isolation and noise control products and systems for over 40 years. We
pioneered the use of pre-compressed molded fiberglass for vibration isolation.
Throughout the years, we have developed and refined a complete line of noise
and vibration control products. In addition to the vibration isolation products
illustrated in the brochure, we also offer complete designed pipe riser isolation
systems, computer-assisted seismic design, engineered floating floor systems
for control of airborne and impact noise, and a complete selection of barriers,
absorbers and damping materials. Kinetics offers the engineering expertise,
laboratory, and field testing capabilities to work with you and your acoustical
consultant to develop a solution to your specific noise control problem.
800.959.1229
internal combustion engines. For equipment subject to
if the equipment is subjected to large external forces. The Affordable...easy-to-install...all-in-one roof curb AND
weight change or high wind loads, see Restrained
spring elements are complete with high frequency vibration vibration isolation for under 20-ton packaged rooftop
Spring Isolators.
control noise pads and an adjustable top load plate with lev- units! Standard features include:
eling bolts. They are available with deflections 0.71" to 4.00" • Internal seismic restraint
for loads up to 23,200 lbs. The FLS isolators are recom- • 100 mph wind restraint
mended for the isolation and restraint of large fluid-carrying • 1" or 2" deflection springs
HOUSED SPRING ISOLATORS equipment such as boilers, chillers, and cooling towers, or • Supply and return flexible connector support hardware
for equipment subjected to high wind loads. • EPDM airtight and weather-tight seal for non-ducted
applications
• High profile, non-interference aluminum equipment rail
• Accessible, interchangeable springs
Kinetics Model SL and SM Spring Isolators are high Kinetics Model ESR
deflection stable springs assembled into telescoping Heavy-duty, complete vibration isolation curb for the
aluminum or cast iron housings, complete with 1/4" BIG rooftop unit jobs!
noise pads bonded to the lower load surface. Adjusting Standard Features include:
and leveling bolts are part of the top housings. Model • 1 g seismic restraint & 125 mph wind restraint
SM spring isolators are designed with an adjustable • Access ports for each isolator to inspect, level, or
snubbing feature to reduce movement during start-up Kinetics Model FRS Spring Isolators are light capacity, change springs after equipment placement
and shutdown. Model SM isolators are available with vertically restrained isolators with rated deflections from • Up to 4" deflection, powder-coated steel springs with
deflections to 1.84" in capacities from 250 to 3,000 lbs. 0.71" to 2.00" in capacities up to 3,500 lbs. FRS isolators are 50% overload capacity
Model SL isolators are available with the same deflec- recommended for the isolation and restraint of lightweight • High-frequency noise isolation pads
tion ranges and capacities from 35 to 3,500 lbs. Kinetics mechanical equipment subject to high wind loads or equip- • Environmentally inert elastomeric seal for an air- and
Model SL and SM spring isolators are typically used to ment subject to weight change. FRS isolators can also be watertight closure between the curb and isolation rail
isolate mechanical equipment subject to freguent start- used for support of vertical pipe risers where isolation is • Supply and return duct support hardware
up and shutdown such as compressors and engine required yet vertical motion controlled. The FRS can be used • Structural steel curb with wood nailer.
generators. in outdoor applications.
2 7
ISOLATION BASES SESIMIC RESTRAINT ISOLATORS AND SNUBBERS
Model FLS Restrained Spring Vibration Isolators, offer lators and include a steel housing assembly to limit both
additional seismic restraint capabilities. The seismic lateral and vertical movement of the supported equipment
capacity ratings for isolators are determined at Kinetics during an earthquake without degrading the vibration iso-
Kinetics Model SFB Welded Structural Frame Bases are by statically loading sample isolators in the vertical, both lation of the spring during normal equipment operating
individually designed and fabricated to provide rigidity and horizontal, and in the vertical and horizontal axis simulta- conditions.
800.959.1229
support to mechanical equipment. neously until failure. The resulting maximum limits define
Standard FHS isolators incorporate a steel housing which
the restraint capacity envelope. Appropriate Model FLSS
encloses a neoprene snubber. Depending on the load and
and FHS Isolators are selected by first determining seis-
seismic zone, an optional steel spreader plate may be
mic force requirements computed at each isolator using
applied to distribute the load among concrete anchors. A
specific job specification data and local code require-
neoprene pad fitted in series with the spring is provided.
ments and then comparing those requirements to the
Equipment attachment is by way of a bolt screwed down-
Kinetics Model SBB Structural Beam Bases are com- capabilities as defined by the restraint capacity envelope.
ward through the equipment foot. Removal of the isolator
posed up of two (2) structural members used to support
for servicing can be easily accomplished as the isolator is
equipment that does not require a unitary base, such as
not fitted with a protruding stud. In conformance with all
small close-coupled pumps, fans, and air handlers. The
current building code standards, the restraining system is
structural beams provide rigidity to the equipment and
designed to withstand a minimum 1.0 g acceleration force.
accommodate the installation of vibration isolation.
