0 évaluation0% ont trouvé ce document utile (0 vote)
56 vues3 pages
Inter-Frequency Handover is supported in the RNC if the corresponding parameter fddIFHOsupp is set to 'ON' the same conditions applies for starting the 6d / 6b measurements. Two separate MEASUREMENT CONTROL messages with "setup" for event 2d / 2f are sent to the UE.
Inter-Frequency Handover is supported in the RNC if the corresponding parameter fddIFHOsupp is set to 'ON' the same conditions applies for starting the 6d / 6b measurements. Two separate MEASUREMENT CONTROL messages with "setup" for event 2d / 2f are sent to the UE.
Droits d'auteur :
Attribution Non-Commercial (BY-NC)
Formats disponibles
Téléchargez comme DOC, PDF, TXT ou lisez en ligne sur Scribd
Inter-Frequency Handover is supported in the RNC if the corresponding parameter fddIFHOsupp is set to 'ON' the same conditions applies for starting the 6d / 6b measurements. Two separate MEASUREMENT CONTROL messages with "setup" for event 2d / 2f are sent to the UE.
Droits d'auteur :
Attribution Non-Commercial (BY-NC)
Formats disponibles
Téléchargez comme DOC, PDF, TXT ou lisez en ligne sur Scribd
When the UE has entered state CELL_DCH, the UE capability for
Inter-Frequency and GSM HO is checked. The Inter-Frequency Handover is supported in the RNC if the corresponding parameter fddIFHOsupp is set to ’ON’; in the same way the Inter-RAT Handover is supported in the RNC if the corresponding parameter fddGsmHOsupp is set to ’ON’. The Inter-Frequency Handover support is mandatory for the UE, while the Inter-RAT Handover support is not. The condition for activating P-CPICH Quality Monitoring is consequently: (fddIFHOsupp ’ON’) or (fddGsmHOsupp’ON’ and the UE supports GSM). The same conditions applies for starting the 6d/6b measurements. Two separate MEASUREMENT CONTROL messages with “setup” for event 2d / 2f are sent to the UE, one for the Ec/No measurement and another one for the Rscp measurement. Event 2d and event 2f are relevant only for cells in the Active Set of the current WCDMA RAN used frequency. Therefore no information on Inter-Frequency cells is needed. The UE is configured for 2d event triggering based on thresholds usedFreqThresh2dEcno+serviceOffset2dEcno (and usedFreqThr esh2dRscp+serviceOffset2dRscp). The UE is configured for 2f event triggering based on thresholds usedFreqThresh2dEcno+serviceOffset2 dEcno+usedFreqRelThresh2fEcno (and usedFreqThresh2dRscp+serv iceOffset2dRscp+usedFreqRelThresh2fRscp). If the WCDMA quality on the current used frequency goes below the 2d Ec/No threshold minus the corresponding hysteresis, and the condition is maintained during timeToTrigger2dEcno, (or the WCDMA quality on the current used frequency goes below the 2d Rscp threshold minus the corresponding
hysteresis, and the condition is maintained during timeToTrigger2dRscp)
then event 2d occurs, and Inter-Frequency or GSM measurements need to be performed by UE. If the WCDMA quality on the current used frequency goes above the 2f Ec/No threshold plus the corresponding hysteresis, and the condition is maintained during timeToTrigger2fEcno, (and the WCDMA RAN quality on the current used frequency goes above the 2f Rscp threshold plus the corresponding hysteresis, and the condition is maintained during timeToTrigger2fRscp) then event 2f occurs and the UE is informed to stop IF or IRAT measurements. Note that all monitored quantities of the connection must be good before IF or IRAT measurements are stopped. If the value of 2d threshold changes as a result of an Active Set update, for either the Ec/No or the Rscp measurement, due to different settings of the cell parameter usedFreqThresh2dEcno or usedFreqThresh2dRscp, the corresponding measurements using event 2d and event 2f must be modified with new thresholds for both events, computed according to the above description. This is also valid if the serviceOffset2dEcno or the serviceOffset2dRscp changes as a result of a change of UeRc state. Note: Ranges of absolute thresholds The absolute threshold values for the events 2d and 2f (based on the parameters and offsets described above) sent out to the UE in the MEASUREMENT CONTROL message, will be altered to conform to 3GPP ranges (i.e. -24..0 [dB] for EcNo and -115..-25 [dBm] for RSCP). Event 2d Handling When SRNC receives a MEASUREMENT REPORT message for event 2d from the UE, measurements for IRAT HO event 3a or IF HO event 2b is setup in the UE depending on how the parameter hoType / defaultHoType is set for the cells in the Active Set, see Section 5.2 on page 46. The measurement quantity for IRAT HO event 3a or IF HO event 2b, is set automatically depending on which part of the connection quality that is bad (CPICH Ec/No or CPICH RSCP) when the measurement is started.
