -
4 Nos 183,316 28,791 1 183316 28791 212107
33015C No.
iv) Outgoing MCB 40 Amps, FP, 10kA - 4 Nos
v) Outgoing MCB 32 Amps DP 10 KA - 4 Nos 6 Nos
vi) Outgoing MCB Single pole 32A, 10kA -4 Nos vii)
Modular digital time switch and 3 phase contactor 63 A - 2 Set
viii) Sleeved/Epoxy coated copper bus-bar 400 A in bus bar
Chamber
ix) Indication lights
SECTION - D : EXTERNAL ELCTRIFICATION WORKS
Supply and erection of different length , swaged type steel
tubular pole , complete with the following :
a) Double door, weather proof MS. Junction box (degree of
protection not less than IP54 ) complete with MCB 6 amps,
copper bus bar for looping 4 - core, 3 nos. LT cables and
clamping with pole, as required
33017 b) Casting of foundation with concrete of M10 grade and
providing muffing up to 300 mm above ground levels, as
required
c) Erection of GI pipe class 'B' ISI marked up to junction box for
passing cable.
(payment of G.I. pipe shall be made against the relevant BOQ
item).
7 Meter long pole with canopy type single pipe bracket ( for one
14,880 2,339 30 446400 70170 516570
i) luminary). No.
7 Meter long pole with canopy type double pipe bracket ( for two
15,357 2,413 30 460710 72390 533100
ii) luminaries). No.

Page 25 of 38
Supply and erection of GI pipe - class 'B' ISI marked with
accessories including bends etc. for support of cable with
33019
erected pole/ recessing in wall/ floor/ passing earth strip OR
passing cable as required:
i) 32mm dia Meter 297 48 75 22275 3600 25875
ii) 50 mm dia Meter 458 72 420 192360 30240 222600
iii) 80 mm dia Meter 768 120 420 322560 50400 372960
iv) 100 mm dia Meter 1,082 171 420 454440 71820 526260
v) 150 mm dia Meter 1,760 277 420 739200 116340 855540
Supply, erection, testing & commissioning of control and
distribution panel for colour light signalling supply in 25 kV AC
33020 traction system as per RSDO technical specifications No.
TI/SPC/PSI/CLS/ 0020 (12/02) With A&C slips No. 1 to 4 or
latest, connections as required.
i) For 5-10 kVA AT No. 81,750 12,840 18 1471500 231120 1702620
ii) For 25 kVA AT No. 173,933 27,318 3 521799 81954 603753
SECTION - E : POWER SUPPLY DISTRIBUTION ARRANGEMENT
Supply, installation, testing and commissioning of 11 KV/440 V ,
50 HZ , out door type, Delta/Star connected, copper wound,
DYn11, ONAN cooled, power distribution transformer (outdoor
33022 type) conforming to IS:1180 (Energy Efficiency level shall not be
less than–II), complete with all accessories and first filling of oil
as required.
i) 100kVA No. 300,800 54,132 2 601600 108264 709864
ii) 250kVA No. 652,160 87,656 1 652160 87656 739816
iii) 500kVA No. 1,184,000 112,856 1 1184000 112856 1296856
Extra for providing fencing/ enclosure for above item as
iv) Kg 90 21 300 27000 6300 33300
indicated in Explanatory Notes.
Extra for construction of foundation for transformer installation as
v) Cu.M 5,727 1,620 30 171810 48600 220410
required.
Supply, erection, testing & commissioning of 3 pole, 11 kV, 400
33023 amps, gang operated switch complete with drop out fuses etc. as No. 34,969 6,399 2 69938 12798 82736
required.
Supply, installation, testing and commissioning of 11kV, 350
33024 MVA 630 A draw out type manually operated, 3 panel HT VCB Set 1,961,495 358,838 1 1961495 358838 2320333
board complete with CTs, PTs etc. as required

Page 26 of 38
Supply, installation, testing and commissioning of , 17 panel LT
switch board comprising of following :
i) incoming ACB 800A, 4 pole , 50kA (manual draw out type )
with CTR 400/5A - 2 Nos
ii) ACB bus coupler 800A, 4 pole, 50kA (fixed type) - 1 No
iii) On load change over switch 400A, 4 pole, utilisation Cat AC
23 - 1 No.
33025 iv) Outgoing switch fuse unit/ fuse switch unit cat AC 23 (TPN) No. 1,312,349 129,776 1 1312349 129776 1442125
with HRC fuses (250Amp) - 4 Nos
v) Outgoing switch fuse unit/ fuse switch unit cat AC 23 (TPN)
with HRC fuses 125 Amp -4 Nos.
vi) Outgoing switch fuse unit/ fuse switch unit cat AC 23 (TPN)
with HRC fuses 63 Amp -5 Nos.
vii) Sleeved/ epoxy coated copper bus-bar - 800 A for phase and
400 A for neutral.
Supply, erection, testing and commissioning of 20 panel LT
switch board comprising of following :
i)incoming ACB 800A, 4 pole , 50kA (manual draw out type ) with
CTR 800/5A - 2 Nos
ii) ACB bus coupler 1600A, 4 pole, 50kA (fixed type) - 1 No
iii) On load change over switch 800A, 4 pole, Cat AC 23 - 1 No.
iv) Outgoing switch fuse unit/ fuse switch unit cat AC 23 (TPN)
with HRC fuses 400 Amp) -3 Nos.
33026 v) Outgoing switch fuse unit/ fuse switch unit cat AC 23 (TPN) No. 2,030,415 200,785 1 2030415 200785 2231200
with HRC fuses 250 Amp) -4 Nos
vi) Outgoing switch fuse unit/ fuse switch unit cat AC 23 (TPN)
with HRC fuses 125 Amp -4 Nos.
vii) Outgoing switch fuse unit/ fuse switch unit cat AC 23 (TPN)
with HRC fuses 63Amp -5 Nos.
viii) Sleeved/ epoxy coated copper bus-bar - 1600A for phase
and 800A for neutral.
Supply erection/ fixing of fire extinguishing equipments (ISI)
Marked, Rubber mat (ISI marked), G.I. fire buckets filled with
clean dry sand held on free standing steel stand, first aid box
with medicine (ISI marked) and associated materials, shock
33029 treatment chart on aluminium frame, schematic diagram of Set 77,944 12,241 1 77944 12241 90185
HT/LT installation & transformer data on white hylem sheet with
aluminium frame & fixing/ providing in the sub station area as per
details in Explanatory notes.
Supply, installation, testing and commissioning of DG set with
33030 acoustic enclosure, complete with AMF panel and all other
accessories and construction of plinth etc.
82.5 kVA DG set with 160amp, 4-pole, MCCB 50 kA
(i) (Ics=100%Icu) , 250amps copper bus-bars, 4 pole contactors Set 690,626 76,736 0 0 0 0
250 amp.

Page 27 of 38
160kVA DG set with 250amp, 4-pole,MCCB 50 kA
(ii) (Ics=100%Icu) , 400 amps copper bus-bars, 4 pole contactors Set 1,136,396 126,266 1 1136396 126266 1262662
400 amp.
250 kVA DG set with 400 amp, 4-pole,MCCB 50 kA
(iii) (Ics=100%Icu), 600 amps copper bus-bars, 4 pole contactors Set 1,704,245 189,360 0 0 0 0
600 amp.
500 kVA DG set with 800 amp, 4-pole ACB (MDO), 800 amps
(iv) Set 3,328,963 369,885 1 3328963 369885 3698848
copper bus-bars, 4 pole contactors 1000 amp.
Supply, erection, testing and commissioning of 125 kVAR
Automatic power Factor controller panel (capacitor bank)
33031 No. 622,727 61,579 4 2490908 246316 2737224
complete & connection with the main panel as per site
requirement.
SECTION - F : EARTHING ARRANGEMENT
33032 Earthing with 3 meter long, 50mm dia, G.I. pipe class 'B' earth Job
electrode, adding the charcoal or coke and salt, providing
concrete enclosure and MS cover plate with lifting arrangement
3,270 514 180 588600 92520 681120
etc. including connections with 4mm G.I. wire from earth
electrode to switch board / electrical equipment as required.

33033 Earthing with 600mmx600mmx6mm thick G.I earth plate, adding Job
of charcoal or coke and salt, providing concrete enclosure and
3,633 569 6 21798 3414 25212
MS cover plate with lifting arrangement, watering pipe etc. as
required.
33034 Earthing with 600mmx600mmx3mm thick copper earth plate, Job
adding of charcoal or coke and salt, providing concrete
6,417 1,007 6 38502 6042 44544
enclosure and MS cover plate with lifting arrangement, watering
pipe etc. as required.
EARTH CONNECTIONS
33035(i) Supply and laying 25mm x6mm G.I. strip at not less than 0.50 Meter
73 13 600 43800 7800 51600
meter below ground or in recess as required.
33035(ii) Supply and laying 40mm x 6mm G.I. strip at not less than 0.50 Meter
120 18 300 36000 5400 41400
meter below ground or in recess as required.
33035(iii) Supplying and fixing 40mm x 5mm copper strip on surface or in Meter
952 150 120 114240 18000 132240
recess or in 50mm dia G.I. pipe as required.
SECTION - G : CABLING

Supply, and laying of 1.1 KV grade LT XLPE insulated


armoured, aluminium conductor cable, making good the
33036 damages, end terminations with aluminium crimping socket/
plugs, provisions of cable route markers, testing &
commissioning etc. as required as per technical specifications.
i) 2 Core 16 sq.mm Meter 316 156 900 284400 140400 424800
ii) 2 Core 25 sq.mm Meter 366 156 1500 549000 234000 783000
iii) 2 Core 70 sq.mm Meter 625 156 18000 11250000 2808000 14058000
iv) 2 Core 185 sq.mm Meter 1,289 156 600 773400 93600 867000
v) 4 Core 16 sq.mm Meter 409 156 30000 12270000 4680000 16950000
vi) 4.0 Core 35 sq.mm Meter 577 156 24000 13848000 3744000 17592000

Page 28 of 38
vii) 4.0 Core 70 sq.mm Meter 921 156 6000 5526000 936000 6462000
viii) 4.0 Core 120 sq.mm Meter 1,454 156 600 872400 93600 966000
ix) 4.0 Core 185 sq.mm Meter 2,035 156 600 1221000 93600 1314600
x) 4.0 Core 300 sq.mm Meter 3,298 156 600 1978800 93600 2072400
xi) Single Core 400 sq.mm Meter 1,060 156 600 636000 93600 729600
SECTION - H : ELECTRIFICATION BY HIGH MASTS
Supply, erection, testing & commissioning of hot dipped
galvanised , high mast system complete with all accessories,
foundation, carriage arrangement suitable for LED luminaries
33037 symmetrically arranged & control gear boxes and lighting finial
etc., twin dome aviation obstruction lights, control panel, multi
core flexible copper conductor cable, connection to earthing
system and fencing panel as per requirement.
(i) 16 Meter high mast system, suitable for 6 to 9 nos luminaires. Job 281,916 44,450 3 845748 133350 979098
(ii) 12 Meter high mast system, suitable for 6 to 9 nos luminaires. Job 245,087 40,640 4 980348 162560 1142908
(iii) 25 Meter high mast system suitable for 9 to 12 nos luminaires Job 430,540 48,260 1 430540 48260 478800
section - I : LAYING OF 11 KV / 33 KV CABLES
Supply and laying of following sizes XLPE (E) insulated,
33038
armoured, aluminium conductor HT cable.
(i) 11 kV, 3 Core 70sq mm Meter 896 228 600 537600 136800 674400
(ii) 11 kV, 3 Core 185 sq mm Meter 1,590 228 1800 2862000 410400 3272400
(iii) 33 kV, 3 Core 300 sq mm Meter 2,219 228 600 1331400 136800 1468200
(iv) 33 kV, 3 Core 400 sq mm Meter 2,789 228 600 1673400 136800 1810200
Supply and erection of RFID based electronic Cable/pipe marker Nos
of reputed make suitable to work upto 1.5m depth, min dia of 22
CMs, having inbuilt GPS module for storing GPS coordinates,
each marker identification with 10 digits Hexadecimal Code,
33039 (i) 134.0 KHZ frequency with self generated power source having 2,100 50 3 6300 150 6450
capability to receive signals and transmit back, working life >= 40
yrs. Marker to be similar to Smart RFID marker SM 1500 or
superior as approved by Engineer.

33039 (ii) Supply and erection of MS cable route marker No. 384 18 60 23040 1080 24120

Supply of outdoor type, heat shrinkable, end termination kit,


33040 suitable for following cable sizes XLPE(E) insulated, armoured
aluminium conductor cable and making termination, connections
with overhead conductor, testing and commissioning etc.
(i) 3 core 11 kV 70 to 185 sq mm No. 12,809 2,012 6 76854 12072 88926
(ii) 3 core 33 kV 240 to 400 sq mm No. 40,174 3,973 6 241044 23838 264882

Page 29 of 38
Supply, Testing and commissioning of RFID Marker locator 1.5m
Depth Range, capable of acquiring and storing min 8000 RFID
marker records, having built in GPS Module for logging GPS
33041 coordinates and audio guidance for operator to navigate to Nos 313,000 3,400 1 313000 3400 316400
locations of RFID markers, LCD/LED Display, data port to allow
data output to PC with marker database software . Similar to
Smart RFID marker locator Energy/SML or superior as
approved by Engineer.
Supply erection of pre-stressed, cement concrete (PSCC)
double pole structure 9-11 meters long suitable for 330KG
working load with top section 200mm x 105mm and bottom
section 410 mm x 140 mm complete with 4 nos. channel cross
33042(i) No. 77390 7652 1 77390 7652 85042
arms & 2 nos cross bracing angles, clamps, bolt, nuts,
galvanized stay set, anti climbing devices, Danger plates on the
erected pole galvanised stay rod, casting of foundation for poles
& stay etc. as required.
Supply of Material fabrication and erection of 9-11 m long 'H'
pole (Double pole) with M.S Beam 150mm x 150mm, 4 nos.
channel cross arms & 2 nos cross bracing angles, clamps, bolts,
33042(ii) nuts, galvanized stay set, anti climbing device, Danger plates on No. 86717 21679 3 260151 65037 325188
the erected pole galvanised stay rod, casting of foundation for
poles & stay and painting etc. as per concerned SEB
requirements.
Supply and erection of 11 kV Porcelain Disc insulator complete
with galvanised iron hardware etc. including terminating with
33043 No. 1,395 138 12 16740 1656 18396
11kV / 33 kV overhead conductor and dismantling, handing over
works as required.
Supply and laying of HDPE pipe DWC/Split DWC type, of size
200 mm outer dia Grade PN4, PE80, ISI marked (either single
piece of full round or two half round split pieces set), under the
33044(a) Railway track/ road etc. digging of trench and back filling with Meter 348 22 60 20880 1320 22200
excavated earth after laying of pipe and making good the
damages as required.
Supply and laying of HDPE pipe DWC/Split DWC type, of size
200 mm outer dia,Grade PN4, PE80, ISI marked (either single
33044(b) piece or full round of two half round split pieces set), under the Meter 348 818 60 20880 49080 69960
Railway track/ road etc. with trench less method and making
good the damages as required.
Supply and laying of HDPE pipe DWC/Split DWC type, of size
63 mm outer dia, Grade PN4, PE80, ISI marked (either single
piece of full round or two half round split pieces set), under the
33044 (c) Meter 78 22 180 14040 3960 18000
Railway track/ road etc. digging of trench and back filling with
excavated earth after laying of pipe and making good the
damages as required.

