FOR PHOTOI\,IETRIC DATA SEE REVERSE SIDE c4213TW

150,250W PAR 38 INCANDESCENT

JUNCTION BOX UL LISTED FOR THROUGH


BRANCH CIRCUIT WIRING AND DAMP LOCATIONS 20 GA, BONDERIZED STEELHOUSING
REMOVABLE THROUGH CEIL]NG BAKED
ON MATTE BLACK FINISH
FINNED DIE CAST ALUMINUA,4 HUSK

F1 FXIBLE CONDUIT

s BLACK SPECULAR ALZAK CONE


QUICK BRACKETS WITH RETURN FLANGE
O (1 t/,' CAR RtNG CHANNELS

BY OTHERS)
9

TH E B M AL C UT.OUT STAN DAR D


g)

111/4"
T-l
U I
I !
D I
! I
I !
!
SCALE %': 1'

7"---------------- l
7Y2'
831a"

STANDAF]D FLANGE OPTIONAL FLANGES

N,4OUNTING PAN DII\,4ENSIONS

[- c4213TW i I C4213TW FF r c4213TW FW t- C4213TWF


Feturn Flange F at Flange White Flange Flangeless

OPTIONS ADDER OPTIONS ADDEB


F at Flange . . FF S oped Ce nq Adaplor 5', 10', t5', 20',
Wh te Flanqe .. .. FW 25', o,30'

o Flangeess ......
Paracone colors:
Grey........
Gold......
Bronze
.... F

GR
GO
aR
tll
lr4-l

Jr{
.
I Clear C
f ... Mountinq Pan Less Juncl on Box . Delele Tw
Supp ed w lh 5 oi W re Leads

LDIVI-7" API SEC 1 pg. l1


o M E G A
LIGHTING
c4213TW
150 25OW PAR 38 ]NCANDESCENT
PHOTOMETRIC DATA

SOUBCE: INCANDESCENI LAMP: 150W PAB-38/SP SOURCE: INCANDESCENT LAMP:150W PAR-38/FL

TOT. LUIvIENS:1740 TEST NO. F01025 TOT. LUMENS:1740 TEST NO. FO1O24

CAN DE LA DISTHIBUTION CANDELA DISTRIBUTION


DISTBIBUTION CURVE DISTRIBUTION CURVE
00
0 8795 0 3676
7441 3242
t0 3909 10 2795
15 r 550 t5 2060
2A 664 2A 1122
331 25 459
30 r05 30 126
35 21 35 r6
40 0 40
45 0 15 0
50 0 50 0
55 0 55 0
75 0 0
90 0 O-DEG.
0

ZONAL LUMEN SUMMARY ZONAL LUMEN SUMMARY


ZONE LUMENS % LAMP % FIXT ZONE LU II4ENS O/O
FIXT
030 1247 71 7 983 030 1086 625 976
040 1269 73 0 100 0 040 tft 639 99.9
0- 60 1269 73 0 100 0 0-60 11r 3 64 0 100 0
090 1269 73 A 100 0 090 1113 64 0 100 0
90.180 0 0L) 00 90-180 0 00 00
0 1n0 1269 73 0 100 0 0 180 1ll3 640 100 0

TOTAL LUMINAIBE EFFICIENCY = 73.0% TOTAL LUMINAIRE EFFICIENCY = 64.0%


CIE TYPE DIRECI CIE TYPE _ DIBECT
LUMINAIBE SPACING CFITERION = 0.3 LU|\rllNAlFE SPACING CRITERION = 0.5

ZONAL CAVITY METHOO ZONAL CAVITY I\4ETHOD


COEFFICIENTS OF UTILIZATION COEFFICIENTS OF UTILIZATION
FFFFCTIVF FIOOF CAVITY RFFL FCTANCF O 20 EFFECT VE FLOOB CAVITY REFLECTANCE O 20

FC 80 70 50 30 10 0 RC 80 70 50 30 l0 0
FW 70 50 30 l0 70 50 30 10 50 30 t0 50 30 10 50 30 10 0 RW 70 50 30 r0 70 50 30 t0 50 30 10 50 30 r0 50 30 10 0

