CSA International - Certified Product Listings
Standards
FW Murphy OK USA 2258-83 PROCESS CONTROL EQUIPMENT- 064764_0_000
Intrinsically Safe and Non-Incendive-Systems-
For Hazardous Locations-Certified to U.S.
Standards
FW Murphy OK USA 3211-07 INDUSTRIAL CONTROL EQUIPMENT- 069293_0_000
Miscellaneous Apparatus
FW Murphy OK USA 3211-06 INDUSTRIAL CONTROL EQUIPMENT-Motor 078646_0_000
Controllers - Miscellaneous
FW Murphy OK USA 3211-86 INDUSTRIAL CONTROL EQUIPMENT-Motor 078646_0_000
Controllers-Miscellaneous-Certified to U.S.
Standards
FW Murphy OK USA 3218-06 INDUSTRIAL CONTROL EQUIPMENT- 078646_0_000
Miscellaneous Apparatus - For Hazardous
Locations
FW Murphy OK USA 3218-86 INDUSTRIAL CONTROL EQUIPMENT- 078646_0_000
Miscellaneous Apparatus-For Hazardous
Locations-Certified to U.S. Standards
Murphy Power Ignition CA USA 2258-02 PROCESS CONTROL EQUIPMENT-For 202340
Hazardous Locations
http://directories.csa-international.org/...rovState=&txtCountry=USA&txtFile=&txtMajorClass=&txtMinorClass=&txtClassDesc=&txtKeyword=[06-Jan-11 13:18:23]
Certification Record
Ignition Controllers, rated 20 to 30V dc, 3A max with the following models:
- MPI-8, MPI-8-SS, MPI-8D, MPI-8D-SS
- MPI-16, MPI-16-SS, MPI-16D, MPI-16D-SS
- MPI-32, MPI-32-SS, MPI-32D, MPI-32D-SS
ITX-230RM Ignition Coil,
- nominal primary voltage 230V (250V max)
- nominal output voltage 27,600V (30,000V max)
ITX-150-12 Integral Ignition Coil, (12 in long)
- nominal primary voltage 150V (200V max)
- nominal output voltage 30,000V (35,000V max)
ITX-150-6 Integral Ignition Coil, (6 in long)
- nominal primary voltage 150V (200V max)
- nominal output voltage 30,00V (35,000V max)
ITX-200RM Shielded Remote Mount Ignition Transformer.
- nominal primary voltage 200V.
- nominal output voltage 44kV.
ITX-170-6, ITX-170-10 and ITX-170-12 Ignition Coils.
- nominal primary voltage 150V dc.
- nominal output voltage 30kV.
ITX -250-12 Ignition Coil
- nominal primary voltage 250V.
- nominal output voltage 42.8kV.
/jj
http://directories.csa-international.org/xml_transform.asp?xml=certxml/202340-2258-02.xml&xsl=xsl/certrec.xsl[06-Jan-11 14:50:18]
Certification Record
Series LM300 oil level maintainers, Models LM301EX through LM305EX. Switch contacts rated 11 amps and 1/3 hp, 125,
250 or 277 VAC; 1/2 amp, 125 VDC; or 1/4 amp, 250 VDC. Enclosure Type 4 rated. Ambient Temperature less than 40C.
Copyright © 2011 CSA International. All rights reserved.
http://directories.csa-international.org/xml_transform.asp?xml=certxml/078646_0_000-3218-86.xml&xsl=xsl/certrec.xsl[06-Jan-11 14:47:51]
Certification Record
Series LM300 oil level maintainers, Models LM301EX through LM305EX. Switch contacts rated 11 amps and 1/3 hp,
125, 250 or 277 VAC; 1/2 amp, 125 VDC; or 1/4 amp, 250 VDC. Enclosure Type 4 rated. Ambient Temperature less
than 40C.
af
Copyright © 2011 CSA International. All rights reserved.
http://directories.csa-international.org/xml_transform.asp?xml=certxml/078646_0_000-3218-06.xml&xsl=xsl/certrec.xsl[06-Jan-11 14:45:54]
Certification Record
Series LM300 oil level maintainers, Models LM301 through LM305 and LM311 through LM315. Switch contacts
rated 11 amps and 1/3 hp, 125, 250 or 277 VAC; 1/2 amp, 125 VDC; or 1/4 amp, 250 VDC. Enclosure Type 4 rated.