Motion is limited to approximately 0.2" in any direction.
AIR MOUNTS
6 3
ISOLATION HANGERS NEOPRENE ISOLATORS
Kinetics Model RQ and RD Isolation Mounts are one- Kinetics Model NP and NG Isolation Pads are single-
piece molded neoprene, color coded for identification, ribbed or double-ribbed high quality elastomer, used
and have non-skid ribs on the bottom load surfaces. singularly or in multiple layers, separated with steel
Each isolator incorporates two (2) bolt-down holes on shims. Pads are 45 to 65 durometer and are designed
the bottom load surface and a tapped steel top load plate for 60 to 120 PSI maximum loading. NP pads are avail-
w w w. k i n e t i c s n o i s e . c o m
for attachment to the supported equipment. Model RQ able with rated deflections from 0.04" to 0.09". NG pads
isolators are designed for up to 0.15" static deflection; are available with rated deflections from 0.13" to 0.19".
Model RD is available in four (4) sizes, and eleven (11) Pads are available in 4”, 6”, 9” and 18" squares and may
Kinetics Model FH, RH, SH, SRH, and SFH Isolation Hangers are a family of products designed to capacities from 55 to 4,000 lbs. The RQ is available in be easily cut or drilled to meet field conditions. Kinetics
reduce the transmission of vibration and noise from suspended equipment and systems. FH and RH two (2) sizes and four (4) capacities from 500 to 1,300 lbs. Model NP and NG pads can be used to isolate noise,
800.959.1229
hangers incorporate fiberglass or elastomer inserts only. SH hangers incorporate a spring insert only. Kinetics Model RQ and RD are used to reduce the trans- shock, and high frequency vibration generated by
SFH and SRH hangers are combination hangers, containing a fiberglass or elastomer pad insert in mission of vibration from small pumps, vent sets, low mechanical, industrial, or process equipment located on
series with a spring. Hanger inserts are designed for up to 50% overload capacity and for rod mis- pressure packaged air-handling units, etc., and are grade or in non-critical areas.
alignment over 30-degree arc. Brackets will carry 500% overload without failure. Hangers are available selected when first cost must be minimized.
to 4” deflection and in capacities to 3,850 lbs. in standard designs. Hangers feature a Kinetics
patented No-Short spring cap which contains indexed steps to correspond to standard washer diame-
ters for the appropriate rod diameter. The rod and washer stay centered in the No-Short cap.
FIBERGLASS ISOLATORS
Kinetics Model KIP Vibration and Noise Isolation Pads Kinetics Model AC Fiberglass Isolators, complete with
are pre-compressed, inorganic, inert fiberglass load plate and mounting brackets are designed for bolt-
KINFLEX Connectors prevent stresses due to expansion Kinetics Model HSR Thrust Restraints are installed to individually coated with a flexible elastomeric moisture down applications such as vent fans, vane axial fans,
and contraction, isolate against the transfer of noise and reduce movement associated with fan thrust and are barrier. KIP fiberglass pads offer a constant natural high-speed motors, and similar equipment. AC fiber-
vibration, and compensate for misalignment. KINFLEX con- installed in pairs at the fan discharge. Model HSR uses frequency over a wide load range. KIP pads are avail- glass isolators are available in sizes with capacities
nectors absorb movement created in piping systems by 1” and 2" deflection springs in 35 to 3,500 lbs capacities. able in capacities from 20 to 16,000 lbs. per pad, in from 40 to 900 lbs. and deflections of 0.18" to 0.70".
ambient temperatures, differences in temperature of materi- thickness of 1”, 2”, 3”, and 4" and deflections from 0.18”
als handled, and differences in composition. The danger of to 1.08". KIP pads are recommended for use in the
buckling or pulling apart and the resulting maintenance costs reduction of vibration produced by pumps, chillers, cool-
are minimized. ing towers, etc. They are also effective in reducing
shock transmission from punch presses and other
impact-producing machinery.
