Académique Documents
Professionnel Documents
Culture Documents
Catalogue HY11-3500/UK
D1SE D1VW D1VW D1VW D1VW D1MW D3W D3W D3MW D31DW D41VW D81/91VW D111VW D1VP D3DP D4P D9P D11P D1DL D3DL D4L D9L
DIN / ISO 06 10 16 25 32 10 16 25 32 Seat valves, electrically operated Spool valves, electrically operated Standard, soft shift 8 Watt solenoid Inductive position control Explosion proof (conform to ATEX) For wash down applications Standard Inductive position control For wash down applications Standard and position control Highest ow Standard and position control Standard Standard and position control Standard Standard and position control Spool valves, hydraulically operated Spool valves, mechanically operated Accessories Plugs Actuator kits O-rings and seal kits Mounting patterns
2-3 2-7 2-15 2-21 2-27 2-31 2-37 2-47 2-53 2-59
2-75
2-87
2-97
content02.INDD CM_23.01.2008.1
2-1
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Notes
Catalogue HY11-3500/UK
content02.INDD CM_23.01.2008.1
2-2
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Catalogue HY11-3500/UK
Characteristics
The directional valve type D1SE is equipped with a wet pin armature solenoid, drain free tapered poppet valve and compatible with the standards DIN NG06, CETOP 03, and NFPA D03. Due to the 3/2 way design, port A is either connected with P or discharged in the tank. The neutral position (solenoid not activated) is taken automatically by a return spring. This position remains until the solenoid is energized. The valve poppet including activation lever and armature of the solenoid are located in the pressurized oil chamber of connection T. The valve poppet is designed such that there can be no differential area in its axial operational direction (opening, closing).Thus it is statically pressurebalanced so that the valve can be switched in both ow directions even under pressure. The unit has an all-steel design, the important functional inner parts are hardened, the poppet and seat are grinded.
Technical data
General Design Actuation Size Mounting interface Mounting position Ambient temperature [C] Weight [kg] Hydraulic Max. operating pressure P, A and T [bar] Fluid Fluid temperature [C] Viscosity permitted [cSt] / [mm/s] Viscosity recommended [cSt] / [mm/s] Filtration Flow max. [l/min] Static / Dynamic Step response [ms] [ms] Electrical characteristics Duty ratio Max. switching frequency [1/h] Protection class Code Supply voltage [V] Tolerance supply voltage [%] Current consumption [A] Power consumption [W] Solenoid connection Wiring min. [mm] Wiring length max. [m] Directional poppet valve Solenoid DIN NG6 / CETOP 03 / NFPA D03 DIN 24340 A6 / ISO 4401 / CETOP RP 121-H / NFPA D03 Unrestricted -25...+50, observe permissible duty cycle 1.5 350 Hydraulic oil in accordance with DIN 51524 / 51525 -25 ... +70 10...500 30...80 ISO 4406 (1999); 18/16/13 (meet NAS 1638: 7) 20 Energized: approx. 50 De-energized: approx. 60 See diagram 2000 IP65 in accordance with EN 60529 (plugged and mounted) K J U 12 V = 24 V = 98 V = 10 10 10 1.95 1.1 0.25 23.4 26.4 24.3 Connector as per EN 175301-803 3 x 1.5 recommended 50 recommended
With electrical connections the protective conductor (PE W) must be connected according to the relevant regulations.
D1SE_UK.INDD CM_10.03.2008.1
2-3
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Catalogue HY11-3500/UK
Ordering Code
S
Seat valve
E
Wet pin armature solenoid, anged Spool type
B
Style Seals Solenoid voltage
W
Connector as per EN 175301-803 without plug 1)
(not required for ordering)
2
Code 30
Design Series
Spool type
Code K J U 2) G 2)
2)
83
To be used with rectier plug when DC solenoids are used with AC input.
Code N V
1)
D1SE_UK.INDD CM_10.03.2008.1
2-4
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Catalogue HY11-3500/UK
Dimensions
Surface nish BK375 Subplates and manifolds see chapter 12. 4x M5x30 DIN 912 12.9 7.6 Nm 15% NBR: SK-D1SE-70 FPM: DK-D1SE-V70
The space necessary to remove the plug per EN 175301-803, design type AF is at least 15 mm. The torque for the screw M3 of the plug has to be 0.5 to 0.6 Nm.
D1SE_UK.INDD CM_10.03.2008.1
2-5
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Catalogue HY11-3500/UK
Notes
D1SE_UK.INDD CM_10.03.2008.1
2-6
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Catalogue HY11-3500/UK
Characteristics
The new NG06 directional control valve is available with both Parker (D1VW) and Denison (4D01) model codes. The new design provides high functional limits up to 80 l/min in combination with a very low, energy-saving pressure drop. A wide variety of spool options allows to design an unlimited number of hydraulic circuits. Versions with 8 watt coils, position control, Atex approval, surface protection and connector variants are shown in the following chapters.
Technical data
General Design Actuation Nominal size Mounting interface Mounting position Ambient temperature Weight Hydraulic Max. operating pressure Fluid Fluid temperature Viscosity permitted Viscosity recommended Filtration Flow max. Leakage at 50 bar Static / Dynamic Step response Electrical characteristics Duty ratio Max. switching frequency Protection class Supply voltage Tolerance supply voltage Current consumption hold Current consumption in rush Power consumption hold Power consumption in rush Solenoid connection Wiring min. Wiring length max. Directional spool valve Solenoid DIN NG06 / CETOP 03 / NFPA D03 DIN 24340 A6 / ISO 4401 / CETOP RP 121-H / NFPA D03 unrestricted, preferably horizontal [C] -25...+50 [kg] 1.5 (1 solenoid), 2.1 (2 solenoids) [bar] P, A B: 350; T: 210 (DC), T: 140 (AC) Hydraulic oil in accordance with DIN 51524 / 51525 [C] -25 ... +70 [cSt] / [mm/s] 2.8...400 [cSt] / [mm/s] 30...80 ISO 4406 (1999); 18/16/13 (meet NAS 1638: 7) [l/min] 80 [ml/min] Up to 10 per ow path, depending on spool see table response time 100% ED; CAUTION: coil temperature up to 150 C possible [1/h] 15000 IP 65 in accordance with EN 60529 (plugged and mounted) Code K J U G Y T [V] 110V at 50Hz/ 230V at 50Hz/ 12 V = 24 V = 98 V = 205 V = 120V at 60Hz 240V at 60Hz [%] 10 10 10 10 5 5 [A] 2.58 1.29 0.32 0.15 0.6 / 0.55 0.3 / 0.27 [A] 2.58 1.29 0.32 0.15 2.5 / 2.4 1.25 / 1.2 31 W 31 W 31 W 31 W 70 / 70 VA 70 / 70 VA 31 W 31 W 31 W 31 W 280 / 290 VA 280 / 290 VA Connector as per EN 175301-803, solenoid identication as per ISO 9461 (code W). [mm] 3 x 1.5 recommended [m] 50 recommended
With electrical connections the protective conductor (PE W) must be connected according to the relevant regulations.
D1VW-4D01_UK.INDD CM_10.03.2008.1
2-7
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Catalogue HY11-3500/UK
Ordering Code
W
Wet pin armature solenoid, threaded in tube Spool type Spool position Seals
Directional Size 3-chamber control DIN NG06 valve valve CETOP 03 NFPA D03 3 position spools Code Spool type a 0 b 001 002 003 004 005 006 007 008 1) 009 1) 010 011 014 015 016 021 022 031 032 034 035 061 081 082 102 204 1) 205 1) 2 position spools Code Spool type a b 020 026 030 083 1) 101 208
1)
Code N V
Code C Standard
3 position spools Spool position 3 positions. Spring offset in position 0. Operated in position a or b. Spool type 008,009, 204, 205 2 positions. Spring offset in position 0.
Operated in position a.
Operated in position b.
Operated in position b.
Operated in position a.
Code Standard B
A B
a
P
b
T
2 position spools Spool position Spool type 083 2 positions. Spring offset in position b. Operated in position a. 2 positions. Operated in position a or b. No centre or offset position. A B 2 positions. a b Spring offset in position a. P T Operated in position b.
D1VW-4D01_UK.INDD CM_10.03.2008.1
2-8
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Catalogue HY11-3500/UK
Ordering Code
W
Solenoid voltage Solenoid connector as per EN 175301-803, without plug
(other connectors are available for D1MW Series)
Solenoid option
Design series
Code K J U 2) G
2)
Voltage 12V = 24V = 98V = 205V = 110V 50Hz / 120V 60Hz 230V 50Hz / 240V 60Hz
Y T
2)
Code omit T S2
3)
Solenoid option Standard solenoid with manual override without manual override Soft shift orice size 0.5 mm. Soft shift orice size 0.75 mm.
S3 3)
3)
The Parker model code should be used for all new applications. Otherwise also refer to Denison model code.
2-9
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Catalogue HY11-3500/UK
Ordering Code
4D01
Directional control valve size DIN NG06 CETOP 03 Code 1 2 7
3
Body Control 3-chamber design Spool type
C
Design series Seals Solenoid voltage
Options
Control 1 solenoid 2 solenoids 2 solenoids and 2 pos. detents (only for spool types 11, 12, 51)
Code omit G3 3) 32
3)
Options Standard valve Soft shift with 0.75 mm orice in anchor tube Solenoid tube without manual override Solenoid voltage 12V = 24V = 98V = 205V =
DC only
3 position spools Code Spool type a 0 b 01 02 03 07 08 09 10 13 14 46 55 56 64 65 AR OT OX 2 position spools Code Spool type a b 11 12 51 52 71 81 1) 81 2)
1) 2)
W30 110V 50Hz/120V 60Hz W31 230V 50Hz/240V 60Hz Code 1 5 Code 01 02 3 position spools Spool position 3 positions. Spring centered to 0. 2 positions. Spring centered to 0. Energized to b. 2 positions. Spring centered to 0. Energized to a. 2 position spools Spool position 2 positions. Spring offset to b. Energized to a. 2 positions. Spring offset to a. Energized to b. 2 positions detent. Operated in a or b. No centre or spring offset position. Seals NBR FPM End cap for control 1 for controls 2 and 7
Code 03 05
06
Code 01
A B
a
P
b
T
The Denison model code is available for existing applications. For new applications we advise to refer to Parker model code.
