Académique Documents
Professionnel Documents
Culture Documents
HIS Heat Exchanger Training Apparatus (Model: HE 158C) is a bench type unit designed to allow students to get familiarised with different kinds of heat exchangers and to collect the necessary experimental data for the calculation of heat loss, heat transfer coefficient, log mean temperature difference, etc. Student will also be able to study the effect of flow rate on the heat transfer rate. Later, students may use this knowledge for designing complex industrial heat exchangers.
The HE 158C is supplied with four types of heat exchangers with two 50-L stainless steel sump tanks as the source for the hot and cold water circuit. The hot tank is fitted with a 11.5 kW immersion type heater which is protected against possible over heating. Each tank has a centrifugal pump to deliver the hot and cold water to the heat exchangers. The pumps are somehow protected from dry-run by level switch installed in each of the sump tanks. A temperature sensor and temperature controller are also provided to maintain a constant desired temperature inside the hot water tank.
The unit is supplied with all necessary instruments to measure the inlet and outlet temperatures of the hot and cold water as well as the flow rates of the hot and cold water and the pressure drops across the heat exchangers. Piping and fittings are made of stainless steel materials to prevent rust. The hot water and cold water circuits are properly insulated to minimize heat losses or heat gains between the tank and the heat exchangers.
SOLTEQ
Equipment for Engineering Education & Research Coil : O.D. = 9.53 mm I.D. = 7.05 mm Length = 5 m Material = stainless steel 316L Exchange area : 0.15 m2 (approx.) Plate Heat Exchanger No. of plates : 14 Plate material : stainless steel 316L Connections : 3/4 MPT Dimensions : 4.9 x 12.2 x 1.7 (W x L x D) Exchange area : 0.18 m2 Sump Tanks Capacity Material Ports Heater Pumps Type Capacity Head Electrical : : : :
EXPERIMENTAL CAPABILITIES Energy balance determination Temperature profiles in co-current and countercurrent flow Log mean temperature difference Heat transfer coefficient Flow rate effects on heat transfer rate Heat loss estimation Relationship between Nusselt (Nu) and Reynold (Re) numbers SPECIFICATIONS: Bench Epoxy coated mobile steel bench with lockable swivel castors. Shell & Tube Heat Exchanger Shell : I.D. = 82 mm Length = 500 mm Material = borosilicate glass Tubes : O.D. = 9.53 mm I.D. = 7.75 mm Length = 500 mm Tube count = 10 (single pass) Tube pitch = 18 mm (triangle) Baffle = 8 Baffle cut = 20% Material = stainless steel 316L Exchange area : 0.15 m2 (approx.) Concentric (Double Pipe) Heat Exchanger Shell : I.D. = 82 mm Length = 500 mm Material = borosilicate glass Tube : O.D. = 33.4 mm I.D. = 26.64 mm Length = 500 mm Material = stainless steel 316L Exchange area : 0.05 m2 (approx.) Spiral Heat Exchanger Shell : I.D. = 82 mm Length = 500 mm Material = borosilicate glass
Instrumentations Flow meters : 0 to 10 LPM (cold water) 0 to 10 LPM (hot water) Temperatures : 0 to 100 C Manometer : 0 to 50 cm of water Temperature sensor and controller
Control Panel Temperature controller for heater input to maintain the hot water temperature and prevent over heating. On/off buttons for pumps and heater. OPTIONAL ITEMS
- EI DIGITAL INSTRUMENTATIONS i) 8 units of digital indicators ii) 4 units of temperature sensors c/w transmitter iii) 2 units of electronic flow meters iv) 2 units of differential pressure transmitters
SOLTEQ
50 L Stainless steel Inlet/outlet/drain 11.5 kW for hot tank with temperature control Centrifugal, stainless steel 0 to 50 LPM 10 m 240VAC/1-phase/50 Hz : : : :
SOLTEQ
Equipment for Engineering Education & Research iv) Full experiment manuals REQUIREMENTS
A PC with latest Pentium Processor An electronic signal conditioning system Stand alone data acquisition modules Windows based data acquisition software Data Logging Signal Analysis Process Control Real-Time Display Tabulated Results Graph of Experimental Results AIDED LEARNING
Electrical supply: 415VAC/3-phase/50Hz Water supply Drainage points OVERALL DIMENSIONS Height : 1.50 m Width : 1.52 m Depth : 0.91 m MANUAL
i) Interactive multimedia features ii) Graphical simulation iii) Experiment results samples
The unit is supplied with Operating and Experiment Manuals in English giving full descriptions of the unit, summary of theory, experimental procedures and typical experimental results.
Shell & Tube Heat Exchanger with Variable Hot Water Flow Rate
1000
800
600
400
200
0 0 2,000 4,000 6,000 8,000 10,000 Tube side (hot water) Reynolds number Cold w ater at 20 LPM Cold w ater at 15 LPM
SOLTEQ
Cold w ater at 20 LPM Cold w ater at 15 LPM Cold w ater at 10 LPM 12,000 14,000 16,000
SOLTEQ
SOFTWARE & E - LEARNING Our range of teaching equipment can be complemented with our SOLDAS and SOLCAL software.
SOLDAS - Supervisory Control & Data Acquisition - Data Logging - Signal Analysis - Process Control - Real-Time Display - Tabulated Results - Graph of Experimental Results
SOLCAL - Computer Aided Learning - Multimedia Features - Interactive - Graphic Simulation - Experiment Result Samples - Full Experiment Manuals
AGENT:
No.3, Jalan TPK 2/4, Taman Perindustrian Kinrara, 47100 Puchong, Selangor Darul Ehsan, Malaysia. Tel. No. : +(603) 80758000 Fax. No. : +(603) 80755784
R&D Office : G-2A, Incubator 3, Technology Park Malaysia, Bukit Jalil, 57000 Kuala Lumpur, Malaysia. Tel. No. : +(603) 8996 0023 Email : solution@solution.com.my Web site : http//www.solution.com.my/
BUATAN MALAYSIA
MSC- Status
Company