Sprecher + Schuh control switches Page
L 2 Control switches 12 - 25 amp
L 2 control switches - introduction 5-2
Ordering details 5 - 3 to 5 - 4
Off-On, changeover, ammeter and stop/start switches 5-5
Off-On, stop/start, changeover with and without spring return 5 - 6 to 5 - 9
Step switches 5 - 10 to 5 - 11
Instrumentation switches - voltmeter and ammeter 5 - 12 to 5 - 13
Reversing - 2 speed and star-delta switches 5 - 14 to 5 - 15
Base mounted Off-On, changeover and reversing switches 5 - 16 to 5 - 17
Accessories - Legends, knobs, enclosures 5 - 18
Special switches - locally assembled 5 - 19 to 5 - 20
Dimensions and technical data 5 - 21 to 5 - 22

Elektra cam switches and footswitches


V1N, B2N, V2N, V3N and VN series - 12 amp to 250 amp 5
Introduction to Elektra cam switches 5 - 23 to 5 - 25
Isolators (Off-On) 5 - 26
Changeover - with and without off 5 - 27 to 5 - 28
Reversing, motor start, star-delta, pole changing and impulse 5 - 29
Ammeter and voltmeter switches 5 - 30
Step switches - with and without off, binary code pricing guide 5 - 31
Enclosed switches - metal clad and totally insulated 5 - 32 to 5 - 33
Accessories - customer fitted and spring return feature 5 - 34 to 5 - 35
Special switches - locally assembled, common escutcheon plates 5 - 36 to 5 - 41
‘Specials’ order form 5 - 42 to 5 - 43
Dimensions for cam switches 5 - 44
Main switches with undervoltage release 5 - 45 to 5 - 46
Footswitches
Introduction to Elektra footswitches 5 - 47
Single pedal footswitches 5 - 48 to 5 - 50
Double pedal footswitches 5 - 50

5-1
L 2 control switches
acces
s Introduction
Easyminals
ter hen
w ted The traditional L 2 range of control switches are available in current ratings of 12, 16, 20, 25 amps
moun
in two frame sizes of 12/16 and 20/25 amps. The L 2 range offers a number of advantages over
traditional designs providing a high degree of compatibility with existing products, while offering a
wide choice of options and fixing methods. The modular design approach allows easy adaption to
particular customer requirements.
Screw fixing or 22.5 mm mounting
Control knobs are available with standard screw fixing (LFS) or central nut mounting requiring a single
22.5 mm hole to be drilled (LFC). Both options can be supplied by selecting the correct control knob.
The same switch body is used for both mounting types.
IP 66 control knobs
All control knobs conform to the protection classification IP 66 and are therefore suitable for use in
arduous environments.
Panel mounted
PLC compatibility
LE 2 switch
All LE 2-12 switches are supplied with electronic compatible contacts to DIN 19240 standards for
switching of PLC inputs etc.

5 All terminals are accessible from


the rear even with a mounted switch.

Optional base mounted


LA 2 control switch

Screw fixing holes fit


popular switch brands.

Safety and quality Time saving installation


Escutcheon fitted with ■ Touch-proof terminals (IP 20) ■ Captive terminal screws already open for
header plate 1)
■ IP 66 control knobs fast installation
■ Long operational life and high reliability ■ Robust screwdriver guide for easy wiring
■ Positive switching action with clearly using manual or power screwdriver
defined switching point ■ Clear terminal markings prevent wiring
■ All switch bodies are manufactured from mistakes
self-extinguishing materials (corresponding ■ Easy access to switch terminals
to class UL 94 VO) (angled screws)
■ Screw fixing or single 22.5 mm
hole mounting
1
Note: ) Refer page 5 - 18 for ordering.

5-2
L 2 control switches
Ordering details - control knobs with escutcheon
Ordering example L 2 switch body
12…25 A Cat. No.
For panel mounting

Switch body 1)
screw fixing LE 2 - -
(also for central fixing in
conjunction with control knob LFC)
LE 2
For base mounting

Switch body
screw fixing or snap-on to LA 2 - -
DIN rails EN 50 022-35
including door coupling parts
(ON/OFF switch with door interlock)

LA 2
Switch units
enter rated current (12, 16, 20, 25)
5
Circuit diagram
enter circuit diagram numbers
(eg. ‘1781’ for 1 pole off-on switch)

L 2 control knobs
Protection class IP 65
LFS 2 - A - 4 - 325
Mounting
LFS - screw fixing
LFC - 22.5 mm hole
Knob type 2)
A - standard
E - padlockable
B - with front ring
Escutcheon size 2)
4 - 48 x 48 mm
6 - 64 x 64 mm
Switch function
1
Notes: ) L2 switch can be modified for central fixing with the aid of a snap-on module
supplied with the control knob LFC 2.
2
) Other options available. Refer accessories 5-18.

Product flexibility L 2 control switch bodies - panel mounted


Off/on - changeover - stop/start
Control knobs for L 2 switch bodies
Off/on - changeover - stop/start

With the L 2 range of control switches, the switch body (switching part) Standard switch bodies for panel mounting
Please refer to opposite page for control knob selection
AC 21
AC 22
AC 23 @
400/415 V No. of Switch Switch body
Control knobs IP 66 complete with engraved escutcheons 1)
Please refer to opposite page for standard switch bodies

Knob
Function Diagram Amps 1) kW poles wafers Cat. No. 2) Price $ Function Description Engraving type Cat. No. 3) Price $

is ordered separately to the control knob. This results in a great deal of Off/On switch body

OFF
1

2
1 3
12
20
12
1
1
2
1
1
1
LE 2-12-1781
LE 2-20-1781
LE 2-12-1782
40.10
61.00
45.50
Control knobs for Off/On switch bodies

OFF
Standard knob
48 x 48 mm frame
Padlockable knob
Off-On

Off-On
A

E
LFS 2-A-4-178 I

LFS 2-E-4-178 I
12.30

22.30
20 2 1 LE 2-20-1782 76.50 48 x 48 mm frame

flexibility in the type of operating knob and mounting possibilities.


90° 2 4
ON
12 4 3 2 LE 2-12-1783 61.00 22.5 mm mounting standard knob Off-On A LFC 2-A-4-178 I 19.50
1 3 5
ON
16 5.5 3 2 LE 2-16-1783 78.00 48 x 48 mm frame
2 4 6 20 7.5 3 2 LE 2-20-1783 99.00 22.5 mm mounting 30 mm dia frame - B LFC 2-B-001 13.70
25 11 3 2 LE 2-25-1783 121.00 without escutcheon 2)
1 3 5 7

As an example, if the switch body type LE 2-12-3501 is selected, from 5 5


12 4 4 2 LE 2-12-1784 77.40 Key operated 22.5 mm mounting Off-On C LFC 2-CC-4-178 I 89.00
2 4 6 8 20 7.5 4 2 LE 2-20-1784 113.00 48 x 48 mm frame
OFF
1 3 5 7 12 4 4 2 LE 2-12-1764 72.40 (key removable in off position)
90°
16 5.5 4 2 LE 2-16-1764 89.00
2 4 6 8
20 7.5 4 2 LE 2-20-1764 113.00 Type B knob
ON

page 5 - 6, a choice of control knobs from page 5 - 7 is made.


25 11 4 2 LE 2-25-1764 139.00
With 1 early make contact

Changeover with Off switch body Control knobs for changeover with Off switch bodies
3 1
12 1 1 LE 2-12-3501 46.50 Standard knob Man - OFF - Auto A LFS 2-A-4-350R 12.30
OFF

The standard knob LFS 2-A-4-350R is the screw fixing type. For 22.5 mm 2 20 1 1 LE 2-20-3501 76.50 MAN AUTO 48 x 48 mm frame Local - OFF - Remote A LFS 2-A-4-350S 12.30
3 1 7 5
12 2 2 LE 2-12-3502 65.20 Standard knob 1- O- 2 A LFS 2-A-4-350 12.30
0 60°
2 6 20 2 2 LE 2-20-3502 113.00 48 x 48 mm frame
1 2
12 4 3 3 LE 2-12-3503 96.20 Padlockable knob Man - OFF - Auto E LFS 2-E-4-350R 22.30
3 1 7 5 11 9
16 5.5 3 3 LE 2-16-3503 121.00 48 x 48 mm frame

single hole mounting, the knob LFC 2-A-4-350R can be selected. 3 1


2

7 5
6 10

11 9 15 13
20
25
12
16
7.5
11
4
5.5
3
3
4
4
3
3
4
4 A
LE 2-20-3503
LE 2-25-3503
LE 2-12-3504
LE 2-16-3504
151.00
180.00
121.00
150.00
1
0
2
22.5 mm mounting standard knob
48 x 48 mm frame

22.5 mm mounting 30 mm dia frame


Man - OFF -
1- O-
Local - OFF -
1- O-
Auto
2
Remote
2
A
A
A
B
LFC 2-A-4-350R
LFC 2-A-4-350
LFC 2-A-4-350S
LFC 2-B-001
19.60
19.60
19.60
13.70
2 6 10 14
20 7.5 4 4 LE 2-20-3504 184.00 without escutcheon 2)

It is even possible to use this switch body with a key operator Stop/start with spring return switch body
25 11 4 4 A LE 2-25-3504 220.00 Key operated 22.5 mm 1-
48 x 48 mm frame (key removable in O position)

Control knobs for Stop/Start with spring return switch bodies


O- 2 C LFC 2-CC-4-350 89.00

12 1 1 LE 2-12-9251 47.10 Standard knob Stop - Start A LFS 2-A-4-925 12.30

LFC 2-CC-4-350. The choice is yours. STOP START N/L2


A/L1
2 4
20 1 1 LE 2-20-9251 75.50 STOP START 48 x 48 mm frame
22.5 mm mounting standard knob
48 x 48 mm frame
Stop - Start A LFC 2-A-4-925 19.60

Example
45° Key operated 22.5 mm Stop - Start C LFC 2-CC-4-925 89.00
1 3
48 x 48 mm frame
(key removable in centre position)

Notes: 1
) All switch functions available in current ratings 12, 16, 20 and 25 amp on request. Notes: 1
) All escutcheon plates have silver background with black knob unless stated otherwise.

■ Order the switch body eg. LE 2-12-3501


2
2
) Control knob for 1764 version replace 178I with suffix 175I. ) Same appearance as D7 selector switches.
3
Assembled to customer order/requirements. ) Control knob for 1764 version replace 178I with suffix 175I.

Price Schedule ‘A2’ Price Schedule ‘A2’


5-6 GST not included GST not included 5-7

■ Order the control knob eg. LFC 2-A-4-350R

5-3
L 2 control switches
Ordering details - control knobs with escutcheon
Cat. No.
With central fixing 1)
IP 66nobs (for LE switches only) LFC 2- - -
ol k With screw fixing
contr (for LE and LA switches) LFS 2- - -
Standard version
Black front frame, silver-grey legend plate,
black knob A
With front ring (LFC only), black knob, without
escutcheon (same appearance as D7 pushbutton range) B
With locking key (LFC only) - Key number 152
black escutcheon frame, silver-grey legend plate
Withdrawing position: CC
(Special key combinations CD
A E
and withdrawing positions CG
available on request) CH
CK

5
With front ring (LFC only) - Key number 152
Withdrawing position without escutcheon: DC
(Special key combinations and withdrawing DD
positions available on request) DG
(same appearance as D7 pushbutton range) DH
I G
DK
Main switches
Black front frame silver-grey legend plate,
black knob, locking facility for 1 padlock E
Grey escutcheon, black disc-type knob,
locking facility for 3 padlocks (LFS only) G 3)
Emergency off
Black frame, yellow legend plate, red knob I
N L
Main switch/emergency off
Black frame, yellow legend plate, red knob,
locking facility for 1 padlock L
Yellow escutcheon, red disc-type knob,
locking facility for 3 padlocks (LFS only) N 3)
Standard 45 mm cut-out (LFS only)
Grey cap, black knob P
Rectangular version (LFS only)
P S
Black front frame,
silver-grey legend plate,
black knob,
blank silver-grey nameplate S
Escutcheons
Size (mm) Escutcheon plate type
4 48 x 48 A, E, I, L
4 48 x 62 S
CC…CK
4 45 x 54 P
6 64 x 64 A, E, I, L 3)
6 64 x 78 S 3)
6 67 x 67 G, N 3)
Standard marking No.
according to pages 5 - 5 to 5 - 17 xxxz 2)
without legend plate 001
B DC…DK
Special engraving SPE
1
Notes: ) L 2 switches can be modified for central fixing with the aid of a snap-on module supplied with the
escutcheon plate LFC 2.
2
) The letter ‘Z’ signifies a different marking with the same circuit diagram (eg. 175 I for OFF/ON instead of
175 for 0-1).
3
) Larger escutcheon available. For main switches OFF/ON refer handles for L 7 switches in
section 11 Part A.
5-4
L 2 control switches
Quick ordering - L 2 control switches complete

Control switches complete with knob


Individually packaged

Off/On switch - panel mounted with standard knob


Description Cat. No. Price $

OFF 1 pole 12 A with screw fixing knob SA-LE2-12-1781


1 pole 12 A with 22.5 mm fixing knob CA-LE2-12-1781
ON 2 pole 12 A with screw fixing knob SA-LE2-12-1782
2 pole 12 A with 22.5 mm fixing knob CA-LE2-12-1782

Changeover switch with Off - panel mounted with standard knob


OFF 1 pole 12 A with screw fixing knob SA-LE2-12-3501
MAN AUTO
1 pole 12 A with 22.5 mm fixing knob
2 pole 12 A with screw fixing knob
CA-LE2-12-3501
SA-LE2-12-3502 5
2 pole 12 A with 22.5 mm fixing knob CA-LE2-12-3502

Changeover switch without Off - panel mounted with standard knob


1 pole 12 A with screw fixing knob SA-LE2-12-2501
MAN AUTO
1 pole 12 A with 22.5 mm fixing knob CA-LE2-12-2501
2 pole 12 A with screw fixing knob SA-LE2-12-2502
2 pole 12 A with 22.5 mm fixing knob CA-LE2-12-2502

Ammeter switch for 3 CTs - panel mounted with standard knob


0 1 pole 12 A with screw fixing knob SA-LE2-12-8751
1 pole 12 A with 22.5 mm fixing knob CA-LE2-12-8751
3 1

Stop/start switch with spring return - panel mounted with standard knob
STOP START Stop/start 12 A with screw fixing knob SA-LE2-12-9251
Stop/start 12 A with 22.5 mm fixing knob CA-LE2-12-9251

Complete LE2 switch

Complete LE2 switch individually packaged

Price Schedule ‘A2’