Page 30 of 38
Supply and laying of HDPE pipe DWC/Split DWC type, of size
63 mm outer dia, Grade PN4, PE80, ISI marked (either single
33044 (d) piece or full round of two half round split pieces set), under the Meter 78 818 180 14040 147240 161280
Railway track/ road etc. with trench less method and making
good the damages as required.
Supply and laying of HDPE pipe DWC/Split DWC type, of size
110 mm outer dia, Grade PN4, PE80, ISI marked (either single
piece of full round or two half round split pieces set), under the
33044 (e) 314 22 300 94200 6600 100800
Railway track/ road etc. digging of trench and back filling with
excavated earth after laying of pipe and making good the
damages as required.
Supply and laying of HDPE pipe DWC/Split DWC type, of size
110 mm outer dia, Grade PN4, PE80, ISI marked (either single
33044(f) piece or full round of two half round split pieces set), under the 314 818 300 94200 245400 339600
Railway track/ road etc. with trench less method and making
good the damages as required.
Supply and laying of HDPE pipe DWC/Split DWC type, of size
160 mm outer dia, Grade PN4, PE80, ISI marked (either single
piece of full round or two half round split pieces set), under the
33044(g) 655 22 300 196500 6600 203100
Railway track/ road etc. digging of trench and back filling with
excavated earth after laying of pipe and making good the
damages as required.
Supply and laying of HDPE pipe DWC/Split DWC type, of size
160 mm outer dia Grade PN4, PE80, ISI marked (either single
33044(h) piece or full round of two half round split pieces set), under the 655 818 300 196500 245400 441900
Railway track/ road etc. with trench less method and making
good the damages as required.
33044 (i) Extra on 33044(a), (c), (e), (g) for hard soil/soft rock locations. Meter 11 60 0 660 660
33044 (j) Extra on 33044(b), (d), (f), (h) for hard soil/soft rock locations. Meter 409 60 0 24540 24540
SECTION - J : PROVISION OF PUMPS

Supply, installation, testing and commissioning of submersible


pump set suitable to operate on 3 phase, 415V, 50 Hz AC supply
along with control panel etc. complete for supplying water at
33045 suitable discharge and head as per site requirement.
(i) 7.5 HP pump set Job 90,811 8,979 1 90811 8979 99790
(ii) 5 HP pump set Job 83,163 8,225 3 249489 24675 274164
SECTION - K : MISC. WORK

Page 31 of 38
Co- ordination/ liasoning and chasing with State Utility Company
for availing new electrical connection/ augmentation of
sanctioned load at stations, level crossings etc. including
applying for load, collection of estimates for loads, modification Each
33046 of power line crossings, arranging payment from RVNL, Location 0 9,690 9 0 87210 87210
depositing payment to State Utility Company, arranging release
of load & other related works, payment to be made to SEB for
new connection, load augmentation, modification of power line
crossings etc. shall be made by RVNL.

Design and preparation of working & completion drawings of all


HT/LT electrical installations of the project section where work is
carried out such as platform lighting, internal electrification of
33047 staff quarters, level crossings, station building, offices, power Job 0 199,710 3 0 599130 599130
line crossings, power supply distribution arrangements of
stations / sub-stations, electrification of sub-station buildings etc
& approval from the competent authority.
Conducting check survey of the complete project section to
compile details of all the existing LT, HT, and EHT Power line
Electrical overhead and underground power/telegraphic/other
lines running along or across the track and recording
measurements of horizontal distances of structures from the
existing & proposed tracks, vertical clearance of conductors &
guard wire from rail level, angle of crossings w.r.t. track, height
and type of towers/poles and preparation of lists as below:
33048 i) List of Overhead/Underground Crossings infringing and Job 0 157,665 1 0 157665 157665
requiring modification. Proposed modification may also be
indicated.
ii) List of Overhead/Underground Parallel Alignments infringing
and requiring modification.Proposed modification may also be
indicated.
iii) List of overhead/underground crossings/parallel Alignments in
conformity with the Rules/regulations and not requiring
modification.

Supply, installation, testing & commissioning of outdoor type,


single side /Double side Glow sign boards/Pictorial signage
boards with suspension/side mounting/wall mounting type
33049 Sq. Feet 405 61 1800 729000 109800 838800
arrangements as required. (Payment for Double sided glow sign
board shall be made @ 150% of the rate of single sided glow
sign boards)

Page 32 of 38
Supply, installation, testing & commissioning of Silicon rectifier
battery charging set conforming to relevant IS (latest), suitable
33050 for operation on 3 phase 4 wire, 415 Volts AC supply system, No. 135,782 21,326 2 271564 42652 314216
125 Volts to 150 Volts DC output, 200 Amps capacity as per
Tech Specification including earthing, etc as required.
Fabrication, supply, installation, testing and commissioning of
110 Volts battery charging point suitable for operation on 150
33051 Job 4,910 772 18 88380 13896 102276
Volts DC supply system including erection on MS channel,
foundation etc complete.
Fabrication, supply, installation, testing and commissioning of
33052 Job 13,287 2,087 18 239166 37566 276732
pre-cooling point as per details given in explanatory notes.
SECTION - N : DISMANTLING WORKS
Dismantling of wiring installations of buildings, sheds, quarters,
etc. complete with luminaries, fans, distribution boards, LT
Each
Panels and associated cables including accountal, stocking,
33053 Station/G 0 9,189 18 0 165402 165402
transportation and handing over of released materials to
ate lodge
Electrical department as directed by the Engineer and making
temporary arrangements if required.
Dismantling of erected pole/overhead conductor, GI wire, cross
arm brackets, insulators, stay, luminary etc including accountal,
33054 (i) stocking, and handing over the released materials to railway's No. 0 919 18 0 16542 16542
authorized official as instructed by the Engineer and making
temporary arrangements if required.
Dismantling of sub-station equipments such as transformers,
DG Set, HT & LT Panels, cables etc at site including
33054 (ii) transporting, stocking and handing over to Electrical department Job 0 18,377 1 0 18377 18377
as instructed by the Engineer and making temporary
arrangements if required.
Provision of temporary lighting arrangement with 1x40 watt F.L
tube light/CFL/LED/Halogen/MH/flood light fitting and
pedestal/ceiling fans, desert coolers in temporary tents,
buildings, goomties, on tracks, in yard area including wiring,
cabling, earthing etc as directed by the Engineer and as per site
33055 (i) requirement for pre/post/during non-interlocking period, including Per day 0 27,565 90 0 2480850 2480850
providing stand by D.G set of suitable capacity and deployment
of staff for operation of DG set as per site requirement.
NOTE: Normal power supply may be used, up to sanctioned
load, if surplus available at site.

Extra for operation and maintenance of temporary wiring


33055 (ii) installations, replacement of consumables, supply of diesel oil, Per day 0 5,470 9 0 49230 49230
lub oil etc for operation of DG set etc.

Page 33 of 38
Supply, installation, testing and commissioning of AC unit,
complete with LCD display cordless remote, min 3 star energy
33056 rating, suitable for 1-Phase, 230 volts +-10% AC supply 0 0 0
including supply & installation of suitable rating, wall mounted, IC
controlled electronic auto voltage corrector.
(a) 2.0 Tonne window type AC No. 48,538 3,675 6 291228 22050 313278
(b) 1.5 Tonne window type AC(minimum 5-star rating) No. 37,596 3,675 6 225576 22050 247626
(c) 2.0 Tonne split type AC, inverter type(minimum 3-star rating) No. 65,582 3,675 6 393492 22050 415542
(d) 1.5 Tonne split type AC, inverter type No. 46,789 3,675 6 280734 22050 302784
Supply & erection of G.I Octagonal pole including digging of pit,
making foundation with cement, sand & concrete in ratio 1:2:6,
33057
muffing, accommodating G.I pipe in foundation for cable loop-in-
loop out of suitable size as required
i) 5 meters long No. 11,830 2,904 600 7098000 1742400 8840400
ii) 7 meters long No. 16,399 4,026 120 1967880 483120 2451000
Additional cost of single arm bracket suitable for street light
iii) 493 122 600 295800 73200 369000
fixture No.
Additional cost of double arm bracket suitable for street light
iv) 585 145 120 70200 17400 87600
fixture No.
Supply installation testing & commissioning of cubical type mast
33058 mounted, dust & vermin proof, LT control switch board 0 0 0
conforming to IS:8623 (latest version), complete.

i) a) with TPN MCCB 32A, 35 KA, fixed type ( Ics=100% Icu)-1 No 14,960 3,672 60 897600 220320 1117920
b) copper busbars 200A ( for 5 KVA AT) No.

ii) a) with TPN MCCB 63A, 35 KA, fixed type ( Ics=100% Icu)-1 No 17,521 4,300 18 315378 77400 392778
b) copper busbars 200A ( for 10 KVA AT) No.
a) with TPN MCCB 150A, 35 KA, fixed type ( Ics=100% Icu)-1
iii) No 20,817 5,108 2 41634 10216 51850
b) copper busbars 300A ( for 25 KVA AT) No.
Section - P (Misc. Items)
Supply installation testing & commissioning of 15W LED Solar
Street light system with 6/7 m pole GI complete with all
33059 54,907 3,940 18 988326 70920 1059246
accessories as per RDSO specifications RDSO/PE
/SPEC/PS/0093-2008 (Rev.0) Amend-3 or latest. No.
Supply erection testing & commissioning of FLAT PLATE
COLLECTOR BASED type solar water heating system of 300
liters capacity complete with solar collector, insulated tank,
33060 supporting stand, connecting pipes, instrumentation etc including 55,821 13,956 2 111642 27912 139554
tapping of water supply from the existing arrangement/system as
required. Job
Design, supply, erection, and commissioning of grid connected
solar power plant consisting of solar panels, PCU mounting
33061 KWp 60,000 6,125 96 5760000 588000 6348000
structures and all other associated equipments as per
RDSO/PE/SPEC/PS/0092-2008 (Rev.0) with latest amendment.

Page 34 of 38
Supply & erection of perforated cable tray size 75 x 75x350 mm,
33062 manufactured with 2 mm thick G.I Sheet holding on G.I angle Meter 706 177 78 55068 13806 68874
50x50x6 mm for supprot as required.
Supply and installation of Furniture set for substation control
33063 (i) Set 81,442 0 0 0 0 0
room.
33063 (ii) Supply and installation of Ladder set. Set 139,359 0 1 139359 0 139359
Supply and erection of all types of galvanised Steel
33064 StructuresSmall Parts Steel etc for the exclusive work in the field MT 103,710 3,485 0 0 0 0
of General Electrical Service.
Supply, erection, testing and commissioning of 33 KV, 1560
MVA 3 pole type, VCB panel out door type, breaking capacity
33065 1560A , with terminal connector suitable for DOG ACSR Nos 855,509.00 95,056.00 0 0 0 0
conductor, spring operated motor mechanism , with all standard
essential accessories and post /support insulators as required .
Supply erection testing and commissioning of control & relay
panel for 33 KV VCB (triple pole) and 33/11KV 3000 KVA
transformers with necessary numerical relays and indicating
33066 Nos 285,169.00 31,685.00 0 0 0 0
devices including measurement of energy and MD. This shall
include outdoor CT & PT with post insulators etc including
control cables as required for above functions.
Supply erection testing and commissioning of 33 KV/42 KV peak
33067 non linear resistor type station class Lightening arrestor, with Set 57,033.00 6,337.00 0 0 0 0
surge monitor complete with all accessories.
Supply erection testing and commissioning of 33 KV, 400 A
outdoor type triple pole horizontal mounting rotating type double
33068 Set 33269 3697 0 0 0 0
air break gang operated Isolator with all standard accessories
and post insulators as required.
Supply erection testing and commissioning of 33 KV Bus bar
made of ACSR DOG conductor of size 16/4.72+7/1.57 mm
33069 Mtr 66 8 0 0 0 0
including Disc type , post type insulators, jumper connection
with suitable connector ,clamps etc as required.
Supply erection testing and commissioning of 33 KV/11KV 3-
phase 3000 KVA ONAN outdoor type transformer with off load
33070 Nos 5,755,884 28,026 0 0 0 0
tap changer(+5% to -10% with 2.5% step size) with bushing
termination on 33 KV and cable box termination on 11 KV side.
Supply erection testing and commissioning of LED signage
33071 Sqft 5749 120 689880 0 689880
(similar to neon sign) M/s Glowz or similar
Supply erection testing and commissioning of LED edge lit
33072 Sqft 1695 60 101700 0 101700
signage board.
Supply and erection of stay set with CC foundation in ratio
33073 1:3:6, stay rod , stay tightner, stay insulator , GI wire 7/8 SWG, set 1835 0 0 0 0
thimble and other fixing accessories as required .

Page 35 of 38
Supply, erection and commissioning of hydraulic elevating
platform (articulated type-02 boom ) having working height of
9.5 mtr, outer reach of 3.7 mtrs, safe working load of 120kg ,
33074 slewing range of 300 degree, fibreglass cage of required size to Nos 1,100,900 1 1100900 0 1100900
facilitate fixing of fittings and maintenance of electric poles
suitably mounted on TATA ACE, HT BS–IV chassis and engine
complete with all accessories.
Supply and installation of Refrigerator minimum 270 Ltr capacity,
33075 double door, min 3 star rating suitable for 230 V AC supply with Nos 18,161 1 18161 0 18161
stabilizer of suitable rating.
Total ( Schedule 33000) 113,238,111.00 31,459,179.00 144,697,290.00
Non Schedule Items
Providing Road Vehicle mentioned below for the use of
Engineer/Employer as per the Conditions mentioned in Clause 3.4.3, i.e
NS-1
3.4.3.1 to 3.4.3.3 of Chapter 3 (Site Facilities for the Employer and the
Engineer) of Section 5 Work's Requirement) of Tender Documents.
(a) Tavera, Innova or similar nos. 53199 22 1170378 1170378
(b) Tata Sumo, Bolero or similar nos. 45776 120 5493120 5493120
Extra for running and maintenance of every additional km over and
(c) Per Km 12.38 3600 44568 44568
above 4000 kms as specified in item NS-1(a)
Extra for running and maintenance of every additional km over and
(d) Per Km 9.9 6000 59400 59400
above 4000 kms as specified in item NS-1(b)
Total ( Schedule 33000)NS 10,877,436.00 6,767,466.00
Grand Total 151,464,756.00

Page 36 of 38
ELECTRICAL GENERAL SERVICES/EXPLANATORY NOTES
Schedule-33000(GENERAL ELECTRICAL WORKS)
(Quarters, Service buildings, Pumps, Track crossings etc.)

1. Explanatory notes for various items of work in Electrical General Services Schedule are given
below:

i All electrical works should comply with Indian Electricity Act 2003 and Rules framed there under.

ii All electrical installations shall conform to the relevant Indian Standard and shall be carried out
as per the relevant safety Code of Practices and guidance for Safety Procedures in Electrical
Works as per IS:5216/Pt I & II/1982.

iii Notwithstanding the ratings specified in the BOQ, all components proposed to be used in the
installations, shall be of appropriate rating of voltage, current and frequency without any
additional financial implication on RVNL. Discrepancies, if any, in this regard, shall be brought
to the notice of the Engineer by the Contractor.

iv All minor items viz. hardware items, foundation bolts, termination lugs for electrical connections
etc. as required and necessary for proper working of the equipment shall be deemed to have
been included in the Bill of Quantities, whether such items are specifically mentioned or not.

v (a) The basic quantities of components & materials required to make up a unit of work for selected
items are approximate. The Contractor shall plan the work, estimate the actual quantities
required and get the same approved by the Engineer before placing orders.

