Vous êtes sur la page 1sur 2

MODEL: LCS4038A5B*

ALL ACCESSORIES OPTIONAL


38"
19"
ADA COMPLIANT

2012"

363 4"
39"
36"
A
SEE
OVER
40"
1"
A DETAIL D
3
TOP VIEW - SCALE 8" = 1'-0"

PERSPECTIVE VIEW - N.T.S.


Features:
1" -ADA compliant transfer shower
MODEL SHOWN HERE AS: 36"
-Available in various threshold heights
RIGHT REVEAL
-Molded, one piece gelcoat/fiberglass shower
RIGHT SEAT
module
LEFT PLUMBING
-"Classic Tile" wall finish, white (standard)
-Integral full wood backing for strength and
unlimited accessory placement
-"Reveal 90" front flange design allows for clear
floor space and transfer
-On all threshhold, heights 1-1/2" or taller,
763 4"

no mud set is required


Y

-On all threshold, heights 1-1/4" or shorter,no


mud set is required, but an epoxy adhesive kit
is supplied
*OTHER THRESHOLD HEIGHTS
AVAILABLE UPON REQUEST
UNIT THRESHOLD
HEIGHT HEIGHT
MODEL # Y Z*
LCS4038A5B 78-3/8" 5/8" MIN.
LCS4038A2B 79-3/4" 2" MAX.
Z
FRONT ELEVATION - SCALE: 38" = 1'-0" * - SEE BACK FOR DETAIL SECTIONS

PRODUCT SPECIFICATIONS:
-One piece shower module shall be constructed of gelcoat/fiberglass with full integral plywood backing
-Rough-In: Stud opening +1/4" -0" Nominal Dimensions.

C.S.I. FORMAT SPECIFICATION TEXT AVAILABLE

PRODUCT INFORMATION: ACCESSORIES: CODES:


-Accessories: Factory installed, unless prone to INSTALLED AT FACTORY: Designed and manufactured in compliance with
damage during installation/shipping. Polished -Grab bar the following standards and codes:
chrome/satin stainless standard, others available. -Seat, folding -A.N.S.I. Z124.2 Standards for Plastic Showers
-Colors: White as standard, others to match any -Mixing valve, pressure balanced, lever handle, -I.P.C. International Plumbing Code
major fixture manufacturer, also available with preplumbed tree to supply elbow -A.D.A. Accessibility Guildelines for Buildings and
sprayable solid surface in many colors -Vacuum breaker Facilities
-Custom curb heights, other than shown, are -Soap dish -A.N.S.I. A117.1 Accessible and Usable Buildings
available (between min. and max.) and Facilities
INSTALLED BY OTHERS: -U.P.C. Uniform Plumbing Code
-Curtain and rod
-Collapsible Rubber Water Retainer
-Semi-permanent Threshold Adaptor
-Caulkless drain

NOTICE OF LIMITATION:
-Recess as needed to meet code
-Adhere to floor as required
-Reveal not recommended on common wall

We reserve the right to make revisions without notice


in the design of fixtures or in packaging unless this
right has specifically been waived at the time the order
DIV. OF FIBERGLASS SYSTEMS INC. is accepted.
www.best-bath.com 1-800-727-9907 page 1 of 2
LCS4038A5B
SEMI-PERMANENT THRESHOLD ADAPTOR (OPTIONAL)
VINYL FLOORING
T-SHAPED RUBBER WATER STOPPER (OPTIONAL)
INTEGRAL LEVEL SUPPORT (ADHERED BY OTHERS)

212"
13 8"
1 "
2 4"
8" DIA. DRAIN CUT-OUT

5 "
8

SECTION A-A - SCALE: 3" = 1'-0"

LCS4038A2B
SEMI-PERMANENT THRESHOLD ADAPTOR (OPTIONAL)
BUILD UP OR RECESS
TO MEET CODE T-SHAPED RUBBER WATER STOPPER (OPTIONAL)

21 2"
13 8"
1 "
2
2"

SECTION A-A - SCALE: 3" = 1'-0"

**OTHER THRESHOLD HEIGHTS AVAILABLE UPON REQUEST**

STRAIGHT NAILING FLANGE


PLYWOOD FLANGE
GELCOAT APPROX. 1/8" THICK
FINISH WHERE USED STUD
(COLOR)

BARRIER
COAT

FIBERGLASS 5/8" GYP.


2" BRD.
SKIN
LAMINATE

FIBERGLASS
LAMINATE 1/2" MIN. ISOMETRIC
REVEAL FLANGE
WHERE USED

DETAIL B - SCALE: 3" = 1'-0" DETAIL C - SCALE: NTS DETAIL D - SCALE: 3" = 1'-0"
WALL SECTION DETAIL TYPICAL FRAMING REVEAL DETAIL

DIV. OF FIBERGLASS SYSTEMS INC.


www.best-bath.com 1-800-727-9907

page 2 of 2