GST not included 5-5
L 2 control switch bodies - panel mounted
Off/on - changeover - stop/start
Standard switch bodies for panel mounting
Please refer to opposite page for control knob selection
AC 21 AC 23 @
AC 22 400/415 V No. of Switch Switch body
Function Diagram Amps 1) kW poles wafers Cat. No. 2) Price $

Off/On switch body


1
12 1 1 LE 2-12-1781
2 20 1 1 LE 2-20-1781
1 3
OFF 12 2 1 LE 2-12-1782
90° 2 4 20 2 1 LE 2-20-1782
12 4 3 2 LE 2-12-1783
1 3 5
ON
16 5.5 3 2 LE 2-16-1783
2 4 6 20 7.5 3 2 LE 2-20-1783
25 11 3 2 LE 2-25-1783
1 3 5 7
12 4 4 2 LE 2-12-1784

5 OFF
1
2 4

3
6

5 7
8 20
12
7.5
4
4
4
2
2
LE 2-20-1784
LE 2-12-1764
90°
16 5.5 4 2 LE 2-16-1764
2 4 6 8
20 7.5 4 2 LE 2-20-1764
ON
25 11 4 2 LE 2-25-1764
With 1 early make contact

Changeover with Off switch body


3 1
12 1 1 LE 2-12-3501
2 20 1 1 LE 2-20-3501
3 1 7 5
12 2 2 LE 2-12-3502
0 60°
2 6 20 2 2 LE 2-20-3502
1 2
12 4 3 3 LE 2-12-3503
3 1 7 5 11 9
16 5.5 3 3 LE 2-16-3503
2 6 10 20 7.5 3 3 LE 2-20-3503
25 11 3 3 LE 2-25-3503
12 4 4 4 LE 2-12-3504
3 1 7 5 11 9 15 13
16 5.5 4 4 A LE 2-16-3504
2 6 10 14
20 7.5 4 4 LE 2-20-3504
25 11 4 4 A LE 2-25-3504

Stop/start with spring return switch body


12 1 1 LE 2-12-9251
20 1 1 LE 2-20-9251
STOP START N/L2
A/L1
2 4
45°
1 3

1
Notes: ) All switch functions available in current ratings 12, 16, 20 and 25 amp on request.
2
) Control knob for 1764 version replace 178I with suffix 175I.
Assembled to customer order/requirements.

Price Schedule ‘A2’


5-6 GST not included
Control knobs for L 2 switch bodies
Off/on - changeover - stop/start
Control knobs IP 66 complete with engraved escutcheons 1)
Please refer to opposite page for standard switch bodies

Knob
Function Description Engraving type Cat. No. 3) Price $

Control knobs for Off/On switch bodies


Standard knob Off-On A LFS 2-A-4-178 I
48 x 48 mm frame
OFF
Padlockable knob Off-On E LFS 2-E-4-178 I

ON
48 x 48 mm frame
22.5 mm mounting standard knob Off-On A LFC 2-A-4-178 I
48 x 48 mm frame
22.5 mm mounting 30 mm dia frame - B LFC 2-B-001
without escutcheon 2)
Key operated 22.5 mm mounting Off-On C LFC 2-CC-4-178 I
48 x 48 mm frame
(key removable in off position)
5
Type B knob

Control knobs for changeover with Off switch bodies


Standard knob Man - OFF - Auto A LFS 2-A-4-350R
OFF
MAN AUTO 48 x 48 mm frame Local - OFF - Remote A LFS 2-A-4-350S
Standard knob 1- O- 2 A LFS 2-A-4-350
48 x 48 mm frame
Padlockable knob Man - OFF - Auto E LFS 2-E-4-350R
48 x 48 mm frame
22.5 mm mounting standard knob Man - OFF - Auto A LFC 2-A-4-350R
48 x 48 mm frame 1- O- 2 A LFC 2-A-4-350
0
1 2 Local - OFF - Remote A LFC 2-A-4-350S
22.5 mm mounting 30 mm dia frame 1- O- 2 B LFC 2-B-001
2
without escutcheon )
Key operated 22.5 mm 1- O- 2 C LFC 2-CC-4-350
48 x 48 mm frame (key removable in O position)

Control knobs for Stop/Start with spring return switch bodies


Standard knob Stop - Start A LFS 2-A-4-925
STOP START 48 x 48 mm frame
22.5 mm mounting standard knob Stop - Start A LFC 2-A-4-925
48 x 48 mm frame
Key operated 22.5 mm Stop - Start C LFC 2-CC-4-925
48 x 48 mm frame
(key removable in centre position)

1
Notes: ) All escutcheon plates have silver background with black knob unless stated otherwise.
2
) Same appearance as D7 selector switches.
3
) Control knob for 1764 version replace 178I with suffix 175I.

Price Schedule ‘A2’


GST not included 5-7
L 2 control switch bodies - panel mounted
Changeover without off and spring return
Standard switch bodies for panel mounting
Please refer to opposite page for control knob selection
AC 21 AC 23 @
AC 22 400/415 V No. of Switch Switch body
Function Diagram Amps 1) kW poles wafers Cat. No. Price $

Changeover without Off 60˚ switch body


3 1
12 1 1 LE 2-12-2501
2 20 1 1 LE 2-20-2501
3 1 7 5
12 2 2 LE 2-12-2502
1 2
2 6 20 2 2 LE 2-20-2502

60°
12 4 3 3 LE 2-12-2503
3 1 7 5 11 9
16 5.5 3 3 LE 2-16-2503
2 6 10
20 7.5 3 3 LE 2-20-2503
25 11 3 3 LE 2-25-2503

5 3 1 7 5 11 9 15 13
12
16
4
5.5
4
4
4
4
A
A
LE 2-12-2504
LE 2-16-2504
2 6 10 14 20 7.5 4 4 A LE 2-20-2504
25 11 4 4 A LE 2-25-2504

Changeover without Off 45° switch body


3 1
12 1 1 LE 2-12-2251
2 20 1 1 LE 2-20-2251
3 1 7 5
12 2 2 LE 2-12-2252
2 6 20 2 2 A LE 2-20-2252
1
12 4 3 3 LE 2-12-2253
2 3 1 7 5 11 9
16 5.5 3 3 LE 2-16-2253
2 6 10
20 7.5 3 3 LE 2-20-2253
45°
25 11 3 3 LE 2-25-2253
12 4 4 4 A LE 2-12-2254
3 1 7 5 11 9 15 13
16 5.5 4 4 A LE 2-16-2254
2 6 10 14 20 7.5 4 4 A LE 2-20-2254
25 11 4 4 A LE 2-25-2254

Changeover with spring return switch body


3 1
12 1 1 LE 2-12-3261
2 20 1 1 LE 2-20-3261
0 3 1 7 5
1 2
12 2 2 LE 2-12-3262
2 6 20 2 2 A LE 2-20-3262

45°

1
Notes: ) All switch functions available in current ratings 12, 16, 20 and 25 amp on request.
A Assembled to customer order/requirements.

Price Schedule ‘A2’


5-8 GST not included
Control knobs for L 2 switch bodies
Changeover without off and spring return
Control knobs IP 66 complete with engraved escutcheons 1)
Please refer to opposite page for standard switch bodies

Knob
Function Description Engraving type Cat. No. Price $

Control knobs for changeover without Off 60˚ switch bodies


Standard knob Man - Auto A LFS 2-A-4-250R
MAN AUTO
48 x 48 mm frame
Standard knob 1-2 A LFS 2-A-4-250
48 x 48 mm frame
22.5 mm mounting standard knob Man - Auto A LFC 2-A-4-250R
48 x 48 mm frame 1-2 A LFC 2-A-4-250
22.5 mm mounting 30 mm dia frame B LFC 2-B-001
2
without escutcheon )

5
Type B knob

Control knobs for changeover without Off 45˚ switch bodies


Standard knob Man - Auto A LFS 2-A-4-225R
MAN
AUTO
48 x 48 mm frame
Standard knob 1-2 A LFS 2-A-4-225
48 x 48 mm frame
22.5 mm mounting standard knob Man - Auto A LFC 2-A-4-225R
48 x 48 mm frame 1-2 A LFC 2-A-4-225
22.5 mm mounting 30 mm dia B LFC 2-B-001
2
without escutcheon )
Key operated 22.5 mm mounting 1-2 C LFC 2-CK-4-225
48 x 48 mm frame
(key removable in both positions)
Type B knob

Control knobs for changeover with spring return switch bodies


Standard knob 1-O-2 A LFS 2-A-4-325
0
1 2
48 x 48 mm frame Man - O - Auto A LFS 2-A-4-325R
22.5 mm mounting standard knob 1-O-2 A LFC 2-A-4-325
48 x 48 mm frame Man - O - Auto A LFC 2-A-4-325R
Key operated 22.5 mm mounting 1-O-2 C LFC 2-CC-4-325
48 x 48 mm frame
(key removable in O position)

1
Notes: ) All escutcheon plates have silver background with black knob unless stated otherwise.
2
) Same appearance as D7 selector switches.

Price Schedule ‘A2’


GST not included 5-9
L 2 control switch bodies - panel mounted
Step switch - 1 pole with and without off
Standard switch bodies for panel mounting 1)
Please refer to opposite page for control knob selection
AC 21
AC 22 No. of Switch Switch body
Function Diagram Amps Steps poles wafers Cat. No. Price $

Step switch with Off switch body


3 1
12 2 1 1 LE 2-12-5251
45°
2 20 2 1 1 A LE 2-20-5251
2
3 1 5
1 3 12 3 1 2 LE 2-12-5261
4 20 3 1 2 A LE 2-20-5261
3 1 7 5
0 4 12 4 1 2 LE 2-12-5271
8 20 4 1 2 A LE 2-20-5271
5
3 7 5 11 1
6
12 5 1 3 LE 2-12-5281
12 20 5 1 3 A LE 2-20-5281

5 3 7 11 9 1 5

10
12
20
6
6
1
1
3
3 A
LE 2-12-5291
LE 2-20-5291

Step switch without Off switch body


1 3 5
12 3 1 2 LE 2-12-4251
45°
4 20 3 1 2 LE 2-20-4251
3
3 1 7 5
2 4 12 4 1 2 LE 2-12-4261
8 20 4 1 2 A LE 2-20-4261
3 7 5 11 1
1 5 12 5 1 3 LE 2-12-4271
12 20 5 1 3 A LE 2-20-4271
6
3 7 11 9 1 5 12 6 1 3 LE 2-12-4281
10 20 6 1 3 A LE 2-20-4281

1
Notes: ) All switch functions available in current ratings 12, 16, 20 and 25 amp on request.
Multi-pole step switches also available (assembled to order).
A Assembled to customer order/requirements.

Price Schedule ‘A2’


5 - 10 GST not included
Control knobs for L 2 switch bodies
Step switch - 1 pole with and without off
Control knobs IP 66 complete with engraved escutcheons 1)
Please refer to opposite page for standard switch bodies

Engraving Knob
Function Description (steps) type Cat. No. Price $

Control knobs for step switch with Off switch bodies


Standard knob LFS 2 A LFS 2-A-4-525
2
48 x 48 mm frame A LFC 2-A-4-525
1 3 or 3 A LFS 2-A-4-526
22.5 mm mounting
0 4 A LFC 2-A-4-526
type LFC with standard knob
5 48 x 48 mm frame 4 A LFS 2-A-4-527
6 A LFC 2-A-4-527
5 A LFS 2-A-4-528
A LFC 2-A-4-528
6 A
A
LFS 2-A-4-529
LFC 2-A-4-529 5
Control knobs for step switch without Off switch bodies
Standard knob LFS 3 A LFS 2-A-4-425
3
48 x 48 mm frame A LFC 2-A-4-425
2 4 or 4 A LFS 2-A-4-426
22.5 mm mounting
1 5 A LFC 2-A-4-426
type LFC with standard knob
6 48 x 48 mm frame 5 A LFS 2-A-4-427
A LFC 2-A-4-427
6 A LFS 2-A-4-428
A LFC 2-A-4-428

1
Note: ) All escutcheon plates have silver background with black knob unless stated otherwise.

Price Schedule ‘A2’


GST not included 5 - 11
L 2 control switch bodies - panel mounted
Voltmeter - ammeter
Standard switch bodies for panel mounting
Please refer to opposite page for control knob selection
AC 21
AC 22 No. of Switch Switch body
Function Diagram Amps poles wafers Cat. No. Price $

Voltmeter phase to phase switch body


L2-L3 12 - 2 LE 2-12-8271
L3-L1 R/L1 6 2 A
L1-L2
W/L2 U/T1 V V/T2 16 - 2 LE 2-16-8271
B/L3
0
20 - 2 LE 2-20-8271
45° 5 3 7
25 - 2 A LE 2-25-8271

Voltmeter phase to neutral switch body


L2-N
12 - 2 LE 2-12-8291
N/O
L3-N R/L1 6 2 A
L1-N
W/L2 U/T1 V V/T2 16 - 2 LE 2-16-8291
B/L3
20 - 2 LE 2-20-8291

5
0
45° 5 3 1 7
25 - 2 A LE 2-25-8291

Voltmeter phase to phase and phase to neutral switch body


0 45°
12 - 3 LE 2-12-8251
L1-L2 L1-N N/O
10 12
R/L1 16 - 3 A LE 2-16-8251
W/L2 U/T1 V V/T2
L2-L3 L2-N B/L3
20 - 3 LE 2-20-8251
3 9 5 1
L3-L1 L3-N 25 - 3 A LE 2-25-8251

Ammeter for 3 CTs switch body


0 90° R/L1 12 1 3 LE 2-12-8751
W/L2
B/L3 16 1 3 A LE 2-16-8751
3 1
5 9 3 20 1 3 LE 2-20-8751
2 6 4
A 25 1 3 A LE 2-25-8751

Ammeter for 3 CTs (2 pole switching) switch body 1)


0 90° 12 2 5 LE 2-12-8752
R/L1
W/L2 16 2 5 A LE 2-16-8752
3 1 B/L3 14 A 5
20 2 5 LE 2-20-8752
2 13 6 1 4 11 12
25 2 5 A LE 2-25-8752

Control switches for modular distribution panels (DIN standard) 2)


For use in standard distribution boards - depth = 49 mm rating 12 amps
Type Cat. No. Price $
1 pole On/Off switch LA 2-12-1751/Q
3 pole On/Off switch LA 2-12-1753/Q
1 pole C/O switch with Off LA 2-12-3251/Q
CT ammeter switch LA 2-12-8751/Q
Voltmeter phase-phase switch LA 2-12-8271/QA
Voltmeter phase-phase-neutral switch LA 2-12-8251/QA
LA 2-12-8271/QA
DIN switch complete 1
Notes: ) Special assembly of direct ammeter switch available.
2
) DIN type switches are supplied complete with knob and engraved escutcheon.
A Assembled to customer order/requirements.

