15 KV URD CABLE
Underground distribution of power for residential and commercial distribution circuits. Used in
single-phase systems direct burial or underground in duct. Consists of compressed aluminum alloy 1350 conductor or compressed
annealed bare copper conductor, triple tandum extruded insulation using a thermosetting semiconducting conductor shield,
tree-retardant cross-linked (TR-XLP), thermosetting semiconducting insulation shield; 1/3 and full coated copper neutral with or
without a jacket.
Specifications: Conforms to AEIC CS5, ICEA S-66-524/NEMA WC-7 Technical Acceptance: REA-U1 Ampacity: See Ampacity
Tables in the National Electric Code, Articles 310, 318, and 501 100% Insulation level is equivalent to .175 mil of Tree-Retardant
Cross-Linked Polyethylene 133% Insulation level is equivalent to .220 mil of Tree-Retardant Cross-Linked Polyethylene
Catalog
No.
Conductor Size
AWG/MCM
Insulation
Overall
Dia (Inches)
Neutral No.
of Wires
AWG
Nom. Weight
Without Jkt
lbs/1000 ft
P01S8
P02S8
P03S8
* 2- 7 STRD
2 - 7 STRD
1/0 - 19 STRD
.68
.68
.76
6 x 14
16 x 14
16 x 12
462
595
873
P04S8
P05S8
P06S8
* 2- 7 STRD
2 - 7 STRD
1/0 - 19 STRD
.78
.78
.85
6 x 14
16 x 14
16 x 12
505
645
920
P07S8
P08S8
P09S8
P10S8
P11S8
P12S8
P13S8
P14S8
P15S8
P16S8
P17S8
P18S8
P19S8
P20S8
2 SOLID
* 2 - 7 STRD
2 - 7 STRD
1/0 SOLID
* 1/0 - 19 STRD
1/0 - 19 STRD
2/0 - 19 STRD
3/0 - 19 STRD
*4/0 - 19 STRD
4/0 - 19 STRD
*350 - 37 STRD
*500 - 37 STRD
* 750 - 61 STRD
* 1000 - 61 STRD
.66
.69
.69
.74
.76
.76
.81
.86
.92
.92
1.08
1.20
1.39
1.54
10 x 14
6 x 14
10 x 14
16 x 14
6 x 14
16 x 14
13 x 12
16 x 12
11 x 14
20 x 12
18 x 14
16 x 12
15 x 10
20 x 10
355
328
372
498
396
510
622
734
594
876
910
1208
1688
2202
P21S8
P22S8
P23S8
P24S8
P25S8
P26S8
P27S8
P28S8
P29S8
P30S8
P31S8
P32S8
P33S8
P34S8
2 SOLID
* 2 - 7 STRD
2 - 7 STRD
1/0 SOLID
* 1/0 - 19 STRD
1/0 - 19 STRD
2/0 - 19 STRD
3/0 - 19 STRD
*4/0 - 19 STRD
4/0 - 19 STRD
*350 - 37 STRD
*500 - 37 STRD
* 750 - 61 STRD
* 1000 - 61 STRD
.75
.78
.78
.82
.85
.85
.90
.95
1.00
1.00
1.17
1.29
1.48
1.63
10 x 14
6 x 14
10 x 14
16 x 14
6 x 14
16 x 14
13 x 12
16 x 12
11 x 14
20 x 12
18 x 14
16 x 12
15 x 10
20 x 10
405
367
420
544
440
557
655
776
655
923
960
1272
1738
2274
CU Content
295
427
677
275
427
677
Metal Content
AL
CU
61
133
62
80
62
133
97
213
99
80
99
213
125
268
158
335
199
146
199
425
329
240
469
335
703
500
936
681
Metal Content
AL
CU
61
133
62
80
62
133
97
213
99
80
99
213
125
268
158
335
199
146
199
425
329
240
469
335
703
500
936
681
Overall Jacket
Nom. Weight
Thickness (Diameter) With Jacket
Mils
Inches
bs/m
50
50
50
1.00
1.00
1.08
574
705
987
50
50
50
1.09
1.09
1.17
616
756
1035
50
50
50
50
50
50
50
50
50
50
50
50
80
80
.95
1.00
1.00
1.04
1.08
1.08
1.13
1.15
1.23
1.23
1.41
1.57
1.86
2.07
467
440
482
612
510
624
737
848
710
985
1060
1395
1940
2495
50
50
50
50
50
50
50
50
50
50
50
50
80
80
1.04
1.09
1.09
1.12
1.17
1.17
1.21
1.26
1.32
1.32
1.50
1.66
1.95
2.16
515
500
530
674
570
689
770
890
771
1032
1110
1442
2290
2590