Vous êtes sur la page 1sur 123

5 Port Solenoid Valve Metal Seal/Rubber Seal

Series
Stacking Manifold
The use of cassette style valves and manifolds makes it easy to increase or decrease the number of stations on a DIN rail. The plug-in type includes two extra valve station connectors. This design makes rewiring unnecessary during manifold expansion. Also, the use of a single part number simplifies the ordering process.

SQ1000/2000
VQC SQ VQ0 VQ4 VQ5 VQZ

Manifold Mounted Type


Valve maintenance is simple and labor time is reduced by a single mounting screw.

Easy Replacement of Clip Type One-touch Fittings


One-touch fittings can be replaced without removing valves.

Built-in Back Pressure Check Valve (Option symbol: B) VQD


Eliminates trouble with back pressure when driving a single acting cylinder or when using an exhaust center type valve, etc.

Connector Entry Direction Can be Changed with a Single Push.


The connector entry direction can be changed from the top to the side by simply pressing the manual release button. It is not necessary to use the manual release button when switching from the side to the top.

Unprecedented High Speed Response and Long Service Life


Model Response time LifeNote)

SQ1000 SQ2000

12 ms or less 200 million cycles 20 ms or less

Note) For metal seal, single type, DC specifications, based on SMC life conditions. For applications which demand high speed, high frequency, long life and a precise response time.

Cylinder Speed Chart


Flow Characteristics Note)
Base mounted Metal seal C [dm3/(sbar)] b Cv Rubber seal C [dm3/(sbar)] b Cv 800 700 600 500 Average speed (mm/s) Series CJ2 6 10 16

Pressure: 0.5 MPa/Load factor: 50%


Bore size (mm) Series CM2 20 25 32 40
Perpendicular, Upward actuation Horizontal actuation

SQ1000

0.63

0.11

0.14

0.80

0.20

0.19

400 300 200 100 0 800 700 600 500

SQ2000

2.4

0.14

0.75

3.1

0.18

0.71

400 300 200 100 0

It is when the cylinder is extending that is meter-out controlled by speed controller which is directly connected with cylinder, and its needle valve with being fully open. The average velocity of the cylinder is what the stroke is divided by the total stroke time. Load factor: ((Load weight x 9.8) /Theoretical force) x 100%

Note) 2 position single, 4/2

5/3 (A/B

R1/R2)

Conditions
Base mounted Tube x Length Series CJ2 Series CM2 Series MB/CA1 TO604 x 1 m AS3001F-06 AN110-01 T0604 x 1 m T1075 x 1 m T1209 x 1 m AS3001F-06 AS4001F-10 AN200-02

SQ1000

Speed controller Silencer Tube x Length

SQ2000

Speed controller Silencer

2-3-1

Series

SQ1000/2000
Precautions 1

Be sure to read before handling. For Safety Instructions and Solenoid Valve Precautions, refer to page 2-9-2.

Manual Override

Warning
Use to switch the main valve.

Push Type (Tool required)


Push down on the manual override button with a small screwdriver until it stops. (Available for all types except 2 position double (Latching).)

Locking Type (Tool required)


Push down completely on the manual override button with a small screwdriver. While down, turn clockwise 90 to lock it. Turn it counterclockwise to release it. (Available for all types except 2 position double (Latching).)

SQ1000

SQ2000

Bore 4

Bore 4.8

SQ1000

SQ2000

(1) (2)
Bore 4

(1) (2)
Bore 4.8

Push Type (Tool required) 2 Position Double (Latching) Type


To lock in set position (Flow path: P A): Turn the manual override clockwise by 180 to mark press down. Valve is now locked in the set condition. (Flow path: P A) To reset (Flow path: P B): Turn manual override counterclockwise to mark and press down. Valve will then be in the reset condition.

Slide Locking Type (Manual type) (SQ2000 only)


The manual override is locked by sliding it all the way to the pilot valve side (ON side) with a small flat head screwdriver or finger. Slide it to the fitting side (OFF side) to release it. In addition, it can also be used as a push type by using a screwdriver, etc., of 2 or less. (Available for all types except 2 position double (Latching).)

SQ1000

SQ2000

(1) (2)
Bore 4

(1) (2)
Bore 4.5

SQ2000
Bore 2

OFF position ON position

<Caution> Do not turn the manual override when it is pushed in, as this may cause damage. The construction is such that the operating force is different on sides A and B.

2-3-2

Series
Precautions 2

SQ1000/2000

Be sure to read before handling. For Safety Instructions and Solenoid Valve Precautions, refer to page 2-9-2.

Light/Surge Voltage Suppressor

Caution
Indicator lights are all positioned on one side for both single solenoid and double solenoid types. For double, 3 position, and 4 position dual 3 port types, 2 colors are used to indicate the energization of A side or B side.

VQC SQ VQ0

SQ1000
Indicator light A: Orange B: Green

SQ2000

Indicator light A: Orange B: Green

Single solenoid type

VQ4 VQ5 VQZ VQD

Single solenoid type Double (latching) type Double (double solenoid) type 3 position/Dual 3 port type Manual override: Orange (A side) Manual override: Green (B side)

Double (latching) type

Double (double solenoid) type

3 position/Dual 3 port type

Manual override: Green (B side) Manual override: Orange (A side)

Single Solenoid Type (SQ1000/2000)


Positive common specifications
()

Double (Double solenoid) Type (SQ1000/2000) 3 Position Type (SQ1000/2000) 4 Position Dual 3 Port Type (SQ1000/2000)
Positive common specifications
()

SOL. A + COM

SOL. A

Negative common specifications


(+)

COM (+) SOL. B ()

SOL. A COM

Negative common specifications


(+)

Double (Latching) Type (SQ1000/2000)


Positive common specifications
A () Set
Simultaneous energization protection circuit

SOL. A COM () SOL. B

C (+) COM

SOL.

(+)

B () Reset

Negative common specifications


A (+) Set
Simultaneous energization protection circuit

C () COM

SOL.

B (+) Reset

2-3-3

Series

SQ1000/2000
Precautions 3

Be sure to read before handling. For Safety Instructions and Solenoid Valve Precautions, refer to page 2-9-2.

2 Position Double (Latching solenoid) Type

Mounting and Removal of Manifold with DIN Rail

Caution
Within the double type, a latching (with self holding mechanism) solenoid type is available in addition to the conventional double solenoid. The appearance is the same as the single solenoid. However, the construction allows the armature inside the solenoid to hold the A side ON position and B side ON position during momentary energization (20 ms or longer). The operating method and functions are the same as the conventional double solenoid type. <Special precautions for latching solenoid> 1. Use in a circuit that does not have simultaneous energization of ON and OFF signals. 2. To operate with momentary energization, the energized time should be 20 ms or longer. 3. Although there is no problem for normal operations and environments, do not operate in an environment with vibration (3 G or more) or strong magnetic field. 4. This valve is shipped with the armature inside the solenoid holding the B side ON position (Reset). However, energize to conform whether it is holding the A side ON position or B side ON position before operation. 5. To operate for an extended time, use SQ 1 2 30 ---X11 41 2 with energy savign circuit.

Caution
Removing Manifold from DIN Rail
(1) Loosen the end plate clamping screws on both sides until

they turn freely. (The screws do not come out.)


(2) Remove the manifold from the DIN rail by lifting it from the

solenoid cover side.


(1)
Clamping screw Solenoid cover

(2)
End plate DIN rail clasp

When a manifold contains a large number of stations and is difficult to remove all at once, separate the manifold into several sections before removing it.

Mounting and Removal of Valves

Mounting Manifold on DIN Rail


The procedure is the reverse of that above. After tightening the clamping screw on one side, push on the opposite end plate so that there are no gaps between the manifold blockes and then tighten the other clamping screw.
End plate

Caution
Mounting
Insert the hook of the valve into the fitting on the manifold block, then push the valve down into place and tighten the mounting screw. Tighten the screw with the appropriate tightening torque shown below.
SQ1000 SQ2000 0.17 to 0.23 Nm 0.25 to 0.35 Nm

(3) Tighten
2.PUSH 1.TURN 2.PUSH 1.TURN

(2) Push together

When pushing the valve down, press it on the area near the manual override. Be careful not to push the solenoid cover.
(1) Tightening clamping screw
Manual override Solenoid cover Connector Mounting screw Proper tightening torque: 0.8 to 1.0 Nm (SQ1000, SQ2000) DIN rail clasps

(2)

Confirm that the DIN rail clasps are securely hooked into the DIN rail.
Fitting Hook

(1)
Hook Fitting

(3)

Removing
Loosen the valve mounting screw, lift the valve from the solenoid cover side and remove it by sliding it in the direction of arrow (3). If it is difficult to loosen the screw, loosen it while pressing the valve gently on the area near the manual override.

2-3-4

Series
Precautions 4

SQ1000/2000

Be sure to read before handling. For Safety Instructions and Solenoid Valve Precautions, refer to page 2-9-2.

Replacement of Cylinder Port Fittings

Built-in Silencer Replacement Element

Caution
The cylinder port fittings are a cassette for easy replacement. Fittings are secured with a clip that is inserted from the top side of the valve. Remove the clip with a flat head screwdriver, etc., to replace the fittings. To mount a fitting, insert the fitting assembly until it stops and reinsert the clip to its designated position.
Fitting assembly part no. SQ1000 SQ2000 VVQ1000-50A-C3 3.2 VVQ1000-50A-C4 VVQ1000-51A-C4 4 VVQ1000-51A-C6 VVQ1000-50A-C6 6 VVQ1000-51A-C8 8 Part numbers above are for one fitting; however, order them in 10 piece units. Applicable tubing O.D. (mm)

Caution
A filter element is built into the manifold base end plate. When the element becomes dirty and clogged, this will cause trouble such as a drop in the cylinder speed, etc. Therefore, replace the element regularly.

VQC SQ

Element part no.


Type Element part no. SQ1000 SQ2000 SSQ2000-SE Built-in silencer SSQ1000-SE direct exhaust (-S) Part numbers above are for a set of ten elements.

VQ0 VQ4 VQ5 VQZ VQD

Caution
Use caution that O-rings must be free from scratches and dust. Otherwise, air leakage may result.
Element

Tightening torque 0.5 to 0.7 Nm (SQ1000) 0.8 to 1.0 Nm (SQ2000)

Clip

Fitting assembly

To replace an element, remove the cover on the top side of the end plate and remove the old element with a flat head screwdriver, etc.

How to Calculate the Flow Rate


For obtaining the flow rate, refer to pages 2-1-8 to 2-1-11.

2-3-5

For details about certified products conforming to international standards, visit us at www.smcworld.com.

Series SQ1000

Plug-in Unit
How to Order Manifold

SS5Q13
01 24
Note)

08 FD2

D
Option
Nil None DIN rail length specified Back pressure check valve Special wiring specifications (Except double wiring) With name plate (Side ported only) External pilot specifications Built-in silencer, direct exhaust

Stations
1 station 24 stations

Note) The maximum number of stations depends on the type of electrical entries.

02 to 24 (1) B K (2) N R S

Manifold mounting
D E
DIN rail mounting style Direct mounting style

Note 1) Specify DIN rail length with D at the end. (Enter the number of stations inside .) Example: -D08 Note 2) Standard wiring specifications are for double wiring. Indicate wiring specifications for single wiring or mixed single and double wiring, or when exceeding the standard maximum number of stations. (Except L kit.) Note 3) For specifying two or more options, enter them alphabetically. Example: -BKN
(2) Max. number of stations for Max. number special wiring of solenoids specifications

Electrical entry
Kit type Lead wire connector location
U side

Cable specifications D-sub connector (25P) kit, without cable

Station

F kit
D-sub connector kit D side

P kit

Flat ribbon cable connector kit

( 26P ) 20P

FD0 FD1 FD2 FD3 PD0 PD1 PD2 PD3 PDC

D side

D-sub connector (25P) kit, with 1.5 m cable D-sub connector (25P) kit, with 3.0 m cable D-sub connector (25P) kit, with 5.0 m cable Flat ribbon cable (26P) kit, without cable Flat ribbon cable (26P) kit, with 1.5 m cable Flat ribbon cable (26P) kit, with 3.0 m cable Flat ribbon cable (26P) kit, with 5.0 m cable Flat ribbon cable (20P) kit, without cable

1 to 12 stations

24 stations

24

D side

(1)

1 to 12 stations

24 stations

24

1 to 9 stations

18 stations

18

J kit
JD0
Flat ribbon cable (20P) (PC Wiring System compatible)

D side

Flat ribbon cable (20P) PC Wiring System compatible

1 to 8 stations

16 stations

16

L kit

Lead wire kit

S kit

Serial transmission kit

LD0 LU0 LD1 LU1 LD2 LU2 SDF SDH SDJ1 SDJ2 SDQ SDR1 SDR2 SDV

D side U side D side U side D side U side

Lead wire kit with 0.6 m cable Lead wire kit, with 1.5 m cable Lead wire kit, with 3.0 m cable NKE Corp.: Uni-wire System NKE Corp.: Uni-wire H System SUNX Corp.: S-LINK System (16 output points) SUNX Corp.: S-LINK System (8 output points) DeviceNet, CompoBus/D (OMRON Corp.) OMRON Corp.: CompoBus/S System (16 output points) OMRON Corp.: CompoBus/S System (8 output points) Mitsubishi Electric Corp.: CC-LINK System 1 to 8 stations 1 to 4 stations 1 to 8 stations 1 to 4 stations 1 to 8 stations 16 stations 8 stations 16 stations 8 stations 16 stations 16 8 16 8 16 1 to 12 stations

D side

Note 1) Separately order the 20P type cable assembly for the P kit. Note 2) The maximum number of stations should not be more than the maximum number of solenoids. (The number of solenoids are counted as: 1 for single solenoids and 2 for type 3P and 4P double solenoids.)

2-3-6

Plug-in Unit

Series

SQ1000

How to Order Valves

SQ1 1 3 0
Type of actuation
2 position single
(A)(B) 4 2

C6
With/Without manifold block
Nil Without manifold block M With manifold block MB With manifold block, built-in back pressure check valve

513 (R1)(P)(R2)

2 position double (Latching)


(A)(B) 4 2 (A)(B) 4 2

VQC SQ
Lead wire is not included. Lead wire is not included. When ordering with manifolds When only valves are required.

513 (R1)(P)(R2)

513 (R1)(P)(R2)

Metal seal

Rubber seal

2 position double (Double solenoid) (1)


(A)(B) 4 2 (A)(B) 4 2

VQ0 VQ4

513 (R1)(P)(R2)

513 (R1)(P)(R2)

Metal seal

Rubber seal

For adding stations

3 position closed center

VQ5 VQZ

(A)(B) 4 2

513 (R1)(P)(R2)

3 position exhaust center

Port plug mounting port


Nil None Port 4(A) Port 2(B)

(A)(B) 4 2

VQD

513 (R1)(P)(R2)

3 position pressure center

A B

(A)(B) 4 2

513 (R1)(P)(R2)

Cylinder port
C3 C4 C6 M5 L3 L4 L6 L5 One-touch fitting for 3.2 One-touch fitting for 4 One-touch fitting for 6
M5 thread One-touch fitting for 3.2 One-touch fitting for 4 One-touch fitting for 6 M5 thread
Note) Can be changed to side ported configuration. Note)

4 position dual 3 port valve


(2)
(A) 4 (B) 2

A
5 (R1) 1 (P) 3 (R2)

Side ported

N.C.
(2)
(A) 4

N.C.
(B) 2

4 position dual 3 port valve

5 (R1)

1 (P)

3 (R2)

Top ported

N.O.
(2)
(A) 4

N.O.
(B) 2

4 position dual 3 port valve

5 (R1)

1 (P)

3 (R2)

Manual override
Nil Non-locking push type (Tool required)

N.C.

N.O.

B Note)
Locking type (Tool required)

Note 1) For double solenoid specification, the function symbol below is D. Note 2) Only rubber seal types are applicable.

Seal
0 1
Metal seal Rubber seal

Function
Nil Standard type (1.0 W DC) 2 position double (Double solenoid specifications)
(1)

Note) Except double (latching) type.

D K N (1) Y R (2)

High pressure type (1.0 MPa, 1.0 W DC) [Applicable to metal seal only] Negative COM Low wattage type (0.5 W DC) External pilot specifications

Coil voltage
5 6
24 VDC 12 VDC
Note) Light/Surge voltage suppressor is built-in.

Note 1) Except double (latching) type. Note 2) Except dual 3 port valves. Note 3) When two or more symbols are specified, indicate them alphabetically.

2-3-7

Series

SQ1000
P. 2-3-44 Individual SUP/EXH spacer P. 2-3-45 Name plate (-N) P. 2-3-47 External pilot P. 2-3-48

Manifold Option
Blanking plate

SSQ1000-10A-3

SSQ1000-PR1-3- C6 L6

SSQ1000-N3-n

specifications (-R)
External pilot port

SUP/EXH block

P. 2-3-44 SUP block plate

P. 2-3-46 Blanking plug

P. 2-3-47 Dual flow fitting

P. 2-3-48

SSQ1000-PR-3-C8 (-S)

SSQ1000-B-P
R P

KQ2P-23/04/06/08

SSQ1000-52A- C8 N9

D side

U side

Individual SUP spacer P. 2-3-44 EXH block plate

P. 2-3-46 Port plug

P. 2-3-47 Silencer

P. 2-3-48

SSQ1000-P-3- C6 L6

SSQ1000-B-R
R P

VVQZ100-CP

(For EXH port)

D side

SM

AN

20

U side

Individual EXH spacer P. 2-3-45 Back pressure check valve (-B) SSQ1000-R-3-C6
L6

P. 2-3-46 Built-in silencer (-S) P. 2-3-47 Special wiring

P. 2-3-49
Terminal no. SOL.A SOL.A SOL.A SOL.A SOL.A SOL.B SOL.A SOL.B SOL.A SOL.B SOL.A SOL.B COM. 1 () 14 () 2 () 15 () 3 () 16 () 4 () 17 () 5 () 18 () 6 () 19 () 13 (+)

specifications (-K)
D-sub connector 1 station 2 stations 3 stations 1 14 4 stations 2
15 16 17 18 19 20 21 22 23 24 25 3 4 5 6 7 8 9 10 11 12 13

SSQ1000-BP

5 stations 6 stations 7 stations 8 stations

Connector terminal no.

Although the standard products come with double wiring, mixed single and double wiring is available upon request.

2-3-8

Plug-in Unit How to Order Manifold Assembly (Example)


Example: D-sub connector kit, with cable (3 m)
2 position single (24 VDC) SQ1130-5-C6 (4 sets) 2 position double (Latching) (24 VDC) SQ1230-5-C6 (4 sets)

Series

SQ1000

3m

1 S on tati s

Blanking plate SSQ1000-10A-3 (1 set)


sid e

VQC SQ VQ0 VQ4 VQ5

S Q 10 00 -1 S Q 12 30 -5 S Q 12 30 -5 S Q 12 30 -5 S Q 12 30 -5 -C 6 -C 6 -C 6 0A -3

S Q 11 30 -5

-C 6

S Q 11 30 -5 S Q 11 30 -5 S Q 11 30 -5 -C 6 -C 6 -C 6

-C 6

D-sub connector cable AXT100-DS25-030 Cylinder port fitting C6: One-touch fitting for 6 Manifold base (9 stations) SS5Q13-09FD2-D

VQZ VQD

Ds

ide

F kit (D-sub connector kit)

SS5Q13-09FD2-D 1 set (F kit 9 station manifold base) SQ1130-5-C6 4 sets (2 position single) SQ1230-5-C6 4 sets (2 position double [latching]) SSQ1000-10A-3 1 set (Blanking plate)
The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc. Add the valve and option part numbers in order starting from the first station on the D side. When entry of part numbers becomes complicated, indicate on the manifold specification sheet.

2-3-9

Series
Model
Series

SQ1000
Flow characteristic Model Metal seal Rubber seal Metal seal Rubber seal Metal seal Rubber seal Metal seal Rubber seal Metal seal Rubber seal Metal seal Rubber seal Rubber seal 1 C [dm3/(sbar)] 4/2 (P b 0.10 0.20 0.10 0.20 0.10 0.20 0.12 0.20 0.12 0.20 0.12 0.21 0.28 A/B) Cv 0.14 0.19 0.14 0.19 0.14 0.19 0.14 0.15 0.14 0.15 0.14 0.19 0.15 4/2 5/3 (A/B C [dm3/(sbar)] b 0.63 0.80 0.63 0.80 0.63 0.80 0.63 0.58 0.60 0.80 0.63 0.59 0.59 0.11 0.20 0.11 0.20 0.11 0.20 0.11 0.26 0.14 0.20 0.14 0.20 0.28 R1/R2) Cv 0.14 0.19 0.14 0.19 0.14 0.19 0.14 0.16 0.14 0.19 0.14 0.14 0.15 Response time (ms) Standard: 1W 12 or less 15 or less 15 or less 20 or less 10 or less 15 or less 20 or less 25 or less 20 or less 25 or less 20 or less 25 or less 25 or less
(2)

Valve Specifications

Number of solenoids

Low wattage 15 or less 20 or less 13 or less 20 or less 26 or less 33 or less 26 or less 33 or less 26 or less 33 or less 33 or less

Weight (g) 80 80 80 80 95 95 100 100 100 100 100 100 95

Single
2 position

SQ1130 SQ1131 SQ1230 SQ1231 SQ1230D SQ1231D SQ1330 SQ1331 SQ1430 SQ1431 SQ1530 SQ1531 SQ1 31
A B C

0.62 0.79 0.62 0.79 0.62 0.79 0.58 0.64 0.58 0.64 0.62 0.79 0.59

Double (Latching) Double (Double solenoid) Closed center Exhaust center Pressure center

SQ1000
3 position 4 position

Dual 3 port valve

Note 1) Values for the cylinder port size of C6. Note 2) Based on JIS B 8375-1981. (Values with a supply pressure of 0.5 MPa and light/surge voltage suppressor. Values fluctuate depending on the pressure and air quality.)

Specifications
Valve construction Fluid Maximum operating pressure Valve specifications Single Double (Latching) Min. operating Double (Double solenoid) pressure 3 position 4 position Ambient and fluid temp. Lubrication Pilot valve manual override Vibration/Impact resistance (2) Protection structure Solenoid specifications
51 3 (R1)(P)(R2)

Metal seal Air/Inert gas

Rubber seal

0.7 MPa (High pressure type: 1.0 MPa) (3) 0.1 MPa 0.18 MPa 0.1 MPa 0.1 MPa 10 to 50C
(1)

0.15 MPa 0.18 MPa 0.1 MPa 0.2 MPa 0.15 MPa

JIS Symbol
2 position single
(A) (B) 4 2

Not required Push type/Locking type (Tool required) 30/150 m/s2 Dust tight 12 VDC, 24 VDC 10% of rated voltage Equivalent to class B 24 VDC 12 VDC 1 W DC (42 mA), 0.5 W DC (21 mA) 1 W DC (83 mA), 0.5 W DC (42 mA)
(4) (4)

Coil rated voltage Allowable voltage fluctuation Coil insulation type Power consumption (Current)

2 position double (Latching)


(A)(B) 4 2 (A)(B) 4 2

51 3 (R1)(P)(R2)

51 3 (R1)(P)(R2)

Metal seal
(A)(B) 4 2

Rubber seal
(A)(B) 4 2

2 position double (Double solenoid)

51 3 (R1)(P)(R2)

51 3 (R1)(P)(R2)

Metal seal

Rubber seal

Note 1) Use dry air to prevent condensation when operating at low temperatures. Note 2) Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 2000 Hz. Test was performed at both energized and de-energized states in the axial direction and at the right angles to the main valve and armature. (Values at the initial period) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and deenergized states every once for each condition. (Values at the initial period) Note 3) Metal seal type only. [Except double (latching) type.] Note 4) Values for the low wattage (0.5 W) specifications.

3 position closed center


(A)(B) 4 2

3 position pressure center


(A)(B) 4 2

4 position dual 3 port valve (B)


4 2

5 51 3 (R1)(P)(R2) 51 3 (R1)(P)(R2)

3 1

N.O.

N.O.

3 position exhaust center


(A)(B) 4 2

4 position dual 3 port valve (A)


4 2

4 position dual 3 port valve (C)


4 2

5 5 1 3 (R1)(P)(R2) 1

5 1

N.C.

N.C.

N.C.

N.O.

2-3-10

Plug-in Unit Manifold Specifications


Porting specifications Base model 1(P), 3(R) Port size
Port location
(1)

Series

SQ1000
(3) (4) (4)

4(A), 2(B) Port size C3 (For 3.2) C4 (For 4) C6 (For 6) M5 (M5 thread) L3 (For 3.2) L4 (For 4) L6 (For 6) L5 (M5 thread)

Applicable solenoid valve

Type of connection

Applicable station

5 station weight (g) 420 420 420 460 475

1 station weight (g) 20 20 20 35 20

F kit: D-sub connector P kit: Flat ribbon cable SQ1 30 SQ1 31 J kit: Flat ribbon cable PC Wiring System compatible L kit: Lead wire S kit: Serial transmission 26P 20P

1 to 12 stations 1 to 12 stations 1 to 9 stations 1 to 8 stations 1 to 12 stations 1 to 8 stations

SS5Q13-

C8 (For 8) Option Built-in silencer, direct exhaust

Side

VQC SQ VQ0 VQ4 VQ5 VQZ VQD

Top

(2)

Note 1) One-touch fittings in inch sizes are also available. For details, refer to page 2-3-56. Note 2) Can be changed to side ported configuration. Note 3) An optional specification for special wiring is available to increase the maximum number of stations. Refer to page 2-3-54 for details. Note 4) Except valves. For valve weight, refer to page 2-3-10.

4(A), 2(B) port 3(R) port 1(P) port 25P 26P/20P (P kit) 20P (J kit)

F kit

P kit J kit

L kit

S kit

2-3-11

Series

SQ1000
Manifold Specifications
Series Port location Porting specifications Port size 1(P), 3(R) 4(A), 2(B) C8 Maximum number of stations

Kit (D-sub connector kit)

Simplification and labor savings for wiring work can be achieved by using a D-sub connector for the electrical connection. Using connector for flat ribbon cable (25P) conforming to MIL standard permits the use of connectors put on the market and gives a wide interchangeability. Top or side entry for the connector can be changed freely, allowing later changes according to the mounting space.

SQ1000

Side, Top

12 stations C3, C4, C6, M5 (24 as an option)

D-sub Connector (25 pins)


Us ide

Cable assembly
015 AXT100-DS25- 030 050 D-sub connector cable assemblies can be ordered with manifolds. Refer to manifold ordering.
ide

3 12

ta s

tion

D-sub Connector Cable Assembly Terminal No.


Cable 0.3 mm2 x 25 cores O.D. 1.4 10 Seal (Length indication) 015 L Molded cover 44 2-M2.6 x 0.45 SMC 8 Connector DB-25SF-N Manufactured by Japan Aviation Electronics Industry, Ltd. Socket side Terminal no. 113 47.04 Terminal Lead wire Dot number color marking 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Black Brown Red Orange Yellow Pink Blue Purple Gray White White Yellow Orange Yellow Pink Blue Purple Gray Orange Red Brown Pink Gray Black White None None None None None None None White Black Black Red Red Red Black Black White None None Black White White Red Red White None

Ds

Valves are numbered from the D side.

Electrical wiring specifications D-sub connector


As the standard electrical wiring specifications, double wiring (connected to SOL. A and SOL. B) is adopted for the internal wiring of each station for 12 stations or less, regardless of valve and option types. Mixed single and double wiring is available as an option. For details, refer to page 2-3-54.

14 15 16 17 18 19 20 21 22 23 24 25

1 2 3 4 5 6 7 8 9 10 11 12 13

Connector terminal no.

(2.4)

55 1425

Lead wire colors for D-sub connector assembly 015 (AXT100-DS25- 030 )
050

16

Terminal no.
SOL.A

Polarity
(+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) ()

Lead wire color


Black Yellow Brown Pink Red Blue Orange Purple Yellow Gray Pink Orange Blue Red Purple Brown Gray Pink White Gray White Black Yellow White Orange
Note)

Dot marking
None Black None Black None White None None None None None Black None White White White Black Red Black Red Red White Red None Red

1 station 2 stations 3 stations 4 stations 5 stations 6 stations 7 stations 8 stations 9 stations 10 stations 11 stations 12 stations

1 14 2 15 3 16 4 17 5 18 6 19 7 20 8 21 9 22 10 23 11 24 12 25 13

() () () () () () () () () () () () () () () () () () () () () () () () (+)

SOL.B SOL.A SOL.B SOL.A SOL.B SOL.A SOL.B SOL.A SOL.B SOL.A SOL.B SOL.A SOL.B SOL.A SOL.B SOL.A SOL.B SOL.A SOL.B SOL.A SOL.B SOL.A SOL.B COM.

D-sub Connector Cable Assembly (Option)


Cable Assembly part no. length (L) 1.5 m 3m 5m AXT100-DS25-015 AXT100-DS25-030 AXT100-DS25-050 Note Cable 0.3 mm2 x 25 cores

For other commercial connectors, use a 25 pins type with female connector conforming to MIL-C-24308. Cannot be used for transfer wiring.

Electric Characteristics
Item
Characteristics

Connector manufacturers example


Fujitsu, Ltd. Japan Aviation Electronics Industry, Ltd. J.S.T. Mfg. Co., Ltd. Hirose Electric Co., Ltd.

Conductor resistance 65 or less /km, 20C Voltage limit VAC, 1 min. 1000

Insulation resistance 5 or less M/km, 20C


Note) The minimum bending radius for D-sub connector cables is 20 mm.

Positive common specifications

Negative common specifications

Note) When using the negative common specifications, use valves for negative common.

2-3-12

Plug-in Unit

Series

SQ1000

L4
5.25 49.5 47 25 20.5
(Mounting hole dimension)

10.3 M5: External pilot port 47.8 33.2 1.5

L3 L2 L1 P = 11.5

19.2 1.5

Indicator light Manual override

VQC SQ VQ0 VQ4 VQ5

122 (3 position) 113 [Double (Double solenoid), Dual 3 port valve] 108.5 [Single, Double (Latching)] 94 10 47 34 4.6

(108.5)

35 74.5

10

2-M4 clamp screw 9 EXH outlet

Applicable connector: D-sub connector (25P) (Conforming to MIL-C-24308)

Release for switching connector direction

D side
C8: 3(R) port C8: 1(P) port

Stations

U side
9

For top ported

4 R 3

13

28

29.5 13

7.5

43.5 58 P = 11.5 2n-C3, C4, C6, M5 (4(A), 2(B) port) C3: One-touch fitting for 3.2 C4: One-touch fitting for 4 C6: One-touch fitting for 6 M5: M5 thread

Dimensions
L L1 L2 L3 L4 n 1 67 84.5 112.5 123 2 78.5 96 125 135.5 3 90 107.5 137.5 148 4 101.5 119 150 160.5 5 113 130.5 150 160.5 7 6 124.5 136 142 153.5 162.5 175 173 185.5 8 147.5 165 187.5 198 10 9 159 170.5 176.5 188 200 212.5 210.5 223 11 182 199.5 225 235.5

Formula: L1 = 11.5n + 55.5, L2 = 11.5n + 73 12 193.5 211 237.5 248 13 205 222.5 250 260.5 14 216.5 234 262.5 273 15 228 245.5 275 285.5 16 239.5 257 287.5 298 17 251 268.5 300 310.5 18 262.5 280 300 310.5

n: Stations (Maximum 24 stations) 21 20 285.5 297 303 314.5 325 337.5 335.5 348 22 308.5 326 350 360.5 24 23 320 331.5 337.5 349 362.5 375 373 385.5

19 274 291.5 312.5 323

26 37

60

5.5

A B

A B

A B

A B

1.TURN

2.PUSH

1.TURN

2.PUSH

VQZ VQD

2-3-13

Series

SQ1000

Kit (Flat ribbon cable connector)

Simplification and labor savings for wiring work can be achieved by using a flat ribbon cable for the electrical connection. Using connector for flat ribbon cable (26P, 20P) conforming to MIL standard permits the use of connectors put on the market and gives a wide interchangeability. Top or side entry for the connector can be changed freely, allowing later changes according to the mounting space.

Manifold Specifications
Series Port location Side, Top Porting specifications Port size 1(P), 3(R) 4(A), 2(B) C8 Maximum number of stations

SQ1000

12 stations C3, C4, C6, M5 (24 as an option)


ide

Flat Ribbon Cable (26 pins, 20 pins)


Cable assembly
1 AXT100-FC 20 - 2 26 3 Type 26P flat ribbon cable connector assemblies can be ordered with manifolds. Refer to manifold ordering.
Ds ide

Us

23

ta s

tion

Valves are numbered from the D side.

Terminal no. Red

28AWG

Electrical wiring specifications


Flat ribbon cable connector
26 24 22 20 25 23 21 19 17 15 13 11 9 7 5 3 1

18 16 14

(15.6) L

12 10 8 6 4 2

Double wiring (connected to SOL. A and SOL. B) is adopted for the internal wiring of each station, regardless of valve and option types. Mixed single and double wiring is available as an option. For details, refer to page 2-354. Connector terminal no. Triangle mark indicator position

30 (20P) 37.5 (26P)

26

Flat Ribbon Cable Connector Assembly (Option)


20P 26P 1.5 m AXT100-FC20-1 AXT100-FC26-1 3m AXT100-FC20-2 AXT100-FC26-2 5m AXT100-FC20-3 AXT100-FC26-3 For other commercial connectors, use a 26 pins or 20 pins with strain relief conforming to MIL-C-83503. Cannot be used for transfer wiring. Cable length (L) Assembly part no.