4 5
ISOLATION HANGERS NEOPRENE ISOLATORS
Kinetics Model RQ and RD Isolation Mounts are one- Kinetics Model NP and NG Isolation Pads are single-
piece molded neoprene, color coded for identification, ribbed or double-ribbed high quality elastomer, used
and have non-skid ribs on the bottom load surfaces. singularly or in multiple layers, separated with steel
Each isolator incorporates two (2) bolt-down holes on shims. Pads are 45 to 65 durometer and are designed
the bottom load surface and a tapped steel top load plate for 60 to 120 PSI maximum loading. NP pads are avail-
w w w. k i n e t i c s n o i s e . c o m
for attachment to the supported equipment. Model RQ able with rated deflections from 0.04" to 0.09". NG pads
isolators are designed for up to 0.15" static deflection; are available with rated deflections from 0.13" to 0.19".
Model RD is available in four (4) sizes, and eleven (11) Pads are available in 4”, 6”, 9” and 18" squares and may
Kinetics Model FH, RH, SH, SRH, and SFH Isolation Hangers are a family of products designed to capacities from 55 to 4,000 lbs. The RQ is available in be easily cut or drilled to meet field conditions. Kinetics
reduce the transmission of vibration and noise from suspended equipment and systems. FH and RH two (2) sizes and four (4) capacities from 500 to 1,300 lbs. Model NP and NG pads can be used to isolate noise,
800.959.1229
hangers incorporate fiberglass or elastomer inserts only. SH hangers incorporate a spring insert only. Kinetics Model RQ and RD are used to reduce the trans- shock, and high frequency vibration generated by
SFH and SRH hangers are combination hangers, containing a fiberglass or elastomer pad insert in mission of vibration from small pumps, vent sets, low mechanical, industrial, or process equipment located on
series with a spring. Hanger inserts are designed for up to 50% overload capacity and for rod mis- pressure packaged air-handling units, etc., and are grade or in non-critical areas.
alignment over 30-degree arc. Brackets will carry 500% overload without failure. Hangers are available selected when first cost must be minimized.
to 4” deflection and in capacities to 3,850 lbs. in standard designs. Hangers feature a Kinetics
patented No-Short spring cap which contains indexed steps to correspond to standard washer diame-
ters for the appropriate rod diameter. The rod and washer stay centered in the No-Short cap.
FIBERGLASS ISOLATORS
Kinetics Model KIP Vibration and Noise Isolation Pads Kinetics Model AC Fiberglass Isolators, complete with
are pre-compressed, inorganic, inert fiberglass load plate and mounting brackets are designed for bolt-
KINFLEX Connectors prevent stresses due to expansion Kinetics Model HSR Thrust Restraints are installed to individually coated with a flexible elastomeric moisture down applications such as vent fans, vane axial fans,
and contraction, isolate against the transfer of noise and reduce movement associated with fan thrust and are barrier. KIP fiberglass pads offer a constant natural high-speed motors, and similar equipment. AC fiber-
vibration, and compensate for misalignment. KINFLEX con- installed in pairs at the fan discharge. Model HSR uses frequency over a wide load range. KIP pads are avail- glass isolators are available in sizes with capacities
nectors absorb movement created in piping systems by 1” and 2" deflection springs in 35 to 3,500 lbs capacities. able in capacities from 20 to 16,000 lbs. per pad, in from 40 to 900 lbs. and deflections of 0.18" to 0.70".
ambient temperatures, differences in temperature of materi- thickness of 1”, 2”, 3”, and 4" and deflections from 0.18”
als handled, and differences in composition. The danger of to 1.08". KIP pads are recommended for use in the
buckling or pulling apart and the resulting maintenance costs reduction of vibration produced by pumps, chillers, cool-
are minimized. ing towers, etc. They are also effective in reducing
shock transmission from punch presses and other
impact-producing machinery.
4 5
ISOLATION BASES SESIMIC RESTRAINT ISOLATORS AND SNUBBERS
Model FLS Restrained Spring Vibration Isolators, offer lators and include a steel housing assembly to limit both
additional seismic restraint capabilities. The seismic lateral and vertical movement of the supported equipment
capacity ratings for isolators are determined at Kinetics during an earthquake without degrading the vibration iso-
Kinetics Model SFB Welded Structural Frame Bases are by statically loading sample isolators in the vertical, both lation of the spring during normal equipment operating
individually designed and fabricated to provide rigidity and horizontal, and in the vertical and horizontal axis simulta- conditions.
