FLOOR COLUMN

1,3,7,9 2,4,6,8 5 A,B C,D


NO.
P.C.C. 5'6" X 6' A B
FOOTING 5' X 5'6" 5' X 5'6" 4'6" X 4'6" 5'0" X 5'0"
R.C.C. 4'6" X 5' 4'6" X 5' 5' X 5'6" 4'0" X 4'0" 4'6" X 4'6"
STEEL 10MM 6"C/C 10MM 5" C/C 10MM 5" C/C 10MM 7" C/C 10MM 6" C/C 1 3
2
BOTH SIDE BOTH SIDE BOTH SIDE BOTH SIDE BOTH SIDE

D/d 18"/9" 21"/9" 24"/9" 18"/7" 18"/7"


9"x18" 9"x18" 9"x18"
GROUND COLUMN SIZE 9"x9" 9"x9" 4
5
6
FLOOR NO. OF BARS 10-12MM 12-12MM 4-16MM+6-12MM 6-12MM 8-12MM
LEVEL RING 8 MM 6" C/C 8 MM 6" C/C 8 MM 6" C/C 8 MM 6" C/C 8 MM 6" C/C
NO. OF RING DOUBLE DOUBLE DOUBLE DOUBLE DOUBLE 8
7 9
CONC. GRADE M-20 M-20 M-20 M-20 M-20
1,3,7,9 2,4,6,X 5 A,B
COLUMN SIZE 9"x18" 9"x18" 9"x18" 9"x9" C D
FIRST
FLOOR NO. OF BARS 10-12MM 10-12MM 4-16MM+4-12MM 4-12MM
LEVEL RING 8 MM 6" C/C 8 MM 6" C/C 8MM 6" C/C 8 MM 6" C/C
NO. OF RING DOUBLE DOUBLE DOUBLE DOUBLE
CONC. GRADE M-20 M-20 M-20 M-20
SECOND COLUMN SIZE 9"x18" 9"x18" 9"x18" 9"x9"
FLOOR NO. OF BARS 8-12MM 10-12MM 4-16MM+4-12MM 4-12MM
LEVEL RING 8 MM 6" C/C 8 MM 6" C/C 8MM 6" C/C 8 MM 6" C/C
NO. OF RING DOUBLE DOUBLE DOUBLE DOUBLE
CONC. GRADE M-20 M-20 M-20 M-20

BHUPATBHAI
KANPARIYA
12mm - 6 Nos. 12mm - 6 Nos. 12mm - 8 Nos.
12mm - 10 Nos. 12mm - 12 Nos. 16mm - 4 Nos. First Remove
First Remove First Remove First Remove

NOTE :- 5" L SHOULD BE PROVIDED IN FOOTING AND 12" L SHOULD BE PROVIDED IN COLUMN
FOOTING AND COLUMN SIZE FOR EXCAVATION DEPTH UPTO 6' FROM PLINTH BEAM TOP

DESIGN DETAILS OF COLUMN

EXTRA RING 3 nos 12mm


6"

FOOTING DETAILS ECCENTRIC FOOTING DETAILS

NOTE : USE M-20 CON. AND Fe-415 STEEL


15 MM COVER FOR SLAB AND
25 MM COVER FOR BEAM
ALT. BENT Eccentric Ring
50 MM COVER FOR FOOTING
UP

R.C.C. 1:2:3

10 MM 6"c/c
C/C

WAIST SLAB
6" TH.
12 MM 6" c/c

STAIR DETAIL

GENERAL NOTE
1) USE CONCRETE MIXER AND VIBRATOR IN ALL R.C.C. WORK
2) CURING OF R.C.C. SHOUD BE DONE FOR ATLEAST 10 DAYS
3) MASONRY CAN BE DONE BEFORE COLUMN AND SLAB-BEAM
ASSURING NO BULDGE IN FORMWORK AND CAN BE UPTO 4 STOREY BUILDING

4) FOUNDATION DEPTH MUST BE UPTO HARD STRATA


5) STEEL FOR R.C.C. MUST BE OF IS MARK
6) WATER IN CONCRETE AS PER STANDARD WATER RATIO NO EXCESS WATER ALOWED IN CONCRETE

6)ALL DRAWING IS NOT TO SCALE