02
09
D1VW-4D01_UK.INDD CM_10.03.2008.1
Start
Ordering Code
Index
Catalogue HY11-3500/UK
20
40
60
80 Flow [l/min]
Spool D1VW 001 002 003 004 005 006 007 010 011 014 015 016 020B 026B 030B 034 035 081 082 101B 102 61 83H 104 208 008 009 83B 204 205 Spool 021 022 55 56 81 81 4D01 03 01 10 08 13 46 BN 02 09 14 51 12 11 AR OT
P-B
P-A
P-A 1 12 7
P-B 1
Position 0 A-T 5 7 7
B-T 5 7 2
P-T 2
7 3 14 2 12
7 7
14 7
5 7
7 5
0X 71 52 07 64 65
5 3 3 P-A
5 2
8 14
6 14
P-B
A-T
B-T
P-T 9 7 7 5
A-B
A-B
D1VW-4D01_UK.INDD CM_10.03.2008.1
2-11
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Catalogue HY11-3500/UK
Shift Limits
The diagram below species the shift limits for valves with DC solenoids. Valves with spool position F or M can only be operated up to 70% of the limits. The specications apply to a viscosity of 40mm2/s and balanced ow
Pressure [bar]
Denison 03 01 10 08 13 46 07 BN 02 09 14 51 55 56 12 11 81 64 65 52
Pressure [bar]
001,002, 006
80
90
Flow [l/min]
016 020 021 022 026 030 081 082 001 F/M 204 205
Flow [l/min]
Pressure [bar]
001,002, 006
80
90
D1VW-4D01_UK.INDD CM_10.03.2008.1
Flow [l/min]
208
2-12
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Catalogue HY11-3500/UK
Response Times
Shift limit diagram - Soft shift
Supply pressure [bar]
350 300 250 200 150 100 50
002, 007, 010, 014, 026 008, 081, 082 011 003, 015 009 021, 022 006 005, 016
001 020
004
10
20
30
40
50
60
70 80 Flow [l/min]
Step response times were obtained under the following conditions: = 40 mm2/s at 50C with the valve operating at nominal pressure and ow. Published response times are nominal and may vary with spool, ow, pressure and temperature.
Acceleration for orice size 0.75, code S3 (archived against a valve without soft shift)
For even softer shifting, the proportional spools 081, 082, 101 and 102 can be used.
D1VW-4D01_UK.INDD CM_10.03.2008.1
2-13
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Catalogue HY11-3500/UK
Dimensions
Interface EN 175301-803, DC solenoid B, E, F / 01, 06 -style
9.5
93
22
22
69
C, D / 03, 09 -style
9.5
22
69
93
H, K, M / 02, 05 -style
9.5
69
22
5.5 127 152 46 46
93
4x M5x30 DIN 912 12.9
69.5 93.5
22
C, D / 03, 09 -style
9.5
22
5.5 84 211
The space necessary to remove the plug per EN 175301-803, design type AF is at least 15 mm. The torque for the screw M3 of the plug has to be 0.5 to 0.6 Nm.
D1VW-4D01_UK.INDD CM_10.03.2008.1
2-14
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
69.5 93.5
69.5 93.5
Characteristics
Catalogue HY11-3500/UK
The D1VW 8 Watt series is based on the standard D1VW design.The low watt, low current (<0.5 A) solenoid allows direct connection to a PLC or a bus knot. The valves are offered with standard solenoid connection (as per EN175301-803) and M12 x 1 connection. The version with M12 x 1 connection and LEDs are conform to the DESINA standard (DistributEd and Standardised INstAllation technology) for machine tools and manufacturing systems.
Technical data
General Design Actuation Size Mounting interface Mounting position Ambient temperature Weight Hydraulic Max. operating pressure Fluid Fluid temperature Viscosity permitted Viscosity recommended Filtration Flow max. Leakage at 50 bar Static / Dynamic Step response at 95% Electrical characteristics Duty ratio Max. switching frequency Protection class Supply voltage Tolerance supply voltage Current consumption Power consumption Solenoid connection Wiring min. Wiring length max.
D1VW 8W_UK.INDD CM_21.01.2008.1
Directional spool valve Solenoid DIN NG06 / CETOP 03 / NFPA D03 DIN 24340 A6 / ISO 4401 / CETOP RP 121-H / NFPA D03 unrestricted, preferably horizontal [C] -25...+50 [kg] 1.5 (1 solenoid), 2.1 (2 solenoids) [bar] P, A B: 350, T: 210 Hydraulic oil in accordance with DIN 51524 / 51525 [C] -25 ... +70 [cSt] / [mm/s] 2.8...400 [cSt] / [mm/s] 30...80 ISO 4406 (1999); 18/16/13 (meet NAS 1638: 7) [l/min] 45 [ml/min] Up to 10 per ow path, depending on spool [ms] Energized: 80...120; De-energized: 35...55 100% ED; CAUTION: coil temperature up to 70 C possible [1/h] 10000 IP 65 in accordance with EN 60529 (plugged and mounted) Code J [V] 24 V = [%] 10 [A] 0.33 [W] 8 Connector as per EN 175301-803, solenoid identication as per ISO 9461 (code W). Plug M12x1 on coil as per IEC 61076-2-101 (code D). [mm] 3 x 1.5 recommended [m] 50 recommended
With electrical connections the protective conductor (PE W) must be connected according to the relevant regulations.
2-15
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Catalogue HY11-3500/UK
Ordering Code
W
Wet pin solenoid Spool type Spool position Seals
2
001 002 003 004 005 006 007 008 1) 009 1) 010 011 014 015 016 076 078 081 082 102
Directional Size 3-chamber control DIN NG06 valve valve CETOP 03 NFPA D03 3 position spools Code Spool type a 0 b
Code N V
Code C Standard E
3 position spools all 3 position spools 3 positions. Spring offset in position 0. Operated in position a or b. Spool type 008, 009 2 positions. Spring offset in position 0.
Operated in position a.
Operated in position b.
Operated in position b.
Operated in position a.
Code B
A B
a
P
b
T
D 2)
H
2)
2 position spools Spool position 2 positions. Spring offset in position b. Operated in position a. 2 positions. Operated in position a or b. No centre or offset position. 2 positions. Spring offset in position a. Operated in position b.
2-16
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Ordering Code
Catalogue HY11-3500/UK
L
Electrical option Accessories
(not required for ordering)
Design series
2
Accessories
Code D 3) W 3)
3)
Connection M12x1 on coil as per IEC 61076-2-101 Connector as per EN 175301-803, without plug
Code omit 5
Standard valve (in combination with solenoid connection W) In combination with solenoid connection D
Solenoid identication acc. to ISO 9461 Code omit Electrical option Standard valve (in combination with solenoid connection W) Surge diode with LED, max. voltage peak 50V (only available in combination with solenoid conn. D)
Further spool types on request. To get a DESINA valve, order the combination: JDLJ5
2-17
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Catalogue HY11-3500/UK
Spool 001 002 003 004 005 006 007 010 011 014 015 016 020 026 030 008 009
P->A 2 7 7 2 P->A
P->B 2 7 2 7 P->B
P->T 2 4 4 P->T 7 3
A->B 1 8 7 A-> B
2-18
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Catalogue HY11-3500/UK
020B/H
150
004
50
026
10
15
20
25
30
35
40 45 Flow [l/min]
M12 pin assignment DESINA design (code JDLJ5), Pins 1 and 2 connected
2-19
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Dimensions
Catalogue HY11-3500/UK
9.5
2
22
87.3 5.5 156 46
69
22
5.5
130.7 156
46
Style C, D
A
9.5
22
87.3
5.5 218
46
69
93
9.5
98
9.5
98
71
22
22
87.3
5.5 156
5.5 46
130.7 156
46
Style C, D
9.5
98
22
87.3
5.5 218
46
Surface nish BK375 4x M5x30 DIN 912 12.9 7.6 Nm 15% NBR: SK-D1VW-N-91 FPM: SK-D1VW-V-91
The space necessary to remove the plug per EN 175301-803, design type AF is at least 15 mm. The torque for the screw M3 of the plug has to be 0.5 to 0.6 Nm.
D1VW 8W_UK.INDD CM_21.01.2008.1
71
2-20
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
71
69
93
Catalogue HY11-3500/UK
Characteristics
The direct operated 4/2 directional valves with inductive position control are typically used in safety relevant applications. The start or end position can be monitored. The position control is only available for single solenoid valves. The fail-safe position of the directional valve during power failure is the spring offset position.
Attention The adjustment of the position control is factory set and sealed. Replacement and repairs can only be undertaken by the manufacturer.