25

<26P>
Terminal no. Polarity 1 station 2 stations 3 stations 4 stations 5 stations 6 stations 7 stations 8 stations 9 stations 10 stations 11 stations 12 stations
SOL.A SOL.B SOL.A SOL.B SOL.A SOL.B SOL.A SOL.B 1 () 2 () 3 () 4 () 5 () 6 () 7 () 8 () () () () () () () () () (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+)

<20P>
Terminal no. Polarity 1 station 2 stations 3 stations 4 stations 5 stations 6 stations 7 stations 8 stations 9 stations
SOL.A SOL.B SOL.A SOL.B SOL.A SOL.B SOL.A SOL.B 1 () 2 () 3 () 4 () 5 () 6 () 7 () 8 () () () () () () () () () (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+)

Connector manufacturers example


Hirose Electric Co., Ltd. Sumitomo 3M Limited Fujitsu Limited Japan Aviation Electronics Industry, Ltd. J.S.T. Mfg. Co., Ltd. Oki Electric Cable Co,. Ltd.

SOL.A 9 SOL.B 10 SOL.A 11 SOL.B 12 SOL.A 13 SOL.B 14 SOL.A 15 SOL.B 16

SOL.A 9 SOL.B 10 SOL.A 11 SOL.B 12 SOL.A 13 SOL.B 14 SOL.A 15 SOL.B 16

SOL.A 17 () SOL.B 18 () SOL.A 19 () SOL.B 20 () SOL.A 21 () SOL.B 22 () SOL.A 23 () SOL.B 24 () COM. COM.

SOL.A 17 () SOL.B 18 () COM. COM.

19 (+) () 20 (+) () Positive Negative common common specifications specifications

() 25 (+) () 26 (+) Positive Negative common common specifications specifications

Note) When using the negative common specifications, use valves for negative common.

2-3-14

Plug-in Unit

Series

SQ1000

Applicable connector: Flat ribbon cable connector (26P) (Conforming to MIL-C-83503)

L4
5.25 49.5 47 25 20.5
(Mounting hole dimension)

M5: External pilot port

10.3 47.8 33.2 1.5

L3 L2 L1 P = 11.5

19.2 1.5

Indicator light Manual override

VQC SQ VQ0 VQ4 VQ5

122 (3 position) 113 [Double (Double solenoid), Dual 3 port valve] 108.5 [Single, Double (Latching)] 94 47 10 34 4.6

(108.5)

35 74.5

10

2-M4 clamp screw Triangle mark indicator position Release for switching connector direction

EXH outlet

D side
C8: 3(R) port C8: 1(P) port

Stations

U side
9

For top ported

4 R 3

13

28

29.5 13

7.5

43.5 58 P = 11.5 2n-C3, C4, C6, M5 (4(A), 2(B) port) C3: One-touch fitting for 3.2 C4: One-touch fitting for 4 C6: One-touch fitting for 6 M5: M5 thread

Dimensions
L L1 L2 L3 L4 n 1 67 84.5 112.5 123 2 78.5 96 125 135.5 3 90 107.5 137.5 148 4 101.5 119 150 160.5 5 113 130.5 150 160.5 7 6 124.5 136 142 153.5 162.5 175 173 185.5 8 147.5 165 187.5 198 9 159 176.5 200 210.5 10 170.5 188 212.5 223 11 182 199.5 225 235.5

Formula: L1 = 11.5n + 55.5, L2 = 11.5n + 73 12 193.5 211 237.5 248 13 205 222.5 250 260.5 14 216.5 234 262.5 273 15 228 245.5 275 285.5 16 239.5 257 287.5 298 17 251 268.5 300 310.5 18 262.5 280 300 310.5

n: Stations (Maximum 24 stations) 20 285.5 303 325 335.5 21 297 314.5 337.5 348 22 308.5 326 350 360.5 23 320 337.5 362.5 373 24 331.5 349 375 385.5

19 274 291.5 312.5 323

26 37

60

5.5

A B

A B

A B

A B

1.TURN

2.PUSH

1.TURN

2.PUSH

VQZ VQD

2-3-15

Series

SQ1000

Kit (PC Wiring System compatible flat ribbon cable kit)

PC Wiring System compatible. Using connector for flat ribbon cable (20P) conforming to MIL standard permits the use of connectors put on the market and gives a wide interchangeability. Top or side entry for the connector can be changed freely, allowing later changes according to the mounting space.

Manifold Specifications
Series Porting specifications Port size Port location 1(P), 3(R) 4(A), 2(B) Side, Top C8 Maximum number of stations

SQ1000

8 stations C3, C4, C6, M5 (16 as an option)

ide Us

Ds

ide

12

t s

atio

ns

Valves are numbered from the D side.

Electrical wiring specifications


Double wiring (connected to SOL. A and SOL. B) is adopted for the internal wiring of each station, regardless of valve and option types. Mixed single and double wiring is available as an option. For details, refer to page 2-3-54.

Terminal no.

Polarity
() () () () () () () () () () () () () () () () () () (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) ()

Flat ribbon cable connector


1 station
20 18 16 14 12 10 8 6 4 2 19 17 15 13 11 9 7 5 3 1

SOL.A SOL.B SOL.A

20 18 16 14 12 10 8 6 19 17 15 13 11 9 7 5 4 3

2 stations

SOL.B SOL.A

3 stations

SOL.B SOL.A

4 stations Connector terminal no. 5 stations

SOL.B SOL.A SOL.B SOL.A

Triangle mark indicator position

6 stations

SOL.B SOL.A

7 stations

SOL.B SOL.A

8 stations

SOL.B

COM. COM.

2 1

() (+) Positive Negative common common specifications specifications

Note) When using the negative common specifications, use valves for negative common. For details about the PC Wiring System, refer to catalog CAT.ES02-20 separately.

2-3-16

Plug-in Unit

Series

SQ1000

L4
5.25 49.5 47 25 20.5
(Mounting hole dimension)

M5: External pilot port

10.3 47.8 33.2 1.5

L3 L2 L1 P = 11.5

19.2 1.5

Indicator light Manual override

VQC SQ VQ0 VQ4 VQ5

122 (3 position) 113 [Double (Double solenoid), Dual 3 port valve] 108.5 [Single, Double (Latching)] 94 47 10 4.6 34

(108.5)

35 74.5

10

2-M4 clamp screw

Applicable connector: Flat ribbon cable connector (20P) (Conforming to MIL-C-83503)

Triangle mark indicator position Release for switching connector direction

EXH outlet

D side

Stations

U side
9

C8: 3(R) port C8: 1(P) port For top ported

4 R 3

13

28

29.5 13

7.5

43.5 58

P = 11.5

2n-C3, C4, C6, M5 (4(A), 2(B) port) C3: One-touch fitting for 3.2 C4: One-touch fitting for 4 C6: One-touch fitting for 6 M5: M5 thread

Dimensions
L L1 L2 L3 L4 n 3 2 1 78.5 90 67 84.5 96 107.5 112.5 125 137.5 123 135.5 148

Formula: L1 = 11.5n + 55.5, L2 = 11.5n + 73 4 101.5 119 150 160.5 5 113 130.5 150 160.5 7 6 124.5 136 142 153.5 162.5 175 173 185.5 8 147.5 165 187.5 198 9 159 176.5 200 210.5 10 170.5 188 212.5 223

n: Stations (Maximum 16 stations) 12 193.5 211 237.5 248 13 205 222.5 250 260.5 14 216.5 234 262.5 273 15 228 245.5 275 285.5 16 239.5 257 287.5 298

11 182 199.5 225 235.5

26 37

60

5.5

A B

A B

A B

A B

1.TURN

2.PUSH

1.TURN

2.PUSH

VQZ VQD

2-3-17

Series

SQ1000

Kit (Lead wire cable)

Direct electrical entry type

Manifold Specifications
Series Port location Porting specifications Port size 1(P), 3(R) 4(A), 2(B) C8 C3, C4, C6, M5 Maximum number of stations 12 stations
Us ide

SQ1000

Side, Top

Ds

ide

23

ta s

tion

Valves are numbered from the D side.

Wiring Specifications: Positive COM Specifications


Three lead wires are included per station regardless of valves used. Among the three lead wires, the red wire is for COM.

Wiring Specifications: Negative COM Specifications (Option)


Three lead wires are included per station regardless of valves used. Among the three lead wires, the black wire is for COM.

Lead wire color


SOL.A () COM. (+) SOL.B () Black Red White SOL.A ()

Lead wire color


Black Red White SOL.A (+) COM. (+) SOL.B ()

Lead wire color


Red Black White SOL.A (+) SOL.B (+) COM. () SOL.B (+)

Lead wire color


Red COM. () Black White

Single solenoid

Double solenoid Black: A side solenoid () Red: COM (+)

Single solenoid

Double solenoid Red: A side solenoid (+) Black: COM ()

Station number

Station number

24AWG x 3 core cable O.D. 1.5

White: B side solenoid () (Not used for single solenoid)

24AWG x 3 core cable O.D. 1.5

1
White: B side solenoid (+) (Not used for single solenoid)
Note) When using the negative common specifications, use valves for negative common.

2-3-18

Plug-in Unit

Series

SQ1000

L4
5.25 49.5 47 Electrical entry 32 G1/2 20.5 (Mounting hole dimension) Station number AWG24 Lead wire 122 (3 position) 113 [Double (Double solenoid), Dual 3 port valve] 108.5 [Single, Double (Latching)] 74.5 47 10 4.6 34 7.25 37 22.3 1.5 L3 L2 L1 P = 11.5

19.2 1.5

Indicator light Manual override

VQC SQ VQ0 VQ4 VQ5

(108.5)

35 74.5

10

2-M4 clamp screw

M5: External pilot port

EXH outlet

Lead wire length: L 0, 600 mm L 1, 1500 mm L 2, 3000 mm

C8: 3(R) port C8: 1 (P) port

For top ported

4 R 3

(49.5) 29.5 13

7.5

29.5 44 P = 11.5 2n-C3, C4, C6, M5 (4(A), 2(B) port) C3: One-touch fitting for 3.2 C4: One-touch fitting for 4 C6: One-touch fitting for 6 M5: M5 thread

Dimensions
L L1 L2 L3 L4 n 1 56 70.5 100 110.5

Formula: L1 = 11.5n + 44.5, L2 = 11.5n + 59 n: Stations (Maximum 12 stations) 4 90.5 105 125 135.5 5 102 116.5 137.5 148 7 6 113.5 125 128 139.5 150 162.5 160.5 173 8 136.5 151 175 185.5 11 10 9 148 159.5 171 162.5 174 185.5 187.5 200 212.5 198 210.5 223 12 182.5 197 225 235.5

3 2 67.5 79 93.5 82 112.5 125 123 135.5

26 37

60

D side

Stations

U side

13

28

5.5

A B

A B

A B

A B

1.TURN

2.PUSH

1.TURN

2.PUSH

VQZ VQD

SMC

2-3-19

Series

SQ1000

Kit (Serial transmission unit)

The serial transmission system reduces wiring work, while minimizing wiring and saving space. The maximum number of stations is 8. (16 as an option). Only for type J2 and R2, the maximum stations are 4 (8 as an option).

Manifold Specifications
Series Port location Porting specifications Port size 1(P), 3(R) C8 4(A), 2(B) C3, C4, C6, M5 Maximum number of stations 8 stations

SQ1000

Side, Top

12

st

atio

ns
Us ide

Stations are counted from station 1 on the D side. Double wiring (connected to SOL. A and SOL. B) is adopted for the internal wiring of each station, regardless of valve and option types. M3 screw
Item External power supply Current consumption (Inside unit) Specifications 24 VDC, +10%, 5% 0.1 A or less

24

Ds

ide

Corresponding SI unit output numbers and solenoid coils <Wiring example 1>
SI unit output no. 0 1 2 3 4 5 6 7 8 9

None

None

SI unit

Double

Double

Single

Single

Single

Stations

Double wiring (Standard)

<Wiring example 2>


Mixed wiring is available as an option. Specify the wiring specification by means of the manifold specification sheet. Refer to page 2-3-54 for details.
SI unit output no. 0 1 2 3 4 5 6 7

SI unit

Double

Double

Single

Single

Double

Stations

Mixed single and double wiring (Option)

2-3-20

Plug-in Unit

Series

SQ1000

Type SDF NKE Corporation Uni-wire System

Type SDH NKE Corporation Uni-wire H System

Type SDJ1, SDJ2 SUNX Corporation S-LINK System

VQC
Name of terminal block, LED
ADDRESS
ON

ADDRESS
ON

DIP SW. POWER SEND


ON

SQ VQ0

POWER SEND

POWER SEND

24V 0V

24V

0V

24V 0V

24V

0V

0V

24V

0V

24V

VQ4 VQ5

LED

Description Light ON with power input (Light ON when normal, flickers when voltage is low) Transmission indicator Normal: Blinks, Abnormal: Light OFF or ON

LED

Description Light ON with power input (Light ON when normal, flickers when voltage is low) Transmission indicator Normal: Blinks, Abnormal: Light OFF or ON

LED

Description Light ON with power input Transmission indicator Normal: Blinks, Abnormal: Blinks slowly

VQZ VQD

POWER SEND

POWER SEND

POWER SEND

DG

DG

a) Type T branching multi-drop wiring (S-LINK System) Power { 24 V supply 0 V

b) Crossover wiring (Sensor link system)

Power { 24 V supply 0 V

Power { 24 V supply 0 V

24V 0V D G D G 24V 0V

Power { 24 V supply 0 V Transmission line

24V 0V D G D G 24V 0V

G D 0V 24V G D 0V 24V

G D 0V 24V G D 0V 24V

Black White

Brown Blue Transmission line

Cable wiring

Transmission line

Main Crimp connector SL-J1A transmission line

The above is the example of using dedicated S-LINK flat ribbon cable SL-RCM00.

Power { 24 V supply 0 V

Power { 24 V supply 0 V

24V 0V D G D G 24V 0V

Power { 24 V supply 0 V

Power { 24 V supply 0 V

24V 0V D G D G 24V 0V

DG

DG

Uni-wire System Send unit: SD-120

Uni-wire H System Send unit: SD-H2

S-LINK System S-LINK controller: SL-CU1

Note

No. of output points, 16 points

No. of output points, 16 points

No. of output points, 16 points (Type SDJ1) No. of output points, 8 points (Type SDJ2)

2-3-21

Series

SQ1000

Kit (Serial transmission unit)

Type SDQ OMRON Corporation DeviceNet, CompoBus/D

Type SDR1, SDR2 OMRON Corporation CompoBus/S System

Type SDV Mitsubishi Electric Corporation CC-LINK System

Name of terminal block, LED

SETTINGS PWR MOD/NET


ON

ADDRESS NO. PWR COM ERR


ON

PWR

L RUN

B RATE STATION NO.

L ERR. SD 24 V OV V- CAM FG CAM Vt

RD

BS+ BDH BDL BS-

FG

24 V 0 V

24 V 0 V +24V

24G

DA

DB

DG

FG

LED

Description
Light OFF: When the unit is not online or circuit power is OFF

LED

Description

LED

Description
Light ON with transmission power input, light Off without it

POWER Green light ON with circuit power input

POWER

Green light ON continuously: When the unit is online and in operation MOD/ Red light blinks: When a reversible NET abnormal transmission occurs Red light ON continuously: When irreversible abnormal transmission occurs or the same line is unable to go online

Light ON with transmission power input, light Off without it Light ON with normal transmission, light OFF with abnormal or standby COMM transmission Light ON with abnormal transmission, ERR. light Off with normal or standby transmission

POWER SD RD L ERR.

L RUN Light ON when receiving normal data Light ON when sending data Light ON when receiving data
Light ON with transmission error/setting error, light blinks with changes in the station no. or transmission speed setting

24 V 0 V V- CANL FG CANH V+

24 V 0 V V- CANL FG CANH V+

BS+ BDH BDL BS- 24 V 0 V

BS+ BDH BDL BS- 24 V 0 V Terminal resistor Master unit


DA DB DG SLD FG

SI unit
DA DB DG FG

SI unit
DA DB DG FG

Cable wiring

Terminal resistor

VCANL FG CANH V+

BDH BDL

Connector With terminal resistor

Master

Type 3 ground

Type 3 ground Type 3 ground Twisted pair line with shielding

Branch crimped connectors

DeviceNet OMRON Corporation CompoBus/D System Master unit: C200HW-DRM21

CompoBus/S System Master unit: C200HW-SRM21 Master unit: CQM1-SRM21

CC-LINK System Master unit: AJ61BT11 Master unit: A1SJ61BT11 Master unit: AJ61QBT11

Note

No. of output points, 16 points No. of output points, 16 points (Type SDR1) No. of output points, 8 points (Type SDR2)

Master unit: A1SJ61QBT11

No. of output points, 16 points

2-3-22

Plug-in Unit

Series

SQ1000

L4
5.25 22.2 49.5 47 M5: External pilot port 59.5 44.7 L3 L2 L1 P = 11.5 19.2 1.5 Indicator light Manual override

VQC SQ VQ0 VQ4

122 (3 position) 113 [Double (Double solenoid), Dual 3 port valve] 108.5 [Single, Double (Latching)] 101 68 47 34 10 4.6

SERIAL UNIT

EX140-SCS1

No.

BS+ BDH BDL


PWR. COMM ERR.

(108.5)

VQ5
35 74.5 2-M4 clamp screw

10

1.5

EXH outlet

D side
C8: 3(R) port C8: 1(P) port

Stations

U side
9

For top ported

4 R 3

13

28

(49.5) 29.5 13

7.5

67 81.5 P = 11.5 2n-C3, C4, C6, M5 (4(A), 2(B) port) C3: One-touch fitting for 3.2 C4: One-touch fitting for 4 C6: One-touch fitting for 6 M5: M5 thread

Dimensions
L L1 L2 L3 L4 n

Formula: L1 = 11.5n + 67, L2 = 11.5n + 96.5 5 124.5 154 175 185.5 6 136 165.5 187.5 198 8 7 147.5 159 177 188.5 200 212.5 210.5 223 9 170.5 200 225 235.5 10 182 211.5 237.5 248

n: Stations (Maximum 16 stations) 12 205 234.5 262.5 273 13 216.5 246 275 285.5 14 228 257.5 287.5 298 15 239.5 269 300 310.5 16 251 280.5 300 310.5

4 3 2 1 78.5 90 101.5 113 108 119.5 131 142.5 137.5 150 162.5 162.5 148 160.5 173 173

11 193.5 223 250 260.5

26 37

2-3-23

60

5.5

A B

A B

A B

A B

1.TURN

2.PUSH

1. TURN

2. PUSH

A
ADDRESS No.

BSFG 24V 0V

VQZ VQD

Series SQ2000

Plug-in Manifold
How to Order Manifold

SS5Q23
Stations
01 16
Note)

08 FD2

D
Option
Nil 02 to 24
(1)

None DIN rail length specified Back pressure check valve


(2)

1 station 16 stations

Note) The maximum number of stations depends on the type of electrical entries.

Electrical entry
Kit type Lead wire connector location U side

Manifold mounting
D E
DIN rail mounting style Direct mounting style

B K N R S

Special wiring specifications (Except double wiring) With name plate (Side ported only) External pilot specifications Built-in silencer, direct exhaust

Note 1) Specify DIN rail length with D at the end. (Enter the number of stations inside .) Example: -D08 Note 2) Standard wiring specifications are for double wiring. Indicate wiring specifications for single wiring or mixed single and double wiring, or when exceeding the standard maximum number of stations. (Except L kit.) Note 3) For specifying two or more options, enter them alphabetically. Example: -BKN
(2) Max. number of stations for special Max. number wiring specifications of solenoids

Cable specifications D-sub connector (25P) kit, without cable

Stations

F kit
D side
D-sub Connector kit

P kit

Flat ribbon cable connector kit

( 26P ) 20P

FD0 FD1 FD2 FD3 PD0 PD1 PD2 PD3 PDC

D side

D-sub connector (25P) kit, with 1.5 m cable D-sub connector (25P) kit, with 3.0 m cable D-sub connector (25P) kit, with 5.0 m cable Flat ribbon cable (26P) kit, without cable Flat ribbon cable (26P) kit, with 1.5 m cable Flat ribbon cable (26P) kit, with 3.0 m cable Flat ribbon cable (26P) kit, with 5.0 m cable Flat ribbon cable (20P) kit, without cable

1 to 12 stations

16 stations

24

(1)

D side

1 to 12 stations

16 stations

24

1 to 9 stations

18

J kit
JD0
Flat ribbon cable (20P) (PC Wiring System compatible)

D side

Flat ribbon cable (20P) PC Wiring System compatible

1 to 8 stations

16 stations

16

T kit
TD0
Terminal block box kit

D side

Terminal block box kit

1 to 10 stations

16 stations

16

L kit

Lead wire kit

S kit

Serial transmission kit

LD0 LU0 LD1 LU1 LD2 LU2 SDF SDH SDJ1 SDJ2 SDQ SDR1 SDR2 SDV

D side U side D side U side D side U side

Lead wire kit with 0.6 m cable Lead wire kit, with 1.5 m cable Lead wire kit, with 3.0 m cable NKE Corp.: Uni-wire System NKE Corp.: Uni-wire H System SUNX Corp.: S-LINK System (16 output points) SUNX Corp.: S-LINK System (8 output points) 1 to 4 stations 1 to 8 stations 1 to 4 stations 1 to 8 stations 8 stations 16 stations 8 stations 16 stations 8 16 8 16 1 to 8 stations 16 stations 16

1 to 12 stations

D side

DeviceNet, CompoBus/D (OMRON Corp.) OMRON Corp.: CompoBus/S System (16 output points) OMRON Corp.: CompoBus/S System (8 output points) Mitsubishi Electric Corp.: CC-LINK System

Note 1) Separately order the 20P type cable assembly for the P kit. Note 2) The maximum number of stations should not be more than the maximum number of solenoids. (The number of solenoids are counted as: 1 for single solenoids and 2 for type 3P and 4P double solenoids.)

2-3-24

Plug-in Unit

Series

SQ2000

How to Order Valves

SQ2 1 3 0
Type of actuation
2 position single
(A) (B) 42

C6
With/Without manifold block
Nil Without manifold block M With manifold block MB With manifold block, built-in back pressure check valve

513 (R1)(P)(R2)

2 position double (Latching)


(A) (B) 42 (A) (B) 42

VQC SQ VQ0
Lead wire is not included. Lead wire is not included. When ordering with manifolds When only valves are required.

513 (R1) (P)(R2)

513 (R1) (P)(R2)

Metal seal

Rubber seal

2 position double (Double solenoid) (1)


(A) (B) 42 (A) (B) 42

VQ4 VQ5 VQZ VQD

513 (R1) (P)(R2)

513 (R1) (P)(R2)

Metal seal

Rubber seal

For adding stations

3 position closed center

(A) (B) 42

51 3 (R1)(P)(R2)

3 position exhaust center

(A)(B) 42

Port plug mounting port


Nil None Port 4(A) Port 2(B)

513 (R1)(P)(R2)

3 position pressure center

(A) (B) 42

A B

513 (R1) (P)(R2)

4 position dual 3 port valve


(2)
(A) 4 (B) 2

Cylinder port
C4 C6 C8 L4 L6 L8
One-touch fitting for 4 One-touch fitting for 6 One-touch fitting for 8 One-touch fitting for 4 One-touch fitting for 6 One-touch fitting for 8
Note) Can be changed to side ported configuration.
Note)

A
5 (R1) 1 (P) 3 (R2)

Side ported

N.C.
(2)
(A) 4

N.C.
(B) 2

4 position dual 3 port valve

B
5 (R1) 1 (P) 3 (R2)

Top ported

N.O.
(2)
(A) 4

N.O.
(B) 2

4 position dual 3 port valve

C
5 (R1) 1 (P) 3 (R2)

Manual override
Nil Non-locking push type (Tool required)

N.C.

N.O.

B Note)
Locking type (Tool required)

D Note)
Slide locking type (Manual type)
Only side ported type applicable

Note 1) For double solenoid specification, the function symbol below is D. Note 2) Only rubber seal types are applicable.

Seal
0 1
Metal seal Rubber seal

Function
Nil Standard type (1.0 W DC) 2 position double (Double solenoid specifications) Negative common Low wattage type (0.5 W DC) External pilot specifications

Note) Except double (latching) type.

D N Y (1) R (2)

Coil voltage
5 6
24 VDC 12 VDC
Note) Light/Surge voltage suppressor is builtin.

Note 1) Except double (latching) type. Note 2) Except dual 3 port valves. Note 3) When two or more symbols are specified, indicate them alphabetically.

2-3-25

Series

SQ2000
P. 2-3-49 Individual SUP/EXH spacer P. 2-3-50 Name plate (-N) SSQ2000-N3-n SSQ2000-PR1-3-C8 L8 P. 2-3-52 External pilot P. 2-3-53

Manifold Option
Blanking plate

SSQ2000-10A-3

specifications (-R)
External pilot port

SUP/EXH block

P. 2-3-49 SUP block plate

P. 2-3-51 Blanking plug

P. 2-3-52 Dual flow fitting

P. 2-3-53

SSQ2000-PR-3-C10 (-S)

SSQ1000-B-R
P

KQ2P-04/06/08/10

SSQ2000-52A- C10 N11

D side

U side

Individual SUP spacer P. 2-3-49 EXH block plate

P. 2-3-51 Port plug

P. 2-3-52 Silencer

P. 2-3-53

SSQ2000-P-3-C8 L8

SSQ2000-B-R
P

VVQZ2000-CP

(For EXH port)

D side

C SM

AN

20

U side

Individual EXH spacer P. 2-3-50 Back pressure check valve (-B) SSQ2000-R-3-C8
L8

P. 2-3-51 Built-in silencer (-S) P. 2-3-52 Special wiring

P. 2-3-54
Terminal no. SOL.A SOL.A SOL.A SOL.A SOL.A 1 ()

SSQ2000-BP

specifications (-K)
D-sub connector 1 station 2 stations 3 stations 4 stations 5 stations 6 stations 7 stations 8 stations

14 () 2 ()

1 14 15 16 17 18 19 20 21 22 23 24 25 2 3 4 5 6 7 8 9 10 11 12 13

15 () 3 ()

SOL.B SOL.A SOL.B SOL.A SOL.B SOL.A SOL.B

16 () 4 ()

17 () 5 ()

18 () 6 ()

19 ()

COM.

13 (+)

Connector terminal no.

Although the standard products come with double wiring, mixed single and double wiring is available upon request.

2-3-26

Plug-in Unit How to Order Manifold Assembly (Example)


Example: D-sub connector kit, with cable (3 m)
2 position single (24 VDC) SQ2130-5-C8 (3 sets)

Series

SQ2000

2 position double (Double solenoid) (24 VDC) 3 position closed center (24 VDC) SQ2330-5-C8 (1 set) SQ2230D-5-C8 (3 sets) Blanking plate 8 SSQ2000-10A-3 (1 set) 7 6 5 e sid 4 U 3
2 1 S tat s ion
-3 0A -1 8 00 -C 20 Q -5 8 30 SS -C -5 23 D Q 8 S 30 -C -5 22 D Q 8 S 30 -C -5 22 D Q 8 S 30 -C 22 -5 Q 8 S 30 -C 21 -5 Q 8 S 30 -C 21 -5 Q 30 S 21 Q S

VQC SQ VQ0 VQ4 VQ5 VQZ

D-sub connector cable AXT100-DS25-030


e

3m

sid

Cylinder port fitting C8: One-touch fittings for 8 Manifold base (8 stations) SS5Q23-08FD2-D

VQD

F kit (D-sub connector kit)

SS5Q23-08FD2-D 1 set (F kit 8 station manifold base) SQ2130-5-C8 3 sets (2 position single) SQ2230D-5-C8 3 sets (2 position double [Double solenoid]) SQ2330-5-C8 1 set (3 position closed center) SSQ2000-10A-3 1 set (Blanking plate)
The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc. Add the valve and option part numbers in order starting from the first station on the D side. When entry of part numbers becomes complicated, indicate on the manifold specification sheet.

2-3-27

Series

SQ2000
(2)

Valve Specifications
Model
Series Number of solenoids Flow characteristics Model Metal seal Rubber seal 1 4/2 (P C [dm3/(sbar)] b A/B) Cv 0.51 0.51 0.51 0.51 0.51 0.51 0.46 0.46 0.46 0.46 0.51 0.56 0.40 4/2 5/3 (A/B C [dm3/(sbar)] b 2.4 3.1 2.4 3.1 2.4 3.1 2.1 1.8 2.4 3.1 2.1 1.8 1.5 0.14 0.18 0.14 0.18 0.14 0.18 0.15 0.29 0.14 0.14 0.18 0.30 0.17 R1/R2) Cv 0.57 0.71 0.57 0.71 0.57 0.71 0.47 0.47 0.55 0.65 0.47 0.47 0.40 Response time (ms) Standard: 1W 20 or less 24 or less 26 or less 31 or less 15 or less 20 or less 34 or less 34 or less 34 or less 34 or less 34 or less 34 or less 34 or less Low wattage 26 or less 31 or less 20 or less 26 or less 44 or less 44 or less 44 or less 44 or less 44 or less 44 or less 44 or less Weight (g) 145 140 145 140 160 155 180 175 180 175 180 175 155

Single 2 position

SQ2130 SQ2131 SQ2230 SQ2231 SQ2230D SQ2231D SQ2330 SQ2331 SQ2430 SQ2431 SQ2530 SQ2531 SQ2 B 31 C
A

2.2 2.3 2.2 2.3 2.2 2.3 1.9 1.9 1.9 1.9 2.3 2.5 1.5

0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17

Metal seal Double (Latching) Rubber seal Double Metal seal (Double solenoid) Rubber seal Closed center Exhaust center Pressure center Metal seal Rubber seal Metal seal Rubber seal Metal seal Rubber seal Rubber seal

SQ2000

4 position

3 position

Dual 3 port valve

Note 1) Values for the top ported cylinder port size of C8. The side ported type will be about 10% less. Note 2) Based on JIS B 8375-1981. (Values with a supply pressure of 0.5 MPa and light/surge voltage suppressor. Values fluctuate depending on the pressure and air quality.)

Specifications
Valve construction Fluid Maximum operating pressure Valve specifications Min. operating pressure Single Double (Latching) Double (Double solenoid) 3 position 4 position 0.1 MPa 0.18 MPa 0.1 MPa 0.1 MPa 10 to 50C
(1)

Metal seal Air/Inert gas 0.7 MPa

Rubber seal

0.15 MPa 0.18 MPa 0.1 MPa 0.2 MPa 0.15 MPa

JIS Symbol
2 position single
(A) (B) 42

Ambient fluid temperature Lubrication Pilot valve manual override Vibration/Impact resistance
(2)

Not required Push type (Tool required)/Slide locking type (Tool required) 30/150 m/s2 Dust tight 12 VDC, 24 VDC 10% of rated voltage Equivalent to class B 24 VDC 12 VDC 1 W DC (42 mA), 0.5 W DC (21 mA) (3) 1 W DC (83 mA), 0.5 W DC (42 mA) (3)

51 3 (R1)(P)(R2)

Protection structure Solenoid specifications Coil rated voltage Allowable voltage fluctuation Coil insulation type Power consumption (Current)

2 position double (Latching)


(A) (B) 42 (A) (B) 42

513 (R1)(P)(R2)

513 (R1)(P)(R2)

Metal seal
(A) (B) 42

Rubber seal
(A) (B) 42

2 position double (Double solenoid)

5 13 (R1) (P)(R2)

5 13 (R1) (P)(R2)

Note 1) Use dry air to prevent condensation when operating at low temperatures. Note 2) Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 2000 Hz. Test was performed at both energized and de-energized states in the axial direction and at the right angles to the main valve and armature. (Values at the initial period) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition. (Values at the initial period) Note 3) Values for the low wattage (0.5 W) specifications.

Metal seal
(A) (B) 42

Rubber seal

3 position closed center

3 position pressure center


(A) (B) 42

4 position dual 3 port valve (B)


4 2

5 513 (R1)(P)(R2) 51 3 (R1)(P)(R2)

3 1

N.O.

N.O.

3 position exhaust center


(A) (B) 4 2

4 position dual 3 port valve (A)


4 2

4 position dual 3 port valve (C)


4 2

5 51 3 (R1)(P)(R2)

3 1

3 1

N.C.

N.C.

N.C.

N.O.

2-3-28

Plug-in Unit Manifold Specifications


Porting specifications Base model 1(P), 3(R) Series SQ2000 C10 (For 10) Option Built-in silencer, direct exhaust Side C4 (For 4) C6 (For 6) C8 (For 8) SQ2 SQ2
(2)

Series

SQ2000
(3) (4) (4)

Port size (1) 4(A), 2(B) Port location Port size

Applicable solenoid valve

Type of connection

Applicable stations

5 station weight (g) 580 580 580 1,165 620 650

1 station weight (g) 35 35

F kit: D-sub connector P kit: Flat ribbon cable 30 31 J kit: Flat ribbon cable PC Wiring System compatible T kit: Terminal block L kit: Lead wire S kit: Serial transmission 20P

1 to 12 stations 26P 1 to 12 stations 1 to 9 stations 1 to 8 stations 1 to 10 stations 1 to 12 stations 1 to 8 stations

VQC
35 620 50 35

SS5Q23-

Top

L4 (For 4) L6 (For 6) L8 (For 8)

SQ VQ0 VQ4 VQ5 VQZ VQD

Note 1) One-touch fittings in inch sizes are also available. For details, refer to page 2-3-56. Note 2) Can be changed to side ported configuration. Note 3) An optional specification for special wiring is available to increase the maximum number of stations. Refer to page 2-3-54 for details. Note 4) Except valves. For valve weight, refer to page 2-3-28.

