REQUIREMENTS
GOVERNING ITEMS OF
WORK OF THE DPWH '
STANDARD SPECIFICATIONS
FOR HIGHWA y~ BRIDGES~
AND AIRPORTS
1998
, ,
Schedule of Minimum Test Requirements Governing
(VOLUME II)
PART C - EARTHWORK
11 <)
Item 201 - Aggregate Base Course
Tests:
1 - Q, Quality Test
Item 204 - Portland Cement Stabilized Road Mix Base Course Amount
Amount of Cement to be added:
6 to 10 mass of dry soil aggregate
Tests:
A Soil Aggregate
For every 300 m3 or fraction thereof:
1 - G, Grading Test
1 - P, Plasticity Test (LlL, PL, PI)
For every 1500 m3 0r fraction thereof:
1 - Q, Quality Test (Grading, Plasticity and Abrasion)
B, Cement
1 - Q, Quality Test for every 2000 bags or fraction thereof
C. Water
D. Mix
120
E. Compacted Base Co~rse
For every layer to 150 mm compacted depth:
1 - D, Field Der.sity Test for every 150 m or fraction thereof
1 - T, Thickness determination for every 150 m or fraction thereof
Tests:
A. Soil Aggregate .
1 - G, Grading Test
Emulsified Asphalt:
1 - Q, QualityTest for every 40 t or 200 drums or fraction thereof
B. Mix
A. Soil Aggregate
1 - G, Grading Test
B. Portland Cement
Tests:
1 - Q, Quality Test
C. Water
D. Mix
For every layer of 150 mm of compacted depth / based on the results of compaction trials
At least one group o,f three in - situ density tests for each 500 m2 or fraction thereof.
For Crushed Gravel or Crushed Stone, 1500 m3 or fraction thereof
1 - F, Fractured Face
B. Cover Aggregates
1- G, Grading Tests
Quantity: .
Quantity:
Choker (Crushed) 10 kg / m2
Tests:
For every 75 m3 / 200 kg a· fraction thereof:
1 - G, Grading lest
1 - P, Plasticity Test (LL, PL, PI)
122
For every 1500 m 3 or fraction thereof:
1 - Q, Quality Test (Grading, Plasticity and Abrasion, Stripping and Bulk Specific Gravity)
1 - F, Fractured Face
B. Bituminous Materials
1 - G, Grading Te",t
Quantity:
1. Using Cut - Back Asphalt - 4.5 to 7.0 m2SS % of total dry aggregate
2. Using Emulsified Asphalt - 6.0 to 10.0 mass % of total dry aggregate
Tests: 1 - Q, Quality Test for every 40 tor 200 drums
C. Mix
Tests:
1 - G, Grading Test
1 - Ext., Extraction
1 - Sty., Stability
D. Hydrated Lime
E. Compacted Pavement
Tests:
D & T (Density and Thickness Tests) - at Least one (1) but note more than three (3) samples
shall be taken.
Tests:
1 - G, Grading Test
B. Mix
Tests:
1 - G, Grading Test
1 - Ext., Extraction
1 - Sty., Stability
C. Hydrated Lime
12~
D. Mineral Filler ,
Tests: For every 75 m3 or fraction thereof:
F. Compacted Pavement
Tests:
D & T (Density and Thickness Tests) - at Least one (1) but note more than three (3) samrles
shall be taken.
Tests:
1 - G, Grading Test
Quantity:
1. Using Cut - Back Asphalt - 4.5 to 7.0 mass % of total dry aggregate
2. Using Emulsified Asphalt - 6.0 to 10.0 mass % of total dry aggregate
Tests: 1 - Q, Quality Test for every 40 t or 200 drums
C. Mix
Tests:
1 - G, Grading Test
1 - Ext., Extraction
1 - Sty., Stability
D. Hydrated Lime
E. Mineral Filler
Tests: For every 75 m 3 or fraction thereof:
F. Compacted Pavement
Tests:
D & T (Density and Thickness Tests) - at Least one (1) but note more than three (3) samples
shall be taken.
, .
