I n s t r u ct i o n M a n u a l

Wiring Centre
Model No:- TC100

Wiring centres are designed to simplify wiring and circuit checking. The TC100 does this with an easy
to understand manual suited to all popular central heating and hot water systems. Adequate wiring
space, large terminals, cable access points and cable clamps add to the simplicity of the TC100.

2 Port Motorised Valve System (S - Plan)


Room Thermostat
Model Nos RT200
WIRING CENTRE TC100
RT300
RT500 Cylinder Thermostat
Model No. CT100

N 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 HWS
(NO)
HWC

3 2
Note (NC)
2 1 14
Links shown
N L SL L AC Should be made
E
N Mains IN by the installer
protected E
N by 5amp
C 15
E E
N fuse
E
N E
NB. Neutral not required
on RT300 & RT500

Yellow/Green E
Blue (N) N
Brown (L) 4 N E N E
12 13
Orange CH Call (C) 6

Grey CH (N0) 7 L N E L N E
Boiler Pump
CH Motorised Valve
Model Nos. MV222
MV228
N 11 10 9
8 Brown (L)
11 12 6 Orange CH Call (C)
N L 1 2 3 4
7 Grey HW (N0)
Optional Frost
N L SL Thermostat E Yellow/Green
Model No. FT100 E
N Blue (N)
HW Motorised Valve Programmer
Model No. MV222 Model No. EP200

Note: links shown on diagram should be made by the installer. RT200

For ‘S Plan’ link


2-4
7 - 11
8 - 14 CT100 EP200

The TC100 Wiring Guide assumes that the Installer can identify from
the boiler, pump and controls literature to hand, the mains supply
and switch terminals.

2 X 2 PORT MOTORISED VALVE SYSTEM (S PLAN)


3 Port Motorised Valve System (Y - Plan)
Room thermostat
Model Nos RT200
WIRING CENTRE TC100
RT300 Note
RT500 Links shown Cylinder Thermostat
Should be made Model No. CT100
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 by the installer HWS HWC
N (NO) (NC)
3 2 16 2 1 14

N L SL L AC E
N Mains E
IN C 15
N E
N E
E N E

NB. Neutral not required


on RT300 & RT500

12 N E 13 N E
11 12

Optional Frost
N L SL Thermostat L N E L N E
Model No. FT100 Boiler Pump

N
Blue N N 11 8 10 9
White (CH Call) 4 N L 1 2 3 4
Orange (HW Call)* 6
Grey (HW SAT) 7
E
Yellow/Green E
Motorised valve * Varying voltages will be present on Programmer
orange conductor depending on Model No. EP200
Model Nos. MV 322 switch state of valve.
MV 328

Note: links shown on diagram should be made by the installer.


For ‘Y Plan’ link
RT200
2-4
7-8
8 - 16
13 - 14 CT100 EP200

All wiring must be to latest I.E.E. wiring


regulations - BS 7671:2001 and carried out by a
competent, qualified installer.

Warning 1 X 3 PORT MOTORISED VALVE SYSTEM (Y PLAN)


Salus Controls plc. accepts no liability for any loss or damage arising from any
errors or omissions that may be inadvertently contained within this diagram.

Salus Controls plc


Enterprise Park, Bala Gwynedd, LL23 7NL
Regional offices, England & Scotland.
Web: www.salus-tech.com Email: sales@salus-tech.com
Sales: +44 (0) 8700 766900
Maintaining a policy of continual product development Salus Controls plc. reserve the right to change
specification, design and materials of products listed in this brochure without prior notice. Technical: +44 (0) 8700 766902
Manual Issue No. IM-TC100/8-001 Email: technical@salus-tech.com