Project Documentation

File: IPC-201C_202A_203_DECIMALES.project

Date: 29/12/2021

Profile: V19.2.3.0
Tabla de contenido

Tabla de contenido
1 Lista de variables globales: COPIA_VARIABLES 3
2 Lista de variables globales: GlobalVariables 3
3 Lista de variables globales: GVL 4
4 Lista de variables globales: LocalIo 4
5 Lista de variables globales: MemoryBit 5
6 Lista de variables globales: MemoryWord 5
7 Lista de variables globales: NVL_send 6
8 Lista de variables de red (receptor): NVL_receive_3 6

IPC-201C_202A_203_DECIMALES.project
Page 2 of 7
29/12/2021 20:54
1 Lista de variables globales: COPIA_VARIABLES

1 Lista de variables globales: COPIA_VARIABLES


1 {attribute 'qualified_only'}
2 VAR_GLOBAL
3 COPIA_IPC2_ON AT %MX40000.0 : BOOL ;
4 COPIA_IPC1_START_CYCLE AT %MX40000.1 : BOOL ;
5 COPIA_IPC1_DP1 AT %MX40000.2 : BOOL ;
6 COPIA_START_IPC3 AT %MX40000.3 : BOOL ;
7 COPIA_IPC3_ON AT %MX40000.4 : BOOL ;
8 COPIA_IPC3_CYCLE_END AT %MX40000.5 : BOOL ;
9 COPIA_IPC3_DP2 AT %MX40000.6 : BOOL ;
10 END_VAR
11

2 Lista de variables globales: GlobalVariables


1 VAR_GLOBAL
2 //Global status os IPC3_ON network variable
3 IPC3_ON_GLOBAL : BOOL ;
4 //Global status os IPC3_CYCLE_END network variable
5 IPC3_CYCLE_END_GLOBAL : BOOL ;
6 //Global status os IPC3_DP1 network variable
7 IPC3_DP2_GLOBAL : BOOL ;
8 TM0 : TES . FB_Timer ;
9 TM1 : TES . FB_Timer ;
10 TM10 : TES . FB_Timer ;
11 TM11 : TES . FB_Timer ;
12 TM12 : TES . FB_Timer ;
13 TM13 : TES . FB_Timer ;
14 TM15 : TES . FB_Timer ;
15 TM16 : TES . FB_Timer ;
16 TM17 : TES . FB_Timer ;
17 TM18 : TES . FB_Timer ;
18 TM19 : TES . FB_Timer ;
19 TM2 : TES . FB_Timer ;
20 TM20 : TES . FB_Timer ;
21 TM21 : TES . FB_Timer ;
22 TM22 : TES . FB_Timer ;
23 TM23 : TES . FB_Timer ;
24 TM24 : TES . FB_Timer ;
25 TM25 : TES . FB_Timer ;
26 TM5 : TES . FB_Timer ;
27 TM6 : TES . FB_Timer ;
28 TM7 : TES . FB_Timer ;
29 TM8 : TES . FB_Timer ;
30 TM9 : TES . FB_Timer ;
31 TM0_Preset : INT := 2 ;
32 TM1_Preset : INT := 2 ;
33 TM10_Preset : INT := 2 ;
34 TM11_Preset : INT := 2 ;
35 TM12_Preset : INT := 1 ;
36 TM13_Preset : INT := 3 ;
37 TM15_Preset : INT := 5 ;

IPC-201C_202A_203_DECIMALES.project
Page 3 of 7
29/12/2021 20:54
2 Lista de variables globales: GlobalVariables

38 TM16_Preset : INT := 5;
39 TM17_Preset : INT := 1;
40 TM18_Preset : INT := 2;
41 TM19_Preset : INT := 6;
42 TM2_Preset : INT := 2;
43 TM20_Preset : INT := 25 ;
44 TM21_Preset : INT := 5;
45 TM22_Preset : INT := 1;
46 TM23_Preset : INT := 2;
47 TM24_Preset : INT := 3;
48 TM25_Preset : INT := 1;
49 TM5_Preset : INT := 55 ;
50 TM6_Preset : INT := 15 ;
51 TM7_Preset : INT := 1;
52 TM8_Preset : INT := 1;
53 TM9_Preset : INT := 1;
54 END_VAR
55

3 Lista de variables globales: GVL


1 VAR_GLOBAL
2 END_VAR
3

4 Lista de variables globales: LocalIo


1 VAR_GLOBAL
2 // Start push button
3 START_BUTTON : BOOL ;
4 // Stop push button
5 STOP_BUTTON : BOOL ;
6 // Auto / Manual mode selector
7 AUTOMAN : BOOL ;
8 // Reset push button
9 RESET_BUTTON : BOOL ;
10 // Index plate pusher back
11 A0 : BOOL ;
12 // Unloading manipulator up
13 C0 : BOOL ;
14 // Unloading manipulator down
15 C1 : BOOL ;
16 // Unloading manipulator back
17 D0 : BOOL ;
18 // Unloading manipulator fore
19 D1 : BOOL ;
20 // Unloading gripper closed
21 E1 : BOOL ;
22 // Cover feeder back
23 F0 : BOOL ;
24 // Cover feeder fore
25 F1 : BOOL ;
26 // Cover pressing cylinder up
27 G0 : BOOL ;

IPC-201C_202A_203_DECIMALES.project
Page 4 of 7
29/12/2021 20:54
4 Lista de variables globales: LocalIo

