Académique Documents
Professionnel Documents
Culture Documents
NEW FEATURES!
• Longer Reflectorless Range
• Dual-Axis Compensated
• Absolute Encoding
Professional Performance
at an Affordable Price
• 2-Second and 5-Second accuracy available
• Working range up to 9,840-ft (3000m)
with single prism
• 984-ft (300m) working range without prism
• Dual-Axis Compensated
• Absolute Encoding
Proven Simplicity
• Easy to target collimator
• Nearly unlimited storage with built in SD Card
• USB and RS-232 interface
www.cstberger.com
CST-300R Series
ELECTRONIC REFLECTORLESS
2 TOTAL STATION
Superior Optics
(30x Magnification)
Data upload and
data-transfer
through RS-232
Easy-to-target data or USB port
collimator
IDEAL FOR:
Surveying and Construction
Alpha/numeric
keypad
Product Specifications
Telescope Image Erect Communication USB / RS-232
Magnification 30x Vertical Compensator System Dual-Axix / Opto-Electrical /
Compensated
Effective Aperture 45mm
Compensation Range ±4’
Resolving Power 3”
Resolving Power 1”
Field of View 1°30’
Optical Plummet Image Erect
Minimum Focus 1.3m
Magnification 3x
Tube Length 152mm
Focusing Range 0.3mm~infinity
Angle Measurement Measuring Method Absolute Encoding
Field of View 5°
Dia. of Circle (V/H) 79mm
Display Type No
Minimum Reading 1-5” Selectable
Power On-Board Battery Rechargeable NiMH
Detection Method Horizontal: Dual Power Source (56-NMHCST300)
Vertical: Dual
Voltage DC6V
Measuring Unit 360°/400gon/6400mil Selectable
Continuous Operation Time 5-6 Hours
Accuracy CST302R 2”
CST305R 5” Operation Environment Operating Temperature -20°C to +45°C
Distance Measurement Reflectorless Range 984-ft (300m) Size and Weight Dimension 160 x 150 x 340 mm
Single Prism 9,840-ft (3.0km) Weight 5.4kg
(Under fair weather conditions)
Note:
Triple Prism 15,026-ft (4.5km) *The measurement range may vary by measurement conditions.
(Under fair weather conditions) -Average conditions: 65,616-ft (20km) visibility with slight shimmer.
-Good conditions: 131,233-ft (40km) visibility, overcast, no heat, no shimmer and moderate wind.
Unit m/ft *EDM Measuring time varies according to distance to be measured and conditons of the environment.
Accuracy ±(2mm + 2ppm x D)
Measuring TIme Fine Single Shot: 1.8S 56-CST302R 2-Second Reflectorless Total Station
Tracking: 0.7S 56-CST305R 5-Second Reflectorless Total Station
Vial Plate Vial 30”/2mm Standard Configuration Includes: Battery Pack (2), Battery
Charger, Plumb Bob, Set of Tools, Carrying Case, Software
Circular Vial 8’/2mm
and Cable, Instruction Manual