Vous êtes sur la page 1sur 3

F.R.L.

combination
C1000/C2500/C3000
C4000/C6500/C8000 Series
Refrigerating
type dryer Space-saving with integrated filter, regulator, and lubricator
Desiccant
type dryer Port size: 1/8 to 1
High polymer
membrane JIS symbol
dryer

Air filter

Auto. drain
/ others Specifications
F.R.L.
(Module unit) Descriptions C1000 C2500 C3000 C4000 C6500 C8000
F.R.L.
(Separate)
Compact
F.R.
Precise Appearance
regulator
F.R.L.
(Related
products)
Clean Note 7
F.R.
Electro Air filter F1000 F3000 F3000 F4000 F6000 F8000
pneumatic
regulator Components Regulator R1000 R2000 R3000 R4000 R6000 R8000
Air
booster
Lubricator L1000 L3000 L3000 L4000 L8000 L8000
Speed Working fluid Compressed air
control valve
Max. working pressure MPa 1.0
Silencer Withstanding pressure MPa 1.5
Check valve Ambient temperature range 5 to 60
/ others
Filtration rating m 5
Joint
/ tube Set pressure range MPa 0.05 to 0.85 Note 3 0.05 to 0.85
Vacuum
filter
Min. drip flow (Note 1) m3/min (ANR) 0.015 0.03 0.03 0.065 0.065 0.065
Vacuum Relief With relief mechanism
regulator
Oil capacity cm3 20 85 85 170 170 170 (MAX 360)
Suction
plate Drain capacity cm 3
12 45 45 80 80 80 (Note 2)
Magnetic Applicable oil Turbine oil Class 1 ISO VG32 (spindle oil can not be used)
spring buffer
Mechanical 1/8, 1/4 1/4, 3/8 1/4, 3/8 1/4, 3/8, 1/2 3/4, 1 3/4, 1
Port size Rc, NPT, G
pressure SW (3/8 uses an adapter) (1/2 uses an adapter) (1/2 uses an adapter) (3/4 uses an adapter) (1 1/4 uses an adapter) (1 1/4 uses an adapter)
Electronic
pressure SW Product weight kg 0.40 0.99 1.15 1.79 3.64 4.5
Contact / close Standard accessories Pressure gauge, bracket, bowl guard
contact conf.
SW
Note 1: The minimum drip flow is that at which five drops of turbine oil drip per minute at the set pressure of 0.5 MPa.
Air sensor Note 2: Drainage accumulates up to 170 cm3 only with the manual drain cock.

Pressure SW Note 3: The automatic drain's minimum operating pressure for "F" or "FF" with an automatic drain is 0.1 MPa. Initially generated drainage and air are purged until pressure reaches 0.1 MPa.
for coolant Note 4: The minimum operation pressure of the automatic drain is 0.15 MPa for the "F1" and "FF1" with an automatic drain.
Small Note 5: When using C1000 series "F1" with an automatic drain, the minimum operating pressure is 0.2 MPa and maximum operation pressure is 0.7 MPa.
flow sensor Refer to the maximum working flow table (page 318) for F1000-F1 with an automatic drain for details on maximum working flow. The working flow must be less than the maximum working flow.
Small Note 6: When element option "Y" is selected, refer to the maximum working flow table (page 318) for maximum flow. The working flow must be less than the maximum working flow.
flow controller Note 7: C2500 Series production has been discontinued. Refer to the C2500-W Series on page 398.
Flow sensor
for air Internal structure
Flow sensor
for water Regulator Lubricator
Filter
Total air
system
Total air
system
(Gamma)
IN OUT
Ending

254 นิวเมติก.com
F.R.L. Combination
How to order
How to order Refer to page 244 for the explanation of the option. A Model no. Note 2
Refrigerating
type dryer
Desiccant
C1000 6 C A6

C1000

C2500

C3000

C4000

C6500

C8000
U DSV type dryer
High polymer
Symbol Descriptions membrane
dryer
B Port size
B Port size 6 1/8 Air filter
A Model no. 8 1/4
Auto. drain
Note 2 10 3/8 / others
15 1/2 F.R.L.
20 3/4 Note 7 (Module unit)
25 1 F.R.L.
(Separate)
C Port thread type Note 1
C Port thread type Compact
Blank Rc thread
F.R.
N NPT thread
Precise
G G thread regulator
D Option Note 2 F.R.L.
(Related
D Option
Blank Filter with manual drain cock, lubricator w/o manual cock products)
C Lubricator with manual cock Clean

