Vous êtes sur la page 1sur 44

Using the

Ducted Gas Central Heating


Add-on Refrigerated Air Conditioning
Ducted Evaporative Air Conditioning

with your

multi-appliance
Manual Control

Owner’s Manual

Please keep this important manual in a safe place. It is the owner’s responsibility to ensure that
regular maintenance is carried out on this ducted heating / cooling product. Failure to do so will
void all guarantees beyond statutory and legal requirements.
www.climatetechnologies.com.au

PNE2003 Series Control


Multi-Appliance Manual Control

Contents
Contents

INTRODUCTION...................................................................................................5
YOUR MANUAL CONTROLLER .................................................................................................................5
GENERAL INFORMATION..........................................................................................................................6
Important Installation Notice. .................................................................................................... 6
Data Location............................................................................................................................ 6
Warranty ................................................................................................................................... 6
Assembly. ................................................................................................................................. 6

Navigating the Controls......................................................................................7


QUICK START - SIMPLE MANUAL OPERATION.......................................................................................8
CONTROL FUNCTIONS..............................................................................................................................9
ON / OFF .................................................................................................................................. 9
MODE ....................................................................................................................................... 9
Icons........................................................................................................................................ 10
Child Lock ............................................................................................................................... 10
Reset....................................................................................................................................... 11
CLOCK Setup ......................................................................................................................... 11
Fault Codes............................................................................................................................. 11

Ducted Gas Central Heating.............................................................................12


SAFETY ..................................................................................................................................................... 13
Safety & Owner Responsibility ............................................................................................... 13
Precautions. ............................................................................................................................ 13
Features.................................................................................................................................. 13
Power or Gas interruption....................................................................................................... 13
USING YOUR MANUAL CONTROL WITH DUCTED GAS CENTRAL HEATING..................................... 14
Heating Operation................................................................................................................... 14
Summer Fan (Fan Only) ......................................................................................................... 15
Summer Shutdown (Optional) ............................................................................................... 16
First Startup Or Restart After Shutdown ................................................................................. 16
HEATER MAINTENANCE ......................................................................................................................... 17
General Maintenance.............................................................................................................. 17
Scheduled Maintenance ......................................................................................................... 17
PROBLEM SOLVING................................................................................................................................. 18

ADD-ON Refrigerated Air Conditioning...........................................................19


GENERAL INFORMATION........................................................................................................................ 20
Important Notice...................................................................................................................... 20
Data Location.......................................................................................................................... 20
Assembly. ............................................................................................................................... 20

Bonaire Control Systems Page 2


Multi-Appliance Manual Control

Contents
Contents

SAFETY ..................................................................................................................................................... 20
Safety & Owner Responsibility ............................................................................................... 20
Precautions. ............................................................................................................................ 20
Features.................................................................................................................................. 20
Power interruption................................................................................................................... 20
USING YOUR CONTROL WITH DUAL CYCLE AIR CONDITIONING...................................................... 21
Operation ................................................................................................................................ 21
Fan Operation ......................................................................................................................... 22

Ducted Evaporative Air Conditioning..............................................................23


INTRODUCTION........................................................................................................................................ 24
Air Relief ................................................................................................................................. 24
Dialflo ...................................................................................................................................... 25
Optional Dump Valve .............................................................................................................. 25
OPERATING THE MANUAL CONTROL. .................................................................................................. 26
COOL Mode............................................................................................................................ 26
COOL FRESH AIR Mode........................................................................................................ 26
FRESH AIR Mode................................................................................................................... 27
DUCTED EVAPORATIVE AIR CONDITIONER MAINTENANCE.............................................................. 28
General. .................................................................................................................................. 28
Filter Pads............................................................................................................................... 28
Water Tank ............................................................................................................................. 28
Water Level / Float Valve........................................................................................................ 28
Motor and Fan......................................................................................................................... 29
Electrical ................................................................................................................................. 29
Bleed Off ................................................................................................................................. 29
Pump....................................................................................................................................... 29
Water Distribution ................................................................................................................... 29
No Seasonal Maintenance...................................................................................................... 29
TROUBLE SHOOTING GUIDE.................................................................................................................. 30

Control setup.....................................................................................................31
SETTING UP THE CONTROL - GENERAL............................................................................................... 31
Before Starting ........................................................................................................................ 31
Installation............................................................................................................................... 31
USING THE SETUP MODES .................................................................................................................... 32
Product Identification .............................................................................................................. 32
CODING..................................................................................................................................................... 32
Auto-Coding ............................................................................................................................ 32

Bonaire Control Systems Page 3


Multi-Appliance Manual Control

Contents
Contents

Manual Coding........................................................................................................................ 32
Important Notes ...................................................................................................................... 33
Calibrating the Thermostat. .................................................................................................... 33
Fault Codes Access ................................................................................................................ 33
View The Fault Codes............................................................................................................. 33
EVAPORATIVE AIR CONDITIONING SETUP .......................................................................................... 34
Setting the Fan Speed ............................................................................................................ 34
DUCTED GAS CENTRAL HEATING......................................................................................................... 35
Setting the Fan Speed ............................................................................................................ 35
COMMISSIONING CHECK LIST ............................................................................................................... 36
General ................................................................................................................................... 36
Unit - Ducted Evaporative Air Conditioner .............................................................................. 36
Unit – Ducted Heating............................................................................................................. 36
Unit – Dual Cycle Refrigerated Air Conditioning..................................................................... 37
Ductwork ................................................................................................................................. 37
Site .......................................................................................................................................... 37
Customer Hand Over .............................................................................................................. 37

Warranty.............................................................................................................38
SERVICE ............................................................................................................42

Bonaire Control Systems Page 4


Multi-Appliance Manual Control

Introduction
Introduction
INTRODUCTION

YOUR MANUAL CONTROLLER


This technologically advanced controller comes with manual controls for cooling and thermostat
controls for heating plus many other setup functions.
Your Manual Control has been designed to operate the following products:

Heating – 3, 4, 5 Star Ducted Gas Central Heaters.

Dual Cycle Cooling - Refrigerated Air Conditioning (cooling only) designed to Dual Cycle to
Ducted Gas Central Heaters.

Fresh Air Conditioners - Ducted Evaporative Air Conditioners.

Bonaire Control Systems Page 5


Multi-Appliance Manual Control

Introduction
Introduction

GENERAL INFORMATION.
IMPORTANT INSTALLATION NOTICE.
A licensed person is required to install Climate Technologies equipment. If the equipment is not
installed in a accordance with the installation instructions and the governing body regulations,
Climate Technologies reserves the right to refuse service on non compliant installations.

Subject to state regulations and by laws a certificate of compliance must be issued for the
electrical and plumbing connections certifying that the work complies with all the relevant
standards.

Note: Only a licensed person will have insurance protecting their workmanship.

DATA LOCATION.
Your appliance model number, serial number and model description are located on the appliance
data plate on the end of the heater or inside the cooler in the vicinity of the electronic controls.
These details should also be in the warranty section of this booklet.

You will need this information, should your appliance require servicing, spare parts or just if you
require additional information about this product.

WARRANTY
Warranty service work must only be carried out by Climate Technologies service division or its
authorised service providers. See warranty section.