4(A), 2(B) port 3(R) port 1(P) port 25P 26P/20P (P kit) 20P (J kit)

F kit

P kit J kit

T kit

L kit

S kit

2-3-29

Series

SQ2000

Kit (D-sub connector kit)

Simplification and labor savings for wiring work can be achieved by using a D-sub connector for the electrical connection. Using connector for flat ribbon cable (25P) conforming to MIL standard permits the use of connectors put on the market and gives a wide interchangeability. Top or side entry for the connector can be changed freely, allowing later changes according to the mounting space.

Manifold Specifications
Series Port location Side, Top Porting specifications Port size 1(P), 3(R) 4(A), 2(B) C10 C4, C6, C8 Maximum number of stations 12 stations (16 as an option)

SQ2000

D-sub Connector (25 pin)


Cable assembly
015 AXT100-DS25- 030 050 D-sub connector cable assemblies can be ordered with manifolds. Refer to manifold ordering.
id Ds e

Us

ide

3 12

t s

atio

ns

D-sub Connector Cable Assembly Terminal No.


Cable 0.3 mm2 x 25 cores O.D. 1.4 10 Seal (length indication) 015 L Molded cover 44 2-M2.6 x 0.45 SMC 8 connector DB-25SF-N Terminal Lead wire Dot number color marking 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Black Brown Red Orange Yellow Pink Blue Purple Gray White White Yellow Orange Yellow Pink Blue Purple Gray Orange Red Brown Pink Gray Black White None None None None None None None White Black Black Red Red Red Black Black White None None Black White White Red Red White None

Valves are numbered from the D side.

Electrical wiring specifications D-sub connector


As the standard electrical wiring specifications, double wiring (connected to SOL. A and SOL. B) is adopted for the internal wiring of each station for 12 stations or less, regardless of valve and option types. Mixed single and double wiring is available as an option. For details, refer to page 2-3-54.

14 15 16 17 18 19 20 21 22 23 24 25

1 2 3 4 5 6 7 8 9 10 11 12 13

(2.4)

55 1425

manufactured by Japan Aviation Electronics Industry, Ltd.

Connector terminal no.

Socket side Terminal no.

Lead wire colors for D-sub connector assembly 015 (AXT100-DS25- 030 )
050
SOL.A

Terminal no.
1 14 2 15 3 16 4 17 5 18 6 19 7 20 8 21 9 22 10 23 11 24 12 25 13

16

Polarity
() () () () () () () () () () () () () () () () () () () () () () () () (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) ()

Lead wire Dot color marking


Black Yellow Brown Pink Red Blue Orange Purple Yellow Gray Pink Orange Blue Red Purple Brown Gray Pink White Gray White Black Yellow White Orange
Note)

113 47.04

1 station 2 stations 3 stations 4 stations 5 stations 6 stations 7 stations 8 stations

None Black None Black None White None None None None None Black None White White White Black Red Black Red Red White Red None Red

SOL.B SOL.A SOL.B SOL.A SOL.B SOL.A SOL.B SOL.A SOL.B SOL.A SOL.B SOL.A SOL.B SOL.A SOL.B SOL.A SOL.B SOL.A SOL.B SOL.A SOL.B SOL.A SOL.B COM.

D-sub Connector Cable Assembly (Option)


Cable Assembly part no. length (L) 1.5 m 3m 5m AXT100-DS25-015 AXT100-DS25-030 AXT100-DS25-050 Note Cable 0.3 mm2 x 25 cores

For other commercial connectors, use a 25 pins type with female connector conforming to MILC-24308. Cannot be used for transfer wiring.

Electric Characteristics
Item
Characteristics

Connector manufacturers example


Fujitsu, Ltd. Japan Aviation Electronics Industry, Ltd. J.S.T. Mfg. Co., Ltd. Hirose Electric Co., Ltd.

9 stations 10 stations 11 stations 12 stations

Conductor resistance 65 or less /km, 20C Voltage limit VAC, 1 min. 1000

Insulation resistance 5 or less M/km, 20C


Note) The minimum bending radius for D-sub connector cables is 20 mm.

Positive common Negative common specifications specifications

Note) When using the negative common specifications, use valves for negative common.

2-3-30

Plug-in Unit

Series

SQ2000

L4
5.25 58 25 18
(Mounting hole dimension)

M5: External pilot port Release for switching connector direction

15.5

47.8 29 1

L3 L2 L1 P = 17.5

Indicator light 28.8 Manual override

VQC SQ VQ0 VQ4

147 (3 position) 131.5 [Single, Double, Dual 3 port valve] 122.3 70 56 35 10.4 5.5 5.5

2-M4 clamp screw

VQ5 VQZ VQD

(131.5)

12

12

EXH outlet Applicable connector: D-sub connector (25P) (Conforming to MIL-C-24308)

D side
C10: 3(R) port C10: 1(P) port

Stations

U side
10

For top ported

18.5 37.6 53.6


B

(58) 39.5 21

2 P 1

44.5 63.3

7.5

P = 17.5

2n-C4, C6, C8 (4(A), 2(B) port) C4: One-touch fitting for 4 C6: One-touch fitting for 6 C8: One-touch fitting for 8

Dimensions
L L1 L2 L3 L4 n 1 69.5 92 112.5 123 2 87 109.5 137.5 148 3 104.5 127 150 160.5

Formula: L1 = 17.5n + 52, L2 = 17.5n + 74.5 4 122 144.5 175 185.5 5 139.5 162 187.5 198 6 157 179.5 200 210.5 8 7 174.5 192 197 214.5 225 237.5 235.5 248 10 9 209.5 227 232 249.5 262.5 275 273 285.5

n: Stations (Maximum 16 stations) 12 262 284.5 312.5 323 13 279.5 302 325 335.5 14 297 319.5 350 360.5 15 314.5 337 362.5 373 16 332 354.5 375 385.5

11 244.5 267 287.5 298

2-3-31

25.5 41.5

62

A 4

B 2

1.TURN

2.PUSH

1.TURN

2.PUSH

SMC

Series

SQ2000

Kit (Flat ribbon cable connector)


Manifold Specifications
Series Port location Porting specifications Port size 1(P), 3(R) 4(A), 2(B) C10 C4, C6, C8
Us ide

Simplification and labor savings for wiring work can be achieved by using a flat ribbon cable for the electrical connection. Using connector for flat ribbon cable (26P, 20P) conforming to MIL standard permits the use of connectors put on the market and gives a wide interchangeability. Top or side entry for the connector can be changed freely, allowing later changes according to the mounting space.

Maximum number of stations 12 stations (16 as an option)

SQ2000

Side, Top

Flat Ribbon Cable (26 pins, 20 pins)


Cable assembly
1 AXT100-FC 20 - 2 26 3
Ds ide

23 1

st

atio

ns

Type 26P flat ribbon cable connector assemblies can be ordered with manifolds . Refer to manifold ordering.

Valves are numbered from the D side.

Terminal no. Red

28AWG

Electrical wiring specifications


Flat ribbon cable connector
26 24 22 20 18 16 14 12 10 8 6 4 2 25 23 21 19 17 15 13 11 9 7 5 3 1

Double wiring (connected to SOL. A and SOL. B) is adopted for the internal wiring of each station, regardless of valve and option types. Mixed single and double wiring is available as an option. For details, refer to page 2-3-54.

30 (20P) 37.5 (26P)

26

25

(15.6) L

Connector terminal no. Triangle mark indicator position

Flat Ribbon Cable Connector Assembly (Option)


Assembly part no. 20P 26P 1.5 m AXT100-FC20-1 AXT100-FC26-1 3m AXT100-FC20-2 AXT100-FC26-2 5m AXT100-FC20-3 AXT100-FC26-3 For other commercial connectors, use a 26 pins or 20 pins with strain relief conforming to MIL-C-83503. Cannot be used for transfer wiring. Cable length (L)

<26P>
Terminal no. Polarity 1 station 2 stations 3 stations 4 stations 5 stations 6 stations 7 stations 8 stations 9 stations 10 stations 11 stations 12 stations
SOL.A SOL.B SOL.A SOL.B SOL.A SOL.B SOL.A SOL.B SOL.A SOL.B 1 2 3 4 5 6 7 8 9 10 () () () () () () () () () () () () () () () () () () () () () () () () (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) 7 stations (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) ()

<20P>
Terminal no. Polarity 1 station 2 stations 3 stations 4 stations 5 stations 6 stations
SOL.A SOL.B SOL.A SOL.B SOL.A SOL.B SOL.A SOL.B 1 () 2 () 3 () 4 () 5 () 6 () 7 () 8 () () () () () () () () () (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) ()

Connector manufacturers example


Hirose Electric Co., Ltd. Sumitomo 3M Limited Fujitsu Limited Japan Aviation Electronics Industry, Ltd. J.S.T. Mfg. Co., Ltd. Oki Electric Cable Co,. Ltd.

SOL.A 11 SOL.B 12 SOL.A 13 SOL.B 14 SOL.A 15 SOL.B 16 SOL.A 17 SOL.B 18 SOL.A 19 SOL.B 20 SOL.A 21 SOL.B 22 SOL.A 23 SOL.B 24 COM. COM. 25

8 stations 9 stations

SOL.A 9 SOL.B 10 SOL.A 11 SOL.B 12 SOL.A 13 SOL.B 14 SOL.A 15 SOL.B 16

SOL.A 17 () SOL.B 18 () COM. COM. 19 (+) 20 (+)

() Positive Negative common common specifications specifications

() (+) 26 Positive Negative common common specifications specifications

Note) When using the negative common specifications, use valves for negative common.

2-3-32

Plug-in Unit

Series

SQ2000

L4
5.25 58 25 18
(Mounting hole dimension)

M5: External pilot port Release for switching connector direction

15.5

47.8 29 1

L3 L2 L1 P = 17.5

Indicator light 28.8 Manual override

VQC SQ VQ0 VQ4

147 (3 position) 131.5 [Single, Double, Dual 3 port valve] 122.3 70 56 10.4 35 5.5 5.5

2-M4 clamp screw

VQ5 VQZ VQD

(131.5)

Triangle mark indicator position Applicable connector: Flat ribbon cable connector (26P) (Conforming to MIL-C-83503)

12

12

EXH outlet

D side
C10: 3(R) port C10: 1(P) port

Stations

U side
10

For top ported

A R 3

(58)

2 P 1

7.5

44.5 63.3 P = 17.5 2n-C4, C6, C8 ( 4(A), 2(B) port) C4: One-touch fitting for 4 C6: One-touch fitting for 6 C8: One-touch fitting for 8

Dimensions
L L1 L2 L3 L4 n 1 69.5 92 112.5 123 2 87 109.5 137.5 148 3 104.5 127 150 160.5

Formula: L1 = 17.5n + 52, L2 = 17.5n + 74.5 4 122 144.5 175 185.5 6 5 139.5 157 162 179.5 187.5 200 198 210.5 7 174.5 197 225 235.5 8 192 214.5 237.5 248 10 9 209.5 227 232 249.5 262.5 275 273 285.5

n: Stations (Maximum 16 stations) 13 279.5 302 325 335.5 15 14 297 314.5 319.5 337 350 362.5 360.5 373 16 332 354.5 375 385.5

12 11 244.5 262 267 284.5 287.5 312.5 298 323

2-3-33

25.5 41.5

39.5 21

62

18.5 37.6 53.6

A 4

B 2

1.TURN

2.PUSH

1.TURN

2.PUSH

SMC

Series

SQ2000

Kit (PC Wiring System compatible flat ribbon cable kit)

PC Wiring System compatible. Using connector for flat ribbon cable (20P) conforming to MIL standard permits the use of connectors put on the market and gives a wide interchangeability. Top or side entry for the connector can be changed freely, allowing later changes according to the mounting space.
ide

Manifold Specifications
Series Port location Porting specifications Port size 1(P), 3(R) 4(A), 2(B) C10 C4, C6, C8 Maximum number of stations 8 stations (16 as an option)

SQ2000

Side, Top

Us

e sid

23 1

st

atio

ns

Valves are numbered from the D side.

Electrical wiring specifications


Double wiring (connected to SOL. A and SOL. B) is adopted for the internal wiring of each station, regardless of valve and option types. Mixed single and double wiring is available as an option. For details, refer to page 2-3-54.

Terminal no. Polarity

Flat ribbon cable connector


1 station
20 18 16 14 12 10 8 6 4 2 19 17 15 13 11 9 7 5 3 1

SOL.A SOL.B SOL.A

20 18 16 14 12 10 8 6 19 17 15 13 11 9 7 5 4 3

() () () () () () () () () () () () () () () () () () (+) (+)

(+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) () ()

2 stations

SOL.B SOL.A

3 stations

SOL.B SOL.A

4 stations Connector terminal no. 5 stations

SOL.B SOL.A SOL.B SOL.A

Triangle mark indicator position

6 stations

SOL.B SOL.A

7 stations

SOL.B SOL.A

8 stations

SOL.B

COM. COM.

2 1

Positive Negative Note) common common specifications specifications

Note) When using the negative common specifications, use valves for negative common. For details about the PC Wiring System, refer to catalog CAT.ES02-20 separately.

2-3-34

Plug-in Unit

Series

SQ2000

L4
5.25 58 25 18
(Mounting hole dimension)
15.5

M5: External pilot port Release for switching connector direction

47.8 29 1

L3 L2 L1 P = 17.5

Indicator light 28.8 Manual override

VQC SQ VQ0 VQ4

147 (3 position) 131.5 [Single, Double, Dual 3 port valve] 122.3 70 56 10.4 35 5.5 5.5

2-M4 clamp screw

VQ5 VQZ VQD

(131.5)

Triangle mark indicator position Applicable connector: Flat ribbon cable connector (20P) (Conforming to MIL-C-83503)

12

12

EXH outlet

D side
C10: 3(R) port

Stations

U side
10

For top ported

C10: 1(P) port


A R 3 4 A 4 A 4 A 4 A 4 A 4 A 4 A 4

(58)

2 P 1

7.5

44.5 63.3 P = 17.5 2n-C4, C6, C8 (4(A), 2(B) port) C4: One-touch fitting for 4 C6: One-touch fitting for 6 C8: One-touch fitting for 8

Dimensions
L L1 L2 L3 L4 n 1 69.5 92 112.5 123 2 87 109.5 137.5 148 3 104.5 127 150 160.5

Formula: L1 = 17.5n + 52, L2 = 17.5n + 74.5 4 122 144.5 175 185.5 6 5 139.5 157 162 179.5 187.5 200 198 210.5 7 174.5 197 225 235.5 8 192 214.5 237.5 248 10 9 209.5 227 232 249.5 262.5 275 273 285.5

n: Stations (Maximum 16 stations) 13 279.5 302 325 335.5 15 14 297 314.5 319.5 337 350 362.5 360.5 373 16 332 354.5 375 385.5

12 11 244.5 262 267 284.5 287.5 312.5 298 323

2-3-35

25.5 41.5

39.5 21

62

18.5 37.6 53.6

A 4

B 2

1.TURN

2.PUSH

1.TURN

2.PUSH

SMC

Series

SQ2000

Kit (Terminal block box kit)

A compact terminal block is installed inside the box. G 3/4" female threads prepared for the electrical entry enables a conduit tube bracket to be connected. The maximum number of stations is 10 (16 option).

Manifold Specifications
Series Port location Porting specifications Port size 1(P), 3(R) 4(A), 2(B) C10 C4, C6, C8 Maximum number of stations 10 stations (16 as an option)

SQ2000
Us ide

Side, Top

12
Ds ide

tati

ons

2-G3/4" Electrical entry Valves are numbered from the D side.

Electrical wiring specifications


As the standard electrical wiring specifications, double wiring (connected to SOL. A and SOL. B) is adopted for the internal wiring of each station for 10 stations or less, regardless of valve and option types. Mixed single and double wiring is available as an option. For details, refer to page 2-3-54.

Terminal no. Polarity


SOL.A 1 station
1A 1B

1A SOL.B 1B SOL.A

() () () () () () () () () () () () () () () () () () () ()

(+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+)

Note) When using the negative common specifications, use valves for negative common.

1A 2A 3A 4A 5A 6A 7A 8A 9A 10A COM

2 stations

2A SOL.B 2B SOL.A

2A 3A 4A 5A 6A 7A 8A 9A 10A COM

1B 2B 3B 4B 5B 6B 7B 8B 9B 10B

2B 3B 4B 5B 6B 7B 8B 9B 10B

3 stations

3A SOL.B 3B SOL.A

4 stations

4A SOL.B 4B SOL.A

5 stations

5A SOL.B 5B SOL.A

6 stations

6A SOL.B 6B SOL.A

7 stations

7A SOL.B 7B SOL.A

8 stations

8A SOL.B 8B SOL.A

9 stations

9A SOL.B 9B SOL.A 10A 10B

10 stations

SOL.B

COM

(+)

()
Note)

Positive Negative common common specifications specifications

2-3-36

Plug-in Unit

Series

SQ2000

L4 L3 10 67 48.7 30 1 131.5 [Single, Double, Dual 3 port valve]


D side U side

L2 L1 P = 17.5

VQC
Indicator light 28.8 Manual override

SQ VQ0 VQ4

147 (3 position)

(131.5)

5.5

2-M4 Clamp screw


A
A 4

122.3

35

70 56

58 77

12 12

M5: External pilot port EXH outlet

D side
2-G3/4" Electrical entry C10: 3(R) port C10: 1(P) port

Stations

U side

18.5

For top ported

(77)

45 39.5 21

7.5

45.7

30 48.7

P = 17.5

2n-C4, C6, C8 (4(A), 2(B) port) C4: One-touch fitting for 4 C6: One-touch fitting for 6 C8: One-touch fitting for 8

Dimensions
L L1 L2 L3 L4 n 2 1 63.5 81 77.5 95 175 200 185.5 210.5

Formula: L1 = 17.5n + 46, L2 = 17.5n + 60 4 3 98.5 116 112.5 130 212.5 237.5 223 248 5 133.5 147.5 250 260.5 7 6 151 168.5 165 182.5 262.5 287.5 273 298 8 186 200 300 310.5 9 203.5 217.5 325 335.5 10 221 235 337.5 348

n: Stations (Maximum 16 stations) 12 256 270 375 385.5 13 273.5 287.5 387.5 398 14 291 305 412.5 423 15 308.5 322.5 425 435.5 16 326 340 437.5 448

11 238.5 252.5 350 360.5

25.5 41.5

2-3-37

62

10

37.6 53.6

B 2

1.TURN

2.PUSH

1.TURN

2.PUSH

VQ5 VQZ VQD

Series

SQ2000

Kit (Lead wire cable)

Direct electrical entry type

Manifold Specifications
Series Port location Side, Top Porting specifications Port size 1(P), 3(R) 4(A), 2(B) C10 C4, C6, C8 Maximum number of stations 12 stations
Us ide

SQ2000

e sid

12

st

atio

ns

Valves are numbered from the D side.

Wiring Specifications: Positive COM Specifications


Three lead wires are included per station regardless of valves used. Among the three lead wires, the red wire is for COM.

Wiring Specifications: Negative COM Specifications (Option)


Three lead wires are included per station regardless of valves used. Among the three lead wires, the black wire is for COM.

Lead wire color


SOL.A () SOL.B Black SOL.A () SOL.B COM. (+) Red () White

Lead wire color


Black SOL.A (+) COM. (+) Red () White SOL.B

Lead wire color


Red Black White SOL.B SOL.A (+) COM. () (+)

Lead wire color


Red Black White COM. () (+)

Single solenoid

Double solenoid Black: A side solenoid () Red: COM (+)

Single solenoid

Double solenoid Red: A side solenoid (+) Black: COM ()

Station number

Station number

24AWG x 3 core cable O.D. 1.5

White: B side solenoid () (Not used for single solenoid)

24AWG x 3 core cable O.D. 1.5

1
White: B side solenoid (+) (Not used for single solenoid)
Note) When using the negative common specifications, use valves for negative common.

2-3-38

Plug-in Unit

Series

SQ2000

L4
58 33.4 18
(Mounting hole 15.2 dimension)

5.25 Station number 47.8 30 1

L3 L2 L1 P = 17.5

Indicator light 28.8 Manual override

VQC SQ VQ0 VQ4

Electrical entry G1/2

147 (3 position) 131.5 [Single, Double, Dual 3 port valve]

10.4 5.5

AWG24 Lead wire

2-M4 clamp screw

VQ5 VQZ VQD

(131.5) 103.3

122.3

5.5

35

M5: External pilot port EXH outlet

12

12

D side
Lead wire length: L 0, 600 mm L 1, 1500 mm L2, 3000 mm C10: 3(R) port C10: 1(P) port

Stations

U side
10

For top ported

A R 3

18.5 37.6 53.6


B

70 56

(58) 39.5 21

2 P 1

7.5

30 48.7

P = 17.5

2n-C4, C6, C8 (4(A), 2(B) port) C4: One-touch fitting for 4 C6: One-touch fitting for 6 C8: One-touch fitting for 8

Dimensions
L L1 L2 L3 L4 n 1 63.5 77.5 100 110.5 2 81 95 125 135.5

Formula: L1 = 17.5n + 46, L2 = 17.5n + 60 n: Stations (Maximum 12 stations) 3 98.5 112.5 137.5 148 4 116 130 150 160.5 5 133.5 147.5 175 185.5 7 6 151 168.5 165 182.5 187.5 212.5 198 223 8 186 200 225 235.5 9 203.5 217.5 237.5 248 10 221 235 262.5 273 11 238.5 252.5 275 285.5 12 256 270 300 310.5

2-3-39

25.5 41.5

62

A 4

B 2

1.TURN

2.PUSH

1.TURN

2.PUSH

SMC

Series

SQ2000

Kit (Serial transmission unit)

The serial transmission system reduces wiring work, while minimizing wiring and saving space. The maximum number of stations is 8. (16 as an option). Only for type J2 and R2, the maximum stations are 4 (8 as an option).

Manifold Specifications
Series Port location Side, Top Porting specifications Port size 1(P), 3(R) 4(A), 2(B) C10 C4, C6, C8 Maximum number of stations 8 stations

SQ2000

3 12

tati

ons
Us ide

Stations are counted from station 1 on the D side. Double wiring (connected to SOL. A and SOL. B) is adopted for the internal wiring of each station, regardless of valve and option types. Mixed single and double wiring is available as an option. M3 screw
Item External power supply Current consumption (Inside unit) Specifications 24 VDC, +10%, 5% 0.1 A or less

Ds

ide

Corresponding SI unit output numbers and solenoid coils <Wiring example 1>
SI unit output no. 0 1 2 3 4 5 6 7 8 9

None

None

SI unit

Double

Double

Single

Single

Single

Stations

Double wiring (Standard)

<Wiring example 2>


Mixed wiring is available as an option. Specify the wiring specification by means of the manifold specification sheet. Refer to page 2-3-54 for details.
SI unit output no. 0 1 2 3 4 5 6 7

SI unit

Double

Double

Single

Single

Double

Stations

Mixed single and double wiring (Option)

2-3-40

Plug-in Unit

Series

SQ2000

Type SDF NKE Corporation Uni-wire System

Type SDH NKE Corporation Uni-wire H System

Type SDJ1, SDJ2 SUNX Corporation S-LINK System

VQC SQ
Name of terminal block, LED
ADDRESS
ON

ADDRESS
ON

DIP SW. POWER SEND


ON

POWER SEND

POWER SEND

VQ0
0 V 24 V

24 V 0 V

24 V 0 V

24 V 0 V

24 V 0 V

0 V 24 V

VQ4 VQ5 VQZ

LED

Description

LED

Description

LED

Description Light ON with power input Transmission indicator Normal: Blinks, Abnormal: Blinks slowly

Light ON with power input POWER (Light ON when normal, flickers when voltage is low) SEND Transmission indicator Normal: Blinks, Abnormal: Light OFF or ON

Light ON with power input POWER (Light ON when normal, flickers when voltage is low) Transmission indicator SEND Normal: Blinks, Abnormal: Light OFF or ON

POWER SEND

VQD

DG

DG

a) Type T branching multi-drop wiring (S-LINK System) Power 24 V supply { 0 V


24 V 0V D G D G 24 V 0V

b) Crossover wiring (Sensor link system)

Power 24 V supply { 0 V

Power 24 V supply { 0 V Transmission line

24 V 0V D G D G 24 V 0V

G D 0 V 24 V G D 0 V 24 V

G D 0 V 24 V G D 0 V 24 V

Power 24 V supply { 0 V Transmission line

Black White

Brown Blue Transmission line

Cable wiring

Main transmission Crimp connector SL-J1A line

The above is the example of using dedicated S-LINK flat ribbon cable SL-RCM00. Power 24 V supply { 0 V
24 V 0V D G D G 24 V 0V

Power 24 V supply { 0 V

Power 24 V supply { 0 V

24 V 0V D G D G 24 V 0V

Power 24 V supply { 0 V

DG

DG

Uni-wire System Send unit: SD-120 No. of output points, 16 points

Uni-wire H System Send unit: SD-H2 No. of output points, 16 points

S-LINK System S-LINK controller: SL-CU1 No. of output points, 16 points (Type SDJ1) No. of output points, 8 points (Type SDJ2)

Note

2-3-41

Series

SQ2000

Kit (Serial transmission unit)

Type SDQ OMRON Corporation DeviceNet, CompoBus/D

Type SDR1, SDR2 OMRON Corporation CompoBus/S System

Type SDV Mitsubishi Electric Corporation CC-LINK System

Name of terminal block, LED

SETTINGS PWR MOD/NET


ON

ADDRESS NO. PWR COM ERR


ON

PWR

L RUN

B RATE STATION NO.

L ERR. SD 24 V 0V V- CAM FG CAM Vt

RD

BS+ BDH BDL BS-

FG

24 V 0 V

24 V 0 V +24V 24G

DA

DB

DG

FG

LED

Description
Light OFF: When the unit is not online or circuit power is OFF

POWER Green light ON with circuit power input

LED Description POWER Light ON with transmission power input, light Off without it

LED

Description

Light ON with transmission power input, POWER light Off without it

Green light ON continuously: When the MOD/ unit is online and in operation NET Red light blinks: When a reversible abnormal transmission occurs Red light ON continuously: When irreversible abnormal transmission occurs or the same line is unable to go online

COMM OFF

Light ON with normal transmission, light with abnormal or standby transmission Light ON with abnormal transmission, ERR. light Off with normal or standby transmission

L RUN SD RD

Light ON when receiving normal data Light ON when sending data Light ON when receiving data
Light ON with transmission error/setting

L ERR. error, light blinks with changes in the


station no. or transmission speed setting

24 V 0 V V- CANL FG CANH V+

24 V 0 V V- CANL FG CANH V+

BS+ BDH BDL BS- 24 V 0 V

BS+ BDH BDL BS- 24 V 0 V

Cable wiring

Terminal resistor

VCANL FG CANH V+

BDH BDL

Connector With terminal resistor

Master

Master unit
DA DB DG SLD FG

SI unit
DA DB DG FG

SI unit
DA DB DG FG

Type 3 ground

Type 3 ground Type 3 ground

Branch crimped connectors

Twisted pair line with shielding

DeviceNet OMRON Corporation CompoBus/D System Master unit: C200HW-DRM21 No. of output points, 16 points

CompoBus/S System Master unit: C200HW-SRM21 Master unit: CQM1-SRM21

CC-LINK System Master unit: AJ61BT11 Master unit: A1SJ61BT11 Master unit: AJ61QBT11

Note

No. of output points, 16 points (Type SDR1) No. of output points, 8 points (Type SDR2)

Master unit: A1SJ61QBT11

No. of output points, 16 points

2-3-42

Terminal resistor

Plug-in Unit

Series

SQ2000

L4
5.25 L3 L2 L1 47.8 29
EX140-SMJ1

Indicator light

VQC SQ

58

M5: External pilot port

P = 17.5

28.8
Manual override

VQ0 VQ4

SERIAL UNIT

147 (3 position) 131.5 [Single, Double, Dual 3 port valve] 70 56 35 5.5 10.4

2-M4 clamp screw

(131.5)

5.5

12 12

EXH outlet

D side
C10: 3(R) port C10: 1(P) port

Stations

U side
10

For top ported

A R 3

(58) 39.5 21

2 P 1

7.5

76 95 P = 17.5

2n-C4, C6, C8 (4(A), 2(B) port) C4: One-touch fitting for 4 C6: One-touch fitting for 6 C8: One-touch fitting for 8

Dimensions
L L1 L2 L3 L4 n 1 69.5 123.5 150 160.5 2 87 141 162.5 173 3 104.5 158.5 187.5 198

Formula: L1 = 17.5n + 52, L2 = 17.5n + 106 4 122 176 200 210.5 5 139.5 193.5 225 235.5 6 7 157 174.5 211 228.5 237.5 250 248 260.5 8 192 246 275 285.5 9 209.5 263.5 287.5 298 10 227 281 312.5 323

n: Stations (Maximum 16 stations) 12 262 316 337.5 348 13 279.5 333.5 362.5 373 14 15 297 314.5 351 368.5 375 400 385.5 410.5 16 332 386 412.5 423

11 244.5 298.5 325 335.5

2-3-43

25.5 41.5

62

18.5 37.6 53.6

A 4

B 2

1.TURN

2.PUSH

1.TURN

2.PUSH

24V L ERR.SD PWR. 0V +24V 24G DA DB DG FG 1 10 L RUN B RATE STATION No. RD

VQ5 VQZ VQD

Series

SQ1000/2000

Manifold Option Parts for SQ1000


Blanking plate SSQ1000-10A-3
It is used by attaching on the manifold block for being prepared for removing a valve for maintenance reasons or planning to mount a spare valve, etc.

JIS Symbol
47 11.5

SUP/EXH block SSQ1000-PR-3-C8-


Option
Nil Description/Model Valve Single Stations 4 1 2 3 4 5

R S

Standard External pilot specifications Built-in silencer

For standard type manifolds, the SUP/EXH block is mounted on the D side. It is added to the manifold to increase SUP/EXH capacity. The number of SUP/EXH blocks that can be added is limited to two sets, one between manifold stations and another on the U side of the manifold due to the length of the internal lead wire. SUP/EXH blocks are not included in the number of manifold stations. D side
18

Option

Note) When specifying both options, indicate RS. Specify the spacer mounting position on the manifold specification sheet.

SUP/EXH block SSQ1000-PR-3-C8-

D side
3 (R) 1 (P)

Valve

Valve Valve SUP/EXH block U side


3 (R) 1 (P)

U side

BA

BA

BA

PR

Individual SUP spacer SSQ1000-P-3- C6


Port location
C6 Side ported L6 Top ported
This is used as a supply port for different pressures when using different pressures in the same manifold (for one station). Both sides of the station which is used with supply pressure from the individual SUP spacer are shut off. (Refer to application example.) Specify the spacer mounting position and SUP passage shut off positions on the manifold specification sheet. Two shut off positions are required per unit. (Two pieces of SUP block plate that shut off the supply pressure are included with the individual SUP spacer, therefore, it is not necessary to order them separately.) Electrical wiring is also connected to the manifold station with the individual EXH spacer. By changing the fitting shown in the drawing and the block plates, the spacers specification can be changed later (from the individual SUP spacer to the individual EXH spacer). The number of spacers is not limited when ordered with the manifold. However, when adding individual SUP spacers later, it is limited to two units, and another on the U side due to the length of the internal lead wire. Part number with manifold block: SSQ1000-P-3- C6 - M L6

Side ported
Stations 1 2 3 4 5

Description/Model Valve Option U side Single

Top ported D side

Individual SUP spacer SSQ1000-P-3-C6 L6 SUP shut off position: Specify 2 positions. SUP block plate (Ordering not required) Valve U side
3 (R) 1 (P)

SUP block plate (Ordering not required) D side


3 (R) 1 (P)

Valve Individual SUP spacer Valve

Manifold block

For top ported

BA
47 60

BA

BA

11.5

Individual SUP port One-touch fittings for 6

2-3-44

26

Plug-in Unit

Series

SQ1000/2000

Individual EXH spacer SSQ1000-R-3- C6


Port location
C6 Side ported L6 Top ported
This is used to exhaust an individual valve when the exhaust from a valve interferes with other stations in the circuit (used for one station). Both sides of the station which is to be individually exhausted are shut off. (Refer to application example.) Specify the spacer mounting position and EXH passage shut off positions on the manifold specification sheet. Two shut off positions are required per unit. (Two pieces of EXH block plate that shut off the exhaust are included with the individual EXH spacer, therefore, it is not necessary to order them separately.) Electrical wiring is also connected to the manifold station with the individual EXH spacer. By changing the fitting shown in the drawing and the block plates, the spacers specification can be changed later (from the individual EXH spacer to the individual SUP spacer). The number of spacers is not limited when ordered with the manifold. However, when adding individual EXH spacers later, it is limited to two units, one between manifold stations and another on the U side due to the length of the internal lead wire. Model no. with manifold block: SSQ1000-R-3- C6 - M L6

Side ported
Description/Model U side Valve Single Stations 1 2 3 4 5

Top ported

D side

Individual EXH spacer SSQ1000-R-3-C6 L6 EXH shut off position: Specify 2 positions.

