Vous êtes sur la page 1sur 19

BUS IDE

IDE = Integrated Drive Electronis.

Denominación: 40 PIN IDC Macho.


40 PIN IDC Hembra.

En el disco y controlador (Macho)

En el Cable (Hembra)

Pin Name Dir Description


1 /RESET Reset
2 GND Ground
3 DD7 Data 7
4 DD8 Data 8
5 DD6 Data 6
6 DD9 Data 9
7 DD5 Data 5
8 DD10 Data 10
9 DD4 Data 4
10 DD11 Data 11
11 DD3 Data 3
12 DD12 Data 12
13 DD2 Data 2
14 DD13 Data 13
15 DD1 Data 1
16 DD14 Data 14
17 DD0 Data 0
18 DD15 Data 15
19 GND Ground
20 KEY - Key
21 n/c - Not connected
22 GND Ground
23 /IOW Write Strobe
24 GND Ground
25 /IOR Read Strobe
26 GND Ground
27 IO_CH_RDY
28 ALE Address Latch Enable
29 n/c - Not connected
30 GND Ground
31 IRQR Interrupt Request
32 /IOCS16 ? IO ChipSelect 16
33 DA1 Address 1
34 n/c - Not connected
35 DA0 Address 0
36 DA2 Address 2
37 /IDE_CS0 (1F0-1F7)
38 /IDE_CS1 (3F6-3F7)
39 /ACTIVE Led driver
40 GND Ground
SCSI

SCSI=Small Computer System Interface.

CENTRONICS 50

Denominación: 50 PIN CENTRONICS Hembra.


50 PIN CENTRONICS Macho.

Lado del Controlador y Dispositivos


(Hembra)

Lado del Cable (Macho)

SINGLE-
ENDED
Nº de Pin Nombre Dir Descripción
1-25 GND Ground
26 DB0 Data Bus 0
27 DB1 Data Bus 1
28 DB2 Data Bus 2
29 DB3 Data Bus 3
30 DB4 Data Bus 4
31 DB5 Data Bus 5
32 DB6 Data Bus 6
33 DB7 Data Bus 7
34 PARITY Data Parity (odd Parity)
35 GND Ground
36 GND Ground
37 GND Ground
38 TMPWR Termination Power
39 GND Ground
40 GND Ground
41 /ATN Attention
42 n/c - Not connected
43 /BSY Busy
44 /ACK Acknowledge
45 /RST Reset
46 /MSG Message
47 /SEL Select
48 /C/D Control/Data
49 /REQ Request
50 /I/O Input/Output

DIFERENCIAL

Nº de Pin Nombre Dir Descripción


01 GND Ground
02 +DB0 +Data Bus 0
03 +DB1 +Data Bus 1
04 +DB2 +Data Bus 2
05 +DB3 +Data Bus 3
06 +DB4 +Data Bus 4
07 +DB5 +Data Bus 5
08 +DB6 +Data Bus 6
09 +DB7 +Data Bus 7
10 +DBP +Data Bus Parity (odd Parity)
11 DIFFSENS ? ???
12 res - Reserved
13 TERMPWR Termination Power
14 res - Reserved
15 +ATN +Attention
16 GND Ground
17 +BSY +Bus is busy
18 +ACK +Acknowledge
19 +RST +Reset
20 +MSG +Message
21 +SEL +Select
22 +C/D +Control or Data
23 +REQ +Request
24 +I/O +In/Out
25 GND Ground
26 GND Ground
27 -DB0 -Data Bus 0
28 -DB1 -Data Bus 1
29 -DB2 -Data Bus 2
30 -DB3 -Data Bus 3
31 -DB4 -Data Bus 4
32 -DB5 -Data Bus 5
33 -DB6 -Data Bus 6
34 -DB7 -Data Bus Parity7
35 -DBP -Data Bus Parity (odd Parity)
36 GND Ground
37 res - Reserved
38 TERMPWR Termination Power
39 res - Reserved
40 -ATN -Attention
41 GND Ground
42 -BSY -Bus is busy
43 -ACK -Acknowledge
44 -RST -Reset
45 -MSG -Message
46 -SEL -Select
47 -C/D -Control or Data
48 -REQ -Request
49 -I/O -In/Out
50 GND Ground
D-SUB 25

Denominación: 25 PIN D-SUB Hembra.