ASSEMBLY.
There is no assembly required of these Ducted Heating or Cooling products. Your Dealer or
installer will carry out all assembly and commissioning upon installation.

Bonaire Control Systems Page 6


Multi-Appliance Manual Control

Navigatingthe
Navigating theControls
Controls

Navigating the Controls

Number Description Function

1 SCREEN DISPLAY Displays unit functions selected

2 ON / OFF Turns the unit ON or OFF

3 MODE Pressing the MODE button cycles you through the


available unit operation options.

4 UP Pressing the UP button increases the fan or


temperature setting.

5 DOWN Pressing the DOWN button decreases the fan or


temperature settings.

Bonaire Control Systems Page 7


Multi-Appliance Manual Control

Navigating the Controls

QUICK START - SIMPLE MANUAL OPERATION


Here's all you have to do to get going (if the installer
hasn't already done it for you). Your manual thermostat
is designed to give you simple operation control over
your product. Any changes made to the control settings
will have a 3 second delay before the unit responds.

STEP 1 Turn the control ON at the ON / OFF


button.

STEP 2 Subject to the product(s) installed,


select the mode of operation by
pressing MODE button to select HEAT,
COOL, FRESH AIR or COOL FRESH
AIR.

STEP 3 Adjust the fan speed or the temperature


setting using the UP DOWN buttons.

(The icon(s) availability will vary


according to the Appliances selected.)

STEP 4 Press the ON / OFF icon to turn unit off.

Bonaire Control Systems Page 8


Multi-Appliance Manual Control

Navigating the Controls

CONTROL FUNCTIONS
ON / OFF
When pressing the ON / OFF button to turn the unit
on, the manual control will return to the last used
setting.

When unit is turned on the last used appliance will


be activated. This control is capable of controlling
the following Climate Technology Products
installed with PNE control systems:

• Ducted Gas Central Heating


Number Description
• Dual Cycle Ducted Gas Central Heating and 1 Mode Functions
Dual Cycle Refrigerated Air Conditioning
2 12 Hour Clock
• Ducted Evaporative Air Conditioning
3 ON / OFF

• Ducted Gas Heating and Ducted Evaporative 4 Function Symbols


Air Conditioning
5 Temperature
MODE
Press the MODE button to cycle through the available mode options. Only the modes relative
to the unit installed will be displayed.

• COOL – (Evaporative Air Conditioning) Pump Only. This function will allow you to
manually pre wet the filter pads by running the pump only.

• FRESH AIR - Fan only (Evaporative AC). This means the fan only can be run and the
fan speed adjusted via the UP / DOWN buttons.

• COOL FRESH AIR – The fan and pump will operate together with an evaporative air
conditioner.

• HEAT - Thermostat will control the unit via a temperature sensor. The comfort level can
be adjusted using the UP / DOWN buttons to increase or decrease the SET TEMP
amount of heating required.

• Fan Only (Heating Mode) – Only the fan symbol and the bar scale will be activated during
fan only mode. This allows the fan to operate without any heating functions.

• COOL – (Dual Cycle Refrigeration) Thermostat will control the unit via the temperature
sensor. The comfort level can be adjusted using the UP / DOWN buttons to increase or
decrease SET TEMP. The fan will run while the condenser cycles on and off.

• Continuous fan – (COOL Dual Cycle Refrigeration) The fan symbol will be displayed in
addition to the COOL and snow flake indicating the fan will run continuously while the
condenser cycles on and off.

Bonaire Control Systems Page 9


Multi-Appliance Manual Control

Navigating the Controls

ICONS
The operating icons will be displayed relative to the
installed product.

1. Bars Indicator evaporative cooling fan speed.

2. Water Droplets indicate the evaporative cooler


pump is on.

3. Fan indicates the evaporative cooler or central


heater unit fan is operating.

4. Flame indicates that the thermostat is calling for


heat from the ducted central heater

5. Snow Flake indicates the Dual Cycle refrigerated


air conditioner is calling for cooling

6. Padlock means the control functions are locked by


the Child Lock.

CHILD LOCK
This function is designed to be a simple mechanism
to lock the control to prevent unnecessary
adjustments to the system. When the lock is engaged
there will be no system functions available

• To engage the Child Lock press and hold the UP


and DOWN buttons together for 3 seconds. The
padlock symbol will be displayed on the screen
when the child lock has engaged.

• To remove the child lock press and hold the UP


and DOWN buttons together for 3 seconds. The
padlock symbol will disappear from the screen
display when the child lock has been removed.

Bonaire Control Systems Page 10


Multi-Appliance Manual Control

Navigating the Controls

RESET
The reset function is only required if the system has
had a problem and reports a fault code. This will be
indicated with Err and F1:_ _. The requirement for
reset will generally only appear with ducted gas heating
if there has been some form of electricity or gas
interruption.
To RESET the unit, turn the control OFF then ON. If
the unit does not reset call for service.

CLOCK SETUP

To set the 12 hour clock


STEP 1 Turn the control to OFF
STEP 2 Press the UP or DOWN button until the
2 dots are solid to enter clock setup
(approximately 3 seconds).
STEP 3 Using the UP button to adjust the
hours.
STEP 4 Using the DOWN button to adjust the
minutes.
Time setup is now complete. Turn
control ON to resume operation of your
product.

FAULT CODES
The manual control can recover the last 4 faults that the
unit diagnostics has stored.
When a product fault has occurred that requires the unit
to be reset, the last fault will be displayed on the screen
automatically. This will be in addition to the 4 faults
already held.
Should you require a service call on your product
please have this code ready for our service operator.
To reset the unit and clear the fault, simply turn the
control OFF then ON. Where possible the unit will
resume operation immediately.

Bonaire Control Systems Page 11


Multi-Appliance Manual Control

Ducted Gas Central Heating


Ducted Gas Central Heating

Owner’s Operation and Maintenance Manual

Please keep this important manual in a safe place. It is the owner’s responsibility to
ensure that regular maintenance is carried out on this Ducted Gas Central Heater. Failure
to do so will void all guarantees beyond statutory and legal requirements.

www.climatetechnologies.com.au

Bonaire Control Systems Page 12


Multi-Appliance Manual Control

Ducted Gas Central Heating

Congratulations on purchasing this ducted gas central heating system, an exciting new product
manufactured by Climate Technologies.

Wholly designed and manufactured in Australia, this Ducted Gas Central Heater represents an
exciting new development in warm air furnace design. It embodies the latest advances in gas
heating technology.

Your heater is supported by Climate Technologies, Australia’s most advanced manufacturer of a


complete range of climate control products.

To ensure you fully enjoy the benefits of this Ducted Gas Central Heater, please read these
instructions carefully and keep them handy for future reference.

Operated and maintained in accordance with this manual, this unit will provide you with years of
warm and environmentally friendly operation. Please take the time to read this manual.

SAFETY
SAFETY & OWNER RESPONSIBILITY
The manufacturer and its service providers reserve the right to refuse service unless safety and
accessibility to the unit can be guaranteed. The cost of any extra equipment required to provide
access to the unit for servicing is the responsibility of the owner.

PRECAUTIONS.
DO NOT PLACE ARTICLES ON OR AGAINST THIS APPLIANCE.

DO NOT USE OR STORE FLAMMABLE MATERIALS NEAR THIS APPLIANCE.

DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHILE IT IS IN


OPERATION.

DO NOT PLACE ARTICLES IN FRONT OF OR OVER THE RETURN AIR GRILLE.

FEATURES.
Your Ducted Gas Central Heater has all the safety devices to ensure safe operation. These
devices conform to the standards set out by the Australian Gas Association.

POWER OR GAS INTERRUPTION.


Should there be an interruption to the power supply during the heating operation the controls will
automatically turn off the gas.

When the power is restored, the control will be in the OFF position and therefore will not resume
operation until turned ON.

Should there be an interruption to the gas supply, the heater will endeavor to re-light 3 times and
if unsuccessful will lock out. (This is part of the safety features). Should this occur the heater will
need to be reset. If the Err is displayed, turn the control OFF then ON and the unit will be ready
to resume operation.

Please refer to your problem-solving chart to assist resolving other problems.

Bonaire Control Systems Page 13


Multi-Appliance Manual Control

Ducted Gas Central Heating

USING YOUR MANUAL CONTROL WITH DUCTED GAS CENTRAL HEATING


To operate your control simply press the ON / OFF button. The unit will then display the default
or last used settings and will be ready to operate. Any changes made to the control settings will
have a 3 second delay before the unit responds.

If the heater is connected in conjunction with an evaporative or Dual Cycle refrigerated air
conditioner you may have to toggle through the modes to select the heating functions.

To select one of the modes below, simply push the MODE button until the screen displays the
required settings. The following modes are available for the heater:

HEATING OPERATION
STEP 1 To turn the control on, press and release the
ON/OFF button. If there is only a central heater,
HEAT will automatically display.

NOTE: You Control is designed to automatically


detect the appliances you have installed.
Controller options not required for your
appliances will not be visible on your control
display. So don't worry if you don't see all the
mode items listed in this book.

STEP 2 Pressing the MODE button allows you to cycle


through the available options. Select HEAT.
After 3 seconds the option will be accepted.

Available Options will be HEAT, COOL (Dual


Cycle Refrigerated Cooling if fitted), COOL with
continuous fan, and the fan and bars (Room air
fan only).

STEP 3 Press the UP DOWN buttons to increase or


decrease the SET TEMP .

STEP 4 The control measures the room temperature


using a thermostat inside its housing. When the
ROOM TEMP is cooler than the SET TEMP the
heater will come on after approximately a 30
second ignition process. The flame symbol will
be displayed on the control to indicate the heater
is on followed by the fan symbol when the fan
comes on.

The control will run the heater until it measures


temperature a little above your SET TEMP. The

Bonaire Control Systems Page 14


Multi-Appliance Manual Control

Ducted Gas Central Heating

unit will turn off until the temperature falls a little


below SET TEMP before restarting.

STEP 5 Press the ON/OFF button to switch the heater OFF.

STEP 6 The control remembers your SET TEMP setting


and uses it next time you turn it ON.

The operation of the modulating heater is as follows:

• If at start up the temperature is 2.0° or more below the room temperature, the
central heater will start up at high fan speed and high gas rate quickly bringing
your house up to temperature.

• As the room temperature gets closer to the SET TEMP the central heater will
reduce the room air fan and the gas rate to the burner.

• When the thermostat reaches the SET TEMP the central heater will be on
low fan and the gas will modulate to low fire.

• When the temperature has gone over the SET TEMP by approximately 0.5°
the central heater will shut down.

• When the temperature has dropped to approximately 1° below SET TEMP


the unit will restart.

• As your activities vary, you may find you need different temperature settings,
e.g. a temperature comfortable for sitting is usually too warm compared to
when your moving about.

• For economical operation, set a low SET TEMP during the day when you are
active. Switch the control OFF when asleep and ON again when awake.

SUMMER FAN (FAN ONLY)


The fan in your heater can be used to circulate the room air
without running the heating. To run the summer fan option:

STEP 1 To select FAN only switch the Controller


ON

STEP 2 Press the MODE button until there are no


mode options showing, but the fan and
bars are selected. After 3 seconds the
room air fan will run.

(Note the room air fan is only circulating


room air, there will be no fresh air content.)

Bonaire Control Systems Page 15


Multi-Appliance Manual Control

Ducted Gas Central Heating

STEP 3 Using the UP DOWN buttons increase or


decrease the bars to adjust the fan speed
to the required level.

SUMMER SHUTDOWN (OPTIONAL)


STEP 1 Switch the control to OFF

STEP 2 Switch the power point OFF at the unit

STEP 3 Turn the gas tap OFF. It is usually located close to


the Heater.

FIRST STARTUP OR RESTART AFTER SHUTDOWN


STEP 1 Switch on the power point to the heater.

STEP 2 Turn on the gas tap in the gas supply line to the
heater.

STEP 3 Switch the control ON

STEP 4 Using the UP DOWN buttons decrease or


increase the SET TEMP. If the SET TEMP is
greater than the ROOM TEMP the heater will
resume operation.

Bonaire Control Systems Page 16


Multi-Appliance Manual Control

Ducted Gas Central Heating

HEATER MAINTENANCE
GENERAL MAINTENANCE

Return Air Grille Filter.

If your heating system has a filter in the return air grille, it is extremely important it is cleaned
every 3 – 4 weeks during the operating period to ensure correct operation of the heating unit.
Failure to do so may cause your heater to stop because of over temperature and cause an
unnecessary service call not covered by warranty.
Electrical

Warning: Before commencing any maintenance work on your unit, isolate the power at
the supply (Fuse Box).

No general maintenance is required to the electrical system.

A Licensed Electrician only should carry out electrical connections and maintenance.

Flue

The flue and cowl assembly should be clean and free of obstructions.

SCHEDULED MAINTENANCE

Note: It is essential that your central heater be maintained in accordance with


Climate Technologies requirements. Failure to do so will affect the life of the
product and reduce the level of efficiency which may also affect your warranty.

Your Ducted Gas Central Heater should be serviced at least every 2 years to ensure trouble
free operation.

1. To ensure that your heater continues to operate at peak efficiency it is recommended that
it be periodically serviced by a qualified service technician (for your nearest Climate
Technologies service office refer to Service section of this document).

2. Fan blades, motors, ignition systems and burners should be checked. Heater cabinet and
immediate surroundings should be kept clean and clear.

Bonaire Control Systems Page 17


Multi-Appliance Manual Control

Ducted Gas Central Heating

PROBLEM SOLVING.

Central Heater will not operate!

Question Y/N Solution

Has the unit been run Yes Refer to question 4


1. since installation?

No Check the unit is turned on at the power point and the gas
cock is turned on. Call the installer to commission the unit.

Is the unit installed in Yes Refer to question 3


2. a new home?

No Refer to question 4

Has the installer run Yes Refer to question 4


3. the unit?

No Check the unit is turned on at the power point and the gas
cock is turned on. Call the installer to commission the unit.

Is the SET TEMP Yes Turn the control off then on to reset unit. If the unit still
4. greater that the does not start call for service. (refer to solution 6 for reset
ROOM TEMP? instructions)

No Increase the SET TEMP so the thermostat calls for heat.

Has there been a Yes Reset the unit. This can be done by:
5. known power surge?

