PIPELINE CORROSION RISKS ASSOCIATED

WITH A.C. VOLTAGES

AN OVERVIEW

CLEARLY THE BEST


PROTECTION FOR YOUR
INVESTMENT
PIPELINE CORROSION RISKS ASSOCIATED WITH AC VOLTAGES

Introduction

This document discusses corrosion that is believed to be caused by AC current flowing from (i.e.
out of) a buried or submerged pipeline to remote earth via a small coating defect in low resistivity
soil. The most worrying aspect of this form of corrosion is that it occurs at defects that were
previously thought small enough to be left to the Cathodic Protection system to protect, yet the
Cathodic Protection system alone may be insufficient to prevent this type of corrosion. However
once the sections of pipeline that are at risk from AC corrosion have been identified the mitigation
of the risk is relatively straightforward. The current experience, identification of risk and the
mitigation of AC corrosion are discussed in more detail below.

Typical example of AC Corrosion


Corrosion showing Pitting on a Pipeline

Current Industry Experience

There is growing awareness of a type of corrosion on pipelines that cannot be prevented by the
application of conventional Cathodic Protection alone. It is currently believed that this corrosion is
caused by the flow of AC current out of the pipeline at small coating defects and it will be therefore
referred to in this document as AC corrosion.

The most common source of AC current on a pipeline is inductive AC, which is caused by the
interaction between the buried pipeline and the alternating magnetic fields that are generated by
the flow of AC current in overhead power lines. This inductive AC can occur wherever the pipeline
shares a common right of way with one or more overhead power lines. When a buried pipeline
parallels or crosses a high voltage overhead transmission power line (HVTL), the flow of the
alternating current in the power line generates an alternating magnetic field in the air and soil
surrounding the power lines. This alternating magnetic field in turn generates an alternating
current in the pipeline in much the same way as a bicycle dynamo generates current. The
magnitude of the alternating current generated in the pipeline will depend upon an extremely
complex number of factors including soil resistivity, pipeline to power line geometry, coating
condition and power line phase synchronisation.

Some computer software programs and the papers and standards on induced AC are designed to
model or calculate an estimated level of induced AC in terms of its voltage, not the level of AC
current. As discussed later, in the case of AC corrosion, it is the current and more importantly the
current density discharging at the defect that is important in determining if there is a potential AC

CLEARLY THE BEST


PROTECTION FOR YOUR
INVESTMENT
PIPELINE CORROSION RISKS ASSOCIATED WITH AC VOLTAGES

corrosion risk rather than the level of induced AC voltage. All current standards related to the
mitigation of induced AC on a pipeline deal with the safety hazard to personnel and equipment
rather than the risk of AC corrosion. Therefore it is necessary to bear in mind that when the
standards state that the level of induced AC should be kept below 15 Vac this is referring to the safe
level of AC voltage below which there should be no hazard to life or limb if a person were to touch
the pipe (such as CP test point, isolating joint, etc) with induced AC on the line. This limit has nothing
to do with limiting the potential risk of AC corrosion.

Research in Germany, North America and the UK indicates that AC corrosion is very dependent
upon the following factors:

• A source of AC current on the line.


• Small coating defects in the pipeline coating.
• Low soil resistivity at these defects.
• High AC current density at the defects.

As stated above the most common source of AC current on a pipeline is caused by the pipeline
paralleling or crossing an overhead power line, which results in the inductive generation of AC on
the pipeline. Other sources include AC rail traction and possibly the AC ripple generated by the
Transformer Rectifier units of the CP system itself.

The size of the coating defect appears to be very important as well. The exact mechanism of AC
corrosion is not fully understood and more research is required, however it appears that the
optimum size of defect is in the area of 1cm2. lt is possible that this is related to the defect‘s ability
to pass current and the resulting current density being passed. It seems that if the defects are
large the AC current can pass to earth without causing corrosion whilst if the defect is too small
the AC current takes an alternative (lower resistance) route. As with any form of corrosion the
lower the circuit resistance the more corrosion and this is true for AC corrosion. AC corrosion
occurs when the AC current goes to remote earth and it is more likely to do this at defects in
contact with low resistivity soil.

