Vous êtes sur la page 1sur 1

Nairobi Block 94/327 TO GACHIE SHOPPING CENTRE (ABOUT 500m FROM JUNCTION) TO UNEP JUNCTION (ABOUT 2KM) GENERAL

TO GACHIE SHOPPING CENTRE (ABOUT 500m FROM JUNCTION) TO UNEP JUNCTION (ABOUT 2KM) GENERAL NOTES
68,260 Nairobi Block 94/236 1.01 All work to be carried out in accordance with local

r v e
3,700 835 7,050 2,915 3,600 225 3,600 3,600 3,600 3,600 3,600 225 3,600 3,600 3,600 3,600 3,600 3,600 3,600 3,600 3,045 Nyari
Nairobi Block 94/237 Police council regulations.

2,400
p.v
Laundry
Post 1.02 All figure dimensions to be taken in preference to

e
2,475
g.t
NORTH DIRECTION
3,705
p.v
I.C s.v.p

00
p.v
p.v g.t I.C I.C

3,6

r v
p.v p.v
Screen wall to details scaled dimensions.
r e s e

Cook Area
p.v
p.v
Nairobi Block 94/206
p.v

Yard

7,550
1.03 All dimensions to be approved on site and setting

2,500
Laundry
Kitchen/Laundry Yard
p.v p.v p.v

e
Kitchen

00
Dining room
3,600

p.v
out approved by the Architect.

3,6
p.v
Screen wall

s
Fridge

p.v DSQ Room 1 DSQ Room 2 p.v


p.v

2,500
to details Kitchen Store
1.04 No trees to be cut down without the prior consent
p.v
p.v

r e
p.v
g.t
I.C
9,690

00
3,200 3,200 3,200 Nairobi Block 94/207 of the Architect.

3,6
3,600

I.C R 650 Soak pit I.C


4,500
1.05 Depth of foundation to be determined on site by
r o a d

d
Foyer
23,600

Port Cochere Living room structural Engineer (S.E.'s)

240 0
p.v
Terrace

28, 3,60
p.v

a
ceramic tiles floor finish

1.06 Provide 500g polythene dump proof membrane


7,400
3,600

r o
g.t
Nairobi Block 94/208
(DPM) under ground floor slabs.
p.v
I.C I.C Septic tank I.C I.C

00
2,100 I.C

3,6
s.v.p
150 1,800 150
I.C 1.07 Provide approved damp proof course (DPC)

e
R 1,250
w i d e

4,225

below all walls.


2,950

Guard g.t p.v Guest Bedroom shower


Mini Lounge p.v
Nairobi Block 94/318

00

i d
house Terrace
Nairobi Block 94/328

3,6
Bath
1.08 All walls below 200mm to be reinforced with whoop
R 1,200 p.v

iron at every alternate course.

w
p.v
p.v s.v.p Nairobi Block 94/319
Terrace

00
p.v g.t
3,635

3,600

1,100

3,6
Steel gate to details I.C I.C I.C 1.09 All reinforced concrete works to be in accordance
1,105

m
with S.E‘s details.

2,400

40
Nairobi Block 94/210
1 2 m

3,0
1.10 Permanent ventilation (PV) to be provided as

0
1,185 3,600 3,600 3,600 3,600 3,600 225 3,600 3,600 3,600 3,600 3,600 225 3,600 3,600 3,600 3,600 3,700 82,1
indicated in drawings.

80
6
40

26,4
55,920 SITE FOR THE
1.11 All sanitary installations to be in accordance with
SITE LAYOUT PLAN Nairobi Block 94/91 PROPOSED Nairobi Block 94/327
68,2
MOH regulations.

00
DEVELOPMENT 60

23,6
0
,76
31
Nairobi Block 94/328 1.12 All plumbing and drainage works to be carried out
0
,24
55,9
20 28
in accordance with M.E’s details.

300 750
750

1.13 All plumbing and drainage pipes to be sleeved


300x200mm ring
beam to S.E's details Nairobi Block 94/91 through walls.
1.14 All drainage passing under building and drive to be
UPVC encased in 150mm concrete surround.
1,500

200mm masonry 1.15 Provide heavy duty covers to all inspection

1,200
walling to details
chambers, ICs, in drives.
Cement render to SITE LOCATION PLAN (Scale 1: 1,750) 1.16 Water meters to be at least 300mm above the
concrete work to
details ground level.

d.o.s
Boundary Wall Part Elevation
200 3,400 200 3,400 200 200 3,400 200 3,400 200 FIRE NOTES

