Vous êtes sur la page 1sur 2

REYROLLE- the economical solution for your distribution network

ARGUS-C
ARGUS-C Overcurrent and Directional Overcurrent Protection

Overcurrent and directional overcurrent protection


Latest Technology
Under the well established REYROLLE brand we have incorporated our accumulated experience in
protection to provide a well known product on the latest hardware platform to secure your present and
future needs.

High Flexibility
Highly comprehensive protection functionality complemented by an advanced range of integral application
functions reduces installation, wiring and engineering time.

Efficient Investment
Protection, Monitoring, Instrumentation and Metering with integrated input and output logic, data logging
& fault reports are all provided within this small housing.

Easy to Use
User friendly operation with a familiar look and intuitive feel allow the relay to be programmed quickly,
without additional training.

All the functions you need in one small case


REYROLLE- the economical solution for your distribution network

ARGUS-C
ARGUS-C Overcurrent and Directional Overcurrent Protection
7SR11 & 7SR12 Overcurrent Relays
Key Features 37
46BC
Undercurrent
Broken Conductor / Load Unbalance

Overcurrent and directional overcurrent protection


I Comprehensive Functionality 46NPS Negative Phase Sequence Overcurrent
49 Thermal Overload
I Familiar Operation - No learning curve
50 Instantaneous Overcurrent
I One Interface Software Package 50G/N/SEF Instantaneous Measured/Derived/Sensitive Earth Fault
50BF Circuit Breaker Fail
I Programmable From Fascia - No PC required
51 Time Delayed Overcurrent
I Withdrawable 51G/N/SEF Time Delayed Measured/Derived/Sensitive Earth Fault
60CTS CT Supervision
I Protective Cover
64H High Impedance REF
I Password Security 74TC/CC Trip & Close Circuit Supervision
81HBL2 Inrush Detector
I Display Text - User programmable
86 Latched Tripping
I Large Display
7SR12 Directional Overcurrent Relay Additional Functions
27/59 Under/Over Voltage
47 Negative Phase Sequence Voltage
51V Voltage Controlled Overcurrent
59N Neutral Voltage Displacement
60VTS VT Supervision
67/50 Directional Instantaneous Overcurrent
67/50G/N Directional Instantaneous Earth Fault
67/51 Directional Time Delayed Overcurrent
67/51G/N Directional Time Delayed Earth Fault

Optional Functionality

7SR11 & 7SR12 Overcurrent Relays


79 Auto Reclose

Key Functions Communications


IEC60870-5-103
Hardware Variants
1 or 4 Current Inputs Options
I 1000 Events, 10 Fault Records and MODBUS RTU 3 Voltage Inputs - Optional
DNP3.0 3 or 6 Binary Inputs
10 Disturbance Records REYDISP 5 or 8 Binary Outputs
I Multi-coloured LEDs
Application Functions User Interface
I User Selectable Events
CB Control & Monitoring Five Navigation Keys
I User Logic Equations Cold Load Settings 4 Line x 20 Character Display
User Programmable Logic Equations Relay Healthy LED
I User Alarms on LCD
Virtual Inputs & Outputs 9 Tri-coloured User Defined LEDs
I USB Front Port / RS485 Rear Port Self Monitoring
I IEC60870-103, MODBUS & DNP3.0 Password Protection
Four Setting Groups

www.reyrolle-protection.com