TOSHIBA 1450 TB 1

General Information Substitute replacement components which do 2. Ajust HEIGHT Control (R351) so that white CUT OFF Controls to obtain a good white
not have the same safety characteristics as blocks at top and bottom of the picture are are balance in both low and high light areas.
specified in the parts list may create X-ray just masked.
Chassis : C4E-R radiation SUB-BRIGHTNESS ADJUSTMENT
Also Covers 1450 RB HORIZONTAL CENTRE ADJUSTMENT
Service Adjustments 1. Tune in a colour programme of Philips
1. Receive the UK PHILIPS pattern. pattern.
fragments. Use shatter proof goggles and GENERAL INFORMATION 2. Set the contrast and colour to centre, and the 2. Set the CONTRAST Control to the minimum
and the BRIGHTNESS Control to the centre.
Safety Instructions take extreme care while handling. Do not hold
All adjustments are thoroughly checked and
brightness to centre.
3. Set the COLOUR Control to the minimum.
Example of screen display in level adjustment
the C.R.T. by the neck as this is a very 3. Adjust H. CENTER USER Control (R451) so
X-RAY RADIATION PRECAUTION dangerous practice. corrected when the receiver leaves the factory. the pattern can be located for d-c to be + 4.0 mm. 4. Set the SUB-BRIGHT. Control (R551) so that PICTURE I-F ALIGNMENT
1. The E.H.T. must be checked every time the 2. It is essential that to maintain the safety of the Therefore the receiver should operate normally the voltage across terminals Y-Z can be 0.2 ±
receiver is serviced to ensure that the C.R.T. customer all cable forms be replaced exactly and produce proper colour and B/W pictures 0.05V with voltmeter and leave the receiver GENERAL
does not emit X-ray radiation as result of as supplied from factory. upon installation. However, several minor for five minutes in this state. Refer to figure 4 for test equipment connection.
excessive E.H.T. voltage. The nominal E.H.T. 3. A small part of the chassis used in this adjustments may be required depending on the 5. Watching the picture well, adjust the SUB-
for this receiver is 24.0 kV at zero beam receiver is, when operating, at approximately particular location in which the receiver is BRIGHT. Control in the position where the PRELIMINARY STEPS
current (minimum brightness) operating at half mains potential at all times. It is therefore operated. picture does not show evidence of blooming Supply +5 volts to the 5V-1 line.
240V a.c. The maximum E.H.T. voltage essential in the interest of safety that when This receiver is shipped completely in cardboard in high bright area and not appear too dark in
permissible in any operating circumstances serving or connecting any test equipment the carton. Carefully draw out the receiver from the low bright portion. SIGNAL GENERATOR
must not exceed 26.0 kV. When checking the receiver should be supplied via a suitable carton and remove all packing materials. Plug 6. Check the proper picture variation by rotating Connect to both leads of R101 with signal level
E.H.T., use the ‘High Voltage Check’ proce- isolating transformer of adequate rating. the power cord into a convenient 240 volts 50 FOCUS ADJUSTMENT the CONTRAST and BRIGHTNESS Controls of 75 dBµ, and open the solder-link at IF OUT of
dure in this manual using an accurate E.H.T. 4. Replace blown fuses within the receiver with Hz AC two pin power outlet. Turn the receiver to both extremes. tuner on the Main Board. (See figure 4.)
voltmeter. the fuse specified in the parts list. ON. Check and adjust all the customer controls Adjust FOCUS Control on FLYBACK TRANS. 7. If the picture does not appear dark with the
2. The only source of X-RAY radiation in this 5. When replacing wires or components to such as BRIGHTNESS, CONTRAST and (T461) for well defined scanning lines in the CONTRAST and BRIGHTNESS Controls DVM
receiver is the C.R.T. To prevent X-ray terminals or tags, wind the leads around the COLOUR Controls to obtain natural colour or B/ centre area on the screen. turned to the minimum, or not appear bright Connect to pin #44 of 1C501 on the Main Board
radiation, the replacement C.R.T. must be terminal before soldering. When replacing W picture. with the controls turned to the maximum, through the detector.
identical to the original fitted as specified in safety components identified by the interna- DELAYED R-F AGC ADJUSTMENT adjust the SUB-BRIGHT. Control again for the
the Parts List. tional hazard symbols on the circuit diagram AUTOMATIC DEGAUSSING acceptable picture.
