Figure 1. Two cycle of Normal heart sound that
include 4 N-gram words Figure 2. Heart sound (a) before and (b) after
preprocessing
To improve the performance of the system and obtain for encoding audio format to MIDI files.
more accurate output, several rules were applied in the
last component of database construction. Prior to the 4. Experiments
storage of a record in the database, a heart disease
category must be selected for each disease, for instance, On this regards, this section presents the evaluation
Systolic Murmur is the relevant category for Aortic process for the proposed system in this paper.
Stenosis problem. Specifically, a comprehensive experimental analysis
using simulation is carried out in order to show the
3.2 MIDI Encoding usefulness of the proposed work. Finally, the results of
experiment are presented and discussed.
MIDI is a popular format in computer-based music
production such as composition, transcription, etc. Size of 4.1. Retrieval Experiments
MIDI files is generally smaller than other music formats.
With wave to MIDI converters, we will be able to In MIDI encoding part we do the experiment on count
generate MIDI data of PCM-based sounds rather easily. It of cycles for measure the accuracy of our system in
extracts acoustical characteristics such as pitch, volume, diagnosis the heart problem. We selected 6 random cases
and duration for converting them into a sequence of notes from each category, as a result we had 8 categories which
for producing music scores. Thus, melodies will be send 48 query from different cases to system in every
translated into chromatic pitches without human step. We started our test with a single cycle queries and
intervention [10]. The quality of MIDI transcribed would then calculate the accuracy with the below metric:
also depend on the algorithm capabilities which are
utilized.
Since the heart sound frequency is between 25-50Hz MIDI Encoding Accuracy = (5)
[11] therefore the encoding component just filtered heart
sound with this frequency and ignore another sounds. In Then we repeated the test until each query contained
other hand the lowest note and highest note that will be 14 cycles. As shown in Figure 4, the best performance is
encode are between C0-C2 (16 Hz-65 Hz). achieved when we use 10-14 cycles for each heart sound
In the first step we needed to select a tool for MIDI record therefore we need at least 10 cycles for each heart
encoder for changing audio files to MIDI format. For this sound case. The experiment was carried out under
objective, 4 MIDI convertors were compared that are Microsoft Windows 7 on a Core2 Duo processor at 3
shown in Figure 3. GHz and 4 GB RAM. Furthermore, 11 records of Normal
Since the heart sound has low frequency and small heart sounds used in the experiment were captured by
duration .Therefore, the tools should be able of accurate means of an electronic digital Littman 3M stethoscope
transcription of these parameters. To achieve this model 4100.
objective we played 30 different pitches in C1 channel
and select Drums Program of YAMAHA Electronic
synthesizer. 100
Accuracy (%)
100 93.33 80
Accuracy (%)
80 63.33
70 60
56.66
60 40
40 20
20
0
0 0 2 4 6 8 10 12 14
Amazing MIDI WIDI Soft Melodyn DIGITAL Ear
Count of Cycles