Vous êtes sur la page 1sur 8

% vol.

distilat temperatura, ᵒC temperatura, K


0 42 315.15
5 54.5 327.65
10 62 335.15
20 73.5 346.65
30 81 354.15
40 87 360.15
50 94.5 367.65
60 102 375.15
70 110 383.15
80 121 394.15
90 134.5 407.65
95 144.5 417.65
100 163 436.15

Densitati si temperatura medie volumetrica


d₄²⁰ 0.721
d₁₅‚₆¹⁵′⁶ 0.7256
API 63.5112
ρL(tco), kg/m³ 677.02112
tm vol (ᵒC) 96.4
tm vol (K) 369.55
Factor de caracterizare
Kw 12.03054
Masa molara (medie)
Mm 99.2969
Raport C/H
Rw C/H 5.37553
Ra C/H 2.21481

Curba VE

% vol. Distilat VE, ᵒC VE, K


0 65.7372 338.8872
10 76.7669 349.9169
30 79.8957 353.0457
50 81.9573 355.1073
70 92.7282 365.8782
90 104.4824 377.6324
100 113.6999 386.8499
TiVE
VE 0% 338.8872 65.7372
VE 10% 349.9169 76.7669
VE 30% 353.0457 79.8957
VE 50% 355.1073 81.9573
VE 70% 365.8782 92.7282
VE 90% 377.6324 104.4824
VE 100% 386.8499 113.6999
Tf₀ 413.5109 140.3609
Tf₁₀ 426.2938 153.1438
Tf₃₀ 429.9077 156.7577
Tf₅₀ 432.2860 159.1360
Tf₇₀ 444.6741 171.5241
Tf₉₀ 458.1214 184.9714
Tf₁₀₀ 468.6146 195.4646
tc1 140.3609
ρL (c0) 677.0211
ρL (c1) 615.1332
ρm 646.0772 Re
μv 0.00787
Vascozitate cinematica
xv 782.8545
Kw*d 8.7293 <10,74
ƲL (tc0) 5.06229E-07
tmc1 105.18
ƲL (tc1) 3.43368E-07
ƲLm 4.24798E-07
3.3. Calculul serpentinei in zona de convectie

Smax 2500

3.2. Alegerea nr. de circuite

C C₂H₄ 27720
Gmp total, kg/h 12000
G total 19200
n circuite 7.68
n circuite 8
Gmp tub, kg/h 1500

3.3.1. Calculul sectorului 1 din zona de convectie

IL, tc0 151.0325


IL, tc1 324.9691
Qf₁c 260904.9507
Lc₁ 15.57
Φtc 60000
de 0.0889
Lu 6
nc₁ 2
di 0.07366
Lech cat 5.52
Lech c₁ 26.62
Ꙍc₀ 0.1444
λ 0.0376
Ꙍc₁ 0.1589
Ꙍmc₁ 0.1517
∆p, Pa 100.985
Gmp, kg/s 0.4167
pc1 6.999
3.3.2. Calculul sectorului 2 din zona de convectie

tc1 140.36
tc2 195.46
tm2 167.91
Iv(tc2),entalpia 743.800
Qf2c 628245.6843
Lc2 37.491
nc2 6.68 7
Lech(c2) 76.16
ρc2 16.49
ρm2 315.8125
Ꙍc2 0.3096
Ꙍm 0.2306
Re 54962.48 41262.16423 Rem
μc2 0.009
Ʋc2 2.74839E-07
∆pc2 52745.2 0.527452
pc2 6.47
Ʋm 3.09103E-07

3.3.3. Calculul sectorului 3 din zona de convectie

tc3=tiR 625
Iv(tc3) 2063.067
Qf3c 1978900.435
Lc3 118.092 0.0889
nc3 21
Lech(c3) 156.764
ρc3 7.78 99.2969 625
ρm3 12.136 16.49
Ꙍc3 5.929 0.4167 16.49 0.07366
Ꙍm 3.119
Ʋc3 1.23624E-07
Ʋm 1.99231E-07
Re 1153224.056
∆p 62012.3 0.620123
pc3 5.85 6.47
μc3 0.01546257

Calculul serpentinei in zona de radiatie

comp mi gfi nfi gi


H2 2.016 0.012 5.952380952 0.0140
CH4 16.043 0.072 4.487938665 0.0837
C2H2 26.038 0.004 0.15362163 0.0047
C2H4 28.054 0.275 9.802523704 0.3198
C2H6 30.07 0.04 1.330229465 0.0465
C3H6 42.081 0.139 3.303153442 0.1616
C3H8 44.097 0.036 0.816382067 0.0419
C4H5 53.084 0.087 1.638911913 0.1012
C4H8 56.108 0.066 1.176302845 0.0767
C4H10 58.123 0.049 0.843039761 0.0570
Mp-bz 99.2969 0.14 1,478 1-k
comb 280 0.08 0.2857143 0.0930
abur 18.1015 0.6 0.03315 0.6977
total 1 1

ns total n 0.0346

Sectorul 1. Zona de radiatie


tr0 625 898.15
tr1 779.05 1052.2
x1 0.25058
Δx 0.25058
Hhc_sp(x,Tr0) 965.12717
Hhc_sp(x,Tr1) 1589.04682
QhcR0 1447690.748
QhcR1 2383570.235
Δi abur 345.08867
QsR1 310579.8001
QfR1 1246459.287
ΦtR 300000
LR1 14.88420
ncR1 2
LechR1 25.93320
pR0 5.85
d₄²⁰comb 1.03
Kw comb 10.29611
ns tot n 0.01622
ns tot 0.02587
Mm0 99.30487
Mm1 61.83735
ρR0 2.05713
ρR1 1.9680 0.081219868
pR1 3.86962
ΔpR1 98181 0.98181 1.98181
ꙌR0 76.08622865
ꙌR1 79.53231287
Ꙍm1 77.80927076
timp st 0.191290802
% vol. Distilat Ai Bi Ci
0 2.9747 0.8466 0.4209
10 1.4459 0.9511 0.1287
30 0.8506 1.0315 0.0817
50 3.2680 0.8274 0.6214
70 8.2873 0.6871 0.9340
90 10.6266 0.6529 1.1025
100 7.9952 0.6949 1.0737
.

27561.84432

Re 27561.84 >2300 regim turbulent


0.07366

ni
0.006921 1
0.005219 2
0.000179 3 0.86
0.011398 4
0.001547 5
0.003841 6
0.000949 7
0.001906 8
0.001368 9
0.000980 10
11
0.000332 12
0.038542 13