Vous êtes sur la page 1sur 1

A B C D E F G G' H A B C D E F G G' H

28.85 28.85

3.15 4.55 4.50 4.50 4.50 4.50 2.70 0.45 3.15 4.55 4.50 4.50 4.50 4.50 2.70 0.45

C1/F1 C2/F1 WF-1 C2/F1 C1/F1


FTB-3 FTB-3 STB-1 2B-2 2B-2 2B-2 2B-2 2B-2 STB-1
5

5
WF-1

WF-1

WF-1

WF-1

2CG-1

2CG-1

2CG-1

2CG-1
(BELOW)

(BELOW)
STB-1

STB-1
FTB-2

FTB-2

FTB-2
FTB-2

2B-1

2B-1
STB-1

STB-1
1.40

1.40
S-2 S-2 S-2 S-2 S-2

FTB-3 FTB-1 FTB-1 FTB-1 FTB-1 FTB-1 FTB-3 2G-1 2G-1 2G-1 2G-1 2G-1
4

4
C3/F1 C4/F1 C5/F1 C5/F1 C5/F1 C5/F1 C4/F1 C3/F1 STAIR STAIR
WELL WELL

WF-2

WF-2

WF-2

WF-2

WF-2
S-1 S-1 S-1 S-1 S-1

WF-2 WF-2 WF-2 WF-2 WF-2


2B-1 2B-1
FTB-2

FTB-2

FTB-2

FTB-2

FTB-2

FTB-2

FTB-2

FTB-2
2B-1 2B-1 2B-1 2B-1 2B-1
6.50

6.50

2G-2

2G-2

2G-2

2G-2
WF-2 WF-2 WF-2 WF-2 WF-2
9.88

9.88

2G-2

2G-2

2G-2

2G-2
100mm THK. SLAB ON FILL
w/ 10mmØ BARS @ 300mm
O.C. B.W. WITH 75mm
THK. GRAVEL BED 95% S-1 S-1
COMPACTION AS PER
WF-1 WF-2 WF-2 WF-2 WF-2 S-1 S-1 S-1 S-1 S-1
ASTM D 1557
WF-1

WF-2

WF-2

WF-2

WF-2
WF-1

WF-2

WF-2

WF-2

WF-2
C6/F1
FTB-3 FTB-1 FTB-1 FTB-1 FTB-1 FTB-1 FTB-3 2G-1 2G-1 2G-1 2G-1 2G-1 2G-1 2G-3
3

3
C5/F1 C5/F1 C5/F1 C5/F1 C6/F1

2CG-1

2CG-1
2CG-1
C6/F1 C6/F1

2CG-1
S-2
1.50

1.50

2B-1
S-2 S-2

B-2

2B-1
S-2 S-1
B-2
2

2
S-2
S-1
2B-2
2B-2 2B-2 2B-2
0.48

0.48
WF-1 WF-1
2B-2
1

1
WF-1 C7/F1 2B-2
2B-2
C7/F1

FOUNDATION FRAMING PLAN SECOND FLOOR FRAMING PLAN


SCALE 1:100 METERS SCALE 1:100 METERS

A B C D E F G G' H A B C D E F G G' H
28.85 28.85

3.15 4.55 4.50 4.50 4.50 4.50 2.70 0.45 3.15 4.55 4.50 4.50 4.50 4.50 2.70 0.45

STB-1 3B-2 3B-2 3B-2 3B-2 3B-2 STB-1 RB-2 RB-3 RB-3 RB-3 RB-3 RB-3 RB-2
5

CRB-1

CRB-1

CRB-1

CRB-1
3CG-1

3CG-1

3CG-1

3CG-1
(BELOW)

(BELOW)

(BELOW)
STB-1

RB-2

RB-2
RB-2

RB-2
3B-1

3B-1

3B-1
STB-1

STB-1

STB-1
1.40

1.40
S-2 S-2 S-2 S-2 S-2 S-4 S-4 S-4 S-4 S-4 S-4 S-4

3G-1 3G-1 3G-1 3G-1 3G-1 RG-1 RG-1 RG-1 RG-1 RG-1 RG-1 RG-1
4

4
3B-1

3B-1
S-2 STAIR STAIR
WELL WELL
S-2

S-1 S-1 S-1 S-1 S-1 S-3 S-3 S-3 S-3 S-3 S-3 S-3

RG-2
3B-1 3B-1 3B-1 3B-1 3B-1 3B-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1
6.50

6.50
3B-1
3G-2

3G-2

3G-2

3G-2
9.88

9.88
3G-2

3G-2

3G-2

RG-2

RG-2

RG-2

RG-2

RG-2

RG-2

RG-2
S-1 S-1
S-1 S-1 S-1 S-1 S-1 S-3 S-3 S-3 S-3 S-3 S-3 S-3

3G-1 3G-1 3G-1 3G-1 3G-1 3G-1 3G-3 RG-1 RG-1 RG-1 RG-1 RG-1 RG-1 RG-1
3

3
3CG-1

3CG-1

CRB-1

CRB-1
CRB-1
3CG-1
3CG-1

S-2 S-4
1.50

1.50
3B-2

S-2 S-4

CRB-1
S-2 S-4

B-2
S-2 S-4
3B-2

S-1 S-3

B-2
2

2
S-2 S-4
S-1 S-3
3B-2 RB-3
3B-2 3B-2 RB-3 RB-3
3B-2
0.48

0.48
RB-3
3B-2 RB-3
1

1
3B-2 RB-3
3B-2 RB-3

THIRD FLOOR FRAMING PLAN ROOF FRAMING PLAN


SCALE 1:100 METERS SCALE 1:100 METERS

REPUBLIC OF THE PHILIPPINES


DEPARTMENT OF PUBLIC WORKS AND HIGHWAYS FOUNDATION FRAMING PLAN
CONVERGENCE AND SPECIAL SUPPORT PROGRAM (CSSP) - BASIC INFRASTRUCTURE
REGION V PROGRAM (BIP) - MULTI-PURPOSE BUILDING / FACILITIES TO SUPPORT SOCIAL SERVICES SECOND FLOOR FRAMING PLAN 1
SORSOGON 1ST DISTRICT ENGINEERING OFFICE THIRD FLOOR FRAMING PLAN
DAANG MAHARLIKA, GUINLAJON, SORSOGON CITY
CONSTRUCTION OF MULTI-PURPOSE BUILDING
ROOF FRAMING PLAN S -
LOCATION: BRGY. BITAN-O, SORSOGON CITY, SORSOGON

Vous aimerez peut-être aussi