Académique Documents
Professionnel Documents
Culture Documents
1560–8530/2007/09–1–143–146
http://www.fspublishers.org
Determination of Lithology and Groundwater Quality Using
Electrical Resistivity Survey
MUHAMMAD ARSHAD1, J.M. CHEEMA AND SHAFIQUE AHMED†
Department of Irrigation and Drainage, University of Agriculture, Faisalabad–38040, Pakistan
†Assistant Agricultural Engineer, Punjab Agriculture Department, Thoker Niaz Baig, Lahore, Pakistan
1
Corresponding author’s e-mail: arsmrz@yahoo.com; Tel # 092-041-9200161-70 Ext. 3005; Fax 092-041-9200764
ABSTRACT
A resistivity survey was carried out in order to study groundwater conditions along the Jhang Branch canal, such as depth,
thickness and location of the aquifer and the type of water. Vertical electrical soundings by Schlumberger array were
conducted out at 9 locations up to a depth of 200 m. The resistivity data confirm that the aquifer consists of an alluvial aquifer.
These data were used to determine the lithology and the groundwater quality of the aquifer. Interpretation of the VES tests
indicates the presence of an alluvial aquifer that mainly consists of sand and clay. The resistivity of the aquifer between 30 to
140 m showed the increasing value, which indicated the existence of fresh groundwater. The groundwater after 140 m and up
to 200 m possesses marginally fit quality having larger TDS values than the upper zone.
and interpreting geoelectrical soundings to study the aquifer the analytic element method investigated the spatial
conditions, such as depth and nature of the alluvium, sensitivity of different electrical resistivity tomography
boundaries and location of the aquifer and groundwater (ERT) arrays. The different arrays (Wenner, Schlumberger
quality. This study can be used to protect groundwater & double-dipole) were compared using the absolute value of
supplies as a unique source of water for this area. the sensitivity and its spatial distribution. On a per
measurement basis, there was almost no difference between
MATERIALS AND METHODS the Wenner and the Schlumberger surveys. However in this
study, Schlumberger array layout was used.
The Lower Rechna Doab aquifer, which lies in the Electrical resistivity method using a terrameter SAS
central part of the Punjab province of Pakistan, is 4000. Resistivity measurements with ERM are one of the
characterized by semi-arid climate. This area faces a serious simplest methods to be used in geophysics. By putting two
water supply challenge driven by scarce water resources and electrodes into the ground and inducing an electric current
rapid population growth. The Lower Rechna Doab aquifer is through the ground, a potential field is created. Two
the major exploited aquifer in the region and it is an alluvial additional electrodes are used to measure the potential at
deposit aquifer. The study area lies on the left bank of Jhang some location. Increasingly deeper measurements are
Branch Canal at RD of 223, 227, 231, 235, 239, 255, 259, achieved by using a bigger separation between the current
261 and 275 (9 sites) about 12 km North-West of Faisalabad electrodes. Moving the current electrode and having the
city. The total length of the belt for the survey is potential electrode fixed is named the “Schlumberger”
approximately 15 km. The schematic diagram of the method.
location sites of the resistivity survey is given in Fig. 1. For this setup, a direct current was introduced into the
Electrical resistivity meter. Traditional methods for ground through two current electrodes A and B. The
characterizing protective layers include test hole drilling and potential electrodes M and N were inserted in the ground
analyses of log, with the objective being to characterize between the outer current electrodes A and B, where the
thickness and/or lateral extent of the protective layer. potential difference was measured across these two potential
Disadvantage of such investigations are that can be labor- electrodes. By measuring the current (I) between the two
intensive and expensive. The ERM method has proved very current electrodes A and B and the associated potential
popular with groundwater studies due to simplicity of the difference (V) between the potential electrodes M and N,
technique. The Terrameter SAS/4000 was employed to the apparent resistivity (ρa) was computed by the Eq 1 as
conduct resistivity survey. given below:
Terrameter SAS/4000. SAS stands for Signal Averaging
V
Systems, a method whereby consecutive readings are taken ρa = K (1)
automatically and the results are averaged continuously. The I
Terrameter SAS/4000 can operate in different modes
(resistivity, self potential & induced polarization). A useful Where
facility of the SAS/4000 is its ability to measure in four K is the geometric factor of the electrode arrangement
channels simultaneously. This implies that as well resistivity in case of Schlumberger electrode configuration, which is
and induced potential measurements as voltage given by Eq 2:
measurements can be performed up to four times faster. The 2 2
⎛ AB ⎞ ⎛ MN ⎞
electrically isolated transmitter sends out well defined and π⎜ ⎟ −⎜ ⎟
regulated signal currents, with strength up to 1000 mA and a ⎝ 2 ⎠ ⎝ 2 ⎠
voltage up to 400 V. The receiver discriminates noise and K= (2)
MN
measures voltages correlated with transmitted signal current
and also measures un-correlated DC potentials with the By repeating the Schlumberger measurements with the
same discrimination and noise rejection. The micro entire setup moved one step to the side, vertical electrical
processor, monitors, controls operations and calculates soundings (VES) were performed continuously and the
results. This makes it suitable for all sorts of resistivity resistivities along a profile were measured.