Technical data
General Design Actuation Size Mounting interface Mounting position Ambient temperature Weight Hydraulic Max. operating pressure Fluid Fluid temperature Viscosity permitted Viscosity recommended Filtration Flow max. Leakage at 50 bar Static / Dynamic Step response at 95% Electrical characteristics Duty ratio Max. switching frequency Protection class Supply voltage Tolerance supply voltage Current consumption Power consumption Solenoid connection Wiring min. Wiring length max. Directional spool valve Solenoid DIN NG06 / CETOP 03 / NFPA D03 DIN 24340 A6 / ISO 4401 / CETOP RP 121-H / NFPA D03 unrestricted, preferably horizontal [C] 0...+50 [kg] 1.8 (1 solenoid) [bar] P, A B: 350 ; T: 210 Hydraulic oil in accordance with DIN 51524 / 51525 [C] -25 ... +70 [cSt] / [mm/s] 2.8...400 [cSt] / [mm/s] 30...80 ISO 4406 (1999); 18/16/13 (meet NAS 1638: 7) [l/min] 80 [ml/min] Up to 10 per ow path, depending on spool [ms] Energized: 32 ; De-energized: 40 100% ED; CAUTION: coil temperature up to 150 C possible [1/h] 15000 IP 65 in accordance with EN 60529 (plugged and mounted) Code K J U [V] 12 V = 24 V = 98 V = [%] 10 10 10 [A] 2.5 1.25 0.31 [W] 30 30 30 Connector as per EN 175301-803, solenoid identication as per ISO 9461. [mm] 3 x 1.5 recommended [m] 50 recommended
G 205 V = 10 0.15 30
With electrical connections the protective conductor (PE W) must be connected according to the relevant regulations.
D1VW poscontr_UK.INDD CM_21.01.2008.1
2-21
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Catalogue HY11-3500/UK
Ordering Code
W
Wet pin solenoid Spool type Spool position Seals
2
001 002 003 1) 004 005 015 2) 016 076 078
Directional Size 3-chamber control DIN NG06 valve valve CETOP 03 NFPA D03 3 position spools Code Spool type a 0 b
Code N V 3 position spools Code E Operated in position a. F Spring offset in position b. K Standard
2 positions. Spring offset in position 0. 2 positions. Operated in position 0. 2 positions. Spring offset in position 0. 2 positions. Operated in position 0.
Only available for spool position E and F. Only available for spool position K and M.
Code B
2)
2 position spools Spool position 2 positions. Spring offset in position b. Operated in position a. 2 positions. Spring offset in position a. Operated in position b.
2-22
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Catalogue HY11-3500/UK
Ordering Code
W
Solenoid voltage Connector as per EN 175301-803, without plug Manual override option Position control
(not required for ordering)
Design series
Code K J U 3) G 3)
3)
Position control End position monitored side B Start position monitored side B End position monitored side A Start position monitored side A Manual override Standard valve with manual override without manual override
To be used with rectier plug when DC solenoids are used with AC input.
K, M, H (Solenoid on b-side)
Code omit T 4)
4)
For hydraulic presses according to the safety regulations EN 693, solenoid option T (without manual override) and accessories I4N or I5N (start position monitored) are required.
2-23
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Catalogue HY11-3500/UK
Position Control
Denitions Start position monitored: The valve is de-energized. The inductive switch gives a signal at the moment when the spool leaves the spring offset position (below 15% spool stroke). The switch can only be located on the opposite side of the solenoid for direct operated valves.
End position monitored: The inductive switch gives a signal before the end position is reached (above 85% spool stroke).
2-24
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Catalogue HY11-3500/UK
Performance Curves
The ow curve diagram shows the ow versus pressure drop curves for all spool types.The relevant curve number
Spool 001 002 003 004 005 015 016 020 B 026 B 030 B Position b P->A B->T 2 2 1 4 3 4 2 3 2 2 3 6 2 2 4 4 4 2 3 Position a P->B A->T 2 2 1 4 3 6 2 3 2 2 3 4 2 2 2 3 4 1 2
20
40
60
80 Flow [l/min]
Shift limit diagram The diagram below species the shift limits. Valves with spool position F or M can only be operated up to 70% of the limits. The specications apply to a viscosity 40mm2/s and balanced ow conditions.The shift limits can
Supply pressure [bar]
350 300 250 200 150 100 50 0 0 10 20 30 40
be considerably lower at unbalanced ow conditions. To avoid ow rates beyond the shift limits, a plug-in orice can be inserted in the P-port.
026
50
60
70
80
90
Flow [l/min]
2-25
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Catalogue HY11-3500/UK
Dimensions
2
22
91.4
9.5
92
5.5 259.4
46
H, K, M -style
50 9.5
5.5 259.4
22
134.4
46
* Delivery includes plug M12 x 1 (see accessories, plug M12x1; order no.: 5004109).
Surface nish BK375 4x M5x30 DIN 912 12.9 7.6 Nm 15% NBR: SK-D1VW-N-91 FPM: SK-D1VW-V-91
The space necessary to remove the plug per EN 175301-803, design type AF is at least 15 mm. The torque for the screw M3 of the plug has to be 0.5 to 0.6 Nm.
Attention The adjustment of the position control is factory set and sealed. Replacement and repairs can only be undertaken by the manufacturer.
2-26
71
92
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Characteristics
Catalogue HY11-3500/UK
The D1VW with explosion proof solenoids is based on the standard D1VW series. The specic solenoid design allows the use in hazardous environments. The explosion proof class is EEx me II T4 for use in zone 1. All explosion proof solenoids are DC design. For AC (code P and N) the input voltage is internally rectied.
Technical data
General Design Actuation Size Mounting interface Mounting position Ambient temperature Weight Hydraulic Max. operating pressure Fluid Fluid temperature Viscosity permitted Viscosity recommended Filtration Flow max. Leakage at 50 bar Static / Dynamic Step response at 95% Electrical characteristics Duty ratio Max. switching frequency Protection class Supply voltage / ripple Tolerance supply voltage Current consumption Power consumption Solenoid connection Wiring min. Wiring length max. Directional spool valve Solenoid DIN NG06 / CETOP 03 / NFPA D03 DIN 24340 A6 / ISO 4401 / CETOP RP 121-H / NFPA D03 unrestricted, preferably horizontal [C] -25...+50 [kg] 1.8 (1 solenoid), 2.7 (2 solenoids) [bar] P, A B: 350 T: 210 Hydraulic oil in accordance with DIN 51524 / 51525 [C] -25 ... +60 [cSt] / [mm/s] 2.8...400 [cSt] / [mm/s] 30...80 ISO 4406 (1999); 18/16/13 (meet NAS 1638: 7) [l/min] 80 [ml/min] Up to 10 per ow path, depending on spool [ms] Energized: 32 (DC) De-energized: 40 (DC) 100% ED; CAUTION: coil temperature up to 130 C possible [1/h] 15000 , EEx me II T4, IP66 J Y T 24 V = 110/50Hz / 120/60Hz 230/50Hz / 240/60Hz 10 5 5 1.25 0.32 0.15 30 30 30 Box with M20x1.5 entry for cable glands. Solenoid identication as per ISO 9461. [mm] 3 x 1.5 recommended [m] 50 recommended Code [V] [%] [A] [W]
With electrical connections the protective conductor (PE W) must be connected according to the relevant regulations.
D1VW expl_UK.INDD CM_21.01.2008.1
2-27
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Ordering Code
Catalogue HY11-3500/UK
W
Wet pin solenoid Spool type Spool position Seals
2
001 002 003 004 005 006 007 008
1)
Directional Size 3-chamber control DIN NG06 valve valve CETOP 03 NFPA D03 3 position spools Code Spool type a 0 b
Solenoid Connection: Solenoid Design voltage Explosion options: series Explosion (not required proof for ordering) proof with cable EEx me II glands
Code J Y T
Voltage 24V= 110V 50Hz 120V 60Hz 230V 50Hz 240V 60Hz Seals NBR FPM
Code N V
009 1) 010 011 014 015 016 021 022 031 032 076 078 081 082 102 2 position spools Code Spool type a b 020 026 030 101
1)
Code C Standard E
3 position spools all 3 position spools 3 positions. Spring offset in position 0. Operated in position a or b. Spool type 008, 009 2 positions. Spring offset in position 0.
Operated in position a.
Operated in position b.
Operated in position b.
Operated in position a.
Code B
A B
a
P
b
T
2 position spools Spool position 2 positions. Spring offset in position b. Operated in position a. 2 positions. Operated in position a or b. No centre or offset position. 2 positions. Spring offset in position a. Operated in position b.
2-28
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Catalogue HY11-3500/UK
021 022
A->T
B->T
P->T 6 7 7 P->T 8 9
A->B 1 9 9 A-> B
A->B 3
1)
2-29
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Catalogue HY11-3500/UK
The diagram below species the shift limits for valves with DC solenoids. Valves with spool position F or M can only be operated up to 70% of the limits. The specications apply to a viscosity 40mm2/s and balanced ow
300
001
003, 015
009
250
004 011
006
200
150
030 007,014
100
008
Dimensions B, E, F -style
H, K, M -style
C, D -style
NBR 4x M5x30 DIN 912 12.9 7.6 Nm 15% NBR: SK-D1VW-N-91 FPM: SK-D1VW-V-91
2-30
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Characteristics
Catalogue HY11-3500/UK
The new D1MW is based on the D1VW series of directional control valves size NG06, but offers additional corrosion protection of the valve body, the solenoid coil and the anchor tube as well as the typical solenoid connections for the mobile market such as AMP Junior Timer and DP4 Deutsch. Technical features High corrosion protection (optional) Solenoid connection: - Standard (as per EN175301-803) - AMP Junior Timer - DP4 2-pin Deutsch Robust design for rough applications Extended manual override with rubber cover (optional)
2
With AMP Junior Timer
Technical data
General Design Actuation Size Mounting interface Mounting position Ambient temperature Weight Hydraulic Max. operating pressure Fluid Fluid temperature Viscosity permitted Viscosity recommended Filtration Flow max. Leakage at 50 bar Static / Dynamic Step response at 95% Electrical characteristics Duty ratio Max. switching frequency Protection class Supply voltage Tolerance supply voltage Current consumption hold Power consumption hold Solenoid connection Wiring min. Wiring length max.