Price Schedule ‘A2’


5 - 12 GST not included
Control knobs for L 2 switch bodies
Voltmeter - ammeter
Control knobs IP 66 complete with engraved escutcheons
Please refer to opposite page for standard switch bodies

Knob
Function Description Engraving type Cat. No. Price $

Control knobs for voltmeter phase to phase switch bodies


L2-L3 Standard knob L1 - L2 A LFS 2-A-4-827A
L1-L2 L3-L1 L2 - L3
45° 48 x 48 mm frame L3 - L1
0
22.5 mm mounting standard knob L1 - L2 A LFC 2-A-4-827A
L2 - L3
48 x 48 mm frame L3 - L1

Control knobs for phase to neutral switch bodies


L2-N Standard knob L1 - N A LFS 2-A-4-829A
L1-N L3-N L2 - N
0
45° 48 x 48 mm frame L3 - N
22.5 mm mounting standard knob L1 - N A LFC 2-A-4-829A
48 x 48 mm frame
L2 - N
L3 - N
5
Control knobs for voltmeter phase to phase and phase to neutral switch bodies
L1-L2
0
L1-N Standard knob L1 - L2 (N) A LFS 2-A-4-825A
L2 - L3 (N)
L2-L3 L2-N
45° 48 x 48 mm frame L3 - L1 (N)
22.5 mm mounting standard knob L1 - L2 (N) A LFC 2-A-4-825A
L3-L1 L3-N L2 - L3 (N)
48 x 48 mm frame L3 - L1 (N)

Control knobs for ammeter for CTs or direct switch bodies

0 Standard knob O-1-2-3 A LFS 2-A-4-875


90° 48 x 48 mm frame
3 1
22.5 mm mounting standard knob O-1-2-3 A LFC 2-A-4-875
2 48 x 48 mm frame

Dimensions for DIN standard control switches (mm)

Price Schedule ‘A2’


GST not included 5 - 13
L 2 control switch bodies - panel mounted
Reversing - 2 speed - star-delta
Control knobs IP 66 complete with engraved escutcheons 1)
Please refer to opposite page for standard switch bodies
AC 21 AC 23 @
AC 22 400/415 V No. of Switch Switch body
Function Diagram Amps kW poles wafers Cat. No. Price $

Reversing 3 pole switch body


0 12 4 3 3 LE 2-12-7303
R/L1
1 2 W/L2
B/L3
16 5.5 3 3 LE 2-16-7303

12 6 2
20 7.5 3 3 LE 2-20-7303
45°
25 11 3 3 LE 2-25-7303

Reversing single phase 240 V switch body


12 1.3 1) 2 3 LE 2-12-7352
U1/T4

0
V1/T5
U/T1
V/T2

1 2 A
3 6 1 11
16 2.2 1) 2 3 LE 2-16-7352

5
1
20 2.5 ) 2 3 LE 2-20-7352
45°
25 3.2 1) 2 3 A LE 2-25-7352

2 speed (Dahlander) switch body


Y/T8
0 °
7
12 4 3 4 LE 2-12-7533
R/L1
1 2 W/L2 16 5.5 3 4 LE 2-16-7533
B/L3 U/T1 °15 4 ° W/T3
20 7.5 3 4 LE 2-20-7533
60° 13 15 2
5 13 8
° ° ° 25 11 3 4 A LE 2-25-7533
Z/T9 V/T2 X/T7

Star-delta switch body


Y
∆ U/T1 Y/T8 12 4 3 4 LE 2-12-7253
14 6
0 16 5.5 3 4 LE 2-16-7253
45°/90°

8 1
20 7.5 3 4 LE 2-20-7253
Z/T9 W/T3
R/L1 16 5 25 11 3 4 A LE 2-25-7253
W/L2
B/L3 V/T2 X/T7

13 15 2

1
Notes: ) kW ratings at AC 23, 240 volts.
A Assembled to customer order/requirements.

Catalogue No. structure for L 2 switches

LE 2 - 12 - 730 3
Panel mounting LE 2
Base mounting LA 2 Notes: All control switches of the
L 2 range are available for
Current rating
base mounting on request.
12 amp
16 amp Change LE to LA and order
20 amp as a special switch.
25 amp
Switch function
Number of poles

Price Schedule ‘A2’


5 - 14 GST not included
Control knobs for L 2 switch bodies
Reversing - 2 speed - star-delta
Control knobs IP 66 complete with engraved escutcheons 1)
Please refer to opposite page for standard switch bodies

Knob
Function Description Engraving type Cat. No. Price $

Control knobs for reversing and 2 speed switch bodies


Standard knob 1-O-2 A LFS 2-A-4-325
OFF
FWD REV
48 x 48 mm frame Fwd - O - Rev A LFS 2-A-4-730R
Padlockable knob 1-O-2 E LFS 2-E-4-325
48 x 48 mm frame Fwd - O - Rev E LFS 2-E-4-730R
22.5 mm mounting standard knob 1-O-2 A LFC 2-A-4-325
48 x 48 mm frame Fwd - O - Rev A LFC 2-A-4-730R
22.5 mm mounting 30 mm dia - B LFC 2-B-001
2
0 without escutcheon )

5
1 2
Key operated 22.5 mm mounting 1-O-2 C LFC 2-CC-4-325
48 x 48 mm frame
(key removable in off position)

Control knobs for star-delta switch bodies


Standard knob O-Y-∆ A LFS 2-A-4-725
48 x 48 mm frame
Y ∆ Padlockable knob O-Y-∆ E LFS 2-E-4-725
0
48 x 48 mm frame
22.5 mm mounting O-Y-∆ A LFC 2-A-4-725
48 x 48 mm frame
Key operated 22.5 mm mounting O-Y-∆ C LFC 2-CD-4-725
48 x 48 mm frame

1
Notes: ) All escutcheon plates have silver background with black knob unless stated otherwise.
2
) Same appearance as D7 selector switches.
3
) Other options available - refer accessories page 5 - 18.

Catalogue No. structure for control knobs with escutcheon


LFS 2 - A - 4 - 325
Mounting
LFS - screw fixing
LFC - 22.5 mm hole
Knob type 3)
A - standard
E - padlockable
B - with front ring
Escutcheon size 3)
4 - 48 x 48 mm
6 - 64 x 64 mm
Switch function

Price Schedule ‘A2’


GST not included 5 - 15
L 2 control switch bodies - base mounted
Off/On - changeover - reversing
Standard switch bodies for base mounting 1)
Please refer to opposite page for control knob selection
AC 21 AC 23 @
AC 22 400/415 V No. of Switch Switch body
Function Diagram amps kW poles wafers Cat. No. Price $

Off-on switch body


1
12 - 1 1 LA 2-12-1781
90°
2 20 - 1 1 A LA 2-20-1781
OFF
12 4 3 2 LA 2-12-1783
1 3 5
ON
16 5.5 3 2 LA 2-16-1783
2 4 6 20 7.5 3 2 LA 2-20-1783
25 11 3 2 LA 2-25-1783

Changeover with off switch body


5 1
0
2
3 1

2
12
20
-
-
1
1
1
1 A
LA 2-12-3501
LA 2-20-3501
3 1 7 5
12 - 2 2 LA 2-12-3502
60°
2 6 20 - 2 2 A LA 2-20-3502

Reversing with off switch body


0
12 4 3 3 LA 2-12-7303
L1
1 2 L2 16 5.5 3 3 LA 2-16-7303
L3

12 6 2
20 7.5 3 3 LA 2-20-7303
45°
25 11 3 3 LA 2-25-7303

Base mounted switches (DIN rail mounting)


All control switches of the L 2 series are available for base mounting on request.
For base mounting of switches shown on previous pages change LE to LA and
order as special switch.

Ordering example
Base mounted 3 pole off/on switch for 5.5 kW motor complete with control knob
and padlocking facility panel depth = 200 mm.

Example Only
Description Cat. No. Price $
2
Switch body - OFF/ON, 3 pole LA 2-16-1783 )
Control knob - OFF/ON, padlockable LFS 2-E-4-178 I 3)
Metal shaft extension, L=235mm - with coupling LA 2-G-3393 3)

1
Notes: ) Including door coupling parts (on-off with door interlock).
2
) Refer above switch bodies.
3
) Refer next page.
A Assembled to customer order/requirements.

Price Schedule ‘A2’


5 - 16 GST not included
Control knobs for L 2 switch bodies
Off/on - changeover - stop/start
Control knobs IP 66 complete with engraved escutcheons 1)
Please refer to opposite page for standard switch bodies

Knob
Function Description Engraving type Cat. No. Price $

Control knobs for off/on switch bodies


OFF Standard knob Off-On A LFS 2-A-4-178 I
48 x 48 mm frame
ON
Padlockable knob Off-On E LFS 2-E-4-178 I
48 x 48 mm frame

Control knobs for changeover with off switch bodies


0

2
Standard knob
48 x 48 mm frame
Man - OFF - Auto
1-O-2
A
A
LFS 2-A-4-350R
LFS 2-A-4-350
5
1
Padlockable knob Man - OFF - Auto E LFS 2-E-4-350R
48 x 48 mm frame 1-O-2 E LFS 2-E-4-350

Control knobs for reversing with off switch bodies


0 Standard knob Fwd - O - Rev A
Fwd Rev LFS 2-A-4-730R
48 x 48 mm frame 1-O-2 A LFS 2-A-4-325
Padlockable knob Fwd - O - Rev E LFS 2-E-4-730R
48 x 48 mm frame 1-O-2 E LFS 2-E-4-325

Accessories for base mounted switches 2)


Shaft extension including coupling L = 24 mm LA 2-G-2853
set of 2
Metal shaft extension including L = 235 mm LA 2-G-3393
coupling (with padlock facility on L = 350 mm LA 2-G-3394
switch body)
O
LA 2-G-2853 Insert-A (orange) converts to LA 2-G-3398
type 178I switching angle 3) 1
Insert-B (white) converts to suit O LA 2-G-3399
changeover switch 3) 1 2
Standard shaft for LE 2/3 switches LA 2-G-2830
Alternative shaft for LA base mounted 52 mm LA 2-G-3194
switches (standard 44 mm shaft 57 mm LA 2-G-3195
LA 2-20 supplied with LA switches)
Terminal cover for 3/4 pole 12/16 amp LA 2-12-C4
LA switches 20/25 amps LA 2-20-C4
Fixed handle (also suitable for LFS 2-P-4-001
45 mm cut-out) without inscription

1
Notes: ) All escutcheon plates have silver background with black knob unless stated otherwise.
2
) Can be used with all control knobs and switch bodies.
3
) For use with metal extension shaft LA 2-G-3393 or -3394.

Price Schedule ‘A2’


GST not included 5 - 17
L 2 control switches - accessories
Control knobs - legend plates - enclosures
Escutcheon and knob without legend plate 1)
Description Cat. No. Price $
Standard knob, 48 x 48 mm frame LFS 2-A-4-001
Padlockable knob, 48 x 48 mm frame LFS 2-E-4-001
Red knob, 48 x 48 mm frame LFS 2-I-4-001
Red padlockable knob, 48 x 48 mm frame LFS 2-L-4-001
22.5 mm mounting, 48 x 48 mm frame, standard knob LFC 2-A-4-001
22.5 mm mounting, 30 mm frame, key operator LFC 2-D_-001
for withdrawing positions DC to DK
LFS 2-A-4-001
22.5 mm mounting with lever knob LFC 2-B-001
22.5 mm mounting padlockable knob 48 x 48 mm frame LFC 2-E-4-001
22.5 mm mounting red padlockable knob 48 x 48 mm frame LFC 2-L-4-001

Blank legends and header plates


5 Silver background for 48 x 48 mm types A, E, S
Yellow background for 48 x 48 mm types I, L
LL 2-A-4-000
LL 2-I-4-000
Header plate fits all standard escutcheons L2-G-3667

Legend plates with engraving


Silver background with standard engraving 2) LL 2-A-4-XXX
LFS 2 with
3
header plate Silver background with special engraving ) LL 2-A-4-SPE
Yellow background for types I, L Off - On LL 2-I-4-178 I
Yellow background for types I, L with special engraving LL 2-I-4-SPE

Noryl enclosures, hi-impact thermoplastic IP 65


For LA switches only. 5) Pre-drilled fixing holes for ‘size 6’ plates LA2-G 3576
only. (95 x 150 x 86). Accepts LA2-12/16 (Max 3 wafers),
LA2-20/25 (Max 2 wafers)
For LA switches only. 5) Pre-drilled fixing holes for ‘size 6’ plates LA2-G 3577
only. (95 x 150 x 111). Accepts LA2-12/16 (Max 5 wafers),
LA2-20/25 (Max 4 wafers)
Enclosure with L 2 Mainly used for LE switches.4) 5) Blank lid. (95 x 150 x 86) LA2-G 3578
control switch fitted Accepts LE2-12/16 (Max 4 wafers), LE2-20/25 (Max 3 wafers)
Mainly used for LE switches. 4) 5) Blank lid. (95 x 150 x 111) LA2-G 3579
Accepts LE2-12/16 (Max 6 wafers), LE2-20/25 (Max 5 wafers)

Accessories
Nameplate holder 48 x 18 mm with blank nameplate L 2-G-3990
(for use with 22.5 mm mounting escutcheons)
Additional blank clip-on name plates for actuator sizes 48 x 48 mm, L 2-G-3667
64 x 64 mm and 67 x 67 mm (clips directly on to escutcheon)
L 2-G-3990 with special engraving 2) L 2-G-3990-SPE
Terminal cover for 3/4 pole LE switches 12/16 amp LE 2-12-C4
20/25 amp LE 2-20-C4
1
Notes: ) Control knobs with 64 x 64 mm frame available on request.
2
) Refer switch type for standard engravings xxx = diagram type.
3
) Please specify engraving required using order form for special switches. (Pages 5-19 & 5-20).
4
) LA switches may be fitted in LA2-G3578 and LA2-G3579 if required.
5
) Use of LFC operator reduces the number of wafers that the enclosure would normally accept for LFS. Please
contact your local NHP office.
Price Schedule ‘A2’
5 - 18 GST not included
L 2 special locally assembled switches

Panel mounted control switches - local assembly 1)


Switch Mechanism & Each additional wafer
size first wafer 2) 1 contact 2 contacts
Amps Price $ Price $ Price $
12 A
16 A
20 A
25 A

Control knobs and escutcheon 3)


Description Cat. No. Price $
Standard control knob screw fixing (without legend plate) LFS 2-A-4-001
22.5 mm mounting control knob (without legend plate) LFC 2-A-4-001
Standard control knob with header plate (without legend plate)
Blank legend plate
LFS 2-S-4-001
LL 2-A-4-000
5
1
Notes: ) For base mounted switches order as a special switch and add $9.30.
2
) Includes 2 contacts.
3
) Priced separately.