Option

VQC SQ VQ0
EXH block plate (Ordering not required) Valve Valve U side
3 (R) 1 (P)

EXH block plate (Ordering not required) D side Manifold block


9
For top ported
3 (R) 1 (P)

VQ4 VQ5 VQZ VQD

Valve

Individual EXH spacer

60

11.5

Individual EXH port

One-touch fittings for 6

Individual SUP/EXH spacer SSQ1000-PR1-3- C6


Port location
C6 Side ported L6 Top ported

Side ported
Stations 1 2 3 4 5

37 47

BA

BA

BA

Description/Model Valve Option U side Single

This has both functions of the individual SUP and EXH spacers above. (Refer to application example.) Specify the spacer mounting position and SUP D side Top ported and EXH passage shut off positions on the manifold specification sheet. Two shut off positions each for SUP and EXH are required per unit. (Two pieces each of block plate that shut off the SUP and EXH passages are included with the individual SUP/EXH spacer.) Electrical wiring is also connected to the manifold station with the individual EXH spacer. By changing the fitting shown in the drawing Manifold block and the block plates, the spacers specification can be changed later. Individual EXH port The number of spacers is not limited when orOne-touch fittings for 6 dered with the manifold. However, when add- For top ported ing individual SUP/EXH spacers later, it is limited to two units, one between manifold stations and another on the U side due to the length of the internal lead wire. Model no. with manifold block: SSQ1000-PR1-3- C6 - M
60 L6 9 26 37 47

Individual SUP/EXH spacer SSQ1000-PR1-3-C6 L6 SUP shut off position: Specify 2 positions. EXH shut off position: Specify 2 positions.

Block plate Block plate (Ordering not required) (Ordering not required) Individual SUP EXH spacer Valve Valve Valve U side D side
3 (R) 1 (P) 3 (R) 1 (P)

BA

PR

BA

BA

11.5

Individual SUP port

One-touch fittings for 6

2-3-45

Series

SQ1000/2000
R P

Manifold Option Parts for SQ1000


SUP block plate SSQ1000-B-P
When supplying two different pressures, high and low, to one manifold, this is used between stations with different pressures. Also, it is used with an individual SUP spacer to shut off the air supply. Specify the station position on the manifold specification sheet. D side 5

6.5

<Shut off label>


When a SUP passage is shut off with a SUP block plate, a label is attached for external confirmation of the shut off position (one label each). Shut off labels are applied when SUP block plates are ordered with manifolds.

SUP passage U side O-ring

R P
SUP passage blocked

R P
SUP/EXH passage blocked

SSQ1000-B-R
When the exhaust from a valve interferes with other stations in the circuit, this is used between stations to separate exhausts. Also, it is used with an individual EXH spacer to shut off the exhaust of individual valves. Specify the station position on the manifold specification sheet. 8.5 D side 5

6.2

<Shut off label>


When an EXH passage is shut off with an EXH block plate, a label is attached for external confirmation of the shut off position (one label each). Shut off labels are applied when EXH block plates are ordered with manifolds.

EXH passage U side O-ring

R P
EXH passage blocked

R P
SUP/EXH passage blocked

Back pressure check valve [-B] SSQ1000-BP


This prevents cylinder malfunction caused by the exhaust from other valves. It is inserted into the R (EXH) port of the valve that is affected. It is especially effective when using single acting cylinders or exhaust center type solenoid valves. When installing back pressure check valves only on the stations required, enter the part number and specify the mounting stations on a manifold specification sheet. When installing back pressure check valves on all of the stations, indicate -B at the end of the manifold part number.

5.3

4.9

Caution
1. Although the back pressure check valve is an assembly part with a check valve mechanism, a small amount of air leakage is allowed. Therefore, take care not to restrict the exhaust air from the exhaust port. 2. The effective area of valves is about 20% less when the back pressure check valve is installed. 3. Since 4 port specification valves (5 (R1) and 3 (R2) are common) are used, back pressure cannot be prevented with dual 3 port valves.

2-3-46

3.6

EXH block plate

Plug-in Unit

Series

SQ1000/2000

Name plate [-N] SSQ1000-N3- Stations (1 to maximum)


This is a clear resin plate for applying solenoid valve function description labels, etc. To install, bend the plate slightly as shown and insert into the slots on the end plate side. Also, the plate is difficult to bend for manifolds with only a few stations, therefore, remove the silencer cover to install it. When ordering with manifolds, add -N at the end of the manifold number. Silencer cover P = 11.5

1 40.5

n: Stations

VQC SQ VQ0 VQ4

Blanking plug (For One-touch fitting) 23 KQ2P- 04 06 08


This is inserted into cylinder ports and SUP and EXH ports that are not used. Purchasing order is available in units of 10 pieces.

L A

Dimensions
Applicable fittings size d 3.2 4 6 8 Model KQ2P-23 KQ2P-04 KQ2P-06 KQ2P-08 A 16 16 18 20.5 L 31.5 32 35 39 D 3.2 6 8 10

VQ5 VQZ VQD

Port plug VVQZ100-CP


This is used to close the cylinder ports when changing a 5 port valve to a 3 port valve. Add A or B at the end of the valve part number when ordering with valves. Example) SQ1131-5-C6-A (N.O. specifications) 4 (A) port plug Example) SQ1131-5-C6-B (N.C. specifications) 2 (B) port plug Example) SQ1131-5-C6-B-M (B port plug with manifold block) O-ring B port A port 10 EXH outlet 9

Direct EXH outlet, built-in silencer [-S]


The EXH outlet is placed on the top side of the manifold end plate. The built-in silencer provides highly effective noise reduction. (Noise reduction of 30 dB) Note) Note that when excessive drainage occurs in the air supply, the drainage will be released along with the exhaust. Add S at the end of the manifold part number when ordering with manifolds. For precautions on handling and how to replace elements, refer to page 23-5.

2-3-47

Series

SQ1000/2000
External pilot port (M5 x 0.8) SUP/EXH block

Manifold Option Parts for SQ1000


External pilot specifications [-R]
This can be used when the air pressure is 0.1 to 0.2 MPa lower than the minimum operating pressure of the solenoid valves or used for vacuum specifications. Add R to the part numbers of manifolds and valves to indicate the external pilot specification. An M5 port will be installed on the top side of the manifolds SUP/EXH block. How to order valves (Example) SQ1130 R -5-C6 External pilot specifications How to order manifold (Example) Indicate R for an option. SS5Q13-08FD1-DR External pilot specifications Note 1) Not applicable for 4 position dual 3 port valves. Note 2) Indicate RY for low wattage types. Note 3) Valves with the external pilot specifications have a pilot EXH with individual exhaust specifications and EXH can be pressurized. However, the pressuresupplied from EXH should be 0.4 MPa or lower.

Dual flow fitting SSQ1000-52A- C8


Port size
C8 N9
8 5/16" C8: One-touch fittings for 8 N9: One-touch fittings for 5/16"

To drive a large bore cylinder, two valve stations are operated simultaneously to double the air flow. This fitting is used on the cylinder ports in this situation. Available sizes are 8 and 5/16" One-touch fittings. When ordering with valves, specify the valve part number without One-touch fitting and list without One-touch fitting and list the dual flow fitting part number. Example) Valve part number (without Onetouch fitting) SQ1131-5- C0 2 sets SSQ1000-52A- C8 1 set N9

22.8

2 B

This is inserted into the centralized type EXH port (One-touch fitting).

Applicable fittings size 8

Silencer (For EXH port)

24

39

29.5

77.8 59.3

SM

0 N2

Specifications
Series Model SQ1000 AN200-KM8 Effective area mm2 (Cv factor) 20 (1.1) Noise reduction (dB) 30

2-3-48

22

Plug-in Unit Manifold Option Parts for SQ2000


Blanking plate SSQ2000-10A-3
It is used by attaching on the manifold block for being prepared for removing a valve for maintenance reasons or planning to mount a spare valve, etc.

Series

SQ1000/2000

JIS Symbol
55.5

VQC
17.5

SQ
SUP/EXH block SSQ2000-PR-3-C10-
Option
Nil Description/Model Standard External pilot specifications Built-in silencer Valve Single Stations 4 1 2 3 4 5

VQ0 VQ4 VQ5 VQZ VQD

R S

Note) When specifying both options, indicate RS. Specify the spacer mounting position on the manifold specification sheet. For standard type manifolds, the SUP/EXH block is mounted on the D side. It is added to the manifold to increase SUP/EXH capacity. The number of SUP/EXH blocks that can be added is limited to two sets, one between manifold stations and another on the U side of the manifold due to the length of the internal lead wire. SUP/EXH blocks are not included in the number of manifold stations. U side

Option

SUP/EXH block SSQ2000-PR-3-C10-

D side
3 (R) 1 (P)

Valve

Valve Valve SUP/EXH block U side


3 (R) 1 (P)

D side
20

BA

BA

BA

PR

Individual SUP spacer SSQ2000-P-3- C8


Port location
C8 Side ported L8 Top ported
This is used as a supply port for different pressures when using different pressures in the same manifold (for one station). Both sides of the station which is used with supply pressure from the individual SUP spacer are shut off. (Refer to application example.) Specify the spacer mounting position and SUP passage shut off positions on the manifold specification sheet. Two shut off positions are required per unit. (Two pieces of SUP block plate that shut off the supply pressure are included with the individual SUP spacer, therefore, it is not necessary to order them separately.) Electrical wiring is also connected to the manifold station with the individual SUP spacer. By changing the fitting shown in the drawing and the block plates, the spacers specification can be changed later (from the individual SUP spacer to the individual EXH spacer). The number of spacers is not limited when ordered with the manifold. However, when adding individual SUP spacers later, it is limited to two units, and another on the U side due to the length of the internal lead wire. Model no. with manifold block: SSQ2000-P-3-C8 -M
L8

Side ported
Description/Model Valve U side Single Stations 1 2 3 4 5

Top ported

D side

Option

Individual SUP spacer SSQ2000-P-3- C8 L8 SUP shut off position: Specify 2 positions.

SUP block plate (Ordering not required) D side Manifold block


For top ported
3 (R) 1(P)

SUP block plate (Ordering not required) Valve U side


3 (R) 1 (P)

Valve

Individual SUP spacer Valve

10

BA
55.5 62

BA

BA

17.5

25.5 Individual SUP port

One-touch fitting for 8

2-3-49

Series

SQ1000/2000
Side ported
Stations 1 2 3 4 5

Manifold Option Parts for SQ2000


Individual EXH spacer SSQ2000-R-3- C8
Port location
C8 Side ported L8 Top ported
This is used to exhaust an individual valve when the exhaust from a valve interferes with other stations in the circuit (used for one station). Both sides of the station which is to be individually exhausted are shut off. (Refer to application example.) Specify the spacer mounting position and EXH passage shut off positions on the manifold specification sheet. Two shut off positions are required per unit. (Four pieces of EXH block plate that shut off the exhaust are included with the individual EXH spacer, therefore, it is not necessary to order them separately.) Electrical wiring is also connected to the manifold station with the individual EXH spacer. By changing the fitting shown in the drawing and the block plates, the spacers specification can be changed later (from the individual EXH spacer to the individual SUP spacer). The number of spacers is not limited when ordered with the manifold. However, when adding individual EXH spacers later, it is limited to two units, one between manifold stations and another on the U side due to the length of the internal lead wire. Model no. with manifold block: SSQ2000-R-3- C8 - M
L8

Description/Model Valve Option U side Single

Top ported

D side

Individual EXH spacer SSQ2000-R-3-C8 L8 EXH shut off position: Specify 2 positions. EXH block plate (Ordering not required) EXH block plate (Ordering not required) Valve U side
3 (R) 1 (P)

D side
3 (R) 1 (P)

Valve Individual EXH spacer Valve

For top ported

10

Manifold block

BA
55.5 62

BA

BA

17.5

41.5

Individual EXH port

One-touch fittings for 8

Individual SUP/EXH spacer SSQ2000-PR1-3- C8


Port location
C8 Side ported L8 Top ported
This has both functions of the individual SUP and EXH spacers above. (Refer to application example.) Specify the spacer mounting position and SUP and EXH passage shut off positions on the manifold specification sheet. Two shut off positions each for SUP and EXH are required per unit. [Block plates that shut off the SUP and EXH passages are included with the individual SUP/EXH spacer (2 pcs. of SUP block plate and 4 pcs. of EXH block plate).] Electrical wiring is also connected to the manifold station with the individual EXH spacer. By changing the fitting shown in the drawing and the block plates, the spacers specification can be changed later. The number of spacers is not limited when ordered with the manifold. However, when adding individual SUP/EXH spacers later, it is limited to two units, one between manifold stations on the U side due to the length of the internal lead wire. Model no. with manifold block: SSQ2000-PR1-3-C8 - M
L8

Side ported
Stations Description/Model U side Valve Single

1 2 3 4 5

Top ported
Option D side

Individual SUP/EXH spacer SSQ2000-PR1-3-C8 L8 SUP shut off position: Specify 2 positions. EXH shut off position: Specify 2 positions.

Block plate (Ordering not required) D side Manifold block


Individual EXH port
For top ported
3 (R) 1 (P)

Block plate (Ordering not required) Valve U side


3 (R) 1 (P)

Valve

Individual SUP EXH spacer Valve

One-touch fittings for 8

10

17.5

One-touch fitting for 8

2-3-50

25.5

Individual SUP port

41.5 55.5 62

BA

PR

BA

BA

Plug-in Unit

Series

SQ1000/2000

SUP block plate SSQ1000-B-R


When supplying two different pressures, high and low, to one manifold, this is used between stations with different pressures. Also, it is used with an individual SUP spacer to shut off the air supply. Specify the station position on the manifold specification sheet. 8.5 D side 5

6.2

VQC SQ

<Shut off label>


When a SUP passage is shut off with a SUP block plate, a label is attached for external confirmation of the shut off position (one label each). Shut off labels are applied when SUP block plates are ordered with manifolds. SUP passage U side O-ring

5 5.2 O-ring 9.4 8.3

VQ0 VQ4 VQ5 VQZ

R P R
SUP passage blocked

R P R
SUP/EXH passage blocked

EXH block plate SSQ2000-B-R


When the exhaust from a valve interferes with other stations in the circuit, this is used between stations to separate exhausts. Also, it is used with an individual EXH spacer to shut off the exhaust of individual valves. Specify the station position on the manifold specification sheet.

10 9.2

VQD

D side 4.6 EXH passage U side

<Shut off label>


When an EXH passage is shut off with an EXH block plate, a label is attached for external confirmation of the shut off position (one label each). Shut off labels are applied when EXH block plates are ordered with manifolds.

R P R
EXH passage blocked

R P R
SUP/EXH passage blocked

Back pressure check valve [-B] SSQ2000-BP


This prevents cylinder malfunction caused by the exhaust from other valves. It is inserted into the R (EXH) port of the valve that is affected. It is especially effective when using single acting cylinders or exhaust center type solenoid valves. When installing back pressure check valves only on the stations required, enter the part number and specify the mounting stations on a manifold specification sheet. When installing back pressure check valves on all of the stations, indicate -B at the end of the manifold part number.

Set of 2 pcs.

Caution
1. Although the back pressure check valve is an assembly part with a check valve mechanism, a small amount of air leakage is allowed. Therefore, take care not to restrict the exhaust air from the exhaust port. 2. The effective area of valves is about 20% less when the back pressure check valve is installed.

2-3-51

Series

SQ1000/2000

Manifold Option Parts for SQ2000


Name plate [-N] SSQ2000-N3- Stations (1 to maximum)
This is a clear resin plate for applying solenoid valve function description labels, etc. To install, bend the plate slightly as shown and insert into the slots on the end plate side. Also, the plate is difficult to bend for manifolds with only a few stations, therefore, remove the silencer cover to install it. When ordering with manifolds, add -N at the end of the manifold number. P = 17.5

1 53

n: Stations

Silencer cover

Blanking plug (For One-touch fitting) 04 KQ2P- 06 08 10


This is inserted into cylinder ports and SUP and EXH ports that are not used. Purchasing order is available in units of 10 pieces.

L A

Dimensions
Applicable fittings size d 4 6 8 10 Model KQ2P-04 KQ2P-06 KQ2P-08 KQ2P-10 A 16 18 20.5 22 L 32 35 39 43 D 6 8 10 12

Port plug VVQZ2000-CP


This is used to close the cylinder ports when changing a 5 port valve to a 3 port valve. Add A or B at the end of the valve part number when ordering with valves. Example) SQ2131-5-C8-A (N.O. specifications) 4 (A) port plug Example) SQ2131-5-C8-B (N.C. specifications) 2 (B) port plug Example) SQ2131-5-C8-B-M (B port plug with manifold block) B port O-ring 9.7

A port 14 EXH outlet

Direct EXH outlet, built-in silencer [-S]


The EXH outlet is placed on the top side of the manifold end plate. The built-in silencer provides highly effective noise reduction. (Noise reduction of 30 dB) Note) Note that when excessive drainage occurs in the air supply, the drainage will be released along with the exhaust. Add -S at the end of the manifold part number when ordering with manifolds. For precautions on handling and how to replace elements, refer to page 2-3-5.

2-3-52

Plug-in Unit

Series

SQ1000/2000

External pilot specifications [-R]


This can be used when the air pressure is 0.1 to 0.2 MPa lower than the minimum operating pressure of the solenoid valves or used for vacuum specifications. Add R to the part numbers of manifolds and valves to indicate the external pilot specifications. An M5 port will be installed on the top side of the manifolds SUP/EXH block. How to order valves (Example) SQ2130 R -5-C6 External pilot specifications How to order manifold (Example) Indicate R for an option. SS5Q23-08FD1-DR External pilot specifications

External pilot port (M5 x 0.8)

SUP/EXH block

VQC SQ VQ0 VQ4


Note 1) Not applicable for dual 3 port valves. Note 2) Indicate RY for low wattage types. Note 3) Valves with the external pilot specifications have a pilot EXH with individual exhaust specifications and EXH can be pressurized. However, the pressure supplied from EXH should be 0.4 MPa or lower.

VQ5 VQZ VQD

Dual flow fitting SSQ2000-52A- C10


Port size
C10 10 N11 3/8"
To drive a large bore cylinder, two valve stations are operated simultaneously to double the air flow. This fitting is used on the cylinder ports in this situation. Available sizes are 10 and 3/8" One-touch fittings. When ordering with valves, specify the valve part number without One-touch fitting and list without One-touch fitting and list the dual flow fitting part number. Example) Valve part number (without One-touch fitting) SQ2131-5 - C0 2 sets SSQ2000- 52A - C10 1 set N11 C10: One-touch fitting for 10 N11: One-touch fitting for 3/8"

29.3

This is inserted into the centralized type EXH port (One-touch fitting).

Applicable fittings size 10

Silencer (For EXH port)

24.7

44.2

38

80.8 59.6

SM

2 AN

00

Specifications
Effective area (mm2) Noise reduction (Cv factor) (dB) 26 (1.4) 30 SQ2000 AN200-KM10 Series Model

2-3-53

22

Series

SQ1000/2000

Manifold Option Parts for SQ1000/SQ2000


Special Wiring Specifications
In the internal wiring of F kit, P kit, J kit, T kit and S kit, double wiring (connected to SOL. A and SOL. B) is adopted for each station regardless of the valve and option types. Mixed single and double wiring is available as an option.

1. How to Order
Indicate option symbol -K in the manifold part number and be sure to specify station positions for single or double wiring on the manifold specification sheet. Also, specify wiring for spare connectors. (Up to two spare connectors are included depending on the remaining number of connector pins. When the wiring for the spare connectors is not specified, they will be wired according to Spare Connector Wiring on page 2-3-57.) Example) SS5Q13

- 09 FD0 - DKS
Others, option symbols: to be indicated alphabetically.

2. Wiring specifications
Connector terminal numbers are connected from solenoid station 1 on the A side in the order indicated by the arrows without skipping any terminal numbers.

COM.
26 14 15 16 17 18 19 20 21 22 23 24 25 1 2 3 4 5 6 7 8 9 10 11 12 13 24 22 20 18 16 14 12 10 8 6 4 25 23 21 19 17 15 13 11 9 7 5 3 1

COM.
1A 2A 3A 4A 5A 6A 7A 8A 9A 10A COM 1B 2B 3B 4B 5B 6B 7B 8B 9B 10B

COM.
20 18 16 14 12 10 8 6 4 2 19 17 15 13 11 9 7 5 3 1

COM.
20 18 16 14 12 10 8 6 4 2 19 17 15 13 11 9 7 5 3 1

COM.

COM. F kit D-sub connector (For 25P) P Kit Flat ribbon cable connector (For 26P) P Kit Flat ribbon cable connector (For 20P)

COM.

J kit Flat ribbon cable connector (20P) PC Wiring System compatible

T kit Terminal block (SQ2000 only)

For S kit (serial transmission kit), refer to pages 2-3-20 and 2-3-40.

3. Maximum stations
The maximum number of manifold stations is determined by the number of solenoids. Count one point for a single solenoid type and two points for a double solenoid type. Determine the number of stations so that the total number of solenoids is no more than the maximum points in the table below. F kit (D-sub connector) FD 25P 24 points P kit (Flat ribbon cable connector) PD 26P 24 points PDC 20P 18 points
J kit Flat ribbon cable PC Wiring System compatible T kit (Terminal block) SQ2000 only

Kit Type Max. points

S kit (Serial) SD 16 points

JD0 20P 16 points

TD0 20 points

Note) Maximum stations SQ1000: 24 stations SQ2000: 16 stations

2-3-54

Plug-in Unit

Series

SQ1000/2000

Special DIN Rail Length (DIN rail mounting (-D) only)


The standard DIN rail provided is approximately 30 mm longer than the overall length of the manifold with a specified number of stations. The following options are also available.

DIN rail length longer than the standard type (for stations to be added later, etc.)
In the manifold part number, specify -D for the manifold mounting symbol and add the number of required stations after the symbol. Example)

VQC SQ VQ0 VQ4 VQ5

SS5Q13-08FD0-D09BNK
Option symbols (alphabetically) DIN rail for 9 stations

8 station manifold

Ordering DIN rail only


DIN rail part number

AXT100-DR- n

Note) For n, enter a number from the No. line in the table below. For L dimension, refer to the dimensions of each kit.

VQZ VQD

L 1.25 P = 12.5 5.25 7.5

35

L Dimension
No. L dimension No. L dimension No. L dimension No. L dimension 1 23 11 148 21 273 31 398 2 35.5 12 160.5 22 285.5 32 410.5 3 48 13 173 23 298 33 423 4 60.5 14 185.5 24 310.5 34 435.5 5 73 15 198 25 323 35 448 6 85.5 16 210.5 26 335.5 36 460.5 7 98 17 223 27 348 37 473 8 110.5 18 235.5 28 360.5 38 485.5 9 123 19 248 29 373 39 498

5.5

25

L = 12.5 x n + 10.5

10 135.5 20 260.5 30 385.5 40 510.5

Direct Mounting Style (-E)


Manifold is mounted by using mounting holes of both sides of the manifold. DIN rail is not sticking out of the edge of end plate.

SQ1000
Mounting hole (For M4) Mounting hole (For M4)

SQ2000
Mounting hole (For M5)

1.TURN

2.PUSH

1.TURN

2.PUSH

A B

A B

A B

A B

1.TURN

2.PUSH

1.TURN

2.PUSH

Mounting hole (For M5)

2-3-55

Series

SQ1000/2000

Manifold Option for SQ1000/SQ2000


Negative Common Specifications
The following valve part numbers are for negative common specifications. Manifold part numbers are the same as the standard except L kit. Also, negative COM specifications are not available for the S kit.

How to order negative COM valves (Example)


SQ1130 N -5-C6
Negative common specifications

How to order negative COM manifold (Example) SS5Q13 - 08 LD1 N - D N


Stations Kit type Option DIN rail mounting style Negative common specifications

Inch-size One-touch Fittings


For One-touch fittings in inch sizes, use the following part numbers. Also, the color of the release button is orange.

How to order valves (Example) SQ1130- 5 Port location


Nil Side ported L Top ported

N7
Cylinder port
Symbol N1 Applicable tubing O.D. (Inch) 1/8" SQ1000 4(A), SQ2000 2(B) port N3 5/32" N7 1/4" N9 5/16"

How to order manifold (Example)


Add 00T at the end of the part number.

SS5Q13- 08 FD0 - DN - 00T


1 (P), 3 (R) port in inch size SQ1000: 5/16" (N9) SQ2000: 3/8" (N11)

2-3-56

Plug-in Unit How to Add Manifold Stations for SQ1000/SQ2000


1. Using Spare Connector to Add Stations

Series

SQ1000/2000

As shown in the table below, wiring specifications for spare connectors are based on to the remaining number of connector pins (remaining number of pins against the maximum number of solenoids for each kit.) The following steps are for using spare connectors to add stations.

Spare Connector Wiring


Remaining connector pins Spare connector wiring 4 pins or more 3 pins 2 pins 1 for double wiring 1 pin 1 for single wiring 0 pin None

VQC SQ VQ0 VQ4 VQ5 VQZ VQD

2 for double wiring 1 for double wiring (on the low no. station side) 1 for single wiring

What to order
Valves with manifold block (refer to pages 2-3-7 and 2-3-25) or the manifold blocks (Refer to page 2-3-58)>

Steps for adding stations


(1) Loosen the clamp screw on the U side end plate and open the manifold. (2) Mount the manifold block to be added. (3) Open the junction cover and attach the spare connector. Match the station position of the added station and the spare connector station number. (4) Press on the end plate to eliminate any space between the manifold blocks and tighten the clamp screw.
(Proper tightening torque: 0.8 to 1.0 Nm) Note 1) Order a manifold block with lead wire for the L kit because a spare connector is not included with the kit. (Refer to page 2-3-58.) Note 2) Do not let the lead wires get caught between manifolds, or when closing the junction cover.

D side (2) Manifold block (1)


Station number

5
U side

(3) Spare connector (1)


Junction cover

(4)

2-3-57

Series

SQ1000/2000

How to Add Manifold Stations for SQ1000/SQ2000


2. Adding Stations Without Required Spare Connectors
Spare connectors for 2 stations are initially included. However, to add 3 or more stations, order manifold blocks with lead wire in the tables below.

How to Order Manifold Blocks with Lead Wire SQ1000

SQ2000

SSQ1000
Lead wire type
F0 FS FW PS PW L0 L1 L2 SS SW

1A

FS 03

SSQ2000
Lead wire type
F0 FS FW PS PW TS TW L0 L1 L2 SS SW

1A

FS 03

Without lead wire (for using spare connectors to add stations) F kit (D-sub connector kit) Single wiring F kit (D-sub connector kit) Double wiring P, J kit (Flat ribbon cable kit) Single wiring P, J kit (Flat ribbon cable kit) Double wiring L kit (Lead wire kit) Lead wire length 0.6 m L kit (Lead wire kit) Lead wire length 1.5 m L kit (Lead wire kit) Lead wire length 3.0 m S kit (Serial transmission kit) Single wiring S kit (Serial transmission kit) Double wiring

Without lead wire (for using spare connectors to add stations) F kit (D-sub connector kit) Single wiring F kit (D-sub connector kit) Double wiring P, J kit (Flat ribbon cable kit) Single wiring P, J kit (Flat ribbon cable kit) Double wiring T kit (Terminal block kit) Single wiring T kit (Terminal block kit) Double wiring L kit (Lead wire kit) Lead wire length 0.6 m L kit (Lead wire kit) Lead wire length 1.5 m L kit (Lead wire kit) Lead wire length 3.0 m S kit (Serial transmission kit) Single wiring S kit (Serial transmission kit) Double wiring

Applicable stations
01 24
1 station

Option
Nil None Back pressure check valve External pilot specifications
Note) Enter -BR for both options.

24 station
Note 1) No symbol required for F0. Note 2) S kit is from 01 to 16

B R

Applicable stations
01 16
1 station

Option
Nil None Back pressure check valve External pilot specifications
Note) Enter -BR for both options.

16 stations
Note) No symbol required for F0.

B R

2-3-58

Plug-in Unit

Series

SQ1000/2000

3. Connection Method (Refer to page 2-3-57 regarding the steps for adding stations to a manifold block.)
Connect the round terminal of the red lead wire to the common terminal inside the junction cover.

(1) Connecting common terminals Connect lead wire assemblies included with manifold blocks as follows.

VQC SQ VQ0 VQ4 VQ5


Terminal screw Tightening torque 0.25 to 0.35 Nm

VQZ VQD
T, S kit

F, P, J kit

(2) Pulling out connector Pull out the connector to connect the lead wire. For F, P, and J kits, pull out and remove the housing while pressing down hard on the hook with a flat head screwdriver, etc. Remove the manual lever and lead wire cover, and pull out the connector. For T kits, remove the screws and pull out the terminal block. For S kits, remove the screws and pull out the connector.
Screw (Tightening torque 0.8 to 1.0 Nm)

Housing (F kit) (P, J kit)

Screw (Tightening torque 0.14 to 0.17 Nm) connector

Terminal block connector Manual lever Spring Hook Remove the stopper and pull out the connector. Housing Protrusion

Lead wire cover

Hook

F, P, J kit

T kit

S kit

2-3-59

Series

SQ1000/2000

How to Add Manifold Stations for SQ1000/SQ2000


(3) Connect the black and white lead wire pins to the positions shown below in accordance with each kit.

Caution 1. After inserting the pin, confirm that the pin hook is locked by lightly pulling the lead wire.
2. Do not pull the lead wire forcefully when connecting. Also, take care that lead wires do not get caught between manifolds or when closing the junction cover.

Wiring (F kit: D-sub connector kit)


Procedure) Based on the manifold specifications, station 1 of SOL.A (black wire) will be terminal number 1 of the D-sub connector, and for station 2 and thereafter, connect black wires, then white wires in the order as shown below by the arrows.
Lead wire assembly Connector terminal no. Station 1 Black, SOL. A
14

1 2 3 4 5 6 7 8 9

14 15 16 17 18 19 20 21 22 23 24 25

Station 2 Black, SOL. A Station 3 White, SOL. B Station 4 White, SOL. B 1 station Station 5 White, SOL. B 2 stations 3 stations SOL.A SOL.A SOL.A SOL.B SOL.A 4 stations SOL.B SOL.A 5 stations 6 stations COM SOL.B Terminal Lead wire no. color 1 14 2 15 3 16 4 17 5 Black Black Black White Black White Black White Black

Station 3 Black, SOL. A Station 4 Black, SOL. A Station 5 Black, SOL. A Station 6 Black, SOL. A

10

13 12

Black

11

Red (COM) White Hook

25

24

23

22

21

20

19

18

17

16

15

10 11 12 COM 13

Manifold Specifications Example


Stations 1 Single wiring Double wiring 2 3 4 5 6

The drawing above shows connections based on the manifold specifications example in the table to the left.

13

Red

Wiring (P kit: Flat ribbon cable kit)


Procedure) Based on the manifold specifications, station 1 of SOL.A (black wire) will be terminal number 1 of the D-sub connector, and for station 2 and thereafter, connect black wires, then white wires in the order as shown below by the arrows.
Terminal no. Protrusion Lead wire assembly Station 2 Black, SOL. A Station 3 White, SOL. B Station 4 White, SOL. B Station 5 White, SOL. B 1A 2A 3A 4A 5A 6A 7A 8A 9A 10A Red (COM) 11A 12A 1B 2B 3B 4B 5B 6B 7B 8B 9B 10B 11B 12B 13B Red (COM) 6 stations SOL.A COM COM SOL.A 5 stations SOL.B SOL.A 4 stations SOL.B Station 1 Black, SOL. A Station 3 Black, SOL. A Station 4 Black, SOL. A 1 station Station 5 Black, SOL. A 2 stations Station 6 Black, SOL. A 3 stations SOL.A SOL.A SOL.A SOL.B Terminal Lead wire no. color Black 1B 1A 2B 2A 3B 3A 4B 4A 5B 13A 13B Black Black White Black White Black White Black Red Red

Manifold Specifications Example


Stations 1 Single wiring Double wiring 2 3 4 5 6

Red (COM)

13A

The drawing above shows connections for type 26P flat ribbon cable connector based on the manifold specifications example in the table to the left. For type 20P, the connection will be the same as above except that COM changes to 10A and 10B.

2-3-60

Plug-in Unit

Series

SQ1000/2000

Wiring (J kit: Flat ribbon cable kit, PC Wiring System compatible)


Procedure) Based on the manifold specifications, station 1 of SOL.A (black wire) will be terminal number 10A of the flat ribbon cable connector, and for station 2 and thereafter, connect black wires, then white wires in the order as shown below by the arrows.
Terminal no. Protrusion Red (COM) Lead wire assembly Unused Station 5 White Station 5 Black Red (COM) Station 4 White Station 4 Black Station 3 White Station 3 Black Station 2 Black Station 1 Black 1A 2A 3A 4A 5A 6A 7A 8A 9A 10A 1B 2B 3B 4B 5B 6B 7B 8B 9B 10B Station 6 Black 5 stations 6 stations 4 stations 1 station 2 stations 3 stations Red (COM) Unused SOL.A SOL.A SOL.A SOL.B SOL.A SOL.B SOL.A SOL.B SOL.A COM COM Terminal Lead wire no. color 10A 9A 8A 7A 6A 5A 4A 3A 10B 1A 1B Black Black Black White Black White Black White Black Red Red

VQC SQ VQ0 VQ4 VQ5 VQZ VQD

Manifold Specifications Example


Stations 1 Single wiring Double wiring 2 3 4 5 6

Wiring (T kit: Terminal block kit)


Procedure) Based on the manifold specifications, connect to the housing according to the wiring example below.
Housing Single wiring
1

A
1 2 3

B
4

White SOL.B Red COM. Black SOL.A

Insert to the locking position.