D1MW_UK.INDD CM_21.01.2008.1
Directional spool valve Solenoid DIN NG06 / CETOP 03 / NFPA D03 DIN 24340 A6 / ISO 4401 / CETOP RP 121-H / NFPA D03 Unrestricted, preferably horizontal [C] -25...+50 [kg] 1.5 (1 solenoid), 2.1 (2 solenoids) [bar] P, A B: 350; T: 210 Hydraulic oil in accordance with DIN 51524 / 51525 [C] -25 ... +70 [cSt] / [mm/s] 2.8...400 [cSt] / [mm/s] 30...80 ISO 4406 (1999); 18/16/13 (meet NAS 1638: 7) [l/min] 80 [ml/min] Up to 10 per ow path, depending on spool [ms] Energized: 32 De-energized: 40 100% ED; CAUTION: coil temperature up to 150 C possible [1/h] 15000 IP 65 in accordance with EN 60529 (plugged and mounted) Code K J [V] 12 V = 24 V = [%] 10 10 [A] 2.5 1.25 [W] 30 30 Connector as per EN 175301-803 (code W), AMP Junior Timer (code A), DP4 2-pin Deutsch connector (code J). Solenoid identication as per ISO 9461. [mm] 3 x 1.5 recommended [m] 50 recommended
With electrical connections the protective conductor (PE W) must be connected according to the relevant regulations.
2-31
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Ordering Code
Catalogue HY11-3500/UK
D
Directional control valve
W
Spool type Spool position
N
NBR Seal
2
001 002 004 006 008 1) 011 021 022 081 082
Wet pin 3-chamber Size armature valve for DIN NG06 CETOP 03 mobile and solenoid, threaded marine NFPA D03 applications in tube
3 position spools Code Spool type a 0 b Code C Standard E 3 position spools all 3 position spools 3 positions. Spring offset in position 0. Operated in position a or b. Spool type 008 2 positions. Spring offset in position 0.
Operated in position a.
Operated in position b.
Operated in position b.
Operated in position a.
Code B
A B
a
P
b
T
2 position spools Spool position 2 positions. Spring offset in position b. Operated in position a. 2 positions. Operated in position a or b. No centre or offset position. 2 positions. Spring offset in position a. Operated in position b.
D1MW_UK.INDD CM_21.01.2008.1
2-32
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Ordering Code
Catalogue HY11-3500/UK
Solenoid voltage
Connection
Solenoid options
Surface protection
Design series
2
Code Surface protection Standard, only for conomit nection J and A Anti corrosion coating acc. to DIN 50021SS for extreme conditions. For all connection options
Code K J Code W 2) J 2) A 2)
2)
Voltage 12V = 24V = Connection Connector as per EN 175301-803 Connector Deutsch DP4 2-pin 2-pin AMP Junior Timer
1P
Code omit T W
Solenoid option Standard solenoid without manual override extended manual override with rubber cover
D1MW_UK.INDD CM_21.01.2008.1
2-33
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Catalogue HY11-3500/UK
Spool 001 002 004 006 011 020 030 081 082 008
021 022
Position b P ->A B->T 3 1 2 1 4 1 2 4 6 2 5 3 3 1 10 10 10 10 P->B A->T 2 2 Position b P->A P->B 3 3 P->A B->T 6 1
P->B 2 7 P->B
A->T
B->T
P->T 2 P->T 8
A->B 1 9 7 A-> B
A->B 3
1)
D1MW_UK.INDD CM_21.01.2008.1
2-34
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Shift Limits
Catalogue HY11-3500/UK
The diagram below species the shift limits. Valves with spool position F or M can only be operated up to 70% of the limits. The specications apply to a viscosity 40mm2/s and balanced ow conditions.The shift limits can
350
021, 022
2
001 020
300
006
250
081, 082 011
200
150
030
004
100
008
50
002
0 0
10
20
30
40
50
60
70
80 Flow [l/min]
D1MW_UK.INDD CM_21.01.2008.1
2-35
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Dimensions
Catalogue HY11-3500/UK
2
22
91.4 5.5 46 162 176 (manual override with rubber cover)
93
69
22
5.5
46
C and D -style
9.5
22
91.4
5.5
46
Dimensions with 2pin AMP Junior Timer Connector (only C and D -style shown)
9.5
22
91.4
5.5
226 254 (manual override with rubber cover)
46
Dimensions with Deutsch DP4 2pin Connector (only C and D -style shown)
9.5
22
91.4
5.5
226 254 (manual override with rubber cover)
46
Surface nish BK375 4x M5x30 DIN 912 12.9 7.6 Nm 15% NBR: SK-D1VW-N-91 FPM: SK-D1VW-V-91
D1MW_UK.INDD CM_21.01.2008.1
The space necessary to remove the plug per EN 175301-803, design type AF is at least 15 mm. The torque for the screw M3 of the plug has to be 0.5 to 0.6 Nm.
2-36
63.5 65.5
58 71
69
93
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
69
93
Characteristics
Catalogue HY11-3500/UK
The direct operated directional control valve size NG10 is available with both Parker (series D3W) and Denison (series 4D02) model codes. Both series are available with a soft shift option for smooth operation. An additional orice in the solenoid anchor dampens the shifting time for D3W. For the 4D02 the orice is located in the valve body.
Technical data
General Design Actuation Size Mounting interface Mounting position Ambient temperature Weight Hydraulic Max. operating pressure Fluid Fluid temperature Viscosity permitted Viscosity recommended Filtration Flow max. Leakage at 50 bar Static / Dynamic Step response Electrical characteristics Duty ratio Max. switching frequency Protection class Directional spool valve Solenoid DIN NG10 / CETOP 05 / NFPA D05 DIN 24340 A10 / ISO 4401 / CETOP RP 121-H / NFPA D05 unrestricted, preferably horizontal [C] -25...+50 [kg] 4.8 (1 solenoid), 6.3 (2 solenoids) [bar] P, A B: 350; T: 210 (DC), 105 (AC), 210 (AC Code H) Hydraulic oil in accordance with DIN 51524 / 51525 [C] -25 ... +70 [cSt] / [mm/s] 2.8...400 [cSt] / [mm/s] 30...80 ISO 4406 (1999); 18/16/13 (meet NAS 1638: 7) [l/min] 150 (DC); 115 (AC) [ml/min] Up to 20 per ow path, depending on spool see table response time 100% ED; CAUTION: coil temperature up to 150 C possible [1/h] 10000 IP 65 in accordance with EN 60529 (plugged and mounted) Code K J U G
Y T 110V at 50Hz/ 230V at 50Hz/ Supply voltage / ripple [V] 12 V = 24 V = 98 V = 205 V = 120V at 60Hz 240V at 60Hz Tolerance supply voltage [%] 10 10 10 10 5 5 Current consumption hold [A] 3 1.5 0.37 0.18 0.8 / 0.72 0.4 / 0.36 Current consumption in rush [A] 3 1.5 0.37 0.18 3.41 / 3.31 1.75 / 1.7 Power consumption hold [W] 36 36 36 36 88 / 86 88 / 86 Power consumption in rush [W] 36 36 36 36 375 / 397 385 / 408 Solenoid connection Connector as per EN 175301-803, solenoid identication as per ISO 9461. Wiring min. [mm] 3 x 1.5 recommended Wiring length max. [m] 50 recommended With electrical connections the protective conductor (PE W) must be connected according to the relevant regulations.
D3W stand_UK.INDD CM_21.01.2008.1
2-37
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Ordering Code
Catalogue HY11-3500/UK
W
Wet pin solenoid Spool type Spool position Seals
2
1 2 3 4 5 6 7 8 1) 9 1) 10 2) 11 12 14 15 16 21 2) 22 2) 31 2) 32 2) 81 2) 82 2) 102 2)
Code N V
Code C Standard E
3 position spools all 3 position spools 3 positions. Spring offset in position 0. Operated in position a or b. Spool type 8 and 9 2 positions. Spring offset in position 0.
Operated in position a.
Operated in position b.
Operated in position b.
Operated in position a.
Code B
A B
a
P
b
T
2 position spools Spool position 2 positions. Spring offset in position b. Operated in position a. 2 positions. Operated in position a or b. No centre or offset position. 2 positions. Spring offset in position a. Operated in position b.
2)
2-38
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Ordering Code
Catalogue HY11-3500/UK
W
Solenoid voltage Connector Solenoid option as per EN 175301-803, without plug
(Please order plug separately)
Shift response
Design series
2
Code omit S4 4) S7 4)
4)
Code K J U 3) G 3) Y T
3)
Solenoid voltage 12V = 24V = 98V = 205V = 110V 50Hz / 120V 60Hz 230V 50Hz / 240V 60Hz
Shift response Standard response orice diameter 1.0 mm orice diameter 1.5 mm
Only for DC
To be used with retier plug when DC solenoids are used with AC input.
Code omit H T
Solenoid option Standard solenoid with manual override High pressure solenoid tube for AC. Tank pressure up to 210bar without manual override
The Parker model code should be used for all new applications. Otherwise also refer to Denison model code.
2-39
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Ordering Code
Catalogue HY11-3500/UK
4D02
Directional control valve size DIN NG10 CETOP 05 NFPA D05
C
Design series
Code 3 D
Body Standard 3-chamber 5-chamber for soft-shift (G3) Control 1 solenoid 2 solenoids 2 solenoids and 2 pos. detent (only for spool types 11 and 51) 05 06 Code 03
Code 1 2 7
3 positions. Spring centered to 0. 2 positions. Spring centered energized to b. 2 positions. Spring centered energized to a. 2 position spools Spool position 2 positions. Spring offset to b energized to a. 2 positions. Spring offset to a energized to b. 2 positions detent. Operated in a or b. No centre or spring offset position.
3 position spools Code Spool type a 0 b 01 02 03 07 08 09 10 46 55 56 2 position spools Code Spool type a b 11 12 51
Code 01
A B
a
P
b
T
02
09
2-40
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Ordering Code
Catalogue HY11-3500/UK
2
Code 1 5 Code G0R G0Q GAR * GAG * W30 W31 Seals NBR FPM Solenoid voltage 12V = 24V = 98V = 205V = 110V 50Hz / 120V 60Hz 230V 50Hz / 240V 60Hz
* To be used with retier plug when DC solenoids are used with AC input.