Research indicates that the following current densities appear to be important for AC corrosion:

• 20 A/m2 - Little possibility of corrosion, monitor the situation but no further action required;

• 10O A/m2 - AC corrosion is becoming a possibility, consideration should be given to


mitigation measures.

• 150 A/m2 - AC corrosion is now a distinct possibility, mitigation measures should be put in
place.

lt has been found that AC current densities high enough to cause AC corrosion can occur with AC
voltages as low as 4 Vac and even lower and that the controlling factors are the size of the defect
and the soil resistivity. Therefore as stated above remember that the stated limit of 15 Vac is with
respect to safety issues and not associated with AC corrosion.

CLEARLY THE BEST


PROTECTION FOR YOUR
INVESTMENT
PIPELINE CORROSION RISKS ASSOCIATED WITH AC VOLTAGES

To help explain this better, a number of examples are discussed below:

Imagine a large coating defect in high resistivity soil and that there is a fixed level of AC current
flowing on the pipeline, say 1 A AC. At such a defect the limiting factor to the amount of current
that will flow of the pipeline at this point is the soil resistivity, i.e. the high soil resistivity prevents the
AC current from flowing off the pipeline thereby keeping the current density at the defect low.
Therefore the risk of AC corrosion at such a defect is low.

lmagine the same large coating defect in low resistivity soil with the same 1 A AC flowing on the
pipeline. The large surface area of the coating defect means that even though all of the AC current
flows off the pipeline at this point the current density is still low and therefore the risk of AC
corrosion is low.

Assuming we have the same 1 A AC but that this time the coating defect is small and the soil
resistivity is low then the risk of AC corrosion will be high. This is because the low soil resistivity
represents a low resistance path to remote earth that will be attractive to the AC current and it will
try to leave the pipeline here. When this is combined with a small coating defect, the current
density becomes very high and the risk of AC corrosion is proportionally higher.

Once again if we take the same 1 A AC but this time assume that it is a small coating defect in high
resistivity soil then the limiting factor to the flow of AC current to remote earth will be the soil
resistivity. This means that on a small coating defect the resistance at the interface between the
steel and the soil will be almost infinite thereby limiting the current flow and hence current density
to safe limits.

As discussed above research seems to indicate that there is an optimum size of coating defect,
which will be at risk from AC corrosion. lf the defect is much bigger than this the risk of AC
corrosion is limited because the current density decreases.

Much smaller than this and the AC corrosion risk also decreases probably because the boundary
resistance to remote earth between the bare steel and the soil even through low resistivity soil
approaches infinity and this limits the flow of current to a safe level.

CLEARLY THE BEST


PROTECTION FOR YOUR
INVESTMENT
PIPELINE CORROSION RISKS ASSOCIATED WITH AC VOLTAGES

How do we identify AC Corrosion in the field?

The following procedure has been established;

• Identify those areas of the pipeline where induced AC is likely to occur, i.e. parallelisms or
crossings of HVTL.

• Establish the true level of induced AC in the area(s) of concern. This is done by measuring
the levels of induced AC versus time over a period of time, for example over a minimum of
seven days for twenty-four hours a day. In this way the variation over a typical day during a
typical week can be accurately assessed. There can be significant variations in the levels of
induced AC throughout the day and throughout the week that are caused by variations in
the level of demand placed upon the power grid by electricity consumers. For example
electricity consumption is higher in the evenings when people are cooking and watching
television than at other times of the day. Therefore the load on the power lines is higher and
the induced AC is proportionally increased as well.