28 // Cover pressing cylinder down


29 G1 : BOOL ;
30 // Can presence in water filling position
31 DP1 : BOOL ;
32 // Red light lamp
33 BR : BOOL ;
34 // Index plate pusher forwards
35 A_FOR : BOOL ;
36 // Index plate locking cylinders forwards
37 B_FOR : BOOL ;
38 // Unloading manipulator downwards
39 C_DOWN : BOOL ;
40 // Unloading manipulator forwards
41 D_FOR : BOOL ;
42 // Unloading gripper closure
43 E_CLOSE : BOOL ;
44 // Cover feeding downward cylinder forwards
45 F_FOR : BOOL ;
46 // Cover pressing cylinder downwards
47 G_DOWN : BOOL ;
48 // Can feeding cylinders forwards
49 H_FOR : BOOL ;
50 // Can filling valve opening
51 A4_OPEN : BOOL ;
52 // Cover feeding upward cylinder forwards
53 I_FOR : BOOL ;
54 END_VAR
55

5 Lista de variables globales: MemoryBit


1 VAR_GLOBAL
2 // Can presence at Station 3
3 CAN_AT_IPC203 AT %MX20004.5 : BOOL ;
4 // Continue program sequence
5 CONTINUE_ AT %MX20004.6 : BOOL ;
6 // Automatic mode of the station
7 AUTO AT %MX20004.7 : BOOL ;
8 // Initial conditions of the station
9 INITIAL_CONDITIONS AT %MX20005.0 : BOOL ;
10 // Properly positioned can verification
11 CHECK_OK AT %MX20005.1 : BOOL ;
12 // Unloading cycle done indication
13 UNLOADING_CYCLE AT %MX20005.2 : BOOL ;
14 END_VAR
15

IPC-201C_202A_203_DECIMALES.project
Page 5 of 7
29/12/2021 20:54
6 Lista de variables globales: MemoryWord

6 Lista de variables globales: MemoryWord


1 VAR_GLOBAL
2 // Can at loaading position
3 LOAD_CAN AT %MX12.0 : BOOL ;
4 // Can at filling position
5 FILL_CAN AT %MX12.1 : BOOL ;
6 // Can at cover feeding position
7 FEED_COVER_CAN AT %MX12.2 : BOOL ;
8 // Can at cover pressing position
9 PRESS_CAN AT %MX12.3 : BOOL ;
10 // Can at unloading position
11 UNLOAD_CAN AT %MX12.4 : BOOL ;
12 // Start from the SCADA // PC --> PLC
13 START_SCADA AT %MX22.0 : BOOL ;
14 // Stop from the SCADA // PC --> PLC
15 STOP_SCADA AT %MX22.1 : BOOL ;
16 // Auto/Man from the SCADA // PC --> PLC
17 AUTOMAN_SCADA AT %MX22.2 : BOOL ;
18 // Reset from the SCADA // PC --> PLC
19 RESET_SCADA AT %MX22.3 : BOOL ;
20 // Output channel 0 to SCADA // PLC --> PC
21 OUTPUT_CHANNEL_0 AT %MW20 : INT ;
22 // Output channel 1 to SCADA // PLC --> PC
23 OUTPUT_CHANNEL_1 AT %MW21 : INT ;
24 // Output channel 2 to SCADA // PLC --> PC
25 OUTPUT_CHANNEL_2 AT %MW22 : INT ;
26 // Output channel 3 to SCADA // PLC --> PC
27 OUTPUT_CHANNEL_3 AT %MW23 : INT ;
28 // Output channel 4 to SCADA // PLC --> PC
29 OUTPUT_CHANNEL_4 AT %MW24 : INT ;
30 // Output channel 5 to SCADA // PLC --> PC
31 OUTPUT_CHANNEL_5 AT %MW25 : INT ;
32 // Output channel 6 to SCADA // PLC --> PC
33 OUTPUT_CHANNEL_6 AT %MW26 : INT ;
34 // Output channel 7 to SCADA // PLC --> PC
35 OUTPUT_CHANNEL_7 AT %MW27 : INT ;
36 END_VAR
37

7 Lista de variables globales: NVL_send


1 VAR_GLOBAL
2 // IPC-202 on for IPC-203
3 IPC2_ON : BOOL ;
4 // Start cycle for IPC-201
5 IPC1_START_CYLE : BOOL ;
6 // Can presence for IPC-201
7 IPC1_DP1 : BOOL ;
8 // Start cycle for IPC-203
9 START_IPC3 : BOOL ;
10 END_VAR
11

IPC-201C_202A_203_DECIMALES.project
Page 6 of 7
29/12/2021 20:54
8 Lista de variables de red (receptor): NVL_receive_3

8 Lista de variables de red (receptor): NVL_receive_3


1 //This gobal variable list is received via the network.
2 //Sender: NVL_send [IPC203: PLC Logic: Application]
3 //Protocol: UDP
4
5 VAR_GLOBAL
6 // IPC203 active to station IPC202
7 IPC3_ON : BOOL ;
8 // End cycle of IPC203 to IPC202
9 IPC3_CYCLE_END : BOOL ;
10 // Can presence at IPC203 to IPC202
11 IPC3_DP2 : BOOL ;
12 END_VAR
13

IPC-201C_202A_203_DECIMALES.project
Page 7 of 7
29/12/2021 20:54