Vous êtes sur la page 1sur 9

PROJECT NO.

PO. 4500098732 / 10 / 01.01.2018


PROJECT TITLE

Supply of PF Process Calculation Spreadsheet (Excel


Forma)
E T
H E
DOCUMENT TITLE

E S
Orifice Sizing Calculation For Liquid Services

P L
as per ISO 5167

M
SA

DATE REV. REASON FOR REVISION PREP. CHKD. APPD. APPD.

DOC. NO. CEPL-PC-001-CA-006 PAGE 1 of 9 REV. 0


Orifice Sizing Calculation For Liquid Services
as per ISO 5167
DOC. NO. CEPL-PC-001-CA-006 REV. 0
PROJECT NO. PO. 4500098732 / 10 / 01.01.2018 PAGE NO. 2 of 9
PROJECT TITLE Supply of PF Process Calculation Spreadsheet (Excel Forma)
BASIS

Calculation Objective

Calculation Basis

E T
Calculation Methodology

H E
E S
PL
M
SA
Assumptions

Software used

Conclusions

References

Attachments
Orifice Sizing Calculation For Liquid Servicesas per ISO 5167
DOC. NO. CEPL-PC-001-CA-006 REV. 0
PROJECT NO. PO. 4500098732 / 10 / 01.01.2018 PAGE NO. 3 of 9
PROJECT TITLE Supply of PF Process Calculation Spreadsheet (Excel Forma)

SCHEMATIC:

qm

P1, T1 P2

The purpose of this workbook is to calculate pressure drop, orifice size or flow calculations for orifices. The workbook can be used only for liquid
phase.

T
Calculation is performed for an Orifice Plate in accordance with ISO 5167-2-2003 edition. ISO 5167-2-2003 is applicable only to a flow which remains
subsonic throughout the measuring section and where the fluid can be considered as single phase. It is not applicable to the measurement of

E
pulsating flow. It does not cover the use of orifice plates in pipe sizes less than 50 mm or more than 1 000 mm, or for pipe Reynolds numbers below

E
5000. The diameter d shall in all cases be greater than or equal to 12,5 mm. The diameter ratio, d/D, shall be always greater than or equal to 0,10 and
less than or equal to 0,75.

ORIFICE TAG NO.

SH
E
LINE NO.

L
P&ID NO.
DESCRIPTION

M P
SA
T 30 oC Operating temperature
P1 9 kg/cm2g Upstream pressure
P2 8 kg/cm2g Downstream pressure

qm 100 m3/h Flow rate


ρ 1000.0 kg/m3 Liquid density
μ 1 cP Liquid viscosity

D 300 mm Pipe ID
Tap type Flange

CALCULATION BASIS / EQUATIONS:


Please refer attachment 1.
Orifice Sizing Calculation For Liquid Servicesas per ISO 5167
DOC. NO. CEPL-PC-001-CA-006 REV. 0
PROJECT NO. PO. 4500098732 / 10 / 01.01.2018 PAGE NO. 4 of 9
PROJECT TITLE Supply of PF Process Calculation Spreadsheet (Excel Forma)

RESULTS:

27.8 Flow rate, kg/s


100.0 Flow rate, m3/h
1000 Liquid density, kg/m3
0.001 Liquid viscosity, Pa.s
30.0 Temperature, oC

T
8.8 Upstream pressure, barg

E
7.8 Downstream pressure, barg

E
98.0665 ∆P, Differential pressure measured across tappings, kPa
14.2196425 ∆P, Differential pressure measured across tappings, psi

H
300 Pipe Inside diameter, mm
117877
0.39
ReD, Reynolds number
m/s, Pipe velocity

E S
L
Flange Tap type

P
0.085 L1
0.085 L'2
0.069 A

M
SA
0.217 M'2
0.2180 β, Beta ratio
0.5980 C, Coefficient of discharge
95.3 ∆w, Overall pressure loss caused by orifice plate, kPa
13.8 ∆w, Overall pressure loss caused by orifice plate, psi
65.41 d, mm, Orifice internal diameter
2.58 d, inch, Orifice internal diameter

CONCLUSIONS:
Orifice Sizing Calculation For Liquid Servicesas per ISO 5167

DOC. NO. CEPL-PC-001-CA-006 REV. 0


PROJECT NO. PO. 4500098732 / 10 / 01.01.2018 PAGE NO. 5 of 9
PROJECT TITLE Supply of PF Process Calculation Spreadsheet (Excel Forma)

ATTACHMENT 1: CALCULATION BASIS / EQUATIONS

E T
H E
E S
PL
M
SA
Orifice Sizing Calculation For Liquid Servicesas per ISO 5167

DOC. NO. CEPL-PC-001-CA-006 REV. 0


PROJECT NO. PO. 4500098732 / 10 / 01.01.2018 PAGE NO. 6 of 9
PROJECT TITLE Supply of PF Process Calculation Spreadsheet (Excel Forma)

E T
H E
E S
PL
M
SA
Orifice Sizing Calculation For Liquid Servicesas per ISO 5167

DOC. NO. CEPL-PC-001-CA-006 REV. 0


PROJECT NO. PO. 4500098732 / 10 / 01.01.2018 PAGE NO. 7 of 9
PROJECT TITLE Supply of PF Process Calculation Spreadsheet (Excel Forma)

E T
H E
E S
PL
M
SA
Orifice Sizing Calculation For Liquid Servicesas per ISO 5167

DOC. NO. CEPL-PC-001-CA-006 REV. 0


PROJECT NO. PO. 4500098732 / 10 / 01.01.2018 PAGE NO. 8 of 9
PROJECT TITLE Supply of PF Process Calculation Spreadsheet (Excel Forma)

E T
H E
E S
PL
M
SA
Orifice Sizing Calculation For Liquid Servicesas per ISO 5167

DOC. NO. CEPL-PC-001-CA-006 REV. 0


PROJECT NO. PO. 4500098732 / 10 / 01.01.2018 PAGE NO. 9 of 9
PROJECT TITLE Supply of PF Process Calculation Spreadsheet (Excel Forma)

E T
H E
E S
PL
M
SA

Vous aimerez peut-être aussi