IMESA S.p.A.
Via degli Olmi 22
31040 Cessalto (TV), Italia
tel. +39.0421.468011
fax +39.0421.468000
www.imesa.it
E140902X_ENG 24/07/2015
SOMMARIO
SECTION “A” – INTRODUCTION ........................................................................................ 4
1) MANUAL CONTENTS ............................................................................................ 4
2) NORME DI SICUREZZA ........................................................................................ 4
3) MANUFACTURER LIABILITY ................................................................................ 5
4) IM8 MICROPROCESSOR DESCRIPTION ............................................................ 6
3
E140902X_ENG 24/07/2015
1) MANUAL CONTENTS
This manual includes all the information to make a correct service on programmers
mounted on IMESA washing machines.
It includes a first section on the alarmist and its troubleshooting valid for all programmers.
In the second section you can see update procedures and programming related to each
programmer.
This document is written in compliance with the communitarian laws in force and it is
addressed to the service technician, who must be sure to fully understand it, before to
install the kit on the machine.
This instructions must always be available for consultancy. In case it should be lost or
damaged, a new copy must be requested to the manufacturer.
Manufacturer is not responsible for any consequence caused by a not correct kit
installation or caused by the not complete reading of this document or caused by a not
careful reading.
The manufacturer reserves itself the right to modify the here described kit characteristics.
The picture of this documents may defer from reality because of some particular which
could have been changed.
Diagram and technical data may be changed without any notice.
Manual and attachment are part themselves of the installation kit, therefore they must be
stored near the machine and they must follow the machine if it is sold.
2) NORME DI SICUREZZA
Not respecting the following safety rules may cause damages to people, things or animals.
Installation and maintenance of the here described kit must be performed only by
authorized personnel who knows and respect the European rules in matter of industrial
machines installation and service.
The here described washing machines are addressed to the professional washing of linen
and garments: any other use is forbidden, if not authorized in written by the manufacturer.
It is forbidden to wash linen soak in poisons, cancerous products or any other substance
dangerous for the operators health.
Do not approach the machine with inflammable or combustible products to avoid risks of
explosion or burns.
External supplementary connection to the machines release the manufacturer from any
responsibility if the not perfectly performed.
ELECTROCUTION RISK
Any service on machine electric parts must be operated only by qualified personnel
4
E140902X_ENG 24/07/2015
and after that any electrical supply to the machine has been cut.
Power and control circuits can be modified only by manufacturer personnel,
otherwise the warranty would expire immediately.
ATTENTION!
Even if the main switch is in position “0”, cables before it receive tension!
ATTENTION!
These instructions do not cover all possible risks. User must always pay high attention and
respect carefully the rules.
3) MANUFACTURER LIABILITY
The instructions written in this manual are not replacing, but completing the duties deriving
from the safety and accident prevention laws.
With reference to what is written in this manual, the manufacture is not responsible for:
An use of the machine against the safety and accident prevention laws in force.
Not correct machine installation;
Missing of an ordinary and programmed maintenance;
Missing or not respect of the instruction written in the manual;
Tension or supply defects;
Not authorized modification to the machine.
Use of the machine by unauthorized personnel.
5
E140902X_ENG 24/07/2015
It‟s possible to see alarms and troubleshooting directly from www.imesa.it. Click the link
below to see the page referred to the programmer IM8. The same troubleshooting can also
be applied to previous processors IM6 and IM9 timer.
In standard configuration (not self service): press the MENU icon, then the icon
PARAMETERS, enter the password "111111".
In self service configuration: after switching on the machine, at the end of the
software booting, it appears the Italian flag. Press within 30 press within 30 seconds
in the top right corner of the touch screen. It will appear the screen for entering a
password. Then enter the password "111111".
If you can not access by any means that the default password has already been impaired,
contact your support department IMESA SPA for an eventual recovery of the default
password.
2) PARAMETERS
1. LANGUAGES
It allows selection of the language. The vocabularies of different languages must be
present within the SD card of the IM8. The procedure to upload the dictionaries is to use
6
E140902X_ENG 24/07/2015
the menu “PRESET FROM USB” and a USB stick prepared for updating.