Ambient Temperature less than 40C.
af
Copyright © 2011 CSA International. All rights reserved.
http://directories.csa-international.org/xml_transform.asp?xml=certxml/078646_0_000-3211-86.xml&xsl=xsl/certrec.xsl[06-Jan-11 14:43:46]
Certification Record
Series LM300 oil level maintainers, Models LM301 through LM305 and LM311 through LM315. Switch contacts
rated 11 amps and 1/3 hp, 125, 250 or 277 VAC; 1/2 amp, 125 VDC; or 1/4 amp, 250 VDC. Enclosure Type 4 rated.
Ambient Temperature less than 40C.
af
Copyright © 2011 CSA International. All rights reserved.
http://directories.csa-international.org/xml_transform.asp?xml=certxml/078646_0_000-3211-06.xml&xsl=xsl/certrec.xsl[06-Jan-11 14:41:13]
Certification Record
Custom designed engine-generator control panels for surface mounting, wall mounting, or floor mounting each
rated 8A, 24V dc max; 5A, 600V ac max as follows: Models MGCM-86-12 (or -24), MGC-862-12 (or -24),
MGC-861-12 (or -24); Models MGCM-87-12 (or -24), MGC-872-12 (or -24), MGC-871-12 (or -24); Models
MGC-901-12, MGC-901-24, MGC-901-2-12, MGC-901-2-24, MGC-902-12, MGC-902-24, MGC-902-2-12,
MGC-2-24, MGC-903-12, MGC-903-24, MGC-903-2-12 and MGC-902-2-24.
Notes:
1. An additional suffix (-1) may be used to designate a single phase power supply.
2. An additional suffix "DDA" may be added for sales purposes.
http://directories.csa-international.org/xml_transform.asp?xml=certxml/069293_0_000-3211-07.xml&xsl=xsl/certrec.xsl[06-Jan-11 14:39:27]
Certification Record
Note: Panel mounted controller and rail mounted terminal block assembly are for installation in a suitable enclosure.
S1501 Monitor/Control System, consisting of the following equipment, interconnected per installation drawing
50-08-0017:
1. Model S1501PS-120 Power Supply (explosion-proof), input rated 120V ac, 7.5VA 12/24V dc,
3.5W.Contacts rated 5A, 1/16HP 125V ac, 250V ac 5A, 30V dc 30W max; provides intrinsically safe circuits
for Model S1501H Controller.
2. Model S1501H Controller, intrinsically safe and provides I.S. circuits for up to two Model S1500TB32
Sensor Input Switch Terminal Block Assemblies.
3. Up to two Model S1500TB32 Terminal Block Assemblies, intrinsically safe and provides I.S. circuits for
voltage-free contacts.
Note: Panel Mounted Controller and Rail Mounted Terminal Block Assembly are for installation in a suitable
enclosure.
\cc
http://directories.csa-international.org/xml_transform.asp?xml=certxml/064764_0_000-2258-83.xml&xsl=xsl/certrec.xsl[06-Jan-11 14:36:51]
Certification Record
Air/Fuel Ration (AFR) Controller Series. For Control Compliance or FW Murphy, 160W max.
Private Label for Miratech Corporation: MEC Series Controllers, 160W max.
Mark III Selectronic Tattletale control system rated 90 to 250V, CD ignition (Mark III - N version) or 12 to 24V dc (Mark III - 12/24
version) and non-incendive field wiring connections as per Dwg HA14227 and HA14228.
DIGITAL TACHOMETER SHD30, SHD45 or SHD30-45, CD ignition input 90 to 350V dc, magnetic pick-up 5-120V rms, non-
incendive field wiring connections as per Dwg 20-08-0258.
TTDJ Series Digital Fault Annunciator rated 10 to 32V dc (DC Models) or 90 to 350V dc (Capacity Discharge Models)
Millenium Controller, rated 10 to 32V dc, 3A max.
Note: Panel mount equipment. Final installation to be approved by local authorities having jurisdiction.