Figure 11 on page 49 shows that the measured quality of WCDMA RAN is
below the used 2d threshold - hysteresis2d/2. And if this condition remains true for a time at least timeToTrigger2dEcno, event 2d occurs. For more details on hysteresis concept, see Section 3.4 on page 13. Event 2f Handling When SRNC receives a MEASUREMENT REPORT message for event 2f from the UE, measurements for IRAT HO event 3a or IF HO event 2b and associated compressed mode usage is stopped. Note that the connection quality must be good for all monitored measurements before the HO attempt is stopped. Figure 11 on page 49 shows that the measured quality of WCDMA RAN is now above the used 2f threshold plus half the value of event 2f hysteresis, if this condition remains for a time no less than timeToTrigger2fEcno then event 2f occurs. For more details on hysteresis , see Section 3.4 on page 13. 5.4 UE Tx Power Monitoring (Event 6d/6b) The Ue Tx power monitoring using events 6d and 6b is started on the same conditions as the 2d/2f events, see above. A MEASUREMENT CONTROL message with “setup” for event 6d and event 6b is prepared and sent to the UE. Event 6d and event 6b is relevant only for the Active Set of the current WCDMA RAN used frequency. The UE is configured for event trigger decision based on the threshold ueTxPowerThresh6b, event 6d does not need a specific threshold.
If the UE Tx Power reaches maximum and the condition is maintained
during timeTrigg6d, then event 6d occurs and Inter-Frequency or GSM measurements need to be performed by UE. The measurement quantity for IRAT HO event 3a or IF HO event 2b, is set automatically to CPICH RSCP, and the additional relative threshold utranRelThreshRscp is also used (see Section 6.2 on page 51 and Section 7.2 on page 67). If the UE Tx Power goes below ueTxPowerThresh6b threshold, and the condition is maintained during timeTrigg6b , then event 6b occurs and the UE is informed to stop measurements on Inter-Frequency GSM cells. No MEASUREMENT CONTROL message with the IE MEASUREMENT COMMAND set to ’Modify’ for event 6d and event 6b will be sent to the UE after an Active Set update. The reason is that these measurements are not based on Active Set cells or Monitored Set cells. Event 6d Handling When the UE Tx power reaches maximum during a time at least equal to timeTrigg6d, event 6d occurs. Note that there is no support for hysteresis for event 6d triggering, and that no threshold is used. The UE sends a MEASUREMENT REPORT message for event 6d to the SRNC. When SRNC receives the MEASUREMENT REPORT message for event 6d from the UE, measurements for IRAT HO event 3a or IF HO event 2b is set up in the UE depending on how the parameter hoType / defaultHoType is set for the cells in the Active Set, see Section 5.2 on page 46. The measurement quantity is set automatically to CPICH RSCP. The additional relative threshold utranRelThreshRscp is also used. Event 6b Handling When the UE Tx power is below the absolute threshold ueTxPowerThres h6b during a time at least equal to timeTrigg6b, event 6b occurs. Note that there is no support for hysteresis for event 6b triggering. The UE sends a MEASUREMENT REPORT message for event 6b to the SRNC. When SRNC receives the MEASUREMENT REPORT message for event 6b from the UE, ongoing HO attempts are stopped if the DL quality for both Ec/No and Rscp is also good.