200
600
Sectional Elavation 2.01 Provide 1130 litres dedicated water storage
tank and a booster pump
2.02 Provide 1 No: hydraulic hosereel with spray/jet
Boundary Wall Part Plan nozzle on each floor
8mm O DISTR. BARS AT 200mm CENTRES
12mm O MAIN BARS AT 300mm CENTRES
2.03 Provide emegency lighting with independent
450X600mm MANHOLE 8mm O MAIN BAR AT
COVER AND FRAME 300mm C/C 450X600mm MANHOLE power supply
120

COVER AND FRAME


GL GL GL GL
2.04 Provide emergency EXIT sign on each floor
NUMBER
CAPACITY OF DIMENSIONS IN MILLIMETRES 2.05 Provide 1No: 9kg dry powder fire extinguisher
120

INLET MANHOLE
PERSONS at each hosereel point
350

OUTLET MANHOLE 150mm THK E GALLONS LITRES A B C D E F F2


C1 4 O INLET PIPE 10mm O MAIN BAR C1 4 O OUTLET PIPE
BLOCK WORK
450

300 1360 UPTO TO 10 400 300 1300 2200 700 900 1360
100

IL 600 2720 11-20 750 600 1350 2900 900 1100 2720
250

250

WATER LEVEL 900 4080 21-30 900 750 1350 3200 1100 1200 4080
150

TWL
1200 5440 31-40 900 850 1350 3300 1300 1300 5440

1500 6800 41-50 1000 950 1350 3500 1400 1400 6800
150

150

500
550

100mm THK CONCRETE


FOUNDATION MIX 1:3:6
A B C 200mm THK
BLOCK WORK

200mm THK Project title:


100
F2

BLOCK WORK
200mm THK
PROPOSED RESIDENTIAL HOUSE AT NYARI
1,400

BLOCK WORK

NOTES
12mm WATER PROOF
CEMENT -SAND RENDERING AREA ON PLOT No: NAIROBI BLOCK 94/328
12mm WATER PROOF CEMENT-
12mm WATER PROOF
CEMENT-SAND PLASTER
1. CONCRETE TO BE 1:2;3 3/4" GRADED AND TO BE ACCORDING FOR Mr. MAHMOOD MAWJI & Mrs. RAHEEL
SAND PLASTER TO GENERAL SPECIFICATION. MAWJI IN NAIROBI DISTRICT
2. REINFORCEMENT TO BE MILD STEEL TO BS 785.
150

3. MINIMUM COVER TO BARS SHALL BE 25mm. Client:


400
4. 1:2 CEMENT SAND RENDERING ON WALLS AND SCUM BAFFLES. Mr. MAHMOOD MAWJI & Mrs. RAHEEL
150

150 mm CONCRETE 1:2:4-3/4 GRADED

SECTION Y-Y
400

MAWJI, P.O. BOX 39142 - 00623,


SECTION X-X Y-Y
NAIROBI.
200 3,200 200 Client's Signature:...............................................................................................................
Architect:
12mm O MAIN BARS AT 300mm CENTRES
GL GL Arch. PETER NJOROGE MWAURA,
( R E G I S T E R E D A R C H I T E C T ),
P.O. BOX 64065 - CODE 00620,
LIGHTLY COMPACTED
150mm THK
SUITABLE SPORT FILLINGS
NAIROBI. KENYA.
8mm O MAIN BAR AT 12mm dia BARS AT 150mm CONC. BLOCKS GL GL
200mm C/C CENTRES BOTH WAYS TEL: +254 722 637 240
450X600mm Architect's Signature:...........................................................................................................
150

MANHOLE COVER 1,000


Drawing title:
X-X X-X

Plans, Elevations, Section and


450

COMPACTED MURRAM
E

1000 C/C

200
TO FRENCH DRAIN OR

A B C
SOAK PIT AS SPECIFIED POLYTHENE SHEET OR
ANY OTHER APPROVED Site/Location plan
MATERIAL
'H' Varries

P.N.M
150mm THK STONE
12mm O MAIN BARS
P.N.M
150

AT 200mm CENTRES BLOCKS TO DRAIN INVERT CRUSHED STONES


Designed: Drawn:

600
'H' DEPTH OF SOAK PIT AS SPECIFIED
OR DIRECTED BY DRAWING
6" PERFORATED CLAY OR
PITCH FIBRE PIPES 600mm
Checked: M. N. Approved: M. N
LONG WITH 50mm OPEN JOINTS

JUNE, 2009
150 600 200
Y-Y Date:
D
1:200,1:20 & 1:1,750
PLAN WITH COVER SLAB REINFORCEMENT SOAK PIT DETAIL FRENCH DRAIN DETAIL SCALE/S:

JOB No.:
PNM(B)6-09 DRG. No.: Sheet 2 of 2

Vous aimerez peut-être aussi