Drainage
F Filter/auto. drain w/ manual override (NO: Exhaust w/o pressurized) F.R.
Electro
F1 Filter/auto. drain w/ manual override (NC: No exhaust w/o pressurized) pneumatic
FF Filter/large auto. drain w/ manual override (NO: Exhaust w/o pressurized) regulator
Note 3 FF1 Filter/large auto. drain w/ manual override (NC: No exhaust w/o pressurized) Air
booster

Element Bowl material


Blank Polycarbonate bowl
Z Nylon bowl Speed
control valve
M Metal bowl
Blank 5 m Silencer
Y 0.3 m (submicron) Note 4 Check valve
detection

Blank
Differential
pressure

Without differential pressure detection port / others


Q With differential pressure detection port (Rc1/4) Joint
Flow Pressure Relief Pressure
range

Blank 0.05 to 0.85MPa / tube


L 0.05 to 0.35MPa Vacuum
Blank With relief mechanism filter
N Nonrelief type Vacuum
Blank Standard pressure gauge (with G401) regulator
direction gauge

T W/o pressure gauge (gauge port (Rc1/4) is assembled / sealed) Suction


plate
T8 Pressure gauge attached (gauge port (Rc1/4) is assembled by open)
Blank Standard flow (left right) Magnetic
spring buffer
X1 Reverse flow (right left)
Mechanical
E Assembly attachment Pages 368 to 379, 392, 393 pressure SW
E Assembly attachment Blank Without assembly attachment type Electronic
U Assembly attachment type Note 5 pressure SW
F Display unit D Distributor (D101, D401, D801) Contact / close
Assembled

contact conf.
S Pressure switch (P1100, 4100, 8100) SW
G Piping adapter set P Pressure switch (P4000) Air sensor
(Attached) V Shut-off valve (V1000, 3000)
K Lockout valve (V3010) Pressure SW
Note on model no. selection for coolant
Note 1: When G threads or NPT threads are selected, the IN,
F Display unit Small
OUT, gauge port, and drainage discharge port (metal Blank MPa display, Rc thread flow sensor
bowl automatic drain) are the target, as are J1 MPa display, NPT, G thread Small
attachments P and V. flow controller
G Piping adapter set (attached) Pages 394 to 396
Note 2: Select options for each drainage discharge, bowl Flow sensor
Blank Not attached
material, element, differential pressure detection, and for air
regulator items. When selecting options for several
A6* 1/8 piping adapter set
A8* 1/4 piping adapter set Flow sensor
items, list options in order from the top. for water
Note 3: Refer to page 246 for the automatic drain use A10* 3/8 piping adapter set
Total air
conditions. A15* 1/2 piping adapter set system
Note 4: Refer to page 318 for maximum processing flow when A20* 3/4 piping adapter set Total air
option "Y" is selected. A25* 1 piping adapter set system
(Gamma)
Note 5: Installation position for assembly attachments A32* 11/4 piping adapter set
Symbol Installation position Applicable model Adaptor screw type Ending
D F + (D) + R + L C1000 to C8000 Blank Rc thread
Standard Series

S C1000 to C8000 N NPT thread


or F + R + (S, P) + L (Excluding 1000, 6000, G G thread
P 8000 series for "P")
F.R.L. unit

H Attachment (attached)
V C1000 to C4000 H Attachment Blank Not attached
or F + R + L + (V, K) (Excluding "K" for P Pressure switch (P4000)
K 1000 Series) V Shut-off valve (V1000, V3000)
Note) Indicate "U" + "D", "S", "P", "V", and "K" when I Pressure gauge option (attached) Note 5 page 687
selecting an assembly attachment. I Pressure Blank Not attached
Use custom combinations specifications for any gauge
other combination. option G49P G49D-8-P10 (L: G49D-8-P04)
(Attached) G59P G59D-8-P10 (L: G59D-8-P04)
Note 6: If NPT is selected for the "C" piping thread type, a NPT
pressure gauge is enclosed. If Rc or G thread is
G40P G40D-8-P10 (L: G40D-8-P04)
selected, an R thread pressure gauge is enclosed. G50P G50D-8-P10 (L: G50D-8-P04)
Note 7: Piping adaptor A400-20 is attached on the both ends G41P G41D-8-P10 (L: G41D-8-P04)
of C4000-20. G52P G52D-8-P10 (L: G52D-8-P10)