Turn the control OFF then ON. The unit should resume
operation.

No Unit should operate normally. If not a service call will be


required.

THIS TROUBLE SHOOTING GUIDE IS A REFERENCE ONLY.

FOR SERVICE OR WARRANTY REQUIREMENTS PLEASE REFER TO

THE WARRANTY SECTION OF THIS BOOK

Bonaire Control Systems Page 18


Multi-Appliance Manual Control

Dual Cycle – Refrigerated Air Conditioning


ADD-ON Refrigerated Air Conditioning

Owners Operating and Maintenance

Please keep this important manual in a safe place. It is the owner’s responsibility to
ensure that regular maintenance is carried out on this Ducted Gas Central Heater / Dual
Cycle Air Conditioner. Failure to do so will void all guarantees beyond statutory and legal
requirements.
www.climatetechnologies.com.au

Bonaire Control Systems Page 19


Multi-Appliance Manual Control

Dual Cycle – Refrigerated Air Conditioning

GENERAL INFORMATION.
IMPORTANT NOTICE.
A licensed person is required to install Climate Technologies equipment. If the equipment is not
installed in a accordance with the installation instructions and the governing body regulations,
Climate Technologies reserves the right to refuse service on non compliant installations.
Subject to state regulations and by laws a certificate of compliance must be issued for the
electrical and plumbing connections certifying that the work complies with all the relevant
standards.
Note: Only a licensed person will have insurance protecting their workmanship.

DATA LOCATION.
Your appliance model number, serial number and model description are located on the appliance
data plate on the end of the ducted gas heater / Dual Cycle air conditioner in the vicinity of the
electronic controls access. These details should also be in the warranty section of this booklet.

You will need this information, should your appliance require servicing, spare parts or just if you
require additional information about this product.

ASSEMBLY.
There is no assembly required of this Add-on Refrigerated Air Conditioner. Your Dealer or
installer will carry out all assembly and commissioning upon installation.

SAFETY
SAFETY & OWNER RESPONSIBILITY
The manufacturer and its service providers reserve the right to refuse service unless safety and
accessibility to the unit can be guaranteed. The cost of any extra equipment required to provide
access to the unit for servicing is the responsibility of the owner.

PRECAUTIONS.
DO NOT PLACE ARTICLES ON OR AGAINST THE CONDENSER.

DO NOT PLACE ARTICLES IN FRONT OF THE CONDENSER.

ENSURE THE CLEARANCES BETWEEN THE UNIT AND WALL ARE KEPT CLEAR.

DO NOT PLACE ARTICLES IN FRONT OF OR OVER THE RETURN AIR GRILLE.

FEATURES.
Your Ducted Gas Central Heater and Add-on Refrigerated air conditioner has all the safety
devices to ensure safe operation. These devices conform to the standards set out by the
Australian Gas Association.

POWER INTERRUPTION.
Should there be an interruption to the power supply during the cooling operation the controls will
automatically shut down.

When the power is restored, the control will be in the OFF position and therefore will not resume
operation until turned ON.

Bonaire Control Systems Page 20


Multi-Appliance Manual Control

Dual Cycle – Refrigerated Air Conditioning

USING YOUR CONTROL WITH DUAL CYCLE AIR CONDITIONING


To operate your control simply press the ON / OFF button. The unit will then display the default
or last used settings and will be ready to operate. Any changes made to the control settings will
have a 3 second delay before the unit responds.

As the Dual Cycle Refrigerated Air Conditioner is connected in conjunction with a ducted gas
central heater you may have to toggle through the modes to select the heating functions.

To select one of the modes below, simply push the MODE button until the screen displays the
required settings. The following modes are available for the heater:

OPERATION
STEP 1 To turn the control on, press and release the
ON/OFF button.

STEP 2 Pressing the MODE button allows you to cycle


through the available options. Select COOL.
After 3 seconds the option will be accepted.

Available Options will be HEAT, COOL (Dual


Cycle Refrigerated Cooling if fitted), COOL with
continuous fan or the fan and bars (Room air fan
only).

There may be up to 5 minutes delay before the


Dual Cycle air conditioner starts if the unit has
already been running.

STEP 3 Press the UP DOWN buttons to increase or


decrease the SET TEMP .

STEP 4 The control measures the room temperature


using a thermostat inside its housing. When the
ROOM TEMP is warmer than the SET TEMP the
fan and Dual Cycle refrigerated cooler will come
on. The snow flake symbol will be displayed on
the control to indicate the condenser is running.

The control will run the Dual Cycle refrigerated


cooler until it measures temperature a little below
your SET TEMP. The condenser will turn off until
the temperature rises a little above SET TEMP
before restarting.

Bonaire Control Systems Page 21


Multi-Appliance Manual Control

Dual Cycle – Refrigerated Air Conditioning

FAN OPERATION
There are 2 modes for operating the fan with dual cycle refrigerated cooling.

• Auto – The fan runs with condenser only. This means when the control reaches temperature
the fan will turn off with condenser. The display will indicate the snow flake when the unit is
running.

• Continuous – The fan runs continuously and the condenser cycles ON and OFF. In this
mode the fan will only shut off when the control is in the OFF mode. The display will show the
snow flake when the condenser is on plus the fan symbol. The snow flake will cycle on and
off with the condenser.

To change the fan mode operation:

STEP 1 Ensure the unit is turned on.

STEP 2 Using the MODE button toggle through the


available modes until you have COOL by itself
(Auto)

or

Using the MODE button toggle through the


available modes until you have COOL with the fan
symbol (Continuous).

The snow flake will only show if the SET TEMP is


lower than the ROOM TEMP.

Bonaire Control Systems Page 22


Multi-Appliance Manual Control

Ducted Evaporative Air Conditioning


Ducted Evaporative Air Conditioning

Owners Operating and Maintenance

Please keep this important manual in a safe place. It is the owner’s responsibility to
ensure that regular maintenance is carried out on this Evaporative Air Conditioner. Failure
to do so will void all guarantees beyond statutory and legal requirements.

www.climatetechnologies.com.au

Bonaire Control Systems Page 23


Multi-Appliance Manual Control

Ducted Evaporative Air Conditioning

INTRODUCTION
Your ducted evaporative air conditioner is engineered to meet the rigors of our harsh Australian
environment. Operated and maintained in accordance with this manual, it will provide you with
years of cool and environmentally friendly operation. Please take the time to read this manual.

The principal of your unit is to introduce fresh air, which is washed through the filter pads to
provided cool fresh air. The air is relieved taking with it any heat loading on the home.

AIR RELIEF
It is essential for successful operation of evaporative air-conditioning that there be sufficient
relief openings in the area to be ventilated. Open doors and windows will usually provide this.

The minimum relief opening should be as per the table guide set out below. It is recommended
that ceiling vents or exhaust fans be used where there is any doubt about there being sufficient
relief area available. Ceiling exhaust fans or ceiling vents should have a capacity equivalent to
that of the air conditioner.