(b) In estimating the prices for various items of work, provision for loss or wastage in transit and
erection including freight, handling, taxes and duties, insurance if any etc. should be taken into
account and firm unit price offered for a complete unit of work to be done by the contractor.
vi The various items to be supplied/provided/erected should be as per the list of approved
suppliers included in RVNL’s Technical Specifications/list followed by concerned zonal Railway.
Items not appearing in the approved list shall be procured from good quality sources in line with
best industries practices and shall be either ISI marked or conforming to latest IS (if any). Before
procurement, vendor approval shall be obtained from the Employer.
vii Good workmanship and total compliance with safety and other statutory rules and regulations,
shall invariably be observed by the Contractor.
viii All approvals from the relevant and appropriate government & statutory authorities shall be the
total responsibility of the Contractor unless specified otherwise.

ix All quoted rates shall cover supply of materials, handling of materials, labour required, civil
works, taxes and duties, fabrication, installation, testing and commissioning, training and free
maintenance till handing over to the Employer’s representative.
x If any activity of work is essential for the satisfactory completion of the work but is not mentioned
specifically in the Bill of Quantities or elsewhere in the bidding documents, the same shall be
deemed to be included In the scope of work and shall be executed by the contractor within the
accepted cost. The work shall be handed over in a functional manner complete in all respects.

xi The inspection of various items shall be carried out by the agencies as specified in RVNL
specifications. The prices quoted also include RITES/RDSO representative inspection and
testing charges unless otherwise specified in the bill of quantities or Technical Specification. In

IFB No: RVNL/BSB/GEW/PEP-IAA,MAU-SHG/11

1
03/06/2018
ELECTRICAL GENERAL SERVICES/EXPLANATORY NOTES
case of change of inspection from RDSO/RITES to RVNL/CONSIGNEE, 1% of the cost of
material will be deducted by RVNL as inspection charges.

xii The inspection of above items will be done at the manufacture’s works/place decided by the
Employer based on item, its quantity, Inspecting Authority etc.

2. DRAWINGS
2.1 The contractor shall prepare drawings in Auto Cad for all LT/HT installations, indicating proposed
works and shall obtain approval of Engineer prior to taking up the work. Such drawings shall be
prepared in coordination with all other agencies executing works at the same site and a maximum of
10(ten) copies as are required by RVNL with one tracing on RTF paper.
2.2 After commissioning, these drawings shall be duly updated as per erection work at site and submitted
in six copies and one tracing in RTF paper, as Completion Drawings, along with a soft copy to the
Employer.
2.3 Where the contractor proposes to use an item of equipment, other than that specified or detailed on
the drawings, which requires any re-design of the structure, partitions, foundation, piping, wiring or
any other part of the mechanical, electrical or architectural layouts, he shall inform the Engineer well
in advance and obtain his approval. Delays resulting from such re-design shall be On Contractor’s
account. He shall also submit all related information as may be required for approval of such redesign,
to the Engineer.

2.4 Where the work of the Contractor has to be executed in close proximity to or will interfere with work
of other agencies, the Contractor shall work out space/time adjustments in coordination with other
agencies. If the contractor installs his work before coordinating with other agencies, so as to cause
any interference with their work, he shall make the necessary changes without extra cost to the owners
of the installation.

3. EXPLANATORY NOTES FOR BOQ ITEMS

The descriptions of all items are self explanatory. These Explanatory Notes are supplementary to the
BOQ description. Further details are available in latest booklet of RVNL’s STANDARD
SPECIFICATIONS FOR MATERIAL AND WORKS Volume-II(GENERAL ELECTRIFICATION AND
RAILWAY ELECTRIFICATION WORKS) as amended from time to time.

NOTE: Following particular requirements shall be followed for wiring works:

1 No conduit shall be of size less than 20 mm.

2 Occupancy of wiring cable in conduit shall not exceed 45% of the capacity of conduit.

3 Switch boxes shall be of galvanized sheet metal of suitable sizes from approved sources:

4. Separate conduit shall be laid for each circuit/sub main/main wiring.

5 Water cooler/AC Points and other such inductive loads shall be controlled with “C” series
MCBs.

6 Neutral cable shall be brought into each switch box.


IFB No: RVNL/BSB/GEW/PEP-IAA,MAU-SHG/11

2
03/06/2018
ELECTRICAL GENERAL SERVICES/EXPLANATORY NOTES

7 Earth cable shall be brought into each switch box.

8 Fan point wiring shall include supply & fixing of fan box.

9 Approx.150 mm long wiring cable shall be kept loose in switch box/SDB/DB etc.
10 Conduits laid in sheds shall be clamped with the shed structure with clamps made from
GI. strips of 25x1.6mm and spaced at about 1000mm interval, fixed with 8mm dia bolts
with nuts.

11 Brass screw and cup washers shall be used for fixing sheets on the front of switch box .

12 All the wiring work shall be in conformity with IS732/1989 (Latest Version) CODE OF
PRACTICE FOR ELECTRICAL WIRING INSTALLATIONS & IS 4648/1968 (Latest
Version) Guide for Electrical Wiring in Residential Buildings.

13 The equipments which are available with ISI mark in Indian market, they shall be supplied
having ISI mark only whether specifically mentioned in BOQ & its explanatory notes or
not.
14 All the energy consuming equipments which are available in Indian market with energy
star rating issued by BEE, shall be supplied with minimum 3 star energy rating only
whether specifically mentioned in BOQ & its explanatory notes or not.

33001 (ii) to (vi) ELECTRIFICATION OF STAFF QUARTERS

Deleted

33002: ELECTRIFICATION OF GATE MAN LODGE AT LEVEL CROSSING


(a) The item price includes cost of labour & all materials required to electrify the gate man lodge in all respect
complete with ceiling fans, luminary with lamps and other items indicated in scale of fittings including cost of
wiring cables (sizes indicated for point wiring, circuit wiring), PVC conduits with accessories, junction boxes,
modular switches, metal boxes, lamp holders and ceiling roses, modular plate, pre wired sub distribution board,
earth electrodes etc.
(b) Scale of fittings, wiring points, fans, luminary etc. and Cable sizes, no. of wires permissible in each circuit and
sub main, etc has been indicated below.
(c) Payment for providing bracket on wall is included under item for GI pipe and shall be made on measurement
of length basis.

IFB No: RVNL/BSB/GEW/PEP-IAA,MAU-SHG/11

3
03/06/2018
ELECTRICAL GENERAL SERVICES/EXPLANATORY NOTES
SCALE OF ELECTRICAL FITTINGS

Details of LP TLP F P STL PP5A Total Points DB EE


Points (T-5)

Quantity 2 2 1No. 1No. 1No. 7 Nos. 1No. 1No.


No. No.

Abbreviations

LP Light point with 11W LED STL light point with 23-27 watt street light (aluminium sheet)
lamp as approved by LED fitting with lamp and G.I.pipe bracket grouted on
engineer wall

FP Ceiling Fan point with 1200 D B Pre wired Distribution board comprising of following:-
mm fan & with suitable
rating for the C/Fan, stepped ∑ Incoming DP MCB32A with 100mA RCCB ---
1No.
type Electronic regulator
∑ Outgoing SP MCB 6-16A – 4Nos.
∑ 100A copper bus bars
TLP light point with 18-22 W
T-5 LED tubelight as approved
by engineer EE G.I.pipe earth electrode
PP5A Light plug point complete
with socket and switch

Sizes of single core (copper conductor) cable for point wiring, circuit wiring,

Size of
circuit
Size of point wiring cable Nos. of circuits
wiring
cable

LP LED FP STL PP5A LP &FP PP5A STL

Phases
and 1.5 sq.mm 2.5 sq.mm 1 No. 1 No. 1 No.
neutral

IFB No: RVNL/BSB/GEW/PEP-IAA,MAU-SHG/11

4
03/06/2018
ELECTRICAL GENERAL SERVICES/EXPLANATORY NOTES
Continu
ous
earth 1.5 sq.mm 2.5 sq.mm

33003 (i) to (iv)


ELECTRIFICATION OF SERVICE BUILDINGS, PASSENGER SHELTER, SHEDS, PUMP HOUSE,
SUB STATION BUILDINGS, OFFICES ETC
a) The item price includes cost of labour & all materials required to electrify the buildings in all respects in
surface/recess (excluding supply and erection of fans, luminaries, air conditioners, water coolers, geyser
which are covered elsewhere under BOQ). The cost includes wiring cables (sizes indicated for point wiring,
circuit wiring and sub main wirings), PVC conduits with accessories, junction boxes, modular switches,
metal boxes, lamp holders and ceiling roses, modular plates sub distribution boards, distribution boards and
earth electrodes etc.

b) Service buildings shall also include buildings at isolated locations such as relay huts at level crossings etc.
c) Wiring for essential and non essential load and their control shall be carried out separately at station
buildings and other locations as required.

d) The payment for provision of industrial type iron clad plug socket with 32A DP MCB in M.S.Box [Item
33003(iii)] shall be paid in addition to one power point work covered under 33003(ii).

NOTES: -

i) Earth Electrode shall be provided for each building as per IE rules.

ii) Single phase distribution system is permitted up to 10 KW load calculated on the basis of load of
points as indicated here under.

iii) Three phase distribution system shall be carried out for the buildings having load above 10 KW
calculated on the basis of load of points as indicated here under.

iv) Separate SDB’s shall be provided for L&F and Power loads as per site requirements.

v) Each SDB shall be provided with RCCB 100 mA with incoming DP MCB.

vi) Each Distribution Board and Sub Distribution board shall be designed based on the requirement of
load as per site conditions and considering 25% additional circuits (minimum- 1 No.) as spare (MCB)
on outgoing and minimum 50% additional load on Incoming (for future requirements)

vii) Approval for design shall be obtained from the Engineer, prior to ordering boards on the basis of
sample calculation for assessment of electrical load, circuits and wattage of points as indicated below.

IFB No: RVNL/BSB/GEW/PEP-IAA,MAU-SHG/11

5
03/06/2018
ELECTRICAL GENERAL SERVICES/EXPLANATORY NOTES

(A-1) Sample Calculation for Assessment of Electrical load, Circuits and wattage of points

Light Point Ceiling Fan Exh. Fan Point Light Plug point Power plug point Geyser PP 32A
/Call Bell point Point 5A 15A Point Air
Conditioner
Point /Water
Cooler
60 Watts. 100 Watts 200 watts 100 Watts 500 Watts 1500 2000 Watts
Watts

A-2) Sample Calculation for Assessment of Electrical load and Circuits:-


Building with load as detailed here under
LIGHT & FAN CIRCUIT POWER CIRCUIT

Light Ceiling Exh. Fan Light Plug Power Geyser PP 32A Air Conditioner
Point Fan Point Point point plug point Point Point /Water Cooler
/Call 5A 15A
Bell
point

Wattage of 60 Watts. 100 Watts 200 watts 100 Watts 500 Watts 1500 Watts 2000 Watts
points
No. of points 25 10 4 5 4 1 2
Total watts 1500 1000 800 500 2000 1500 4000
Total Load 3800 watts 7500 watts
No. of 8 Nos 3 Nos 1 Nos 1 Nos 1 Nos
points
permitted in
a circuit
No. of 5 Circuits 2 Circuits 4 Circuits 1 Circuits 2 Circuits
circuits
Total circuits 7 Circuits 7 Circuits
Sub Incoming 40 A DP MCB with RCCB --- 1 No Incoming 63 A DP MCB with RCCB—1 No,
Distribution Outgoing SP MCB 6--16amps—9 Nos. Outgoing (including spares)
Board (including spares) (i) SP MCB 32A -- 3 Nos. for (AC/WC)
(ii) SP MCB 20A – 2 Nos. For Geyser
(iii) SP MCB 16A – 5 Nos. for 15A plugs
Distribution Incoming 63 A TPN MCB --- 1 No
Board Outgoing (including spares)
DP MCB 63 amps --2 Nos
DP MCB 40 amps -- 2 Nos

IFB No: RVNL/BSB/GEW/PEP-IAA,MAU-SHG/11

6
03/06/2018
ELECTRICAL GENERAL SERVICES/EXPLANATORY NOTES
Nos. of points and size of wiring cables Minimum size (in Sq.mm)
of cable for
Size of circuit wiring cables Sub main
Size of point wiring cables(in Sq.mm) main wiring
for(in Sq.mm) wiring
G.I.Pipe
Light Earth
Group L&F
Point/Fan PP32A Ge Electrode
point PP and 15A. 32A. (AC/
Point/Call Bell GP (ACP/ ys 10 16
wiring/5A 15A 5A Plug WC etc)
point/ PP5A WC) er
wiring Plug
etc.

Pha
se/ (i) O
s ne No. for
4 6 6 4 4
1.5 2.5 2.5 6 10 16 Each
and single –
neu Phase
tral SDB/DB
co (ii) two
Nos. for
nti
each three
nu phase
1.5 2.5 4 6 6 2.5 4 4 6 10 16
ous SDB/DB
eart
h
Nos. of points No. of circuits permitted Minimum size (in
permitted in a circuit (In Nos.) in a Distribution Board Sq.mm) of cable for
Light Point/ PP
Fan Point/Call N4
PP5 PP32A For L&F and 5A For For 32A
Bell point/ 5 GP For Geyser
A (ACP/WC) plug 15A plug (AC/WC etc)
PP5A N4
etc. 5
4
8 1 1 1 12 12 Nos. 10 16
Nos.
A-3) Size/s of single core (copper conductor) cable for point wiring, circuit wiring and sub main wiring,
circuits, Sub Distribution Board/s for buildings offices etc.

Abbreviations

LP Light point PP5A Light plug point complete with socket and switch
FP Ceiling Fan point. PP15A Power plug point complete with socket and switch
CBP Call bell point PP32A (ACP/WC) Air Conditioner/Water cooler point with Industrial type iron
clad plug 32 amps & 20A DP MCB in metal clad box
EFP Exhaust fan point GP Geyser point
33004:Supply of light meter.

The item price includes cost of supply of light meter for measuring upto 200000 lux with battery and carry case
(HTC instrument make reference LX-103 or equivalent as approved by engineer.

IFB No: RVNL/BSB/GEW/PEP-IAA,MAU-SHG/11

7
03/06/2018
ELECTRICAL GENERAL SERVICES/EXPLANATORY NOTES
33008:Supply, installation, testing and commissioning of A.C. ceiling fan 1400mm (Without Regulator)
The item price includes supply & erection cost of all materials including cost of 230V A.C. 1400 mm ceiling fan
having 3/4 blades, double ball bearing, copper wound motor, suitably sized down rod, canopies and capacitor etc
complete with all accessories including fixing phenolic laminated sheet cover on the fan box, FR PVC insulated
multistranded single/three core copper conductor cable wiring and connecting with earthing system etc. Fan should
have ISI mark and as per IS-374/1979, min 3 star energy rating issued by BEE.
Fan point wiring is covered under item 33003.

33008A: Supply and erection of BLDC fan of 1200 MM sweep with remote

Supply Energy Efficient BEE 5 star rating brushless DC motor (BLDC) fan of size 1200 mm sweep with double
ball bearing, 300 mm down rod, canopies, shackles, 3 Nos. of blades, suitable for operation on 230V AC 50Hz,
Single phase supply, of the following specification
(i) The fan blade thickness should be minimum 1.1. mm
(ii) The fan should confirming to IS 374/1979 (latest)
(iii) The minimum Air delivery should be 220 m3/min
(iv) The fan should confirm to IS 616/2010 for safety requirement of Electronic equipment
(v) The speed control should be of remote controller.