นิวเมติก.com
255
F.R.L. Combination
Refrigerating
Flow characteristics
type dryer
Desiccant C1000-6 C1000-8 C2500-8-W
0.7

Secondary pressure (MPa)


Secondary pressure (MPa)

Secondary pressure (MPa)


type dryer
0.6 Primary pressure 0.7MPa Primary pressure 0.7MPa 0.6 Primary pressure 0.7MPa
High polymer
membrane 0.5 0.6
dryer 0.5
0.4 0.5
0.4
Air filter 0.4
0.3 0.3
0.3
Auto. drain 0.2 0.2
/ others 0.2
0.1 0.1
F.R.L. 0.1
(Module unit) 0 0
0.5 1.0 1.5 0 0.5 1 1.5 2 2.5
0.5 1.0 1.5
F.R.L. 3
Air flow rate (m /min. (ANR)) 3
Air flow rate (m /min. (ANR)) Air flow rate (m3/min. (ANR))
(Separate)
Compact
F.R.
C2500-10-W C3000-8 C3000-10
Precise

Secondary pressure (MPa)


0.7 Secondary pressure (MPa)
Secondary pressure (MPa)

regulator
0.6 Primary pressure 0.7MPa 0.6 0.6
F.R.L. Primary pressure 0.7MPa Primary pressure 0.7MPa
(Related 0.5 0.5
products) 0.5

Clean 0.4 0.4 0.4


F.R. 0.3 0.3 0.3
Electro
pneumatic 0.2 0.2 0.2
regulator
0.1 0.1 0.1
Air
booster 0 0 0
0.5 1 1.5 2 2.5 3 0.5 1.0 1.5 2.0 2.5 1.0 2.0 3.0 4.0 5.0
Speed
Air flow rate (m3/min. (ANR)) 3
Air flow rate (m /min. (ANR)) Air flow rate (m3/min. (ANR))
control valve

Silencer
C4000-8 C4000-10 C4000-15
Check valve
Secondary pressure (MPa)

Secondary pressure (MPa)


Secondary pressure (MPa)

/ others
0.6 Primary pressure 0.7MPa 0.6 0.6
Joint Primary pressure 0.7MPa Primary pressure 0.7MPa
/ tube 0.5 0.5 0.5

Vacuum 0.4 0.4 0.4


filter 0.3 0.3 0.3
Vacuum 0.2 0.2 0.2
regulator
0.1 0.1 0.1
Suction
plate 0 0 0
0.5 1.0 1.5 2.0 2.5 1.0 2.0 3.0 4.0 5.0 1.0 2.0 3.0 4.0 5.0
Magnetic 3 3
Air flow rate (m /min. (ANR)) Air flow rate (m /min. (ANR)) Air flow rate (m3/min. (ANR))
spring buffer
Mechanical
pressure SW
C6500-20 C6500-25
Electronic 0.7
Secondary pressure (MPa)

0.7
Secondary pressure (MPa)

pressure SW
Contact / close 0.6 Primary pressure 0.7MPa 0.6 Primary pressure 0.7MPa
contact conf. 0.5
SW 0.5
0.4 0.4
Air sensor
0.3 0.3
Pressure SW
0.2 0.2
for coolant
0.1 0.1
Small
flow sensor 0 0
1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10
Small
flow controller
Air flow rate (m3/min. (ANR)) Air flow rate (m3/min. (ANR))
Flow sensor
for air
Flow sensor
C8000-20 C8000-25
for water
Secondary pressure (MPa)

Secondary pressure (MPa)

Primary pressure 0.7MPa Primary pressure 0.7MPa


Total air 0.6
0.6
system
Total air 0.5 0.5
system 0.4
(Gamma) 0.4
0.3 0.3
Ending 0.2 0.2
0.1 0.1

0 1 2 3 4 5 6 7 8 9 10 0 1 2 3 4 5 6 7 8 9 10

Air flow rate (m3/min. (ANR)) Air flow rate (m3/min. (ANR))

256 นิวเมติก.com

Vous aimerez peut-être aussi