800.959.1229
support to mechanical equipment. neously until failure. The resulting maximum limits define
Standard FHS isolators incorporate a steel housing which
the restraint capacity envelope. Appropriate Model FLSS
encloses a neoprene snubber. Depending on the load and
and FHS Isolators are selected by first determining seis-
seismic zone, an optional steel spreader plate may be
mic force requirements computed at each isolator using
applied to distribute the load among concrete anchors. A
specific job specification data and local code require-
neoprene pad fitted in series with the spring is provided.
ments and then comparing those requirements to the
Equipment attachment is by way of a bolt screwed down-
Kinetics Model SBB Structural Beam Bases are com- capabilities as defined by the restraint capacity envelope.
ward through the equipment foot. Removal of the isolator
posed up of two (2) structural members used to support
for servicing can be easily accomplished as the isolator is
equipment that does not require a unitary base, such as
not fitted with a protruding stud. In conformance with all
small close-coupled pumps, fans, and air handlers. The
current building code standards, the restraining system is
structural beams provide rigidity to the equipment and
designed to withstand a minimum 1.0 g acceleration force.
accommodate the installation of vibration isolation.
Motion is limited to approximately 0.2" in any direction.
AIR MOUNTS
6 3
FREE-STANDING SPRING ISOLATORS RESTRAINED SPRING ISOLATORS ROOFTOP ISOLATION CURBS
800.959.1229
internal combustion engines. For equipment subject to
if the equipment is subjected to large external forces. The Affordable...easy-to-install...all-in-one roof curb AND
weight change or high wind loads, see Restrained
spring elements are complete with high frequency vibration vibration isolation for under 20-ton packaged rooftop
Spring Isolators.
control noise pads and an adjustable top load plate with lev- units! Standard features include:
eling bolts. They are available with deflections 0.71" to 4.00" • Internal seismic restraint
for loads up to 23,200 lbs. The FLS isolators are recom- • 100 mph wind restraint
mended for the isolation and restraint of large fluid-carrying • 1" or 2" deflection springs
HOUSED SPRING ISOLATORS equipment such as boilers, chillers, and cooling towers, or • Supply and return flexible connector support hardware
for equipment subjected to high wind loads. • EPDM airtight and weather-tight seal for non-ducted
applications
• High profile, non-interference aluminum equipment rail
• Accessible, interchangeable springs
Kinetics Model SL and SM Spring Isolators are high Kinetics Model ESR
deflection stable springs assembled into telescoping Heavy-duty, complete vibration isolation curb for the
aluminum or cast iron housings, complete with 1/4" BIG rooftop unit jobs!
noise pads bonded to the lower load surface. Adjusting Standard Features include:
and leveling bolts are part of the top housings. Model • 1 g seismic restraint & 125 mph wind restraint
SM spring isolators are designed with an adjustable • Access ports for each isolator to inspect, level, or
snubbing feature to reduce movement during start-up Kinetics Model FRS Spring Isolators are light capacity, change springs after equipment placement
and shutdown. Model SM isolators are available with vertically restrained isolators with rated deflections from • Up to 4" deflection, powder-coated steel springs with
deflections to 1.84" in capacities from 250 to 3,000 lbs. 0.71" to 2.00" in capacities up to 3,500 lbs. FRS isolators are 50% overload capacity
Model SL isolators are available with the same deflec- recommended for the isolation and restraint of lightweight • High-frequency noise isolation pads
tion ranges and capacities from 35 to 3,500 lbs. Kinetics mechanical equipment subject to high wind loads or equip- • Environmentally inert elastomeric seal for an air- and
Model SL and SM spring isolators are typically used to ment subject to weight change. FRS isolators can also be watertight closure between the curb and isolation rail
isolate mechanical equipment subject to freguent start- used for support of vertical pipe risers where isolation is • Supply and return duct support hardware
up and shutdown such as compressors and engine required yet vertical motion controlled. The FRS can be used • Structural steel curb with wood nailer.
generators. in outdoor applications.
2 7
ABOUT KINETICS NOISE CONTROL
isolation and noise control products and systems for over 40 years. We
pioneered the use of pre-compressed molded fiberglass for vibration isolation.
Throughout the years, we have developed and refined a complete line of noise
and vibration control products. In addition to the vibration isolation products
illustrated in the brochure, we also offer complete designed pipe riser isolation
systems, computer-assisted seismic design, engineered floating floor systems
for control of airborne and impact noise, and a complete selection of barriers,
absorbers and damping materials. Kinetics offers the engineering expertise,
laboratory, and field testing capabilities to work with you and your acoustical
consultant to develop a solution to your specific noise control problem.