Manifold Specifications Example


Stations 1 Single wiring Double wiring 2 3 4 5 6

10

Lead wire assembly

Black Red Black Red A Double wiring


1 2 3

B
4

Lead wire Terminal color no. 1 station 2 stations SOL.A COM SOL.A COM SOL.A COM SOL.A COM SOL.B SOL.A COM SOL.B SOL.A COM Black Station 1: 1 Red Station 1: 2 Black Station 1: 3 Red Station 1: 4 Black Station 2: 1 Red Station 2: 2 Black Station 2: 3 Red Station 2: 4 White Station 3: 1 Black Station 3: 3 Red Station 3: 4 White Station 4: 1 Black Station 4: 3 Red Station 4: 4

Black Red White Unused

AB

Stations for all double 3 stations wiring Station 1 Station 2 4 stations Station 3 Station 4 Station 5 Station 6 5 stations Station 7 Station 8 Station 9 Station 10 6 stations

Connector no.

2-3-61

Series

SQ1000/2000

How to Add Manifold Stations for SQ1000/SQ2000


Wiring (S kit: Serial transmission kit)
Procedure) Based on the manifold specifications, station 1 of SOL.A (black wire) will be terminal number 1 of the serial connector, and for station 2 and thereafter, connect black wires, then white wires in the order as shown below by the arrows.
Connector terminal no.

Lead wire assembly

Station 1 Black, SOL. A Station 3 Black, SOL. A Station 4 Black, SOL. A Station 5 Black, SOL. A Station 6 Black, SOL. A

1 3 5 7 9 11 13

2 4 6 8 10

Station 2 Black, SOL. A Station 3 White, SOL. B Station 4 White, SOL. B 1 station Station 5 White, SOL. B 2 stations 3 stations Terminal Lead wire no. color SOL.A SOL.A SOL.A SOL.B SOL.A 1 2 3 4 5 6 7 8 9 17 18

Black Black Black White


Black White Black White Black Red Red

12 14 16 18 COM Red 5 stations 6 stations 4 stations

SOL.B SOL.A SOL.B SOL.A COM

Red (COM) COM Red

15 17

Manifold Specifications Example


Stations 1 Single wiring Double wiring 2 3 4 5 6 The drawing above shows connections based on the manifold specifications example in the table to the left.

COM

2-3-62

VQC SQ VQ0 VQ4 VQ5 VQZ VQD

2-3-63

Series

SQ1000/2000
Rubber seal type Single: SQ1131
e q w
SQ1130
(A) (B) 42

Construction: Series SQ1000 Plug-in Type Main Parts and Pilot Valve Assembly
Metal seal type Single: SQ1130
r

w
SQ1131
(A) (B) 4 2

5 13 (R1) (P)(R2)

5 13 (R1) (P) (R2)

Double (Latching): SQ1230


t e q w
SQ1230
(A) (B) 42

Double (Latching): SQ1231


t e q w
SQ1231
(A) (B) 4 2

5 13 (R1) (P)(R2)

513 (R1) (P) (R2)

Double (Double solenoid): SQ1230D


y e q w e
SQ1230D
(A) (B) 42

Double (Double solenoid): SQ1231D


y e q w e
SQ1231D
(A) (B) 42

51 3 (R1)(P)(R2)

5 13 (R1) (P) (R2)

u
3

3 position: SQ1 4 30 5
SQ1330

3 position: SQ1 4 31 5
SQ1331
(A)(B) 42

e q

q w e
SQ1431

(A)(B) 42

513 (R1) (P)(R2)

5 13 (R1) (P)(R2) (A)(B) 42

SQ1430
(A)(B) 42

51 3 (R1) (P)(R2)

513 (R1) (P)(R2)

SQ1530

SQ1531

(A) (B) 4 2

(A) (B) 4 2

513 (R1) (P)(R2)

5 13 (R1)(P)(R2)

Dual 3 port valve: SQ1 B 31 C Component Parts


No. q w e Body Spool/Sleeve Spool Piston Description Material Zinc die-casted Stainless steel (Metal seal) Aluminum (Rubber seal) Resin

SQ1A31
4 2

e w q

e
SQ1B31

N.C.
4

N.C.
2

Pilot Valve Assembly Note)


No. r t y u For single For double (Latching) Model

u
SQ13
VQ110S
(K) (Y) 5 6 5

N.O.
SQ1C31
4

N.O.
2

- 6 (N)J11(B)

N.C.

N.O.

VQ110SL- J12 Negative COM: VQ110SN- 5 J12 6

For double (Double solenoid) on A side VQ110S (K)- 5 (N)J13(B) (Y) 6 For 3P, Dual 3 port on A side For double (Double solenoid) on B side VQ111S (K)- 5 (N)J14 (Y) 6 For 3P, Dual 3 port on B side
Note) Nil: Standard B : Locking type manual override N : Negative COM specifications Y : Low wattage specifications

2-3-64

Plug-in Unit

Series

SQ1000/2000

Construction: Series SQ2000 Plug-in Type Main Parts and Pilot Valve Assembly
Metal seal type Single: SQ2130
r e q w
SQ2130
(A) (B) 42

Rubber seal type Single: SQ2131


r e q w
SQ2131
(A) (B) 42

51 3 (R1) (P)(R2)

51 3 (R1) (P)(R2)

VQC SQ

Double (Latching): SQ2230


t e qw
SQ2230
(A)(B) 42

Double (Latching): SQ2231


t e q w
SQ2231
(A)(B) 42

VQ0 VQ4 VQ5 VQZ

51 3 (R1) (P)(R2)

51 3 (R1) (P)(R2)

Double (Double solenoid): SQ2230D


y e q we
SQ2230D
(A)(B) 42

Double (Double solenoid): SQ2231D


y e q w e
SQ2231D
(A)(B) 42

VQD

51 3 (R1)(P)(R2)

51 3 (R1) (P)(R2)

u
3 5

3 position: SQ2 4 30
SQ2330

3 position: SQ2 4 31
5

e q

(A)(B) 42

SQ2331

e q

e
SQ2431

(A)(B) 42

513 (R1) (P)(R2)

513 (R1) (P)(R2) (A)(B) 42

SQ2430

(A) (B) 42

51 3 (R1) (P)(R2)

51 3 (R1)(P)(R2)

SQ2530

(A) (B) 4 2

SQ2531

(A) (B) 4 2

u
513 (R1) (P)(R2)

u
513 (R1)(P)(R2)

Dual 3 port valve:


y

A SQ2 B 31 C

ewq

w e

SQ2A31

2 3 N.C. 2 3 N.O. 2 3 N.O.

Component Parts
No. q w e Body Spool/Sleeve Spool Piston Description Material Aluminum die-casted Stainless steel (Metal seal) Aluminum (Rubber seal) Resin

5 N.C.

SQ2B31

5 N.O.

SQ2C31

u
5 N.C. 1

Pilot Valve assembly Note)


No. r t y u For single For double (Latching) For double (Double solenoid) on A side Model

SQ2
5

VQ111S(Y)- 6 (N)J31 VQ110SL- 5 J32 6 Negative COM: VQ110SN- 6 J32


5 5

VQ111S(Y)- 6 (N)J23 For 3P, Dual 3 port on A side For double (Double solenoid) on B side VQ111S(Y)- 5 (N)J34 6 For 3P, Dual 3 port on B side
Note) Nil: Standard N : Negative COM specifications Y : Low wattage specifications

2-3-65

Series

SQ1000/2000
SUP/EXH block assembly Valve and manifold block assembly U side end plate assembly

Exploded View of Manifold: SQ1000 (Plug-in Type Manifold) SS5Q13


(F, P, J, L, S kit)
D side end plate assembly

F kit

y !3 q

P kit (26P/20P) J kit (20P) P (J) kit

i !3 !2

!1 L kit !0

EX SERI 14 AL 0-SC UN S1 IT

AD

DR

ES

S No

t S kit

2-3-66

Plug-in Unit Manifold Spare Parts

Series

SQ1000/2000

Refer to pages 2-3-58 to 62 of How to Add Manifold Stations regarding the mounting of each spare parts.

<q w e r D side end plate assembly>

Stations
01
For 1 station

Manifold mounting
Nil E
DIN rail mount style Direct mount style

Wiring specifications Electrical entry


F P PC J Nil S F kit P kit (26P) P kit (20P) J kit (20P) L kit S kit q w e r O S W
Without lead wire Single wiring Double wiring

24 For 24 stations
Note) The maximum number of stations will be different depending on the wiring specifications.

SSQ1000

3A

VQC SQ

<t SI unit>
Manifold SDF kit SDH kit SDJ1 kit SDJ2 kit SDQ kit SDR1 kit SDR2 kit SDV kit No. EX140-SUW1 EX140-SUH1 EX140-SSL1 EX140-SSL2 EX140-SDN1 EX140-SCS1 EX140-SCS2 EX140-SMJ1

<o Element>

VQ0

Description NKE Corp.: Uni-wire System (16 output points) NKE Corp.: Uni-wire H System (16 output points) SUNX Corp.: S-LINK System (16 output points) SUNX Corp.: S-LINK System (8 output points) DeviceNet, CompoBus/D (OMRON Corp.) (16 output points) OMRON Corp.: CompoBus/S System (16 output points) OMRON Corp.: CompoBus/S System (8 output points) Mitsubishi Electric Corp.: CC-LINK System (16 output points)

SSQ1000

Note) Part number for a 10 piece set of element. For replacement procedures, refer to page 2-3-5.

SE

VQ4 VQ5 VQZ VQD

<!0 Port plug>

VVQZ2000 CP
<!1 Fitting assembly>
(For P, R port)

<y U side end plate assembly>


(For F, P, J, S kit)

VVQ1000
Port size
C6 C8 N7 N9

51A

C8

SSQ1000
(For L kit)

2A 2A

3 3
Nil E

1 2
Manifold mounting
DIN rail mount style Direct mount style

SSQ1000

One-touch fitting for 6 One-touch fitting for 8 One-touch fitting for 1/4" One-touch fitting for 5/16"
Note) Purchasing order is available in units of 10 pieces

<u SUP/EXH block assembly>

< !2 Fitting assembly>


(For cylinder port)

SSQ1000
Port size
C8 N9

PR 3

C8
Option
Nil R S Common exhaust type External pilot Built-in silencer, direct exhaust

VVQ1000
Port size
C3 C4 C6 M5 N1 N3 N7

50A

C3

One-touch fitting for 8 One-touch fitting for 5/16"

<i Manifold block assembly>

Note) Enter -RS for both options.

SSQ1000
Lead wire type
F0 Without lead wire FS Single wiring

1A

F0 01
Option
Nil

Including gaskets !3

One-touch fitting for 3.2 One-touch fitting for 4 One-touch fitting for 6 M5 thread One-touch fitting for 1/8" One-touch fitting for 5/32" One-touch fitting for 1/4"
Note) Purchasing order is available in units of 10 pieces

F kit: D-sub connector kit F kit: D-sub connector kit P kit: Flat ribbon cable kit Single wiring

FW Double wiring

B R

None Back pressure check valve External pilot specifications


Note) Enter -BR for both options.

< !3 Gasket and screw assembly>

SQ1000 GS
Note) Part number for 10 pieces each of gaskets and screws.

PS

J kit: PC Wiring System compatible Single wiring P kit: Flat ribbon cable kit Double wiring

Applicable stations (For F, P, J, S kit)


01
Station 1

J kit: PC Wiring System compatible Double wiring

24 Station 24
Note 1) No symbol required for F0. Note 2) Specify from 01 to 16 for S kit.

L kit: Lead wire kit L0 Lead wire length 0.6 m

L1 Lead wire length 1.5 m L2


L kit: Lead wire kit Lead wire length 3 m S kit: Serial transmission kit

L kit: Lead wire kit

SS Single wiring

SW S kit: Serial transmission kit Double wiring

PW

2-3-67

Series

SQ1000/2000

Exploded View of Manifold: SQ2000 (Plug-in Type Manifold) SS5Q23


(F, P, J, T, L, S kit)
D side end plate assembly SUP/EXH block assembly Valve and manifold block assembly U side end plate assembly

F kit

q i
P kit (26P/20P) J kit (20P)

!4

P (J) kit

o !0 w !4 !3

e !2 T kit !1

L kit

SE EX 140

RIA

-SC

L UN IT S1

AD

DR

ES

S No

y S kit

2-3-68

Plug-in Unit Manifold Spare Parts

Series

SQ1000/2000

Refer to pages 2-3-58 to 62 of How to Add Manifold Stations regarding the mounting of each spare parts.

<q w e r t D side end plate assemblies>

Stations
01
For 1 station

Manifold mounting
Nil E
DIN rail mount style Direct mount style

Electrical entry
F P PC J Nil S F kit P kit (26P) P kit (20P) J kit (20P) L kit S kit q w e r

Wiring specifications
O S W
Without lead wire Single wiring Double wiring

16 For 16 stations
Note) The maximum number of stations will be different depending on the wiring

SSQ2000

3A

VQC SQ

<y SI unit>
Manifold SDF kit SDH kit SDJ1 kit SDJ2 kit SDQ kit SDR1 kit SDR2 kit SDV kit No. EX140-SUW1 EX140-SUH1 EX140-SSL1 EX140-SSL2 EX140-SDN1 EX140-SCS1 EX140-SCS2 EX140-SMJ1 Description NKE Corp.: Uni-wire System (16 output points) NKE Corp.: Uni-wire H System (16 output points) SUNX Corp.: S-LINK System (16 output points) SUNX Corp.: S-LINK System (8 output points) DeviceNet, CompoBus/D (OMRON Corp.) (16 output points) OMRON Corp.: CompoBus/System (16 output points) OMRON Corp.: CompoBus/System (8 output points) Mitsubishi Electric Corp.: CC-LINK System (16 output points)

<!0 Element>

VQ0

SSQ2000
<!1 Port plug>

SE

Note) Part number for a 10 piece set of element. For replacement procedure, refer to page 2-3-5.

VQ4 VQ5 VQZ VQD

VVQZ3000 CP
<!2 Fitting assembly>
(For P, R port)

<u U side end plate assembly>


(For F, P, J, T, S kit)

VVQ2000
Port size

51A

C8

SSQ2000
(For L kit)

2A 2A

3 3
Nil E

1 2
Manifold mounting
DIN rail mount style Direct mount style

SSQ2000

One-touch fitting for 8 C8 C10 One-touch fitting for 10 N9 One-touch fitting for 5/16" N11 One-touch fitting for 3/8"
Note) Purchasing order is available in units of 10 pieces

<i SUP/EXH block assembly>

<!3 Fitting assembly>


(For cylinder port) Option
Nil R S Common exhaust type External pilot Built-in silencer, direct exhaust

SSQ2000
Port size

PR 3

C8

VVQ1000
Port size
C4 C6 C8 N3 N7 N9 01

51A

C4

One-touch fitting for 8 C8 One-touch fitting for 10 C10 N9 One-touch fitting for 5/16" N11 One-touch fitting for 3/8"

Note) Enter -RS for both options.

<o Manifold block assembly>

SSQ2000
Lead wire type
F0 Without lead wire FS Single wiring

1A

F0 01
Option
Nil

Including gaskets !3

One-touch fitting for 4 One-touch fitting for 6 One-touch fitting for 8 One-touch fitting for 5/32" One-touch fitting for 1/4" One-touch fitting for 5/16 Rc 1/8 thread
Note) Purchasing order is available in units of 10 pieces

F kit: D-sub connector kit F kit: D-sub connector kit P kit: Flat ribbon cable kit Single wiring J kit: PC Wiring System compatible Single wiring P kit: Flat ribbon cable kit Double wiring J kit: PC Wiring System compatible Double wiring T kit: Terminal block kit Single wiring T kit: Terminal block kit Double wiring L kit: Lead wire kit Lead wire length 0.6 m L kit: Lead wire kit Lead wire length 1.5 m L kit: Lead wire kit Lead wire length 3 m S kit: Serial transmission kit Single wiring S kit: Serial transmission kit Double wiring

FW Double wiring PS

B R

None Back pressure check valve External pilot specifications

<!4 Gasket and screw assembly>

Note) Enter -BR for both options.

SQ2000 GS
Note) Part number for 10 pieces each of gaskets and screws.

Applicable stations
01
Station 1

PW TS TW L0 L1 L2 SS SW

16 Station 16
Note 1) No symbol required for F0.

2-3-69

For details about certified products conforming to international standards, visit us at www.smcworld.com.

Series SQ1000

Plug Lead Unit


How to Order Manifold

SS5Q14

08 FD2

D
Option
Nil None

Stations
01 24
Note)

1 station 24 stations
Note) The maximum number of stations depends on the type of electrical entries.

02 to 24(1) DIN rail length specified B Back pressure check valve K (2) Special wiring specifications (Except double wiring) N With name plate (Side ported only) R External pilot specifications S Built-in silencer, direct exhaust
Note 1) For specifying DIN rail length, indicate D. (Enter the number of stations inside .) Example: -D08 Note 2) Standard wiring specification are for double wiring. Indicate wiring specifications for single wiring or mixed single and double wiring, or when exceeding the standard maximum number of stations. (Except C kit) Note 3) For specifying two or more options, enter them alphabetically. Example: -BKN

Manifold mounting
D DIN rail mount style Note) E Direct mount style
Note) C kit of SQ2000 only.

Electrical entry
Kit type Lead wire connector location U side Cable specifications D-sub connector (25P) kit, without cable D side D-sub connector (25P) kit, with 1.5 m cable D-sub connector (25P) kit, with 3.0 m cable D-sub connector (25P) kit, with 5.0 m cable Flat ribbon cable (26P) kit, without cable
(1)

Station

Max. number of stations for special wiring specifications

(2)

Max. number of solenoids

F kit
D side D-sub Connector kit

P kit

Flat ribbon cable connector kit

( 26P ) 20P

FD0 FD1 FD2 FD3 PD0 PD1 PD2 PD3 PDC

1 to 12 stations

24 stations

24

Flat ribbon cable (26P) kit, with 1.5 m cable Flat ribbon cable (26P) kit, with 3.0 m cable Flat ribbon cable (26P) kit, with 5.0 m cable Flat ribbon cable (20P) kit, without cable 1 to 9 stations 18 stations 18 1 to 12 stations 24 stations 24

D side

J kit
JD0
Flat ribbon cable (20P) (PC Wiring System compatible) D side Flat ribbon cable (20P) PC Wiring System compatible 1 to 8 stations 16 stations 16

C kit
C
Connector kit
Note 1) Separately order the 20P type cable assembly for the P kit. Note 2) The maximum number of stations should not be more than the maximum number of solenoids. (The number of solenoids are counted as: 1 for single solenoids and 2 for type 3P and 4P double solenoids.)

Connector kit

1 to 24 stations

2-3-70

Plug Lead Unit

Series

SQ1000

How to Order Valves

SQ1 1 4 0
Type of actuation
2 position single
(A) (B) 42

5 L

C6
With/Without manifold block
Nil Without manifold block M With manifold block MB With manifold block, built-in back pressure check valve

513 (R1)(P)(R2)

2 position double (Latching)


(A) (B) 42 (A) (B) 42

VQC SQ VQ0

51 3 (R1)(P)(R2)

51 3 (R1)(P)(R2)

Metal seal
(A) (B) 42

Rubber seal
(A) (B) 42

2 position double (Double solenoid)(1)

51 3 (R1)(P)(R2)

51 3 (R1)(P)(R2)

Lead wire is not included. Lead wire is not included. When ordering with manifolds When only valves are required.

VQ4 VQ5 VQZ VQD

Metal seal
(A) (B) 42

Rubber seal

3 position closed center

For adding stations

513 (R1)(P)(R2)

3 position exhaust center

(A) (B) 42

Port plug mounting port


Nil None Port 4(A) Port 2(B)

513 (R1)(P)(R2)

3 position pressure center

(A) (B) 42

A B

513 (R1)(P)(R2)

Cylinder port
C3 C4 C6 M5 L3 L4 L6 L5
One-touch fitting for 3.2 One-touch fitting for 4 One-touch fitting for 6 M5 thread One-touch fitting for 3.2 One-touch fitting for 4 One-touch fitting for 6 M5 thread
Note) Can be changed to side ported configuration.

4 position dual 3 port valve


(2)
(A) 4 5 (R1) (B) 2 3 (R2)

Side ported

1 (P)

N.C.
(2)
(A) 4 5 (R1)

N.C.
(B) 2 3 (R2)

4 position dual 3 port valve

1 (P)

Top ported

Note)

N.O.
(2)
(A) 4 5 (R1)

N.O.
(B) 2 3 (R2)

4 position dual 3 port valve

1 (P)

Manual override
Nil Non-locking push type (Tool required)

N.C.

N.O.

B Note)
Locking type (Tool required)

Note 1) For double solenoid specifications, the function symbol below is D. Note 2) Only rubber seal types are applicable.

Seal
0 1
Metal seal Rubber seal

Function
Nil Standard type (1.0 W DC) 2 position double (Double solenoid specifications)
(1)

Note) Except double (latching) type.

D K

High pressure type (1.0 MPa, 1.0 W DC) [Applicable to metal seal only] Negative COM Low wattage type (0.5 W DC) External pilot specifications
Note 1) Except double (latching) type. Note 2) Except dual 3 port valves. Note 3) When two or more symbols are specified, indicate them alphabetically.

Electrical entry
L
Plug connector type With 300 mm lead wire

LO
Plug connector type without connector

N Y (1) R (2)

Coil voltage
5 6
24 VDC 12 VDC
Note) For F, P, J kit manifolds

Note) Light/Surge voltage suppressor is built-in.

Note) Indicate LO when ordering centralized wiring type manifolds, F, P, and J kits, since the lead wire will be attached to the manifold side.

2-3-71

Series

SQ1000
P. 2-3-98 Individual SUP/EXH spacer P. 2-3-99 Name plate (-N) P. 2-3-101 External pilot P. 2-3-102

Manifold Option
Blanking plate

SSQ1000-10A-4

SSQ1000-PR1-4- C6 L6

SSQ1000-N3-n

specifications (-R)
External pilot port

SUP/EXH block

P. 2-3-98 SUP block plate

P. 2-3-100 Blanking plug

P. 2-3-101 Dual flow fitting

P. 2-3-102

SSQ1000-PR-4-C8 (-S)

SSQ1000-B-P
R P

KQ2P-23/04/06/08

SSQ1000-52A- C8 N9

D side

U side

Individual SUP spacer P. 2-3-98 EXH block plate

P. 2-3-100 Port plug

P. 2-3-101 Silencer

P. 2-3-102

SSQ1000-P-4- C6 L6

SSQ1000-B-R
R P

VVQZ100-CP

(For EXH port)

D side

SM

AN

20

U side

Individual EXH spacer P. 2-3-99 Back pressure check valve (-B) SSQ1000-R-4-C6 L6

P. 2-3-100 Built-in silencer (-S) P. 2-3-101 Special wiring

P. 2-3-108
Terminal no. SOL.A SOL.A SOL.A SOL.A SOL.A SOL.B SOL.A SOL.B SOL.A SOL.B SOL.A SOL.B COM. 1 () 14 () 2 () 15 () 3 () 16 () 4 () 17 () 5 () 18 () 6 () 19 () 13 (+)

specifications (-K)
D-sub connector 1 station 2 stations 3 stations 4 stations 5 stations 6 stations 7 stations 8 stations

SSQ1000-BP

14 15 16 17 18 19 20 21 22 23 24 25

1 2 3 4 5 6 7 8 9 10 11 12 13

Connector terminal no.

Although the standard products come with double wiring, mixed single and double wiring is available upon request.

2-3-72

Plug Lead Unit How to Order Manifold Assembly (Example)


Example: D-sub connector kit, with cable (3 m)
2 position single (24 VDC) SQ1140-5L0-C6 (4 sets) 2 position double (Latching) (24 VDC) SQ1240-5L0-C6 (4 sets)

Series

SQ1000

Blanking plate SSQ1000-10A-4 (1 set)

3m

ti Sta

on

s1

9
Us
SS SQ 12 40 -5L SQ 1 40 -5L 24 Q1 0 L0 00 -10

ide

VQC SQ VQ0 VQ4 VQ5

0-5

A-

SQ SQ 11 11 40 -5L SQ 11 40 -5L 40

SQ 12 12 40 -5L 6

0-C 6

-C 6

SQ SQ 11 40

-5L

0-C

0-C 6

0-C

-5L

0-C 6

0-C

0-C 6

D-sub connector cable AXT100-DS25-030 Cylinder port fitting C6: One-touch fitting for 6
Ds ide

VQZ VQD

Manifold base (9 stations) SS5Q14-09FD2-D F kit (D-sub connector kit)

S S5Q14-09FD2-D 1 set (F kit 9 station manifold base) SQ1140-5L0-C6 4 sets (2 position single) SQ1240-5L0-C6 4 sets (2 position double [latching]) SSQ1000-10A-4 1 set (Blanking plate)
The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc. Add the valve and option part numbers in order starting from the first station on the D side. When entry of part numbers becomes complicated, indicate on the manifold specification sheet.

2-3-73

Series
Model

SQ1000
(2)

Valve Specifications
Flow oharacteristics Series Number of solenoids Single 2 position Model Metal seal Rubber seal Metal seal 1 4/2 (P C [dm3/(sbar)] b A/B) Cv 0.14 0.19 0.14 0.19 0.14 0.19 0.14 0.15 0.14 0.15 0.14 0.19 0.15 4/2 5/3 (A/B C [dm3/(sbar)] b 0.63 0.80 0.63 0.80 0.63 0.80 0.63 0.58 0.60 0.80 0.63 0.59 0.59 0.11 0.20 0.11 0.20 0.11 0.20 0.11 0.26 0.14 0.20 0.14 0.20 0.28 R1/R2) Cv 0.14 0.19 0.14 0.19 0.14 0.19 0.14 0.16 0.14 0.19 0.14 0.14 0.15 Response time (ms) Standard: 1W 12 or less 15 or less 15 or less 20 or less 10 or less 15 or less 20 or less 25 or less 20 or less 25 or less 20 or less 25 or less 25 or less

Low wattage 15 or less 20 or less 13 or less 20 or less 26 or less 33 or less 26 or less 33 or less 26 or less 33 or less 33 or less

Weight (g) 80 80 80 80 95 95 100 100 100 100 100 100 95

SQ1140 SQ1141 SQ1240 SQ1241 SQ1240D SQ1241D SQ1340 SQ1341 SQ1440 SQ1441 SQ1540 SQ1541 SQ1 41
A B C

0.62 0.79 0.62 0.79 0.62 0.79 0.58 0.64 0.58 0.64 0.62 0.79 0.59

0.10 0.20 0.10 0.20 0.10 0.20 0.12 0.20 0.12 0.20 0.12 0.21 0.28

Double (Latching) Rubber seal Double Metal seal (Double solenoid) Rubber seal Closed center Metal seal Rubber seal Metal seal Rubber seal Metal seal Rubber seal Rubber seal

SQ1000
3 position 4 position

Exhaust center Pressure center Dual 3 port valve

Note 1) Values for the cylinder port size of C6. Note 2) Based on JIS B 8375-1981. (Values with a supply pressure of 0.5 MPa and light/surge voltage suppressor. Values fluctuate depending on the pressure and air quality.)

Specifications
Valve construction Fluid Maximum operating pressure Min. operating pressure Single Double (Latching) Double (Double solenoid) 3 position 4 position Valve specifications 0.1 MPa 0.18 MPa 0.1 MPa 0.1 MPa 10 to 50C
(1)

Metal seal Air/Inert gas

Rubber seal
(3)

0.7 MPa (High pressure type: 1.0 MPa) 0.15 MPa 0.18 MPa 0.1 MPa 0.2 MPa 0.15 MPa Not required Push type/Locking type (Tool required) 30/150 m/s 2 Dust tight 12 VDC, 24 VDC 10% of rated voltage Equivalent to class B 1 W DC (42 mA), 0.5 W DC (21 mA) (4) 1 W DC (83 mA), 0.5 W DC (42 mA) (4)

JIS Symbol
2 position single
(A) (B) 42

Ambient and fluid temperature Lubrication Pilot valve manual override Vibration/Impact resistance (2) Protection structure Coil rated voltage Allowable voltage fluctuation Coil insulation type Power consumption (Current) 24 VDC 12 VDC

513 (R1)(P)(R2)

2 position double (Latching)


(A) (B) 42 (A) (B) 42

513 (R1)(P)(R2)

513 (R1)(P)(R2)

Metal seal
(A) (B) 42

Rubber seal
(A) (B) 42

2 position double (Double solenoid)

513 (R1)(P)(R2)

513 (R1)(P)(R2)

Metal seal

Rubber seal

3 position closed center


(A) (B) 42

Solenoid specifications

Note 1) Use dry air to prevent condensation when operating at low temperatures. Note 2) Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 2000 Hz. Test was performed at both energized and de-energized states in the axial direction and at the right angles to the main valve and armature. (Values at the initial period) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and deenergized states every once for each condition. (Values at the initial period) Note 3) Metal seal type only. [Except double (latching) type.] Note 4) Values for the low wattage (0.5 W) specification.

3 position pressure center


(A) (B) 42

4 position dual 3 port valve (B)


4 2

51 3 (R1)(P)(R2)

5 51 3 (R1)(P)(R2)

3 1

N.O.

N.O.

3 position exhaust center


(A) (B) 4 2

4 position dual 3 port valve (A)


4 2

4 position dual 3 port valve (C)


4 2

5 51 3 (R1)(P)(R2) 1

5 1

N.C.

N.C.

N.C.

N.O.

2-3-74

Plug Lead Unit Manifold Specifications


Porting specifications Base model 1(P), 3(R) Port size (1) 4(A), 2(B)
Port location

Series

SQ1000
(4) (4)

Applicable solenoid valve

Type of connection

Applicable 5 station weight stations (g)

(3)

1 station weight (g)

Port size C3 (For 3.2) C4 (For 4) C6 (For 6) M5 (M5 thread) L3 (For 3.2) L4 (For 4) L6 (For 6) L5 (M5 thread) SQ140 SQ141 F kit: D-sub connector P kit: Flat ribbon cable J kit: Flat ribbon cable PC Wiring System compatible C kit: Connector kit 26P 20P 1 to 12 stations 1 to 12 stations 1 to 9 stations 1 to 8 stations 1 to 12 stations 420 420 20 20

C8 (For 8)

Side

VQC SQ VQ0

SS5Q14-

Option Built-in silencer, direct exhaust

Top

(2)

420 460

20 35

Note 1) One-touch fittings in inch sizes are also available. For details, refer to page 2-3-110. Note 2) Can be changed to side ported configuration. Note 3) An optional specification for special wiring is available to increase the maximum number of stations. Refer to page 2-3-108 for details. Note 4) Except valves. For valve weight, refer to page 2-3-104.

VQ4 VQ5 VQZ

26P/20P (P kit) 20P (J kit)

VQD

4(A), 2(B) port 3(R) port 1(P) port 25P

F kit

P kit J kit

C kit

2-3-75

Series

SQ1000

Kit (D-sub connector kit)

Simplification and labor savings for wiring work can be achieved by using a D-sub connector for the electrical connection. Using connector for flat ribbon cable (25P) conforming to MIL standard permits the use of connectors put on the market and gives a wide interchangeability. Top or side entry for the connector can be changed freely, allowing later changes according to the mounting space.

Manifold Specifications
Series Port location Porting specifications Port size 1(P) , 3(R) 4(A) , 2(B) C8 Maximum number of stations

SQ1000

Side, Top

12 stations C3, C4, C6, M5 (24 as an option)

D-sub connector (25 pins)


Us ide

Cable assembly

AXT100-DS25- 030 050


D-sub connector cable assemblies can be ordered with manifolds. Refer to manifold ordering.
D e sid

015

12

sta

tion

D-sub Connector Cable Assembly Terminal No.


Terminal Lead wire Number color 1 Black 2 Brown Red 3 Seal (length indication) 4 Orange 015 5 Yellow Pink 6 Molded cover Blue 7 2-M2.6 x 0.45 8 Purple SMC 9 Gray Connector 10 White DB-25SF-N manufactured by 11 White Japan Aviation 55 Electronics Industry, Ltd. 12 Yellow Socket side 13 Orange 1425 14 Yellow Terminal no. 15 Pink 16 Blue 113 17 Purple 47.04 18 Gray 19 Orange 20 Red 21 Brown D-sub Connector Cable Assembly (Option) 22 Pink 23 Gray Cable Assembly part no. Note length (L) 24 Black 1.5 m AXT100-DS25-015 25 White Cable 3m AXT100-DS25-030 0.3 mm2 x 25 cores 5m AXT100-DS25-050 44 8 (2.4) 16 Cable 0.3 mm2 x 25 cores O.D. 1.4 10 Dot marking None None None None None None None White Black Black Red Red Red Black Black White None None Black White White Red Red White None

Valves are numbered from the D side.

Electrical wiring specifications D-sub connector


As the standard electrical wiring specifications, double wiring (connected to SOL. A and SOL. B) is adopted for the internal wiring of each station for 12 stations or less, regardless of valve and option types. Mixed single and double wiring is available as an option. For details, refer to page 2-3-108.

14 15 16 17 18 19 20 21 22 23 24 25

1 2 3 4 5 6 7 8 9 10 11 12 13

Connector terminal no.