L 2 special switch prices includes legend plate engraving.

Special switching combinations can be assembled to order using the special ordering form
on page 5 - 20.
For pricing details refer to the table above and example below.

Pricing example
Special switch with 7 contacts, 22.5 mm mounting with special engraving, 12 amps
(4 wafers).

Mechanism & first wafer (2 contacts) $75.00


Second wafer (2 contacts) $33.00
Third wafer (2 contacts) $33.00
Fourth wafer (1 contact) $22.30
Switch body Total $163.30 (A)

LFC 2-A-4-001 control knob $15.20


LL 2-A-4-000 legend plate $ 4.40
Control knob price Total $19.60 (B)

Total switch price of switch body (A) and control knob (B) = $182.90

Price Schedule
Switch bodies ‘A4’
Control knobs ‘A2’
Special engraving ‘Nett’
GST not included 5 - 19
L 2 control switches
Special order form
For special switch manufacture, please photocopy this form, fill in the required details and mail or fax it to your nearest NHP Office
or Distributor for immediate attention.

Name: Date Quantity


Company:
Date required Order No.
Address:
Ph: ( ) Fax:

5
Switch units

Melbourne Sydney Brisbane Adelaide Perth Newcastle Townsville Rockhampton Toowoomba Cairns Darwin Hobart
FAX (03) 9429 1075 (02) 9648 4353 (07) 3399 9712 (08) 8371 0962 (08) 9277 1700 (02) 4960 2203 (07) 4775 1457 (07) 4922 2947 (07) 4633 1796 (07) 4035 6999 (08) 8947 2049 (03) 6228 9757

5 - 20
L 2 control switches
Mounting and dimensions (mm)
For LE panel mounted switches (screw fixing) Drilling plan for handle 1)
LE 2 - 12/16

Control knob
No. of wafers 1 2 3 4 5 6 7 8 Cat. No. P B Q
L for LE 2 12/16 44 54 64 74 84 94 104 114 LFS 2-A-4 28 36 48 x 48
L for LE 2 20/25 44.5 57 69.5 82 94.5 107 119.5 132 LFS 2-I-4 28 36 48 x 48
Note: 1
) Centre hole 9.5 mm. 4 hole fixing 36 x 36 mm, 2 hole fixing 32 mm. LFS 2-S-4 28 36 48 x 62

For LE panel mounted switches Drilling plan


5
22.5 mm central nut mounting

No. of wafers 1 2 3 4 5 6 7 8
L for LE 2 12/16 67.5 77.5 87.5 97.5 107.5 117.5 127.5 137.5
L for LE 2 20/25 69 81.5 94 106.5 119 131.5 144 156.5

For LA base mounted switches Drilling plan for handle

2
)

No. of wafers 1 2 3 4 Y X
L for LA 2 12/16 58 68 78 88 Min 2.5 ≥ 150
L for LA 2 20/25 58 71.5 84 96.5 Max 9.5 ≥ 90

2
Note: ) Add 2.5 mm for DIN rail mounting. All dimensions in mm (approx.)

5 - 21
L 2 control switches
Technical data
Switches L 2-12 L 2-16 L 2-20 L 2-25
Rated operating voltage IEC/VDE/BS [V] 690 690 690 690
Main switch performance VDE isolation conditions [V] 690 690 690 690
are fulfilled up to a rated
impulse voltage Uimp of [kV] 6 6 6 6
Rated thermal current Ith 40 °C IEC/VDE/BS [A] 16 20 25 30
open
Rated thermal current Ithe 60 °C IEC/VDE/BS [A] 12 16 20 25
enclosed
Rated operating current Ie
AC 1/ switching resistive loads with IEC 947 690 V [A] 12 16 20 25
AC 21 A slight overload
AC 22 A switching mixed resistive IEC 947 220-500 V [A] 12 16 20 25
and inductive loads at 690 V [A] 12 16 20 25

5
slight overload
AC 23 A periodic switching of motors
(selection criterion for main switches) 380-440 V [kW] 4 5.5 7.5 11
AC 15 switching magnetic drives, IEC 947 220-240 V [A] 5 6 7 8
motors, valves and solenoids 380-415 V [A] 3 4 5 6
500 V [A] 2 2.5 3 4
AC 3 starting of cage motors
(interruption while running) 380-440 V [kW] 4 5.5 7.5 11
Max wire sizes single or stranded mm2 2 x 2.5 2 x 2.5 6 6
2
fine strands (with sleeve) mm 2 x 2.5 2 x 2.5 2x4 2x4
Short circuit current
rated short-time (1 s) [kAeff] 0.48 0.48 0.6 0.75
max. fuse rating of circuit (gL characteristic) [A] 20 20 20 25
rated conditional [kA] 6 6 5 5
Mechanical life million operations 1 1 1 1
switching rate mechanical operations per hour 1200 1200 1200 1200
switching rate electrical operations per hour 120 120 120 120
Protection class (IEC 529)
mechanism (escutcheon) - IP 66 IP 66 IP 66 IP 66
switch body - IP 20 IP 20 IP 20 IP 20
Ambient temperature
operation min/max (˚C) -20…+60 -20…+60 -20…+60 -20…+60
storage min/max (˚C) -30…+70 -30…+70 -30…+70 -30…+70

5 - 22
Section 5
Cam switches and Footswitches
Elektra cam switches Page
V1N, B2N, V2N, V3N and VN cam switches - 12 amp to 250 amp
Introduction to Elektra cam switches 5 - 24 to 5 - 25
Isolators (Off-On) 5 - 26
Changeover - with and without off 5 - 27 to 5 - 28
Reversing, motor start, star-delta, pole changing and impulse 5 - 29
Ammeter and voltmeter switches 5 - 30
Step switches - with and without off, binary code pricing guide 5 - 31
Enclosed switches - metal clad and totally insulated 5 - 32 to 5 - 33
Accessories - customer fitted and spring return feature 5 - 34 to 5 - 35
Special switches - locally assembled, common escutcheon plates 5 - 36 to 5 - 41
‘Specials’ order form 5 - 42 to 5 - 43
Dimensions for cam switches 5 - 44
Main switches with undervoltage release 5 - 45 to 5 - 46
Footswitches
Introduction to Elektra footswitches
Single pedal footswitches
5 - 47
5 - 48 to 5 - 49 5
Double pedal footswitches 5 - 50

5 - 23
Refer catalogue ECS
Elektra Cam switches
Introduction

V1N, 12 amp range of cam switches


Compact and competitive. The V1N, 12 amp cam switch is available in 4 switch configurations including
Off-On, changeover, voltmeter selection and ammeter switches.

B2N, 20 amp range of cam switches


The B2N series is available in the single rating of 20 amps AC 21 (static load) and 5.5 kW AC 23
(motor load). By utilising from one to four chambers the B2N range are available in Off-On switches
(2, 4 and 6 pole), changeover switches (1 to 4 pole), reversing and 2 speed switches, and
ammeter/voltmeter switches.

V2N (25 amp), V3N (32 amp) range of cam switches


The range of V2N and V3N cam switches are rated at 25 amps and 32 amps AC 21 respectively.

5
The V2N/V3N may be used as control, instrument, motor and main switches.
Cam switches are developed, constructed and tested in accordance with National and International
Standards, based on VDE Regulations, DIN Standards, European Standards, IEC Publications, UL and CSA
Standards.

V2N and V3N switches

VN standard cam switches (from 50 to 250 amp)


The conventional method of constructing a cam switch is chamber by chamber each chamber having
2 contacts.
This means that by varying the number of chambers and the cams, an extremely large number of switch
programmes can be achieved. NHP assembles this type of switch in Australia.
The VN range is available in 5 frame sizes rated as follows - AC 21/AC 23 50 amp/22 kW, 63 amp/30 kW,
VN cam switch 115 amp/55 kW, 150 amp/75 kW and 250 amp/90 kW.
As with the B2N and V1N-V3N switches; the VN range is constructed with a steel shaft to give reliable
operation into the future. Also, the contact chambers are well sealed against the ingress of dust which
can cause contact failure in other switches.

T series enclosed industrial switches


This very popular range of switchgear is mostly used as a local isolator, reversing and changeover switch
for motor loads and machinery. They are available in either metal clad or a strong moulded insulated
material. Spare interiors are available for very frequently used installations.
Available ratings are (AC 21/AC 3):- 25 amp / 8 kW
45 amp / 16 kW
63 amp / 24 kW.
Industrial enclosed switch

5 - 24
Refer catalogue ECS
Elektra Cam switches
Rating chart - ordering examples

Switch size V1N B2N V2N V3N VN40 VN63 VN100 VN150 VN250
Rated insulation voltage V~ 480 500 690 690 690 690 690 690 690
Thermal permanent current (Ith) A 12 20 25 32 50 63 115 150 250
Connectable cross sections mm2 0.75-1.5 0.75-2.5 0.75-2.5 0.75-4 2.5-10 2.5-16 4-35 16-501) 35-1201)
single resp. multi-strand
Terminal screws M3 M4 M4 M4 M5 M5 2 x M4 M8 M10
Short circuit protection A max 16 20 25 35 63 80 125 160 250
fusible cut-out
AC 21 Load break switches
Ie A 12 20 25 32 50 63 115 150 250
Ue V~ 440 500 690 690 690 690 690 690 690
AC 23 Motor switches (main switches)
220 - 240 V, 3økW 1.5 3 5.5 7.5 11 18.5 30 45 55
380 - 440 V, 3økW 3 5.5 11 15 22 30 55 75 90
500 V, 3økW - 5.5 - - 18.5 30 45 90 110
660 - 690 V 2), 3økW - - - - 18.5 22 30 45 45
AC 3 Motor switches (for operational
switching) 220 - 240 V,
380 - 440 V,
500 V,
3økW
3økW
3økW
1.5
3
-
3
5.5
5.5
4
7.5
7.5
7.5
11
11
7.5
15
18.5
11
22
30
22
37
45
30
55
75
37
65
90
5
660 - 690 V 2), 3økW - - 11 15 15 22 30 45 45
DC ratings also available. Refer NHP.
Notes: DIN rail mounting is possible for B2N, V2N switches.
1
) With DIN cable lug.
Drilling pattern 2
) Rated mains voltage DIN IEC 38.
Panel mounting
V1N, B2N, V2N, Mounting methods/ordering example
V3N, VN40,
Ordering examples:
VN63, VN100
V2N A3-20P
Three pole off/on switch 25 amp panel mounted (P)
V2N A3-20C
VN150, VN250 Three pole off/on switch 25 amp single hole mounting (22.5 mm) (C)
V2N A3-20B
Three pole off/on switch 25 amp base mounted (B)

Drilling pattern for panel mounting


V1N, B2N, V2N, V3N and VN switches

Front plate
22.5 mm single hole mounting Switch size size (mm) Dim. A (mm)
3.2 B2N, V2N, V3N 30
V1N/B2N/V2N 48 x 48
V3N 72 x 72 40
24.5

VN40 72 x 72 47
VN63 96 x 96 47
VN100 96 x 96 65
22.5
VN150 125 x 125 -
Dimensions in mm -
VN250 125 x 125

Panel and single hole mounting Base mounting DIN rail / base mounting with door coupling

5 - 25
g ret
urn
Sprin vailable
Isolators Refer catalogue ECS

a
also g 5 - 38 No. of
p
refer
Switch rating chambers/ 22.5 mm single
Switch AC 21 AC 23 switching hole mount Panel mount Base Mount
type amps kW angle Cat. No. 1) Cat. No. 1) Cat. No. 1) Price $
A1 off/on switch 1 pole @ 240 V
OFF
ON 20 3.0 1/45˚ B2N A2-20C B2N A2-20P B2N A2-20B
AC SUPPLY
25 5.5 1/45˚ V2N A1-20C V2N A1-20P V2N A1-20B
0 1
32 7.5 1/45˚ V3N A1-32C V3N A1-32P V3N A1-32B
B2N … V3N 1

O 2 50 11 1/45˚ VN A1-40P VN A1-40B


I
63 18.5 1/45˚ VN A1-63P VN A1-63B
LOAD

115 30 1/45˚ VN A1-100P VN A1-100B


VN40 … VN150 150 45 1/45˚ VN A1-150P VN A1-150B
A2 off/on switch 2 pole @ 240 V
12 1.5 1/45˚ V1N A2-12P
OFF
ON
AC SUPPLY
20 3.0 1/45˚ B2N A2-20C B2N A2-20P B2N A2-20B
1
0
25 5.5 1/45˚ V2N A2-20C V2N A2-20P V2N A2-20B
1

5
32 7.5 1/45˚ V3N A2-32C V3N A2-32P V3N A2-32B
V1N… V3N 2

3 50 11 1/45˚ VN A2-40P VN A2-40B


4
O
I
63 18.5 1/45˚ VN A2-63P VN A2-63B
LOAD 115 30 1/45˚ VN A2-100P VN A2-100B
150 45 1/45˚ VN A2-150P VN A2-150B
VN40 … VN250 250 55 2/45˚ VN A2-250P VN A2-250B

A3 off/on switch 3 pole @ 415 V


OFF
ON
L1 L2 L3 20 5.5 2/45˚ B2N A4-20C B2N A4-20P B2N A4-20B
0 1

1
25 11 2/45˚ V2N A3-20C V2N A3-20P V2N A3-20B
2 32 15 2/45˚ V3N A3-32C V3N A3-32P V3N A3-32B
B2N … V3N 3
50 22 2/45˚ VN A3-40P VN A3-40B
4
O
I
5 63 30 2/45˚ VN A3-63P VN A3-63B
6
115 55 2/45˚ VN A3-100P VN A3-100B
LOAD
150 75 2/45˚ VN A3-150P VN A3-150B
VN40 … VN250 250 90 3/45˚ VN A3-250P VN A3-250B
A4 off/on switch 4 pole @ 415 V
12 3.0 2/45˚ V1N A4-12P
L1 L2 L3 N 0 1
OFF
ON
20 5.5 2/45˚ B2N A4-20C B2N A4-20P B2N A4-20B
1