Code
Options
Solenoid connector as per omit EN 175301-803 without plug. With manual override G3 32 Soft shift with orice in body (for DC and body D only) Without manual override
The Denison model code is available for existing applications. For new applications we advise to refer to Parker model code.
2-41
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Catalogue HY11-3500/UK
21 22
55 56
P->B 3 6 4 7 5 P->B
P->T 5 6 8 6 P->T 6 6
A->B 1 5 6 8 A->B
A->B 6
2-42
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Catalogue HY11-3500/UK
Shift Limits
The diagram below species the shift limits for valves with DC and AC solenoids. Valves with spool position F or M can only be operated up to 70% of the limits. The specications apply to a viscosity 35mm2/s and balShift limits, DC voltage *
Measured at 90% Unom and warm solenoids. * For 4D02 spool code see ow curve table.
D3W stand_UK.INDD CM_21.01.2008.1
2-43
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Catalogue HY11-3500/UK
Step response times were obtained under the following conditions: = 35 mm2/s at 50C with the valve operating at 175 bar and 65 l/min. Published response times are nominal and may vary with spool, ow, pressure and temperature. * For AC input and soft shift use rectier plug.
Acceleration for different orice sizes (archived against a valve without soft shift)
Orice in anchor *
* Note: For 4D02 the orice is located in the Z-channel of the valve body. For even softer shifting, the proportional spools 81, 82, 101 and 102 can be used.
D3W stand_UK.INDD CM_21.01.2008.1
2-44
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Dimensions
Catalogue HY11-3500/UK
C, D -style
H, K, M -style
C, D -style
Surface nish BK385 4x M6x40 DIN 912 12.9 13.2 Nm 15% NBR: SK-D3W-30 FPM: SK-D3W-V30
The space necessary to remove the plug per EN 175301-803, design type AF is at least 15 mm. The torque for the screw M3 of the plug has to be 0.5 to 0.6 Nm.
D3W stand_UK.INDD CM_21.01.2008.1
2-45
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Notes
Catalogue HY11-3500/UK
2-46
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Characteristics
Catalogue HY11-3500/UK
The 4/2 directional valves operated directly by solenoids with inductive position control are used as monitoring valves. The start or end position can be monitored. The position control is only available for single solenoid valves. The fail-safe position of the directional valve during power failure is the spring offset position.
Attention The adjustment of the position control is factory set and sealed. Replacement and repairs can only be undertaken by the manufacturer.
Technical data
General Design Actuation Size Mounting interface Mounting position Ambient temperature Weight Hydraulic Max. operating pressure Fluid Fluid temperature Viscosity permitted Viscosity recommended Filtration Flow max. Leakage at 50 bar Static / Dynamic Step response at 95% Electrical characteristics Duty ratio Max. switching frequency Protection class Supply voltage / ripple Tolerance supply voltage Current consumption hold Power consumption hold Solenoid connection Wiring min. Wiring length max. Directional spool valve Solenoid DIN NG10 / CETOP 05 / NFPA D05 DIN 24340 A10 / ISO 4401 / CETOP RP 121-H / NFPA D05 unrestricted, preferably horizontal [C] 0...+50 [kg] 5.2 [bar] P, A, B: 350; T: 210 Hydraulic oil in accordance with DIN 51524 / 51525 [C] 0 ... +70 [cSt] / [mm/s] 2.8...400 [cSt] / [mm/s] 30...80 ISO 4406 (1999); 18/16/13 (meet NAS 1638: 7) [l/min] 150 [ml/min] Up to 20 per ow path, depending on spool Energized: 105; De-energized: 85 100% ED; CAUTION: coil temperature up to 150 C possible [1/h] 10000 IP 65 in accordance with EN 60529 (plugged and mounted) Code K J U G [V] 12 V = 24 V = 98 V = 205 V = [%] 10 10 10 10 [A] 3 1.5 0.37 0.18 [W] 36 36 36 36 Connector as per EN 175301-803, solenoid identication as per ISO 9461. [mm] 3 x 1.5 recommended [m] 50 recommended
With electrical connections the protective conductor (PE W) must be connected according to the relevant regulations.
D3W poscontr_UK.INDD CM_22.01.2008.1
2-47
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Ordering Code
Catalogue HY11-3500/UK
W
Wet pin solenoid Spool type Spool position Seals
2
1 2 3 1) 4 5
2)
Code N V Code E
15 2) 16
1)
21 1) 22 2)
3 position spools 2 positions. Spring offset in position 0. Operated in position a. 2 positions. Spring offset in position b. Operated in position 0. 2 positions. Spring offset in position 0. Operated in position b. 2 positions. Spring offset in position a. Operated in position 0. 2 position spools Spool position 2 positions. Spring offset in position b. Operated in position a. 2 positions. Spring offset in position a. Operated in position b.
Code B
2-48
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Ordering Code
Catalogue HY11-3500/UK
W
Solenoid voltage Connector Manual as per override EN 175301-803, option without plug
(Please order plug separately)
N
Position control Inductive Design position series control with (not required CE-code for ordering)
2
Position control End position monitored side B Start position monitored side B End position monitored side A Start position monitored side A
Code K J U 3) G 3)
3)
Code I2 I5 4) I1 I4 4)
For alternating current use plug with rectier. Please order rectier plug separately.
K, M, H (Solenoid on b-side)
Code omit T 4)
4)
For hydraulic presses according to the safety regulations EN 693, solenoid option T (without manual override) and accessories I4 or I5 (start position monitored) are required.
2-49
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Position Control
Catalogue HY11-3500/UK
1
3
+Vs 0V
ASEW001D10
0V
Denitions Start position monitored: The valve is de-energized. The inductive switch gives a signal at the moment when the spool leaves the spring offset position (below 15% spool stroke). The switch can only be located on the opposite side of the solenoid for direct operated valves.
End position monitored: The inductive switch gives a signal before the end position is reached (above 85% spool stroke).
2-50
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Performance Curves
The ow curve diagram shows the ow versus pressure drop curves for all spool types.The relevant curve number
Spool 1 2 3 4 5 15 16 20 26 30 Position b P->A B->T 4 3 4 1 4 3 4 2 5 3 4 3 4 4 2 Position b P->A P->B 5 4 P->A B->T Position a P->B A->T 4 3 4 1 4 2 5 3 4 3 4 3 4 4 2 A->B 6 P->B P->A 4
Catalogue HY11-3500/UK
21 22
A->B 6
Shift limit diagram The diagram below species the shift limits. Valves with spool position F or M can only be operated up to 70% of the limits. The specications apply to a viscosity 35mm2/s and balanced ow conditions.The shift limits can
be considerably lower at unbalanced ow conditions. To avoid ow rates beyond the shift limits, a plug-in orice can be inserted in the P-port.
2-51
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Dimensions
Catalogue HY11-3500/UK
H, K, M -style
* Delivery includes plug M12 x 1 (see accessories, plug M12x1; order no.: 5004109).
Surface nish BK385 4x M6x40 DIN 912 12.9 13.2 Nm 15% NBR: SK-D3W-30 FPM: SK-D3W-V30
The space necessary to remove the plug per EN 175301-803, design type AF is at least 15 mm. The torque for the screw M3 of the plug has to be 0.5 to 0.6 Nm.
Attention The adjustment of the position control is factory set and sealed. Replacement and repairs can only be undertaken by the manufacturer.
2-52
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Characteristics
Catalogue HY11-3500/UK
The D3MW is a solenoid operated directional control valve size NG10 in 3-chamber design. It is direct operated by wet pin solenoids. The D3MW is designed for mobile and marine applications. It is based on the D3W series, but offers additional corrosion protection of the valve body, the solenoid coil and the anchor tube as well as the typical solenoid connections for the mobile market such as AMP Junior Timer. Technical features: High corrosion protection Solenoid connection: - Standard (as per EN175301-803) - AMP Junior Timer Robust design for rough applications
Technical data
General Design Actuation Size Mounting interface Mounting position Ambient temperature Weight Hydraulic Max. operating pressure Fluid Fluid temperature Viscosity permitted Viscosity recommended Filtration Flow max. Leakage at 50 bar Static / Dynamic Step response at 95% Electrical characteristics Duty ratio Max. switching frequency Protection class Supply voltage / ripple Tolerance supply voltage Current consumption Power consumption Solenoid connection Wiring min. Wiring length max. Directional spool valve Solenoid DIN NG10 / CETOP 05 / NFPA D05 DIN 24340 A10 / ISO 4401 / CETOP RP 121-H / NFPA D05 unrestricted, preferably horizontal [C] -25...+50 [kg] 4.8 (1 solenoid), 6.3 (2 solenoids) [bar] P, A B: 350; T: 210 Hydraulic oil in accordance with DIN 51524 / 51525 [C] -25 ... +70 [cSt] / [mm/s] 2.8...400 [cSt] / [mm/s] 30...80 ISO 4406 (1999); 18/16/13 (meet NAS 1638: 7) [l/min] 150 [ml/min] Up to 20 per ow path, depending on spool [ms] Energized: 105 De-energized: 85 100% ED; CAUTION: coil temperature up to 150 C possible [1/h] 10000 IP 65 in accordance with EN60529 (plugged and mounted) Code K J [V] 12 V = 24 V = [%] 10 10 [A] 3 1.5 [W] 36 36 Connector as per EN 175301-803, AMP Junior Timer, Solenoid ident. as per ISO 9461. [mm] 3 x 1.5 recommended [m] 50 recommended
With electrical connections the protective conductor (PE W) must be connected according to the relevant regulations.