surveys. SAS results are more reliable in resistivity Data collection. Since the values measured in the field
surveying mode, it comprises a battery powered, deep correspond to resistances or potentials the first step when
penetration resistivity meter with an output sufficient for a processing the data was to calculate the apparent
current electrode separation of 200 m under good survey resistivities. These were computed using the formula
conditions. The ratio between voltage and current V/I is relevant to the electrode configuration. ERM was used in
calculated automatically and displayed in digital form in the study area. The resistivity survey was carried for 9
ohms or millions. locations along the Jhang Branch Canal during August
The “Schlumberger” and “Wenner” array 2005. The Schlumberger electrical profile configuration is
configurations are two electrode layouts those are widely presented in Fig. 2.
employed in the resistivity surveys. Furman (2003) using The Schlumberger soundings were carried with
144
DETERMINATION OF LITHOLOGY AND GROUNDWATER QUALITY / Int. J. Agri. Biol., Vol. 9, No. 1, 2007
maximum current electrode spacing (AB) 400 m (AB/2 = Fig. 1. Schematic diagram of the location of test sites
200 m). The field data acquisition was generally carried out
by moving two or four of the electrodes used, between each JHANG BRANCH
measurement.
very high (258.89 ohm-m) in the top layer, after that it 200
175
declines and achieve an average value of about 120 ohm-m.
150
The apparent resistivity at RD-239, RD-255, RD-259 and 125
RD-261 has the same pattern of apparent resistivity 100
145
ARSHAD et al. / Int. J. Agri. Biol., Vol. 9, No. 1, 2007
Table I. Sub-surface lithology based on electrical soundings provides an inexpensive method for
resistivity survey characterizing the groundwater conditions of the region.
Interpretation of the VES tests indicates the presence of an
Location Depth Resistivity Lithology alluvial aquifer that mainly consists of sand and clay. The
(m) (ohm-m)
RD-223 0-5 30.1 Surface material with low moisture
resistivity of the aquifer between 30 to 140 m showed the
5-30 52 A mixture of sand & clay >650 ppm increasing value, which indicated the existence of fresh
30-140 126 A mixture of sand & clay 400-450 ppm groundwater. VES tests also revealed three sub-surface geo-
140-200 32 700-800 ppm electric layers consisting of surface layer (top soil), alluvium
RD-227 0-6 32 Surface material with low moisture
6-33 63.4 A mixture of sand & clay >600 ppm
layer and saturated (bottom soil) layer, depth, thickness and
33-130 135 A mixture of sand & clay 400-450 ppm type of all the layers were identified.
130-200 34 700-800 ppm Recommendation. Keeping in view the results of Electrical
RD-231 0-8 90.4 Dry zone Resistivity Surveys, it was concluded that the zone of sub-
8-25 198 Dry sand with low moisture
25-200 125 450-500 ppm
soil between 30 - 140 m contains adequate volume of fresh
RD-235 0-8 94 Dry zone groundwater, which may be exploited by installing
8-27 205 Dry sand with low moisture tubewells for its utilization. The groundwater after 140 m
27-200 146 450-500 ppm and up to 200 m possesses marginally fit quality having
RD-239 0-6 33 Surface material with low moisture
6-25 56 A mixture of sand & clay 400-450 ppm
larger TDS values than the upper zone.
25-200 140 A mixture of sand & clay 400-450 ppm
RD-255 0-7 40 Low moisture zone REFERENCES
7-28 70 A mixture of sand & clay >650 ppm
28-130 144 A mixture of sand & clay 400-450 ppm
Choudhury, K., D.K. Saha and P. Chakraborty, 2001. Geophysical study for
130-200 38 600-850 ppm
saline water intrusion in a coastal alluvial terrain. J. Appl.
RD-259 0-15 19 Dry zone
Geophysics, 46: 189–200
15-40 38.4
Emenike, E.A., 2001. Geophysical Exploration for Groundwater in a
40-140 113.6 A mixture of sand & clay 450-500 ppm
Sedimentary Environment: A Case Study from Nanka over Nanka
140-200 80.1 A mixture of sand & clay 450-500 ppm
Formation in Anambra Basin, Southeastern Nigeria. Global J. Pure
RD-261 0-11 90.4 Dry zone
Appl. Sci., 7: 1
11-60 198 A mixture of sand & clay >650 ppm
Frohlich, R.K. and D. Urish, 2002. The use of geoelectrics and test wells for
60-200 125 A mixture of sand & clay 400-500 ppm
the assessment of groundwater quality of a coastal industrial site. J.
RD-275 0-7 34 Surface material with low moisture
Appl. Geophysics, 50: 261–78
7-140 156 A mixture of sand & clay 400-500 ppm
Furman, A., T.A. Ferré and A.W. Warrick, 2003. A Sensitivity Analysis of
140-200 45 A mixture of sand & clay >650 ppm
Electrical Resistivity Tomography Array Types Using Analytical
Element Modeling. Vadose Zone J., 2: 416–23
CONCLUSIONS Liu, S. and T.J. Yeh, 2004. An Integrative Approach for Monitoring Water
Movement in the Vadose Zone. Vadose Zone J., 3: 681–92
Nine sites were used to evaluate the sub-surface Matias, M.J.S., 2002. Squary array anisotropy measurements and resistivity
sounding interpretation. J. Appl. Geophysics, 49: 185–94
hydrogeological conditions to a depth of about 200 m.
Based on the interpretation of geoelectrical data, the
following conclusions were drawn: the use of geoelectrical (Received 31 July 2006; Accepted 05 December 2006)
146