The vocabularies of the languages are files ".txt" which contain the various strings that
appear on the display. The ".txt" file must be included inside the USB stick in the path
Preset\IM8_language.
2. DATE - TIME
It allows to adjust the date and time of the system. Date and time are retained in memory
even with the machine off by a buffer battery. If the buffer battery was discharged or
removed, the date and time are reset at each power cycle.
3. DRUM MOVEMENT
In this menu you can define the rhythm of the drum motor, or the timing for the clockwise /
counterclockwise rotation and intermediate pause. The pace of the motor is declared for
each single step of the program and constitutes, together with the rotation speed, of one of
the elements that produces the mechanical action on the laundry.
IM8 contains 16 motor rhythms. The first 12 are already set by IMESA rhythms and
programs are used in standard machine. They are however changeable with the exception
of the first 3 that are used in "EASY PROG". The pace engine 13 and 14 are completely
free. The engine 15 is not as to alter as it is used in a centrifuge. The engine 16 is the
engine "NO" used in delays after the centrifuge and should not be changed.
Below is the summary of the rhythms engine available with their default
parameters.
7
E140902X_ENG 24/07/2015
o FOR STANDARD WASHING MACHINE: the characteristics of the pictures are the
following:
8
E140902X_ENG 24/07/2015
At the end of the copy process you need to restart the washing machine.
5. UPGRADE SOFTWARE
The function allows to upgrade the software. The file that contains the update must be
present inside of a USB pen drive and the file name must be “im8. “ (no file extension).
The file is available in the technical area of the site www.imesa.it. Together with the file
“im8. “ there must be present the Preset folder with its subfolders containing the language,
the images, the blocks ... The update file is available in "zip" format (compressed) with the
name CHIAVETTA COLLAUDO STD.zip. It should be extracted directly to the root
directory of the USB stick, not inside of other folders.
9
E140902X_ENG 24/07/2015
cycles performed by the machine. For more information, see chapter "SERIAL NUMBER".
10
E140902X_ENG 24/07/2015
In standard configuration (not self service): press the MENU icon, then the icon
PARAMETERS, enter the password "111111".
In self service configuration: after switching on the machine, at the end of the
software booting, it appears the Italian flag. Press within 30 press within 30 seconds
in the top right corner of the touch screen. It will appear the screen for entering a
password. Then enter the password "111111".
If you can not access by any means that the default password has already been impaired,
contact your support department IMESA SPA for an eventual recovery of the default
password.
2) PARAMETERS
1. MEASURE UNIT TEMPERATURE
It allows to select the most suitable unit for measuring the temperature. The options are °C
(Celsius) or ° F (Fahrenheit).
Default = °C.
Below is a table comparing the two temperature scales.
°C 0 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90
°F 32.0 50.0 59.0 68.0 77.0 86.0 95.0 104.0 113.0 122.0 131.0 140.0 149.0 158.0 167.0 176.0 185.0 194.0
11
E140902X_ENG 24/07/2015
5. ALARM HISTORY
It is a register that records the last 50 errors that occurred in the machine. The error is
historicized with the date and time when it appeared, also you can appreciate exactly what
stage (STEP) of a given program it took place.
ERROR CODE
The list is not cancellable and is updated automatically. The last error in chronological
order is described in the first row. The 50th error (older) is canceled as a new error is
stored in the first row (newer).
6. ALARM REPORT
Register in which it is indicated the number of times a same error is repeated..
12
E140902X_ENG 24/07/2015
If "WITH HEATING" is selected, the machine activates its own heating system to reach the
set temperature in the program. If the temperature is not achieved within the time
described by the HEATING WDT, the alarm n° 9 "WDT HEATING EXPIRED" will be
generated.
If "HOT WATER" is selected, the machine will not activate its own heating system, but will
use exclusively the hot water supplied from the hydraulic plant in order to reach as close
as possible the required temperature. If the temperature is not reached, the machine will
continue therefore with the wash without giving any errors.
The "HOT WATER" mode bypasses the heating steps present in the programs. Therefore
you will not need to modify the washing program to use of this feature.