3. Some components used in this receiver have and parts list, it must be a Toshiba approved 1. Tune the set to the strongest station in your
safety related characteristics preventing the type and must be mounted as the original. A degaussing coil is mounted around the picture area. BUS DATA SETTING
C.R.T. from emitting X-ray radiation. 6. Keep wires away from high temperature tube so that external degaussing after moving 2. Turn AGC DELAY Control (R151) on PIF
For continued safety, replacement component components. the receiver is normally unnecessary, providing Board to fully counterclockwise position. 1. In the TV set of initial lot of production,
should only be made after referring the the receiver is properly degaussed upon 3. Adjust AGC DELAY Control clockwise until SAA5290ZP/024 is used for QA01. But
Product Safety Notice. PRODUCT SAFETY NOTICE installation. The degaussing coil operates for noise (snow) disappears on the screen. replace with SAA5290ZP/032 for servicing.
Many electrical and mechanical components in about 1 second after the power to the receiver is 2. When QA01 only is replaced, it is not
SAFETY PRECAUTION this chassis have special safety-related switched ON. If the set is moved or faced in a CRT GREY SCALE ADJUSTMENT necessary to change the mode data.
1. This receiver has a nominal working E.H.T. characteristics. These characteristics are often different direction, the power switch must be 3. When memory IC (QA02) is replaced, change
voltage of 22.5 kV. Extreme caution should be passed unnoticed by a visual inspection and the switched off at least 30 minutes in order that the 1. Press VIDEO INPUT button on Remote the mode data in the manner below.
exercised when working on the receiver with X-ray radiation protection afforded by them automatic degaussing circuit operates properly. Control unit to turn TV to video input mode.
the back removed. cannot necessarily be obtained by using Should the chassis or parts of the cabinet Next press PICTURE SELECT button to Figure 4. Picture IF Alignment
Do not attempt to service this receiver if you replacements rated at higher voltages or become magnetized to cause poor colour purity, select function and set CONTRAST to ADJUSTMENT METHOD FOR SERVICING
are not conversant with the precautions and wattage, etc. Components which have these use an external degaussing coil. Slowly move minimum, BRIGHTNESS to maximum, STEP
procedures for working on high voltage special safety characteristics in this manual and the degaussing coil around the faceplate of the COLOUR to minimum. 1.OUTLINE Detector Coil
equipment. its supplements are identified by the interna- picture tube, the sides and front of the receiver 2. Turn the SCREEN Control (on T461) fuly In the service mode, MODE DATA adjustments
SIGNAL GENERATOR
When handling or working on the C.R.T., tional hazard symbols on the schematic diagram and slowly withdraw the coil to a distance of counterclockwise. can be made easily with user remote control
39.5 MHz CARRIER WAVE (Level 75 dBµ)
always discharge the anode to the receiver and parts list. Before replacing any of these about 2 m before disconnecting it from AC 3. Set the RED, GREEN and BLUE CUT OFF unit. (CT-9689 only)
chassis before removing the anode cap. components read the parts list carefully. source. If colour shading still persists, perform Controls (R557, R558, R559) ADJUST
The C.R.T., if broken, will violently expel glass the COLOUR PURITY ADJUSTMENT and counterclockwise to the centre position. 2.SERVICE MODE OPERATION T103
CONVERGENCE ADJUSTMENTS procedures. 4. Set the CUT OFF SW. (S202) in the H. line
2-1. How to Enter the Service Mode REMARKS
position. 1. Supply external DC power (+ 5V) to 5V-1 line.
HIGH VOLTAGE CHECK 5. Set the SUB BRIGHTNESS Control to 2. Supply + 8V to pin 36 of IC501.