Tests:
1 - G, Grading Test
Quantity:
3. USing Cut - Ba,::k Asphalt - 4.5 to 7.0 mass % of total dry .3ggregate
4. Using Emulsified Asphalt - 6.0 to 10.0 mass % of total dry aggregate
Tests: 1 - Q, Quality Test for every 40 t or 200 drums
C. Mix
Tests:
1 - G, Grading Test
1 - Ext., Extraction
1 - Sty., Stability
124
1 - C., Laboratory Compaction
D. Hydrated Lime
E. Mineral Filler
Tests: For every 75 m3 or fr3ction thereof:
F. Compacted Pavement
Tests:
D & T (Density and Thickness Tests) - at Least one (1) but note more than three (3) samples
shall be taken.
Tests:
1 - G, Grading Test
Quantity:
C. Mix
Tests:
1 - G, Grading Test
1 - Ext., Extraction
1 - Sty., Stability
D. Hydrated Lime
E. Mineral Filler
Tests: For every 75 m3 or fraction thereof:
F. Compacted Pavement
Tests: '
D & T (Density and Thickness Tests) - at Least one (1) but note more than three (3) samples
shall be taken.
1 - Q, Quality test
B. Fine Aggregate
Quantity:
125
1 - Q, Quality Tes~ for: Grading, Elutriation (Wash), Bulk Specific Gravity, Absorption. Mortar
Strength)
Five (5) holes per km per lane or five (5) holes per 500 m when 2 lanes are poured
concurrently.
2. Fine Aggregate
Quantity: m3 / m3 of concrete
126
For Rounded For Angulclr
1 - G, Grading Test
3. Coarse Aggregates
Quantity: m 3 I m3 of concrete
For Rounded CA For Angular CA
4. Water
Tests: 1 - Q, Quality Test, if source is questionable
Certificate of Project Engineer
5. Premolded Filler for expansion joints
Tests: 1 - Q, Quality Test on each thickness of filler for each shipment
6. Steel Reinforcement
Tests: 1 - Q, Quality Test for every 10,000 kg or fraction thereof for each size
7. Concrete
Tests: Compressive strength test on concrete cylinder samples. 1 set consisting of 3 concrete
cylinder samples shall be taken from each day's pouring and to represent not more than 75 m C of
concrete or fraction thereof.
c. Reinforcing Steel
Tests:
• Bar reinforcement for concrete for every 10,000 kg 0,' fraction thereof for each size.
1 - Q, Quality Test for Bending, Tension and Chemical Analysis
• Wire and Wire Mesh
- Q, Quality Test
C. Structural Piles
Tests: 1 - Q, Quality Test I Mill Test Certificate
1 - Q, Quality Test
2. Fine Aggregate
Quantity: m3 I m3 of concrete
3. Coarse Aggregates
Quantity: m3 I m3 of concrete
For Rounded CA For Angular CA
4. Water
Tests: 1 - Q, QLJality Test, if source is questionable
Certificate of Project Engineer
5. Premolded Filler for expansion joints
Tests: 1 - Q, Quality Test on each thickness of filler for each shipment
6. Steel Reinforcement
Tests: 1 - Q, Quality Test for every 10,000 kg or fraction thereof for each size
7. Concrete
Tests: Compressive strength test on concrete cylinder samples. 1 set consisting of 3 concrete
cylinder samples shall be taken from each day's pouring and to represent not more than 75 m3 of
concrete or fraction thereof.
B. Reinforcing Steel
Tests:
A. Bar reinforcement for concrete for every 10,000 kg or fraction thereof for each size:
1 - Q, Quality Test for Bending, Tension and Chemical Analysis
1 - Q, Quality Test
128
Item 403 - Metal Structures
Tests:
1 - Q, Quality Test or Mill Test Certificate for each type of materials used
1 - Inspection Report for each type and shipment of metal used
1 - Q, Quality Test
1 - Q, Quality Test
B. Fine Aggregate
Quantity: m3 I m3 of concrete
1 - G, Grading Test
C. Coarse Aggregates
Quantity: m3 I m 3 of concrete
1 - G, Grading Test
D. Water
Tests: 1 .:.. Q, Quality Test on each thickness of filler for each shipment
129
F. Steel Reinforcement
Tests: 1 - Q, Quality Test for every 10,000 kg or fraction thereof for each size
G. Concrete
Tests: Compressive strength test on concrete cylinder samples. 1 set consisting of 3 concrete
cylinder samples shall be taken from each day's pouring and to represent not more than 75 m 3 of
concrete or fraction thereof.