The price shall also cover assembling of ceiling fan complete besides fixing to the hook and undertaking connection
from ceiling rose.
The price covers fixing phenolic laminated sheet cover on the fan box, FR PVC insulated multistranded single/three
core copper conductor cable wiring and connecting with earthing system, etc.
Fan point wiring is covered under item 33033.

33009: Supply, installation, testing and commissioning of stepped type, electronic fan regulator on the
existing phenolic laminated sheet.

The item price includes labour & cost of all materials including cost of stepped type, electronic regulator with
suitable rating for the C/Fan and connecting cables etc.

33010A: Supplying, installation, testing and commissioning of 11-15 W LED lamp as approved by Engineer.
The item price includes labour & cost of all materials including cost of FR PVC insulated multistranded single core
copper conductor cable, earthing etc. Luminary shall be provided on the bracket of pole / on wall / as required. For
provision of luminary on wall, G.I.Pipe bracket is payable under G.I.Pipe item (SBOQ 33019) on measurement of
length basis. It also includes in cost of 11-15 W LED lamp of approved make etc as approved by Engineer.

33010B: Supply, erection, testing and commissioning of Recessed type LED luminaries for 2x2 Grid ceiling, wattage 35-
40W suitable to work on 220-240V AC supply.
The item includes cost of 2'x2' grid type ceiling recessed LED type light fitting35-45 watt suitable to work on
220-240V AC supply. The item including cost of lamp of required wattage complete with all accessories of
approved make etc as approved by Engineer. The item price also includes labour & cost of all materials including
cost of FR PVC insulated multistranded single core copper conductor cable, earthing connection etc.

IFB No: RVNL/BSB/GEW/PEP-IAA,MAU-SHG/11

8
03/06/2018
ELECTRICAL GENERAL SERVICES/EXPLANATORY NOTES
33010 C :LED down lighter 14-16 watt.
The item price includes supply, erection, testing and commissioning of cost of LED down lighter fitting 14-16
watt complete with all accessories of approved make etc or as approved by Engineer. The item price also includes
labour & cost of all materials including cost of FR PVC insulated multistranded single core copper conductor cable,
earthing connection etc. The price also covers Suplly and erection of suitable clamps/brackets etc to fix light fittings
under COP/FOB/Poles/roofs/walls/ sheds etc.

33010D (i) to (iv)LED street light fittings


The item includes cost of LED street light fitting, pre die cast aluminium, IP-65, with high power LED lamp of
required wattage complete with all accessories of approved make etc as approved by Engineer. The item price also
includes labour & cost of all materials including cost of FR PVC insulated multistranded single core copper
conductor cable, earthing connection etc. The price also covers Suplly and erection of suitable clamps/brackets etc
to fix light fittings under COP/FOB/Poles/roofs/walls/ sheds etc.

33010E:Surface/wall mounted LED batten type light fitting 18-22 watt


The item includes cost of LED surface/wall mounted light fitting with power LED lamp of required wattage
complete with all accessories of approved make etc as approved by Engineer. The item price also includes labour
& cost of all materials including cost of FR PVC insulated multistranded single core copper conductor cable,
earthing connection etc. The price also covers Suplly and erection of suitable clamps/brackets etc to fix light fittings
under COP/FOB/Poles/roofs/walls/ sheds etc.

33010F: Seven(07) watt sleek LED mirror light fitting


The item includes cost of LED 7 watts sleek LED mirror light with diffuser and LED lamp similar to Crompton
Greeves Ltd Model LINNET LCL-07-CDL complete or equivalent as approved by Engineer. with power LED lamp
of required wattage complete with all accessories etc as approved by Engineer. The item price also includes labour
& cost of all materials including cost of FR PVC insulated multistranded single core copper conductor cable,
earthing connection etc. The price also covers Suplly and erection of suitable clamps/brackets etc to fix light fittings
under COP/FOB/Poles/roofs/walls/ sheds etc.

33010 G to I: LED flood light fitting


The item includes cost of LED flood light fitting, pre die cast aluminium, IP-65, with high power LED lamp of
required wattage complete with all accessories of approved make etc as approved by Engineer. The item price also
includes labour & cost of all materials including cost of FR PVC insulated multistranded single core copper
conductor cable, earthing connection etc. Price covers flood light fittings required for shetds, high masts, sports
facilities etc. The price also covers Suplly and erection of suitable clamps/brackets etc to fix light fittings under
COP/FOB/Poles/roofs/walls/ sheds etc.

33011 (a)(i), (ii),& (iii): Supplying, installation, testing and commissioning of Exhaust fan 300mm. 150mm,
450mm sweep
The item price includes labour & cost of all materials including cost of Exhaust fan (ISI marked, as per IS-2312),
min 3 star energy rating issued by BEE(if available in Indian market), grouting bolts & nuts, FR PVC insulated
multistranded single core copper conductor cable, connection to earthing system and making opening in the
wall/modifications as required, fixing of suitable plywood framing etc as approved by engineer. The exhaust fan

IFB No: RVNL/BSB/GEW/PEP-IAA,MAU-SHG/11

9
03/06/2018
ELECTRICAL GENERAL SERVICES/EXPLANATORY NOTES
should be preferably with louvers if available in Indian market. The price also covers supply and erection of suitable
clamps/brackets for fixing above.

33011(b): Supply, installation, testing and commissioning of Air circulating fan

The item price includes labour & cost of all material including Supply, installation, connection of single phase
230V, 50Hz air circulating fans of 700-750 mm sweep heavy duty, wall mounted including all accessories with
regulators similar to CGL model no. AC750WALL-1. Erection cost shall include cost of GI clamps and fixtures as
required for wall/structure mounting of fan and GI fasteners. as approved by engineer. The price also covers supply
and erection of suitable clamps/brackets for fixing above.

33011(c): Supply, installation, testing and commissioning of Air Curtains 1000mm


The item price includes labour & cost of all material including Supply, installation, connection of single phase
230V, 50Hz, 1000 mm high velocity air curtains conforming to CG model no.
CGHV1M.(Make:CG/Havell's/Polar), wiring and connecting with earthing system etc as approved by engineer.
The price also covers supply and erection of suitable clamps/brackets for fixing above.

33011 (d):Supply, installation, testing and commissioning of AC bracket fan 400 mm


The item price includes labour & cost of all materials including cost of AC bracket fan 400 mm (ISI marked,), min
3 star energy rating issued by BEE(if available in Indian market), grouting bolts & nuts, FR PVC insulated
multistranded single core copper conductor cable, connection to earthing system and as approved by Engineer. The
price also covers supply and erection of suitable clamps/brackets for fixing above.

33012: Supply, installation, testing and commissioning of stationary vertical storage type drinking water
cooler complete with Supply and installation of Auto Voltage Corrector.
The item price includes labour & cost of self contained drinking water cooler 150 litres capacity (cooling capacity
150 Lts. per hour) water cooler [conforming to IS-1475 (part-1)/2001], ISI marked, min 3 star rated, suitable for
operation on 230 volts+/-10%, 50Hz, AC supply system complete with all connected standard fittings, accessories
etc. and 5KVA , wall mounted, I.C. controlled electronic auto-voltage corrector conforming to relevant IS (latest
version), suitable for operation on single phase 180 to 260 volts, 50Hz incoming AC supply and output 200 to 230
volts A.C. supply, complete with time delay relay, voltmeter, instant start provision with push button switch, supply
and erection of earth electrodes and connection to earthing system etc as required.

Note:

(i) Price shall also covers supply & erection of suitable clamps/brackets for fixing of water coolers at Platforms,
Service buildings, sheds etc.

33013 (a), (b): Supplying, installation, testing and commissioning of LT Switch Boards different capacities

IFB No: RVNL/BSB/GEW/PEP-IAA,MAU-SHG/11

10
03/06/2018
ELECTRICAL GENERAL SERVICES/EXPLANATORY NOTES
The item price includes labour & cost of all materials including cost of LT switch board, connection of cables for
incoming and outgoing etc. LT switch board shall be cubical type, wall mounted, dust & vermin proof, conforming
to IS:8623 (latest version). LT switch board shall be suitable for operation on 3 phase, 4 wire, 415 volt, AC supply
system, fabricated with 16 SWG M.S. sheet, powder coated and complete with inter connections, instrument
connections with copper conductor cable, copper bus bars 200/250 amps. (as per capacity of switch board
63/125A), CT's, voltmeter, ammeter, LED type indication lights, cable glands, earthing studs etc.

Note: (i) LT Switch Board to be supplied as per RVNL specifications.


(ii) The price also covers supply and erection of suitable clamps/brackets for fixing above

33014: DELETED

33015 A to C: Supply, installation, testing and commissioning of L.T. Feeder pillars of different capacities

The item price includes labour & cost of all materials including cost of L.T. Feeder pillar, construction of brick
masonry platform 450 mm high, inter connections, connection of cables for incoming and outgoing etc. L.T. feeder
pillar shall be weather proof (degree of protection not less than IP54), fabricated with 2 mm thick CRCA sheet,
conforming to IS:8623 (latest version), powder coated, suitable for operation on 3 phase, 4 wire, 415 volt, AC
supply system., copper bus bars of 200/250/400 amps (as per capacity of feeder pillar 63/125/250A), LED type
indication lights, cable glands, earthing studs etc.

Note: (i) LT Fidder Piller to be supplied as per RVNL specifications.


(ii) The price also covers supply and erection of suitable clamps/brackets for fixing above

33016: DELETED

33017 (i),(ii), : Supply and erection of different length Tubular pole with Junction box etc.
The item price includes labour & cost of all materials including cost of swaged type steel Tubular pole 7 meters
long conforming to IS-2713 /Part I to III/1980 (latest version) (designation 410 SP – 3/ 410 SP - 30), canopy type
with suitable length and diameter brackets, Junction box, erection of pole, casting of foundation, muffing and
painting of pole, connection to the earthing system etc.

Entire Work shall be in conformity with IS2713/Part 1-3 and specifications of RVNL.

33018:DELETED
33019(i) to (v): Supply and erection of class ‘B’ G.I. Pipe with bends, accessories etc.
The item price includes labour & cost of G.I.Pipe class' B', ISI marked with bends, accessories etc.

33020(i) & (ii): Supply, installation, testing and commissioning of automatic changeover panel complete.
The item price includes labour & cost of all materials including cost of automatic changeover panel complete as
per RDSO specification No.TI/SPC/PSI/CLS/0020 (12/02) with A&C slips No. 1 to 4 or latest, connections as
required.
Note: Make of panel shall be on the approved list of manufacturers issued by RDSO/Lucknow.

33021:DELETED
IFB No: RVNL/BSB/GEW/PEP-IAA,MAU-SHG/11

11
03/06/2018
ELECTRICAL GENERAL SERVICES/EXPLANATORY NOTES
33022 (i) to (v): Supply, installation, testing and commissioning of 100/250/500 KVA Power Distribution
Transformer (energy efficiency level not less than–II), fencing and foundation
The item price includes labour & cost of all materials including cost of Transformer, erection testing and
commissioning as per standard code of practice as per IS 1180/2014 or latest with energy efficiency level not less
than II.
Extra payment shall be made for construction of foundation for transformer, providing fencing enclosure and
Iron Gate (if directed by the employer).
Requirements shall be as per details given here under:-
(a) Foundation

M10 grade cement concrete foundation shall be constructed with 20 mm coarse aggregate The size of foundation
shall be as per approved drawing based on size of transformer but shall not be less than 2 x1.5 mt (Length x
breadth) and 600mm above ground level duly plastered and finished surface. Curing shall be done as per code
applicable. Excavation shall be done complying with Code of Safety as per IS 3764/1992(Latest Version).

(b) Fencing

Fabrication of enclosure for housing transformer shall be made in rectangular formation as required with M.S.
Angle iron 50x50x8mm spaced at about 2 meters and 12 SWG GI wire mesh GI wire shall be cut according to size
and welded with the angle frame. MS strip not less than 15x3mm size shall be provided and welded above GI wire
along the angle frame to hold the GI wire mesh. Height of enclosure shall be 2 meter above ground level. The
portion of MS angle to be grouted in foundation shall be 500mm.
The fencing panels shall be erected on foundation constructed of size 200mmx200mmx500mm deep with cement,
& concrete of M10 grade.
(c) Iron Gate
Iron gate shall be fabricated with 50mm x 50mm x 8mm MS angle iron frame with iron grill etc.as approved. The
size of the gate shall be 2mt (height) x 3.5mt (width) and fabricated in two parts of 1.75 mt each. Gate shall be
provided with sliding Lockable bolt with Pad lock.
Gate shall be fixed on channels of size not less than100x50mm, weighing 7.90 Kg per meter with bolts & Nuts
and welded. Channels shall be erected on foundation constructed of size 300mmx300mmx500mm deep with
cement, concrete M10 grade
Complete enclosure including Gate and angles (except galvanized portion) shall be painted with approved shade
enamel paint over two coats of red oxide primer.
Installation shall be as per IS 10028 (Pt. II/1981) Latest Version.
Drawing of the enclosure with Iron Gate etc. shall be got approved from the Engineer.

33023: Supply, installation, testing and commissioning of 3 pole 11 KV, 400 amps Gang Operated Switch
complete with drop out fuses etc.
The item price includes labour & cost of all materials including cost of 3 poles 11 KV, 400amps. Gang Operated
Switch complete with drop out fuses, operation system, clamps, connections with ACSR conductor, sleeves, etc. as
required. All the materials used for manufacturing Gang Operated Switch shall conform to IS-2544, IS-5340 (Part-
III) and IS-9921 (Part-I to V).

IFB No: RVNL/BSB/GEW/PEP-IAA,MAU-SHG/11

12
03/06/2018
ELECTRICAL GENERAL SERVICES/EXPLANATORY NOTES
33024:Supply, installation, testing and commissioning of 11 KV 3 Panel HT Vacuum Circuit Breaker board
and end termination etc.
The item price includes labour & cost of all material including cost of 11 KV 3 Panel (one incoming and two
outgoings) HT VCB board, conforming to IS:13118/1991 & IS:3427/97, erection, testing, commissioning as per
RVNL specifications. VCB panel shall be 11kV, 350MVA, 630 Amps, draw out type, manually operated, 3 panel
HT VCB board comprising of 1 No. Incoming: 3 Pole, Vacuum Circuit Breaker complete with PT, relays, electronic
metering devices including ammeter, voltmeter, frequency meter, power factor meter and trivector meter (with 30
minutes integration) for maximum demand indicator of suitable range for unbalanced loads, clustered LED type
indication lights, double ratio copper wound current transformer (ratio 80/40/5A - for 500KVA & 60/30/5A for 250
KVA) and 2 Nos. Outgoing: 3 Pole, Vacuum Circuit Breaker complete with relays, Digital Ammeter, LED type
Indication light, double ratio copper wound current transformer ( ratio 60/30/5A- for 500KVA & 30/15/5A for 250
KVA) complete.