D3MW_UK.INDD CM_22.01.2008.1
2-53
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Ordering Code
Catalogue HY11-3500/UK
W
Spool type Spool position
N
NBR Seal
2
1 2 4 6 8
1)
Directional 3-chamber Wet pin Size control solenoid DIN NG 10 valve for valve CETOP 05 mobile and marine NFPA D05 applications 3 position spools Code Spool type a 0 b
Code C Standard E
3 position spools all 3 position spools 3 positions. Spring offset in position 0. Operated in position a or b. Spool type 8 and 9 2 positions. Spring offset in position 0.
Operated in position a.
Operated in position b.
Operated in position b.
Operated in position a.
Code B
A B
a
P
b
T
2 position spools Spool position 2 positions. Spring offset in position b. Operated in position a. 2 positions. Operated in position a or b. No centre or offset position. 2 positions. Spring offset in position a. Operated in position b.
D3MW_UK.INDD CM_22.01.2008.1
2-54
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Ordering Code
Catalogue HY11-3500/UK
1P
Solenoid voltage Connection Solenoid options Anti corrosion coating acc. to DIN 50021SS for extreme conditions
(not required for ordering)
Design series
Code K J Code W 2) A 2)
2)
Voltage 12V = 24V = Connection Connector as per EN 175301-803 2-pin AMP Junior Timer
Code omit T
D3MW_UK.INDD CM_22.01.2008.1
2-55
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Catalogue HY11-3500/UK
Spool 1 2 4 6 11 20 30 8
21 22
Position b P ->A B->T 4 3 4 1 4 2 4 3 4 3 4 3 4 2 P->B A->T 4 3 Position b P->A P->B 5 4 P->A B->T 3 3
P->B 3 6 P->B
P->T 5 P->T 6
A->B 1 5 6 A-> B
A->B 6
D3MW_UK.INDD CM_22.01.2008.1
2-56
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Shift Limits
Catalogue HY11-3500/UK
The diagram below species the shift limits for valves with DC solenoids. Valves with spool position F or M can only be operated up to 70% of the limits. The specications apply to a viscosity 35mm2/s and balanced ow Shift limits, DC voltage
D3MW_UK.INDD CM_22.01.2008.1
2-57
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Dimensions
Catalogue HY11-3500/UK
C, D -style
H, K, M -style
C, D -style
Surface nish BK385 4x M6x40 DIN 912 12.9 13.2 Nm 15% NBR: SK-D3W-30 FPM: SK-D3W-V30
The space necessary to remove the plug per EN 175301-803, design type AF is at least 15 mm. The torque for the screw M3 of the plug has to be 0.5 to 0.6 Nm.
D3MW_UK.INDD CM_22.01.2008.1
2-58
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Characteristics
Catalogue HY11-3500/UK
Pilot Operated Directional Control Valves Series D*1VW (Parker), 4D02V/03/06 (Denison)
The pilot operated directional valves are available with both Parker (series D31DW, D41VW, D81/D91VW and D111VW) and Denison (series 4D02V, 4D03, 4D06) model codes. All valves are pilot operated by an NG6 valve. Pressure and ow of the pilot oil have a signicant inuence on the response time of the spool in the main stage. In order to guarantee a save switching of the spool please choose the appropriate pilot oil supply and drain option. (Spools with a connection P to T need an external pressure supply or an integral check valve. For spools with negative cross-over position the same options are recommended.) The minimum pilot pressure must be ensured for all operating conditions of the directional valve.
2
D31DW
4D02V
D41VW
D81VW
D111VW
D81VW
D3-D11_UK.INDD CM_22.01.2008.1
2-59
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Ordering Code
Catalogue HY11-3500/UK
D
Directional control valve Code 3 4 8 9 11 Code D V Bore 11mm 20mm 26mm 32mm 50mm Style D3 D4, D8/9, D111 Series
1
Pilot NG 06 Style
W
Electrically operated Spool type Spool position
Size NG10 NG16 NG25 NG25 NG32 Code C 2) Standard E 2) 3 position spools all 3 position spools 3 positions. Spring offset in position 0. Operated in position a or b. Spool type 009 2 positions. Spring offset in position 0.
3 position spools Code Spool type a 0 b 001 2) 002 2) 003 3) 004 3) 005 3) 006 3) 007 3) 0091)2) 011 3) 014 3) 015 3) 016 3) 021 3) 022 3) 031 5) 032 5) 054 4) 081 2) 082 2) 2 position spools Code Spool type a b 020 2) 026 3) 030 2)
D3-D11_UK.INDD CM_22.01.2008.1
Operated in position a.
Operated in position b.
F 2)
K 2)
Operated in position b.
Operated in position a.
M 2)
R 3)
2 positions, detent. Operated in position 0 or b. 2 positions, detent. Operated in position 0 or a. No centre in offset position.
S 3)
Code B 2) D 3) H 2)
2 position spools Spool position Spring offset in position b. Operated in position a. Detent, operated in position a or b. No centre or offset position. Spring offset in position a. Operated in position b.
1) 2)
Consider specic spool position. All sizes (D31, D41, D81, D 91, D111) available 3) Only D31, D41, D81, D91 available 4) Only D41, D81, D91, D111 available 5) Only D31, D81, D91 available
2-60
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Ordering Code
Catalogue HY11-3500/UK
W
Pilot oil supply and drain options Seals Solenoid Connector Solenoid voltage options as per EN 175301-803, without plug
(Please order plug separately.
Accessories
Design series
2
Accessories Standard valve w/o accessories Pilot with press. reducing valve Pilot choke, meter-out Stroke adjustment side B Stroke adjustment side A Pilot choke, meter-in Stroke adjustment side A and B
Code 1 2 3 6) 4 7) 5 6
6) 7)
Inlet Internal External Integral check valve Internal External Integral check valve
Code omit 3C 3A 3D 9) 3E 9) 3B 3F
9)
6)
Only D41, D81 available. Not for spools 002, 007, 009, 014, 030, 031, 032, 054 available.
Code N V Code K J U 8) G 8) Y T
8)
Seals NBR FPM Voltage 12V = 24V = 98V = 205V = 110V 50Hz / 120V 60Hz 230V 50Hz / 240V 60Hz
For AC voltage use plug with rectier. Please order rectier plug separately.
Code omit T
Further spool types and solenoid voltages on request. Explosion proof solenoids EEx me ll on request.
D3-D11_UK.INDD CM_22.01.2008.1
2-61
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Ordering Code
Catalogue HY11-3500/UK
Pilot Operated Directional Control Valves Series 4D02V, 4D03, 4D06 (DENISON)
4D
Directional control valve Size
Size NG10 NG16 NG25 Body for 4D02 for 4D03/06 Control 1 solenoid 2 solenoids 2 solenoids and 2 pos. detent pilot valve Code 03 05
Code 03 09
3 position spools Spool position 3 positions. Spring centered to 0. 2 positions. Spring centered to 0. Energized to b. 2 positions. Spring centered to 0. Energized to a. 2 position spools Spool position 2 positions. Spring offset to b. Energized to a. 2 positions. Spring offset to a. Energized to b. 2 positions detent. Operated in a or b. No centre or spring offset position.
06
Code 01
A B
3 position spools Code Spool type a 0 b 01 02 03 07 08 09 10 13 14 46 55 56 2 position spools Code Spool type a b 11 51
a
P
b
T
02
04
D3-D11_UK.INDD CM_22.01.2008.1
2-62
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Ordering Code
Catalogue HY11-3500/UK
Pilot Operated Directional Control Valves Series 4D02V, 4D03, 4D06 (DENISON)
Design series
Seals
Solenoid voltage
Pilot accessories
2
Code 10 * 15 * Pilot accessories 1.0 mm orice (Standard for 4D02V) 1.5 mm orice (Standard for 4D03/06)
Code 1 2 3 4 Code 0 1 2 4 5
Accessories Without Shifting time adjustment (meter-in) Shifting time adjustment (meter-out) Integral check valve in P Shifting time adjustment (meter-in) integral check valve in P Shifting time adjustment (meter-out) integral check valve in P
Solenoid voltage 12V = 24V = 98V = 205 = 110V / 50Hz 120V / 60Hz 230V / 50Hz 240V / 60Hz Code 1 5 Seals NBR FPM
Further spool types, solenoid voltages, position control, hydraulic and mechanical operation on request.
D3-D11_UK.INDD CM_22.01.2008.1
2-63
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Ordering Code
Catalogue HY11-3500/UK
1
Series Pilot NG 06 Style
W
Electrically operated Spool type Spool position
2
Code 3 4 8 9 11 Code D V
Size NG10 NG16 NG25 NG25 NG32 Code C Standard E 3 position spools all 3 position spools 3 positions. Spring offset in position 0. Operated in position a or b. Spool type 009 2 positions. Spring offset in position 0.
3 position spools Code Spool type a 0 b 001 2) 002 5) 003 3) 004 3) 007 5) 0091)4) 011 5) 014 5) 015 3) 2 position spools Code Spool type a b 020 2) 030 5)
Consider specic spool position. 2) All sizes (D31, D41, D81, D91, D111) available 3) Only D31, D41, D81, D91 available 4) Only D41, D81, D91, D111 available 5) Only D41, D81, D91 available
1)
Operated in position b.
Operated in position a.
Code B H
2 position spools Spool position Spring offset in position b. Operated in position a. Spring offset in position a. Operated in position b.
D3-D11_UK.INDD CM_22.01.2008.1
2-64
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Ordering Code
Catalogue HY11-3500/UK
W
Pilot oil supply and drain options Seals Solenoid Connector Solenoid voltage as per options EN 175301-803, without plug
(Please order plug separately.