Typical Plot Of Induced AC

• The soil resistivity is accurately accessed by using the an appropriate instrument such as a
Geonics EM31 instrument and a datalogger to measure the soil resistivity at 3 and 6
metres depth every 25 metres along the pipeline ROW. The soil resistivity should be
recorded in this way starting from 1,500 metres upstream of the parallelism and finishing
1,500 metres downstream of the parallelism. Experience has shown that AC corrosion can
occur significant distances from overhead parallelisms and this has been explained by the
fact that the AC current will attenuate along the pipeline until it finds a defect in low soil
resistivity where it can discharge to remote earth, thereby causing AC corrosion.

CLEARLY THE BEST


PROTECTION FOR YOUR
INVESTMENT
PIPELINE CORROSION RISKS ASSOCIATED WITH AC VOLTAGES

• Once the levels of induced AC and soil resistivity in the area being surveyed have been
assessed then a DCVG survey should be conducted throughout the same area to identify
and accurately locate the very smallest coating defects, (i.e. those with a % lR of less than 1
% up to a maximum % IR of 3 %). Historically these are the defects that would normally be
left to the CP system to protect and yet are the ones at greatest risk from AC corrosion,
(but only if the soil resistivity is low and the resulting AC discharge current density is
greater than 100 A/m2)

• ln the area considered at risk, small coupons should be installed at every test post at pipe
invert level. The coupons should have a bare area approximately 1cm2 with two test cables,
(one for current measurement the other for potential measurement). The coupon should
be connected to the pipeline via a suitable shunt and the AC current flowing to remote
earth measured across the shunt and directly from a current clamp for comparison. To
avoid excessive excavation costs the coupons can be designed to be augured into place,
(basically a pointed steel coupon on the end of a one and a half metre long T-handle that is
screwed into the soil until it is buried up to the handle).

Typical AC Corrosion Coupon

• Finally if the coupons indicate that the AC current density discharging from the coupons is
in the range of 100 to 150 A/m2 or greater then a selection of the defects identified
during the DCVG survey works should be excavated and inspected visually.

• lf the defects that are excavated for visual inspection show any indication of AC corrosion,
(the visual appearance of AC corrosion is discussed in detail below), then the coating defect
should be repaired and AC mitigation measures designed and put in place. The design of
AC mitigation measures is discussed below.

When inspecting a coating defect that may be or has been at risk from AC corrosion, great care
should be taken to avoid disturbing the soil over the defect. This is because the soil over the site of
AC corrosion is very distinctive.

At sites of AC corrosion the soil forms a hard solid hemispherical cap over the defect. It is thought
that this might be due to heat build up at the defect caused by the passage of AC current into the
soil but there is no hard and fast evidence to support this theory. lf the defect has been attacked by
AC corrosion the corrosion pit will be very spherical and uniform in appearance and approximately

CLEARLY THE BEST


PROTECTION FOR YOUR
INVESTMENT
PIPELINE CORROSION RISKS ASSOCIATED WITH AC VOLTAGES

1 cm2 in area. The coating around the defect may have disbonded from the pipe, normally observed
with FBE coatings, in a spiral fashion almost like the peal of an apple. The corrosion product inside
the defect is just common iron oxides but it is often found to be in the shape of a tree, (i.e. it seems
to form branches of corrosion product from a main trunk growing at the centre of the defect). All of
these are indicative of AC corrosion and are not normally found with other forms of corrosion.

If the above type of defect, soil cap and corrosion product / coating disbondment are found and the
other items discussed above, (such as induced AC and low soil resistivities) are also present at the
defect then it is highly probable that the corrosion is due to AC corrosion rather than anything else.
Once this has been established remedial action is called for.

How is AC corrosion prevented?