MODEL MINIMUM RELIEF


AREA

Small 0.85 m²

Medium 1.19 m² to 1.48 m²

Large 2.02 m²

Bonaire Control Systems Page 24


Multi-Appliance Manual Control

Ducted Evaporative Air Conditioning

DIALFLO
BEED OFF
All evaporative air conditioners need some water bleed-off to prevent
build-up of mineral deposits in the system. The correct setting of the
bleed rate will ultimately govern the life of the unit.
With normal town water supply, in good water quality areas, bleed rate
should be adjusted so that the discharge is not less than 10 litres per
hour subject to unit size. Increased water hardness may require a
higher bleed rate and increased maintenance.
Setting the BLEED OFF Rate.
To set the bleed rate locate the patented DIALFLO
externally on one of the corner posts. Rotate the BLEED
knob clockwise for more flow and anti clockwise.
Note: Hold the distribution knob (Filler) while setting the
bleed rate as the distribution flow rate may go out of
adjustment.
It is recommended that the bleed water is plumbed away to
waste in accordance with local and state plumbing
requirements.
Setting the Water Distribution Flow Rate
To set the water distribution flow rate to the filter pads,
rotate filter knob anti-clockwise for more water and
clockwise for less water. To control bleed-off rate rotate
bleed dial clockwise for more water and anti-clockwise for
less water.
Note: Hold the bleed knob while setting the distribution rate
as the bleed rate may go out of adjustment.

OPTIONAL DUMP VALVE


If a dump valve is fitted, the dump valve will only be
activated when the pump is turned on or off. There is no
dump time cycles, pre fill or pre cool with this manual
control.
Bleed off may not be required in some areas, however it is
the responsibility of the dealer / installer to correctly
detirmine for your location.
Drainage from the dump valve needs also to be plumbed
away in accordance with local and state plumbing
requirements. Its Climate Technologies recommendation
that the drain form the dump valve is plumbed to waste.

Bonaire Control Systems Page 25


Multi-Appliance Manual Control

Ducted Evaporative Air Conditioning

OPERATING THE MANUAL CONTROL.


To operate your control simply press the ON OFF button. The unit will then display the default or
last used settings and will be ready to operate. Any changes made to the control settings will have
a 3 second delay before the unit responds.

If the evaporative cooler is connected in conjunction with a central heater you may have to toggle
through the modes to select the evaporative cooling functions

To select the one of the modes below, simply push the mode button until the screen displays the
required settings. The following modes are available for evaporative air conditioning.

COOL MODE
Cool mode is pump only. This function is ideal when you want to run the pump to wet the filter
pads before turning of the fan. To select COOL:
STEP 1 Press the ON / OFF button to turn the
unit on.

STEP 2 To select COOL (Pump only) press the


MODE button until COOL is selected.
The pump will begin to operate and the
water droplets will appear on the
screen.
If COOL FRESH AIR mode is not
selected within 15 minutes the control
will turn off.
STEP 3 To turn the pump off press the ON OFF
button.

COOL FRESH AIR MODE


COOL FRESH AIR is the pump and fan operating together giving cool fresh air. To select COOL
FRESH AIR:
STEP 1 Press the ON / OFF button to turn the
unit on (if not already on).

STEP 2 To select COOL FRESH AIR (Pump


and Fan) press the mode button until
COOL FRESH AIR is displayed. The
pump and fan will begin to operate
within 3 seconds.
The screen will display the water
droplets for pump, the fan and the bars
for the fan speed.
STEP 3 To adjust the fan speed use the UP
DOWN buttons. The bar will increase
of decrease indicating the nominal fan
speed. There is a 3-second delay
before the new setting is accepted.
STEP 4 To turn the pump and fan off press the
ON OFF button.

Bonaire Control Systems Page 26


Multi-Appliance Manual Control

Ducted Evaporative Air Conditioning

FRESH AIR MODE


FRESH AIR is the fan only operation delivering fresh air with no pump. To select FRESH AIR:
STEP 1 Press the ON / OFF button to turn the
unit on (if not already on).

STEP 2 To select FRESH AIR (fan only) press


the mode button until FRESH AIR is
displayed. The fan will begin to
operate within 3 seconds.
The screen will display the fan and the
bars for the fan speed.
STEP 3 To adjust the fan speed use the UP
DOWN buttons. The bar will increase
or decrease indicating the nominal fan
speed. There is a 3-second delay
before the new setting is accepted.
STEP 4 To turn the fan off press the ON OFF
button.

Bonaire Control Systems Page 27


Multi-Appliance Manual Control

Ducted Evaporative Air Conditioning

DUCTED EVAPORATIVE AIR CONDITIONER MAINTENANCE


GENERAL.
All Ducted Evaporative Air Conditioners benefit from some general maintenance to ensure
continued cooling efficiency and a long life. Maintenance is carried out at the beginning and end
of summer to start up and close down your unit.

We recommend that all maintenance work be undertaken by our fully trained and accredited
Service Technicians or an authorised Climate Technologies Service Provider.

The frequency of general maintenance will depend on local operating conditions such as water
quality, air borne dust and pollen.

It is essential that your evaporative air conditioner is maintained in accordance with this manual.
Failure to do so will affect the life of the product, reduce the level of efficiency and may void
warranty.

For service Australia wide refer to the details on the service section of this manual.

NOTE: The manufacturer and its agents reserve the right to refuse service unless safety
and accessibility to the unit can be guaranteed. The cost of any extra equipment
required to provide access to the unit for servicing is the responsibility of the
owner.

SAFETY: Prior to commencing any maintenance isolate the unit at the power source.
Ensure the roof is safe to access, your ladder is securely positioned and use
suitable safety equipment.

FILTER PADS
Visually check CELDEK pads for damage or blockage. Hose down pads from both
sides to remove any build up of salts, dust and pollen. In dusty areas more regular
cleaning is recommended. Check the water distributor, making sure it is clear and free
from blockage. Failure to do so may lead to uneven water distribution and therefore
less efficient operation.
WATER TANK
It is important to keep the water tank clean and free from sediment and algae growth. To clean
the tank, use a soft brush or similar. Wipe all surfaces in the tank while it is full of water (DO
NOT FORGET THE PUMP STRAINER). Turn off the water inlet to the unit (an Isolation Valve
should be fitted to the water inlet before the Float Valve). Drain the tank by removing the 40mm
overflow pipe. It may be necessary to repeat this procedure if the tank is very dirty.

SAFETY: Wet roofs are dangerous – Take Care When Draining Tank.

WATER LEVEL / FLOAT VALVE


The water level should be set at nominal 65-70mm from the top of the overflow before filter pads
are saturated. After run off from operating filters the level from the top of the overflow fitting
should be 25 – 30mm. The float valve is a mechanical type and is factory set. If it requires
adjustment keep bends tight. If the valve is leaking the seal may require cleaning or replacing.
Turn of the water. Remove the split pin and then float arm. Remove piston and clean or turn
seal. Flush system and replace piston, float arm and split pin.

Note: Water supply line to float valve must be flushed before connecting.

Bonaire Control Systems Page 28


Multi-Appliance Manual Control

Ducted Evaporative Air Conditioning

Note: Some discharge from the overflow may be experienced after shut down due to
water draining back from the Celdek pads. This is normal.

MOTOR AND FAN


Check that the fan spins freely and that there is no build up on the blades.
ELECTRICAL
No general maintenance is required to the electrical system.

A Qualified Electrician should only carry out electrical connections and maintenance.

