Specifications 4 voltages / 3 Currents No of Channels (Neutral Amps measured as Vector sum of phase currents) Voltage (RMS AC+DC) Phase-phase

Range should be 10 V to 960 V Phase-neutral Range should be 6 V to 480 V Current Clamp Options 0.5 to 200 A 0.005 A to 5 A / 0.1 A to 100 A 3 A to 1,200 A 30 A to 6,500 A 10 A to 1,000 A ac / 10 A to 1,400 A dc Frequency range 40 Hz to 69 Hz Power values W, VA, VAr, PF, DPF, cos , tan Energies kWh, kVAh, kVArh Harmonics Should measure up to 50th order phase wise Should measure For Voltage & Current along with Phase THD angle Snap Shots Should store more than 8 pictures Flicker Should measure flickering and record to the instrument for Voltage & Current and should be able to record to the Unbalances instrument Memory Should be more than 2MB Min/Max recording for all instantaneous parameters Flexible recording Should allow to record selected parameters Multi-tasking Alarms Peak Vectorial Representation Waveform Display Display Electrical Safety Communication Interface Power Supply Battery backup Dimension approx not more than Weight should not be more than Should be able to log in selected parameters along with alarm capturing facility Option to select events for any instantaneous parameter with time duration choice should display Voltage & Current Peak Automatic should display 3 phase V&A wave forms in color including Neutral Colour VGA LCD screen, 320 x 240, diagonal 148 mm IEC 61010 1,000 V CAT III / 600 V CAT IV USB type Should be 230V external adaptor 8 hours or more 250 x 200 x 60mm 2 kG

Features Real-time display of wave forms (4 voltages and 4 currents) RMS voltage and currents per half-period Intuitive use Automatic recognition of the different types of current sensors Integration of all the DC components Measurement, calculation and display of the harmonics up to the 50th order, along with the phase information Calculation of Total Harmonic Distortion (THD) Display of Phasor diagram voltage & current on one screen Measurement of VA, W and VAr power values (total and per phase) Measurement of VAh, Wh and VArh energy values (total and per phase) Calculation of the K-Factor Calculation of the cos displacement power factor (DPF) and the power factor (PF) Flicker calculation Unbalance calculation (current and voltage) Monitoring of the electrical network with setting of alarms Back-up and recording of screenshots (image and data) Software for data recovery and real-time communication with a PC Recording and export onto PC Product support facilities Supplier must have In-house testing and calibration facilities Supplier must have In-house facility to provide quick and dependable after sales support (service) with trained technicians and service facility must be equipped with stock of all spares and components. Supplier should have engineers stationed at Coimbatore to render support and after sales training etc.,

Vous aimerez peut-être aussi