Notwithstanding that the spins can be modified both in the duration and in the maximum
speed, the parameter has the only purpose of limiting the maximum speed during the
centrifugation step. It will not be necessary to reprogram the individual spins present in the
programs because they are all subordinate to this parameter.
The level 5 cm is calculated in vertical from the compression chamber. The heating
elements are installed under the compression chamber. The level for enabling the heating
can be reduced up to a minimum of 2 cm, which guarantees the full immersion of the
elements even while the drum is in movement.
13
E140902X_ENG 24/07/2015
The door can‟t be opened until the level falls below the set value.
It is not recommended to increase the default value to prevent overflowing when the
exhaust system was clogged.
You should not change the default value to avoid accidents or delays due to a cooling of
the tank not accomplished.
The parameter has relevance only with machines equipped with autonomous heating (see
"WATER HEATING TYPE").
The value can be modified to introduce any delay in the reactivation of the heating.
Do not set the value to 1 °C otherwise you risk damaging the heating contactor or the
steam inlet valve with sudden and continuous activations.
14
E140902X_ENG 24/07/2015
Automatically the water loading will be stopped at the level set here in this parameter,
even if the programs were configured with higher levels. In the washing programs will only
be possible to set water levels with a value lower than the one set in this parameter. It is
recommended not to set higher values than 15 cm to avoid waste and spills from the
overflow pipe.
a) The machine fills cold water for the time programmed in this parameter.
b) Every 15 seconds the machine checks the temperature and compares it
with the gradient (visible in the step of cooling) and decides whether or not to
activate the valve of the cold water always for the same time set in this parameter.
c) Every minute, the IM8 logic board verify the performance of the
temperature descent, compares it with the gradient set (visible in the step of
cooling), and decides whether to proceed with the cooling or remain on standby (in
case the temperature has drop too quickly).
d) The procedure for loading cold water every 15 seconds, will stop when the
level reaches the maximum value (set in the cooling step). At this point, it proceeds
to the discharge until it reaches the minimum level (set in the cooling step). At its
conclusion the process of loading and control temperature every 15 seconds
restarts.
The programming of this parameter depends on the temperature of the cold water
available to perform cooling, and from the gradient selected in the step of cooling:
The lower the cold water temperature, the lower the activation time of the valve.
The higher is the cold water temperature, the higher is the activation time of the
valve.
The lower the gradient, the lower the activation time of the valve.
The higher the gradient, the higher the activation time of the valve.
16
E140902X_ENG 24/07/2015
o “WDT DOOR CLOSING”: It describes the maximum time allowed to the motorized
door lock for closing the door. (“DOOR CLOSED” contact activatated).
o “ADVANCE AFTER DOOR CLOSING”: It forces the motor of the door lock to
advance further in the closure even after the activation of the contact "DOOR
CLOSED" to ensure airtight seal.
o “WDT ZERO MOTOR”: It describes the maximum time for the door lock to return
back to its initial position (position "ZERO" = activation of contact "ZERO MOTOR").
The door at initial position has to be opened and closed by the operator‟s hand.
o “WDT DOOR OPEN”: It describes the maximum time within the opening of the
door takes place (activation of the contact of "DOOR OPEN").
o “ADVANCE AFTER ZERO MOTOR”: It forces the motor of the door lock to
advance further into the opening even after the activation of the contact "ZERO
MOTOR" (to ensure the effective usability of the opening and closing of the door).
o “DISABLE BEEP”: It allows the activation or deactivation of the buzzer during the
opening and closing process of the motorized door lock.
METEOR 3.0 or
PARAMETRO METEOR 1.0
successive
WDT DOOR CLOSING 25.0 sec 10.0 sec
ADVANCE AFTER DOOR
2.0 sec 3.0 sec
CLOSING
WDT ZERO MOTOR 25.0 sec 10.0 sec
WDT DOOR OPEN 7.0 sec 3.0 sec
ADVANCE AFTER ZERO
0.1 sec (*) 2.0 sec
MOTOR
The main errors associated with the motorized door lock, and its troubleshooting are
described in the document E131203A.pdf.
