Subject: PREVENTIVE MAINTENANCE OF PETRON MEGA PLAZA

We are pleased to quote our best for furnishing labor, tools, equipment, consumables and engineering supervision to satisfactorily
perform all works for the above project.

Scope of works to be done by the Contractor:

PETRON MEGAPLAZA
CONDOMINIUM ASSOSCIATION, INC.
358 Sen. Gil Puyat Ave., Makati City
Tel. No. 886-3321, Telefax 813-6569
Description QTY Unit

Preventive Maintenance of 2 X 4 MVA Transformer 1 Php 100,000.00


A. Check up the following
1. Transformer casing from dirts, oil, and gas leak
2. Loose bolts, nuts, connectors on HV and LV
terminals
3. Instrumentation and cooling system
4. Oil level in bushing, tanks, and tap changer
compartments
5. Gas pressures
6. Operation of fans, heaters and compressors
7. Deterioration, rust, or other damage to Bus work and
support structures
8. Solid ground connection
9. Paint condition PCB labels and designation labels
10. Condition of operating platforms

B. Cleaning of High and Low Voltage Bushings, terminals and 1 Php 200,000.00
other accessories
C. Conduct Standard Electrical Testing
1. Insulation Resistance
2. Winding Impedance Test
3. Winding resistance Test
4. Transformer Turns Ratio
5. Transformer Power Factor
6. Polarization Index Test
7. Dielectric Breakdown Voltage (DVS) and dissolve
gas analysis DGA of insulating oil
8. Insulation power factor test
9. Exciting (No Load) current test
10. Supply and charging of Nitrogen gas (If necessary)
11. Reconnection of secondary and primary terminal of
transformer
T & D POWER SYSTEMS CORPORATION
#35 Josefina Subdivision, Mambugan, Sumulong Hi-way, Antipolo City
Tel. Nos.: (632) 6458449/401-9608/468-4676 Fax : (632) 682-2220 E-mail: td-power@yahoo.com

Preventive Maintenance of 34.5 KV HVSG and bus duct 1 Php 100,000.00


A. Inspection of the following:
1. Dressing of fixed and moving contacts
2. Resistance checks
3. Maintenance and lubrication of mechanism (auxiliary
switches, interlocks, and shoot bolts)
4. Contact resistance check
5. Contact touch condition
6. Contact erosion
7. Closing solenoid
8. Mechanical Mechanism
9. Raising / lowering gear
10. Interlocks check, Lubricate
11. Bushing, mechanism, trip testing, cable boxes
B. Retighten accessible contact points of Bus duct
C. Submission of certified test results and recommendations

Preventive Maintenance of 2 X 4000 ATS (Automatic transfer 1 Php 50,000.00


switch) / 2 X 2500 ATS
A. Inspect physical, electrical and mechanical condition
B. Conduct insulation resistance test
C. Conduct contact resistance test
D. Check metering for possible physical damage
E. Functional testing
F. Submission of certified test results and
recommendations
Preventive Maintenance of All Bus duct B2 to 44th floor 1 Php 150,000.00
A. Check alignment of Bus duct system
B. Check and retightening of terminal bolts
C. Cleaning of Bus duct system
D. Retightening of Bus duct joint stacks to its required
torque for Bus duct run
E. Testing and commissioning