2 25 11 2/45˚ V2N A4-20C V2N A4-20P V2N A4-20B


3
32 15 2/45˚ V3N A4-32C V3N A4-32P V3N A4-32B
4

V1N … V3N 5
50 22 2/45˚ VN A4-40P VN A4-40B
O
I
6 63 30 2/45˚ VN A4-63P VN A4-63B
7
115 55 2/45˚ VN A4-100P VN A4-100B
8

LOAD
150 75 2/45˚ VN A4-150P VN A4-150B
VN40 … VN250 250 90 4/45˚ VN A4-250P VN A4-250B

A6 off/on switch 6 pole @ 415 V


0 1
L1 L2 L3 U V W
OFF
ON
1
20 5.5 3/45˚ B2N A6-20C B2N A6-20P B2N A6-20B
2

3
25 5.5 3/45˚ V2N A6-20C V2N A6-20P V2N A6-20B
4

1
6 Notes: ) B2N not available as ‘A1’ single pole, or ‘A3’ 3 pole versions.
B2N … V2N 7
Standard engraving as shown, alternative engravings available on request. Standard plates
8

9 have silver background with black knob. Yellow plate with red knob available on indent.
10
Refer page 5 - 37 for common escutcheon plates. Refer table on page 5 - 25 for front
11

12
plate size and drilling pattern
U1 V1 W1 U2 V2 W2
These products are manufactured to order at short lead time.
LOAD

Price Schedule ‘B2’


5 - 26 GST not included
Refer catalogue ECS
Changeover with off
urn
g ret No. of
Sprin vailable Switch rating chambers/ 22.5 mm single
a
also g 5 - 38 Switch AC 21 AC 23 Base mount
p switching hole mount Panel mount
refer
type amps kW angle Cat. No. Cat. No. Cat. No. Price $
U1 changeover switch 1 pole with @ 240 V
off position
OFF
12 1.5 1/45˚ V1N U1-12P
MAN AUTO
20 3.0 1/45˚ B2N U1-20C B2N U1-20P B2N U1-20B
AC SUPPLY 1 0 2 25 5.5 1/45˚ V2N U1-20C V2N U1-20P V2N U1-20B
2 32 7.5 1/45˚ V3N U1-32C V3N U1-32P V3N U1-32B
V1N … V3N 1

0 4
50 11 1/60˚ VN U1-40P VN U1-40B
1 2
LOAD
63 18.5 1/60˚ VN U1-63P VN U1-63B
115 30 1/60˚ VN U1-100P VN U1-100B
150 45 1/60˚ VN U1-150P VN U1-150B
VN40 … VN250
250 55 2/60˚ VN U1-250P VN U1-250B
U2 changeover switch 2 pole with @ 240 V
off position
20 3.0 2/45˚ B2N U2-20C B2N U2-20P B2N U2-20B

5
OFF
MAN AUTO
AC SUPPLY 1 0 2 25 5.5 2/45˚ V2N U2-20C V2N U2-20P V2N U2-20B
2
32 7.5 2/45˚ V3N U2-32C V3N U2-32P V3N U2-32B
1
4 50 11 2/60˚ VN U2-40P VN U2-40B
B2N … V3N 6
0 5 63 18.5 2/60˚ VN U2-63P VN U2-63B
1 2
8
115 30 2/60˚ VN U2-100P VN U2-100B
LOAD
150 45 2/60˚ VN U2-150P VN U2-150B
VN40 … VN250 250 55 4/60˚ VN U2-250P VN U2-250B

U3 changeover switch 3 pole with @ 415 V


off position
12 3.0 3/45˚ V1N U3-12P
OFF
L1 L2 L3 1 0 2
MAN AUTO
20 5.5 3/45˚ B2N U3-20C B2N U3-20P B2N U3-20B
2
1 25 11 3/45˚ V2N U3-20C V2N U3-20P V2N U3-20B
4
6
32 15 3/45˚ V3N U3-32C V3N U3-32P V3N U3-32B
V1N … V3N 5
8
50 22 3/60˚ VN U3-40P VN U3-40B
0
1 2
0 63 30 3/60˚ VN U3-63P VN U3-63B
9
12 115 55 3/60˚ VN U3-100P VN U3-100B
LOAD 150 75 3/60˚ VN U3-150P VN U3-150B
VN40 … VN250 250 90 6/60˚ VN U3-250P VN U3-250B

U4 changeover switch 4 pole with @ 415 V


off position L1 L2 L3 N 1 0 2

OFF 2
20 5.5 4/45˚ B2N U4-20C B2N U4-20P B2N U4-20B
MAN AUTO 1
4 25 11 4/45˚ V2N U4-20C V2N U4-20P V2N U4-20B
6
5 32 15 4/45˚ V3N U4-32C V3N U4-32P V3N U4-32B
8
10
50 22 4/60˚ VN U4-40P VN U4-40B
B2N … V3N
9
0
12
63 30 4/60˚ VN U4-63P VN U4-63B
1 2
14
115 55 4/60˚ VN U4-100P VN U4-100B
13
16 150 75 4/60˚ VN U4-150P VN U4-150B
LOAD
VN40 … VN250 250 90 8/60˚ VN U4-250P VN U4-250B
U6 changeover switch 6 pole with
off position L1 L2 L3 U V W
2
1 0 2 @ 415 V
1

OFF
4
6 25 11 6/45˚ V2N U6-20C V2N U6-20P V2N U6-20B
MAN AUTO 5
8
10
9
12
Notes: Standard engraving as shown, alternative engravings available on request.
14
13
Standard plates have silver background with black knob. Yellow plate with red knob
16
18 available on indent. Refer page 5 - 37 for common escutcheon plates.
17
V2N 20 Refer table on page 5 - 25 for front plate size and drilling pattern.
22
21
24
These products are manufactured to order at short lead time.
LOAD

Price Schedule ‘B2’


GST not included 5 - 27
Changeover without off Refer catalogue ECS

urn
g ret
Sprin vailable No. of
a
also g 5 - 38
Switch rating chambers/ 22.5 mm single
p Switch
refer AC 21 AC 23 switching hole mount Panel mount Base mount
type amps kW angle Cat. No. Cat. No. Cat. No. Price $
UD1 changeover switch 1 pole @ 240 V
without off position
MAN
AUTO
20 3.0 1/45˚ B2N UD1-20C B2N UD1-20P B2N UD1-20B
AC SUPPLY 25 5.5 1/45˚ V2N UD1-20C V2N UD1-20P V2N UD1-20B
0 1
32 7.5 1/45˚ V3N UD1-32C V3N UD1-32P V3N UD1-32B
1
B2N … V3N 50 11 1/60˚ VN UD1-40P VN UD1-40B
1 2
2 63 18.5 1/60˚ VN UD1-63P VN UD1-63B
115 30 1/60˚ VN UD1-100P VN UD1-100B
LOAD

VN40 … VN100
UD2 changeover switch 2 pole @ 240 V
without off position
MAN
AUTO
20 3.0 2/45˚ B2N UD2-20C B2N UD2-20P B2N UD2-20B
AC SUPPLY

0 1 25 5.5 2/45˚ V2N UD2-20C V2N UD2-20P V2N UD2-20B

5 1 32 7.5 2/45˚ V3N UD2-32C V3N UD2-32P V3N UD2-32B


B2N … V3N 2 50 11 2/60˚ VN UD2-40P VN UD2-40B
1
2
3 63 18.5 2/60˚ VN UD2-63P VN UD2-63B
4
115 30 2/60˚ VN UD2-100P VN UD2-100B
150 45 2/60˚ VN UD2-150P VN UD2-150B
LOAD

VN40 … VN250 250 55 4/60˚ VN UD2-250P VN UD2-250B


UD3 changeover switch 3 pole @ 415 V
without off position
MAN
L1 L2 L3
20 5.5 3/45˚ B2N UD3-20C B2N UD3-20P B2N UD3-20B
AUTO 0 1

25 11 3/45˚ V2N UD3-20C V2N UD3-20P V2N UD3-20B


1

2
32 15 3/45˚ V3N UD3-32C V3N UD3-32P V3N UD3-32B
3 50 22 3/60˚ VN UD3-40P VN UD3-40B
B2N … V3N
4
1 63 30 3/60˚ VN UD3-63P VN UD3-63B
2 5

6
115 55 3/60˚ VN UD3-100P VN UD3-100B
150 75 3/60˚ VN UD3-150P VN UD3-150B
VN40 … VN250
LOAD 250 90 6/60˚ VN UD3-250P VN UD3-250B

UD4 changeover switch 4 pole @ 415 V


without off position
0 1
MAN
L1 L2 L3 N
20 5.5 4/45˚ B2N UD4-20C B2N UD4-20P B2N UD4-20B
AUTO
1
25 11 4/45˚ V2N UD4-20C V2N UD4-20P V2N UD4-20B
2

3
32 15 4/45˚ V3N UD4-32C V3N UD4-32P V3N UD4-32B
4 50 22 4/60˚ VN UD4-40P VN UD4-40B
B2N … V3N
1 5
63 30 4/60˚ VN UD4-63P VN UD4-63B
2
6
115 55 4/60˚ VN UD4-100P VN UD4-100B
7

8
150 75 4/60˚ VN UD4-150P VN UD4-150B
VN40 … VN250 LOAD 250 90 8/60˚ VN UD4-250P VN UD4-250B
UD4 MB Make before break @ 415 V
changeover switch 1
4 pole without Off 63 30 4/60˚ VN UD4-63PMB VN UD4-63BMB
2
(ideal for 115 55 4/60˚ VN UD4-100PMB VN UD4-100BMB
generator
changeovers) Notes: Standard engraving as shown, alternative engravings available on request. Standard plates
have silver background with black knob. Yellow plate with red knob available on indent.
Refer table on page 5 - 25 for front plate size and drilling pattern. Refer page 5 - 37 for
VN63 … VN100
common escutcheon plates.
These products are manufactured to order at short lead time.

Price Schedule ‘B2’


5 - 28 GST not included
Refer catalogue ECS
urn
Reversing - star delta - pole changing
g ret
Sprin vailable
a
also g 5 - 38
p
refer No. of
Switch rating chambers/ 22.5 mm single
Switch AC 21 AC 23 switching hole mount Panel mount Base mount
type amps kW angle Cat. No. Cat. No. Cat. No. Price $

FOR
OFF
REV
W3 reversing switch @ 415 V
3 phase
20 5.5 3/45˚ B2N W3-20C B2N W3-20P B2N W3-20B
AC SUPPLY 1 0 2 25 11 3/60˚ V2N W3-20C V2N W3-20P V2N W3-20B
B2N … V3N 32 15 3/60˚
2 V3N W3-32C V3N W3-32P V3N W3-32B
0
1 1
1 50 22 3/60˚ VN W3-40P VN W3-40B
4
63 30 3/60˚ VN W3-63P VN W3-63B
LOAD 115 55 3/60˚ VN W3-100P VN W3-100B
VN40 … VN150
150 75 3/60˚ VN W3-150P VN W3-150B
FOR
OFF
REV
WE4 single phase reversing switches (for motors with capacitor or centrifugal switch)
AC SUPPLY 1 0 2

V2N … V3N
1
0
1
1
4
6 25
@ 240 V
5.5 3/60˚ V2N WE4-20C V2N WE4-20P V2N WE4-20B 5
5 32 7.5 3/60˚ V3N WE4-32C V3N WE4-32P V3N WE4-32B
8
50 11 3/60˚ VN WE4-40P VN WE4-40B
LOAD
VN40

KOM motor starter control ‘off’, on, start’ with spring return to ‘on’
AC SUPPLY 0 1 Start
0

1 @ 240 V
↑ 2
START 25 5.5 1/60˚-30˚ V2N KOM-20C V2N KOM-20P V2N KOM-20B
1
4

V2N LOAD

Y star delta switch @ 415 V


O Y
L1 25 11 4/60˚ V2N Y-20C V2N Y-20P V2N Y-20B
0 U1

Y W2 32 15 4/60˚ V3N Y-32C V3N Y-32P V3N Y-32B


L2


V1 50 22 4/60˚ VN Y-40P VN Y-40B
U2
L3
W1
V2

V2N … VN40 LOAD

P11 pole-changing switch for 2 speeds (single winding)


1 0 2

0 1U
@ 415 V
1 2 L1
2U 25 11 4/60˚ V2N P11-20C V2N P11-20P V2N P11-20B
1V
L2 32 15 4/60˚ V3N P11-32C V3N P11-32P V3N P11-32B
2V
1W
L3
50 22 4/60˚ VN P11-40P VN P11-40B
2W
V2N … VN40 LOAD

KIM impulse switch

SUPPLY 0 1
@ 240 V
0 1
20 3.0 1/30˚ B2N KIM-20C B2N KIM-20P B2N KIM-20B
2
25 5.5 1/30˚ V2N KIM-20C V2N KIM-20P V2N KIM-20B
1

B2N … V2N Notes: Standard engraving as shown, alternative engravings available on request.
LOAD
Standard plates have silver background with black knob.
Yellow plate with red knob available on indent.
Refer table on page 5 - 25 for front plate size and drilling pattern.
Refer page 5 - 37 for common escutcheon plates.
These products are manufactured to order at short lead time.
Price Schedule ‘B2’
GST not included 5 - 29
Refer catalogue ECS
Ammeter - Voltmeter
Switch No. of
Voltmeter changeover rating chambers/ 22.5 mm single
switches AC 21 switching hole mount Panel mount Base mount
amps Voltage angle Cat. No. Cat. No. Cat. No. Price $
V1 to measure PH to N voltages
0
0 L1N L2N L3N
L1N
L1 25 690 V 2/45˚ V2N V1-20C V2N V1-20P V2N V1-20B
L2N L2

L3N L3

LOAD

V2 to measure PH to PH voltages
0 L1L2 L2 L3 L3 L1
0
L1L2 L1

L2L3
1 25 690 V 2/45˚ V2N V2-20C V2N V2-20P V2N V2-20B
L2
L1L3 2

L3

LOAD

5 V3 to measure PH to PH and PH to N voltage

12 440 V 3/45˚ V1N V3-12P


0 20 500 V 4/45˚ B2N V3-20C B2N V3-20P B2N V3-20B
L1L3 L1N

L2L3 L2N
25 690 V 3/45˚ V2N V3-20C V2N V3-20P V2N V3-20B
L1L2 L3N

V1N … V2N

Ammeter changeover switch


MT3/MA ammeter changeover, panel mounted @ 415 V
For direct reading with CTs
0
12 CTs - 3/90˚ V1N MA-12P
L3 L1 20 CTs - 4/90˚ B2N MA-20C B2N MA-20P B2N MA-20B
For direct reading without CTs or for CTs in line with meter as indicated
L2
25 11/CTs - 5/90˚ V2N MT3-20C V2N MT3-20P V2N MT3-20B
V1N … VN40 32 15 - 5/90˚ V3N MT3-32C V3N MT3-32P V3N MT3-32B
50 22 - 5/90˚ - VN MT3-40P VN MT3-40B

