Vous êtes sur la page 1sur 2

Introduction Differential

PRX-20/P card reader is a non-contact high performance Yellow light standby state
Wires color Wiring Definition
card reader with ABA (14 & 13 char), standard Wiegand 26 green and red light card reading status
bits and Wiegand 44 bits output format. These units are Green & Black D0+ / Data+ ( RS-422 positive signal level)
mainly used as card reading support for access controllers Light Indications Red & Black D0- / Data- ( RS-422 negative signal level)
and are characterized by their smart and elegant appearance, Model: PRX-20/P Yellow & Black D1+ / Clock+ ( RS-422 positive signal level)
simple wiring and stable performance.
Indication Color White & Black D1- / Clock- (RS-422 negative signal level)
Specifications:
Power on Yellow
Dimensions Model Weight
OK indication Green + 1 beep activated by controller
L120x W45x H21 (mm) PRX-20/P 300 g
Error indication Red + 3 beeps

Power supply Operating Voltage: DC 6V-12V: Wiring


Maximum Current Consumption: 80mA; Wiring color Function
Ambient temperature Operating temperature: -10C ~ +55C;
Red DC 6V-12V
Storage temperature: -10C ~ +60C;
Humidity Operating: 20%~98%; Black GND
Storage: 5%~90%; Brown Data0/Data
Available Output format Standard wiegand 44BIT; Blue Data1/Clock
ABA Synel (14 char);
Orange Green LED
ABA Linear (13 char)
Gray Red LED
Cable description 13 wires #24 wg (50 cm)
White Buzzer
Type of cards Green Se1_EX Output Format wire #1
EM card* reading distance: 50- 80mm (subject to quality of Purple Se2_EX Output Format wire #2
card)
* Any card of 64bit memory array used by H4001 CMOS
integrated circuit, by EM Microelectronic-H4100/4102 or
compatible.
Clock & Data ABA (14/13 char), standard Wiegand 26 bits and
1K ohm
Wiegand 44 bits output format interface, photo coupling seclusion
OC gate output.
RS-422 Differencial outputs: 1K ohm

Connection distance up to 300m.


TTL outputs: up to 15m.
Note: In case of reading errors, 1K ohm pullup resistors can
be added to the Data and Clock outputs (brown and blue
wires).
Operating state: sound-visual state indication

Synel MLL Payway Ltd. Synel MLL Payway Ltd. Synel MLL Payway Ltd.
Output format options
Se1_EX=1, Se2_EX=1 ABA Synel (14 char)
Se1_EX=0, Se2_EX=1 ABA Linear (13 char)
Se1_EX=0, Se2_EX=0 Std. Wiegand 26bits PRX-20/P
Se1_EX=1, Se2_EX=0 Wiegand 44bits
Note: Card Reader
1. Se1_EX=1 or Se2_EX=1 is a free wire, not connected to
any wires.
2. Se1_EX=0 or Se2_EX=0 is a wire connected with GND.
User Manual
Wiegand Output Format
D0 and D1 output “0” and “1” respectively. 4. Connect wires between your PRX card reader and the controller.
When outputting “0”, D0 experiences a negative pulse and Note: To boost the signal it is recommended to use both pull-
when outputting “1”, D1 experiences a negative pulse. up resistors when the distance between the reader and
See the following diagram displaying a negative pulse width the controller is longer than 5 meters.
of TP=100+10 microsecond; with a repetition period of 5. Turn on the power to test. When the power turns on screw the
TW=1000+100 microsecond and 1 microsecond=1/1000000 unit into place.
a second.
Use a #24 parallel. Do not install in a wire casing with
strong current power cords.

Do not expose to direct sunlight, high temperatures, or


strong electromagnetic interferences.
If installed outdoors, a lightning protective device may be
necessary.
In the following diagram C and O stand for 0 or 1. Packing List
E: even check code; O: odd check code
The following items should be found in the PRX-20/P package:
• Color external packing carton with bar code mark, grey/black
internal packing box
• 1 PRX-20/P (with model bar code and date of production)
• Fixing rubber plug and tapping screws: 1 set
The three bytes in the middle of CCCC CCCC, CCCC • Instruction leaflet: 1
CCCC, CCCC CCCC are the swiped badge number, trans- • Warranty Card and Quality Certificate: 1
Cat. no.: 430059
mitted from left (E) to right in sequence.
Document no.: PRX20P-222-01
Installation Updated on 1.5.2013
1. Select a location to install the PRX-20/P card reader. The rec-
ommended height for installation is 1.4m.
2. Prepare an outlet hole (of 15mm) in the installation pane. SYNEL MLL Payway LTD.
3. Drill two 6mm fixing holes to wall and place fixing rubber
plugs into the holes. Yokneam Industrial Park, 2 Hamada St.,
POB 142, Yokneam 2066719, Israel
Tel: +972-4-959 6777 Fax: +972-4-959 0887
Synel MLL Payway Ltd. Synel MLL Payway Ltd. www.synel.com