Vous êtes sur la page 1sur 2

Durolon HFR-1910 Página 1 de 2

Policarbonatos do Brasil
Phone: 55 11 3709-2522
Fax: 55 11 3078-7846
www.durolon.com.br

Durolon® HFR-1910
Description:
- Injection Molding
- Crystal polycarbonate - Slight blue tint
- Low viscosity product for parts with complex design
- Enhanced mold release performance
- Product complies with FDA 21 CFR 177.1580. For biomedical and food contact applications

Properties:

Rheological Properties
Method Method
Properties Unit Typical Value
ASTM ISO
Melt Flow Index (300ºC / 1.2 kg) g/10min D-1238 1133 22
Specific Gravity g/cm3 D-792 R-1183 1.2
Water Absorption (in water for 24 % D-570 - 0.23
hours at 23ºC)
Mechanical Properties
Tensile Strength MPa D-638 R-527 68
(at break) (kgf/cm2) (700)
Tensile Strength MPa D-638 R-527 63
(at yield point) (kgf/cm2) (650)
Tensile Modulus MPa D-638 R-527 2300
(kgf/cm2) (23500)
Elongation (at break) % D-638 R-527 90
Flexural Strength MPa D-790 178 90
(kgf/cm2) (920)
Flexural Modulus MPa D-790 178 2350
(kgf/cm2) (24000)
IZOD Impact Strength J/m D-256 - 640
(3.2 mm/Notched) (kg.cm/cm) (65)
Rockwell Hardness - D-785 - R120
M75
Thermal Properties
Deflection Temperature Under Load ºC D-648 75 128
(1,8 MPa)
Coefficient of Linear Thermal x10-5 D-696 - 6.5
Expansion cm/cm/ºC
Mold Shrinkage % D-955 - 0.5~0.7
Optical Properties
Light Transmission % D-1003 - 89
Refractive Index (nD25) - D-542 489 1.586

Electrical Properties
Dielectric Strength
KV/mm D-149 - 29
(1.6 mm)

http://www.policarbonatos.com.br/ing/durolon/HFR1910.htm 12/09/05
Durolon HFR-1910 Página 2 de 2

Volume Resistivity ohm.cm D-257 - >1016


Dielectric Constant 60 Hz - D-150 - 2.91
106 Hz 2.85
Dielectric Dissipation Factor 60 Hz - D150 - 6.6 x 10-4
106 Hz 9.2 x 10-3
Arc Resistance sec D-495 - 100~120
Ignition Resistance
Glow Wire Test ºC - - 850
(3.2 mm) IEC 695-2-1

Recommended Processing Conditions:

Injection Molding

- Drying: 120ºC / 4 hours


- Temperature range for processing: 240 - 300ºC
- Mold Temperature: 80 - 100ºC

Zone 1 Zone 4
Machine Zone Zone 2 Zone 3
(Nozzle) (Feed Zone)
Temperature (ºC) 260 270 260 250

Suggested starting conditions. The optimum processing conditions must be determinated experimentaly
for each process and depend on many factors such as part design, machine type, mold design and
end-use requirements of the part.

Note:
Typical values - must not be used with the intention of specifications. The above-mentioned methods must be
used as literature reference. Test samples injected under ideal processing conditions. The properties listed may
be affected by the quantity and type of pigments.

Consult the technical department about local and international certificates.

All information present here are given in good faith. They do not consist a product garantee. Please contact our
staff for product specification.

Durolon® is a registered trademark of Policarbonatos do Brasil.

http://www.policarbonatos.com.br/ing/durolon/HFR1910.htm 12/09/05