TTD Series Selectronic, Fault Annunciator (TTD-H, Display Head and PSU-2, Power and Control Inputs/Outputs), rated 10 to 32Vdc.,
5W max.,or Ignition Input 90 to 250Vdc. Max. ambient 85 deg.C. Instal per drawing 50-08-0718.
Note: Equipment is panel mount. Final installation to be approved by Local Authorities having jurisdiction.
TDXM-DC, TDXM-DC-W/SP3LATCH and TDXM-DC-W Temperature Scanners, rated 10 to 32V dc, 500mW.
Note: Certified as component only and Panel mount. Final installation to be approved by local authorities having jurisdiction.
Centurion Controller C3 series rated 10 to 32Vdc consisting of C4-1 or CPC4-1 I/O Module, C3-2, C268, MX4 or MX5 , I/O Expansion
Module and C3-3 Display Module. Depending upon the version of the software in the Display Module, the Display Module can form the
following models: WPC3-3, ESM-D, and MPI-D, C4-3, C3-3S and C4-3S. Models C3-3S and C4-3S are Spanish versions. Max ambient
85°C.
http://directories.csa-international.org/xml_transform.asp?xml=certxml/064764_0_000-2258-82.xml&xsl=xsl/certrec.xsl[06-Jan-11 14:34:47]
WellPro Controller series rated 10 to 32Vdc, consisting of WPC3-1 I/O Module and WPC3-3 Display Module. Max ambient 85°C.
Notes:
1) This device is OPEN type equipment that must be used within a suitable end-use system enclosure, the interior of which is accessible only
through the use of a tool. The suitability of the enclosure is subject to investigation by the local Authority Having Jurisdiction at the time of
installation.
2) Wiring to or from this device, which enters or leaves the system enclosure, must utilize wiring methods suitable for Class I, Division 2
Hazardous Locations, as appropriate for the installation.
3) Panel mount equipment. Final installation to be approved by local authorities having jurisdiction.
• Models M2-G-XX series (Gateway), rated 10-30Vdc, 1.1W max.; M2-DI (Discrete Remote), powered by one 3.6V “AA” Lithium
Battery, 120mW maximum, and M2-TC (Thermal Remote), powered by two 3.6V “AA” Lithium Batteries, 120mW maximum; +85ºC
maximum ambient temperature.
Model code:
M2-G-XX
XX = Firmware revision (any alpha/numeric character - not critical to this certification)
Notes:
These devices are OPEN type equipment that must be used within a suitable end-use system enclosure, the interior of which is accessible only
through the use of a tool. The suitability of the enclosure is subject to investigation by the local Authority having jurisdiction at the time of
installation.
Wiring to or from this device (which includes the installation of the antenna), which enters or leaves the system enclosure, must utilize wiring
methods suitable for Class I, Division 2 Hazardous Locations and environmental certifications on the enclosure, as appropriate for the installation.
Batteries must be replaced by a qualified technician with either Tadiran TL-5903-S or Lisun ER14505.
/dg
http://directories.csa-international.org/xml_transform.asp?xml=certxml/064764_0_000-2258-82.xml&xsl=xsl/certrec.xsl[06-Jan-11 14:34:47]
Certification Record
Class I, Group D:
"Selectronic Tattletale" monitor/control system, consisting of the following equipment, interconnected per
Installation Instructions HC9450-A and HC9450-AA:
Explosion-proof power supply: Model LCDT-PS-CD(R)-P, or LCDT-PS-CD(R)-N, input: 250V ac max
(ignition powered); contacts: 250V ac, 4A; 30V dc, 3A (resistive) or LCDT-PS-120/24/24 input: 120V ac, 6VA;
24V dc, 6VA; 12V dc, 6VA; contacts: 120V ac 30V dc, 4A (resistive). Power supplies provide intrinsically safe
power/control circuits to annunciator.
Annunciator: Model LCDT-NO or LCDT-NC, intrinsically safe.
Terminal Block: Model LCDT-SOTB-NO with Model LCDT-50CA-36 cable assembly or Model LCDT-50TB-
NC.
1. The annunciators and cable and terminal block assemblies are Certified only for use where the suitability of the
installation is to be determined by the local inspection authorities having jurisdiction.
