S.

no Column Grid Panel area Loads Staad Loads Ast D/C


1 A4 4.41324 264.79 311.42 690 0.5 7" c/c
2 B1 7.12724 427.63 752.12 690 0.5
3 B2 8.87064 532.24 932.29 690 0.5
4 D2 8.87064 532.24 671.11 690 0.5
5 D4 4.41324 264.79 566.21 690 0.5
6 E1 5.55404 333.24 810.22 690 0.5
7 E2 5.20904 312.54 765.53 690 0.5
8 E3 1.94856 116.91 570.66 690 0.5
3.425
2
1
2
8.425
12.6375
12.5
Area Depths
Grid no. no.s Designation SBC PuMAX MuMAX MyMAX L B Flat Depth D1 Slope Depth Reinforcement
B2,D2 2 F1 200 677.42 4.09 6.11 6' 6' 12" 6" 10@ 6" c/c
B1,E2,D4 3 F2 200 764.58 2.94 6.4 7' 5' 18" 6" 10@5"c/c
E3,A4 2 F3 200 567.98 8.63 25.98 5'6"(1.75m) 5'6" 18" 6" 10@5"c/c
E1 1 F4 200 810.1 12.38 7.77 6' 6' 20" 6" 10@4"c/c
CF1 1 CF1 200 243.54 2.96 0.16 7' 4' 9" 6" 10@6"c/c top and Bottom

Column
Staad Load 1.2 Ast Prov Rf Details
A4 9*12 C1 630 756 1030 4-16,2-12 C6
B1 9*15 717 860.4 1030 4-16,2-12 C1
B2 9*15 872 1046.4 1206 6-16, C2
B3 9*9 144 172.8 678 6-12, C3
C3
C3 9*9 146 175.2 678 6-12, C3
D2 9*15 405 486 1432 6-16,2-12 C5
D4 9*15 1015 1218 1256 4-16,4-12 C4
E1 9*15 C1 647 776.4 1030 4-16,2-12 C1
E2 9*15 458 549.6 678 4-16,2-12 C1
E3 9*15 849 1018.8 1206 6-16, C2
Column
Hand Cal Staad Loads 1.2 Ast Prov Rf Details
A4 9*12 311.42 630 756 1030 4-16,2-12 C6
B1 9*15 752.12 717 860.4 1030 4-16,2-12 C1
B2 9*15 932.29 872 1046.4 1206 6-16, C2
B3 9*9 240.74 144 172.8 678 6-12, C3
C3 9*9 243.54 146 175.2 678 6-12, C3
D2 9*15 671.11 405 486 1432 6-16,2-12 C5
D4 9*15 566.21 1015 1218 1256 4-16,4-12 C4
E1 9*15 810.22 647 776.4 1030 4-16,2-12 C1
E2 9*15 765.53 458 549.6 678 4-16,2-12 C1
E3 9*15 570.66 849 1018.8 1206 6-16, C2