17
E140902X_ENG 24/07/2015
The “PASSWORD SMS COMAND” allow the consultation via SMS of the washing
machine. You can know the number of cycles performed and the machine status by
sending a SMS to the washing machine. The telephone number of the machine is printed
on the label at the back of the machine:
You can customize this password to prevent other users from querying your machine (up
to 5 digits).
The commands available are just "count" and "status" (washing cycle counter and
machine status).
"MODEM SETUP" is the string that defines the communication protocol used by GSM
modem on your machine. It should not be changed in any way.
18
E140902X_ENG 24/07/2015
(*) NOTE: The inputs Dip.1…Dip.8 have not to be considered for the diagnostic of
the machine. The inputs TANK1…TANK8 can be tested only if the machine is
provided by its own dosing system.
By pressing a single button on the screen, the output (load) is activated until the release.
With this method is possible to verify the activation of the load or control the voltage
applied by using a voltmeter. This utility is valid to check the wiring from the power card to
the device too.
19
E140902X_ENG 24/07/2015
BOARD)
GSM ENABLE THE RESET RELAY FOR THE GSM MODULE
MOTIN ENABLE THE DOOR CLOSING RELAY (ONLY IF THE DOOR PRESENT
INPUT IS ACTIVATED)
MOTAV ENABLE THE DOOR OPENING RELAY (ONLY IF THE DOOR PRESENT
INPUT IS ACTIVATED)
HEAT ENABLE THE HEATING RELAY
DRAIN ENABLE THE DRAIN RELAY
SOAP 1 ENABLE THE WATER SOLENOID FOR THE PREWASH‟S DETERGENT
ST
(WATER PASS THROUGH THE 1 DETERGENT COMPARTMENT)
SOAP 2 ENABLE THE WATER SOLENOID FOR THE WASH‟S DETERGENT (WATER
ND
PASS THROUGH THE 2 DETERGENT COMPARTMENT)
HOT ENABLE THE HOT WATER SOLENOID (WATER DELIVERED DIRECTLY TO
THE DRUM)
COLD ENABLE THE COLD WATER SOLENOID (WATER DELIVERED DIRECTLY TO
THE DRUM)
SOFTNER ABILITA L‟ELETTROVALVOLA DELL‟AMMORBIDENTE
(VASCHETTA DEL DETERSIVO)
PUMPS 1…8 ABILITA LE POMPE PERISTALTICHE (SOLO SE PRESENTE LA SCHEDA
AUSILIARIA PER LA GESTIONE DELLE POMPE)
WARNING!
The “HEAT” button enable the heating! For electric heated washing machines mind
to activate this button just for some seconds to preserve the integrity of the heating
elements.
20
E140902X_ENG 24/07/2015
o “N° OF PROGRAM FOR SELF SERVICE”: It allows to display only a part of the
programs stored in memory. For example, by selecting 5, the machine will only
show the first 5 programs in memory.
Default = 6.
o “STOP BUTTON TIME”: Enable a time which the machine can be stopped and
restarted with another program, without losing the credit.
Default = 0 sec.
The activation of any self service modality is directly related to the parameters “TIME TO
RESET CREDIT” e “MACHINE BUSY”. For more details see the
concerning paragraphs.
o “IMPULSE”: Single action door lock. This setting is valid for LM/RC 8 -11 and for all
the D2W models.
o “MOTORIZED”: Motorized door lock. Correct setting for all the machines with a
21
E140902X_ENG 24/07/2015
higher capacity than 14 Kg (except D2W models). This kind of door lock is
adjustable by setting the “DOOR LOCK MENU” parameters.
“PRESET FROM USB” is used during the software update phase. The data that can be
transferred have to be stored into an USB pen drive with precise paths and subfolders
(see the following diagram).
22
E140902X_ENG 24/07/2015
More information on each single function of the “PRESET FROM USB” menu are
described on the document E120401F and later release, available by request to IMESA‟s
After Sale Dept.
23
E140902X_ENG 24/07/2015
programs (countdown). The remaining time is displayed only during the working phase.