Accessories
Design series
2
Position control
Code 1 2 3
6)
Inlet Internal External Integral check valve Internal External Integral check valve
Code I3N
Spool position
C I6N 9) I2N I5N 9) I1N I4N 9) C, B, E, F (all spools) C, K, M (spool 9) C, H, K, M (all spools) C, E, F (spool 9)
End position monitored, side A and B Start position monitored, side A and B End position monitored, side B Start position monitored, side B End position monitored, side A Start position monitored, side A
4 7) 5 6 6)
6) 7)
Only D41, D81 available. Not for spools 002, 007, 009, 014, 030 available.
Code N V Code K J U 8) G 8)
8)
The plug M12 x 1 for the position control is included. The monitor switch has to be located on the side to which the spool moves from the spring offset position.
For AC voltage use plug with rectier. Please order rectier plug separately.
Code omit T 9)
9)
For hydraulic presses according to the safety regulations EN 693, solenoid option T (without manual override) and accessories I4N, I5N or I6N (start position monitored) are required.
Attention The adjustment of the position control is factory set and sealed. Replacement and repairs can only be undertaken by the manufacturer.
D3-D11_UK.INDD CM_22.01.2008.1
2-65
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Technical Data
Catalogue HY11-3500/UK
Pilot Operated Directional Control Valves Series D*1VW (Parker), 4D02V/03/06 (Denison)
Directional spool valve Solenoid D31 / (4D02V) NG10 6.0 / 6.6 (7.6 / 8.1) DIN 24340 A10 ISO 4401 NFPA D05 D41 / 4D03 NG16 9.7 / 10.3 DIN 24340 A16 ISO 4401 NFPA D07 D81/91 / 4D06 NG25 17.9 / 18.6 DIN 24340 A25 ISO 4401 NFPA D08 D111 / NG32 67.4 / 68.0 DIN 24340 A32 ISO 4401 NFPA D10
General Design Actuation Series Parker /Denison Size Weight (1/ 2 solenoids) Mounting interface
[kg]
CETOP RP 121-H unrestricted, preferably horizontal [C] -25...+50 (without inductive position control) [C] 0...+50 (with inductive position control)
[bar] Pilot drain internal: P, A B, X: 350; T, Y: 105 (4D02V: P, A, B, X: 315; T, Y: 140) Pilot drain external: P, A B, T, X: 350; Y: 105 (4D02V: P, A, B, T, X: 315; Y:140) Fluid Hydraulic oil in accordance with DIN 51524 / 51525 Fluid temperature [C] -25 ... +70 Viscosity permitted [cSt] / [mm/s] 2.8...400 Viscosity recommended [cSt] / [mm/s] 30...80 Filtration ISO 4406 (1999); 18/16/13 (meet NAS 1638: 7) Flow max. [l/min] 150 / (170) 300 700 2000 Leakage at 350 bar (per ow path) [ml/min] up to 100* / (72...422*) up to 200* up to 800* up to 5000* *depending on spool Opening pressure integral check valve Minimum pilot supply pressure Static / Dynamic Step response at 95% DC solenoids Pilot pressure [bar] [bar] n.a. 5 / (7) see p/Q diagram see p/Q diagram 5 n.a.
AC solenoids
Pilot pressure
[ms] Energized / De-energized 50 bar 60 / 40 (50/60) 100 bar 55 / 40 (50/60) 250 bar 55 / 40 (50/50) 350 bar 55 / 40 (50/50) 50 bar 40 / 30 (30/50) 100 bar 35 / 30 (30/50) 250 bar 35 / 30 (30/50) 35 / 30 (30/50) 350 bar
95 / 65 75 / 65 60 / 65 60 / 65 75 / 55 65 / 55 40 / 55 40 / 55
150 / 170 110 / 170 90 / 170 85 / 170 130 / 155 90 / 155 70 / 155 65 / 155
470 / 390 320 / 390 210 / 390 200 / 390 450 / 375 300 / 375 190 / 375 180 / 375
Electrical characteristics Duty ratio Protection class Supply voltage / ripple Tolerance supply voltage Current consumption hold Current consumption in rush Power consumption hold Power consumption in rush Solenoid connection Wiring min. Wiring length max.
100% ED; CAUTION: coil temperature up to 150 C possible IP 65 in accordance with EN 60529 (plugged and mounted) Code K J U G Y T [V] 12 V = 24 V = 98 V = 205 V = 110V at 50Hz/ 230V at 50Hz/ 120V at 60Hz 240V at 60Hz [%] 10 10 10 10 5 5 [A] 2.5 1.25 0.31 0.15 0.58 / 0.49 0.31 / 0.26 [A] 2.5 1.25 0.31 0.15 2.1 / 2.0 1.05 / 1.0 [W] 30 30 30 30 64 / 59 VA 68 / 62 VA [W] 30 30 30 30 231 / 240 VA 231 / 240 VA Connector as per EN 175301-803, solenoid identication as per ISO 9461. [mm] 3 x 1.5 recommended [m] 50 recommended
With electrical connections the protective conductor (PE W) must be connected according to the relevant regulations.
D3-D11_UK.INDD CM_22.01.2008.1
2-66
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Position Control
Catalogue HY11-3500/UK
Pilot Operated Directional Control Valves Series D*1VW (Parker), 4D02V/03/06 (Denison)
1
3
+Vs 0V
ASEW001D10
0V
Denitions Start position monitored: The valve is de-energized. The inductive switch gives a signal at the moment (below 15% spool stroke) when the spool leaves the spring offset position.
End position monitored: The inductive switch gives a signal before the end position is reached. (above 85% spool stroke).
D3-D11_UK.INDD CM_22.01.2008.1
2-67
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Catalogue HY11-3500/UK
Pilot Operated Directional Control Valves Series D*1VW (Parker), 4D02V/03/06 (Denison)
for each spool type, operating position and ow direction is given in the table below.
Spool Code 001 002 003 004 005 006 007 009 011 014 015 016 020 021 022 026 030 054
P-A D3 D4 3 1 3 1 3 1 3 1 3 2 3 1 4 1 3 2 3 1 3 1 4 1 4 2 3 3 4 2 3 8 3 3 3 2 2
P-B D3 D4 3 1 3 2 4 2 3 1 4 2 3 2 3 1 3 9 3 1 4 1 3 2 3 2 4 5 3 8 4 2 3 5 1 3 3
B-T D3 D4 1 5 1 6 1 6 1 5 1 5 1 6 1 5 1 10 1 5 1 5 1 6 1 5 1 5 1 3 1 7 7
4D02V
Spool Code 01 02 03 07 08 09 10 11 13 14 46 51 55 56 P-A 3 3 3 4 2 2 2 5 2 4 8 6 4 P-B 3 3 3 6 3 2 3 3 4 3 9 4 7 Curve number P-T A-T 7 4 2 2 6 4 4 1 4 2 1 2 7 3 8 9 B-T 3 4 5 10 4 4 4 5 4 4 9 6
D3-D11_UK.INDD CM_22.01.2008.1
2-68
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Catalogue HY11-3500/UK
Pilot Operated Directional Control Valves Series D*1VW (Parker), 4D02V/03/06 (Denison)
Integral check valve in the P port Mounting an integral check valve in the P port is necessary to build up pilot pressure for valves with P to T connection and internal pilot oil supply. The pressure Flow curve 4D02V
difference at the integral check valve (see performance curves) is to be added to all ow curves of the P-port of the main valve. Directional valves with an integral check valve are available for the series 4D02V, D41/4D03 and D81/4D06.
D3-D11_UK.INDD CM_22.01.2008.1
2-69
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Catalogue HY11-3500/UK
Pilot Operated Directional Control Valves Series D*1VW (Parker), 4D02V/03/06 (Denison)
2
Series 4D02V
PV TV 3 1 T
open,
closed
B
0 b
Pilot oil Inlet Outlet internal external external external internal internal
2 Y (drawn offset)
M6 DIN906
external internal
Series D41VW
Series D81/91VW
Series D111VW
2-70
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Dimensions
D31DW
Catalogue HY11-3500/UK
Pilot Operated Directional Control Valves Series D*1VW (Parker), 4D02V/03/06 (Denison)
175
11
1cm
mc1
83
01M
30
12
70 72
93
33.5
6.8 87.5
110
Surface nish BK385 4x M6x40 DIN 912 12.9 13.2 Nm 15% NBR: SK-D31DW-N-91 FPM: SK-D31DW-V-91
4D02V
Surface nish BK385 4x M6x40 DIN 912 12.9 13.2 Nm NBR: SK-4D02V-B1 FPM: SK-4D02V-B5
The space necessary to remove the plug per EN 175301-803, design type AF is at least 15 mm. The torque for the screw M3 of the plug has to be 0.5 to 0.6 Nm.
D3-D11_UK.INDD CM_22.01.2008.1
2-71
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
195
M10
Dimensions
D41VW/4D03
Catalogue HY11-3500/UK
Pilot Operated Directional Control Valves Series D*1VW (Parker), 4D02V/03/06 (Denison)
2
136 220
Stroke adjustment
Monitor switch
1cm
01M
mc1
M10
11
92
94
101
63
11
165
275
Surface nish BK320 4x M10x60 2x M6x55 DIN 912 12.9 63 Nm 15% 13.2 Nm 15% NBR: SK-D41DW-N-91 FPM: SK-D41DW-V-91
D81VW/4D06, D91VW
223
Stroke adjustment
Monitor switch
57
12
116
118
117
76
13.5
230
340
Surface nish BK360 6x M12x75 DIN 912 12.9 108 Nm 15% NBR: SK-D81VW-N-91 / SK-D91VW-N-91 FPM: SK-D81VW-V-91 / SK-D91VW-V-91
The space necessary to remove the plug per EN 175301-803, design type AF is at least 15 mm. The torque for the screw M3 of the plug has to be 0.5 to 0.6 Nm.