33025 & 33026: Supply, installation, testing and commissioning of LT Switch board.
The item price includes labour & cost of all material including cost of LT Switch board, erection, connections of
cables, testing, and commissioning etc. as per RVNL specifications. LT panel shall be cubical type, floor mounted,
dust & vermin proof, multi-tier construction, fabricated with 2mm thick CRCA sheet with base MS channel
100x50x7.5mm (nominal size), and powder coated. The LT switchboard shall conform to IS:8623 (latest version)
and shall be suitable for operation on 3 phase, 4 wire, 415 volt, AC supply system. The switch board shall be
complete with inter connections, instrument connections with copper conductor cable, copper bus bars, front
operated switchgears, selector switches, ammeter, voltmeter etc. on each incoming and ammeter on each outgoing
with LED type indication lights, cable glands, earthing studs etc. Each panel shall be in segregated compartment.

33027 &33028:DELETED

33029: Supply, installation, testing and commissioning of safety items in the substation.
The item price shall cover cost of fire extinguishing equipments (ISI marked), Rubber mat (ISI marked), GI fire
buckets filled with dry sand held on free standing steel stand, First aid box with medicines (ISI marked) and
associated materials, Shock treatment chart suitably laminated on aluminium frame, schematic diagram of HT &
LT installation & transformer data on white hylam sheet with aluminium frame & fixing/providing in the sub-
station area as directed by Engineer-in-charge of the work at site.

Stand for holding of fire buckets shall be free standing, manufactured with MS angle frame 50x50x6mm with base
angle frame, shade and hanging arrangements for buckets as per approved drawing.

Details of items are as under:

i) Fire extinguisher, dry chemical powder type (ISI marked) suitable for electric fire,10kg capacity - 2 Nos.

ii) Rubber mat (ISI marked) non-skid type suitable for 11kV AC supply of size 3600x1000x25mm - 2 nos.

iii) 6 nos. GI fire buckets of 10 Ltrs. capacity (24 gauge) duly fitted on MS angle 50x50x6mm stand, shade and filled w
clean dry ordinary sand -1set

IFB No: RVNL/BSB/GEW/PEP-IAA,MAU-SHG/11

13
03/06/2018
ELECTRICAL GENERAL SERVICES/EXPLANATORY NOTES
iv) First Aid Box (ISI marked) complete with medicines of approved make - 1 set

v) Electric shock treatment chart (large size) with aluminium frame and laminated as approved. - 2 Nos.

vi) 11kV/415 Volt danger plates conforming to relevant IS. - 8 Nos.


vii) Schematic diagram of HT/LT installation on white hylam sheet with aluminium frame of size 1200x600 m
computer printed and suitably laminated - 1 No.
viii) Data of transformer on white hylam sheet with aluminium frame of size 900x600mm. - 2 Nos.

33030 (i) to (iv): Supply, installation, testing &commissioning of DG set with acoustic enclosure with all other
accessories etc.
The item price includes labour & cost of all materials including cost of DG set with acoustic enclosure , AMF
panel and all other accessories, construction of plinth with materials as per OEM recommendations and approved
drawing, first filling of lubricating oil, supply of High speed Diesel oil required for testing, commissioning at site
etc as per details given in RVNL specifications. DG set shall be complete with diesel engine, copper wound
alternator, battery set, anti-vibration pads, fuel tank and all other accessories/equipments/protective devices etc and
AMF control panel conforming to relevant IS, fabricated with CRCA, 16 SWG sheet, powder coated and
comprising of incoming 4 pole, MCCB 50KA, 4 pole 800 Amps ACB (MDO) for 500 KVA DG Set, copper bus-
bars, 4 pole, heavy duty contactors, multifunction panel meter for display of current and voltage on phases and
lines, power factor, frequency, KWH, MD etc, LED indications lights including connections with single core 1.1
kV grade LT XLPE insulated copper conductor control cable between LT panel, AMF panel and alternator for auto
and manual operation etc.Noise level shall be less than 75-dBA averages or as per latest CPCB norms.

33031: Supply, installation, testing and commissioning of 125 KVAR APFC Panel.
The item price includes Supply, erection, testing & commissioning of 125 KVAR (10x12.5) Automatic Power
Factor Controller panel (capacitor bank) complete with low loss capacitors similar to MD-XL type of L&T make,
250 amp MCCB incomer (Ics=100%Icu), with auto and manual option, suitable for 3 phase, 415 Volt, 50 Hz AC
supply & switching ratio1:2:3:4, conforming to relevant IS (latest version). APFC Panel shall be similar to L&T
make cat.ref.A1256A10CMM. APFC panel shall be connected with the main panel as per site requirement.
Cable for providing connections are payable under relevant BOQ item.

33032:Earthing with 3 meter long, 50 mm dia G.I. Pipe class 'B' earthing electrode.

The item price includes labour & cost of all materials including cost of GI pipe, concrete enclosure, MS cover plate
with lifting handle, charcoal/coke and salt, etc.
Earthing shall be in conformity to IS 3043/1987 (Latest Version) and as per approved drawing. Excavation shall be
done complying with Code of Safety as per IS 3764/1992(Latest Version). Earth resistance shall not be greater than
5 ohm in normal soil and 8 ohm in rocky area.

33033: Earthing with 600mmx600mmx6mm G.I. earth plate

The item price includes labour & cost of all material including cost of supply of GI earth Plate, concrete enclosure,
MS cover plate with lifting handle, G. I. watering pipe, charcoal or coke and salt etc. The price shall also cover
erection including digging of earth pit in any kind of soil at the specified location. The work shall also cover the
earth treated to obtain earth resistance of less than 1 ohm. Connection of earth electrode should be made by
providing GI clamps nuts, bolts.

IFB No: RVNL/BSB/GEW/PEP-IAA,MAU-SHG/11

14
03/06/2018
ELECTRICAL GENERAL SERVICES/EXPLANATORY NOTES
Work shall be in conformity to IS 3043/1987 (Latest Version) and as per approved drawing. Excavation shall be
done complying with Code of Safety as per IS 3764/1992. Earth resistance shall not be greater than 1 ohm in normal
soil and 2 ohm in rocky area.
Payment of G.I. strips to be laid for connections are payable under relevant BOQ item
33034: Earthing with 600mmx600mmx3mm thick copper plate earth plate
The item price includes labour & cost of all material including cost of supply of copper earth Plate, concrete
enclosure, MS cover plate with lifting handle, G. I. watering pipe, charcoal or coke and salt etc. The price shall
also cover erection including digging of earth pit in any kind of soil at the specified location. The work shall also
cover the earth treated to obtain earth resistance of less than 1 ohm. Connection of earth electrode should be made
by providing cadmium plated brass bolts & nuts. Earth resistance shall not be greater than 1 ohm in normal soil and
2 ohm in rocky area.

Work shall be in conformity to IS 3043/1987 (Latest Version) and as per approved drawing. Excavation shall be
done complying with Code of Safety as per IS 3764/1992

Payment of copper strips to be laid for connections are payable under relevant BOQ item.

33035 (i&ii):Supply and laying of G.I. strip below ground or surface/in recess.
The item price includes labour & cost of all materials including cost of G.I. strip on surface or recess or digging in
ground/making chase in wall/floor and making good the damages, connections including soldering/riveting etc as
required.

33035 (iii)Supply and laying copper strip on surface or in recess or in 50 mm dia G.I. pipe
The item price includes labour & cost of all materials including cost of copper strip on surface or recess or digging
in ground 0.50 meter below ground/ making suitable holding arrangements on transformer /D.G. Set end, making
good the damages, Connections of strip includingsoldering/riveting etc as required.

Rates for G.I.pipe are payable separately under relevant BOQ item.

33036(i) to (xi): Supply, laying, testing and commissioning of LT cable.


The item price includes labour & cost of all material including cost of LT XLPE cable conforming to IS:7098/Pt I
(latest version), bricks, sand, cement, termination lugs/crimping socket, including fixing. Inscription on the plate
shall be as specified in RVNL tech. spec. Cable markers shall be provided as instructed by Engineer at not more
than 50 m interval and at locations where cable route is changing or cable joint provided.

In substation area, laying of cable includes construction of suitable trench. Trench shall be filled with dry sand up
to 300 mm above the cable after it is laid. ‘U’ frame shall be manufactured with MS angle 50x50x6mm & grouted
vertical in floor for holding cable on transformer end. Cable shall be held vertical with clamps of MS flat 50x6mm
at two places on frame on transformer and panel side. Painting of U’ frame and clamps shall be done with approved
shade paint. Cables shall be terminated with LT panel & on the transformer side with aluminium crimping sockets
& tested and commissioned as required.

The price covers laying of cable in all Cables in all types of piping , horizontally & vertically , underground on
wall, in air or under the Rly track or Road wherever required.

Cables on vertical wall shall be fixed with clamps of MS flat 50x6 mm with all fixing accessories.

IFB No: RVNL/BSB/GEW/PEP-IAA,MAU-SHG/11

15
03/06/2018
ELECTRICAL GENERAL SERVICES/EXPLANATORY NOTES
Rates for RCC/G.I/HDPE pipe are payable separately under relevant BOQ item.

Rates for cable route markers (MS or RFID type) are payable separately under relevant BOQ item.

33037 (i , ii & iii): Supply and erection of high mast system complete with accessories,
The item price includes labour & cost of Supply, erection, testing & commissioning of hot dipped galvanised (inside
& outside), 16m /12 m /25mhigh mast system (in two sections), complete with accessories, foundation bolts with
nuts, washers, anchor plates & templates etc. manufactured from special steel, head frame, 2-point suspension
system with steel wire rope 6mm dia (7/19 construction), double drum winch, galvanised lantern carriage
arrangement suitable for required luminaries symmetrically arranged & control gear boxes and lighting finial etc.
The mast shall have integral type power tool at the base compartment for its raising and lowering operation, twin
dome aviation obstruction lights with 100 watt lamp, control panel etc.

Control panel shall consist of:

(a) 1X63 A TPN MCB for incoming supply


(b) 3X32 A SPN MCB for outgoing (50% lighting, 100% lighting, motor)
(c) Automatic timer with contactor for controlling above lights of suitable capacity.
(d) 1 no multi plug socket 16A
High mast shall be provided with fencing panel of size 2Mx2Mx1.5M in square shape for protection of erected high
mast tower wherever required as directed by Engineer. The cost shall also include construction of foundation as per
recommendation of manufacturer and approved drawing and its fixing arrangements etc.

Note:1. Pipe electrode earthing is payable extra under relevant BOQ Item.
2. LED type flood light luminaries are payable separately under relevant BOQ Item.

33038 (i) to (iv):Supply, laying, testing and commissioning of 33 /11 KV XLPE (E) insulated, armoured
aluminium conductor cable.
The item price includes the cost of supply of cable conforming to IS:7098/Pt.II/85 and all other materials including
bricks, sand and cement. The item price also includes laying of cable, , miscellaneous works such as digging of
trench, provision of suitable clamps as per site requirements and testing & commissioning. Price covers Laying of
cable in all type of pipes, horizontally or vertically, underground, on wall or in air or under the Railway track/road
wherever required. It also includes coordination for arranging shut down from state Electricity authorities and
returning/ transporting of released materials to state electricity authorities.
In substation area, laying of cable includes construction of suitable trench. Trench shall be filled with dry sand up
to 300 mm above cable after laying. ‘U’ frame shall be manufactured with MS angle 50x50x6mm & grouted vertical
in floor for holding cable on transformer and HT panel end. Cable shall be held vertical with clamps of MS flat
50x6mm at two places on frame on transformer and panel side. Painting of U’ frames and clamps shall be done
with approved shade paint.
IFB No: RVNL/BSB/GEW/PEP-IAA,MAU-SHG/11

16
03/06/2018
ELECTRICAL GENERAL SERVICES/EXPLANATORY NOTES
The cable shall be laid as per RVNL’s technical specifications.
The cost of GI/RCC/HDPE pipe and cable route markers is payable under separate BOQ items.

33039(i): Supply and erection of RFID based electronic Cable/pipe marker.


The item price includes cost of supply and erection of RFID based electronic Cable/pipe marker of reputed make
suitable to work upto 1.5m depth, min dia of 22 CMs, having inbuilt GPS module for storing GPS coordinates, each
marker identification with 10 digits Hexadecimal Code, 134.0 KHZ frequency with self generated power source
having capability to receive signals and transmit back. Marker to be similar to Smart RFID marker SM 1500 or
superior as approved by Engineer.

33039 (ii):CABLE ROUTE MARKER-MS TYPE


The item price includes labour & cost of all materials including cost of cable route markers of size not less than
200x150x3mm thick M.S.Plate and welded to MS rod of min 5 mm dia including bending and fixing with the cable.

33040 (i) & (ii): Supply, termination, testing & commissioning of 33 KV/11KV outdoor types, heat shrinkable
end termination kit.
The item price includes labour & cost of all materials including cost of 33KV/11KV outdoor type, heat shrinkable
end termination kit, making termination and connecting to the overhead lines.

33041: Supply, Erection and commissioning of RFID cable marker locater.


The item price includes cost of supply, erection, testing and commissioning of RFID Marker locator, 1.5m Depth
Range, capable of acquiring and storing min 8000 RFID marker records, having built in GPS Module for logging
GPS coordinates and audio guidance for operator to navigate to locations of RFID markers, LCD/LED Display,
data port to allow data output to PC with marker database software. Similar to Smart RFID marker locator
Energy/SML or superior as approved by Engineer.

33042 (i): Supplying and erection of pre-stressed, cement concrete (PSCC)/RSJ double pole structure 9-11
meters long complete with galvanized stay set, anti climbing devices and fixing of Danger plates on the
erected pole.
The item price includes coordination with SEB/concerned authorities, labour & cost of all materials including cost
of pre-stressed, cement concrete (PSCC)/RSJ (As per site requirement) double pole structure(H-pole) 9-11 meters
long, 4 nos. channel cross arms & 2 nos cross bracing angles, clamps, bolts, nuts etc. including erection, casting of
foundation , muffing etc. The item price also includes supply and erection of galvanized stay set with 19/20 mm
dia x1.8 meters long stay rod, anchor plate of size 45cm.x45cm x 7.5mm thick, thimble, stay clamp of galvanised
MS flat 50 x 6 mm, turn buckle (20mmx600 mm), 7/4.00 mm dia G I stay wire conforming to IS 2141-1968, 11KV
strain insulators etc. including digging of pit, casting of foundation for poles & stays with cement, concrete M10
grade and refilling, supply and erection of anti climbing devices, and danger plates on the erected poles. Above
items are for guidelines purpose. The entire work has to be done in coordination and as per standards of concerned
State Electricity Board.

33042 (ii): Supply of material, fabrication and erection of ‘H’ pole structure 9 to 11 meters long complete
with galvanized stay set, anti climbing devices and fixing of Danger plates on the erected pole.
The item price includes coordination with SEB/concerned authorities, labour & cost of all materials including cost
of fabrication & erection of 9 to 11 meters long ‘H’ pole fabricated from I section MS Beam ISHB 150mm x
150mm (weight not less than 27.1 kg/meter, Tolerance as per Relevant IS permitted). The ‘H’ poles shall be

IFB No: RVNL/BSB/GEW/PEP-IAA,MAU-SHG/11

17
03/06/2018
ELECTRICAL GENERAL SERVICES/EXPLANATORY NOTES
fabricated as directed by Engineer and drawing approved by RVNL, Railway and SEBs. Drawing shall be made by
contractor and get it approved from concerned authorities before taking up the work. The guiding details of the
poles are:
Cross bracing of M.S. angle size 65x65x6mm (Total length of different pieces should be greater than 0.3 meter
from length of pole), 4 nos. channel cross arms & 2 nos cross bracing angles, clamps, bolts, nuts etc. including
erection, casting of foundation , muffing etc. The item price also includes supply and erection of galvanized stay
set with 19/20 mm dia x1.8 meters long stay rod, anchor plate of size 45cm.x45cm x 7.5mm thick, thimble, stay
clamp of galvanised MS flat 50 x 6 mm, turn buckle (20mmx600 mm), 7/4.00 mm dia G I stay wire conforming
to IS 2141-1968, 11KV strain insulators etc. including digging of pit, casting of foundation for poles & stays with
cement, M15 grade and refilling, supply and erection of anti climbing devices, and danger plates on the erected
poles. The contractor shall have to erect the ‘H’ pole structure, terminate and connect the existing/new HT line and
commission complete in all respect.