25 PIN D-SUB Macho.

Lado del Controlador (Hembra)

Lado del Cable (Macho)

Pin Name Dir Description


1 /REQ Request
2 /MSG Message
3 I/O Input/Output
4 /RST Reset
5 /ACK Acknowledge
6 BSY Busy
7 GND Ground
8 DB0 Data Bus 0
9 GND Ground
10 DB3 Data Bus 3
11 DB5 Data Bus 5
12 DB6 Data Bus 6
13 DB7 Data Bus 7
14 GND Ground
15 C/D Control/Data
16 GND Ground
17 /ATN Attention
18 GND Ground
19 /SEL Select
20 PARITY Data Parity
21 DB1 Data Bus 1
22 DB2 Data Bus 2
23 DB4 Data Bus 4
24 GND Ground
25 TMPWR Termination Power

INTERNO

Denominación: 50 PIN IDC Hembra.


50 PIN IDC Macho.

Lado del Controlador y Discos (Macho)

Lado del Cable (Hembra)

DIFERENCIAL

Pin Name Dir Description


01 GND Ground
02 GND Ground
03 +DB0 +Data Bus 0
04 -DB0 -Data Bus 0
05 +DB1 +Data Bus 1
06 -DB1 -Data Bus 1
07 +DB2 +Data Bus 2
08 -DB2 -Data Bus 2
09 +DB3 +Data Bus 3
10 -DB3 -Data Bus 3
11 +DB4 +Data Bus 4
12 -DB4 -Data Bus 4
13 +DB5 +Data Bus 5
14 -DB5 -Data Bus 5
15 +DB6 +Data Bus 6
16 -DB6 -Data Bus 6
17 +DB7 +Data Bus 7
18 -DB7 -Data Bus Parity7
19 +DBP +Data Bus Parity (odd Parity)
20 -DBP -Data Bus Parity (odd Parity)
21 DIFFSENS ? ???
22 GND Ground
23 res - Reserved
24 res - Reserved
25 TERMPWR Termination Power
26 TERMPWR Termination Power
27 res - Reserved
28 res - Reserved
29 +ATN +Attention
30 -ATN -Attention
31 GND Ground
32 GND Ground
33 +BSY +Bus is busy
34 -BSY -Bus is busy
35 +ACK +Acknowledge
36 -ACK -Acknowledge
37 +RST +Reset
38 -RST -Reset
39 +MSG +Message
40 -MSG -Message
41 +SEL +Select
42 -SEL -Select
43 +C/D +Control or Data
44 -C/D -Control or Data
45 +REQ +Request
46 -REQ -Request
47 +I/O +In/Out
48 -I/O -In/Out
49 GND Ground
50 GND Ground

SINGLE-ENDED

Pin Name Dir Description


2 DB0 Data Bus 0
4 DB1 Data Bus 1
6 DB2 Data Bus 2
8 DB3 Data Bus 3
10 DB4 Data Bus 4
12 DB5 Data Bus 5
14 DB6 Data Bus 6
16 DB7 Data Bus 7
18 PARITY Data Parity (odd Parity)
20 GND Ground
22 GND Ground
24 GND Ground
26 TMPWR Termination Power
28 GND Ground
30 GND Ground
32 /ATN Attention
34 GND Ground
36 /BSY Busy
38 /ACK Acknowledge
40 /RST Reset
42 /MSG Message
44 /SEL Select
46 /C/D Control/Data
48 /REQ Request
50 /I/O Input/Output
SCSI II

Denominación: 50 PIN HI-DENSITY D-SUB Hembra.