The operation is not going to disrupt the real duration of the program (which depends on
its composition), but only the time left at the end which is displayed on the right part of the
display. For more information on this countdown visualization, visit the chapter "TYPE
COUNT-DOWN".
Default = 60 minutes (for all programs).
As soon as the unbalance microswitch is activated, the spin cycle is stopped for 1 minute
and the drain valve will continue to remain open. During this minute the drum slow down
until stop. After the first minute, the machine starts to load cold water until it reaches the
level of 5 cm. The drum is set in clockwise and counterclockwise rotation at 40 Rpm.
Once the fifth cm is reached the machine will retry the spin sequence.
If the third attempt to spin the microswitch even detects the imbalance, the programmer
will automatically skip to the next block/cycle and will be published to display the error AL8
– TRIPLE UNBALANCE. The machine will continue the remaining washing phases „till the
end of the program.
24
E140902X_ENG 24/07/2015
It is recommended not to alter the default settings on this special cycle that starts
automatically.
p) turn off the machine and let the inverter switches off completelly;
r) evaluate if it‟s necessary to upgrade a new inverter list by using the “PRESET
FROM USB” or just use “SETUP INVERTER FROM SD/IM8_inverter/inverter.txt to
send the listing already stored in the SD to the inverter.
25
E140902X_ENG 24/07/2015
- WATER FEEDING (poor inlet pressure, water leakage at the drain valve, inlet
water filter clogged…);
- RISCALDAMENTO (heating plant not efficient, water leakage at the drain valve,
inlet valves spreading fresh water…) .
Not being able to consider a fixed time for the execution of these processes, the IM8
considers the time limits within which these steps must be completed (WDT).
Automatically all the programs will benefit by the WDT set in this menu, avoiding to adjust
the WDT on each step of WATER FEEDING, DRAIN, HEATING.
26
E140902X_ENG 24/07/2015
(Desired level / “Feeding speed cm/min”) x “Feeding safety coefficient” = (10 / 2.5) x 2.8 = 32’.
All the drains have to be completed within a time of 7' 30 ", regardless of the level you
want to achieve.
If you want to increase the drain WDT, just increase one of two parameters.
(Desired temperature / “Heating speed °C/min”) x “Heating safety coefficient = (78° / 4.5) x 3.0 = 52’
27
E140902X_ENG 24/07/2015
It can be considered that for a precise average are necessary at least ten executions of
the same program. Especially in the first performances of the programs it is possible that
the countdown display “00:00” despite the program has yet to be completed.
The CALCULATED countdown function was created to match the end of a program with
the value 00:00 shown on the display. Before to start a program the IM8 calculates the
sum of all fixed times included in the program (washing time, rinse time, spin time...) and
adds the variable times (the water supply, drainage, heating). The variable times are still
calculated taking in consideration the WDT COEFFICIENTS included in its menu.
At each conclusion of a variable step, IM8 recalculate what is remaining time and
eliminates errors, proposing the new sum. To obtain a time consistent with the duration of
the programs is necessary to set WDT COEFFICIENTS as close as possible to reality.
38. SLOPES
The menu defines the acceleration and deceleration of the basket on three different
frequency ranges. Thanks to the MODBUS communication system between IM8 and the
MITSUBISHI inverter, it is possible to change automatically the value of the parameters P7
and P8 during the operation phase of the machine. The parameters that define the
acceleration and deceleration ramp of of the motor are respectively P7 and P8.
The change of the ramps allows to use three inverter‟s virtual gears. This ensures a
smoother start of the spin and the related slowdown, without overload and without errors
28
E140902X_ENG 24/07/2015
When this parameter is set to "NO" the machine can perform pause/soaking only by
pressing the "PAUSE" button on the touchscreen.
When the parameter is set to "YES" the machine will execute the pauses only by an
29
E140902X_ENG 24/07/2015
external contact closure. The external pause command can be performed also while the
machine is spinning.