1 - Q, Quality Test
b. Fine Aggregate
Quantity: m3 / m3 of concrete
1 - G, Grading Test
c. Coarse Aggregates
Quantity: m 3 / m 3 of concrete
B. Steel Reinforcement
Tests:
A. Bar reinforcement for concrete for every 10,000 kg or fraction thereof for each size:
1 - Q, Quality Test for Bending, Tension and Chemical Analysis
130
S'. Wire and Wire Mesh
1 - Q, Quality Test
C. Wire Strand
Tests: 1 - Q, for every 20 t or fraction thereof
Alternative Requirement:
1 - set consisting of 3 concrete cylinder samples for not more than 25 pipes cast in the field
and
1 - Inspection Report for each size for not more than 25 pipes cast in the field
1 - G, Grading Test
C. Water
Tests: 1 - Q, Quality Test, if source is questionable
1 - Inspection Report for each size for not more than 25 pipes cast in the field
B. Clay Pipe
Tests:
1 - Pipe for every 200 pieces each size, with a minimum of 2 specimens for strength,
absorption and dimension
1 - Q, Quality Test
b. Fine Aggregate
Quantity: m3 I m3 of concrete
1 - G, Grading Test
c. Coarse Aggregates , .
Quantity: m3 I m3 of concrete
1 - G, Gra(Jing Test
d. Water
Tests: 1 - Q, Quality Test, if source is questionable
1~2
e. Premolded Filler for expansion joints
Tests: 1 - Q, Quality Test on each thickness of filler for each shipment
f. Steel Reinforcement
Tests: 1 - Q, Qua!ity Test for every 10,000 kg or fraction thereof for each size
Tests: Compressive strength test on concrete cylinder samples. 1 set consisting of 3 concrete cylinder
samples shall be taken from each day's pouring and to represent not more than 75 m 3 of concrete or
fraction thereof.
D. Water
Tests: 1 - Q, Quality Test, if source is questionable
133
Certificate of Project Engineer
E. Premolded Filler for expansion joints
F. Steel Reinforcement
Tests: 1 - Q, Quality Test for every 10,000 kg or fraction thereof for each size
G. Concrete
Tests: Compressive strength test on concrete cylinder samples. 1 set consisting of 3 concrete
cylinder samples shall be taken from each day's pouring and to represent not more than 75 m3 of
concrete or fraction thereof.
1 - Q, Quality Test
B. Fine Aggregate
1 - G, Grading Test
C. Stone
D. Water
Tests: 1 - Q, Quality Test, if source is questionable
1 - Q, Quality Test
2. Fine Aggregate
Quantity: m 3 I m3 of concrete
3. Coarse Aggregates
Quantity: m3 I m3 of concrete
4. Water
Tests: 1 - Q, Quality Test, if sowce is questionable
Certificate of Project Engineer
6. Steel Reinforcement
Tests: 1 - Q, Quality Test for every 10,000 kg or fraction thereof for each size
7. Concrete
Tests: Compressive strength test on concrete cylinder samples. 1 set consisting of 3 concrete
cylinder samples shall be taken from each day's pouring and to represent not more than 75 m3 of
concrete or fraction thereof.
Tests:
1 - G, Grading Test
1 - P, Plasticity Test (LlL, PL, PI)
For every 1500 m3 or fraction thereof:
1 - C, Laboratory Compaction Test
For every 2500 m3 or fraction thereof:
1 - CBR, California Bearing Ratio Test
For every layer of 150 mm of compacted depth / based on the results of compaction trials.
At least one group of three in - situ density tests for each 500 m2 or fraction thereof.