Above items are for guidelines purpose. The entire work has to be done in coordination and as per standards of
concerned State Electricity Board ready for their final acceptance/handing over.

33043: Supply and erection of 11 KV Porcelain Disc insulators complete with galvanized iron hardware etc.
including terminating with 11KV/ 33 KV overhead conductors as required.
The item price includes labour & cost of all materials including cost of 11 KV porcelain Disc insulators complete
with galvanized iron hardware, terminations with overhead with PG clamps, dismantling of materials transporting
and handing over to concerned authorities wherever required, etc.

33044 (a): Supply and laying of HDPE pipe DWC/Split DWC pipe under the Railway track /Road, size
200/175 mm.
The item price includes labour & cost of all materials including cost of HDPE pipe DWC/split, conforming IS:
14930 (Part 2:2001), Non metallic, corrugated, multiwalled, normal duty, pliable, without protection against
chemical attack & non flame propagating in 6 M length of size 200 mm outer dia grade PN4 and PE80 (permitted
tolerance in dia = +/- 2mm), digging of trench, laying of pipe and back filling of trench with excavated earth etc.

Prior to start of excavation works under track/road, proper permission shall be obtained from the concerned
authorities.

33044(b):Supply and laying of HDPE pipe DWC/split DWC pipe under the Railway track /Road with trench
less method, size 200/175 mm.
The item price includes labour & cost of all materials including cost of HDPE pipe DWC/split, conforming IS:
14930 (Part 2:2001), Non metallic, corrugated, multi walled, normal duty, pliable, without protection against
chemical attack & non flame propagating in 6 M length of size 200 mm outer dia grade PN4 and PE80 ( permitted
tolerance in dia = +/- 2mm), making trench with trench less method with suitable machines etc and making good
the damages.

Prior to start of works, proper permission shall be obtained from the concerned authorities.

IFB No: RVNL/BSB/GEW/PEP-IAA,MAU-SHG/11

18
03/06/2018
ELECTRICAL GENERAL SERVICES/EXPLANATORY NOTES
Due care should be taken to avoid damage to tracks alignment, existing cables, pipes or other such installations
during Drilling/Boring. Horizontal distance of the proposed trench from the existing and proposed electric mast
shall not be less than 5.0 meters and shall be away from the track joints.

33044 (c): Supply and laying of HDPE pipe DWC/Split DWC pipe under the Railway track /Road, size 63/50
mm.
The item price includes labour & cost of all materials including cost of HDPE pipe DWC/split, conforming IS:
14930 (Part 2:2001), Non metallic, corrugated, multi walled, normal duty, pliable, without protection against
chemical attack & non flame propagating in 6 M length of size 63 mm outer dia grade PN4 and PE80 (permitted
tolerance in dia = +/- 2mm), digging of trench, laying of pipe and back filling of trench with excavated earth etc.

Prior to start of excavation works under track/road, proper permission shall be obtained from the concerned
authorities.

33044 (d): Supply and laying of HDPE pipe DWC/split DWC pipe under the Railway track /Road with
trench less method, size 63/50 mm.
The item price includes labour & cost of all materials including cost of HDPE pipe DWC/split, conforming IS:
14930 (Part 2:2001), Non metallic, corrugated, multi walled, normal duty, pliable, without protection against
chemical attack & non flame propagating in 6 M length of size 63 mm outer dia grade PN4 and PE80 , making
trench with trench less method with suitable machines etc and making good the damages.

Prior to start of works, proper permission shall be obtained from the concerned authorities.

Due care should be taken to avoid damage to tracks alignment, existing cables, pipes or other such installations
during Drilling/Boring. Horizontal distance of the proposed trench from the existing and proposed electric mast
shall not be less than 5.0 meters and shall be away from the track joints.

33044 (e): Supply and laying of HDPE pipe DWC/Split DWC pipe under the Railway track /Road, size 63/50
mm.
The item price includes labour & cost of all materials including cost of HDPE pipe DWC/split, conforming IS:
14930 (Part 2:2001), Non metallic, corrugated, multi walled, normal duty, pliable, without protection against
chemical attack & non flame propagating in 6 M length of size 110 mm outer dia grade PN4 and PE80, digging of
trench, laying of pipe and back filling of trench with excavated earth etc.

Prior to start of excavation works under track/road, proper permission shall be obtained from the concerned
authorities.

33044 (f): Supply and laying of HDPE pipe DWC/split DWC pipe under the Railway track /Road with trench
less method, size 63/50 mm.
The item price includes labour & cost of all materials including cost of HDPE pipe DWC/split, conforming IS:
14930 (Part 2:2001), Non metallic, corrugated, multiwalled, normal duty, pliable, without protection against
chemical attack & non flame propagating in 6 M length of size 110 mm outer dia grade PN4 and PE80, making
trench with trench less method with suitable machines etc and making good the damages.

IFB No: RVNL/BSB/GEW/PEP-IAA,MAU-SHG/11

19
03/06/2018
ELECTRICAL GENERAL SERVICES/EXPLANATORY NOTES
Prior to start of works, proper permission shall be obtained from the concerned authorities.

Due care should be taken to avoid damage to tracks alignment, existing cables, pipes or other such installations
during Drilling/Boring. Horizontal distance of the proposed trench from the existing and proposed electric mast
shall not be less than 5.0 meters and shall be away from the track joints.

33044 (g): Supply and laying of HDPE pipe DWC/Split DWC pipe under the Railway track /Road, size 63/50
mm.
The item price includes labour & cost of all materials including cost of HDPE pipe DWC/split, conforming IS:
14930 (Part 2:2001), Non metallic, corrugated, multiwalled, normal duty, pliable, without protection against
chemical attack & non flame propagating in 6 M length of size 160 mm outer dia grade PN4 and PE80, digging of
trench, laying of pipe and back filling of trench with excavated earth etc.

Prior to start of excavation works under track/road, proper permission shall be obtained from the concerned
authorities.

33044 (h)Supply and laying of HDPE pipe DWC/split DWC pipe under the Railway track /Road with trench
less method, size 63/50 mm.
The item price includes labour & cost of all materials including cost of HDPE pipe DWC/split, conforming IS:
14930 (Part 2:2001), Non metallic, corrugated, multiwalled, normal duty, pliable, without protection against
chemical attack & non flame propagating in 6 M length of size 160 mm outer dia grade PN4 and PE80, making
trench with trench less method with suitable machines etc and making good the damages.

Prior to start of works, proper permission shall be obtained from the concerned authorities.

Due care should be taken to avoid damage to tracks alignment, existing cables, pipes or other such installations
during Drilling/Boring. Horizontal distance of the proposed trench from the existing and proposed electric mast
shall not be less than 5.0 meters and shall be away from the track joints.

33044(i) & (j):Extra on 33044 (a) to (h) for hard soil / soft rock locations
Extra price for execution in hard soil / soft rock for items 33044(a) to (h)
33045 (i & ii): Supply, installation, testing & commissioning of Submersible pump set, control panel etc.
The item price includes labour & cost of all material including cost of Submersible pump set ISI marked and min
3 star energy rating with control panel, cable etc suitable for supplying water at required head and discharge as per
site conditions and as directed by Engineer. The horse power of the motor is approximate. Suitable motor has to be
installed keeping in view the site conditions. However, all items required for the safe and efficient operation whether
stated or not, shall be deemed to be included. Control panel shall be wall mounted cubicle type, dust & vermin
proof, suitable for operation on 415 volts AC supply system, with degree of protection not less than IP 54, fabricated
with 16SWG thick CRCA sheet steel, duly powder coated.

Details of accessories etc are as under:-

1 Flat, water submersible, 3 core cable of size as recommended by


the manufacturer and of the required length.
2 Cable ties for clamping of flat cable to pipe at every 1 mtr interval
throughout the length.

IFB No: RVNL/BSB/GEW/PEP-IAA,MAU-SHG/11

20
03/06/2018
ELECTRICAL GENERAL SERVICES/EXPLANATORY NOTES
3 Two pairs of MS suspension clamps made of suitable size of MS
flat - 1 set.
4 Full way valve of suitable size ISI mark - 1 No.
5 Pressure gauge of required capacity - 1 No.
6 Bore cover - 1 No.
7 GI bend of suitable size - as required
8 BCH/L&T make Cubicle type, weather proof control panel with
degree of protection not less than IP54, complete with the
following :-
i) TPN MCB 32A 10kA - 1 No.
ii) Direct On Line starter (DOL) suitable to the above - 1 No.
iii) Suitable pump set measurement and protection system as
approved by engineer - 1 set
iv) MINILEC current based dry run protection - 1 No.
v) Suitable capacitors to improve PF to min 0.99.
33046: Co-ordination/ Liaisoning and chasing with State Electricity Board authorities for availing New
Electric Connection / augmentation of load/modification of crossings etc.
The item price includes cost for Co-ordination/Liasoning /chasing with State Electricity Board authorities for
various activities involved for availing new connections, augmentation of loads, including collection of estimates
for New connections, additional load & crossings modifications, arranging payment from RVNL, depositing
payment to SEB's authority, release of load & other connected works etc.as required.

Note: Payments made for application forms will be reimbursed by RVNL on proof of documents.

33047: Design and preparation of working & completion drawings of the installations.
The item price includes cost for design of electrical works and preparation of working & completion drawings of
the installations covered under general electrical services work of the complete project including internal
electrification of quarters, level crossings, station buildings, offices, buildings, Power line crossings, Power supply
distribution arrangements of stations with platform lightings, sub stations, Electrification of Sub stations building,
etc as required on Auto Cad & arranging approval from competent authority.
On award of contract, survey of all the installations (Excluding Power line crossings which are covered under other
BOQ item)shall be carried out and drawings indicating existing & proposed works, schematic layout /arrangements
etc. shall be prepared on Auto Cad based on Zonal Railway’s and SEB’s norms & requirements and shall begot
approved from the competent authorities i.e. RVNL/Zonal Railways/SEB’s etc. as required. All the drawings shall
be speaking with conventional signs and symbols.
After completion of entire work, as executed drawings shall be prepared and supplied while handing over the
completed works to the Zonal Railways.

Design and Drawings will be the property of Railways.


Following drawings shall be prepared and submitted.
WORKING DRAWINGS

1 Soft Copy One set of each drawing prepared on Autocadand pdf scanned.

2 Hard Copy one copy on non-tearable tracing (Engineering matte film of 75 micron or more
thickness) and four sets on paper

COMPLETION DRAWINGS

IFB No: RVNL/BSB/GEW/PEP-IAA,MAU-SHG/11

21
03/06/2018
ELECTRICAL GENERAL SERVICES/EXPLANATORY NOTES
1 Soft Copy One set of each drawing prepared on Autocadand pdf scanned.

2 Hard Copy Onecopy of each drawing of not less than A-3 size on RTF (Re-
producible Tracing Film), one copy on non-tearable tracing
(Engineering matte film of 75 micron or more thickness) and
four sets on paper.

NOTES:
1) Drawing for all HT installations are to be got approved from the Chief Electrical Engineer of the Zonal railway
in his capacity as Electrical Inspector to Govt.of India.
2) Drawings for LT/11kV/33kV crossings of State Utility Company, that are being modified, are to be got approved
from the concerned Utility Company, prior to taking up the work.

33048:Conducting check survey for the existing LT, HT and EHT Power line Electrical crossings on the
section and measurements of clearances to identify modification required/not required
The item price includes cost for conducting check survey of complete section for all the existing LT, HT and EHT
Power line Electrical crossings, power lines running parallel to track from the proposed track route and requiring
modification keeping in view Regulations for Electrical crossing of Railway Track 1987 and IRSOD-2004 with
latest amendments , measurements of horizontal distances of structures (up to next two structures on each side)
from the existing & proposed tracks etc, vertical clearances of lowest conductors & guard wires from existing &
proposed rail level, angle of crossings, height and type of towers/poles, preparation of “list of crossings requiring
modification” & “ list of crossings not requiring modifications” etc. (Height/ clearances shall be accurate with zero
tolerances)
Measurements shall be recorded on a format as approved and be submitted considering all aspects including details
required as indicated above. Proposal for modification arrangement of infringing power line crossing shall also be
submitted.

33049:Supply, erection, testing & commissioning of outdoor type, single side and double side Glow sign board
/Pictorial signage board with suspension/ mounting arrangement.
The item price includes Supply, installation, testing & commissioning of outdoor type, single side, /Double side
Glow sign boards/Pictorial signage boards with suspension /side mounting/wall mounting type arrangements as
required, complete including internal wiring with 2x1.5sq mm FR PVC insulated, multistrand, copper conductor
single core cable on surface PVC conduit, earthing with 1.5 sq mm FR PVC insulated multi strand copper
conductor single core cable conforming to IS 694(latest version) etc, acrylic sheet of thickness not less than 4mm
on front side, G.I /Aluminium Sheet of 24 SWG on all 5 / 4 sides with louvers etc.as required. Depth of board
shall not be less than 200mm. Erection arrangement shall be as approved by Railways. Matter to be written /
displayed on signboards shall be got approved before manufacturing of board. Glow sign board shall have degree
of protection not less than IP 54.

Prewired 18-20 watts LED fitting (4 feet) 1x28 watt complete with electronic ballast etc. shall be provided.
Provision of Nos. of luminary shall be based on one No.18-20 watts LED fitting (4 feet) per 8 Sq. ft area.

Note: 1. Boards of smaller dimensions/area which may not accommodate 28 watt luminary shall be provided
with 1x14 watt luminary per 4 sq.feet area.
2. Payment for Double sided glow sign board shall be made @ 150% of the total rate of single sided
glow sign boards.
Wiring shall conform to relevant IS and code of practice as applicable.
IFB No: RVNL/BSB/GEW/PEP-IAA,MAU-SHG/11

22
03/06/2018
ELECTRICAL GENERAL SERVICES/EXPLANATORY NOTES

33050: Supply, installation, testing & commissioning of Silicon rectifier battery charging set 200 Amps
capacity including connections.
The item price includes labour & cost of all materials including cost of battery charging set as per RVNL tech
specifications. Payment for L.T. cable shall be made under relevant BOQ item.
33051: Supply, erection, testing and commissioning of weather proof, outdoor type, dust and vermin, floor
mounted, 110 volts battery charging point.
110 V DC battery charging points shall be manufactured as per RVNL technical specification OR as per approved
Drawing of Zonal Railway / RVNL.