BLEED OFF
The bleed rate should be checked to ensure it is adequate and that there is no build up
of mineral deposits in or on your air conditioner. White deposits indicate high mineral
content and the Bleed Rate should be increased. If it is at maximum and the deposits
are still forming, then more regular maintenance is required.
PUMP
Check the pump spins freely and that the strainer is clean.

WATER DISTRIBUTION
Check the water distribution system for blockage. Check the delivery tube for kinks or
holes. Check that the clamps are secure and in place.
NO SEASONAL MAINTENANCE
Your unit has been supplied with a dump valve system. As long as the dump valve has been
fitted, there is no need for regular checking of the system during the operating (summer) period.
This however does not remove the responsibility of the customer to have the unit service on an
annual basis to check the unit function and to ensure the unit is clean and free from any mineral
deposit build up.

Bonaire Control Systems Page 29


Multi-Appliance Manual Control

Ducted Evaporative Air Conditioning

TROUBLE SHOOTING GUIDE


PROBLEM PROBABLE CAUSE REMEDY

A Black – out a Wait


b Tripped Circuit Breaker b Reset
Unit fails to start c Blown Fuse c Replace
d Electrical Fault d Call Climate Technologies
Service Provider
a Pump Seized a Isolate power and then take
off top of pump and try to free
Pump fails to
it. Some lubricant may help.
start
b Pump Burnt Out b Call Climate Technologies
Service Provider
a Float Valve Leaking a Check adjustment or replace
Water leaking seal
from overflow b Drain from Celdek Pads b Normal Operation

a Loose Delivery Tube a Check and tighten


Water Droplets in b Break in tubing b Replace as necessary
air stream c Pump Delivers Excessive c Adjust the Dialflo to reduce
Water to Pads the flow
a Inadequate Relief a Provide more open area to
Excessive relieve stale air
humidity
b Outside humidity high b Turn pump off.
a Dirty Filters a Clean / Replace
b Dry Filters b Check water delivery system.
Inadequate
Adjust if necessary.
Cooling
c Dialflo not set correctly c Adjust Dialflo so that the pads
have even saturation.
a Unit located near odor source a Remove source
b New Celdek filter smell b Smell will disappear after a
Unpleasant Odor period of operation
(Approximately 48 hours or
use).
Rapid formation High Mineral Content Bleed off should be set at
of white deposits maximum. More regular
on pads maintenance may be required.
THIS TROUBLE SHOOTING GUIDE IS A REFERENCE ONLY.
FOR SERVICE OR WARRANTY REQUIREMENTS PLEASE REFER
TO THE LAST PAGE OF THESE INSTRUCTIONS

Bonaire Control Systems Page 30


Multi-Appliance Manual Control

Controls – Installation / Setup / Commissioning


Control setup

SETTING UP THE CONTROL - GENERAL


BEFORE STARTING
Before attempting to use the setup instructions for the controls system, make sure the low voltage
cable is connected and the 240 volt power has been turned on to the heater / cooler.
The Low voltage controls are connected to the unit control box / controller via a 20-metre low
voltage loom.

NOTE: Do not run the low voltage loom in long parallel runs with 240V mains cables.
Keep the low voltage loom 200mm away from any long runs of mains wiring.
Cross over mains wiring at right angles.
Do not use existing access holes in wall cavities where 240V mains wiring exists.
Drill a new access hole 200mm from the existing hole.

INSTALLATION
Where the control is using the thermostat for operation (Gas Central Heating and Dual cycle
Refrigerated Air Conditioning), it must be installed approximately 1.5 metres above the floor level
on a room wall which is most commonly used for best average sensing.

Secure the control back panel to the wall using screws and plugs.
Do not locate control near concealed hot or cold water pipes, warm air ducts, radiators, sunlight,
or draughts from hallways, stairways or fireplaces and seal against draughts through wall cavities.
These can all affect the temperature.

Bonaire Control Systems Page 31


Multi-Appliance Manual Control

Controls – Installation / Setup / Commissioning

USING THE SETUP MODES


There are a series of available parameters that can assist the installer to set the unit up to
specification and tailor the control to meet the customer’s requirements. Carefully read these
instructions before entering the maintenance modes. These set up features cover Ducted
Evaporative Air Conditioning, Ducted Gas Central Heating and Add-on Refrigerated Air
Conditioning.
The Setup modes include:
Diagnostics – All products
Fan Speed Settings – All products

PRODUCT IDENTIFICATION
The setup mode will cater for many options of heating / cooling unit configurations. As a result
there are a number of potential product classes that the manual control system will control. The
class is the first requirement for selection when coding or entering the setup mode.
Ducted Gas Heating Only HEAT
Dual Cycle Refrigerated Air Conditioning COOL
Ducted Evaporative Air Conditioning COOL, FRESH AIR
Ducted Gas Heating and Evaporative Air Conditioning. HEAT, COOL FRESH AIR

CODING
AUTO-CODING
The manual control is only capable of controlling 1 product at a time. Options / combinations
available are:

To code the unit communications:

STEP 1 Ensure the control and communication cable(s) are connected.

STEP 2 The moment the power is applied to the control system, the control will scan for
all the new equipment that has been installed and powered on.

STEP 3 The powering up of a multiple configuration, a ducted central heater and a ducted
evaporative air conditioner, must happen within 10 seconds of each other for the
scan to find both units.

MANUAL CODING
If the scan misses one of the units in a multiple configuration or you are adding a new product to
the configuration:

STEP 1 Turn the thermostat ON.

STEP 2 Press and hold the ON / OFF button for 3 seconds


to scan for the available products.
All the segments will be displayed during the
coding period.

Bonaire Control Systems Page 32


Multi-Appliance Manual Control

Controls – Installation / Setup / Commissioning

IMPORTANT NOTES
Things to note when connecting new products to a manual control
1. Central Heating will have a default configuration that includes add-on cooling.
2. When a ducted evaporative air conditioner is added to a ducted central heater, the add-on
cooling functions are no longer available for use.
3. The auto coding process can only discriminate between a single central heater and a
single evaporative air conditioner
CALIBRATING THE THERMOSTAT.
The thermostat comes pre-calibrated from the manufacturer. However, should the thermostat
require re-calibrating, the following is the procedure.
STEP 1 Remove the control from the mounting panel
STEP 2 Power down the thermostat by disconnecting
the comms loom.
STEP 3 Reconnect the comms loom to the thermostat.
STEP 4 Wait 10 seconds for the control to complete
the autocode and then press the ON/OFF to
enter the temperature setting
STEP 4 On the control board adjust the room temperature by rotating the temperature
calibration knob.
There is only 20 seconds available after power up to make the adjustment. To
further adjust repeat steps 2 and 3.
STEP 5 Replace the thermostat to the mounting base.

FAULT CODES ACCESS


The manual control can recover the last 5 faults that the unit diagnostics has stored when viewed
through the auto mode. Fault code F1 is the current registered fault flashing on the screen, while
F2, F3, F4 & F5 is the fault code history. Once the current fault is viewed and the unit is reset, the
fault becomes part of the last 4 fault code history.
• To reset the unit, simply turn the control OFF then
ON. Where possible the unit will resume operation.