NOTE: this parameter enables automatically the parameter " TOUCH SCREEN LOCK
DURING WASHING ", so the machine works with a reduced functionality display. It’s
possible to deactivate the function of the "TOUCH SCREEN LOCK DURING
WASHING", but you can not deactivate a pause/soaking through the keyboard when
the external contact is still closed.
The external contact can be wired directly to the logic board IM8, CN15 connector,
terminals 3 and 4. The contact must be normally open.
The function is of particular interest in the machines with steam heating, where you can
have problems of supply or trouble at the steam generation itself.
When the parameter is set to OFF mode, the machine indicates the expired WDT
HEATING, but continues the program without giving the opportunity to repeat for a second
time the heating step. The machine continues the washing program not reaching the
desired temperature.
30
E140902X_ENG 24/07/2015
The function is particularly dedicated for tilting machine and is proposed as an option on
the official IMESA‟s price list.
The function requires, for safety reasons, the use of both of the user‟s hands. The rotation
is enabled only when the operator presses a backlit button installed on the front of the
machine and at the same time the IM8 touch screen icons for the right or left rotation.
+
42. SERIAL NUMBER
Entering the serial number of the machine in this parameter, enables the creation of a
report at the end of washing cycle, before the opening of the door. The report is a
summary of what the machine did made during the execution of the program. It appears as
follow:
31
E140902X_ENG 24/07/2015
It‟s possible to have a lock to the last report by pressing the new icon which appears on
the lower right corner while the machine is on stand-by and the door is open.
It‟s also possible to see the last report by typing the password “111111” searching for the
parameter “READ LAST REPORT”.
The reports can be downloaded into an USB pen drive. The command “DOWNLOAD
REPORT TO USB/IM8_report” will create a new folder called “IM8_report” on the root
folder of the USB drive.
Inside this folder a “.txt” file will be stored and the name of this file is composed by the
serial number and date of the download.
If you run multiple downloads in one day, the file will be overwritten (in case you are using
the same USB stick).
In the file there are the same indications visible in the display for each wash cycle
accomplished.
Are stored up to 5000 programs, then they will be overwritten in rotation.
32
E140902X_ENG 24/07/2015
NOTE: if the parameter “SERIAL NUMBER” is empty, the reports will not be created
and the folder IM8_report will be empty.
33
E140902X_ENG 24/07/2015
Automatic level = (Real weight of the garments / CAPACITY) x Desired water level
set for the current program;
Automatic soap time = (Real weight of the garments / CAPACITY) x SAP Activation
time
Automatic soap time = (42 / 55)* x 25 = 19** sec.
The default "PROGRAMMING" password is "555555" and is not described in the user
manual of the washing machine to prevent the user can access them. To change the
password, first of all enter the current one and then digit the new one.
If the password is lost, you will need to send back the control card unit to IMESA SPA for
the full reset (custom programs included).
34
E140902X_ENG 24/07/2015
During normal execution of a washing program, on each step is monitored the speed of
the subsequent step. If the speed of the following step is lower than the "SLOWDOWN
THRESHOLD SPEED", the "AUTOMATIC SLOWDOWN TIME" will be inserted
automatically, with the proportion 1:1000 RPM.
The calculation of the automatic slowdown time is the result of this formula:
AUTOMATIC SLOWDOWN = (90 sec / 1000 RPM) x 1000 RPM = 90* sec.
35
E140902X_ENG 24/07/2015
The calculation of the automatic slowdown time is the result of this formula:
AUTOMATIC SLOWDOWN = (90 sec / 388 RPM) x 1000 RPM = 35* sec.
The calculation of the AUTOMATIC SLOWDOWN can‟t be done because the speed of the
step after the spin cycle is higher than the “SLOWDOWN THRESHOLD SPEED” value.
* Parameter "WAITING TIME AFTER THE SPIN" becomes a priority if the "AUTOMATIC
SLOWDOWN” calculated is lower.
o “WATER LEVEL CONTROL”: It defines the level which the water control is
executed. Allowed values 0 to 10 cm. Default = 2 cm..
o “DRUM PAUSE TIME”: It defines the time at which the level is controlled.
Allowed values 0 to 30 sec. Default = 2 sec.