Lead wire colors for D-sub connector assembly 015 AXT100-DS25- 030
050

Terminal no. Polarity 1 station 2 stations 3 stations 4 stations 5 stations 6 stations 7 stations 8 stations 9 stations 10 stations 11 stations 12 stations SOL.A SOL.B 1 14 SOL.A 2 SOL.B 15 SOL.A 3 SOL.B 16 SOL.A 4 SOL.B 17 SOL.A 5 SOL.B 18 SOL.A 6 SOL.B 19 SOL.A 7 SOL.B 20 SOL.A 8 SOL.B 21 SOL.A 9 SOL.B 22 SOL.A 10 SOL.B 23 SOL.A 11 SOL.B 24 SOL.A 12 SOL.B 25 COM. 13 () () () () () () () () () () () () () () () () () () () () () () () () (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) ()

Lead wire color Black Yellow Brown Pink Red Blue Orange Purple Yellow Gray Pink Orange Blue Red Purple Brown Gray Pink White Gray White Black Yellow White Orange
Note)

Dot marking None Black None Black None White None None None None None Black None White White White Black Red Black Red Red White Red None Red

For other commercial connectors, use a 25 pins type with female connector conforming to MIL-C-24308. Cannot be used for transfer wiring.

Electric characteristics
Item Characteristics Conductor resistance 65 or less /km, 20C Voltage limit VAC, 1 min. Insulation resistance M/km, 20C 1000 5 or less

Connector manufacturers example


Fujitsu, Ltd. Japan Aviation Electronics Industry, Ltd. J.S.T. Mfg. Co., Ltd. Hirose Electric Co., Ltd.

Note) The minimum bending radius for D-sub connector cables is 20 mm.

Positive common Negative common specifications specifications

Note) When using the negative common specifications, use valves for negative common.

2-3-76

Plug Lead Unit

Series

SQ1000

L3 5.25 37 30 M5: External pilot port 25 41.5 27 L2 L1 P = 11.5 24 Indicator light Manual override 11

VQC SQ

107.5 (3 position) 98.5 [Double (Double solenoid), Dual 3 port valve]

VQ0
94 [Single, Double (Latching)] 68 47 34

VQ4
5.5
B A B A B A
B
1.TURN 2.PUSH

(94)

35 2-M4 clamp screw EXH outlet D side


Stations 1 2 3 4 5 6 7 8 n

10

Applicable connector: D-sub connector (25P) (Conforming to MIL-C-24308) U side

49.5

Release for switching connector direction

13 28

C8: 3(R) port C8: SUP port

For top ported

(49.5) 29.5 13

7.5

27 41.5 P = 11.5 2n-C3, C4, C6, M5 (4(A), 2(B) port) C3: One-touch fitting for 3.2 C4: One-touch fitting for 4 C6: One-touch fitting for 6 M5: M5 thread

Dimensions
L L1 L2 L3 n 11 10 9 8 7 6 5 4 3 2 1 88.5 100 111.5 123 134.5 146 157.5 169 180.5 65.5 77 125 137.5 150 162.5 175 187.5 200 212.5 225 237.5 237.5 135.5 148 160.5 173 185.5 198 210.5 223 235.5 248 248 12 192 250 260.5 13 203.5 262.5 273 14 215 275 285.5

Formula: L1 = 11.5n + 54 15 226.5 287.5 298 16 238 300 310.5

n: Stations (Maximum 24 stations) 24 23 22 21 295.5 307 318.5 330 362.5 375 375 387.5 373 385.5 385.5 398

20 19 18 17 249.5 261 272.5 284 312.5 325 337.5 350 323 335.5 348 360.5

26 37

2-3-77

60

1.TURN

2.PUSH

VQ5 VQZ VQD

Series

SQ1000

Kit (Flat ribbon cable connector)

Simplification and labor savings for wiring work can be achieved by using a MIL type for the electrical connection. Using connector for flat ribbon cable (26P, 20P) conforming to MIL standard permits the use of connectors put on the market and gives a wide interchangeability. Top or side entry for the connector can be changed freely, allowing later changes according to the mounting space.

Manifold Specifications
Series Port location Side, Top Porting specifications Port size 1(P), 3(R) 4(A), 2(B) C8 Maximum number of stations

SQ1000

12 stations C3, C4, C6, M5 (24 as an option)


ide Us

Flat ribbon cable (26 pins, 20 pins)


Cable assembly

AXT100-FC 20 26

1 2 3
D e sid

12

st

atio

ns

Type 26P flat ribbon cable connector assemblies can be ordered with manifolds. Refer to manifold ordering.
Terminal no. Red
2 1

Valves are numbered from the D side.

28AWG

Electrical wiring specifications Flat ribbon cable connector


26 24 22 20 18 16 14 12 10 8 6 4 2 25 23 21 19 17 15 13 11 9 7 5 3 1

Double wiring (connected to SOL. A and SOL. B) is adopted for the internal wiring of each station, regardless of valve and option types. Mixed single and double wiring is available as an option. For details, refer to page 2-3-108.

30 (20P) 37.5 (26P)


26

25

(15.6) L

Connector terminal no. Triangle mark indicator position

Flat Ribbon Cable Connector Assembly (Option)


Assembly part no. 20P 26P 1.5 m AXT100-FC20-1 AXT100-FC26-1 3m AXT100-FC20-2 AXT100-FC26-2 5m AXT100-FC20-3 AXT100-FC26-3 For other commercial connectors, use a 26 pins or 20 pins with strain relief conforming to MIL-C-83503. Cannot be used for transfer wiring. Cable length (L)

<26P>
Terminal no. Polarity 1 station 2 stations 3 stations 4 stations 5 stations 6 stations 7 stations 8 stations 9 stations 10 stations 11 stations 12 stations SOL.A SOL.B SOL.A SOL.B SOL.A SOL.B SOL.A SOL.B SOL.A SOL.B SOL.A SOL.B SOL.A SOL.B SOL.A SOL.B SOL.A SOL.B SOL.A SOL.B SOL.A SOL.B SOL.A SOL.B 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 () () () () () () () () () () () () () () () () () () () () () () () () (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) () ()
Note)

<20P>
Terminal no. Polarity 1 station 2 stations 3 stations 4 stations 5 stations 6 stations 7 stations 8 stations 9 stations SOL.A SOL.B SOL.A SOL.B SOL.A SOL.B SOL.A SOL.B SOL.A SOL.B SOL.A SOL.B SOL.A SOL.B SOL.A SOL.B SOL.A SOL.B 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 () () () () () () () () () () () () () () () () () () (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) () ()
Note)

Connector manufacturers example


Hirose Electric Co., Ltd. Sumitomo 3M Limited Fujitsu Limited Japan Aviation Electronics Industry, Ltd. J.S.T. Mfg. Co., Ltd. Oki Electric Cable Co,. Ltd.

COM. 19 COM. 20

Positive Negative common common specifications specifications

COM. 25 COM. 26

Positive Negative common common specifications specifications

Note) When using the negative common specifications, use valves for negative common.

2-3-78

Plug Lead Unit

Series

SQ1000

5.25 45.5 37 25 41.5 27

L3 L2 L1 P=11.5 24 Indicator light Manual override

M5: External pilot port

VQC SQ VQ0 VQ4

11

98.5 [Double (Double solenoid), Dual 3 port valve] 94 [Single, Double (Latching)] 68 47 34

107.5 (3 position)

(94)

5.5

35

2-M4 clamp screw 10

Applicable connector: Flat ribbon cable connector (26P) (Conforming to MIL-C-83503)

49.5

EXH outlet

Triangle mark indicator position Release for switching connector direction D side C8: 3(R) port C8: SUP port For top ported
Stations 1 2 3 4 5 6 7 8 n

U side 9

(49.5) 29.5 13

27 41.5

7.5

P = 11.5

2n-C3, C4, C6, M5 (4(A), 2(B) port) C3: One-touch fitting for 3.2 C4: One-touch fitting for 4 C6: One-touch fitting for 6 M5: M5 thread

Dimensions
L L1 L2 L3 n 12 11 10 9 8 7 6 5 4 3 2 1 88.5 100 111.5 123 134.5 146 157.5 169 180.5 192 65.5 77 125 137.5 150 162.5 175 187.5 200 212.5 225 237.5 237.5 250 135.5 148 160.5 173 185.5 198 210.5 223 235.5 248 248 260.5

Formula: L1 = 11.5n + 54

n: Stations (Maximum 24 stations)

24 23 22 21 20 19 18 17 16 15 14 13 203.5 215 226.5 238 249.5 261 272.5 284 295.5 307 318.5 330 262.5 275 287.5 300 312.5 325 337.5 350 362.5 375 375 387.5 273 285.5 298 310.5 323 335.5 348 360.5 373 385.5 385.5 398

26 37

60

13 28

B A

B A

B A

1.TURN

2.PUSH

1.TURN

2.PUSH

VQ5 VQZ VQD

2-3-79

Series

SQ1000

Kit (PC wiring system compatible flat ribbon cable kit)

PC Wiring System compatible. Using connector for flat ribbon cable (20P) conforming to MIL standard permits the use of connectors put on the market and gives a wide interchangeability. Top or side entry for the connector can be changed freely, allowing later changes according to the mounting space.
ide

Manifold Specifications
Series Port location Side, Top Porting specifications Port size 1(P), 3(R) 4(A), 2(B) C8 Maximum number of stations

SQ1000

8 stations C3, C4, C6, M5 (16 as an option)

Us

Ds

ide

12

t s

atio

ns

Valves are numbered from the D side.

Electrical wiring specifications


Double wiring (connected to SOL. A and SOL. B) is adopted for the internal wiring of each station, regardless of valve and option types. Mixed single and double wiring is available as an option. For details, refer to page 2-3-108.

Terminal no. Polarity

Flat ribbon cable connector


1 station
20 18 16 14 12 10 8 6 4 2 19 17 15 13 11 9 7 5 3 1

SOL.A 20 SOL.B 18 SOL.A 16 SOL.B 14 SOL.A 12 SOL.B 10 SOL.A 8 6 SOL.B

() () () () () () () () () () () () () () () () () () (+) (+)

(+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) () ()

2 stations

3 stations

4 stations Connector terminal no. 5 stations

SOL.A 19 SOL.B 17 SOL.A 15 SOL.B 13 SOL.A 11 SOL.B 9 SOL.A 7 5 4 3 COM. COM. 2 1 SOL.B

Triangle mark indicator position

6 stations

7 stations

8 stations

Note) Positive Negative common common specifications specifications

Note) When using the negative common specifications, use valves for negative common. For details about the PC Wiring System, refer to catalog CAT.ES02-20 separately.

2-3-80

Plug Lead Unit

Series

SQ1000

5.25 45.5 37 25 41.5 27

L3 L2 L1 P = 11.5 24 Indicator light Manual override

M5: External pilot port

11

VQC
98.5 [Double (Double solenoid), Dual 3 port valve] 94 [Single, Double (Latching)] 68 47 34

SQ VQ0
5.5
B A B A B A
B
1.TURN 2.PUSH

107.5 (3 position)

(94)

35

13

28

10

49.5 Applicable connector: Flat ribbon cable connector (20P) (Conforming to MIL-C-83503)

Triangle mark indicator position Release for switching connector direction

EXH outlet

D side C8: 3(R) port C8: SUP port

Stations

For top ported

(49.5) 29.5 13

27 41.5

7.5

P = 11.5

2n-C3, C4, C6, M5 (4(A), 2(B) port) C3: One-touch fitting for 3.2 C4: One-touch fitting for 4 C6: One-touch fitting for 6 M5: M5 thread

Dimensions
L L1 L2 L3 n

Formula: L1 = 11.5n + 54

n: Stations (Maximum 16 stations) 15 226.5 287.5 298 16 238 300 310.5

9 8 7 6 5 4 3 2 1 88.5 100 111.5 123 134.5 146 157.5 65.5 77 125 137.5 150 162.5 175 187.5 200 212.5 225 135.5 148 160.5 173 185.5 198 210.5 223 235.5

14 13 12 11 10 169 180.5 192 203.5 215 237.5 237.5 250 262.5 275 248 248 260.5 273 285.5

26 37

60

1.TURN

2.PUSH

VQ4 VQ5 VQZ VQD

2-M4 clamp screw

U side

2-3-81

Series

SQ1000

Kit (Connector)

Standard with lead wires connected to each valve individually.

Manifold Specifications
Series Port location Side, Top Porting specifications Port size 1(P), 3(R) 4(A), 2(B) C8 C3, C4, C6, M5 Maximum number of stations 24 stations
Ds ide

SQ1000

Ds

ide

12

st

atio

ns

Valves are numbered from the D side.

Wiring Specifications: Positive COM Specifications


Since lead wires are connected to the valves as shown below, connect each wire to the power supply. Single solenoid
Lead wire color SOL.A () Black

Wiring Specifications: Negative COM Specifications (Option)


Since lead wires are connected to the valves as shown below, connect each wire to the power supply. Single solenoid
SOL.A Lead wire color Red COM. () Black (+) Red: A side solenoid (+) Black: COM ()

COM. (+) Red Black: A side solenoid () Red: COM (+)

Double solenoid
SOL.A ()

Lead wire color Black COM. (+) Red White () Black: A side solenoid () Red: COM (+) White: B side solenoid ()

Double solenoid
Lead wire color Red COM.() Black SOL.B White (+) SOL.A (+) Red: A side solenoid (+) Black: COM () White: B side solenoid (+) Plug connector lead wire length The lead wire length of the valves with lead wire is 300 mm. When ordering a lead wire length of 600 mm or longer, list the part numbers for the valve without connector and the connector assembly. Example) For lead wire length of 1000 mm: SQ1140-5LO-C63 pcs. AXT661-14ANL-103 pcs.

SOL.B

Plug connector lead wire length The lead wire length of the valves with lead wire is 300 mm. When ordering a lead wire length of 600 mm or longer, list the part numbers for the valve without connector and the connector assembly. Example) For lead wire length of 1000 mm: SQ1140-5LO-C63 pcs. AXT661-14AL-103 pcs.

Connector Assembly Part No.


Lead wire length Socket only (3 pcs.) 300 mm 600 mm 1000 mm 2000 mm 3000 mm AXT661-14AL AXT661-14AL-6 AXT661-14AL-10 AXT661-14AL-20 AXT661-14AL-30 Single solenoid Double solenoid AXT661-13AL AXT661-13AL-6 AXT661-13AL-10 AXT661-13AL-20 AXT661-13AL-30 AXT661-12AL

Connector Assembly Part no.


Lead wire length Socket only (3 pcs.) 300 mm 600 mm 1000 mm 2000 mm 3000 mm AXT661-14ANL AXT661-14ANL-6 AXT661-14ANL-10 AXT661-14ANL-20 AXT661-14ANL-30 Single solenoid Double solenoid AXT661-13ANL AXT661-13ANL-6 AXT661-13ANL-10 AXT661-13ANL-20 AXT661-13ANL-30 AXT661-12AL

Note) When using the negative common specifications, use valves for negative common.

2-3-82

Plug Lead Unit

Series

SQ1000

L3 5.25 41.5 27 M5: External pilot port L2 L1 Lead wire length: 300 9.5 P=11.5 24 Indicator light Manual override

VQC SQ

98.5 [Double (Double solenoid), Dual 3 port valve]

94 [Single, Double (Latching)] 68

VQ0 VQ4
5.5
B A B A
6

107.5 (3 position)

(94)

47

34

35

2-M4 clamp screw 10

49.5

EXH outlet

C8: SUP port

For top ported

(49.5) 29.5 13

7.5

27 41.5 P = 11.5 2n-C3, C4, C6, M5 (4(A), 2(B) port) C3: One-touch fitting for 3.2 C4: One-touch fitting for 4 C6: One-touch fitting for 6 M5: M5 thread

Dimensions
L L1 L2 L3 n 11 10 9 8 7 6 5 4 3 2 1 88.5 100 111.5 123 134.5 146 157.5 169 180.5 65.5 77 87.5 100 112.5 125 137.5 150 162.5 175 175 187.5 200 110.5 123 135.5 148 160.5 173 185.5 185.5 198 210.5 98 12 192 212.5 223 13 203.5 225 235.5

Formula: L1 = 11.5n + 54 17 16 15 14 215 226.5 238 249.5 237.5 250 262.5 275 248 260.5 273 285.5 18 261 287.5 298

n: Stations (Maximum 24 stations) 23 22 21 20 284 295.5 307 318.5 312.5 325 337.5 350 323 335.5 348 360.5 24 330 350 360.5

19 272.5 300 310.5

26 37

60

C8: 3(R) port

D side

Stations

U side

13 28

B A

1.TURN

2.PUSH

1.TURN

2.PUSH

VQ5 VQZ VQD

2-3-83

Series SQ2000

Plug Lead Unit


How to Order Manifold

SS5Q24

08 FD2

D
Option
Nil None

Stations
01
1 station
Note)

16

16 stations

Note) The maximum number of stations depends on the type of electrical entries.

02 to 24(1) DIN rail length specified B Back pressure check valve K (2) Special wiring specifications (Except double wiring) N With name plate (Side ported only) R External pilot specifications S Built-in silencer, direct exhaust
Note 1) Specify DIN rail length with D at the end. (Enter the number of stations inside .) Example: -D08 Note 2) Standard wiring specifications are for double wiring. Indicate wiring specifications for single wiring or mixed single and double wiring, or when exceeding the standard number of stations. (Except C kit) Note 3) When two or more symbols are specified, indicate them alphabetically. Example: -BKN

Manifold mounting
D Note) E
DIN rail mounting style Direct mounting style

Note) Type E is only available with a C kit.

Electrical entry
Kit type U side D side D-sub connector kit Lead wire connector location Cable specifications D-sub connector (25P) kit, without cable D-sub connector (25P) kit, with 1.5 m cable D side D-sub connector (25P) kit, with 3.0 m cable D-sub connector (25P) kit, with 5.0 m cable Flat ribbon cable (26P) kit, without cable D side
(1)

Stations

Max. number (2) of stations for Max. number of special wiring solenoids specifications

F kit

P kit

Flat ribbon cable connector kit

( 26P ) 20P

FD0 FD1 FD2 FD3 PD0 PD1 PD2 PD3 PDC

1 to 12 stations

16 stations

24

Flat ribbon cable (26P) kit, with 1.5 m cable Flat ribbon cable (26P) kit, with 3.0 m cable Flat ribbon cable (26P) kit, with 5.0 m cable Flat ribbon cable (20P) kit, without cable

1 to 12 stations

16 stations

24

1 to 9 stations

18

J kit
JD0
Flat ribbon cable (20P) (PC Wiring System compatible) D side Flat ribbon cable (20P) PC Wiring System compatible 1 to 8 stations 16 stations 16

C kit
C
Connector kit
Note 1) Separately order the 20P type cable assembly for the P kit. Note 2) The maximum number of stations should not be more than the maximum number of solenoids. (The number of solenoids are counted as: 1 for single solenoids and 2 for type 3P and 4P double solenoids.)

Connector kit

1 to 16 stations

2-3-84

Plug Lead Unit

Series

SQ2000

How to Order Valves

SQ2 1 4 0
Type of actuation
2 position single
(A) (B) 42 5 13 (R1) (P)(R2)

5 L

C6
With/Without manifold block
Nil Without manifold block M With manifold block MB With manifold block, built-in back pressure check valve

2 position double (Latching)


(A)(B) 42 5 13 (R1) (P)(R2) (A)(B) 42 513 (R1) (P)(R2)

VQC SQ
Lead wire is not included. Lead wire is not included. When ordering with manifolds When only valves are required. For adding stations

Metal seal
(A)(B) 42 5 13 (R1) (P)(R2)

Rubber seal
(A)(B) 42 5 13 (R1) (P)(R2)

2 position double (Double solenoid) (1)

VQ0 VQ4 VQ5 VQZ

Metal seal

Rubber seal
(A) (B) 42 513 (R1) (P)(R2)

3 position closed center

3 position exhaust center

(A) (B) 42 51 3 (R1) (P)(R2)

Port plug mounting port


Nil None Port 4(A) Port 2(B)

VQD

3 position pressure center

(A)(B) 42 513 (R1) (P)(R2)

A B

Cylinder port
C4 C6 C8 L4 L6 L8
One-touch fitting for 4 One-touch fitting for 6 One-touch fitting for 8 One-touch fitting for 4 One-touch fitting for 6 One-touch fitting for 8 Side ported
Note)

4 position dual 3 port valve


(2)
(A) 4 (B) 2

A
5 (R1)

N.C. (2)
(A) 4 5 (R1)

1 (P)

3 (R2)

N.C.
(B) 2 3 (R2)

4 position dual 3 port valve

B
N.O. (2)
(A) 4 5 (R1) 1 (P)

Top ported

N.O.
(B) 2 3 (R2)

Note) Can be changed to side ported configuration.

4 position dual 3 port valve

Manual override
Nil

C
N.C.
1 (P)

B Note)
Locking type (Tool required)

D Note)
Slide locking type (Manual type)
Only side ported type applicable

N.O.

Non-locking push type (Tool required)

Note 1) For double solenoid specifications, the function symbol below is D. Note 2) Only rubber seal types are applicable.

Seal
0 1
Metal seal Rubber seal

Function
Nil Standard type (1.0 W DC)

Note) Except double (latching) type.

D 2 position double (Double solenoid specifications) Negative common N Y (1) Low wattage type (0.5 W DC) External pilot specifications R(2)
Note 1) Except double (latching) type. Note 2) Except dual 3 port valves. Note 3) When two or more symbols are specified, indicate them alphabetically.

Electrical entry
L
Plug connector type With 300 mm lead wire

LO
Plug connector type without connector

Coil voltage
5 6
24 VDC 12 VDC
Note) Light/Surge voltage suppressor is built-in. For F, P, J kit manifolds Note) Note) Indicate LO when ordering centralized wiring type manifolds, F, P, and J kits, since the lead wire will be attached to the manifold side.

2-3-85

Series

SQ2000
P. 2-3-103 Individual SUP/EXH spacer P. 2-3-104 Name plate (-N) P. 2-3-106 External pilot P. 2-3-107

Manifold Option
Blanking plate

SSQ2000-10A-4

SSQ2000-PR1-4-C8 L8

SSQ2000-N3-n

specifications (-R)
External pilot port

SUP/EXH block

P. 2-3-103 SUP block plate

P. 2-3-105 Blanking plug

P. 2-3-106 Dual flow fitting

P. 2-3-107

SSQ2000-PR-3-C10 (-S)

SSQ2000-B-R
R P

KQ2P-04/06/08/10

SSQ2000-52A-C10 N11

D side

U side

Individual SUP spacer P. 2-3-103 EXH block plate

P. 2-3-105 Port plug

P. 2-3-106 Silencer

P. 2-3-107

SSQ2000-P-4-C8 L8

SSQ2000-B-R
R P

VVQZ2000-CP

(For EXH port)

D side
SM C

AN

20

U side

Individual EXH spacer P. 2-3-104 Back pressure check valve (-B) SSQ2000-R-4-C8
L8

P. 2-3-105 Built-in silencer (-S) P. 2-3-106 Special wiring

P. 2-3-108
Terminal no.

specifications (-K)
D-sub connector
1 station 2 stations 3 stations 4 stations 5 stations 6 stations 7 stations 8 stations
SOL.A SOL.A SOL.A SOL.A SOL.A SOL.B SOL.A SOL.B SOL.A SOL.B SOL.A SOL.B COM. 1 14 2 15 3 16 4 17 5 18 6 19 () () () () () () () () () () () ()

SSQ2000-BP

14 15 16 17 18 19 20 21 22 23 24 25

1 2 3 4 5 6 7 8 9 10 11 12 13

13 (+)

Connector terminal no. Although the standard products come with double wiring, mixed single and double wiring is available upon request.

2-3-86

Plug Lead Unit How to Order Manifold Assembly (Example)


Example: D-sub connector kit, with cable (3 m)
2 position single (24 VDC) SQ2140-5L0-C8 (3 sets) 2 position double (Double solenoid) (24 VDC) SQ2240D-5L0-C8 (3 sets)
8
Us
SS
SQ 0-1 23 0A 40 -4 -5L 0-C D-5 8 L0 40 SQ -C8 D-5 22 L0 40 SQ -C8 D-5 21 L0 40 SQ -C8 -5L 21 0-C 40 SQ -5L 8 21 0-C 40 -5L 8 0-C 8

Series

SQ2000

3 position exhaust center (24 VDC) SQ2340-5L0-C8 (1 set) Blanking plate SSQ2000-10A-4 (1 set)

3m

1 Sta n tio s

ide

VQC SQ VQ0 VQ4 VQ5

Q2

00

SQ

SQ

22

22

40

D-sub connector cable AXT100-DS25-030


Ds ide

Cylinder port fitting C8: 8 One-touch fitting Manifold base (8 stations) SS5Q24-08FD2-D

VQZ VQD

F kit (D-sub connector kit)

SS5Q24-08FD2-D 1 set (F kit 8 station manifold base) SQ2140-5L0-C8 3 sets (2 position single) SQ2240D-5L0-C8 3 sets (2 position double [double solenoid]) SQ2340-5L0-C8 1 set (3 position exhaust center) SSQ2000-10A-4 1 set (Blanking plate)
The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc. Add the valve and option part numbers in order starting from the first station on the D side. When entry of part numbers becomes complicated, indicate on the manifold specification sheet.

2-3-87

Series

SQ2000
(2)

Valve Specifications
Model
Series Number of solenoids Flow characteristics Model Metal seal Rubber seal Metal seal 1 C [dm3/(sbar)] Single 2 position 4/2 (P b 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 A/B) Cv 0.51 0.51 0.51 0.51 0.51 0.51 0.46 0.46 0.46 0.46 0.51 0.56 0.40 4/2 5/3 (A/B C [dm3/(sbar)] b 2.4 3.1 2.4 3.1 2.4 3.1 2.1 1.8 2.4 3.1 2.1 1.8 1.5 0.14 0.18 0.14 0.18 0.14 0.18 0.15 0.29 0.14 0.14 0.18 0.30 0.17 R1/R2) Cv 0.57 0.71 0.57 0.71 0.57 0.71 0.47 0.45 0.55 0.58 0.47 0.47 0.40 Response time (ms) Standard: 1W Low wattage Weight (g) 145 140 145 140 160 155 180 175 180 175 180 175 155

SQ2140 SQ2141 SQ2240 SQ2241 SQ2240D SQ2241D SQ2340 SQ2341 SQ2440 SQ2441 SQ2540 SQ2541 SQ2 41
A B C

2.2 2.3 2.2 2.3 2.2 2.3 1.9 1.9 1.9 1.9 2.3 2.5 1.5

20 or less 26 or less 24 or less 31 or less 26 or less 31 or less

Double (Latching) Rubber seal Double Metal seal (Double solenoid) Rubber seal Closed center Exhaust center Pressure center Metal seal Rubber seal Metal seal Rubber seal Metal seal Rubber seal Rubber seal

15 or less 20 or less 20 or less 26 or less 34 or less 44 or less 34 or less 44 or less 34 or less 44 or less 34 or less 44 or less 34 or less 44 or less 34 or less 44 or less 34 or less 44 or less

SQ2000
3 position 4 position

Dual 3 port valve

Note 1) Values for the top ported cylinder port size of C8. The side ported type will be about 10% less. Note 2) Based on JIS B 8375-1981. (Values with a supply pressure of 0.5 MPa and light/surge voltage suppressor. Values fluctuate depending on the pressure and air quality.)

Specifications
Valve construction Fluid Maximum operating pressure Min. operating pressure Single Double (Latching) Double (Double solenoid) 3 position 4 position 0.1 MPa 0.18 MPa 0.1 MPa 0.1 MPa 10 to 50C (1) Not required
Push type (Tool required)/Locking type (Tool required) Slide locking type (Manual type)

Metal seal Air/Inert gas 0.7 MPa

Rubber seal

0.15 MPa 0.18 MPa 0.1 MPa 0.2 MPa 0.15 MPa

Valve specifications

JIS Symbol
2 position single
(A) (B) 42

Ambient and fluid temperature Lubrication Pilot valve manual override Vibration/Impact resistance (2) Protection structure Coil rated voltage Allowable voltage fluctuation Coil insulation type Power consumption (Current) 24 VDC 12 VDC

30/150 m/s 2 Dust tight 12 VDC, 24 VDC 10% of rated voltage Equivalent to class B 1 W DC (42 mA), 0.5 W DC (21 mA) (3) 1 W DC (83 mA), 0.5 W DC (42 mA) (3)

513 (R1)(P)(R2)

2 position double (Latching)


(A) (B) 42 (A) (B) 42

51 3 (R1)(P)(R2)

51 3 (R1)(P)(R2)

Metal seal
(A) (B) 42

Rubber seal
(A) (B) 42

2 position double (Double solenoid)

51 3 (R1)(P)(R2)

51 3 (R1)(P)(R2)

Metal seal

Rubber seal

3 position closed center


(A) (B) 42

3 position pressure center


(A) (B) 42

Solenoid specifications

Note 1) Use dry air to prevent condensation when operating at low temperatures. Note 2) Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 2000 Hz. Test was performed at both energized and de-energized states in the axial direction and at the right angles to the main valve and armature. (Values at the initial period) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and deenergized states every once for each condition. (Values at the initial period) Note 3) Values for the low wattage (0.5 W) specifications.

4 position dual 3 port valve (B)


4 5 2 3

51 3 (R1)(P) (R2)

513 (R1)(P)(R2)

N.O.

N.O.

3 position exhaust center


(A) (B) 4 2

4 position dual 3 port valve (A) 4 position dual 3 port valve (C)
4 5 2 3 1 4 5 2 3

5 13 (R1) (P) (R2)

N.C.

N.C.

N.C.

1.0

N.O.

2-3-88

Plug Lead Unit Manifold Specifications


Porting specifications Base model 1(P), 3(R) Port size
(1)

Series

SQ2000
(3) (4) (4)

4(A), 2(B)
Port location

Applicable solenoid valve

Type of connection

Applicable stations

5 station weight (g)

1 station weight (g)

Port size C4 (For 4) C6 (For 6) C8 (For 8) SQ2 SQ2 40 41 F kit: D-sub connector P kit: Flat ribbon cable J kit: Flat ribbon cable PC Wiring System compatible C kit: Connector kit 26P 20P 1 to 12 stations 1 to 12 stations 1 to 9 stations 1 to 8 stations 580 580 580 620 35 35 35 50

C10 (For 10)

Side

VQC SQ VQ0 VQ4 VQ5 VQZ VQD

SS5Q24-

Option Built-in silencer, direct exhaust

Top

(2)

L4 (For 4) L6 (For 6) L8 (For 8)

1 to 12 stations

Note 1) One-touch fittings in inch sizes are also available. For details, refer to page 2-3-110. Note 2) Can be changed to side ported configuration. Note 3) An optional specification for special wiring is available to increase the maximum number of stations. Refer to page 2-3-108 for details. Note 4) Except valves. For valve weight, refer to page 2-3-88.

26P/20P (P kit) 20P (J kit)

4(A), 2(B) port R port 1(P) port 25P

F kit

P kit J kit

C kit

2-3-89

Series

SQ2000

Kit (D-sub Connector kit)

Simplification and labor savings for wiring work can be achieved by using a D-sub connector for the electrical connection. Using connector for flat ribbon cable (25P) conforming to MIL standard permits the use of connectors put on the market and gives a wide interchangeability. Top or side entry for the connector can be changed freely, allowing later changes according to the mounting space.

Manifold specifications
Series Port location Porting specifications Port size 1(P), 3(R) 4(A), 2(B) C10 C4, C6, C8
ide

Maximum number of stations 12 stations (16 as an option)

SQ2000

Side, Top

D-sub Connector (25 pins)


Cable assembly
015 AXT100-DS25- 030 050 D-sub connector cable assemblies can be ordered with manifolds.
Ds ide

Us

D-sub Connector Cable Assembly Terminal No.


Cable 0.3 mm2 x 25 cores O.D. 1.4 10 Seal (length indication) 015 L Molded cover 44 2-M2.6 x 0.45 SMC 8 Connector DB-25SF-N manufactured by Japan Aviation Electronics Industry, Ltd. Socket side Terminal no. 113 47.04 Terminal Lead wire Dot number color marking 1 Black None 2 Brown None Red None 3 4 Orange None 5 Yellow None Pink None 6 Blue None 7 8 Purple White Gray Black 9 10 White Black 11 White Red 12 Yellow Red 13 Orange Red 14 Yellow Black 15 Pink Black 16 Blue White 17 Purple None 18 Gray None 19 Orange Black 20 Red White 21 Brown White 22 Pink Red 23 Gray Red 24 Black White 25 White None

Valves are numbered from the D side.

12

tati

ons

Electrical wiring specifications D-sub connector


As the standard electrical wiring specifications, double wiring (connected to SOL. A and SOL. B) is adopted for the internal wiring of each station for 12 stations or less, regardless of valve and option types. Mixed single and double wiring is available as an option. For details, refer to page 2-3-108.

14 15 16 17 18 19 20 21 22 23 24 25

1 2 3 4 5 6 7 8 9 10 11 12 13

Connector terminal no.