Connection diagram example Connection diagram example Notes: ‘MA’ switches are for use with CTs only.
for B2N MA20_ for V2N, V3N, VN MT3_ Standard engraving as shown, alternative
engravings available on request.
Supply / CTs
L1 L2 L3 SUPPLY 0 L1 L2 L3 0 L1 L2 L3
Refer table on page 5 - 25 for front
plate size and drilling pattern.
L1 Refer page 5 - 37 for common
L1
escutcheon plates.
2 These products are manufactured to
L2 order at short lead time.
L2
1

L3

L3

LOAD LOAD

Ammeter

Refer to
SECTION 9
for Analogue Meters
Price Schedule ‘B2’
5 - 30 GST not included
Refer catalogue ECS
Step switches

‘S’ Step switches single pole - Without OFF


Switch No. of
rating chambers/ 22.5 mm single Panel
No. of AC 21 switching hole mount mount Base mount
steps amps angle Cat. No. Cat. No. Cat. No. Price $
SUPPLY
1 2 3 4 5 6 7 8
2 25 2/45˚ V2N S2-20C V2N S2-20P V2N S2-20B
1

2 3 20 2/45˚ B2N S3-20C B2N S3-20P B2N S3-20B


4

8
3 25 2/45˚ V2N S3-20C V2N S3-20P V2N S3-20B
10

12 4 20 2/45˚ B2N S4-20C B2N S4-20P B2N S4-20B


14

16
4 25 2/45˚ V2N S4-20C V2N S4-20P V2N S4-20B
LOAD

S8 5 25 3/45˚ V2N S5-20C V2N S5-20P V2N S5-20B


6 25 3/45˚ V2N S6-20C V2N S6-20P V2N S6-20B
7 25 4/45˚ V2N S7-20C V2N S7-20P V2N S7-20B
1
12 2
11 3
8 25 4/45˚ V2N S8-20C V2N S8-20P V2N S8-20B
9 25 5/30˚ V2N S9-20C V2N S9-20P V2N S9-20B

5
10 4
9 5
8 6 10 25 5/30˚ V2N S10-20C V2N S10-20P V2N S10-20B
7
11 25 6/30˚ V2N S11-20C V2N S11-20P V2N S11-20B
S12
12 25 6/30˚ V2N S12-20C V2N S12-20P V2N S12-20B

‘S’ Step switches single pole - With OFF


SUPPLY
1 2 3 4 5

1 2 25 2/45˚ V2N S02-20C V2N S02-20P V2N S02-20B


2

4 3 20 2/45˚ B2N S03-20C B2N S03-20P B2N S03-20B


6

8 3 25 2/45˚ V2N S03-20C V2N S03-20P V2N S03-20B


10

LOAD
4 20 2/45˚ B2N S04-20C B2N S04-20P B2N S04-20B
S05
4 25 2/45˚ V2N S04-20C V2N S04-20P V2N S04-20B
5 25 3/45˚ V2N S05-20C V2N S05-20P V2N S05-20B
6 25 3/45˚ V2N S06-20C V2N S06-20P V2N S06-20B
0 7 25 4/45˚ V2N S07-20C V2N S07-20P V2N S07-20B
11 1
10 2 8 25 4/45˚ V2N S08-20C V2N S08-20P V2N S08-20B
9 3
8 4
9 25 5/30˚ V2N S09-20C V2N S09-20P V2N S09-20B
7
6
5 10 25 5/30˚ V2N S010-20C V2N S010-20P V2N S010-20B
11 25 6/30˚ V2N S011-20C V2N S011-20P V2N S011-20B
S011

Binary code switches single pole with off - pricing guide


Order as SPECIAL - Refer NHP
Switching Positions
No. of No. of Indicative
1 2 3 4 5 6 7 8 9 10 11 12 steps chambers Contacts Price $
1 2 Up to 3 + Off 1 Standard contacts
3 4
Gold contacts
5 6

7 8 Up to 11 + Off 2 Standard contacts


Gold contacts
Typical circuit diagram to
suit 11 step + Off

Notes: Multi-pole step switches are available, as are higher amperage switches - contact NHP or distributor.
Refer table on page 5 - 25 for front plate size and drilling pattern.
These products are manufactured to order at short lead time.

Price Schedule ‘B2’


GST not included 5 - 31
Refer catalogue ECS
Enclosed type - industrial
ON / OFF switch Reversing switch Changeover switch
AC 3 triple pole triple pole triple pole
kW @
Ith 415 V Cat. No. Price $ Cat. No. Price $ Cat. No. Price $
Side operated – metal clad (IP 54)
Side operated -
metal clad 25 A 8 TAG1625A TWG168KW TUG1625A
TWG 16/8 kW
45 A 16 TAG3245A TWG3216KW TUG3245A
63 A 24 - TWG5024KW TUG5063A
Side operated – insulated (IP 52)
25 A 8 TAT1625A TWT168KW TUT1625A
45 A 16 TAT3245A TWT3216KW TUT3245A
63 A 24 TAT5063A TWT5024KW TUT5063A
Spare switch interiors only – to suit metal clad or insulated enclosed switches
Side operated -
insulated 25 A 8 TAO1625A TWO168KW TUO1625A
TAT 16/25 A
45 A 16 TAO3245A TWO3216KW TUO3245A

5 63 A 24 TAO5063A TWO5024KW TUO5063A

Spare handles – to suit the above switches


TBH16P
To suit switch rating Type Cat. No. Price $
16/25 A, 16/8 kW Plastic TBH16P
16/25 A, 16/8 kW Metal TBH16M
32/45 A, 32/16 kW, 50/63 A, 50/24 kW Metal TBH32M

TBH16M

Compact enclosed switches – TB enclosure type


AC 3 ON/OFF switch Reversing switch Changeover switch
kW @ triple pole triple pole triple pole
lth 415 V Cat. No. Price $ Cat. No. Price $ Cat. No. Price $
25 A 7.5 V2N A3-20E V2N W3-20E V2N U3-20E
32 A 11 V3N A3-32E V3N W3-32E V3N U3-32E
50 A 15 VN A3-40E VN W3-40E VN U3-40E
V3N W3 32E
63 A 22 VN A3-63E VN W3-63E VN U3-63E

Notes: Alternative front plate options available on request (eg. 3SD + ES plates - refer page 5 - 34).
Available on indent only.

ROBU
DESIG ST
N
V3N U3 32E

Price Schedule ‘B2’


5 - 32 GST not included
Refer catalogue ECS
Enclosed type - industrial
Enclosed rotary type – (larger enclosure for more cabling room) IP 65 1)

ON / OFF switch Reversing switch Changeover switch


AC 3 triple pole triple pole triple pole
kW @ Encl. Encl. Encl.
Ith 415 V Type Cat. No. Price $ Type Cat. No. Price $ Type Cat. No. Price $
20 A 5.5 1 B2N A4-20LE 5 B2N W3-20LE 5 B2N U3-20LE
25 A 7.5 1 V2N A3-20LE 1 V2N W3-20LE 1 V2N U3-20LE
32 A 11 2 V3N A3-32LE 3 V3N W3-32LE 3 V3N U3-32LE
50 A 15 2 VN A3-40LE 4 VN W3-40LE 4 VN U3-40LE
63 A 22 6 VN A3-63LE 7 VN W3-63LE 7 VN U3-63LE
115 A 37 7 VN A3-100LE - 8 VN U3-100LE
150 A 55 10 VN A3-150LE - 11 VN U3-150LE
250 A 65 11 VN A3-250LE - 12 VN U3-250LEPLAST
250 A 65 - - 13 VN U3-250LESTEEL

V2N A3-20LE VN A3-40-LE VN U3-100LE

Enclosure type - dimensions (mm)

Enclosure Enclosure
Type Description H x W x D 4) Type Description H x W x D 4)
1 PC 100/75 130 x 80 x 75 8 PC 281918G 280 x 190 x 180
2
2 PC 125/75 130 x 130 x 75 9 PC 281918G ) 280 x 190 x 230
3 PC 125/100 130 x 130 x 100 10 PC 382813G 380 x 280 x 130
3
4 PC 150/125 180 x 130 x 125 11 PC 382818G ) 380 x 280 x 230
5 PC 100/100 130 x 80 x 100 12 PL 230 3) 380 x 280 x 280
6 PCR 191913 190 x 190 x 130 13 MAS 0606040 600 x 600 x 400
7 PCR 281913 280 x 190 x 130

1
Notes: ) The enclosure selection is the minimum recommended size, for other requirements refer your local NHP office.
2
) These enclosures include JZR extension wall.
3
) These enclosures include PZR extension wall.
4
) Depth of enclosure does not include handle and faceplate.
These products are manufactured to order at short lead time.
WE A
L
MAKE SO CUSTO
REQU TO YOUR M
IREME
NTS

Price Schedule ‘B2’


GST not included 5 - 33
Refer catalogue ECS
Cam switches LEGEND - Switch types
Accessory kits (customer fitted) A - Off/On
PII - Pole changing
U - C/O with off
UD - C/O without off
W - Reversing
Lockplate ES To suit
ES plate Dimensions Switch model switch type Cat. No. 1) 2) Price $
1 padlock facility, when
48 x 48 mm V1N, B2N, V2N A ES48YOFFON
switch is in the
non-operating position. ES48SOFFON
ES48Y01
ES48S01
72 x 72 mm V3N (panel mount), A ES72YOFFON
VN 40 ES72SOFFON
ES72Y01
ES72S01
96 x 96 mm VN63, VN100 A ES96YOFFON
ES96SOFFON
ES96Y01

5 ES96S01

3SD plate Circular Lockplate 3SD


Provision for 3 padlocks,
65 x 65 mm V1N, B2N, V2N A 3SD65_OFF/ON
when switch is in the
vertical (12 o’clock) UD 3SD65_MAN/AUT
(for Centre mount add
position. U 3SD65_M/O/A
‘C’ to part number eg:
3SD65C OFF/ON) P11 3SD65_1/0/2
W 3SD65_F/O/R
V3N A 3SD65 0/1
(Centre mount UD 3SD65 1/2
only) U, P11 3SD65 1/0/2
W 3SD65 F/O/R
72 x 72 mm V3N A 3SD72 OFF/ON
(Panel mount A 3SD72 0/1
only) UD 3SD72S 1/2
U, P11 3SD72S 1/0/2
W 3SD72S F/O/R
VN40 A 3SD72 OFF/ON
A 3SD72 0/1
UD 3SD72H 1/2
U 3SD72H 1/0/2
W 3SD72H F/O/R
96 x 96 mm VN63, VN100 A 3SD96 OFF/ON
A 3SD96 0/1
UD 3SD96 1/2
U 3SD96 1/0/2
W 3SD96 F/O/R
125 x 125 mm VN150, VN250 A 3SD125 0/1
UD 3SD125 1/2
U 3SD125 1/0/2
W 3SD125 F/O/R

Spade terminals Cat. No. Price $


V2N (Per contact) All types ST 20

1
Notes: ) Yellow plate (suffix Y) normally used with red knob.
Price Schedule ‘B2’ 2
) Silver plate (suffix S) normally used with black knob.
5 - 34 GST not included
Refer catalogue ECS
Cam switches
Accessory kits (customer fitted)

Interlocking plate and knob (2KS)


The 2KS interlocking plate and knob will accommodate up to two padlocks on the knob when the switch is
at the 12 o’clock position. The 2KS is suitable for all V2N and V3N switches and is available as a silver
face plate with black knob combination. The faceplate is engraved for permanent identification.

Switch model To suit switch type Cat. No. Price $


V2N, V1N (Panel and base mount only) A 1) 2KS48
V3N (Panel and base mount only) A 1) 2KS65
1
V3N (Panel and base mount only) A ) 2KS72

Interlocking plates with lock bar (3S) and (5S)


The 3S and 5S interlock plates are located behind the face plate and will accommodate a maximum of

5
three padlocks on the 3S and five padlocks on 5S model. Please note; the 3S interlocking plate also suits
the V2N and V3N switches but due to a shaft modification, requires fitting by NHP only.
(Refer page 5 - 38 - NHP fitted accessories section).

Switch model To suit switch type Cat. No. Price $


VN40 A, MT3 3S405SQ
VN40 U, UD, P11, W 3S406HX

Interlocking plates with lock bar (5S)


Switch model To suit switch type Cat. No. Price $
VN63 A 5S637SQ
VN100 A 5S1007SQ
VN150/250 A 5S15011SQ

Terminal covers
1 piece required for insulating supply side only. 2 pieces required to fully insulate each chamber.

Switch model Cat. No. Price $


B2N TC B1N
VN 100 TC 100

IN
PRO CREASE
REARTECTION
OF S T
WITCO
H
Two chamber terminal shields
1 piece required for insulating supply side only, 2 pieces required to fully insulate two chambers.

Switch model Cat. No. Price $


VN 40 TS 40
VN 63 TS 63

1
Notes: ) Standard option supplied with face plate engraved OFF-ON. Other options available refer NHP.
Available on indent only.

Price Schedule ‘B2’


GST not included 5 - 35
‘Special’ locally assembled cam switches Refer catalogue ECS
Spring return and engraving plates

Spring return feature


This feature must be ordered with standard switch. This option cannot be added later.
Ordering example: for 1 way return add R1
to existing switch catalogue number Switch To suit ADD ADD
model switch type Cat. No. Price $
eg. V2NA1-20PR1.
V2N – VN63 A,UD R1
OFF O
V3N A,UD R1
ON I I
V2N – VN63 U,W R2L
V3N U,W R2L
V2N – VN63 U,W R2R
R1 R2
1 way return 2 way return V3N U,W R2R
V2N – VN63 U,W R2
O O
I I I I V3N U,W R2

5
R2L – 1 way R2R – 1 way return
return LHS only RHS only

Heading plate - For switch designation


An engraved label can be added to the top of all V1N, B2N, V2N and V3N ('C' mount) switches with the use
of a heading plate. Standard engraved plates are available as Main switch, Isolator, Ammeter and Voltmeter
or can be engraved to suit specifications. The heading plates are a two-part kit comprising an engraved
silver plate and carrier. The carrier can be either screw mounted or applied using adhesive backing.

Engraved Size (mm) Cat. No. Price $


MAIN SWITCH 16 x 48 HP48 M
ISOLATOR 16 x 48 HP48 I
AMMETER 16 x 48 HP48 A
VOLTMETER 16 x 48 HP48 V
(BLANK) 16 x 48 HP48 B
(BLANK) 21 x 65 HP65 B

Special engraving (escutcheon plates) Non-standard legend plates


Specially built switches will often require specially engraved escutcheon plates that can be designed to suit any
specification. An extensive list of common escutcheons is also available as standard, displayed on page 5 - 37.
Note: Prices for common escutcheon plates, as spares or replacement, are as below.