Thankfully the mitigation of AC corrosion is relatively simple as it uses the same materials and
techniques as the mitigation of induced AC. If the induced AC and any other sources of AC on the
pipeline can be removed then the pipeline will no longer be at risk from AC corrosion. Having
established that the pipeline is at risk, that there is induced AC and /or other sources and that
there are defects of the correct size to propagate AC corrosion then the following formula can be
used to calculate the minimum level of AC voltage at which AC corrosion will occur:

iac = 8.Vac / ρ.π.d

Where: iac = ac current density (Amps /m2)


Vac = pipe ac voltage to remote earth (Volts AC)
ρ = soil resistivity (Ohm.m)
π = 3.142
d = defect diameter of a circular defect with an area of 1 cm2

Example:

Assuming that we wish to calculate the AC potential required to generate a 100 A/m2 discharge
from a 1 cm2 defect in 10 Ohm.m (1,000 Ohm.cm) resistivity soil we would use the above formula
as follows:

Vac = 100 x 10 x 3.142 x 0.113 / 8


Vac = 4.4 Vac

CLEARLY THE BEST


PROTECTION FOR YOUR
INVESTMENT
PIPELINE CORROSION RISKS ASSOCIATED WITH AC VOLTAGES

Once this minimum voltage has been calculated then suitable AC mitigation measures can be
designed and installed to ensure that the levels of induced AC do not exceed this level. This can
often be significantly lower than the 15 Vac level set for safety reasons. These mitigation measures
can take the form of either zinc ribbon anodes installed in the same trench as the pipeline or bare
copper cable / tape. lf bare copper tape / cable is used then it MUST be connected to the pipeline
via a Cathodic Isolator or similar to prevent it from acting as a current drain on the CP system. If
zinc ribbon is used it is normally connected directly to the pipeline, however if this is done it must be
borne in mind that it will prevent accurate collecting of CIPS and DCVG data from the pipeline. This
is because the zinc will act as an anode during the OFF cycle of the ClPS thereby artificially shifting
the OFF potential in a negative direction and giving a false reading.

Zinc Ribbon Anodes Solid State DC De-


De-coupler

In the case of DCVG survey works the zinc ribbon acts like a huge coating defect preventing the
surveyor from locating the real defects. To avoid this zinc ribbon can be connected to the pipeline
via a Cathodic lsolator or similar. To ensure that the above measures are effective permanent
coupons should be installed along the same section of pipeline where the mitigation measures are
installed. These coupons should have a bare area of approximately 1cm2, two cables and a suitably
rated shunt.

lf the mitigation measures have been successful then the induced AC voltage should be lower than
the level calculated above and more importantly the current density figure for AC current
discharging at the coupons should be significantly less than 100 A/m2. However it should be borne
in mind that the levels of induced AC are time dependant and will vary with the load on the overhead
power lines. Therefore the levels of induced AC and AC current discharge at the coupons should be
recorded for a minimum of seven days for twenty-four hours a day. If the induced AC voltage and
Current density figures stay below the criteria discussed above then the mitigation measures can
be considered to be successful. However they should be monitored routinely throughout the life of
the pipeline to ensure that any changes that might result in the pipeline being at risk again from AC
corrosion are immediately identified and corrected.

CLEARLY THE BEST


PROTECTION FOR YOUR
INVESTMENT
Cathodic 6pp - Single Pages 3/3/08 10:18 Page 6

HEAD OFFICE
Cathodic Protection Co. Limited
Venture Way
Grantham
Lincolnshire
NG31 7XS
United Kingdom
Tel: + 44 (0)1476 590666
Fax: + 44 (0)1476 570605
Email: cpc@cathodic.co.uk
UK BRANCH OFFICE

Cathodic Protection Co. Limited


Electra House
Crewe Business Park
Crewe
Cheshire
CW1 6GL
United Kingdom
Tel: + 44 (0)1270 500440
ABU DHABI OFFICE

Cathodic Protection Co. Limited


Abu Dhabi Branch Office
P.O. Box 52937
Abu Dhabi
United Arab Emirates
Tel: + 971 2 671 6895
Fax: + 971 2 674 2342
Email: cathodic@emirates.net.ae

accreditations

www.cathodic.co.uk

Vous aimerez peut-être aussi