VIEW THE FAULT CODES


There are a number of fault codes that can be registered
subject to the failure or the product associated.
STEP 1 Select the product using the mode
button e.g. HEATER
STEP 2 To enter the fault code log, press the
DOWN and MODE buttons together.
STEP 3 Using the UP DOWN buttons scroll
through the fault log.
The last fault code number will be
displayed with number F1 and the fault
code. Number F1 is always the most
recent fault. See the fault code table
below.
STEP 4 To exit press the ON / OFF button.
STEP 5 Reset the unit by turning the control
OFF then ON.

Bonaire Control Systems Page 33


Multi-Appliance Manual Control

Controls – Installation / Setup / Commissioning

EVAPORATIVE AIR CONDITIONING SETUP

Fan Speed Options

Installer Maintenance Default Value Range

Low Fan Speed 13 0 – 35

High Fan Speed 35 0 – 35

SETTING THE FAN SPEED


Setting of the fan speed should be done by a Climate Technologies trained installer or service
provider. If the motor fan speed is set too low and a motor burnout occurs, Climate Technologies
reserves the right to charge the customer for the cost replacement.

To adjust the minimum fan speed setting

STEP 1 Turn the control ON and select COOL FRESH


AIR.
STEP 2 Using the DOWN button, adjust the fan speed
to the lowest setting.
STEP 3 Press and hold the ON / OFF button and the
DOWN key for 8 Seconds.
The default low fan speed will be displayed.
STEP 3 Using the UP / DOWN buttons, adjust the low
fan speed setting between 1 - 35. The new
speed will be saved within 3 seconds of the
last change.
STEP 4 To exit press the ON OFF button
or
To adjust the high fan speed, press the
MODE button.
The default high fan speed will be displayed.
STEP 5 Using the UP / DOWN buttons, adjust the
high fan speed setting between 1 - 35. The
new speed will be saved within 3 seconds of
the last change.
NOTE: Using the MODE button you can
toggle between high and low fan speed
settings.
STEP 6 To exit press the ON OFF button.

Note: Each time the fan speed adjustment is used, the fan speed will revert
to the default setting, not the last saved setting.
.

Bonaire Control Systems Page 34


Multi-Appliance Manual Control

Controls – Installation / Setup / Commissioning

DUCTED GAS CENTRAL HEATING

Fan Speed Options

Installer Maintenance Default Value Range

Low Fan Speed 27 0 – 35

High Fan Speed 35 0 – 35

High Fan Speed – Dual Cycle AC 35 35

SETTING THE FAN SPEED


Setting of the fan speed should be done by a Climate Technologies trained installer or service
provider. If the motor fan speed is set too low and a motor burnout occurs, Climate Technologies
reserves the right to charge the customer for the cost replacement.

To adjust the fan speed setting

STEP 1 Turn the control ON and select HEAT.


STEP 2 Adjust the set temperature to 28° and wait for
the heater to be fully operational.
STEP 3 Press and hold the ON / OFF button and the
DOWN key for 8 Seconds
The default high fan speed will be displayed
STEP 4 Using the UP / DOWN buttons, adjust the
high fan speed setting as required between 1
- 35. The new speed will be saved within 3
seconds of the last change.
and / or
Using the MODE button, toggle to the LOW
fan speed setting.
The default low fan speed will be displayed.
STEP 5 Using the UP / DOWN buttons, adjust the low
fan speed setting between 1 - 35. The new
speed will be saved within 3 seconds of the
last change.
NOTE: Using the MODE button you can
toggle between high and low fan speed
settings.
STEP 6 To exit press the ON OFF button

Note: Each time the fan speed adjustment is used, the fan speed will revert
to the default setting, not the last saved setting.

Bonaire Control Systems Page 35


Multi-Appliance Manual Control

Controls – Installation / Setup / Commissioning

COMMISSIONING CHECK LIST


GENERAL

† All equipment ordered by the customer is installed.

† The unit is level and secure.

† The mains and control wiring are complete and the circuit breaker and GPO are turned ON.

† All Controller functions for the appliance operate.

† All electrical or gas connections are to manufacturers specifications and the relevant electrical
or gas standards and codes.

UNIT - DUCTED EVAPORATIVE AIR CONDITIONER

† The water supply line has been flushed to clear swarf and debris and is free of leaks.

† The tank is free of foreign matter and debris and the water isolating tap is turned ON.

† Water drainpipe work is completed and sealed.

† The water basin fills with water and the float valve closes correctly when the water level is 65-
70mm below the overflow level.

† The water pump operates correctly when turned ON at the controller.

† The Dialflo water bleed rate is adjusted to suit local water conditions.

† The Superclean Dump Valve (option). The tank drains correctly when unit turns off.

† The fan deck is correctly located and the fan blade spins freely.

† The fan operates through the entire speed range.

† The minimum fan speed is correctly set.

† Water distribution is even with the filter pads fitted and the air conditioner operating pump and
fan.

UNIT – DUCTED HEATING


† Electrical polarity of the power outlet is correct.

† Heater is installed away from sources of dust and fumes (i.e. pool chlorine/petrol etc).

† Gas leaks checked for, none present.

† Flue outlet pipe complies with limits given / code and is sealed waterproof.

† Combustion air meets requirements (internal, under floor).

Bonaire Control Systems Page 36


Multi-Appliance Manual Control

Controls – Installation / Setup / Commissioning

† Fan speed set is correct.

† Burner pressure is correct.

† Mounting pad/platform complies with requirements / codes.

UNIT – DUAL CYCLE REFRIGERATED AIR CONDITIONING

† Unit Foundation correct

† All pipe work is welded and vacuumed down.

† Condenser Coil is purged before charging.

† System is charged, all joints checked and pressures set correctly

† Condenser unit is level

† All clearances around the condenser set to manufacturer's specifications.

DUCTWORK

† All ductwork is completed to plan, correctly supported and airtight, with no bend less than 1.5
x the ductwork diameter.

† Air distribution checked, dampers are adjusted and all outlets correctly adjusted and wiped
clean.

† All roof penetrations are fully sealed and watertight.

† Man hole cover replaced.

SITE

† All rubbish has been removed from inside and on the roof.

CUSTOMER HAND OVER

† The operation of the Controller.

† The need to open windows and doors for the correct operation of Evaporative Air
Conditioning

† The operation of the bleed or dumping system and it’s importance to operate at all times in a
ducted evaporative air conditioner.