DUTY 2 Description Switch model Cat. No. Price $


DUTY 1 DUTY 48 x 48 mm front plate V1N, B2N, V2N EPSPEC 48
1+2 65 x 65 mm front plate V3N_C EPSPEC 65
72 x 72 mm front plate V3N_P, VN40 EPSPEC 72
96 x 96 mm front plate VN63, VN100 EPSPEC 96
EPD1D2D3
125 x 125 mm front plate VN150, VN250 EPSPEC 125

Notes: This product is manufactured to order at short lead time.

Price Schedule ‘B2’


5 - 36 GST not included
Refer catalogue ECS
‘Special’ locally assembled cam switches
Engraving options - size 48 x 48 mm
These plates can be ordered by the following Cat. Nos. Refer page 5 - 36 for pricing

OFF O OFF MAN AUTO 1


ON I ON AUTO MAN 2

EPOO EPOI EPORO EPMA EPAM EP12

2 HIGH OFF STOP OPEN DUTY


1 LOW AUTO START CLOSE S/BY

EP21 EPHL EPOA EPSS EPOC EPDS

LEAD UP SLOW FAST OFF OFF


LAG DOWN FAST SLOW MAN AUTO AUTO MAN

5
EPLL EPUD EPSF EPFS EPMOA EPAOM

0 OFF OFF OFF OFF NORMAL


1 2 FOR REV ON Y HI LOW TEST


START

EP102 EPFOR EPOOS EPOSD EPHOL EPNT

OFF REMOTE OFF OFF OFF


NORM O/RIDE REMOTE LOCAL RAISE LOWER
NORM TEST LOCAL PUMP PUMP
1 2

EPNOT EPRL EPNO EPROL EPPOP EPRAOL

OFF OPEN DUTY 2 MED OFF STOP


UP DOWN AUTO CLOSE DUTY DUTY LOW HIGH LOW HIGH REMOTE LOCAL
1 1+2

EPUOD EPAOC EPD1D2D3 EPLMH EPLOH EPRSL

OFF OFF OFF OFF OFF OFF


AUTO TEST MAINS GEN MAINS ALT MAINS S/BY AUTO ON OPEN CLOSE

EPAOT EPMOG EPMOAL EPMOS EPAOO EPOOC

OFF OFF OFF OFF OFF OFF


MAINS BYPASS UPS BYPASS 2-1 1-2 SEC GEN SEC AUX ON RESET

EPMOB EPUOB EP2O11 EPSOG EPSOA EPOOR


Note: Other special engraved plates available locally on request. Other size plates also available, refer NHP.
5 - 37
‘Special’ locally assembled cam switches
Pricing specials
Design your own switch. Includes standard knob and specially engraved faceplate
Switch model Current rating Mechanism + Additional Auxiliaries $ 1)
Cat. No. (A) AC 21 1st chamber $ chambers $ 25 A 32 A 50 A
V2N 25
V3N 32
VN40 50
VN63 63
VN100 115
VN150 150
Two contact sets
possible per chamber VN250 250
1
Notes: ) 25 A & 32 A auxiliaries only possible on 45° and 90° switching options.
Base mount switch must use an additional chamber for an auxiliary.
2
) Gold contacts also available, add an additional $ per contact set ( per chamber).

From the guide above, a price for a special switch can be determined.

5 This price is applicable for Panel mount (P), Single hole mount V2N, V3N (C) and Base mount (B) models.

For special switches requiring additional accessories refer to the quick reference pricing guide on the
following page.

Accessory descriptions
A list of ‘Customer fit’ accessories can be found on pages 5-34 to 5-35.
The following accessories must be purchased at the time of ordering the switch.

• Spring return [R] This option returns the actuator of the switch to its former position.
Ideal for motor start or momentary switching. (V2N & V3N)

• Door interlock [TKTV] This option suits base mount switches achieving mechanical
interlocking with the door-mounted actuator. This prevents the door from opening while the
switch is in the ‘ON’ position. (Safety)

• Extension shaft [EXS] This option is suited to base mount switches allowing for mounting
within a deep enclosure.

• Weatherproof seal [WPK] This option increases the degree of protection at the front of the
switch from IP54 (standard) to IP65. This option is standard on all single hole mount switches
(C mount).

• Key actuators [Z] This option replaces the standard knob type actuator with a key,
making it ideal for authorised switching (Safety) (B2N, V2N, V3N)

• Key interlock [ZSH] This option combines the traditional knob type actuator with key
interlock. This allows a switch to be operated normally with the option to lock in the ‘OFF’
position. Ideal for authorised switching applications (Safety)

• Protective boot [PB] This option shrouds the termination points of a panel mounted switch,
preventing contact with live parts and limiting the ingress of dust and water. Degree of protection IP54.
(V1N, B2N, V2N, VN40, maximum 7 chambers. V3N, maximum 8 chambers. VN63 maximum 6 chambers).

• Extended terminals [AT] This option increases the terminal surface area,
allowing for larger cables to be terminated. (VN40-VN100)

Price Schedule ‘B4’


5 - 38 GST not included
‘Special’ locally assembled cam switches
Accessory options guide
Add price of accessory to ‘Special’ switch prices on page 5 - 38.

Switch Model - Price $


FEATURE CODE B2N V2N V3N VN40 VN63 VN100 VN150/250
Spring O
R
return I I

Door TKTV
interlock

Extension EXS
shaft

Weatherproof WPK
seal

Key operated Z

Key interlock
5
ZSH

Protective PB
boot 1)

Extended AT
terminal per per per
chamber chamber chamber

Header plate HP

C mount

1
Note: ) Includes V1N type - price as B2N.

Linked Auxiliary Contacts


One of the most common accessories to be fitted to any switchgear product are auxiliary contacts. In most cases, the addition of an
auxiliary contact is straightforward however, with a cam switch auxiliary, switching can become extremely complex. Because of the
complexity, the auxiliary contacts need to be ordered as an NHP Fitted option.

Switch Switch Auxiliary switch body size


For all base mounted optioned switches,
Type Model 2) 25 A 32 A 50 A
auxiliaries are obtained by using contacts
identical to the main switch. On panel mounted 45/90º VN40 (50A) ✔ ✔ -
options, the auxiliary contacts may be smaller Switching VN63 (63A) ✔ ✔ ✔
than the main switch. When ordering auxiliary A, MT3 VN100 (115A) ✔ ✔ ✔
contacts please remember, two contacts can be
VN150 (150A) ✔ ✔ ✔
fitted per chamber. Also, gold contacts are
VN250 (250A) ✔ ✔ ✔
available for fitting on V2N (25A) switches to
allow low voltage switching (such as PLC 30/60º VN40 (50A) - - -
inputs). Switching VN63 (63A) - - ✔
U, UD, W3 VN100 (115A) - - ✔
WE4, Y, P11 VN150 (150A) - - ✔
VN250 (250A) - - ✔

2
Note: ) Price, refer page 38.

Price Schedule ‘B4’


GST not included 5 - 39
‘Special’ locally assembled cam switches
Ordering procedure
How to complete the ‘special’ order forms on pages 5-42 and 5-43
Please read carefully Name:
To:
ELECTRICAL ENGINEERING PRODUCTS PTY. LTD.
Company: A.B.N. 84 004 304 812

Step 1 Fill in your company details. Address:


At: ie: (Insert branch)

1
Phone No.:
Step 2 Fill in your order number, date, quantity and
date required.
Order No. Date: _____/_____/_____
2 Quantity: Date required: ____/____/____

A – SWITCH TYPE & RATING


Refer page 5 - 25
EXISTING SWITCH NUMBER
3
Step 3 Select the current rating of the switch. QUANTITY
AMPS

B – MOUNTING
SINGLE HOLE (C) PANEL (P) BASE (B) ENCLOSED (LE)
Step 4 Select the mounting method. Refer page 5 -25

(V2N & V3N ONLY)


4
Step 5 Select operator type or locking option. C i – HANDLE AND PLATE STANDARD
Refer pages 5 - 34 – 5 - 35 5TD 3SD ES 3S 5S 2KS

(OFF/ON ONLY)

Step 6 Select accessory options as required. 5


C ii – HANDLE AND PLATE SPECIAL
Refer page 5 - 39 Z (KEY OPERATED) ZSH (KEY INTERLOCKED)

Step 7 Check accessory capability on page 5-41 before proceeding. (B2N, V2N & V3N ONLY) (ALL EXCEPT B2N) PLEASE SPECIFY KEY OUT
IN WHICH POSITIONS

D i – ACCESSORIES STANDARD

5
Refer page 5 - 34 – 5 - 35 TC (TERMINAL COVERS) TS (TERMINAL SHIELD) ST (SPADE TERMINAL)
Step 8 If purchasing escutcheon only, select the plate size.
(B2N & VN100 ONLY) (VN40 & VN63 ONLY) (V2N ONLY)

6
Step 9 Fill in the header plate details as required. D ii– ACCESSORIES SPECIAL
Refer page 5 - 36 – 5 - 39 R1 R2L R2R R2
SPRING RETURN
(V2N & V3N ONLY)

Step 10 Note there are two clock-face diagrams. Plate A diagram IP 65 WEATHERPROOF KIT
(PANEL MOUNT ONLY)
WPK
DOOR COUPLING WITH INTERLOCK
(AVAILABLE ON ALL SWITCHES)
TKTV

should be filled in when ordering a switch that would EXTENDED TERMINALS


AT
PROTECTIVE BOOT (IP 54)
PB

operate at 30° or 60° switching angles. Plate B diagram (VN40-VN100 ONLY) (B2N-VN63 ONLY)

EXS
should be filled in when ordering a switch that would EXTENSION SHAFT
(PLEASE PROVIDE LENGTH FROM BASE OF
SWITCH TO TOP PANEL) mm
GOLD CONTACTS
(V2N ONLY)

operate at 45° or 90°. The number of squares alongside AUXILIARY CONTACTS (PLEASE INDICATE SWITCHING CONFIGURATION
(FOR SWITCHES ABOVE 40 A ONLY) FOR AUXILIARY CONTACT IN YOUR CAM DIAGRAM)

each position on the clock-face represents one character. (QTY) (RATING Amps)

This is a guide based on the recommended font size. For 7


E – engraving and switching positions
other options including font size variation or symbols 48 65 72 96 125

refer NHP.
If ordering face plate only, please tick appropriate size:
V1N,
mm mm
V3N_C
8 mm
V3N_P,
mm
VN63,
mm
VN150,
B2N, VN40 VN100 VN250
V2N

Using the squares surrounding the clockface diagrams below, insert engraving requirements.
Step 11 Shade in the squares under the switching positions to Plate ‘A’ suits 30 ° + 60 ° switching. Plate ‘B’ suits 45 ° + 90 ° switching .

Header plate
indicate which contacts are to be closed at that position. (HP)
if required
9

Example A Contacts between terminals 1 and 2 are


Plate A Plate B
open in switching position 1 (OFF).
10
Example B Contacts between terminals 3 and 4 are
closed in position 3 and remain closed when switch is
turned to position 4.
✔ Tick box to choose switching angle if crutial

Example C Terminals 2, 4 and 6 are bridged. F – CONTACT CONFIGURA


CONFIGURATION
TION
Using the legend, shade in the squares
the squar es to represent
repr esen t in which
which position contacts
contacts need
need to close. Refer to page
page 55 --42
42for
of r example.
example .

11
RUN

Example D Contacts between terminals 7 and 8 are


OFF

JOG
ON

C
closed in switching position 2 (ON). When actuator is A
released, it springs back to switching position 1 (OFF). B
D
Example E Contacts between terminals 9 and 10 are
closed in switching position 1. As the switch is turned E
from switching position 1 to switching position 2 the
contacts between terminals 11 and 12 also close. At this
point our second circuit makes before our first circuit
breaks. When the switch reaches switching position 2,
contacts between terminals 9 and 10 open. This is
referred to as ‘Make before break’ or ‘overlapping
contacts’.

5 - 40
‘Special’ locally assembled cam switches
Accessory compatibility
The following tables can be used as a guide to determine which accessory options can be fitted to your special switch.

How to choose an Elektra switch accessory


Proceed through Steps 1 to 3 to determine;
1 Which accessory can be fitted, depending on the switch size
2 Which accessory can be fitted, depending on the mounting method
3 Which accessories can be combined on the same switch

Step 1
Accessory suitability to switch types
Not all accessory options can be fitted to the range of switch sizes.
Refer to the table below to identify which accessories can be fitted.

Description Cat. No. R TKTV EXS WPK Z ZSH 3S/5S ES 3SD 2KS PB TC TS ST AT HP
Switch size V1N ✔ ✔ ✔ ✔ ✔ ✔
B2N ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔
V2N ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔
V3N ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔
VN40
VN63
VN100





























5
VN150 ✔ ✔ ✔ ✔ ✔ ✔
VN250 ✔ ✔ ✔ ✔ ✔ ✔

Step 2
Accessory suitability to switch mounting types
Depending on the mounting method of the switch, not all accessory options can be utilised.
Refer to the table below to identify which accessories can be fitted.

Description Cat. No. R TKTV EXS WPK Z ZSH 3S/5S ES 3SD 2KS PB TC TS ST AT HP
Panel mount (P) ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔
Single hole mount (C) ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔
Base mount (B) ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔
Large enclosed (LE) ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔
Compact enclosed (E) ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔

Step 3
Accessory compatibility cross-reference
Elektra cam switches can be fitted with a large variety of different accessory options. In certain cases accessories cannot be
combined on the same switch. To determine which accessories can be used together on the same switch, refer to the table below.