(2.4)

55 1425

Lead wire colors for D-sub connector assembly 015 AXT100-DS25- 030
050

16

Terminal no. Polarity 1 station 2 stations 3 stations 4 stations 5 stations 6 stations 7 stations 8 stations SOL.A SOL.B SOL.A SOL.B SOL.A SOL.B SOL.A SOL.B SOL.A SOL.B SOL.A SOL.B SOL.A SOL.B SOL.A SOL.B SOL.A SOL.B SOL.A SOL.B SOL.A SOL.B SOL.A SOL.B COM. 1 14 2 15 3 16 4 17 5 18 6 19 7 20 8 21 9 22 10 23 11 24 12 25 13 () () () () () () () () () () () () () () () () () () () () () () () () (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) ()

Lead wire color Black Yellow Brown Pink Red Blue Orange Purple Yellow Gray Pink Orange Blue Red Purple Brown Gray Pink White Gray White Black Yellow White Orange
Note)

Dot marking None Black None Black None White None None None None None Black None White White White Black Red Black Red Red White Red None Red

D-sub Connector Cable Assembly (Option)


Cable Assembly part no. length (L) 1.5 m 3m 5m AXT100-DS25-015 AXT100-DS25-030 AXT100-DS25-050 Note Cable 0.3 mm2 x 25 cores

For other commercial connectors, use a 25 pins type with female connector conforming to MILC-24308. Cannot be used for transfer wiring.

Electric Characteristics
Item Characteristics Conductor resistance 65 or less /km, 20C Voltage limit VAC, 1 min. 1000

Connector manufacturers example


Fujitsu, Ltd. Japan Aviation Electronics Industry, Ltd. J.S.T. Mfg. Co., Ltd. Hirose Electric Co., Ltd.

9 stations 10 stations 11 stations 12 stations

Insulation resistance 5 or less M/km, 20C


Note) The minimum bending radius for D-sub connector cables is 20 mm.

Positive common Negative common specifications specifications Note) When using the negative common specifications, use valves for negative common.

2-3-90

Plug Lead Unit

Series

SQ2000

58 33.4 18
(Mounting hole dimension)

5.25 M5: External pilot port Release for switching connector direction 147 (3 position) 12 131.5 [Single, Double, Dual 3 port valve] 122.3 70 56 10.4 35 5.5 5.4 37 29.5 25 48.7 30 1

L3 L2 L1 P = 17.5 28.8 Indicator light

VQC SQ

8.5

Manual override

VQ0 VQ4
2-M4 clamp screw

(131.5)

VQ5
A 4

VQZ
18.5 37.6 53.6

VQD

12

EXH outlet Applicable connector: D-sub connector (25P) (Conforming to MIL-C-24308) D side C10: EXH port C10: 1(P) port
R 3

Stations

For top ported

(58) 39.5 21

30 48.7

7.5

P = 17.5 2n- C4, C6, C8 (4(A), 2(B) port) C4: One-touch fitting for 4 C6: One-touch fitting for 6 C8: One-touch fitting for 8

Dimensions
L L1 L2 L3 n

Formula: L1 = 17.5n + 60

n: Stations (Maximum 16 stations)

16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 77.5 95 112.5 130 147.5 165 182.5 200 217.5 235 252.5 270 287.5 305 322.5 340 137.5 162.5 175 187.5 212.5 225 250 262.5 275 300 312.5 337.5 350 362.5 387.5 400 148 173 185.5 198 223 235.5 260.5 273 285.5 310.5 323 348 360.5 373 398 410.5

25.5 41.5

2-3-91

62

10

B 2

U side

Series

SQ2000

Kit (Flat ribbon cable connector)

Simplification and labor savings for wiring work can be achieved by using a MIL type for the electrical connection. Using connector for flat ribbon cable (26P, 20P) conforming to MIL standard permits the use of connectors put on the market and gives a wide interchangeability. Top or side entry for the connector can be changed freely, allowing later changes according to the mounting space.

Manifold Specifications
Series Port location Porting specifications Port size 1(P), 3(R) 4(A), 2(B) C10 C4, C6, C8
U sid e

Maximum number of stations 12 stations (16 as an option)

SQ2000

Side, Top

Flat Ribbon Cable (26 pins, 20 pins)


Cable assembly 1 AXT100-FC 20 - 2 26 3
Type 26P flat ribbon cable connector assemblies can be ordered with manifolds. Refer to manifold ordering.
D sid e

3 12

tati

ons

Valves are numbered from the D side.

Terminal no. Red

28AWG

Electrical wiring specifications Flat ribbon cable connector


26 24 22 20 18 16 14 12 10 8 6 4 2 25 23 21 19 17 15 13 11 9 7 5 3 1 Double wiring (connected to SOL. A and SOL. B) is adopted for the internal wiring of each station, regardless of valve and option types. Mixed single and double wiring is available as an option. For details, refer to page 2-3-108.

2 30 (20P) 37.5 (26P) 26

25

(15.6) L

Connector terminal no. Triangle mark indicator position

Flat Ribbon Cable Connector Assembly (Option)


20P 26P 1.5 m AXT100-FC20-1 AXT100-FC26-1 3m AXT100-FC20-2 AXT100-FC26-2 5m AXT100-FC20-3 AXT100-FC26-3 For other commercial connectors, use a 26 pins or 20 pins with strain relief conforming to MIL-C-83503. Cannot be used for transfer wiring. Cable length (L) Assembly part no.

<26P>
Terminal no. Polarity 1 station 2 stations 3 stations 4 stations 5 stations 6 stations 7 stations 8 stations 9 stations 10 stations 11 stations 12 stations SOL.A SOL.B SOL.A SOL.B SOL.A SOL.B SOL.A SOL.B SOL.A SOL.B SOL.A SOL.B SOL.A SOL.B SOL.A SOL.B SOL.A SOL.B SOL.A SOL.B SOL.A SOL.B SOL.A SOL.B COM. COM. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 () () () () () () () () () () () () () () () () () () () () () () () () (+) 1 station (+) (+) 2 stations (+) (+) 3 stations (+) (+) 4 stations (+) (+) 5 stations (+) (+) 6 stations (+) (+) 7 stations (+) (+) 8 stations (+) (+) 9 stations (+) (+) (+) (+) (+) (+) (+) () ()
Note)

<20P>
Terminal no. Polarity SOL.A SOL.B SOL.A SOL.B SOL.A SOL.B SOL.A SOL.B SOL.A SOL.B SOL.A SOL.B SOL.A SOL.B SOL.A SOL.B SOL.A SOL.B COM. COM. 1 () 2 () 3 () 4 () 5 () 6 () 7 () 8 () 9 () 10 () 11 () 12 () 13 () 14 () 15 () 16 () 17 () 18 () 19 (+) 20 (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) () ()
Note)

Connector manufacturers example


Hirose Electric Co., Ltd. Sumitomo 3M Limited Fujitsu Limited Japan Aviation Electronics Industry, Ltd. J.S.T. Mfg. Co., Ltd. Oki Electric Cable Co,. Ltd.

Positive Negative common common specifications specifications

25 (+) 26 (+)

Positive Negative common common specifications specifications

Note) When using the negative common specifications, use valves for negative common.

2-3-92

Plug Lead Unit

Series

SQ2000

58 33.4 18 (Mounting hole dimension) 8.5

5.25 M5: External pilot port Release for switching connector direction 147 (3 position) 12 131.5 [Single, Double, Dual 3 port valve] 122.3 70 37 25 48.7 30 1

L3 L2 L1 P = 17.5 28.8 Indicator light

Manual override

VQC SQ

10.4 5.4

5.5

2-M4 clamp screw

VQ0 VQ4

(131.5)

35

56

37.6

53.6

Triangle mark indicator position Applicable connector: Flat ribbon cable connector (26P) (Conforming to MIL-C-83503)

12

EXH outlet

D side C10: EXH port C10: 1(P) port

Stations

U side 10 25.5

For top ported

(58) 39.5 21

18.5

30 48.7

7.5

P = 17.5

2n-C3, C4, C8 (4(A), 2(B) port) C4: One-touch fitting for 4 C6: One-touch fitting for 6 C8: One-touch fitting for 8

Dimensions
L L1 L2 L3 n

Formula: L1 = 17.5n + 60

n: Stations (Maximum 16 stations)

16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 77.5 95 112.5 130 147.5 165 182.5 200 217.5 235 252.5 270 287.5 305 322.5 340 137.5 162.5 175 187.5 212.5 225 250 262.5 275 300 312.5 337.5 350 362.5 387.5 400 148 173 185.5 198 223 235.5 260.5 273 285.5 310.5 323 348 360.5 373 398 410.5

2-3-93

41.5

62

B 2

A 4

VQ5 VQZ VQD

Series

SQ2000

Kit (PC wiring system compatible flat ribbon cable Kit)

PC Wiring System compatible. Using connector for flat ribbon cable (20P) conforming to MIL standard permits the use of connectors put on the market and gives a wide interchangeability. Top or side entry for the connector can be changed freely, allowing later changes according to the mounting space.
ide

Manifold specifications
Series Port location Porting specifications Port size 1(P), 3(R) 4(A), 2(B) C10 C4, C6, C8 Maximum number of stations 8 stations (16 as an option)

SQ2000

Side, Top

Us

Ds

ide

12

t s

atio

ns

Valves are numbered from the D side.

Electrical wiring specifications


Double wiring (connected to SOL. A and SOL. B) is adopted for the internal wiring of each station, regardless of valve and option types. Mixed single and double wiring is available as an option. For details, refer to page 2-3-108.

Terminal no.
SOL.A 20 18 16 14 12 10 8 6 19 17 15 13 11 9 7 5 4 3 COM. COM. 2 1

Polarity
() () () () () () () () () () () () () () () () () () (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) (+) () ()
Negative common specifications
Note)

1 station Flat ribbon cable connector 2 stations


20 18 16 14 12 10 8 6 4 2 19 17 15 13 11 9 7 5 3 1 Triangle mark indicator position Connector terminal no.

SOL.B SOL.A SOL.B SOL.A

3 stations

SOL.B SOL.A

4 stations

SOL.B SOL.A

5 stations

SOL.B SOL.A

6 stations

SOL.B SOL.A

7 stations

SOL.B SOL.A

8 stations

SOL.B

Positive common specifications

Note) When using the negative common specifications, use valves for negative common. For details about the PC Wiring System, refer to catalog CAT.ES02-20 separately.

2-3-94

Plug Lead Unit

Series

SQ2000

M5: External pilot port Release for switching connector direction L3 L2 37 25 48.7 30 1 L1 P = 17.5 28.8 Indicator light

58 33.4 18
(Mounting hole dimension)

147 (3 position) 12 131.5 [Single, Double, Dual 3 port valve] 122.3 70 56 10.4 35 5.4 5.5

Manual override

VQC SQ

8.5

(131.5)

18.5 37.6 53.6

Triangle mark indicator position Applicable connector: Flat ribbon cable connector (20P) (Conforming to MIL-C-83503)

12

EXH outlet

D side C10: EXH port C10: SUP port

Stations

For top ported

(58) 39.5 21

30 48.7

7.5

P = 17.5 2n-C4, C6, C8 (4(A), 2(B) port) C4: One-touch fitting for 4 C6: One-touch fitting for 6 C8: One-touch fitting for 8

Dimensions
L L1 L2 L3 n

Formula: L1 = 17.5n + 60

n: Stations (Maximum 16 stations) 14 305 362.5 373 15 322.5 387.5 398 16 340 400 410.5

9 8 7 6 5 4 3 2 1 77.5 95 112.5 130 147.5 165 182.5 200 217.5 137.5 162.5 175 187.5 212.5 225 250 262.5 275 148 173 185.5 198 223 235.5 260.5 273 285.5

13 12 11 10 235 252.5 270 287.5 300 312.5 337.5 350 310.5 323 348 360.5

25.5 41.5 62

2-3-95

10

B 2

A 4

1.TURN

2.PUSH

1.TURN

2.PUSH

2-M4 clamp screw

VQ0 VQ4 VQ5 VQZ VQD

U side

Series

SQ2000

Kit (Connector)

Standard with lead wires connected to each valve individually.

Manifold Specifications
Porting specifications Series Port location Side, Top Port size 1(P), 3(R) 4(A), 2(B) C10 C4, C6, C8 Maximum number of stations 16 stations

SQ2000

Us

ide

id Ds

3 12

st

atio

ns

Valves are numbered from the D side.

Wiring Specifications: Positive COM Specifications


Since lead wires are connected to the valves as shown below, connect each wire to the power supply.

Wiring Specifications: Negative COM Specifications (Option)


Since lead wires are connected to the valves as shown below, connect each wire to the power supply.

Single solenoid
SOL.A Lead wire color () COM.(+) Black Red

Single solenoid
SOL.A Lead wire color (+) COM.() Red Black

Black: A side solenoid ()

Red: A side solenoid (+)

Red: COM (+)

Black: COM ()

Double solenoid
SOL.A () Lead wire color Black Red White Black: A side solenoid ()

Double solenoid
SOL.A Lead wire color (+) COM. () SOL.B (+) Red Black White

COM. (+) SOL.B ()

Red: A side solenoid (+)

Red: COM (+) White: B side solenoid ()

Black: COM () White: B side solenoid (+)

Plug connector lead wire length The lead wire length of the valves with lead wire is 300 mm. When ordering a lead wire length of 600 mm or longer, list the part numbers for the valve without connector and the connector assembly. Example) For lead wire length of 1000 mm: SQ1140-5LO-C63 pcs. AXT661-14AL-103 pcs.

Plug connector lead wire length The lead wire length of the valves with lead wire is 300 mm. When ordering a lead wire length of 600 mm or longer, list the part numbers for the valve without connector and the connector assembly. Example) For lead wire length of 1000 mm: SQ1140-5LO-C63 pcs. AXT661-14ANL-103 pcs.

Connector Assembly Part No.


Lead wire length Socket only (3 pcs.) 300 mm 600 mm 1000 mm 2000 mm 3000 mm AXT661-14AL AXT661-14AL-6 AXT661-14AL-10 AXT661-14AL-20 AXT661-14AL-30 Single solenoid Double solenoid AXT661-13AL AXT661-13AL-6 AXT661-13AL-10 AXT661-13AL-20 AXT661-13AL-30 AXT661-12AL

Connector Assembly Part no.


Lead wire length Socket only (3 pcs.) 300 mm 600 mm 1000 mm 2000 mm 3000 mm AXT661-14ANL AXT661-14ANL-6 AXT661-14ANL-10 AXT661-14ANL-20 AXT661-14ANL-30 Single solenoid Double solenoid AXT661-13ANL AXT661-13ANL-6 AXT661-13ANL-10 AXT661-13ANL-20 AXT661-13ANL-30 AXT661-12AL

Note) When using the negative common specifications, use valves for negative common.

2-3-96

Plug Lead Unit

Series

SQ2000

5.25 58 33.4 18 (Mounting hole dimension) 8.5 Lead wire length: 300 M5: External pilot port 7 41.8 23 1 P = 17.5

L4 L3 L2 L1 28.8 Indicator light

VQC SQ VQ0
Manual override

147 (3 position) 131.5 [Single, Double, Dual 3 port valve]

VQ4 VQ5

10.4 5.4

(131.5)

122.3

35 5.5

70

47.5

12

12

EXH outlet D side C10: EXH port C10: SUP port


R 3

Stations

U side 10

For top ported

18.5

37.6 53.6

56

(58) 39.5 21

30 48.7

7.5

P = 17.5 2n-C4, C6, C8 (4(A), 2(B) port) C4: One-touch fitting for 4 C6: One-touch fitting for 6 C8: One-touch fitting for 8

Dimensions
L L1 L2 L3 L4 n 1 63.5 77.5 100 110.5 2 81 95 125 135.5 3 98.5 112.5 137.5 148

Formula: L1 = 17.5n + 46, L2 = 17.5n + 60 4 116 130 150 160.5 5 133.5 147.5 175 185.5 7 6 151 168.5 165 182.5 187.5 212.5 198 223 8 186 200 225 235.5 9 203.5 217.5 237.5 248 10 221 235 262.5 273

n: Stations (Maximum 16 stations) 12 256 270 300 310.5 13 273.5 287.5 312.5 323 14 291 305 325 335.5 15 308.5 322.5 350 360.5 16 326 340 362.5 373

11 238.5 252.5 275 285.5

25.5 41.5

2-3-97

62

B 2

A 4

1.TURN

2.PUSH

1.TURN

2.PUSH

2-M4 clamp screw

VQZ VQD

Series

SQ1000/2000

Manifold Option Parts for SQ1000


Blanking plate SSQ1000-10A-4
It is used by attaching on the manifold block for being prepared for removing a valve for maintenance reasons or planning to mount a spare valve, etc.

JIS Symbol
47 11.5

SUP/EXH block SSQ1000-PR-4-C8-


Option
Nil Description/Model Standard External pilot specifications Built-in silencer Valve Single Stations 4 1 2 3 4 5

R S

Note) When specifying both options, indicate -RS. Specify the spacer mounting position on the manifold specification sheet. For standard type manifolds, the SUP/EXH block is mounted on the D side. It is added to the manifold to increase SUP/EXH capacity. The number of SUP/EXH blocks that can be added is limited to two sets, one between manifold stations and another on the U side of the manifold, due to the length of the lead wire. SUP/EXH blocks are not included in the number of manifold stations. U side

Option

SUP/EXH block SSQ1000-PR-4-C8-

D side
3 (R) 1 (P)

Valve

Valve

Valve SUP/EXH block U side


3 (R) 1 (P)

D side
18

BA

BA

BA

PR

Individual SUP spacer


SSQ1000-P-4- C6
Port location
C6 Side ported L6 Top ported
This is used as a supply port for different pressures when using different pressures in the same manifold (for one station). Both sides of the station which is used with supply pressure from the individual SUP spacer are shut off. (Refer to application example.) Specify the spacer mounting position and SUP passage shut off positions on the manifold specification sheet. Two shut off positions are required per unit. (Two pieces of SUP block plate that shut off the supply pressure are included with the individual SUP spacer, therefore, it is not necessary to order them separately.) Electrical wiring is also connected to the manifold station with the individual EXH spacer. By changing the fitting shown in the drawing and the block plates, the spacers specification can be changed later (from the individual SUP spacer to the individual EXH spacer). The number of spacers is not limited when ordered with the manifold. However, when adding individual for F, P, and J kits, it is limited to two units, one between manifold stations and another on the U side, due to the length of the lead wire. Model no with manifold block: SSQ1000-P-4- C6-M L6

Side ported

U side

Description/Model Valve Single

Stations 1 2 3 4 5

D side Option

Top ported

Individual SUP spacer SSQ1000-P-4-C6 L6 SUP shut off position: Specify 2 positions. SUP block plate (Ordering not required) Valve U side
3 (R) 1 (P)

SUP block plate (Ordering not required) D side


Manifold block For top ported 9
3 (R) 1 (P)

Valve

Individual SUP spacer Valve

Individual SUP port 11.5

One-touch fittings for 6

2-3-98

26

47

60

BA

BA

BA

Plug Lead Unit

Series

SQ1000/2000

Individual EXH spacer SSQ1000-R-4- C6


Port location
C6 Side ported L6 Top ported
This is used to exhaust an individual valve when the exhaust from a valve interferes with other stations in the circuit (used for one station). Both sides of the station which is to be individually exhausted are shut off. (Refer to application example.) Specify the spacer mounting position and EXH passage shut off positions on the manifold specification sheet. Two shut off positions are required per unit. (Two pieces of EXH block plate that shut off the exhaust are included with the individual EXH spacer, therefore, it is not necessary to order them separately.) Electrical wiring is also connected to the manifold station with the individual EXH spacer. By changing the fitting shown in the drawing and the block plates, the spacers specification can be changed later (from the individual EXH spacer to the individual SUP spacer). The number of spacers is not limited when ordered with the manifold. However, when adding individual for F, P, and J kits, it is limited to two units, one between manifold stations and another on the U side, due to the length of the lead wire. Model no. with manifold block: SSQ1000-R-4- C6-M L6

Side ported

Stations Description/Model Valve U side Single

1 2 3 4 5

Top ported
Option D side Individual EXH spacer SSQ1000-R-4-C6 L6 EXH shut off position: Specify 2 positions. EXH block plate (Ordering not required) D side
Manifold block 9 For top ported
3 (R) 1 (P)

VQC SQ VQ0
EXH block plate (Ordering not required) Valve U side
3 (R) 1 (P)

VQ4 VQ5 VQZ VQD

Valve

Individual EXH Valve spacer

60

11.5

Individual EXH port

One-touch fittings for 6

Individual SUP/EXH spacer


SSQ1000-PR1-4- C6
Port location
C6 Side ported L6 Top ported

Side ported

37

47

BA

BA

BA

Description/Model Valve U side Single

Stations 1 2 3 4 5

11.5

Individual SUP port

One-touch fittings for 6

26

37

This has both functions of the individual SUP and EXH spacers above. Top ported D side (Refer to application example.) Specify the spacer mounting position and SUP and EXH passage shut off positions on the manifold specification sheet. Two shut off positions each for SUP and EXH are required per unit. (Two pieces each of block plate that shut off the SUP and EXH passages are included with the individual SUP/EXH spacer.) Electrical wiring is also connected to the maniManifold block fold station with the individual EXH spacer. By changing the fitting shown in the drawing Individual EXH port and the block plates, the spacers specification For top ported One-touch fittings for 6 can be changed later. The number of spacers is not limited when ordered with the manifold. However, when adding individual for F, P, and J kits, it is limited to two units, one between manifold stations and another on the U side, due to the length of the lead wire. Model no. with manifold block: SSQ1000-PR1-4-C6 -M L6

Option D side
9
3 (R) 1 (P)

Individual SUP/EXH spacer SSQ1000-PR1-4-C6 L6 SUP shut off position: Specify 2 positions. EXH shut off position: Specify 2 positions. Block plate Block plate (Ordering not required) (Ordering not required) Individual SUP EXH spacer Valve Valve Valve U side
3 (R) 1 (P)

60

47

BA

PR

BA

BA

2-3-99

Series

SQ1000/2000

Manifold Option Parts for SQ1000


SUP block plate SSQ1000-B-P
When supplying two different pressures, high and low, to one manifold, this is used between stations with different pressures. Also, it is used with an individual SUP spacer to shut off the air supply. Specify the station position on the manifold specification sheet.
R P

D side
6.5 5 O-ring 5 O-ring 5.3 4.9 3.6 5

<Shut off label>


When a SUP passage is shut off with a SUP block plate, a label is attached for external confirmation of the shut off position (one label each). Shut off labels are applied when SUP block plates are ordered with manifolds.

SUP passage

U side

R P
SUP passage blocked

R P
SUP/EXH passage blocked

EXH block plate


When the exhaust from a valve interferes with other stations in the circuit, this is used between stations to separate exhausts. Also, it is used with an individual EXH spacer to shut off the exhaust of individual valves. Specify the station position on the manifold specification sheet.
R P

SSQ1000-B-R

8.5

<Shut off label>


When an EXH passage is shut off with an EXH block plate, a label is attached for external confirmation of the shut off position (one label each). Shut off labels are applied when EXH block plates are ordered with manifolds.
EXH passage

U side

R P
EXH passage blocked

R P
SUP/EXH passage blocked

Back pressure check valve [-B] SSQ1000-BP


This prevents cylinder malfunction caused by the exhaust from other valves.It is inserted into the R (EXH) port of the valve that is affected. It is especially effective when using single acting cylinders or exhaust center type solenoid valves. When installing back pressure check valves only on the stations required, enter the part number and specify the station positions on a manifold specification sheet. When installing back pressure check valves on all of the stations, indicate -B at the end of the manifold part number.

Caution
1. Although the back pressure check valve is an assembly part with a check valve mechanism, a small amount of air leakage is allowed. Therefore, take care not to restrict the exhaust air from the exhaust port. 2. The effective area of valves is about 20% less when the back pressure check valve is installed. 3. Since 4 port specification valves (5 (R1) and 3 (R2) are common) are used, back pressure cannot be prevented with dual 3 port valves.

2-3-100

6.2

D side

Plug Lead Unit

Series

SQ1000/2000

Name plate [-N] SSQ1000-N3-Stations (1 to maximum)


This is a clear resin plate for applying solenoid valve function description labels, etc. To install, bend the plate slightly as shown and insert into the slots on the end plate side. Also, the plate is difficult to bend for manifolds with only a few stations, therefore, remove the silencer cover to install it. When ordering with manifolds, add -N at the end of the manifold number. P = 11.5

1 40.5

n: Stations

VQC SQ

Silencer cover

VQ0 VQ4

Blanking plug (For One-touch fitting)


23 KQ2P- 04 06 08
This is inserted into cylinder ports and SUP and EXH ports that are not used. Purchasing order is available in units of 10 pieces.

L A

Dimensions
Applicable fittings size (d) 3.2 4 6 8 D Model KQ2P-23 KQ2P-04 KQ2P-06 KQ2P-08 A 16 16 18 20.5 L 31.5 32 35 39 D 3.2 6 8 10

VQ5 VQZ VQD

Port plug VVQZ100-CP


This is used to close the cylinder ports when changing a 5 port valve to a 3 port valve. Add A or B at the end of the valve part number when ordering with valves. Example) SQ1141-5L-C6-A (N.O. specifications) 4 (A) port plug Example) SQ1141-5L-C6-B (N.C. specifications) 2 (B) port plug Example) SQ1141-5L-C6-B-M (B port plug with manifold block)
O-ring 9

A port 10 B port EXH outlet

Direct EXH outlet, built-in silencer [-S]


The EXH outlet is placed on the top side of the manifold end plate. The built-in silencer provides highly effective noise reduction. (Noise reduction of 30 dB) Note) Note that when excessive drainage occurs in the air supply, the drainage will be released along with the exhaust. Add -S at the end of the manifold part number when ordering with manifolds. For precautions on handling and how to replace elements, refer to page 2-3-5.

2-3-101

Series

SQ1000/2000
External pilot port (M5 x 0.8) SUP/EXH block

Manifold Option Parts for SQ1000


External pilot specifications [-R]
This can be used when the air pressure is 0.1 to 0.2 MPa lower than the minimum operating pressure of the solenoid valves or used for vacuum specifications. Add R to the part numbers of manifolds and valves to indicate the external pilot specification. An M5 port will be installed on the top side of the manifolds SUP/EXH block. How to order valves (Example) SQ1140 R -5L-C6 External pilot specifications How to order manifold (Example) Indicate R for an option. SS5Q14-08FD1-DR External pilot specifications

Note 1) Not applicable for dual 3 port valves. Note 2) Indicate RY for low wattage types. Note 3) Valves with the external pilot specifications have a pilot EXH with individual exhaust specifications and EXH can be pressurized. However, the pressure supplied from EXH should be 0.4 MPa or lower.

Dual flow fitting SSQ1000-52A- C8


Port size
C8 N9
8 5/16"

C8: 8 One-touch fitting N9: 5/16" One-touch fitting

This is inserted into the centralized type EXH port (One-touch fitting).

Applicable fittings size 8

Silencer (For EXH port)

24

To drive a large bore cylinder, two valve stations are operated simultaneously to double the air flow. This fitting is used on the cylinder ports in this situation. Available sizes are 8 and 5/16" One-touch fitting. When ordering with valves, specify the valve part number without One-touch fitting and list the dual flow fitting part number. Example) Valve part number (without One-touch fitting part number) SQ1141-5L- C0 2 sets C8 SSQ1000-52A- N9 1 set

22.8

2 B

39

29.5

77.8 59.3

SM

AN

0 20

Specifications
Series SQ1000 Effective area (mm2) Noise reduction (Cv factor) (dB) 20 (1.1) 30 AN200-KM8 Model

2-3-102

22

Plug Lead Unit Manifold Option Parts for SQ2000


Blanking plate SSQ2000-10A-4
It is used by attaching on the manifold block for being prepared for removing a valve for maintenance reasons or planning to mount a spare valve, etc.

Series

SQ1000/2000

JIS Symbol
55.5

17.5

VQC SQ

SUP/EXH block SSQ2000-PR-3-C10Option


Nil Description/Model Standard External pilot specifications Built-in silencer Valve Single Stations 4 1 2 3 4 5

VQ0 VQ4 VQ5 VQZ VQD

R S

Note) When specifying both options, indicate RS. Specify the spacer mounting position on the manifold For standard type manifolds, the SUP/EXH block is mounted on the D side. It is added to the manifold to increase SUP/EXH capacity. The number of SUP/EXH blocks that can be added is limited to two sets, one between manifold stations and another on the U side of manifold, due to the length of the lead wire. SUP/EXH blocks are not included in the number of manifold stations.

U side D side
3 (R) 1 (P)

Option

SUP/EXH block SSQ2000-PR-3-C10-

Valve

Valve Valve SUP/EXH block U side


3 (R) 1 (P)

D side

20

BA

BA

BA

PR

Individual SUP spacer SSQ2000-P-4- C8


Port location
C8 Side ported L8 Top ported
This is used as a supply port for different pressures when using different pressures in the same manifold (for one station). Both sides of the station which is used with supply pressure from the individual SUP spacer are shut off. (Refer to application example.) Specify the spacer mounting position and SUP passage shut off positions on the manifold specification sheet. Two shut off positions are required per unit. (Two pieces of SUP block plate that shut off the supply pressure are included with the individual SUP spacer, therefore, it is not necessary to order them separately.) Electrical wiring is also connected to the manifold station with the individual EXH spacer. By changing the fitting shown in the drawing and the block plates, the spacers specification can be changed later (from the individual SUP spacer to the individual EXH spacer). The number of spacers is not limited when ordered with the manifold. However, when adding individual for F, P, and J kits, it is limited to two units, one between manifold stations and another on the U side, due to the length of the lead wire. Model no. with manifold block: SSQ2000-P-4- C8 -M L8

Side ported

Description/Model Valve U side Single

Stations 1 2 3 4 5

Top ported
D side Option

Individual SUP spacer SSQ2000-P-4-C8 L8 SUP shut off position: Specify 2 positions.

SUP block plate (Ordering not required) D side


Manifold block For top ported 10
3 (R) 1 (P)

SUP block plate (Ordering not required) Valve U side


3 (R) 1 (P)

Valve

Individual SUP spacer Valve

BA
55.5 62

BA

BA

17.5

Individual SUP port

One-touch fitting for 8

25.5

2-3-103

Series

SQ1000/2000
Side ported

Manifold Option Parts for SQ2000


Individual EXH spacer SSQ2000-R-4- C8
Port location
Valve

C8 Side ported L8 Top ported


This is used to exhaust an individual valve when the exhaust from a valve interferes with other stations in the circuit (used for one station). Both sides of the station which is to be individually exhausted are shut off. (Refer to application example.) Specify the spacer mounting position and EXH passage shut off positionson the manifold specification sheet. Two shut off positions are required per unit. (Four pieces of EXH block plate that shut off the exhaust are included the exhaust are included with the individual EXH spacer, therefore, it is not necessary to order them separately.) Electrical wiring is also connected to the manifold station with the individual EXH spacer. By changing the fitting shown in the drawing and the block plates, the spacers specification can be changed later (from the individual EXH spacer to the individual SUP spacer) The number of spacers is not limited when ordered with the manifold. However, when adding individual for F, P, and J kits, it is limited to two units, one between manifold stations and another on the U side, due to the length of the lead wire. Model no. with manifold block: SSQ2000-R-4- C8 -M
L8

Description/Model U side Single

Stations 1 2 3 4 5

Top ported

Option

D side

Individual EXH spacer SSQ2000-R-4- C8 L8 EXH shut off position: Specify 2 positions.

EXH block plate (Ordering not required) Valve

D side
Manifold block For top ported 10 3 (R) 1 (P)

EXH block plate (Ordering not required) Individual EXH Valve Valve spacer

U side
3 (R) 1 (P)

41.5 55.5 62

BA

BA

BA

17.5

Individual EXH port

One-touch fitting fo 8

Individual SUP/EXH spacer SSQ2000-PR1-4- C8


Port location
C8 Side ported L8 Top ported
This has both functions of the individual SUP and EXH spacers above. (Refer to application example.) Specify the spacer mounting position and SUP and EXH passage shut off positions on the manifold specification sheet. Two shut off positions each for SUP and EXH are required per unit. [Block plates that shut off the SUP and EXH passages are included with the individual SUP/EXH spacer (2 pcs. of SUP block plate and 4 pcs. of EXH block plate).] Electrical wiring is also connected to the manifold station with the individual EXH spacer. By changing the fitting shown in the drawing and the block plates, the spacers specification can be changed later. The number of spacers is not limited when ordered with the manifold. However, when adding individual for F, P, and J kits, it is limited to two units, one between manifold stations and another on the U side, due to the length of the lead wire. Model no. with manifold block: SSQ2000-PR1-4- C8 -M L8

Side ported
Stations Description/Model Valve Single 1 2 3 4 5

U side

Top ported

Option

D side

Individual SUP/EXH spacer SSQ2000-PR1-4- C8 L8 SUP shut off position: Specify 2 positions. EXH shut off position: Specify 2 positions. Block plate (Ordering not required) D side Valve Block plate (Ordering not required) Valve U side
3 (R) 1 (P)

Individual SUP EXH Valve spacer


3 (R) 1 (P)

Manifold block For top ported

One-touch fitting fo 8

25.5 41.5 55.5

62

10

Individual EXH port

BA

PR

BA

BA

17.5

Individual SUP port

One-touch fitting fo 8

2-3-104

Plug Lead Unit

Series

SQ1000/2000

SUP block plate


When supplying two different pressures, high and low, to one manifold, this is used between stations with different pressures. Also, it is used with an individual SUP spacer to shut off the air supply. Specify the station position on the manifold specification sheet.
R P

SSQ1000-B-R

8.5

D side
6.2 5 O-ring 5.2 O-ring 9.4 8.3

VQC SQ VQ0 VQ4 VQ5 VQZ VQD

<Shut off label>


When a SUP passage is shut off with a SUP block plate, a label is attached for external confirmation of the shut off position (one label each). Shut off labels are applied when SUP block plates are ordered with manifolds.
SUP passage

U side

R P R
SUP passage blocked

R P R
SUP/EXH passage blocked

EXH block plate SSQ2000-B-R


When the exhaust from a valve interferes with other stations in the circuit, this is used between stations to separate exhausts. Also, it is used with an individual EXH spacer to shut off the exhaust of individual valves. Specify the station position on the manifold specification sheet.
R P

10

9.2

D side
4.6

<Shut off label>


When an EXH passage is shut off with an EXH block plate, a label is attached for external confirmation of the shut off position (one label each). Shut off labels are applied when EXH block plates are ordered with manifolds.