2. Except as connected through Model LCDT-1SB barrier, sensors consist of passive contacts.
3. The power supplies and barrier must be connected to system ground by means of the terminals provided.
Model S1500TB32 terminal block assembly, intrinsically safe and provides I.S. circuits for voltage-free
contacts.
Note: Panel mounted controller and rail mounted terminal block assembly are for installation in a suitable enclosure.
S1501 Monitor/Control System, consisting of the following equipment, interconnected per installation drawing
50-08-0017:
1. Model S1501PS-120 Power Supply (explosion-proof), input rated 120V ac, 7.5VA 12/24V dc,
3.5W.Contacts rated 5A, 1/16HP 125V ac, 250V ac 5A, 30V dc 30W max; provides intrinsically safe circuits
for Model S1501H Controller.
2. Model S1501H Controller, intrinsically safe and provides I.S. circuits for up to two Model S1500TB32
Sensor Input Switch Terminal Block Assemblies.
3. Up to two Model S1500TB32 Terminal Block Assemblies, intrinsically safe and provides I.S. circuits for
voltage-free contacts.
Note: Panel Mounted Controller and Rail Mounted Terminal Block Assembly are for installation in a suitable
enclosure.
http://directories.csa-international.org/xml_transform.asp?xml=certxml/064764_0_000-2258-03.xml&xsl=xsl/certrec.xsl[06-Jan-11 14:31:37]
/cc
http://directories.csa-international.org/xml_transform.asp?xml=certxml/064764_0_000-2258-03.xml&xsl=xsl/certrec.xsl[06-Jan-11 14:31:37]
Certification Record
Air/Fuel Ration (AFR) Controller Series. For Control Compliance or FW Murphy, 160W max.
Private Label for Miratech Corporation: MEC Series Controllers, 160W max.
Notes:
TDX6 Temperature Scanner powered by Certified CD ignition FAIRBANKS 9000, BENDIX S1800 and ALTRONIC I and III or 120V ac.
MDTM89 Dual Temperature Switch gauge powered by Certified CD ignition FAIRBANKS 9000, BENDIX S1800 and ALTRONIC I and
III or 12-24V dc.
MARK IV SELECTRONIC TATTLETALE control system rated 80 to 250V, CD ignition (MARK IV-N version) or 12 to 24V dc/4.7W
(MARK IV-12/24 version) and non-incendive field wiring connections as per Dwg. HC 13439 and HC 13443.
Mark III Selectronic tattletale control system rated 90 to 250V, CD ignition Mark III - N version) or 12 to 24V dc (Mark III - 12/24
version) and non-incendive field wiring connections as per Dwg HA14227 and HA14228.
DIGITAL TACHOMETER SHD30, SHD45 or SHD30-45, CD ignition input 90 to 350V dc, magnetic pick-up 5-120V rms, non-
incendive field wiring connections as per Dwg 20-08-0258.
TTDJ Series Digital Fault Annunciator rated 10 to 32V dc (DC Models) or 90 to 350V dc (Capacity Discharge Models)
Millenium Controller, rated 10 to 32V dc, 3A max.
Note: Panel mount equipment. Final installation to be approved by local authorities having jurisdiction.
TTD Series Selectronic, Fault Annunciator (TTD-H, Display Head and PSU-2, Power Sontrol Inputs/Outputs), rated 10 to 32Vdc.,
5W max.,or Ignition Input 90 to 250Vdc. Max. ambient 85 deg.C. Install per drawing 500-08-0718
http://directories.csa-international.org/xml_transform.asp?xml=certxml/064764_0_000-2258-02.xml&xsl=xsl/certrec.xsl[06-Jan-11 14:28:42]
Note: Equipment is panel mount. Final installation to be approved by Local Authorities having jurisdiction.
TDXM-DC, TDXM-DC-W/SP3LATCH and TDXM-DC-W Temperature Scanners, rated 10 to 32V dc, 500mW.
Note: Certified as component only and Panel mount. Final installation to be approved by local authorities having jurisdiction.
Notes:
1) This device is OPEN type equipment that must be used within a suitable end-use system enclosure, the interior of which is accessible only
through the use of a tool. The suitability of the enclosure is subject to investigation by the local Authority Having Jurisdiction at the time of
installation.
