For combination with RHE07, 08, 11, 12, 14, 16 transmitter please refer to tab 'RHM-RHE07-16'
Temperature Range
#### N1 NT Standard from -20 to +120°C (standard) N1
#### NA ET Extended from -45 to +120°C
#### E2 ET2 Extended from -45 to +210°C
#### E3 ET1 Extended from -196 to +50°C (2)
#### H4 HT High from 0 to 350°C
Pressure Range of Measurement Loops - refers to standard Material 1.4571 (316Ti) at 120°C
#### P1 Measuring Loops max. 93 bar - max CL 600 / PN 40 P1
(4)
#### P2 Measuring Loops max. 184 bar
Construction Type
#### PF0 Parallel Measuring Loops Seal Less Version PF0
Process Connection
#### C1 Flange DIN DN100/PN40 Form C F3
#### C2 Flange DIN DN100/PN100 Form E
#### F1 Flange ANSI 4" 150# RF/SF
#### F2 Flange ANSI 4" 300# RF/SF
#### F3 Flange ANSI 4'' 600# RF/SF (11)
#### R0 Flange ANSI 4" 900# RTJ
PED compliance according to module A2 (10) - suitable for all sensors if flow does not represent an
#### A2
unstable gas, see list in tab 'Unstable Gases'
#### BC PED compliance according to module B3.2+C2 (10) - required if A2 does not apply
#### CA CRN compliance - Alberta Province Only (13)
#### CR CRN compliance - All Provinces except Alberta (13)
Performance Certification
#### N No Performance Certification N
LOW FLOW CALIBRATION (SELECTED SENSOR) (9) - 0.2% uncertainty between 2000 and 100 kg/min,
#### 2
0.5% between 100 and 60 kg/min, 0.6% between 60 and 45 kg/min
#### G GOLDLINE (SELECTED SENSOR) (9) - 0.15% uncertainty between 1800 and 180 kg/min
Density Calibration
#### N No measured density. Volume indication is possible via FixDens function of RHE N
(6)
#### S Standard Calibration 1% Uncertainty
#### D Enhanced Calibration 0.50% Uncertainty (6)
Manufacturing Instructions
#### N No manufacturing instructions N
#### O Special Cleaning, fat free
#### S Sea-worthy packing
For more options please look up 'General Options' Tab / Price Sheet
(2)
Option E3 is only applicable for material SS 1.4571 (316Ti). Housing purges (Option P2) are mandatory
(4)
Heavy Wall Thickness like P2 will reduce up calibration range limits and increase DP.
(5)
Heating systems suitable for thermal oil and vapor max 20 bar, 350°C.
(6) Density statements refer to standard sensors (temperature, material) and water at reference conditions and require
respective RHE transmitter capability
(7)
Each calibration comprehends at least 5 calibration points.
Please add 350 Euro on the price for each additional calibration point.
(8)
If separately ordered and / or for the witnessing of the sensor, please consider 2500 EUR.
(9)
Selected sensors are only available in combination with temperature option T1, TA,
standard material and pressure range.
(10)
Upon request Rheonik issues a respective certification according PED, please see Documentation tab.
(11)
Flange reduces the maximum allowable pipe pressure by a factor of 0.73.
(12)
Highest calibration point in factory is at 2200 kg/min (Flow Calibration A) and 2000 kg/min (Flow Calibration B).
Stated uncertainty is warranted up to 2500 kg/min.
(13)
Stated pmax values of Pressure Range (measuring tubes) and Construction Type may differ according CRN.
For Alberta Province special compact flanges are required. Please consult factory for details.
Please remind: this is not a configurator / invalid combinations are possible / weakest part decides pmax of sensor