Recommended Safety Parts minimum. 3. Supply external DC power to + 12V line.
CAUTION: There is no HIGH VOLTAGE 6. Rotate the SCREEN Control gradually 4. Apply test signal to IF input.
Item Part No. Description 5. Short pin 30 of ICA01 to ground.
ADJUSTMENT on this chassis. clockwise until the first horizontal line of a
A401 23425821 Back Cover 6. Open pin 30 of ICA01.
colour (RED, GREEN or BLUE) appears
C440 24082347 PF, 6700pF, ±3%, 1500V 7. Adjust T103 so that DC voltage at pin 44 of
C463 24212222 CD, 2200pF, ±10% 1. Connect an accurate high voltage meter to slightly on the screen. IC501 becomes 3.2V ± 0.5V.
C801 24082363 PF, 0.22pF, ±20%, AC250V the second anode of the picture tube.
C802 24094656 CD, 2200pF, ±20%, AC400V
Set the SCREEN Control to this position.
C803 24094656 CD, 2200pF, ±20%, AC400V 2. Turn on the receiver. Set the BRIGHTNESS 7. Adjust the CUT OFF Controls to obtain the After completing the above steps, disconnect
R327 24339569 MF, 5.6 ohm, 2W
and CONTRAST Controls to minimum (zero slightly lighted horizontal lines in the same the equipment and re-solder the links on the
R444 24338398 ME, 0.39 ohm, 1W
beam current). 2-2. How to Exit from the ServIce Mode Main Board, and adjust the AGC Delay control
R448 24338338 ME, 0.33 ohm, 1W levels of three colours (RED, GREEN and
R801 24009954 Metal-Glazed Resistor, 2.2M ohm, 1/2W (R151) following DELAYED RF AGC ADJUST-
R844 24005007 Metal-Glazed Resistor, 8.2M ohm, 1W
3. High voltage will be measured below 26.0 kV. BLUE). MENTS.
R890 24000918 PTC Thermistor, 18 ohm, ±20%, 290V 4. Change the BRIGHTNESS Control to both The lines may look like white if the CUT OFF Exit the service mode by turning the power on/
R920 24000884 FR, 3 ohm, 1W off with the remote control.
L462 ------------ DY, Supplied with V901
extremes to be sure the high voltage does not Controls are adjusted properly.
L901 23200691 Coil, Degaussing, TSB-2229AT exceed the limit of 26.0 kV under any 8. Return the CUT OFF SW. (S202) in the
T401 23224983 Transformer, Horiz. Drive, TLN1039
T461 23236501 Transformer, Flyback, TFB4124AE conditions. receiving position. 3. ADJUSTMENT IN THE SERVICE MODE
T801 23211929 Line Filter, TRF3130 9. Set the BRIGHTNESS Control to the maxi-
T803 23217274 Transformer, Converter,TPW3322AR
Q404 A6871242 Transistor, 2SD1554 HEIGHT ADJUSTMENT mum and COLOUR Control to the centre. Service Mode Level Adjustments
Q826 A8643108 Photo Coupler, TLP621(GR-LF 10.Set the BRIGHTNESS and CONTRAST 1) Push + key (simultaneous push) to
F801 23144898 Fuse, 3.15A
F803 23144876 Fuse, 0.5A 1. Receive the WG PHILIPS pattern, and set the Controls to obtain dark grey raster. Then appear Mode Data to be adjusted.
P801 23372012 Power Cord contrast and colour to minimum, and the check the white balance in low brightness. If 2) Adjust with the level UP/DOWN (VOL UP/
S801 23145434 Switch, Power, 2C2P
V901A 23902022 Socket, CRT, 8P brightness to centre. the white balance is not proper, retouch the DOWN) key.
V901 23312582 Picture Tube, A34EAC01X65

Safety Parts / Service Adjustments / Safety Instructions / Main Diagram / Main Diagram Cont’d
TOSHIBA 1450 TB 2
Main Diagram
TOSHIBA 1450 TB 3

Main Diagram Cont’d