The item price includes labour & cost of all material including cost of Fabrication, supply, installation, testing and
commissioning of cubicle type, weather proof, outdoor type, dust & vermin proof, 110 volts Battery charging point
conforming to IS 8623 (latest version) with degree of protection not less than IP54. Battery Charging point shall be
suitable for operation on 150 volts DC supply system and fabricated with 14 SWG galvanised MS sheet, M.S.
channel size 100x50mm (weight 7.914kg/metre) 1200mm long, powder coated, inter-connections with single core,
PVC insulated, multi stranded, copper conductor cable of size 10 sq.mm, 3 nos. aluminium bus bar of size
25x10mm, complete with one no. MCB DP 63 Amps (DC series) 10kA, including vertical grouting of channel
300mm deep in ground for erection with cement concrete M10 grade as per standard drawing of Zonal railway/as
approved by the Engineer.
33052: Supply, erection, testing & commissioning of weather proof, dust & vermin proof, Pre-cooling point.
The item price includes labour & cost of all material including cost of Fabrication, supply, installation, testing and
commissioning of cubicle type, weather proof, outdoor type, dust & vermin proof, pre- cooling point conforming
to IS 8623 (latest version) with degree of protection not less than IP54. Pre-cooling point shall be manufactured
with 3.15mm CRCA sheet with 4 pedestals (on corners) of M.S. angle size 65x65x8mm (900mm long) with base
frame of M.S. angle size 40x40x5mm, duly powder coated including vertical grouting of MS. angles 300mm deep
in ground for erection with cement concrete M10 grade as per standard
drawing of Zonal railway/as approved by the Engineer. Pre-cooling point shall be complete including following:.

i) One no. 100 A, 4 pole, MCCB 35 kA (Fixed type )


ii) One no. 63A industrial type, iron clad 5 pin (3P +N+E) 415 V plug socket with spring locked cover.
iii) One No. 32 A Industrial type iron clad 3 pin (P+N+E) 250 V plug socket with spring locked cover.
iv) Batten Holder fixed on Bakelite sheet base plate with suitable lamp and controlled by 5 A piano type
switch.
v) 300 A Aluminium bus bar for Phases & 200 A for Neutral, with epoxy coating/ PVC colour coded
sleeves.
vi) Cable entry glands of suitable size
vi) LED indication lights.
The connections from bus bars to MCCB and from MCCB to the feeding terminal (Iron Clad Sockets) shall be done
with single core, copper conductor cable of suitable rating with suitably sized galvanized MS bolts, nuts and
washers.
Fluorescent screen printed indication plates on the front shall be provided for clear indication of 415 Volts, AC pre-
cooling point.
Pre cooling points shall be manufactured as per RVNL technical specification OR as per approved Drawing of
Zonal Railway / RVNL.

33053:Dismantling of wiring installations


The item price includes cost of labour for dismantling of complete electrical/solar and wiring installations as per
site conditions, stocking, accountal, transporting and handing over the released material to electrical department.

IFB No: RVNL/BSB/GEW/PEP-IAA,MAU-SHG/11

23
03/06/2018
ELECTRICAL GENERAL SERVICES/EXPLANATORY NOTES
Buildings, offices, sheds, gate lodges etc. infringing the new works may also require dismantling of Electrical
installations.
The item covers dismantling of wiring installation, lamp /tube fittings, street light fittings, fans, Distribution boards,
mains, sub mains, L.T.Panel(s), solar panels and associated cables etc and other such accessories of Railway station
building/service building/sheds/gate lodges etc, removal from site, transportation or shifting to new location and
handing over of released materials to Electrical department as instructed and if required making temporary
arrangements as per instructions of the engineer.
33054 (i): Dismantling of erected pole and its associated overhead conductor, GI wire, cross arms brackets,
insulators, Stay, luminary.
The item price includes cost of labour for dismantling of erected pole and its associated overhead conductor, GI
wire, cross arms brackets, insulators, Stay, luminary etc as are at site including stocking , transporting and handing
over released material to concerned official as instructed and if required making temporary arrangements as per
instructions of the engineer.

33054 (ii): Dismantling of Sub Station Equipments.


Dismantling of Sub Station Equipments including Transformers, DG Sets, HT & LT Panels, cables, etc as are at
site including stocking , transporting and handing over to concerned official as instructed. Prior to dismantling of
work, it shall be ensured that the temporary power supply to the feeders shall be arranged to meet the requirements
as per instructions of the engineer.

33055 (i&ii) :Providing temporary wiring/cabling arrangements for lights & fans with stand by D.G.Sets.
The item price includes labour & cost of all materials required for temporary arrangements in adequate quantity
distributed over entire station area as decided by the engineer including wiring, cabling, luminaries with lamps,
Pedestal fans, cost of consumables for replacement, deployment of staff for maintaining temporary arrangements
during pre/post/during non - interlocking period as required, arrangement of DG sets for Power supply to temporary
installations including operation and Supply of required Diesel oil, lube oil,, provision of earthing arrangement as
required.

D.G. Sets including spare DG set should be of suitable capacity as decided by Engineer in charge to meet the load
required during non interlocking period.

Work of temporary wiring installation shall comply with latest code of practices and IE. Rules.

After completion of requirements of non interlocking work, installation shall be dismantled and material shall be
taken away from the site as directed by the Engineer.

NOTE: Normal power supply, if spare load is available, may be used up to sanctioned load with prior approval
free of cost.

33056 (a), (b): Supply, installation, testing and commissioning of 1.5/2.0 Tonne window type A.C. unit with
Auto Voltage Corrector.
The item price includes labour & cost of Supply, installation, testing and commissioning of window type A.C. Unit,
ISI marked and min 3 star energy rated conforming to IS-1391 Pt-I/1992 (amdt 1,2), complete with LCD display
cordless remote (for control of functions, on/off, timer, selecting fan speed (three speeds) and setting up of
temperature), rotary compressor, 3/3 speed cooling/fan, air ventilator, air bacteria filter, condenser (type - GOLD),
suitable for 1-phase 230 ± 10% voltage AC supply including supply & installation of suitable rating, wall mounted,
I.C. controlled electronic auto voltage corrector conforming to relevant IS (latest version), suitable for operation on
IFB No: RVNL/BSB/GEW/PEP-IAA,MAU-SHG/11

24
03/06/2018
ELECTRICAL GENERAL SERVICES/EXPLANATORY NOTES
single phase 180 to 260 volts, 50 Hz incoming AC supply and output 200 to 230 volts A.C supply, with time delay
relay, voltmeter, instant start provision with push button switch, earthing etc as required.

NOTE: AC unit shall be fixed in the space available and shall be provided with the frame in approved manner
(polished hard wood or other material as approved).

33056 (c), (d): Supply, installation, testing, & commissioning of Split type, 1.5 /2.0 Tonne Cap. AC unit
inverter type and Auto Voltage Corrector.
The item price includes of Supply, installation, testing and commissioning of split type A.C.Unit, inverter type, ISI
marked and min 3 star energy rated conforming to IS-1391 Pt-II/1992 (amdt 1), complete with LCD display,
cordless remote [for control of functions, on/off, timer, selecting fan speed (three speeds) and setting up of
temperature], rotary compressor, 3/3 speed cooling/fan, air ventilator, air bacteria filter, condenser (type - GOLD),
suitable for 1-phase 230 ± 10% voltage AC supply complete with stand (as approved) for fixing outdoor unit,
provision of rubber pads below the outdoor unit, heavy duty PVC flexible pipe (ISI marked) for drain,
interconnecting cable and refrigerant copper pipes with thermal insulation, including supply & installation of
suitable rating, , wall mounted, I.C. controlled electronic auto voltage corrector conforming to relevant IS (latest
version), suitable for operation on single phase 180 to 260 volts, 50 Hz incoming AC supply and output 200 to 230
volts A.C supply, with time delay relay, voltmeter, instant start provision with push button switch, earthing etc as
required.

The item price also includes labour & cost of extra copper refrigerant pipes with insulation as required (in addition
to standard length supplied with the unit), electric cable for connection etc as required.

33057(i) to (iv): SUPPLY & ERECTION OF G.I. OCTAGONAL POLE


Item price includes labour & cost of all materials including cost of G.I. octagonal pole, single/Double arm bracket,
foundation etc as per details given in RVNL tech specifications.

33058(i) to (iii): Supply, installation, testing & commissioning of cubical type, Mast mounted, dust & vermin
proof, L.T control switch board for AT.
Item price includes supply, installation, testing & commissioning of L.T control switch boardfor AT. Switch board
shall be cubical type mast mounted, dust & vermin proof, conforming to IS:8623 (latest version), suitable for
operation on single phase, 2 wire, 415 volt, AC supply system, fabricated with 16 SWG, CRCA sheet, powder
coated and complete with inter connections with copper conductor cable, copper bus bars in bus chamber, clustered
LED type indication lights, cable glands for incoming and outgoing clamping with mast with 50x50x6 mm MS flat
clamps, earth studs etc., complete with TPN MCCB, copper busbars etc. as per details given in RVNL tech
specifications.

33059: Fifteen(15) W LED TYPE SOLAR STREET LIGHT


Item price includes supply, erection, testing & commissioning of 15 W LED solar street light system complete with
solar panels, battery, control gear, 6 m GI pole. The control gear shall include features for automatic switching ON
& OFF of street light according to day light. Battery shall have at least 3 days backup to cater for cloudy days.
Battery shall be maintenance free type. As approved by engineer.

Make : Tata, Phillips, Bajaj, Havell’s, CGL, Microtech, Sukam

IFB No: RVNL/BSB/GEW/PEP-IAA,MAU-SHG/11

25
03/06/2018
ELECTRICAL GENERAL SERVICES/EXPLANATORY NOTES
33060: SOLAR WATER HEATING SYSTEM
Item price includes labour & cost of all materials/equipments including cost of solar street lighting system complete
with pole, luminary with CFL, SPV module, Battery with MS Battery box, cables etc and construction of foundation
of pole as per RVNL specifications and as approved by engineer.

33061:DESIGN,SUPPLY,ERECTION AND COMMISSIONING OF GRID CONNECTED SOLAR


POWER PLANT CONSISTING OF SOLAR PANELS,PCU MOUNTING STRUCTURES AND ALL
OTHER ASSOCIATED EQUIPMENTS AS PER RDSO/PE/SPEC/PS/0092-2008(REV 0) WITH LATEST
AMMENDMENT
The general scope under this contract includes design with site survey, manufacture, testing, inspection,
transportation, erection, carrying out preliminary tests at site, commissioning, performance testing and handing
over to Railway authority all the equipment installed for grid connected 400 KWP SPV Power plant.

The solar plant under the scope shall conform to RDSO specification no. RDSO/ PE/SPEC/PS/0092-2008 with
latest amendment and revision at time of approvals. Specific requirement of the project are detailed below, however,
in case of discrepancy in this specification and RDSO specifications, provisions of RDSO specifications shall
prevail.

The items shall be supplied preferably as per RDSO approved list if available. Suppliers approved by MNRE with
sufficient experience of higher capacity installation can also be considered.

The solar array is proposed to be installed over station /service building and if adequate space is not available then
additionally roof of store ward will be used.

The solar PV modules have to be fixed over sheds /buildings in this project. The design of shed and the mounting
structures has to be suitably matched in consultation with OEM for proper installations and ease of maintenance
and repairs. Suitable approach to roof area with ladders shall be provided for inspections and testing. Suitable water
sprinklers for cleaning of surface shall also be installed on roof, if recommended by OEM or site engineer for
periodical cleaning of surface of PV modules.

The space for indoor components PCU and data loggers etc. shall be provided under same shed / nominated
place and AC power shall be fed to nearest LT panel of adequate size.

The OEM and Sub-Vendor for site works shall be prior approved by RVNL and should have executed project of
similar or higher capacity running successfully for at least 3 years at time of approval.
33062: SUPPLY & ERECTION OF PERFORATED CABLE TRAY SIZE 75X75X350MM,
MANUFACTURED WITH 2MM THICK G.I. SHEET ,HOLDING ON G.I. ANGLE 50X50X6MM FOR
SUPPORT AS REQUIRED.
The item price includes Design, Supply, erection, labour & cost of all material including cost of the hot dip
galvanized perforated cable trays and their fittings shall conform to the Indian Standards or their latest amended
editions or equivalent International Standard. Entire work shall be done as per details given in RVNL tech
specifications.
Note: - Payment of suitable GI angle for fixing support will be done under BOQ item no.33022 (iv)
33063(i): FURNITURE SET FOR SUBSTATION

IFB No: RVNL/BSB/GEW/PEP-IAA,MAU-SHG/11

26
03/06/2018
ELECTRICAL GENERAL SERVICES/EXPLANATORY NOTES
Item includes cost of furniture, its transport to the site of use and its installation in the premises as per directions of
the engineer.
Furniture set shall consist of
i) Steel Almirah approx 6'x3'x22" – 1 no.
ii) Staff locker 8 door approx 18"x18"– 1 no.
iii) Table: steel structure approx 5'x3'– 2 no.
iv) Steel chairs - 8 nos.

All furniture shall be of Godrej OR other reputed make as approved by RVNL


33063(ii): LADDER SET
Item includes cost of ladder set, its transport to the site of use and its installation in the premises as per directions
of the engineer.
Aluminium extrusion ladders of following types are included:
i) Simple ladder wide steps 10’2 nos.
ii) Simple extension ladder 24’/44’
iii) Tower Extension ladder 25/45’
Make: PAL EXTRUSION or Similar make as approved by RVNL
33064: SUPPLY AND ERECTION OF ALL TYPES OF GALVANISED STEEL STRUCTURES, SMALL
PARTS STEEL ETC.
The price shall cover cost of erection, alignment and setting before grouting, wherever required, gantries, including
tower / steel tower / bus bar, poles, channels for sub-station, and all other small part steel works, the erection of
which is carried out by the contractor irrespective of whether they are supplied by purchaser/contractor. The prices
shall also include supply and erection of galvanized bolts, nuts washers etc., wherever required as per approved
designs and drawings.

The item price also includes provision of anti climbing devices, and danger plates on the erected structure. The
gantry structure is required, to terminate/extend 11 or 33 KV OH line in sub-station yard. The steel shall be
conforming to IS-2062/1992 (latest) Gr ‘A’ SK zinc conforming to IS-209/1992 or latest.
NOTES :
1. For the purpose of payment against items, weight of structures or fabricated steel work will be calculated
according to the weight of black steel given in section books for the lengths of various members shown in the
approved drawings. There will be no addition for increased weight due to galvanizing or painting or weld material
or reduction for holes or skew cuts.
2. The rates against item shall be applicable to the erection of small part steel work which are not covered under
the various other items of work.
3. The payment shall be made on the basis of the final weight of the structures, in case the same are cut or modified
as indicated above before erection.
33065: SUPPLY AND ERECTION OF 33KV, THREE POLE VCB PANEL
The price shall cover supply installation testing and commissioning of outdoor porcelain clayed type structure
mounted, 33/36 KV3 pole VCB as per IS 13118/IEC56. The vacuum type interrupter is housed inside the hollow
porcelain insulator to form the single phase assemblies each with vacuum interrupter and mounted on a common
base. Terminal conductor shall be suitable for DOG ACSR conductor. VCB shall have spring operated mechanism
common for 3 phases, having spring charging motor enclosed in sheet steel weather proof enclosure with hinged
door and locking arrangement. It shall be provided with spring charge and discharge indication, mechanical
ON/OFF indication,operation counter, emergency hand trip/close arrangement, inspection
IFB No: RVNL/BSB/GEW/PEP-IAA,MAU-SHG/11

27
03/06/2018
ELECTRICAL GENERAL SERVICES/EXPLANATORY NOTES
window,trip/neutral/close breaker control switch, local/remote selector switch (lockable type), set of auxiliary
switch with N/O &N/C contacts. VCB shall be supplied with anti condensation heater with switch & thermostat,
manual operation handle,3pin 5Amp socket with ON/OFF switch, control wiring & labels. The price shall also
include the cost of required nos of supporting insulators with all fixing accessories.