B. Steel Reinforcement
A. Bar reinforcement for concrete for every 10,000 kg or fraction thereof for each size:
1 - Q, Quality Test for Bending, Tension and Chemical Analysis
1 - Q, Quality Test
C. Concrete
1~5
A. Cement
Quantity: (40 kg I bag)
Class A 9.0 bags I m3 of concrete
Class B 8.0 bags I m3 of concrete
Class C 9.5 bags I m3 of concrete
Class P 11.0 bags I m3 of concrete
B. Fine Aggregate
Quantity: m3 I m3 of concrete
For Rounded For Angular
Class A 0.50 0.54
Class B 0.45 0.52
Class C 0.53 0.59
Class P 0.44 0.47
C. Coarse Aggregates
Quantity: . m3 I m3 of concrete
For Rounded CA For Angular CA
Class A 0.77 0.68
Class B 0.82 0.73
Class C 0.70 0.68
Class P 0.68 0.65
H. Concrete
Tests: Compressive strength test on concrete cylinder samples. 1 set consisting of 3 concrete
cylinder samples shall be taken from each day's pouring and to rerresent not more tholn 75 m3 cf
concrete or fraction thereof.
136
PART H - MISCELLANEOUS STRUCTURES
Tests:
a. Cement
1 - Q, Quality Test
b. Fine Aggregate
Quantity: m3 / m3 of concrete
1 - G, Grading Test
c. Coarse Aggregates
Quantity: m3 / m3 of concrete
Tests:
1 - Q, Quality Test
b. Fine Aggregate
Quantity: m3 / m3 of concrete
1 - G, Grading Test
c. Coarse Aggregates
Quantity: m3 / m3 of concrete
138
Item 602 - Monuments, Markers and Guide Posts
A. Concrete
a. Cement
1 - Q, Quality Test
b. Fine Aggregate
Quantity: m3 / m3 of concrete
For Rounded For Angular
Class A - - - - - - - - .. .. 0.50 0.54
Class B - - - - - - - - .. .. 0.45 0.52
Class C ---------- 0.53 0.59
Class P ---------- 0.44 0.47
1 - G, Grading Test
c. Coarse Aggregates
Quantity: m3 I m3 of concrete
1 - G, Grading Test
d. Water
Tests: 1 - Q, Quality Test, if source is questionable
Tests:
a. Bar reinforcement for concrete for every 10,000 kg or fraction thereof for each size:
1 - Q, Quality Test for Bending, Tension and Chemical Analysis
b. Wire and Wire Mesh
1 - Q, Quality Test
139
C. Timber
D. Paint
Tests:
C. Concrete
Tests:
a. Cement
1 - Q, Quality Test
b. Fine Aggregate
Quantity: m3 / m 3 of concrete
1 - G, Grading Test
c. Coarse Aggregates
Quantity: m3 I m3 of concrete
1 - G, Grading Test
d. Water
Tests: 1 - Q, Quality Test, if source is questionable
140
e. Premolded Filler for expansion jOints
Tests: 1 - Q, Quality Test on each thickness of filler for each shipment
f. Steel Reinforcement
Tests: 1 - Q, Quality Test for every 10,000 kg or fraction thereof for each size
g. Concrete
Tests: Compressive strength test on concrete cylinder samples. 1 set consisting of ::I concrete
cylinder samples shall be taken from each day's pouring and to represent not more than 15 m J of
concrete or fr~ction thereof.
D. Reinforcing Steel
Tests: 1 - Q, Quality Test for every 10,000 kg or fraction thereof for each size
E. Rail
F. Paint
Tests:
1 ~ Q, One 20 - L can for every 100 cans or fraction thereof or
1 - Q, One 4 - L can for every 100 cans or fraction thereof
B. Concrete Post
a. Cement
1 - Q, Quality Test
b. Fine Aggregate
Quantity: m3 I m3 of concrete
1 - G, Grading Test
c. Coarse Aggregates'
Quantity: . m3 I m3 of concrete
141
For every 75 m3 or fraction thereof:
1 - G, Grading Test
d. Water
Tests: 1-Q, Quality Test, if source is questionable
Certificate of Project Engineer
e. Premolded Filler for expansion jOints
Tests: 1 - Q, Quality Test on each thickness of filler for each shipment
f. Steel Reinforcement
Tests:
A. Bar reinforcement for concrete for every 10,000 kg or fraction thereof for each size:
1 - Q, Quality Test for Bending, Tension and Chemical Analysis
B. Wire and Wire Mesh
1 - Q, Quality Test
g. Concrete
Tests: Compressive strength test on concrete cylinder samples. 1 set consisting of 3 concrete
cylinder samples shall be taken from each day's pouring and to represent not more than 75 m3 of
concrete or fraction thereof.