When the function is activated, the machine fills up to the level dictated by the formula:
Level Check Point = Water level set in the program – WATER LEVL CONTROL
36
E140902X_ENG 24/07/2015
When the machine achieve the Level Check Point value it stops for the time described in
the parameter DRUM PAUSE TIME. Then the machine stays idle (no rotation) continuing
to fill water up to the water level set in the current program.
o “MACHINE BUSY WITH”: It is defined the logical state of the relay FREE5,
present on the power card between the contacts 6 and 5 of the connector CN1.
By setting the value to OFF, during operation of the machine the relay remains
switched OFF. By setting the value to ON, during operation of the machine the
relay remains switched ON. The commutation of the relay begin since the
START button is pressed (program start) until the next opening of the door
(conclusion of the cycle).
On self-service machine equipped by central cash payment unit, the value “MACHINE
BUSY WITH” must be turned OFF. Make sure that the central cash payment unit interprets
the “busy” signal delivered by the washing machine with low logic level. This allows you to
retain “BUSY” (not available) a washing machine when it is operating and also when it is
out of service (machine switched off).
On self-service applications with standard coin meter, the value of “MACHINE BUSY
WITH” must be set to ON. This can inhibit the acceptance of coins / tokens when the
machine is in operation (coins / tokens are rejected and expelled by the lower output of the
coin).
WARNING!
The above described settings are standard on self-service systems where COMESTERO®
payment equipment are installed. For any other brand or payment type not tested by
IMESA SPA, refer to the product‟s manual and its distributor.
37
E140902X_ENG 24/07/2015
activated on all machines as it requires the presence of a suitable wiring between the
contactor of the heating elements and the control board IM8.
On machines already provided with this feature as standard, the fire risk alert can be
deactivated anyway.
The function can not be enabled on machines equipped with steam heating or hot water
(self-service).
Default = NO (not active).
When "FIRE PREVENTION" is enabled, the IM8 control unit starts a comparison between
the status of the heating signal applied to the contactor coil and the state of NC contact on
the heating contactor. You can check the following:
HEATING SIGNAL N.C. CONTACT ON
MESSAGE DISPLAYED ON IM8
FROM IM8 HEATING CONTACTOR
HEATING ON OPEN NO ERROR DISPLAYED
HEATING OFF CLOSE NO ERROR DISPLAYED
HEATING ON CLOSE AL30 FIRE PREVENTION NOT OPERATIVE
HEATING OFF OPEN AL29 FIRE RISK ALARM
If "FIRE PREVENTION NOT OPERATIVE" appear, clicking on the screen the machine
goes to the end of cycle. Verify that the heating contactor does not remain mechanically
locked in the rest position (open contacts), or that the heating signal is not delivered to its
coil because of problem at the wiring.
If "AL29 FIRE RISK ALARM - DISCONNECT POWER SUPPLY" appears, you have to
turn off the main switch of the machine (at the back) or unplug the power supply instantly.
Verify the heating contactor is not stuck in the working position (contacts close) when it‟s
not required to heat the water (for example during rinsing, during the spin, or when the
machine is turned off or in stand-by with the door open). Meanwhile, when the alarm is
displayed on the screen, the current cycle is interrupted. The drain valve is commanded to
be close, the drum is idle, then the load of cold water and hot water is forced (valve AF
and AC) until reaching 5 cm level to ensure the immersion of the heating elements. If the
water drops to 3 cm by evaporation or because of leakage at the drain valve, the restoring
of the level is restarted up to 5 cm. The process of immersion of the heating elements
continues until the shutdown of the machine.
38
E140902X_ENG 24/07/2015
WARNING!
For machines not equipped with “fire prevention” harness, if this parameter was activated
accidentally, it will still be published on the display the alarm "AL29 FIRE RISK -
DISCONNECT POWER SUPPLY". Turn off the machine, wait for the reappearance of the
alarm, press 5 times in the center of the display, then one time the lowest left corner,
then one time the lowest right corner too. The IM8 will allow access to the parameter
“FIRE PREVENTION” to disable it by placing it on "NO". Press "OK", turn off and on the
machine.
39