50 PIN HI-DENSITY D-SUB Macho.

Lado del Controlador y Dispositivos (Hembra)

Lado del Cable (Macho)

SINGLE-
ENDED
Nº de Pin Nombre Dir Descripción
1-25 GND Ground
26 DB0 Data Bus 0
27 DB1 Data Bus 1
28 DB2 Data Bus 2
29 DB3 Data Bus 3
30 DB4 Data Bus 4
31 DB5 Data Bus 5
32 DB6 Data Bus 6
33 DB7 Data Bus 7
34 PARITY Data Parity (odd Parity)
35 GND Ground
36 GND Ground
37 GND Ground
38 TMPWR Termination Power
39 GND Ground
40 GND Ground
41 /ATN Attention
42 n/c - Not connected
43 /BSY Busy
44 /ACK Acknowledge
45 /RST Reset
46 /MSG Message
47 /SEL Select
48 /C/D Control/Data
49 /REQ Request
50 /I/O Input/Output

DIFERENCIAL

Nº de Pin Nombre Dir Descripción


01 GND Ground
02 +DB0 +Data Bus 0
03 +DB1 +Data Bus 1
04 +DB2 +Data Bus 2
05 +DB3 +Data Bus 3
06 +DB4 +Data Bus 4
07 +DB5 +Data Bus 5
08 +DB6 +Data Bus 6
09 +DB7 +Data Bus 7
10 +DBP +Data Bus Parity (odd Parity)
11 DIFFSENS ? ???
12 res - Reserved
13 TERMPWR Termination Power
14 res - Reserved
15 +ATN +Attention
16 GND Ground
17 +BSY +Bus is busy
18 +ACK +Acknowledge
19 +RST +Reset
20 +MSG +Message
21 +SEL +Select
22 +C/D +Control or Data
23 +REQ +Request
24 +I/O +In/Out
25 GND Ground
26 GND Ground
27 -DB0 -Data Bus 0
28 -DB1 -Data Bus 1
29 -DB2 -Data Bus 2
30 -DB3 -Data Bus 3
31 -DB4 -Data Bus 4
32 -DB5 -Data Bus 5
33 -DB6 -Data Bus 6
34 -DB7 -Data Bus Parity7
35 -DBP -Data Bus Parity (odd Parity)
36 GND Ground
37 res - Reserved
38 TERMPWR Termination Power
39 res - Reserved
40 -ATN -Attention
41 GND Ground
42 -BSY -Bus is busy
43 -ACK -Acknowledge
44 -RST -Reset
45 -MSG -Message
46 -SEL -Select
47 -C/D -Control or Data
48 -REQ -Request
49 -I/O -In/Out
50 GND Ground
SCSI III

Denominación: 68 PIN HI-DENSITY D-SUB Hembra.


68 PIN HI-DENSITY D-SUB Macho.

Lado del Controlador y Dispositivos (Hembra)

Lado del Cable (Macho)

SINGLE-ENDED

Pin Name Dir Description


1-16 GND Ground
17 TERMPWR Termination Power
18 TERMPWR Termination Power
19 res reserved
20-34 GND Ground
35 DB12 Data Bus 12
36 DB13 Data Bus 13
37 DB14 Data Bus 14
38 DB15 Data Bus 15
39 DPB1 Data Parity (odd Parity)
40 DB0 Data Bus 0
41 DB1 Data Bus 1
42 DB2 Data Bus 2
43 DB3 Data Bus 3
44 DB4 Data Bus 4
45 DB5 Data Bus 5
46 DB6 Data Bus 6
47 DB7 Data Bus 7
48 DPB Data Parity (odd Parity)
49 GND Ground
50 GND Ground
51 TERMPWR Termination Power
52 TERMPWR Termination Power
53 res reserved
54 GND Ground
55 /ATN Attention
56 GND Ground
57 /BSY Busy
58 /ACK Acknowledge
59 /RST Reset
60 /MSG Message
61 /SEL Select
62 /C/D Control/Data
63 /REQ Request
64 /I/O Input/Output
65 DB8 Data Bus 8
66 DB9 Data Bus 9
67 DB10 Data Bus 10
68 DB11 Data Bus 11