2) Wiring to or from this device, which enters or leaves the system enclosure, must utilize wiring methods suitable for Class I, Division 2
Hazardous Locations, as appropriate for the installation.
3) Panel mount equipment. Final installation to be approved by local authorities having jurisdiction.
• Models M2-G-XX series (Gateway), rated 10-30Vdc, 1.1W max.; M2-DI (Discrete Remote), powered by one 3.6V “AA” Lithium
Battery, 120mW maximum, and M2-TC (Thermal Remote), powered by two 3.6V “AA” Lithium Batteries, 120mW maximum; +85ºC
maximum ambient temperature.
Model code:
M2-G-XX
XX = Firmware revision (any alpha/numeric character - not critical to this certification)
Notes:
These devices are OPEN type equipment that must be used within a suitable end-use system enclosure, the interior of which is accessible only
through the use of a tool. The suitability of the enclosure is subject to investigation by the local Authority having jurisdiction at the time of
installation.
Wiring to or from this device (which includes the installation of the antenna), which enters or leaves the system enclosure, must utilize wiring
methods suitable for Class I, Division 2 Hazardous Locations and environmental certifications on the enclosure, as appropriate for the installation.
Batteries must be replaced by a qualified technician with either Tadiran TL-5903-S or Lisun ER14505.
/dg
http://directories.csa-international.org/xml_transform.asp?xml=certxml/064764_0_000-2258-02.xml&xsl=xsl/certrec.xsl[06-Jan-11 14:28:42]
Certification Record
Junction boxes, Models 65-05-148; with solid cover, with/without hinges; Models 8101-EX and 8102-EX with glass
lens in cover.
http://directories.csa-international.org/xml_transform.asp?xml=certxml/046564_0_000-4418-02.xml&xsl=xsl/certrec.xsl[06-Jan-11 14:26:40]
Certification Record
Vibration- shock detector switch Model VS2EX, 480V ac max. 5A, or VS2EXR rated 24V dc or 120V ac
nominal. Ambient temperature rating: -40ºC to +60ºC
Note: This equipment can be listed under IMI SENSORS as manufacturer name and under Model 685A08.
EVS Series Vibration Switch, rated input 8 to 32V dc/100mA max. Solid State alarm output rated 40Vdc/50mA.
Max ambient 85DegC.
/dg
http://directories.csa-international.org/xml_transform.asp?xml=certxml/046306_0_000-3218-86.xml&xsl=xsl/certrec.xsl[06-Jan-11 14:24:15]
Certification Record
Vibration- shock detector switch Model VS2EX, 480V ac max. 5A, or VS2EXR rated 24V dc or 120V ac
nominal. Ambient temperature rating: -40ºC to +60ºC
Note: This equipment can be listed under IMI SENSORS as manufacturer name and under Model 685A08.
EVS Series Vibration Switch, rated input 8 to 32V dc/100mA max. Solid State alarm output rated 40Vdc/50mA.
Max ambient 85DegC.
/dg
Copyright © 2011 CSA International. All rights reserved.
http://directories.csa-international.org/xml_transform.asp?xml=certxml/046306_0_000-3218-06.xml&xsl=xsl/certrec.xsl[06-Jan-11 13:23:12]
Certification Record
MISCELLANEOUS CONTROLS:
Pressure actuated controls, Series OPL, rated 30V ac, 2A (ind), Series OPLC, rated 125V ac, 125VA pilot duty;
Series 45-PE, rated 250V ac, 1A (ind); 250V ac, 4A; 250V ac, 2A.
Level indicating controls, Series OPL-H and OPL-HA, rated same as OPL Series, Series OPL-HC and OPL-
HACS, rated same as OPLC Series; Series 45-LE rated same as 45-PE Series.
Temperature actuated controls, Series SPL, rated same as OPL Series, Series SPLC, rated same as OPLC Series;
Series 45-TE rated same as 45-PE Series.
Pressure actuated controls, Model OPL-BP, level actuated controls, Model OPL-HA-BP, and temperature
actuated controls, Model SPL-BP, rated 120V ac, 10A, 125VA pilot duty.
