Vous êtes sur la page 1sur 12

V/F 0.

5
P (kPa) 18750
Temperatura (K) 310.92

%molar/100 (EXP(Antoine))/P
Componentes % molar Zi Ki
CO2 15.00000 0.15000 2.1157
N2 1.21000 0.01210 3.2082
C1 60.70000 0.60700 1.5138
C2 8.07000 0.08070 0.2631
C3 9.11000 0.09110 0.0685
i-C4 1.22000 0.01220 0.0264
n-C4 2.30000 0.02300 0.0189
i-C5 1.00000 0.01000 0.0075
n-C5 0.84000 0.00840 0.0057
n-C6 0.08000 0.00080 0.0018
i-C6 0.47000 0.00470 0.0025
100.000 1.000

Coeficientes de Antoine
ln(Psat) = A - B / (T + C) donde T está en Kelvin (K)
Componente A B C
CO2 20.57 3103.39 -0.16
N2 12.94 588.72 -6.60
C1 13.21 897.84 -7.16
C2 13.65 1511.42 -17.16
C3 13.71 1872.46 -25.16
i-C4 13.52 2032.73 -33.15
n-C4 13.66 2154.90 -34.42
i-C5 13.62 2348.67 -40.05
n-C5 13.82 2477.07 -39.94
n-C6 13.82 2697.55 -48.78
i-C6 13.73 2614.68 -46.58
DESHIDRATACIÓN CON DESECANTES SÓLIDOS
1- Calculo de W1
Suma Yhc 0.77811 Whc 53
Yco2 0.20371 Wco2 70
W1 () 55.4995833

2- Calculo de la cantidad de agua


Qg 15
DeltaW (lbsH2O/di817.493749
W2 1

Tiempo (t) horas Ciclo W/ciclo (lbs H2O/ciclo)


2 12 68.124479124046
4 6 136.24895824809
6 4 204.3734373721
8 3 272.49791649618
12 2 408.74687474428

3- Determinar capacidad de adsorcion

Adsorbente Silica gel Fig 19.6 Campbell


Tiempo de servici 6
Xdis (lb) 10.5

4- Determinar la cantidad de desecante a usar


Wmaterial/ciclo 1946.41369 lbs material/ciclo
Vmaterial/ciclo 43.2421063 pie3/ciclo
Pb (lbs/pie3) 45.012

5- Determinar área y diámetro del lecho


Qg (pcnd) 15000000
qg (ft3/min) 121.856397
P operacion 1200
Vg (ft/min) 27 Promedio de la figura de la pagina 393 Campbell
A (ft2) 4.5131999
D (ft) 2.39716178
D (ft) corregido 2.5
A (ft2) corregido 4.90873852
Vg (ft/min) correg 24.8243814

6- Determinar altura del lecho


ht (pie/ciclo) 8.80920956
ht (pie/ciclo) corr 9
V(mat/ciclo) corre 44.1786467
W(mat/ciclo) corr 1988.56924

7- Determinar capacidad útil


%RS (asumido) 100
fig 19,7 campXs 16 (lbs H2O ads/100 lbs SG)
fig 19,7 campFactor correcion 0.9
Xs (corregido) 14.4
q (lbm/h*ft2) 7.063146
hz(ft) 7.37758159
X util 10.0979347 (lbs H2O ads/100 lbs SG)

8- Calcular tiempo de ruptura


Ob (h) 5.7916885

9- Calculo de la caida de presion


ht (pie/ciclo) corr 9
fig 23-23 gps viscosidad 0.015
densidad 4.47823719
DeltaP/ht (psi/pie 0.26619099
DeltaP (psi) 2.39571891
0.5
18750 2719.45 psi Tamaño del Contactor
310.92 100 F usando 30" O.D. Gs (MMscfd)
Ct
Zi/(1+0.7*(Ki-1)) Ki*Xi Cg
Xi Yi YI% PM Yi*PM Co (MMscfd)
0.09629 0.20371 20.371428 28.0135 5.70674998
0.00575 0.01845 1.84493155 44.01 0.81195438 Depresión requerida del punto de r
0.48294 0.73106 73.1058055 16.042 11.7276333 Temp pto rocio
0.12778 0.03362 3.36161528 30.069 1.0108041 Fig 14-7 F
0.17051 0.01169 1.1685073 44.096 0.51526498 Entrada 100
0.02377 0.00063 0.06279031 58.122 0.03649498 Salida 40
0.04515 0.00085 0.08527325 58.122 0.04956252 Total 60
0.01985 0.00015 0.01491592 72.149 0.01076169
0.01670 0.00010 0.0095738 72.149 0.0069074 fig. pag 312 Nro de platos
0.00160 0.00000 0.00029098 86.175 0.00025075
0.00938 0.00002 0.00232821 86.175 0.00200633 tabla 3C gravedad especifica TEG
0.9997 1.0003 100.0275 19.8783904 densidad liq