B. Fine Aggregate
Quantity: m3 I m3 of concrete
For Rounded For Angular
Class A 0.50 0.54
Class B 0.45 0.52
Class C 0.53 0.59
Class P 0.44 0.47
142
1 - G, Grading Test
Quantity: m 3 I m3 of concrete
Tests:
A. Bar reinforcement for concrete for every 10,000 kg or fraction thereof for each size:
1 - Q, Quality Test for Bending, Tension and Chemical Analysis
B. Wire and Wire Mesh
1 - Q, Quality Test
G. Concrete
Tests: Compressive strength test on concrete cylinder samples. 1 set consisting of 3 concrete
cylinder samples shall be taken from each day's pouring and to represent not more than 75 m 3 of
concrete or fraction thereof.
Tests:
143
a. Cement
Quantity: (40 kg / bag)
Class A --------- 9.0 bags / m 3 of concrete
Class B --------- 8.0 bags I m3 of concrete
Class C --------- 9.5 bags I m3 of concrete
Class P --------- 11.0 bags / m 3 of concrete
Tests: For every 2000 bags or fraction thereof
1- Q Quality Test
Concrete Pipes
Tests:
1 - Pipe for every 50 pieces: Strength, Absorption and Dimension
Alternative Requirement:
1 - set consisting of 3 concrete cylinder samples for not more than 25 pipes cast in the field
and
1 - Inspection Report for each size for not more than 25 pipes cast in the field
1 - G, Grading Test
c. Coarse Aggregates
Quantity: m 3 I m3 of concrete
For Rounded CA
Class A
-_ ...... __ .... _- 0.77
Class B .. .. .. .. .. .. .. .. .. .. 0.82
Class P .. .. .. .. .. .. .. .. .. .. 0.68
d. Water
Tests: 1 - Q, Quality Test, if source is questionable
f. Steel Reinforcement
Tests:
• Bar reinforcement for concrete for every 10,000 kg or fraction thereof for each size
1 - Q, Quality Test
g. Concrete
Tests: Compressive strength test on concrete cylinder samples. 1 set consisting of 3 concrete
cylinder samples shall be taken from each day's pouring and to represent not more than 75 m 3 of
concrete or fraction thereof.
Guardrail
I. Steel Posts
Tests:
1 - Q, Quality Test or Mill Test Certificate for each type of materials used
1 - Inspection Report for each type and shipment of metal used
II. Timber Posts
Tests: Inspection Report for Timber
III. Concrete
Tests:
a. Cement
145
Class P ---------- 11.0 bags I m3 of concrete
1 - Q, Quality Test
b. Fine Aggregate
Quantity: m 3 I m3 of concrete
1 - G, Grading Test
c. Coarse Aggregates
Quantity: m 3 I m3 of concrete
1 - G, Grading Test
d. Water
Tests: 1 - Q, Quality Test, if source is questionable
f. Steel Reinforcement .
Tests: 1 - Q, Quality Test for every 10,000 kg or fraction thereof for each size
g. Concrete
Tests: Compressive strength test on concrete cylinder samples. 1 set consisting of 3 concrete
cylinder samples shall be taken from each day's pouring and to represent not more than 75 m 3 of
concrete or fraction thereof.
C. Reinforcing Steel
Tests: 1 - Q, Quality Test for every 10,000 kg or fraction thereof for each size
D. Rail
Tests: Inspection Report
E. Paint
Tests:
1 - Q, One 20 - L can for every 100 cans or fraction thereof or
1 - Q, One 4 - L can for every 100 cans or fraction thereof
146
147