Pressure actuated controls, Series OPL-F, rated 30V ac, 2A (ind), Series OPL-FC, rated 125V ac, 125VA pilot
duty; Series 45-PEF, rated 250V ac, 1A; (ind); 250V ac, 4A; 250V ac, 2A.
Level indicating controls, Series OPL-HF and OPL-HAF, rated same as OPL-F Series, Series OPL-HFC and
OPL-HAFCS rated same as OPL-FC Series; Series 45-LEF, rated same as 45-PEF Series.
Temperature actuated controls, Series SPL-F, rated same as OPL-F Series, Series SPL-FC, rated same as OPL-
FC Series; Series 45-TEF rated same as 45-PEF Series.
Level indicating control, Model OPL-HA-FP, rated 125V ac, 125VA pilot duty.
Note: Model number for above controls includes the series number, followed by the gauge range.
Pressure actuated controls, Series 45APE, 45APEF, rated 250V ac, 2A; 6000 cycles.
Level indicating controls, Series 45ALE, 45ALEF, rated 250V ac, 2A; 6000 cycles.
Temperature actuated controls, Series 45ATE, 45ATEF, rated 250V ac, 2A; 6000 cycles.
Notes:
1. Suffix numbers may be used to indicate enclosure mounting, ratings, gauge range and securing element
variations.
2. The controls are Certified for component use only.
/mr
http://directories.csa-international.org/xml_transform.asp?xml=certxml/046305_0_000-4813-02.xml&xsl=xsl/certrec.xsl[06-Jan-11 13:57:01]
Certification Record
MLS Series Liquid Level Switch models: MLS015 and MLS020. Electrical ratings are 30VDC/VAC at 75 mA.
Maximum working pressure is 13.8 MPa (2000 psig). Process temperature range is -29°C to 149°C (-20°F to 300°F).
Ambient temperature range is -29°C to 85°C (-20°F to 185°F). Temperature code T5. Enclosure rated IP66. Single
Seal.
*=Stainless Steel float is standard for LS200 and does not show the SF option.
**= Stainless Steel float is not available on the L1111.
***=Not available with DPDT switch.
# = Not safety critical for this certification.
af
Copyright © 2011 CSA International. All rights reserved.
http://directories.csa-international.org/xml_transform.asp?xml=certxml/046304_0_000-3218-85.xml&xsl=xsl/certrec.xsl[06-Jan-11 13:54:30]
Certification Record
MLS Series Liquid Level Switch models: MLS015 and MLS020. Electrical ratings are 30VDC/VAC at 75 mA.
Maximum working pressure is 13.8 MPa (2000 psig). Process temperature range is -29°C to 149°C (-20°F to 300°F).
Ambient temperature range is -29°C to 85°C (-20°F to 185°F). Temperature code T5. Enclosure rated IP66. Single
Seal.
Float Switches, Model L971, L971-A, thru -G, L972, L972-A thru -G, rated 4A, 250V ac.
af
http://directories.csa-international.org/xml_transform.asp?xml=certxml/046304_0_000-3218-05.xml&xsl=xsl/certrec.xsl[06-Jan-11 13:51:55]
Certification Record
Motor Control Assemblies, 480V ac, max 10A, Cat Nos TR7207, TR7208, TR5171, TR7159, TR9193, TR9194,
TR9195, TR-1760, TR-1761, TR-1762, in general purpose or weatherproof (Encl. 3) enclosures.
"Switchgage" indicating controls: Series A25EO- or A25PE; pressure type, 400 psi and less; Series A25ESR-, or
A25TE temperature type; contact rating 4A, 120V ac.
Notes:
1. Cat Nos may have additional suffix letter to denote variations in construction.
2. "Switchgage" indicating controls may have added suffixes, ES or OS.
http://directories.csa-international.org/xml_transform.asp?xml=certxml/028623_0_000-3211-07.xml&xsl=xsl/certrec.xsl[06-Jan-11 13:47:06]
Certification Record
Time controlled automatic switches, Models 5-TEX, 15-TEX, (minutes) and Models 12-TEX, 24-TEX (hours)
rated 5A, 480V ac, 10A, 250V ac, and 15A, 48V dc.
