Vous êtes sur la page 1sur 2

909X GYRO DRIFT PROCEDURE

After calibration of the 909X Gyro Logging Tool, and on a monthly basis, the drift of the gyro should
be tested on the deviation test stand. The procedure is as follows. Record the results on the bottom
of the test sheet below.

1. Tool Warm-up. Allow the tool to spin-up for at least one hour before testing. In extreme cold
conditions, an additional ½-hour spin-up time should be used.

2. Use normal logging procedures using the time-drive function in LOG. As we like to talk about
drift per hour, the log recorded should be 600 feet at 10 feet per minute rate

3. The test stand direction is set to north, with the dimple facing also facing north; you need to
enter the toolface direction of 0 degrees, and magnetic declination of 0, prior to starting the log.
Remember to change the logging direction to UP.

4. Prior to starting the logging, Cage and then Uncage the Gyro.

5. Also, mark a reference spot on the tool to indicate toolface direction, to stop the tool at precisely
the same spot on the tool. This would be similar to sighting to a survey stake at the beginning
and end of a survey.

6. Begin logging, allow the depth to change to 500 feet.

7. Rotate the tool four (4) revolutions in one direction.

8. After four (4) revolutions, stop the rotation and continue logging for 150 feet.

9. Rotate the tool in the other direction four (4) revolutions. Make sure to stop the tool at the
marked spot. (NOTE: Some rotational motors will work in only one direction).

10. Continue logging until the entire hour test is complete.

11. Record the indicated data below, from gyro QC log.

909X Tool Number ___________________ Gyro Serial Number ________________


Date of Test ________________________ Office Location ____________________
Test Stand Angle ____________________ Performed By _____________________

Initial Sangb ________ Calculated Drift/Hr.

Sangb Before 4 Revolutions ________ Diff. from Last Reading _____ _________

Sangb After 4 Revolutions ________ Diff. from Last Reading _____ _________

Sangb Before 4 Revolutions ________ Diff. from Last Reading _____ _________

Sangb After 4 Revolutions ________ Diff. from Last Reading _____ _________

Sangb at End of Logging ________ Diff. from Initial Sangb _____ _________
(Sighted Drift rate per hour)
Gyro Performance Evaluation

1. Drift during rotational periods less than 25 degrees per hour. _________
2. Drift during stationary periods less than 10 degrees per hour. _________

3. Sighted drift over the approximate 1-hour test should be less than 15 degrees. _________

Inclinometer Performance Evaluation

1. Slant Angle should not deviate outside the test stand angle +/- 0.5 degrees. _________

2. Slant Angle should not vary more than 0.25 degrees during any stationary period. _________