Description Cat. No. R TKTV EXS WPK Z ZSH 3S/5S ES 3SD 2KS PB TC TS ST AT HP
Spring return (R) ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔
Door interlock (TKTV) ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔
Extension shaft (EXS) ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔
Weatherproof seal (WPK) ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔
Key switching (Z) ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔
Key interlock (ZSH) ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔
Interlocking plate (3S/5S) ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔
Single lock plate (ES) ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔
Circular lock plate (3SD) ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔
Lockable knob (2KS) ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔
Protective boot (PB) ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔
Terminal cover (TC) ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔
Terminal shield (TS) ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔
Spade terminal (ST) ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔
Extended terminal (AT) ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔
Header plate (HP) ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔

5 - 41
Elektra ‘Specials’ order form
When completed, fax form with wiring diagram and order number to your nearest NHP branch or representative.
THIS SIDE MUST BE COMPLETED
To:
Name:
ELECTRICAL ENGINEERING PRODUCTS PTY. LTD.
Company: A.B.N. 84 004 304 812
At: ie: (Insert branch)
Address:

Phone No.:

Order No. Date: _____/_____/_____ Quantity: Date required: ____/____/____

A – SWITCH TYPE & RATING


Refer page 5 - 25
EXISTING SWITCH NUMBER

QUANTITY
AMPS

5 B – MOUNTING
Refer page 5 -25 SINGLE HOLE (C) PANEL (P) BASE (B) ENCLOSED (LE)

(V2N & V3N ONLY)

C i – HANDLE AND PLATE STANDARD


Refer pages 5 - 34 – 5 - 35 STD 3SD ES 3S 5S 2KS

(OFF/ON ONLY)

C ii – HANDLE AND PLATE SPECIAL


Refer page 5 - 39 Z (KEY OPERATED) ZSH (KEY INTERLOCKED)

(B2N, V2N & V3N ONLY) (ALL EXCEPT B2N) PLEASE SPECIFY KEY OUT
IN WHICH POSITIONS

D i – ACCESSORIES STANDARD
Refer pages 5 - 34 – 5 - 35 TC (TERMINAL COVERS) TS (TERMINAL SHIELD) ST (SPADE TERMINAL)

(B2N & VN100 ONLY) (VN40 & VN63 ONLY) (V2N ONLY)

D ii– ACCESSORIES SPECIAL


Refer pages 5 - 36 – 5 - 39 R1 R2L R2R R2
SPRING RETURN
(V2N & V3N ONLY)

WPK TKTV
IP 65 WEATHERPROOF KIT DOOR COUPLING WITH INTERLOCK
(PANEL MOUNT ONLY) (AVAILABLE ON ALL SWITCHES)

AT PB
EXTENDED TERMINALS PROTECTIVE BOOT (IP 54)
(VN40-VN100 ONLY) (B2N-VN63 ONLY)

EXS
EXTENSION SHAFT GOLD CONTACTS
(PLEASE PROVIDE LENGTH FROM BASE OF (V2N ONLY)
SWITCH TO TOP PANEL) mm

AUXILIARY CONTACTS (PLEASE INDICATE SWITCHING CONFIGURATION


(FOR SWITCHES ABOVE 40 A ONLY) FOR AUXILIARY CONTACT IN YOUR CAM DIAGRAM)
(QTY) (RATING Amps)

5 - 42
Elektra ‘Specials’ order form
COMPLETE THIS SIDE or PROVIDE WIRING DIAGRAM

E – ENGRAVING AND SWITCHING POSITIONS

If ordering face plate only, please tick appropriate size: 48 65 72 96 125


mm mm mm mm mm
V1N, V3N_C V3N_P, VN63, VN150,
B2N, VN40 VN100 VN250
V2N
Using the squares surrounding the clockface diagrams below, insert engraving requirements.
Plate ‘A’ suits 30 ° + 60 ° switching. Plate ‘B’ suits 45 ° + 90 ° switching .
Header plate
(HP)
if required

Plate A Plate B

✔ Tick box to choose


switching angle if crucial

F – CONTACT CONFIGURATION
Using the legend, shade in the squares to represent in which position contacts need to close. Refer to page 5 - 40 for example.
RUN
JOG
OFF

ON

5 - 43
Dimensions for Elektra cam switches
12 amp to 250 amp AC 1

Number of contact chambers L (mm)


Switch
Model 1 2 3 4 5 6 7 8
V1N_P 28 37 46 55 64 73 82 91
B2N_P 33 45 57 69 - - - -
B2N_C 54 66 78 90 - - - -
V2N_P 33 45 57 69 81 93 105 117
V2N_C 54 66 78 90 102 114 126 138
V3N_P 34 47 60 73 86 99 112 125
V3N_C 55 68 81 94 107 120 133 146
VN40 44 60 76 92 108 124 140 156
VN63 49 68 86 105 123 142 160 179
VN100 57 81 105 129 153 177 201 225
VN150 77 108 139 170 201 232 263 294
VN250 77 108 139 170 201 232 263 294
5 - 44
Elektra Main switches
with undervoltage release
Protection
Automatic restart of a machine can cause a dangerous situation, either with damage to the machine, work
against
in progress or to the operator of the machinery. The automatic start-up of machinery after a power failure,
auto-restart and subsequent restoration of power, can be safely avoided.
after power
failure The Elektra S-series main switch has an undervoltage release facility. In the instance of a power failure the
undervoltage release coil returns the switch to the OFF position, thereby preventing automatic start-up of
machinery on restoration of the power supply.

The range
Current ratings: 25 A, 40 A, 63 A and 80 A
Coil voltage: 240 V and 415 V, 50 Hz

Panel mount
• Ratings - 25 … 80 A
11 … 45 kW
• Control coil - 240 V or 415 V

Panel or door mount

Base mount
• Ratings - 25 … 80 A
11 … 45 kW
• Control coil - 240 V or 415 V

Base or DIN rail mount

5 - 45
Elektra Main switches
with undervoltage release

Highly visible Red/Yellow handle, facilitates up to 3 padlocks

Ith AC 23 Panel mount Base mount 1)


A kW Cat. No. Price $ Cat. No. Price $
Operating voltage 415 V, coil voltage 240 V, 50 Hz
25 11 S1 011/HS-F3-D-RG S1 011/HS-NF3-D-RG
40 22 S3N 011/HS-F3-D-RG S3N 011/HS-NF3-D-RG
63 30 S4N 011/HS-F3-D-RG S4N 011/HS-NF3-D-RG
80 45 S5N 011/HS-F4-D-RG S5N 011/HS-EF4-D-RG

5 Operating voltage 415 V, coil voltage 415 V, 50 Hz


25 11 S1 013/HS-F3-D-RG S1 013/HS-NF3-D-RG
40 22 S3N 013/HS-F3-D-RG S3N 013/HS-NF3-D-RG
63 30 S4N 013/HS-F3-D-RG S4N 013/HS-NF3-D-RG
80 45 S5N 013/HS-F4-D-RG S5N 013/HS-EF4-D-RG
For control line transformer coil voltage 240 V, 50 Hz secondary
25 11 S1 024/HS-F3-D-RG S1 024/HS-NF3-D-RG

1
Notes: ) Base or DIN rail mount.
2
) After removing the connection (14-D2), a switching element (N/C) can be connected e.g. Emergency Off
pushbutton.
Available on indent only.

240 V coil 415 V coil


2 2
) )

011 013

024

Price Schedule ‘B2’


5 - 46 GST not included
Elektra Foot switches

Elektra FD series foot switches have been developed for high mechanical and electrical endurance.
Foot switches are used in many industrial applications including process machines, CNC machines,
cranes and lathes, whenever hands-free operation is required.

Elektra foot switches employ two switching concepts:


Latched (progressive) switching: When the pedal is pressed, switching contacts close and remain closed
Enclosure with flat
when the pedal is released. When the pedal is pressed again, the contacts re-open.
cover
Momentary switching: When the pedal is pressed, switching contacts close so long as the pedal is
pressed. When the pedal is released the contacts open again.

Elektra foot switches are available with a standard flat cover, a high cover or with a
safety cover.
Flat cover: This is supplied on foot switches with a maximum of 2 contacts (1 chamber).
For example 1 NO + 1 NC or 2 pole on-off switches in either ‘latched’ or ‘momentary’ switching.

Enclosure with high High cover: This is supplied on foot switches with a maximum of 8 contacts (4 chambers),
cover possible in ‘latched’ or ‘momentary’ switching as control and motor switches.

Safety cover: This optional version protects against unintentional operation by falling objects.
The safety cover is available on foot switches with a maximum of 8 contacts (4 chambers).
5
Display window
All foot switches are available with or without a viewing window.
The viewing window provides indication of the switch position.

Pedal lock
All single pedal foot switches, with or without safety cover, can be fitted with a pedal lock.
Enclosure with safety This feature requires a foot to fully cover the pedal to allow the pedal to be operated.
cover

Technical data
Insulation voltage 690 V
Impulse voltage 6 kV

IP 65
Cable cross section 1-4 mm2
tion Terminal screw size M4
protec
Short circuit protection, maximum fuse size 25 A

Switching capacity, EN 60947-3


AC 21, 690 V 25 A
AC 23, 440 V 7.5 kW
AC 3, 440 V 5.5 kW
AC 4, 440 V 2.2 kW
AC 15, 440 V 4A

Mechanical endurance (number of operations)


Latched 3 x 105
Momentary 1 x 106

Ambient temperature - 15 °C to + 60 °C

5 - 47
Elektra Foot switches
Ordering information
One pedal motor isolators (on-off)
One pedal motor isolators can be purchased with options such as locking lever for safety, and window to provide visible contact
status. Each of these options are available with or without safety cover. Models available include 2 pole and 3 pole switches with
contacts that latch (remain closed until re-pressed) or momentary (open and close instantly with foot motion).

Rating Standard With safety cover


Circuit Ith (A) Cat. No. Price $ Cat. No. Price $
25 FD A2U-G FD A2U-GU
FD A2U-GPV FD A2U-GUPV
With lever With lever
FD A2U-GA FD A2U-GUA
2 pole latched
With window With window
FD A2U-GA FD AU-G FD AU-GU
25
FD AU-GPV FD AU-GUPV
With lever With lever
FD AU-GA FD AU-GUA
3 pole latched With window With window

5 25 FD A2T-G
FD A2T-GPV
FD A2T-GU
FD A2T-GUPV
FD A2U-GU With lever With lever
FD A2T-GA FD A2T-GUA
2 pole momentary With window With window
25 FD AT-G FD AT-GU
FD AT-GPV FD AT-GUPV
With lever With lever
FD AT-GA FD AT-GUA
FD A2U-GPV 3 pole momentary With window With window
One pedal control switches
One pedal control switches can be purchased with options such as locking lever for safety, and window to provide visible contact
status. Each of these options are available with or without safety cover. Models available include 2 or 4 contact switches with
contacts that latch (remain closed until re-pressed) or momentary (open and close instantly with foot motion).
Rating Standard With safety cover
Circuit Ith (A) Cat. No. Price $ Cat. No. Price $
25 FD 11U-G FD 11U-GU
FD 11U-GPV FD 11U-GUPV
With lever With lever
1 N/O + 1 N/C FD 11U-GA FD 11U-GUA
FD 11U-GA latching With window With window
25 FD 22U-G FD 22U-GU
FD 22U-GPV FD 22U-GUPV
With lever With lever
2 N/O + 2 N/C FD 22U-GA FD 22U-GUA
latching With window With window
25 FD 11T-G FD 11T-GU
FD 11T-GPV FD 11T-GUPV
FD 11U-GU With lever With lever
1 N/O + 1 N/C FD 11T-GA FD 11T-GUA
momentary With window With window
25 FD 22T-G FD 22T-GU
FD 22T-GPV FD 22T-GUPV
With lever With lever
2 N/O + 2 N/C FD 22T-GA FD 22T-GUA
momentary With window With window
FD 11U-GPV

Note: All items available on indent only.


Price Schedule ‘B2’
5 - 48 GST not included
Elektra Foot switches
One pedal - safety foot switch
Operational sequence
1. With pedal (A) in the upper position, the contacts are open, the machine will not operate.
2. When pedal (A) is pushed down, contact point (B) is reached. With the contacts
Pedal Contact closed the machine is now operating.
(A) point (B)
3. In case of danger or emergency, the pedal can be pushed beyond the standard
operational point of the pedal. With this, the contacts open and the machine immediately
stops. The contacts of the foot switch are locked-out preventing the machine from
starting again.
Lock-out 4. The lock-out is manually controlled through the turn knob (C). By turning the knob the
turnknob (C) lock-out releases, returning the foot switch to its normal state.

One pedal - safety motor isolator (on-off)


The one pedal safety motor isolator has an in-built emergency stop feature for safety.
Pushing the pedal beyond its normal point of operation operates the emergency stop feature.

Circuit Rating Ith (A)


25
Cat. No.
FD AR-GU
Price $ 5

One pedal - safety control switch


The one pedal safety control switch has an in-built emergency stop feature for safety. Pushing the pedal
beyond its normal point of operation operates the emergency stop feature.

Circuit Rating Ith (A) Cat. No. Price $


25 FD K1R-GU

25 FD K2R-GU

Machine OFF Machine ON Machine STOP Unlock manually by Machine OFF


switch disabled rotating knob from re-start
disabled position
Price Schedule ‘B2’ Note: All items available on indent only.

GST not included 5 - 49


Elektra Foot switches
Single pedal - with potentiometer control
Single pedal - with potentiometer only
The single pedal potentiometer control foot switch, allows for variable speed control, which is dependent on the amount of
downward pressure placed on the pedal. Potentiometer options include linear or logarithmic type. This option can also be supplied
with a locking lever for safety.

Rating Standard With safety cover


Circuit
Ith (A) Cat. No. Price $ Cat. No. Price $
2.2 FP 2.2KLIN-G FP 2.2KLIN-GU
4.7 FP 4.7KLIN-G FP 4.7KLIN-GU
10 FP 10KLIN-G FP 10KLIN-GU
4.7 FP 4.7KLOG-G FP 4.7KLOG-GU

LIN = linear type potentiometer LOG = logarithmic type potentiometer

Single pedal - with potentiometer and micro - auxiliary


The single pedal potentiometer control foot switch, allows for variable speed control, which is dependent on the amount of
downward pressure placed on the pedal. Potentiometer options include linear or logarithmic type. This option is fitted with a

5 micro-auxiliary which can be used for signalling. This switch can also be supplied with locking lever for safety.

Circuit Rating Standard With safety cover


Ith (A) Cat. No. Price $ Cat. No. Price $
2.2 FP A1/2.2KLIN-G FP A1/2.2KLIN-GU
4.7 FP A1/4.7KLIN-G FP A1/4.7KLIN-GU
10 FP A1/10KLIN-G FP A1/10KLIN-GU
4.7 FP A1/4.7KLOG-G FP A1/4.7KLOG-GU

LIN = linear type potentiometer LOG = logarithmic type potentiometer

Double pedal foot switches


In addition to the double pedal forward-reverse foot switches below, double pedal switches are also available in contact
configurations as detailed in the single pedal types.

Double pedal motor reversing foot switch


The double pedal motor reversing foot switch has two pedals separated by a barrier to prevent both switches being operated by one
foot. This switch is ideal for applications requiring a reversing action of a motor. The switch can be supplied with optional windows
to indicate switching position.

Rating Standard With safety cover


Circuit Ith (A) Cat. No. Price $ Cat. No. Price $
2.2 FD WT-G FD WT-GU
Left Right

Note: All items available on indent only.


Price Schedule ‘B2’
5 - 50 GST not included