http://directories.csa-international.org/xml_transform.asp?xml=certxml/027183_0_000-4878-01.xml&xsl=xsl/certrec.xsl[06-Jan-11 13:44:29]
Certification Record
Fuel gas shutoff valves, 5 A max., intermittent duty, Models M-50-81 and M-50-81CD engine ignition powered,
and Model M-50-81B. 12 or 24 V ac or dc, switch contacts rated 5 A, 480 Vac max, maximum working pressure
100 psi (689 kPa).
http://directories.csa-international.org/xml_transform.asp?xml=certxml/021357_0_000-3228-01.xml&xsl=xsl/certrec.xsl[06-Jan-11 13:38:38]
Certification Record
“Switchgage” Pressure Indicating Controls: Series 45APE-EX having contacts rated 250V ac, 2 Amp (Ind), Series
OPLC-EX having contacts rated 125 Vac, 1 Amp pilot duty (6000 cycles) and Series 45PE-EX having contacts rated
250 Vac, 3 Amp (IND, 6000 cycles). Maximum working Pressure 5,000 psi (34.5 MPa).
“Switchgage” Level Indicating Controls: Series 45ALE-EX having contacts rated 250V ac, 2 Amp (Ind), Series
OPLHACS-EX and OPLHC-EX having contacts rated 125 Vac, 1 Amp pilot duty (6000 cycles). Maximum working
Pressure 5,000 psi (34.5 MPa).
“Switchgage” Temperature Indicating Controls: Series 45ATE-EX having contacts rated 250V ac, 2 Amp (Ind), Series
SPLC-EX having contacts rated 125 Vac, 1 Amp pilot duty (6000 cycles) and Series 45TE-EX having contacts rated
250 Vac, 3 Amp (IND, 6000 cycles) .
/ahf
http://directories.csa-international.org/xml_transform.asp?xml=certxml/018709_0_000-3218-85.xml&xsl=xsl/certrec.xsl[06-Jan-11 13:37:14]
Certification Record
“Switchgage” Pressure Indicating Controls: Series 45APE-EX having contacts rated 250V ac, 2 Amp (Ind),
Series OPLC-EX having contacts rated 125 Vac, 1 Amp pilot duty (6000 cycles) and Series 45PE-EX having
contacts rated 250 Vac, 3 Amp (IND, 6000 cycles). Maximum working Pressure 5,000 psi (34.5 MPa).
“Switchgage” Level Indicating Controls: Series 45ALE-EX having contacts rated 250V ac, 2 Amp (Ind), Series
OPLHACS-EX and OPLHC-EX having contacts rated 125 Vac, 1 Amp pilot duty (6000 cycles). Maximum
working Pressure 5,000 psi (34.5 MPa).
“Switchgage” Temperature Indicating Controls: Series 45ATE-EX having contacts rated 250V ac, 2 Amp (Ind),
Series SPLC-EX having contacts rated 125 Vac, 1 Amp pilot duty (6000 cycles) and Series 45TE-EX having
contacts rated 250 Vac, 3 Amp (IND, 6000 cycles).
Pressure switch, stationary, Model DF-755-EX 20 in or less water column, 480V ac and less, 5A.
"Swichgage" Indicating Controls: Pressure switch, Series PT-167-EX, rated 250V ac, 1A (Ind).
"Swichgage" Indicating Controls: Pressure switch, Series 25-EOEX, pressure range 0 to 15 and up to 300 psi.
Rated 4A, 120V, ac. Temperature Switch, series 25-ESREX, temperature range -20 to 450F, rated 4A 120V ac.
"Swichgage" Indicating Controls: Temperature gauge/switch Model SDB-500-EX, temperature range 0 to 500F,
rated 2A 120V ac.
/ahf
http://directories.csa-international.org/xml_transform.asp?xml=certxml/018709_0_000-3218-05.xml&xsl=xsl/certrec.xsl[06-Jan-11 13:26:53]
Certification Record
http://directories.csa-international.org/xml_transform.asp?xml=certxml/018709_0_000-3218-02.xml&xsl=xsl/certrec.xsl[06-Jan-11 14:19:00]
ANNEX B
(November 10, 2003)
Notes:
** - CSA does not have a corresponding category for this UL product category. CSA covers these products under another Class
Number as identified adjacent to the double asterisk ”**”.