† Maintenance requirements

Bonaire Control Systems Page 37


MULTI-APPLIANCE TOUCH PAD

Warranty – Australia
Warranty

IMPORTANT:
Please read this warranty information and complete the Dealer/Product information on the
following page. KEEP this with your original purchase documents for any claim under warranty.
Firstly refer to your owners manual to ensure you have followed the correct operating procedures
of your product, and refer to the trouble shooting guide to assist solving any problems you may
have.
1. Read this warranty statement carefully before you request warranty service as items
relation to installation are not covered by this appliance warranty.
2. A proof of product purchase must be provided for warranty service, to validate the
appliance is within the manufacturer’s warranty periods.
3. This warranty is only for products and associated original controls for Climate
Technologies manufactured product.
4. Only an authorised Climate Technologies service provider must carry out warranty
service.
Climate Technologies provides the following Manufacturers warranty additional to all implied
warranties and other statutory rights which you may have under the Trade Practices Act and
similar State & Territory Laws, subject to the following terms and conditions.
Conditions to warranty
• Subject to the exclusions noted, Climate Technologies warrant the product for the period
as prescribed in the table following this statement to be free from Inherent defects in
materials and workmanship for functional and structural components.
• This product is only valid if the product is operated in accordance with the manufacturers
instructions
• The appliance must not be modified or changed in any way.
• Your proof of purchase MUST be produced before free service will be provided.
• Traveling time and mileage are included within 30km of either your authorised Climate
Technologies dealer or service provider’s premises. Customers in areas other than the
above are responsible for any traveling time and mileage required to carry out warranty
repairs.
• The product must be installed by a qualified person in the manner prescribed by local &
statutory regulations and to the manufacturer’s specifications.
• Service within the terms of this warranty will be recognised where we are satisfied that the
appliance or part was supplied within the relevant time limits. Documents of purchase
and Dealer/Installer information will assist in this process.
• Product fitness for purpose and overall system design / sizing is solely the responsibility
of the dealer / installer. This includes but is not limited to heat load calculations, air flow,
system balancing, humidity, water quality etc.

The product must be installed in an easily and safe accessible area for service,
appliances installed in areas not easily and safely assessable, costs will be borne by the
owner for access equipment should maintenance be required.
DIY installation Warranty

If the product has been installed as a DIY, a supply part only warranty will apply. Parts
only will be supplied free of charge on the return of the faulty part and the owner will be
responsible for all labour charges incurred for the part to be fitted by a qualified person.
Labour warranty as prescribed in the following table is void in this situation.
Remote Location Warranty
• If the product has been installed outside the Climate Technologies service network, a
supply part only warranty will apply. Parts only will be supplied free of charge on the
return of the faulty part and the owner will be responsible for all labour charges incurred
for the part to be fitted by a qualified person. Labour warranty as prescribed in the
following table is void in this situation.

Bonaire Control Systems Page 38


MULTI-APPLIANCE TOUCH PAD

Warranty – Australia

Exclusions to warranty
• Consumable items subject to wear and tear such as filter pads, drive belts and bearings
are not covered by this warranty.
• Components used as part of the installation such as grilles filters, ducting, fittings, zone
motors and consumer services pipe work are warranted from your place of purchase and
not covered by this warranty.
• Damage caused by elements such as wind, rain, lighting, floods etc along with power
spiking and brownouts are not considered defective material or workmanship and as such
are not considered warranty.
• No responsibility will be accepted for outside elements such as pests, animals, pets and
vermin that may cause damage to the unit.
• Harsh environmental situations such as salt air that may cause cabinet damage / rusting
can not be considered warranty.
• The manufacturer does not accept liability or any claims for damage to building contents,
carpet, walls, ceilings, foundations or any other consequential loss either direct or indirect.
Damage resulting from, power spikes, incorrect operation, incorrect installation, and
incorrect maintenance is also not covered.
• All warranties are NOT transferable.
Conditions where warranty may be void
• If there is no certificate of compliance for plumbing, electrical or refrigeration as required
by State & Territory Laws. Climate Technologies reserves the right to refuse service on
non-compliant installations.
• The defective operation of the appliance that is due to failure of electricity, gas, water or
refrigerant gas supplied.
• Defects are caused by neglect, incorrect application, abuse or by accidental damage of
the appliance.
• An unauthorised person has attempting to repair the appliance.
• A situation arises referenced in the trouble-shooting guide.
• A charge will be made for work done or for a service call where there is nothing wrong
with the appliance.

Bonaire Control Systems Page 39


MULTI-APPLIANCE TOUCH PAD

Warranty – Australia

PERIODS OF WARRANTY – YEARS BY PRODUCT AND APPLICATION:


Ducted Gas Heating

Unit Components RESIDENTIAL COMMERCIAL


Parts Labour Parts Labour
Heat Exchanger 10 3 2 2

Burner 10 3 2 2

**All other components 3 3 1 1


** Return air filter/s and zone motors are field supplied and therefore are not covered by the above warranty
periods.

Dual Cycle Refrigerated Air Conditioning

Unit Components RESIDENTIAL COMMERCIAL


Parts Labour Parts Labour
Compressor 5 5 2 2
**All other components 5 5 2 2
** Return air filter/s and zone motors are field supplied and therefore are not covered by the above warranty
periods.

Ducted Evaporative Air Conditioning - Domestic

Unit Components RESIDENTIAL COMMERCIAL


Parts Labour Parts Labour
Corrosion on 25 3 2 2
Cabinet
Structural 10 3 2 2
Guarantee
** All other components 3 3 1 1
** Filter pads are a consumable and are therefore not covered by this warranty

Aged New Product Warranties


For a New Product warranty to apply, a product needs to be sold and installed within 3 years of
the manufacturing date.
Product that is aged as the result of extended storage or being used for demonstration purposes,
the following warranty will apply.
• For a product that is greater than 3 years and less than 5 years old from date of
manufacture the statutory warranty will apply and any voluntary warranty originally
supplied will be reduced by 1 year
• For a product that is greater than 5 years of age from date of manufacture, the statutory
warranty will apply to electrically functioning components only. All other components
being cabinets, louvres, filters etc. will not be covered by warranty.

WARRANTY ON REPLACEMENT PARTS:


Parts replaced under warranty are warranted for the balance of the original warranty period.

Bonaire Control Systems Page 40


MULTI-APPLIANCE TOUCH PAD

Warranty – Australia

PROOF OF PURCHASE:
It is important that the name of the Dealer or Retailer from whom you purchased your product
and the name of the installer are recorded on this page. The installer is responsible for the
correct installation, start up and demonstrating the operation of this product. The Dealer or
retailer is also responsible for issuing the relevant certificates of compliance for the electrical
connections. (These may differ from state to state)
Please attach your proof of purchase here. Your receipt is your warranty and will be required to
validate any warranty.

DEALER PRODUCT INFORMATION:

Dealer/Retailer:

Dealer Address:

Dealer Phone Number:

Unit Model Number:

Serial No:

Date Installed:

Serial No:

Date Installed:

Serial No:

Date Installed:

Installed by:

Date Commissioned:

Commissioned by: Signature:

Bonaire Control Systems Page 41


Multi-Appliance Manual Control

Service - Australia
SERVICE

SERVICE CENTRES:
Only qualified service personnel should conduct any service work carried out on your heating /
cooling ducted system. It is important that periodical service is carried out on your product to
ensure your will receive the efficiency benefits the product provides.
For Metro Service only ring the numbers below.

South Australia/ (08) 8307 5230


Northern Territory

New South Wales / (03) 8795 2457


Australian Capital Territory

Western Australia (08) 9454 1000

Victoria/Tasmania (03) 8795 2456

Queensland (03) 8795 2457


Outside Metro areas please contact your nearest Climate Technologies Service Provider.
New Zealand (ABERGAS LTD) 0800 161 161

Bonaire Control Systems Page 42


Multi-Appliance Manual Control

Service - Australia

Bonaire Control Systems Page 43


Manufactured by
Climate Technologies
ABN 13 001 418 042
26 Nylex Avenue
Salisbury, SA 5108
Australia

www.climatetechnologies.com.au

5312270/E