The important specifications are as follows:


Rated voltage - 33/36KV,
Rated frequency -50/60 Hz
Rated current -1250 Amp
Breaking capacity -1560 MVA at 25 kA for 3 sec.
Rated closing current- 63 KA
Rated opening time- 0.06 sec.
Rated closing time -0.1 sec.
Operating duty 0-03 sec —C-0-3min-C-0
Applicable standard IEC pub 56 BS 5311 & JEC -181
Impulse level 170 KA peak
Power frequency for 1 min 70/75 KV
Aux. Supply 110 V DC
The contractor shall submit proto type test certificate of 33kV, VCB along with makers original test certificate
( Make -AREVA /GEC/CGL /Siemens/L&T)

The 33 KV VCB shall include Supply installation testing & commissioning of wound primary oil insulated with
first filling of oil 15 335/83 outdoor type 33KV 50Hz single phase 03 nos CT conf to IS 2705/15:3156/153427,IEC
:185/186/44-1/44-2 with ratio 100-50/5-5A double core class I for metering & class 5p10 for protection , burden
15 VA line voltage 33 kV normal system voltage 33kV highest system voltage 36 KV , impulse level of 170 KV
peak HV pressure test on primary 70 KV IV pressure test on secondary 3KV.
The current transformer shall be housed in sheet steel welded tank suitable for mounting on pre fabricated steel
structure , two nos earthing terminals , drain valve with plug 2 nos lifting lugs and 1 no oil level indicator and other
accessories as required.
It shall also include supply installation testing & commissioning of oil impregnated paper insulated with first
filling of oil IS: outdoor type 33 KV 50Hz single phase 03 nos PT conf to IS:2705/15:3156/1S3427,1EC
:185/186/44-1/44-2 with ratio 33000/V3/110/V3 accuracy class 1,class of insulation A, burden 100VA rated voltage
e factor 1.2 (cont) & 1.5 (30sec) line voltage 33KV, normal system voltage 33KV, highest system voltage 36 KV
impulse level of 170 KV peak for 1.2/50 Micro sec. HV pressure test on primary 70 KV , LV pressure test on
secondary 3KV. The potential transformer shall be housed in sheet steel welded tank suitable for mounting on pre
fabricated steel structures, 2 nos earthing terminals, drain valve with plug, 2 nos lifting lugs and one no oil level
indicator complete and other accessories as required.
(Make AE/BHEL/Mehru/Perfect/L&T/CGL).

33066: SUPPLY AND ERECTION OF CONTROL AND RELAY PANEL FOR 33KV VCB AND 33/11KV
TRANSFORMER
The price shall cover design fabrication, supply, installation, testing& commissioning of indoor type control and
relay Panel board for 33/11KV 3.0/5.0 MVA transformer and 33 KV VCB CT, PT cubical type floor mounted
providing platform for mounting complete with all relays, protective devices, and indicating/measuring devices.
Switching arrangements including supply levelling & connection of control cables of required size as per approved
drawings and relevant IS. It shall also include:
(1) Measuring instrument for voltage current, power factor, energy meter, having MD recording facility of suitable
range.
(2) Indication of status of 33 KV VCB & transformer
IFB No: RVNL/BSB/GEW/PEP-IAA,MAU-SHG/11

28
03/06/2018
ELECTRICAL GENERAL SERVICES/EXPLANATORY NOTES
(3) Tripping indication with the nature of tripping such as Buchholtz relay operation , over current trip, over voltage
trip, earth fault trip, winding temperature trip, oil temperature trip,
(4) Protective relays, Tripping pole over current relays, over voltage relay, under voltage relay, earth fault relay,
winding temperature/oil temperature/Buchholtz relay complete etc. as required.
The above list is not exhaustive and it shall include all accessories required for efficient and reliable operation.
(Make: - AREVA/GEC/CGL/SIEMENS/L&T)

33067: SUPPLY AND ERECTION OF 33 /42KV LIGHTENING ARRESTOR


The price shall cover supply erection testing and commissioning of three piece non linear resister type station class
lightening arrestor on structure (excluding of structure) with surge monitor conforming to IS: 3070(pt-I/1974
suitable for 33 KV (RMS)/42KV (Max) with normal discharge current rating of 10KA and insulating base (1set
consisting of 3nos 33 KV LA) complete with Jumpers, and all accessories etc. as required
(Make-BH EL/Jayshree/AE/CGL/AREVA)

33068: SUPPLY AND ERECTION OF 33 KV, 400A TRIPLE POLE ISOLATOR.


The price shall cover supply ,fabrication ,erection testing & commissioning of 33 KV 50Hz outdoor type triple
pole horizontal mounting 3 insulator type double break central point rotating type air break manually gang operated
insulator having 3 phase 3 nos , per phase 33 KV post type insulator with earthing switch conf to IS : 1818/72 of
the following capacities . complete with handle and key with mounting channel clamps, nuts, bolts, base channel,33
KV post insulator conf to IS: 5350 IEC:168 & BS-3297 fixed contact , moving contact double , terminal pad, arcing
horn connector, phase coupling pipe ,operating down pipe operating box pad lock arrangement. TP locking bolt
clamps basic insulator level 200 KV peak total creepage distance of the insulators not less than 840 mm, phase to
phase spacing of isolator 1500mm, and short time current rating 17.5 kA (RMS) for 3 secs. Complete in all respect
etc. as required.
(Make :- Rastriya electrical & engineering Co/ADCO/MAYUR/JAYSHREE (1) 33 KV GOS 400 ampere
capacity)

33069: SUPPLY AND ERECTION OF 33 KV ACSR BUS BAR.


The price shall cover supply & erection of 33 KV Bus Bar made of ACSR Dog conductor of size A16/4.72mm-
F7/1.57mm conf. to IS: 398/1961 with latest amendment complete in all respect including post insulators and disc
insulators for making 33kv bus on gantry terminal structure in switch yard .The price shall also includes the cost
of , jumper connection with suitable connector, clamps etc as required.

33070: SUPPLY AND ERECTION OF 33/11 KV 3000 KVA TRANSFORMER, MAKE:


ABB/SCHNEIDER/CGL
a) The price shall cover supply at site, erection, testing and commissioning of 33KV / 11 KV (Step Down)
transformer. The transformer shall be ONAN, Oil Cooled or dry type, copper wound with outdoor bushing for
connection with DOG ACSR Busbar on 33 KV side and cable end boxes on 11 KV side for outdoor application.
The transformer shall conform to IS:2026 with latest amendments.
b) Service conditions: The transformer is intended for use in moist tropical climate and in areas subject to heavy
rain and severe lightning in India. The maximum ambient temperature may reach 65°C in the sun with maximum
relative humidity reaching 100%.
c) The design shall incorporate every reasonable precaution for the safety of all those concern in the operation and
maintenance of the transformer.
d) Rating and other particulars:-

The rating and other particulars of the transformers shall be as follows:


i)Type: Core type, double wound, 3 phase, copper wound, Step down for outdoor installation.
ii) System Voltage : 33 KV / 11 KV, 3 Phase
IFB No: RVNL/BSB/GEW/PEP-IAA,MAU-SHG/11

29
03/06/2018
ELECTRICAL GENERAL SERVICES/EXPLANATORY NOTES
iii) Nominal rated secondary Voltage at full load and 0.8 PF : 11 KV 3 phase
iv) Rated frequency : 50 c / s (Hertz)
v) Continuous rating on the Secondary side: 3000 KVA.
vi)Overload Rating : As per IS:
vii) Temperature rise : As per IS:
viii) Impedance Voltage : As per IS:
ix) Tapping capable of handling max. Continuous rated output : Tap (+/-) 2.5%, (+/-) 5%, (+/-) 7.5%, and (+/-) 10%
at any tap setting step .
e) Core and winding:
i) The core shall be built up of Cold Rolled Grain Oriented (CRGO) steel conforming to relevant IS specification.
All laminations used for stacking the core shall be levelled, free from waves, deformation, and rusts. The core shall
be electrically connected to the frame for providing earthing to drain off any electrostatic potential that may be built
up.
ii) The winding shall be so assembled as to be magnetically balanced w.r.t. one another thus resulting minimum
mechanical stresses under short circuit condition.
iii) The copper terminal bars shall be made of electrolytic grade copper as per IS: 1897 —1983.
f) Testing: Testing shall be as per IS: 2026 latest and as detailed in standard specifications.
g) Painting: All steel surfaces which are exposed to weather shall be given two primary coats of Zinc Chromate and
two coats shall be of glossy oil and weather resistant non facing grey coloured paint. This colour shall conform to
relevant BS: 381C (Shade 631)
h) Erection: Installation and commissioning shall include plinth foundation for mounting of transformer, oil
drainage arrangement, painting at site, necessary earthing arrangement, firewall if required. Oil shall be tested for
BDV and filtration shall be done if required before commissioning. This will also include supply erection &
commissioning following instruments
a. 1 no. BDV testing set of approved make.
33071: SUPPLY AND ERECTION OF LED SIGNAGE
The price shall cover supply, erection, testing and commissioning of Acrylonitrile Fibre Translucent type box
signage with MS back, laser cut alphabets, back-lit using OSRAM LED Mono-LED Modules, IP67 protection.
The boxes will be mounted on GI structure with respective angles and columns with required grouting and other
civil works. All operating input drivers will be weather – proof and will be provisioned with auto clock timer for
day- dusk automation, which will be installed in electrical panel box. All cabling and wiring will be done in
accordance to the IP grading and will be wired through PVC pipes. Each LED module power shall be adequate to
have a clear visibility from a distance of at least 3 Km during night time. Gap between LED shall be just adequate
to provide cooling requirement. Power density shall be at least 3 watt per sq. inch of the signage.

33072: SUPPLY AND ERECTION OF LED EDGE LITSIGNAGE


The price shall cover supply, erection, testing and commissioning of LED based designation boards illuminated
from edge and engraved etched names as required on Acrylonitrile fibre board, with two – switch mode of red and
green light colour options for the user and will be provisioned with a hook or screwing system for convenient
installation. The light will be limited only till the extent of the board and will not disturb the surrounding lighting.
Item No.33073:SUPPLY AND ERECTION OF STAY SET
The price shall cover cost of supply and erection of stay set with CC foundation in ratio 1:3:6, stay rod , stay
tightener, stay insulator, GI wire 7/8 SWG, thimble and other fixing accessories as required.
Item No.33074: SUPPLY AND ERECTION OF HYDRAULIC ELEVATED PLATEFORM ON TATA ACE
VEHICLE OF 9.5 M LONG BOOM.
The price shall cover cost of Supply, erection, testing and commissioning of HYDRAULIC ELEVATED
PLATEFORM ON TATA ACE VEHICLE having working height of min 9.5 mtr, outreach of min 3.7 mtrs and
safe working load of min 120kg, slewing range of 360 degree, fibreglass cage of required size to facilitate fixing

IFB No: RVNL/BSB/GEW/PEP-IAA,MAU-SHG/11

30
03/06/2018
ELECTRICAL GENERAL SERVICES/EXPLANATORY NOTES
of fittings and maintenance of electric poles. The system shall be mounted on TATA ACE, HT-BS –IV, chassis
complete with engine, driving cab and all accessories and other details as per specification given as under.

TECHNICAL SPECIFICATION FOR HYDRAULIC ELEVATED PLATEFORM -9.5 MTRS ON TATA


ACE VEHICLE.
The system should be designed and manufactured to the highest quality and safety as per BS standard.
a) All hydraulic system shall be of the fail safe design with lock valves on all rams to protect against hose failure
and also emergency hand pump to enable stowing of hydraulic pump/engine failure. A fibreglass cage insulated to
600V is to be mounted on to a steel cradle with non slip flooring and drain holes for water drainage.
b) PRIME MOVER:- Power required for hydraulic system shall be directly taken from vehicle’s engine.
c) STRUCTURE:- The two articulated booms shall be fabricated of light MS box section. The whole assembly is
mounted on heavy duty slewing rotary joint.
d) HYDRAULIC RAM :- Boom hydraulic cylinders 02 Nos of double acting having precison honed tubes and
induction hardened, deep grounded chrome plated EN-8 piston rods providing smooth operation, long steel life and
resistance against corrosion.
e) STABILIZERS: - Suitable number of hydraulic stabilizers shall be provided with vide footprint to protect the
vehicle from toppling down. Over travel to be provided in the stabilizers to level the vehicle on uneven ground.
The stabilizer shall be fitted with swivel pads.
f) SLEWING: - 360 degree slewing to be provided by hydraulically through worm gear arrangement. Also heavy
duty turntable structure is to be provided with heavy duty roller bearing giving smooth slewing operation.
g) LEVELLING:- Parallel linkage is provided to ensure that the operator’s cage remains level in any boom position
and there is no lost motion.
h) OPERATOR’S CAGE: - A fiber glass cage shall be mounted on to a steel cradle with non slip flooring and drain
holes for water drainage. The cage shall be insulated upto 600 V min.
i) CONTROLS: - Dual control at basket as well as at base shall be provided to hydraulic access elevating platform.
However, stabilizer controls may be provided only at base for safety reasons.
j) EMERGENCY PUMP:- Emergency hand pump shall be provided to enable stopping of the equipment in case of
pump/ engine failure.
k) PERFORMANCE: The system shall have following min performance parameters:
(I) Working height 9.5 Mtrs Approx.
(II) Outer reach 3.7 Mtrs Approx.
(III) Slewing range 360 Degree
(IV) Safe working load 120 Kg.
(V) Safety features:-
(1) Lock valves to boom cylinders to safe guard operators in case of any hose failure/ leakage.
(2) Lock valves of stabilizers to safeguard operator in case of any hose failure / leakage.
(3)Stabilizer to boom interlocks i.e booms cannot be operated unless stabilizers are employed.
(4) Flashers on Drivers cabin.
(5) Emergency Hand pump to enable stowing of equipments in case of hydraulic pump/ engine failure.
(6) Suction strainer to ensure supply of clean oil to the pump.
(7)Pressure relief valve to protect the hydraulic system from overload.
(8) Spot light in the basket.
(9) Safety belt anchorage points on platform.
(10) Emergency stop at base and basket to isolate boom hydraulicfunction.
The complete system shall be similar to HAP-9.5 of Make:- M/s Western Envirotech Pvt Ltd, Ahmedabad or
equivalent as approved by Engineer.
Item No.33075:REFRIDGERATOR, DOUBLE DOOR, FROST FREE MIN 270 Ltr CAPACITY

IFB No: RVNL/BSB/GEW/PEP-IAA,MAU-SHG/11

31
03/06/2018
ELECTRICAL GENERAL SERVICES/EXPLANATORY NOTES
The price shall cover cost of supply and installation of minimum 270 Ltr, refrigerator, double door frost free type,
min 3 star energy rated, suitable to work on 230 Volt AC supply along with electronic voltage stabilizer of suitable
rating for working upto min 170 V voltage.

Non Schedule Items:-

NS-1 Provision of Road Vehicle (Site Facilities)

Supply, installation, testing and commissioning of DG set with acoustic enclosure,


complete with AMF panel and all other accessories and construction of plinth etc.
NS-2 30 kVA DG set with 50 amp, 4-pole ACB (MDO), 50 amps copper bus-bars, 4
pole contactors 63 amp