Vous êtes sur la page 1sur 1

0 1 2 3 4 5 6 7 8 9

LOP
YA Pos. 4.9
EU IAH HS

XHS Event indicator Pos. 4.1 Pos. 4.1.2


TAHH TAH TE greasing system
Pos 4.3.1
Pos. 4.6
Emergency Off
Button Pos. 4.2.1 TS TSH
ECU TS
Pos. 4.2.1.1 M KC

HS HS HS
Pos. 4.2.3.1
M
local / local start / stop TE TAHH
remote YA LS
crusher M
Pos. 4.2.3

local / remote
hydraulic Pos. 4.1.1 Pos. 4.6.1
Pos. 4.6.2
HS YA

TAHH TAH TE TS TSH


Event indicator
(LED pressure ok)

Pos. 4.5 Pos. 4.3.1


HS HS Pos. 4.5.1

hydraulic pump Gap +


SAL SSL ECU TS
on / off
Pos. 4.6.4
HS

Pos. 4.4 Pos. 4.2.3.1


M
Gap -

Pos. 4.2.3

ZIT ZT

EU

Pos. 4.10.1 Pos. 4.10


hydraulic system
Legend
(Generel list, it shows no limits of supply.) Pos. 4.12 M
EU TE TAH TAHH
local in locall control facility
at machine (without PLC) Pos. 4.12.1

Pos. 4.2.1
EU in central control facility Pos. 4.2.1.1
(with PLC/DCS and MCC)

Pos. 4.1: Position number from motor- and component list


SSL SAL YV EU
DCS: Decentral control system
EU: Electrical equipment, drive system control Unit
EH: Electrical Heater / anti-condensation equipment Pos. 4.12.6
ECU: Electrical cooling system, equipment, Pos. 4.4
FS: Flow Switch
IE: Motor Current Element YV EU
IAH: Motor Current Alarm High
HS: Hand Switch
KC: Time Controller PAH PDS
LS: Level Switch Pos. 4.12.7
LAL: Level Alarm Low
LOP: Local Operator Panel (without controller)
M: Engine / Motor / Drive Pos. 4.12.5
MCC: Motor control center TB
PLC: Programmable logic controller LS LAL LALL
PS: Pressure Switch TE TAH TAHH
PAL: Pressure Alarm Low TC EH
PAH: Pressure Alarm High
PDS: Pressure Differential Switch Pos. 4.12.2
PAH: Pressure Alarm High Pos. 4.8 Pos. 4.5
SE: Speed or Frequency Element Pos. 4.5.1
SSL: Speed or Frequency Switch Low Pos. 4.12.8
SAL: Speed or Frequency Alarm Low TB
TE: Temperatur Element
TAH: Temperature Alarm High PAL PS TS TAH TAHH
TAHH: Temperature Alarm High High Pos. 4.12.10
TB: Terminal Box
TC: Temperature Controler
TS: Temperature Switch Pos. 4.12.11
Pos. 4.12.3
TT: Temperature Transmitter
XHS: Emergency Hand Switch
YA: Event, State or Presence Alarm
YV: Electromagnetic valve
ZT: Position Transmitter
ZIT: Position Indicator Transmitter
ZS: Position Switch
The picture is only a sample.
ZAL: Position Switch Alarm Low
A The P&ID diagram is the basis for programming the PLC/DCS system. It shows no limits of supply. Also, a control system is not within Sandvik's scope of
..L = Low (minimum); ..LL = Low Low (empty)
..H = High; ..HH = High High (maximum) supply. For more detailed information about the electrics refer to the motor and components list.

Date 28.02.11 =
SANDVIK MINING AND CONSTRUCTION CR810-08-20_25_30 P&ID Rev.1.vsd Commission: Standardization
Draw Ue +
A 14.05.12 Ue Check
Crushing Technology GmbH P&ID Double roll crusher page 1
Ue Hybrid CR810