DIFERENCIAL

Pin Name Dir Description


1 +DB12 Data Bus 12
2 +DB13 Data Bus 13
3 +DB14 Data Bus 14
4 +DB15 Data Bus 15
5 +DPB1 Data Parity (odd Parity)
6 GND Ground
7 +DB0 Data Bus 0
8 +DB1 Data Bus 1
9 +DB2 Data Bus 2
10 +DB3 Data Bus 3
11 +DB4 Data Bus 4
12 +DB5 Data Bus 5
13 +DB6 Data Bus 6
14 +DB7 Data Bus 7
15 +DPB Data Parity (odd Parity)
16 DIFFSENSE ? Diff Sense?
17 TERMPWR Termination Power
18 TERMPWR Termination Power
19 res reserved
20 +ATN Attention
21 GND Ground
22 +BSY Busy
23 +ACK Acknowledge
24 +RST Reset
25 +MSG Message
26 +SEL Select
27 +C/D Control/Data
28 +REQ Request
29 +I/O Input/Output
30 GND Ground
31 +DB8 Data Bus 8
32 +DB9 Data Bus 9
33 +DB10 Data Bus 10
34 +DB11 Data Bus 11
35 -DB12 Data Bus 12
36 -DB13 Data Bus 13
37 -DB14 Data Bus 14
38 -DB15 Data Bus 15
39 -DPB1 Data Parity (odd Parity)
40 GND Ground
41 -DB0 Data Bus 0
42 -DB1 Data Bus 1
43 -DB2 Data Bus 2
44 -DB3 Data Bus 3
45 -DB4 Data Bus 4
46 -DB5 Data Bus 5
47 -DB6 Data Bus 6
48 -DB7 Data Bus 7
49 -DPB Data Parity (odd Parity)
50 GND Ground
51 TERMPWR Termination Power
52 TERMPWR Termination Power
53 res reserved
54 -ATN Attention
55 GND Ground
56 -BSY Busy
57 -ACK Acknowledge
58 -RST Reset
59 -MSG Message
60 -SEL Select
61 -C/D Control/Data
62 -REQ Request
63 -I/O Input/Output
64 GND Ground
65 -DB8 Data Bus 8
66 -DB9 Data Bus 9
67 -DB10 Data Bus 10
68 -DB11 Data Bus 11
UNIDAD 3.5"

Denominación: 34 PIN IDC Macho.


34 PIN IDC Hembra.

Lado de la Unidad y la Placa (Macho)

En el Cable (Hembra)

Pin Name Dir Description


2 /REDWC Density Select
4 n/c Reserved
6 n/c Reserved
8 /INDEX Index
10 /MOTEA Motor Enable A
12 /DRVSB Drive Sel B
14 /DRVSA Drive Sel A
16 /MOTEB Motor Enable B
18 /DIR Direction
20 /STEP Step
22 /WDATE Write Data
24 /WGATE Floppy Write Enable
26 /TRK00 Track 0
28 /WPT Write Protect
30 /RDATA Read Data
32 /SIDE1 Head Select
34 /DSKCHG Disk Change
La interfaz Serial-ATA

Tabla 2 Nomenclatura:
HT+, HT-. Par de señales
Pin Designación diferenciales de transmisión del lado
del host ("Host Transmitter").
S1 G. HR+, HR- Ídem de recepción ("Host
Receiver").
S2 HT+ / DR+ DT+ y DT- par de señales
diferenciales de transmisión del lado
S3 HT- / DR- del dispositivo ("Device Transmitter").
DR+, DR-. Ídem de recepción
S4 G. ("Device Receiver").
G. Tierra ("Ground").
S5 HR+ / DT+
Como es de esperar, las señales de
S6 HR- / DT- transmisión del adaptador host se
corresponden con las de recepción
S7 G. del dispositivo y viceversa

Vous aimerez peut-être aussi