Datos TEG rico


ntoine GE 0.68631371
T está en Kelvin (K) Flujo de gas (MMscfd) 15
C Presión operación (psig) 1200 Reconcentrador
-0.16 Presión maxima cont (psig)
-6.60 Temperatura del gas (F) 100 L (gal/h) 99.375
-7.16 Cont de H2O sale (lb H2O 10
-17.16
-25.16 Criterios de Diseño
-33.15 Relación glicol/agua (gal 3
-34.42 Concen glicol magro (%TEG 99.7 0.997
-40.05 Contactor de bandejas
-39.94
-48.78 Diametro de columna
-46.58 fig 10
A (pulg^2) 30
diametro interno minimo (p 6.2
Componentes Tci (K) Pci (bar) sTc (K) sPc (bar)
Fig 14.7 Campbell CO2 126.2 34 25.7087 6.92629
Fig 20-8/9 GPSA N2 304.2 73.83 5.6123 1.36211
C1 190.6 45.99 139.3397 33.62136
C2 305.3 48.72 10.2630 1.63778
C3 369.8 42.48 4.3211 0.49638
i-C4 408.1 36.48 0.2562 0.02291
n-C4 425.1 37.96 0.3625 0.03237
i-C5 460.35 33.78 0.0687 0.00504
n-C5 469.7 33.7 0.0450 0.00323
n-C6 507.6 30.25 0.0015 0.00009
i-C6 498.15 31.41 0.0116 0.00073
185.9903 44.10828
Tsr (K)
1.67

metodo de Papay Z

DISEÑO DEL REGENERADOR

1- Cálculo del calor total requerido para desorber el agua en el lecho caliente
Ta (F) 100 559.67
Fig 20-80 GPS Trg (promedi 525
Pdiseño 1320
Diametro interior del recipiente t (pulg) 1.09951133
Css 1
Ct 1
Ss () 1572.10336 Cant de silica gel requerido en la zona de Saturación
hz= Lmtz (ft) 0.80014139
ht= Ls (ft) 7.1151308
Peso del acer 6068.96036 lb 10084.3104
Qst (Btu) 309516.978 514299.832
gina 393 Campbell Qw (Btu) 367872.187
Qsi (Btu) 198534.196
Qhl (Btu) 87592.3362 asumiendo que se pierde el 10% 108070.622
Qtr (Btu) 2408789.25 2971942.09

2- Calculo del flujo del regenerador


horas de calentamiento 3
Thot (F) 575 1034.67
Hhot 525
Ha 205
Cp (Btu/lb*F) 0.67368421
mr (lb/h) 2509.15546 3095.77301

3- Verificación de la caida de presion


densidad gas 2.42235206
q 17.2639058 21.3000487
Vg 3.516974 4.33921028
fig 23-23 gpsa Viscosidad 0.02
adimensional B (ctte) 0.056 para 1/8" Bed
adimensional C (ctte) 8.89E-05 para 1/8" Bed
Ec, modi Ergu DeltaP/L 0.00660266 0.00891463

4- Corrección de la velocidad
Vmin 7
Vmin/Vg 1.99034738 1.61319677
mr corregido 4994.09101 4994.09101
q corregido 34.3611696 34.3611696
Ec, modi Ergu DeltaP/L corr 0.01839201
21
1 Resumen de requerimientos
1.008 Contactor de glicol-gas 30" O.D. con 3 platos
21.168 Bombeo de glicol 99,375 gal/h
Caldera 163362,1094 Btu/h
querida del punto de rocío y agua eliminada Stripping Still 6,2 pulg I.D.
Cont de agua
MMscdf
53
8
40

1.111
9.26574

0.9623786 96.2378603

Servicio de la caldera (Reboile duty)


calor requerido
aproximada Qt (Btu/h) 198750
detallado Q(Btu/h) 163362.109
Ql 119250
Qw 27289.6875
Qr 6822.42188
Ql 10000
Psr (bar)
1.87

0.887

lecho caliente
V/F 0.5
P (kPa) 4136.85
Temperatura (K) 200

%molar/100
(EXP(Antoine))/P
Zi/(1+0.7*(Ki-1)) Ki*Xi
Componentes % molar Zi Ki Xi Yi
CO2 15.60000 0.15600 0.0375 0.30071 0.01129
N2 0.10000 0.00100 4.7944 0.00035 0.00165
C1 83.50000 0.83500 1.2532 0.74116 0.92884
C2 0.60000 0.00600 0.0526 0.01140 0.00060
C3 0.10000 0.00100 0.0049 0.00199 0.00001
n-C4 0.10000 0.00100 0.0005 0.00200 0.00000

i-C5
n-C5
n-C6
i-C6
100.000 1.000 1.0576 0.9424

Coeficientes de Antoine
ln(Psat) = A - B / (T + C) donde T está en Kelvin (K)
Componente A B C
CO2 20.57 3103.39 -0.16
N2 12.94 588.72 -6.60
C1 13.21 897.84 -7.16
C2 13.65 1511.42 -17.16
C3 13.71 1872.46 -25.16
i-C4 13.52 2032.73 -33.15
n-C4 13.66 2154.90 -34.42
i-C5 13.62 2348.67 -40.05
n-C5 13.82 2477.07 -39.94
n-C6 13.82 2697.55 -48.78
i-C6 13.86 2911.32 -56.51
55.5 1
60 1.1
65 1.14
70 1.18
75 1.2
80 1.22

Chart Title
1.4

1.2
f(x) = 3.80771E-07 x⁵ − 0.000130603 x⁴ + 0.0178635 x³ − 1.2181
− 561.203
1

0.8

0.6

0.4

0.2

0
50 55 60 65 70 75
Chart Title

0.000130603 x⁴ + 0.0178635 x³ − 1.21812 x² + 41.4255 x

65 70 75 80 85

Vous aimerez peut-être aussi