U side
EXH passage

R P R
EXH passage blocked

R P R
SUP/EXH passage blocked

Back pressure check valve [-B] SSQ2000-BP


This prevents cylinder malfunction caused by the exhaust from other valves. It is inserted into the R (EXH) port of the valve that is affected. It is especially effective when using single acting cylinders or exhaust center type solenoid valves. When installing back pressure check valves only on the stations required, enter the part number and specify the station positions on a manifold specification sheet. When installing back pressure check valves on all of the stations, indicate -B at the end of the manifold part number.

Set of 2 pcs.

Caution
1. Although the back pressure check valve is an assembly part with a check valve mechanism, a small amount of air leakage is allowed. Therefore, take care not to restrict the exhaust air from the exhaust port. 2. The effective area of valves is about 20% less when the back pressure check valve is installed.

2-3-105

Series

SQ1000/2000

Manifold Option Parts for SQ2000


Name plate [-N] SSQ2000-N3- Stations (1 to maximum)
This is a clear resin plate for applying solenoid valve function description labels, etc. To install, bend the plate slightly as shown and insert into the slots on the end plate side. Also, the plate is difficult to bend for manifolds with only a few stations, therefore, remove the silencer cover to install it. When ordering with manifolds, add -N at the end of the manifold number. P = 17.5

1 53

n: Stations

Silencer cover

Blanking plug (For One-touch fitting)


04 06 KQ2P- 08 10
This is inserted into cylinder ports and SUP and EXH ports that are not used. Purchasing order is available in units of 10 pieces.

L A

Dimensions
Applicable fittings size (d) 4 6 8 10 Model KQ2P-04 KQ2P-06 KQ2P-08 KQ2P-10 A 16 18 20.5 22 L 32 35 39 43 D 6 8 10 12

Port plug VVQZ2000-CP


This is used to close the cylinder ports when changing a 5 port valve to a 3 port valve. Add A or B at the end of the valve part number when ordering with valves. Example) SQ2141-5L-C8-A (N.O. specifications) 4(A) port plug Example) SQ2141-5L-C8-B (N.C. specifications)
O-ring 9.7

A port

2(B) port plug Example) SQ2141-5L-C8-B-M (B port plug with manifold block)
B port

Direct EXH outlet, built-in silencer [-S]


The EXH outlet is placed on the top side of the manifold end plate. The built-in silencer provides highly effective noise reduction. (Noise reduction of 30 dB) Note) Note that when excessive drainage occurs in the air supply, the drainage will be released along with the exhaust. Add S at the end of the manifold part number when ordering with manifolds. For precautions on handling and how to replace elements, refer to page 2-3-5.
EXH outlet

2-3-106

14

Plug Lead Unit

Series

SQ1000/2000

External pilot specifications [-R]


This can be used when the air pressure is 0.1 to 0.2 MPa lower than the minimum operating pressure of the solenoid valves or used for vacuum specifications. Add R to the part numbers of manifolds and valves to indicate the external pilot specifications. An M5 port will be installed on the top side of the manifolds SUP/EXH block. How to order valves (Example) SQ2140 R -5L-C6 External pilot specifications How to order manifold (Example) Indicate R for an option. SS5Q24-08FD1-DR External pilot specifications

External pilot port (M5 x 0.8) SUP/EXH block

VQC SQ VQ0
Note 1) Not applicable for dual 3 port valves. Note 2) Indicate RY for low wattage types. Note 3) Valves with the external pilot specifications have a pilot EXH with individual exhaust specifications and EXH can be pressurized. However, the pressure supplied from EXH should be 0.4 MPa or lower.

VQ4 VQ5 VQZ VQD

Dual flow fitting SSQ2000-52A- C10


Port size
C10 N11
10 3/8" C10: 10 One-touch fitting N11: 3/8" One-touch fitting

This is inserted into the centralized type EXH port (One-touch fitting).

Applicable fittings size 10

Silencer (For EXH port)

24.7 44.2

To drive a large bore cylinder, two valve stations are are operated simultaneously to double the air flow.This fitting is used on the cylinder ports in this situation. Available sizes are 10 and 3/8" One-touch fittings. When ordering with valves, specify the valve part number without One-touch fitting and list without One-touch fitting and list the dual flow fitting part number. Example) Valve part number (without Onetouch fitting) SQ2141-5L- C0 2 sets C10 SSQ2000-52A- N11 1 set

29.3

38

80.8 59.6

SM

0 N2

Specifications
Effective area (mm2) Noise reduction (Cv factor) (dB) 26 (1.4) 30 SQ2000 AN200-KM10 Series Model

2-3-107

22

Series

SQ1000/2000

Manifold Option Parts for SQ1000/SQ2000


Special Wiring Specifications
In the internal wiring of F kit, P kit, and J kit, double wiring (connected to SOL. A and SOL. B) is adopted for each station regardless of the valve and option types. Mixed single and double wiring is available as an option.

1. How to order
Indicate option symbol -K in the manifold part number and be sure to specify station positions for single or double wiring on the manifold specification sheet. Example) SS5Q14-

09 FD0 - DKS
Others, option symbols: to be indicated alphabetically.

2. Wiring specifications
Connector terminal numbers are connected from solenoid station 1 on the A side in the order indicated by the arrows without skipping any terminal numbers.

COM.
26 14 15 16 17 18 19 20 21 22 23 24 25 1 2 3 4 5 6 7 8 9 10 11 12 13 24 22 20 18 16 14 12 10 8 6 4 25 23 21 19 17 15 13 11 9 7 5 3 1

COM.

COM.
20 18 16 14 12 10 8 6 4 2 19 17 15 13 11 9 7 5 3 1

COM.
20 18 16 14 12 10 8 6 4 2 19 17 15 13 11 9 7 5 3 1

COM.

COM. F kit D-sub connector (for 25P) P kit Flat ribbon cable connector (for 26P) P kit Flat ribbon cable connector (for 20P)

COM.

J kit Flat ribbon cable connector (20P) PC Wiring System compatible

3. Maximum stations
The maximum number of manifold stations is determined by the number of solenoids. Count one point for a single solenoid type and two points for a double solenoid type. Determine the number of stations so that the total number of solenoids is no more than the maximum points in the table below. Kit Type Max. points F kit (D-sub connector) FD 25P 24 points P kit (Flat ribbon cable connector) PD 26P 24 points PDC 20P 18 points
J kit Flat ribbon cable PC Wiring System compatible

JD0 20P 16 points

Note) Maximum stations SQ1000: 24 stations SQ2000: 16 stations

2-3-108

Plug Lead Unit

Series

SQ1000/2000

Special DIN Rail Length (DIN rail mounting (-D) only)


The standard DIN rail provided is approximately 30 mm longer than the overall length of the manifold with a specified number of stations. The following options are also available.

DIN rail length longer than the standard type (for stations to be added later, etc.)
In the manifold part number, specify -D for the manifold mounting symbol and add the number of required stations after the symbol. Example) SS5Q14-

VQC SQ VQ0 VQ4

08FD0 - D09BNK
Option symbols (alphabetically) DIN rail for 9 stations

8 station manifold

Ordering DIN rail only


DIN rail part number

VQ5 VQZ VQD

AXT100- DR - n

Note) For n, enter a number from the No. line in the table below. For L dimension, refer to the dimensions of each kit. L

1.25

P = 12.5

5.25

7.5

35

L Dimension
No. L dimension No. L dimension No. L dimension No. L dimension 1 23 11 148 21 273 31 398 2 35.5 12 160.5 22 285.5 32 410.5 3 48 13 173 23 298 33 423 4 60.5 14 185.5 24 310.5 34 435.5 5 73 15 198 25 323 35 448 6 85.5 16 210.5 26 335.5 36 460.5 7 98 17 223 27 348 37 473 8 110.5 18 235.5 28 360.5 38 485.5 9 123 19 248 29 373 39 498

5.5

25

L = 12.5 x n + 10.5

10 135.5 20 260.5 30 385.5 40 510.5

Direct Mounting Style (-E) (SQ2000 C kit only)


Manifold is mounted by using mounting holes of both sides of the manifold. DIN rail is not sticking out of the edge of end plate.

Mounting hole (For M5)

Mounting hole (For M5)

2-3-109

Series

SQ1000/2000

Manifold Option for SQ1000/SQ2000


Negative Common Specifications
The following valve part numbers are for negative COM specifications. Manifold part numbers are the same as standard.

How to order negative COM valves (Example) SQ1140 N -5L-C6


Negative common specifications

Inch-size One-touch Fittings


For One-touch fittings in inch sizes, use the following part numbers. Also, the color of the release button is orange.

How to order valves (Example) SQ1140-5LPort location


Nil Side ported Top ported

N7 Cylinder port
Symbol Applicable tubing O.D. (Inch) SQ1000 4(A), 2(B) port SQ2000 N1 1/8" N3 5/32" N7 1/4" N9 5/16"

How to order manifold (Example)


Add 00T at the end of the part number.

SS5Q14- 08 FD0-DN - 00T


1 (P), 3 (R) port in inch size SQ1000: 5/16" (N9) SQ2000: 3/8" (N11)

2-3-110

Plug Lead Unit How to Add Manifold Stations for SQ1000/SQ2000


1. How to Add Manifold Stations What to order

Series

SQ1000/2000

Valves with manifold block (refer to pages 2-3-71 and 2-3-85) or the manifold blocks shown below. For F kit, P kit, and J kit, also order the lead wire assemblies in the next section.

Manifold Block Part No. SQ1000

VQC
SQ2000

SQ VQ0 VQ4 VQ5 VQZ VQD

SSQ1000

1A

SSQ2000

1A

Option
Nil B R
None Back pressure check valve External pilot specifications

Option
Nil B R
None Back pressure check valve External pilot specifications

Note) Enter -BR for both options.

Note) Enter -BR for both options.

2-3-111

Series

SQ1000/2000

How to Add Manifold Stations for SQ1000/SQ2000


For F kit, P kit, J kit What to order: Lead wire assembly

SQ1000
D-sub connector kit (F kit) For single wiring

SSQ1000

40A

F
L

205
Stations Symbol (L dimension) Stations Symbol (L dimension) Station 2 Station 3 Station 4 Station 5 Station 6 Station 7 165 175 190 205 215 230 245 260 280 290 300 310 Station 14 Station 15 Station 16 Station 17 Station 18 Station 19 Station 20 Station 21 Station 22 Station 23 Station 24 320 335 250 365 375 385 400 405 420 435 450

For double wiring

SSQ1000

Flat ribbon cable kit (P kit), PC Wiring System compatible (J kit) For single wiring

SSQ1000

For double wiring

SSQ1000

A CB

41A

F
L

280

Station 8 Station 9 Station 10 Station 11 Station 12 Station 13

A CB

40A

P
L

200
Stations Symbol (L dimension) Stations Symbol (L dimension) Station 2 160 170 185 200 210 225 240 255 275 285 295 305 Station 14 Station 15 Station 16 Station 17 Station 18 Station 19 Station 20 Station 21 Station 22 Station 23 Station 24 315 330 345 360 370 380 395 400 415 430 445 Station 3 Station 4 Station 5 Station 6 Station 7

A CB

41A

P
L

275

Station 8 Station 9 Station 10 Station 11 Station 12 Station 13

A CB

2-3-112

Plug Lead Unit

Series

SQ1000/2000

SQ2000
D-sub connector kit (F kit)

VQC
For single wiring

SQ

SSQ1000

40A

F
L

250
Stations Symbol (L dimension) Stations Symbol (L dimension) Station 2 Station 3 Station 4 Station 5 Station 6 Station 7 190 210 230 250 270 290 310 330 250 370 390 410 Station 14 Station 15 Station 16 Station 17 Station 18 Station 19 Station 20 Station 21 Station 22 Station 23 Station 24 430 450 470 490 510 530 550 570 590 610 630

VQ0 VQ4 VQ5 VQZ VQD

For double wiring

SSQ1000

Flat ribbon cable kit (P kit), PC Wiring System compatible (J kit) For single wiring

SSQ1000

For double wiring

SSQ1000

A CB

41A

F
L

350

Station 8 Station 9 Station 10 Station 11 Station 12 Station 13

A CB

40A

P
L

250
Stations Symbol (L dimension) Stations Symbol (L dimension) Station 2 190 210 230 250 270 290 310 330 250 370 390 410 Station 14 Station 15 Station 16 Station 17 Station 18 Station 19 Station 20 Station 21 Station 22 Station 23 Station 24 430 450 470 490 510 530 550 570 590 610 630 Station 3 Station 4 Station 5 Station 6 Station 7

A CB

41A

P
L

350

Station 8 Station 9 Station 10 Station 11 Station 12 Station 13

A CB

2-3-113

Series

SQ1000/2000

How to Add Manifold Stations for SQ1000/SQ2000


Steps for adding stations
(1) Loosen the clamp screw on the U side end plate and open the manifold. (2) Mount the manifold block or valve with manifold block to be added. (3) Press on the end plate to eliminate any space between the manifold blocks and tighten the clamp screw.
(Proper tightening torque: 0.8 to 1.0 Nm)

(4) In the case of F kit, P kit or J kit, remove the connector housing from the DIN rail and connect the wiring.

(1)

U side

(1) (2) (3) D side (3)

(4)
Connector housing (F kit is shown.)

2-3-114

Plug Lead Unit

Series

SQ1000/2000

2. Connection Method
(1) Connecting common wire Insert the red lead wire (common wire) of the connector to be added into the adjacent connector as shown in the drawing below. After inserting,

Connector to be added

VQC SQ VQ0 VQ4 VQ5

White (SOL. B)

Black (SOL. A)

VQZ
Socket Red (COM wire)

VQD

(2) Pulling out connector

Housing

Pull out the connector to connect the lead wires for SOL. A and SOL. B. Insert a flat head screwdriver into the slot of the housing cover and remove it. Remove the manual lever and pull out the connector.

(F kit)

(P, J kit)

Connector

Protrusion Stopper Connector


Remove the stopper and pull out the connector.

Manual lever Spring

Housing cover Slot

F, P, J kit

2-3-115

Series

SQ1000/2000

How to Add Manifold Stations for SQ1000/SQ2000


(3) Connector connection/Connect the black and white lead wire pins to the positions shown below in accordance with each kit.

Caution 1.

After inserting the pin, confirm that the pin hook is locked by lightly pulling the lead wire. 2. Do not pull the lead wire forcefully when connecting. Also, take care that lead wires do not get caught between manifolds or when remounting the housing.

Wiring (F kit: D-sub connector kit)


Procedure) Based on the manifold specifications, station 1 of SOL..A (black wire) will be terminal number 1 of the D-sub connector, and for station 2 and thereafter, connect black wires, then white wires in the order as shown below by the arrows.
Lead wire assembly Connector terminal no. Station 1 Black, SOL. A
14

1 2 3 4 5 6 7 8 9

14 15 16 17 18

Station 2 Black, SOL. A Station 3 White, SOL. B Station 4 White, SOL. B 1 station Station 5 White, SOL. B 2 stations 3 stations SOL.A SOL.A SOL.A SOL.B SOL.A 4 stations SOL.B SOL.A 5 stations SOL.B SOL.A Terminal Lead wire no. color 1 14 2 15 3 16 4 17 5 Black Black Black White Black White Black White Black

Station 3 Black, SOL. A Station 4 Black, SOL. A Station 5 Black, SOL. A Station 6 Black, SOL. A

10

21

20

19

18

17

16

15

13 12

Black

11

23

22

19 20 21 22 23 24 25 6 stations

Red (COM) White Hook

25

24

10 11 12 COM 13

Manifold Specifications Example


Stations 1 Single wiring Double wiring 2 3 4 5 6

COM

The drawing above shows connections based on the manifold specification example in the table to the left.

13

Red

Wiring (P kit: Flat ribbon cable kit)


Procedure) Based on the manifold specifications, station 1 of SOL.A (black wire) will be terminal number 1B of the flat ribbon cable connector, and for station 2 and thereafter, connect black wires, then white wires in the order as shown below by the arrows.
Terminal no. Protrusion Lead wire assembly Station 2 Black, SOL. A Station 3 White, SOL. B Station 4 White, SOL. B Station 5 White, SOL. B 1A 2A 3A 4A 5A 6A 7A 8A 9A 10A Red (COM) 11A 12A 1B 2B 3B 4B 5B 6B 7B 8B 9B 10B 11B 12B 13B Red (COM) 6 stations SOL.A COM COM SOL.A 5 stations SOL.B SOL.A 4 stations SOL.B Station 1 Black, SOL. A Station 3 Black, SOL. A Station 4 Black, SOL. A 1 station Station 5 Black, SOL. A 2 stations Station 6 Black, SOL. A 3 stations SOL.A SOL.A SOL.A SOL.B Terminal Lead wire no. color 1B 1A 2B 2A 3B 3A 4B 4A 5B 13A 13B Black Black Black White Black White Black White Black Red Red

Manifold Specifications Example


Stations 1 Single wiring Double wiring 2 3 4 5 6

Red (COM)

13A

The drawing above shows connections for type 26P flat ribbon cable connector based on the manifold specification example in the table to the left. For type 20P, the connection will be the same as above except that COM changes to 10A and 10B.

2-3-116

Plug Lead Unit

Series

SQ1000/2000

Wiring (J kit: Flat ribbon cable, PC Wiring System compatible)


Procedure) Based on the manifold specifications, station 1 of SOL.A (black wire) will be terminal number 10A of the flat ribbon cable connector, and for station 2 and thereafter, connect black wires, then white wires in the order as shown below by the arrows.
Terminal no. Protrusion Red (COM) Lead wire assembly Unused Station 5 White Station 5 Black Red (COM) Station 4 White Station 4 Black Station 3 White Station 3 Black Station 2 Black Station 1 Black 1A 2A 3A 4A 5A 6A 7A 8A 9A 10A 1B 2B 3B 4B 5B 6B 7B 8B 9B 10B Station 6 Black 5 stations 6 stations 4 stations 3 stations 1 station 2 stations Red (COM) Unused SOL.A SOL.A SOL.A SOL.B SOL.A SOL.B SOL.A SOL.B SOL.A COM COM Terminal Lead wire no. color 10A 9A 8A 7A 6A 5A 4A 3A 10B 1A 1B Black Black Black White Black White Black White Black Red Red

VQC SQ VQ0 VQ4 VQ5 VQZ VQD

Manifold Specifications Example


Stations 1 Single wiring Double wiring 2 3 4 5 6

2-3-117

Series

SQ1000/2000
Rubber seal type Single: SQ1141
e q w r e q w

Construction: Series SQ1000 Plug Lead Type Main Parts and Pilot Valve Assembly
Metal seal type Single: SQ1140
r

SQ1140
(A)(B) 42

SQ1141
(A)(B) 42

51 3 (R1) (P)(R2)

51 3 (R1) (P)(R2)

Double (Latching): SQ1240


t e q w

Double (Latching): SQ1241


t e q w

SQ1240
(A)(B) 42

SQ1241
(A)(B) 42

51 3 (R1)(P)(R2)

51 3 (R1) (P)(R2)

Double (Double solenoid): SQ1240D


y e qw e

Double (Double solenoid): SQ1241D


y e q w e

SQ1240D
(A)(B) 42

SQ1241D
(A)(B) 42

513 (R1) (P)(R2)

51 3 (R1)(P)(R2)

3 position: SQ1 4 40 5
y e q w e

3 position: SQ14 41
5

u
SQ1340
(A)(B) 42

u
SQ1440
(A)(B) 42

SQ1540
(A)(B) 42

SQ1341
(A)(B) 42

SQ1441
(A)(B) 42

SQ1541
(A)(B) 4 2

51 3 (R1) (P)(R2)

513 (R1) (P)(R2)

513 (R1) (P)(R2)

51 3 (R1) (P)(R2)

51 3 (R1) (P)(R2)

513 (R1) (P)(R2)

Component Parts
No. q w e Body Spool/Sleeve Spool Piston Description Material Zinc die-casted Stainless steel (Metal seal) Aluminum (Rubber seal) Resin

Dual 3 port valve: SQ1 B 41 C


y e w qw e

Pilot Valve Assembly Note)


No. r t y u For single For double (Latching) Model

SQ14
VQ110 (Y) - 6 (N)J1(B) VQ110L- 6 J2 Negative COM: VQ110N- 5 J2 6
5 (K) 5

u
SQ1A41
4 5 2 3

SQ1B41
4 5 2 3

SQ1C41
4 5 2 3

For double (Double solenoid) on A side (K) 5 VQ110 (Y) - 6 (N)J3(B) For 3P, Dual 3 port on A side For double (Double solenoid) on B side (K) VQ111(Y)- 5 (N)J4 6 For 3P, Dual 3 port on B side
Note) Nil: Standard B : Locking type manual override K : High pressure specifications (metal seal only) N : Negative common specifications Y : Low wattage specifications

N.C.

N.C.

N.O.

N.O.

N.C.

N.O.

2-3-118

Plug Lead Unit

Series

SQ1000/2000

Construction: Series SQ2000 Plug Lead Type Main Parts and Pilot Valve Assembly
Metal seal type Single: SQ2140
r e q w
SQ2140
(A)(B) 42 51 3 (R1) (P)(R2)

Rubber seal type Single: SQ2141


r e q w
SQ2141
(A)(B) 42

51 3 (R1) (P)(R2)

VQC SQ VQ0

Double (Latching): SQ2240


t e q w
SQ2240
(A)(B) 42 51 3 (R1)(P)(R2)

Double (Latching): SQ2241


t e q w
SQ2241
(A) (B) 42

VQ4 VQ5 VQZ

51 3 (R1) (P)(R2)

Double (Double solenoid): SQ2240D


y e q we
SQ2240D
(A) (B) 42

Double (Double solenoid): SQ2241D


y e q w e
SQ2241D
(A)(B) 42 513 (R1)(P)(R2)

VQD

51 3 (R1) (P)(R2)

u
3 5

3 position: SQ2 4 40
y e q w e

3 position: SQ2 4 41 5
y e q w e

u
SQ2340
(A) (B) 42

u
SQ2440
(A) (B) 42 51 3 (R1)(P)(R2)

SQ2540
(A) (B) 4 2 513 (R1) (P)(R2)

SQ2341
(A) (B) 42

SQ2441
(A) (B) 42 51 3 (R1) (P) (R2)

SQ2541
(A) (B) 4 2 513 (R1) (P)(R2)

513 (R1) (P)(R2)

513 (R1)(P)(R2)

Dual 3 port valve: SQ2 B 41 C Component Parts


No. q w e Body Spool/Sleeve Spool Piston Description Material Aluminum die-casted Stainless steel (Metal seal) Aluminum (Rubber seal) Resin

w q w e

Pilot Valve Assembly Note)


No. r t y u For single For double (Iatching) Model

u
SQ24
VQ111S(Y)VQ110SL5 6 5 6

SQ2A41
4 5 5 6 J22 2 3

SQ2B41
4 5 2 3

SQ2C41
4 5 2 3

(N)J21
N.C.
1

J22

N.C.

N.O.

N.O.

N.C.

N.O.

Negative COM: VQ110SN-

For double (Double solenoid) on A side VQ111S(Y)- 5 (N)J23 6 For 3P, Dual 3 port on A side For double (Double solenoid) on B side VQ111S(Y)- 5 (N)J24 6 For 3P, Dual 3 port on B side
Note) Nil : Standard N : Negative COM specifications Y : Low wattage specifications

2-3-119

Series

SQ1000/2000

Exploded View of Manifold: SQ1000 (Plug lead type manifold) SS5Q14


(F, P, J, C kit)
Wiring unit assembly D side end plate assembly SUP/EXH block assembly Valve and manifold block assembly U side end plate assembly

e !2

F kit

t !1 !2 i u

P kit (26P/20P) J kit (20P)

!0 r o

P (J) kit

2-3-120

Plug Lead Unit Manifold Spare Parts

Series

SQ1000/2000

Refer to pages 2-3-112 to 2-3-117 of How to Add Manifold Stations regarding the mounting of each spare parts.

<q D-sub connector housing assembly>

<r D side end plate assembly>

AXT100

40

FL25
Wiring
S D

S 03
Stations
01
For 1 station

SSQ1000

3A 2A

4 4 4 C8
VQC SQ VQ0 VQ4 VQ5 VQZ VQD

Single wiring Double wiring

<t U side end plate assembly>

<w Flat ribbon cable connector housing assembly>

24 For 24 stations

SSQ1000

<y SUP/EXH block assembly>

AXT100
Wiring
S D

40
Single wiring Double wiring

PL26 PL20 JL20


01

S 03
Note) Note)

SSQ1000 PR
Port size
C6 C8 N7 N9

Stations

For 1 station

<e Lead wire assembly>


(For F kit)
For station 1

PL26: 01 to 24 (P kit, 26P) PL20: 01 to 18 (P kit, 20P) 24 For 24 stations JL20: 01 to 16 (J kit, 20P)

One-touch fitting for 6 One-touch fitting for 8 One-touch fitting for 1/4" One-touch fitting for 5/16"

Option
Nil R S Common exhaust type External pilot Built-in silencer, direct exhaust

SSQ1000
Wiring
0 1

41 B F

155 SSQ1000

Note) Enter -RS for both options.

For single (2-wire) For double (3-wire)

<u Manifold block assembly>

For 2 to station 24

SSQ1000
Wiring
0 1

41 A F

205

1A

Including gaskets !2

Option
Nil

For single (2-wire) For double (3-wire)


L dimension (mm)

Lead wire length


Stations Station 2 Station 3 Station 4 Station 5 Station 6 Station 7
L dimension (mm)

B R
Stations Station 20 Station 21 Station 22 Station 23 Station 24
L dimension (mm)

None Back pressure check valve External pilot specifications

Stations Station 8 Station 9 Station 10 Station 11 Station 12 Station 13

Stations Station 14 Station 15 Station 16 Station 17 Station 18 Station 19

L dimension (mm)

Note) Enter -BR for both options.

165 175 190 205 215 230

245 260 280 290 300 310

320 335 250 365 375 385

400 405 420 435 450

<i Element>

SSQ1000
<o Port plug>

SE

Note) Part number for a 10 piece set of elements. Refer to page 2-3-5 for replacement procedures.

(For P, J kit)
For station 1

VVQZ2000 CP 4 1 B P 150
Wiring
0 1
For single (2-wire) For double (3-wire)

SSQ1000

<!0 Fitting assembly>


(For P, R port)

VVQ1000 200
Port size
C6 C8 N7 N9
315 330 345 360 370 380 Stations L dimension (mm) Station 20 395 Station 21 400 Station 22 415 Station 23 430 Station 24 445

51A

C8

For 2 to station 24

SSQ1000
Wiring
0 1

41 A P

For single (2-wire) For double (3-wire)


L dimension (mm)

Lead wire length


Stations Station 2 Station 3 Station 4 Station 5 Station 6 Station 7
L dimension (mm)

One-touch fitting for 6 One-touch fitting for 8 One-touch fitting for 1/4" One-touch fitting for 5/16"

160 170 185 200 210 225

Stations Station 8 Station 9 Station 10 Station 11 Station 12 Station 13

240 255 275 285 295 305

Stations Station 14 Station 15 Station 16 Station 17 Station 18 Station 19

L dimension (mm)

Note) Purchasing order is available in units of 10 pieces

<!1 Fitting assembly>


(For cylinder port)

VVQ1000
Port size
C3 C4 C6 M5 N1 N3 N7

50A

C6

(For C kit)

AXT661
Wiring
3 4

1 3 AL
Lead wire length
Symbol L dimension (mm) Nil 300 6 600 10 1000 15 1500 20 2000 25 2500 30 3000 50 5000

For double (3-wire) For single (2-wire)

One-touch fitting for 3.2 One-touch fitting for 4 One-touch fitting for 6 M5 thread One-touch fitting for 1/8" One-touch fitting for 5/32" One-touch fitting for 1/4"

Note) Purchasing order is available in units of 10 pieces

<!2 Gasket and screw assembly>

SQ1000 GS
Note) Part number for 10 pieces each of gaskets and screws.

2-3-121

Series

SQ1000/2000

Exploded View of Manifold: SQ2000 (Plug lead type manifold) SS5Q24


(F, P, J, C kit)
Wiring unit assembly D side end plate assembly SUP/EXH block assembly Valve and manifold block assembly U side end plate assembly !2

t e y

F kit

i !2 u !0 r o

!1

P kit (26P/20P) J kit (20P)

P (J) kit

2-3-122

Plug Lead Unit Manifold Spare Parts

Series

SQ1000/2000

Refer to pages 2-3-112 to 2-3-117 of How to Add Manifold Stations regarding the mounting of each spare parts.

<q D-sub connector housing assembly>

<r D side end plate assembly>

AXT100

41

FL25
Wiring
S D

S 03
Stations
01
For 1 station

SSQ2000

3A

4
Manifold mounting
Nil E
DIN rail mount style Direct mount style

Single wiring Double wiring

12 For 12 stations

<w Flat ribbon cable connector housing assembly>

<t U side end plate assembly>

VQC

AXT100
Wiring
S D

41
Single wiring Double wiring

PL26 PL20 JL20


Stations
01

SSQ2000

2A

1
Manifold mounting
Nil E
DIN rail mount style Direct mount style

SQ VQ0 VQ4

S 03
Note)

<y SUP/EXH block assembly>

<e Lead wire assembly>


(For F kit)
For station 1

For 1 station Note) PL26: 01 to 12 (P kit, 26P) PL20: 01 to 09 (P kit, 20P) 12 For 12 stations JL20: 01 to 08 (J kit, 20P)

SSQ2000
Port size

PR 3

C10
Option
Nil R S Common exhaust type External pilot Built-in silencer, direct exhaust
Note) Enter -RS for both options.

VQ5 VQZ VQD

SSQ1000
Wiring
0 1

41 B F

170

One-touch fitting for 8 C8 C10 One-touch fitting for 10 N9 One-touch fitting for 5/16" N11 One-touch fitting for 3/8"

For single (2-wire) For double (3-wire)

For 2 to station 24

SSQ1000
Wiring
0 1

41 A F

230

<u Manifold block assemblies>

SSQ2000

1A

Including gaskets !2

For single (2-wire) For double (3-wire)


L dimension (mm)

Option
Nil Stations L dimension (mm) Station 20 550 Station 21 570 Station 22 590 Station 23 610 Station 24 630

Lead wire length


Stations Station 2 Station 3 Station 4 Station 5 Station 6 Station 7
L dimension (mm)

190 210 230 250 270 290

Stations Station 8 Station 9 Station 10 Station 11 Station 12 Station 13

310 330 250 370 390 410

Stations L dimension (mm) Station 14 430 Station 15 450 Station 16 470 Station 17 490 Station 18 510 Station 19 530

B R

None Back pressure check valve External pilot specifications

<i Element>

Note) Enter -BR for both options.

SSQ2000
<o Port plug>

SE

Note) Part number for a 10 piece set of elements. Refer to page 2-3-5 for replacement procedure.

(For P, J kit)
For station 1

SSQ1000
Wiring
0 1

4 1 B P 170

VVQZ3000 CP
<!0 Fitting assembly>
(For P, R port)

For single (2-wire) For double (3-wire)

For 2 to station 24

SSQ1000
Wiring
0 1

41 A P

310

VVQ2000

51A

C10
Port size

For single (2-wire) For double (3-wire)


L dimension (mm)

Lead wire length


Stations Station 2 Station 3 Station 4 Station 5 Station 6 Station 7
L dimension (mm)

190 210 230 250 270 290

Stations Station 8 Station 9 Station 10 Station 11 Station 12 Station 13

310 330 250 370 390 410

Stations Station 14 Station 15 Station 16 Station 17 Station 18 Station 19

L dimension (mm)

430 450 470 490 510 530

Stations L dimension (mm) Station 20 550 Station 21 570 Station 22 590 Station 23 610 Station 24 630

One-touch fitting for 8 C8 C10 One-touch fitting for 10 Note) Purchasing order N9 One-touch fitting for 5/16" is available in units N11 One-touch fitting for 3/8" of 10 pieces

<!1 Fitting assembly>


(For cylinder port)

VVQ1000

51A

C8
Port size
C4 C6 C8 N3 N7 N9
One-touch fitting for 4 One-touch fitting for 6 One-touch fitting for 8 One-touch fitting for 5/32" One-touch fitting for 1/4" One-touch fitting for 5/16"

(For C kit)

AXT661
Wiring
3 4

1 3 AL

6
Lead wire length
Symbol L dimension (mm) 300 Nil 600 6 1000 10 1500 15 2000 20 2500 25 3000 30 5000 50
Note) Purchasing order is available in units of 10 pieces

For double (3-wire) For single (2-wire)

<!2 Gasket and screw assembly>

SQ2000 GS
Note) Part number for 10 pieces each of gaskets and screws.

2-3-123

Vous aimerez peut-être aussi