85 83 82 8l 83 82 8l 80 79 7A 71 76 76 75 71 73 73 72 1 74 73 72 71 72 71 71 7A 69 68 68 67 66 66 64 64 64 63
a3 a1 79 71 a1 l9 7A t-i 17 76 75 75 14 13 13 73 72 71 2 72 7A 6a 67 71 69 68 65 67 66 65 65 64 64 64 63 62 61
a1 78 76 75 8A 78 76 74 76 71 73 74 73 72 73 72 71 7A 3 70 68 66 65 69 67 66 64 66 64 63 64 63 62 63 62 6l 6l
79 76 74 73 ta 76 74 12 t4 73 71 13 12 11 72 71 7A 69 69 66 64 62 68 65 6.1 62 64 63 61 63 62 61 62 61 60 59
TA 75 72 71 17 74 72 70 73 71 7A 72 71 69 7t 70 69 68 67 64 62 6A 66 64 62 60 63 61 60 62 60 59 61 60 59 58
77 73 71 7A 76 73 71 69 72 7A 69 71 70 68 70 69 68 68 6 66 63 6t 59 65 62 60 59 62 60 58 6t 59 58 60 59 58 5T
75 72 7A 6A 75 7l 69 68 7t 69 68 70 68 67 69 68 67 66 7 64 61 59 57 64 6t 59 57 60 58 57 59 58 57 59 58 56 56
8 74 70 68 67 73 70 68 67 70 68 66 69 67 66 68 67 66 65 8 63 60 57 56 62 59 57 56 59 57 56 58 57 55 58 56 55 55
9 73 69 67 66 72 69 67 66 69 67 66 68 66 65 68 66 65 65 I 62 58 56 55 61 58 56 55 58 56 54 57 55 54 57 55 54 54
10 72 68 66 65 7t 68 66 65 68 66 65 67 66 6,1 67 65 64 64 t0 53

LIGHTING PERFOBI\4ANCE DATA LIGHTING PERFORMANCE DATA


SINGLE UN T DATA [/ULIIPLE INSTALLATION S NGLE UNIT DATA MULTIPLE INSTALLATION

BEAN4 ANGLE 37 57 AVEBAGE FOOTCANDLES BEAM ANGLE - 52 74 AVEF]AGE FOOTCANDLES


HEtcltT tNtTtAL HETGHT tNtTtAL
DIAMETEB MAX FTC OF UNIT MAXIMUM LARGE MEDIU[,4 SMALL DAMETEF MAX FTC OFUNLT MAXMUM LABGE MEDIUM SIVALL
LIGHTED INITIAL ABOVE FLOOR SPACING BOOM ROOM ROOM LIGHTED INIIIAL ABOVE FLOOB SPAC NG BOOM ROOM FOOI\I
(FT rN.) (FT) (FT) (r) (5) (s) (Fr, N ) {FT) (FT) (1) (5) (9)

9 2 483 16 11 A7A 745 132 75 654 r0 38 879 792 71 I


t0 6 t8 4/ 650 5.r. 55 95 447 12 48 5.18 494 447
]] t0 247 20 52 5i8 461 436 |4 27 a 14 58 374 337 305
13 3 231 22 s9 41 7 37.6 35 1 13 4 242 16 68 27 1 244 221
147 190 24 65 343 31.0 28.9 153 18 78 206 185 168
SPACING TO MOUNTING HEIGHT RATIO = 0.3 SPACING TO MOUNTING HEIGHT RATIO = O-5
BEAM ANGLE AND OIAMETER CUTOFF AT 1O% OF MAXIMUM BEAM ANGLEANO DIAMETER CUTOFFATlO%OF MAXIMUM
CANDLEPOWEB COEFFICIENTS USED AT EFFECIIVE REFLECTANCES OF CANDLEPOWER COEFFICIENTS USED AT EFFECTIVE REFLECTANCES OF
70% CEILING, 50% WALLS, 20% FLOOR 70./" cEtLtNG, 50% WALLS, 20% FLOOB

APt_SEC 1 rpg 12
FOOTCANDLE READINGS AT WORKING
PLANE 3clr'/ ABOVE FLOOR
o M E G
LIGHTING