D3-D11_UK.INDD CM_22.01.2008.1
2-72
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Dimensions
D111VW
Catalogue HY11-3500/UK
Pilot Operated Directional Control Valves Series D*1VW (Parker), 4D02V/03/06 (Denison)
Monitor switch
347
59
20
198
200
90
22
319
429
Surface nish BK386 6x M20x90 DIN 912 12.9 517 Nm 15% NBR: SK-D111VW-N-91 FPM: SK-D111VW-V-91
The space necessary to remove the plug as per EN 175301-803, design type AF is at least 15 mm. The torque for the screw M3 of the plug has to be 0.5 to 0.6 Nm.
D3-D11_UK.INDD CM_22.01.2008.1
2-73
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Catalogue HY11-3500/UK
Notes
D3-D11_UK.INDD CM_22.01.2008.1
2-74
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Characteristics
Catalogue HY11-3500/UK
Pilot Operated Directional Control Valves Series D1VP, D3DP, D4P, D9P, D11P
The D1VP is a hydraulically controlled 4/3 or 4/2 way directional control valve. The valve can be operated either by the pilot ports X and Y via the subplate or by the connection of an external pilot pipe directly on the valve body. The D3DP, D4P, D9P and D11P are hydraulically controlled 4/3 or 4/2 way directional control valves. The valves are operated by the pilot ports X and Y via the subplate. Pressure and ow of the pilot oil have a signicant inuence on the response time of the spool. The minimum pilot pressure must be ensured for all operating conditions of the directional valve.
Technical data
General Design Actuation Series Size Weight Mounting interface Directional spool valve Hydraulic D1VP D3DP NG06 NG10 [kg] 1.3 3.7 DIN 24340 A06 DIN 24340 A10 ISO 4401 ISO 4401 NFPA D03 NFPA D05 unrestricted, preferably horizontal [C] -25...+50 [bar] P, A B, T: 350; P, A B, T: 350; P, A B, T: 350; X, Y: 210 X, Y: 210 X, Y: 350 1) Hydraulic oil in accordance with DIN 51524 / 51525 -25 ... +70 2.8...400 30...80 ISO 4406 (1999); 18/16/13 (meet NAS 1638: 7) 80 130 300 up to 60* up to 100* up to 200* P, A B, T: 350; X, Y: 350 1) P, A B, T: 350; X, Y: 350 1)
D4P D9P NG16 NG25 9.0 17.0 DIN 24340 A16 DIN 24340 A25 ISO 4401 ISO 4401 NFPA D07 NFPA D08 CETOP RP 121-H
D11P NG32 66.0 DIN 24340 A32 ISO 4401 NFPA D10
Fluid Fluid temperature [C] Viscosity permitted [cSt] / [mm/s] Viscosity recommended [cSt] / [mm/s] Filtration Flow max. [l/min] 700 2000 Leakage at 350 bar (per ow path) [ml/min] up to 800* up to 5000* * depending on spool 5 / 350 1) 5 / 350 1) Pilot supply pressure (min/max) [bar] 15 /210 15 /210 5 / 350 1) Static / Dynamic Step response The response times depend on the pilot oil pressure and on the speed of the increase / decrease of the pilot pressure. Recommended values are (act./deact.) [ms] 13 / 28 20 / 30 50 / 60 100 / 150 300 / 370
1)
DVP_UK.INDD CM_22.01.2008.1
2-75
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Ordering Code
Catalogue HY11-3500/UK
P
Hydraulically operated Spool type Spool position Seals
90
Pilot port with G1/8 pipe thread
(not required for ordering)
2
1 2 3 4 5 6 7 8* 9* 10 11 14 15 16 21 22 31 32 76 78 81 82 102
Directional Size control DIN NG 06 valve CETOP 03 NFPA D03 3 position spools Code Spool type a 0 b
Design series
Code N V
Code C Standard E
3 position spools all 3 position spools 3 positions. Spring offset in position 0. Operated in position a or b. Spool type 8 and 9 2 positions. Spring offset in position 0.
Operated in position a.
Operated in position b.
Operated in position b.
Operated in position a.
Code B D H
2 position spools Spool position Spring offset in position b. Operated in position a. Detent, operated in position a or b. No centre or offset position. Spring offset in position a. Operated in position b.
2-76
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Ordering Code
Catalogue HY11-3500/UK
P
Hydraulically operated Spool type Spool position
2
Pilot oil supply and drain external/ external Seals
(not required for ordering)
Directional Size control DIN NG 10 valve CETOP 05 NFPA D05 3 position spools Code Spool type a 0 b 1 2 3 4 5 6 7 8* 9* 10 11 14 15 16 21 22 31 32 76 78 81 82 102 2 position spools Code Spool type a b 20 26 30 101
* Consider specic spool position.
Design series
2
Seals NBR FPM
Code N V
Code C Standard E
3 position spools all 3 position spools 3 positions. Spring offset in position 0. Operated in position a or b. Spool type 8 and 9 2 positions. Spring offset in position 0.
Operated in position a.
Operated in position b.
Operated in position b.
Operated in position a.
Code B D H
2 position spools Spool position Spring offset in position b. Operated in position a. Detent, operated in position a or b. No centre or offset position. Spring offset in position a. Operated in position b.
2-77
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Ordering Code
Catalogue HY11-3500/UK
D
Directional control valve Size
P
Hydraulically operated Spool type Spool position
2
Code 4 9 11
Size NG16 NG25 NG32 Code C 2) Standard E 2) 3 position spools all 3 position spools 3 positions. Spring offset in position 0. Operated in position a or b. Spool type 9 2 positions. Spring offset in position 0.
Operated in position a.
Operated in position b.
6 3) 7 3) 9 1) 2) 11 3) 14 3) 15 3) 16 3) 21
3)
F 2)
K 2)
Operated in position b.
Operated in position a.
M 2)
R 3)
S 3)
Code B D 3) H
2 position spools Spool position Spring offset in position b. Operated in position a. Detent, operated in position a or b. No centre or offset position. Spring offset in position a. Operated in position b.
DVP_UK.INDD CM_22.01.2008.1
Start
Ordering Code
Index
Ordering Code
Catalogue HY11-3500/UK
2
Pilot oil supply and drain external/ external Seals Accessories Design series
Seals NBR FPM Accessories Standard valve w/o accessories Pilot choke, meter-out Stroke adjustment side B Stroke adjustment side A Pilot choke, meter-in Stroke adjustment side A and B
DVP_UK.INDD CM_22.01.2008.1
2-79
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Catalogue HY11-3500/UK
21 22
A->B 3
Flow curve
DVP_UK.INDD CM_22.01.2008.1
2-80
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Catalogue HY11-3500/UK
21 22
A->B 6
Flow curve
DVP_UK.INDD CM_22.01.2008.1
2-81
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Catalogue HY11-3500/UK
Spool Code 1 2 3 4 5 6 7 9 11 14 15 16 20 21 22 26 30 54
P-A 1 1 1 1 2 1 1 2 1 1 1 2 3 2 8 3 2 2
P-B 1 2 2 1 2 2 1 9 1 1 2 2 5 8 2 5 3 3
A-T 4 4 5 5 3 3 4 7 4 4 4 3 3 2 6 6
B-T 5 6 6 5 5 6 5 10 5 5 6 5 5 3 7 7
DVP_UK.INDD CM_22.01.2008.1
2-82
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Dimensions
D1VP
Catalogue HY11-3500/UK
Surface nish BK375 4x M5x30 DIN 912 12.9 7.6 Nm 15% NBR: SK-D1VP-70 FPM: SK-D1VP-V70
D3DP
Surface nish BK385 4x M6x40 DIN 912 12.9 13.2 Nm 15% NBR: SK-D3DP-35 FPM: SK-D3DP-V35
DVP_UK.INDD CM_22.01.2008.1
2-83
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Dimensions
D4P
Catalogue HY11-3500/UK
Surface nish BK320 4x M10x60 2 x M6x55 DIN 912 12.9 63 Nm 15% 13.2 Nm 15% NBR: SK-D41VW-70 FPM: SK-D41VW-V70
D9P
Surface nish BK360 6x M12x75 DIN 912 12.9 108 Nm 15% NBR: SK-D91VW-70 FPM: SK-D91VW-V70
DVP_UK.INDD CM_22.01.2008.1
2-84
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Dimensions
D11P
Catalogue HY11-3500/UK
Surface nish BK386 6x M20x90 DIN 912 12.9 517 Nm 15% NBR: SK-D111VW-70 FPM: SK-D111VW-V70
DVP_UK.INDD CM_22.01.2008.1
2-85
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Notes
Catalogue HY11-3500/UK
DVP_UK.INDD CM_22.01.2008.1
2-86
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Characteristics
Catalogue HY11-3500/UK
The D1DL, D3DL, D4L and D9L are 5 chamber 4/3 or 4/2 way directional control valves. They are operated by a hand lever which is directly connected to the spool. The hand lever can be located either on the A or B side. Spring offset and detent designs are available.
Technical data
General Design Actuation Series Size Weight Mounting interface Directional spool valve Lever D1DL NG06 [kg] 1.4 DIN 24340 A06 ISO 4401 NFPA D03
D3DL D4L NG10 NG16 3.7 9.0 DIN 24340 A10 DIN 24340 A16 ISO 4401 ISO 4401 NFPA D05 NFPA D07 CETOP RP 121-H unrestricted, preferably horizontal [C] -25...+50 [bar] external drain P, A B, T: 350; X, Y: 10 internal drain P, A B: 350; T, X, Y: 10 Hydraulic oil in accordance with DIN 51524 / 51525 -25 ... +70 2.8...400 30...80 ISO 4406 (1999); 18/16/13 (meet NAS 1638: 7) 80 130 300 up to 60* up to 100* up to 200* P, A B: 350; T: 10 P, A B: 350; T: 10
D9L NG25 17.0 DIN 24340 A25 ISO 4401 NFPA D08
Fluid Fluid temperature [C] Viscosity permitted [cSt] / [mm/s] Viscosity recommended [cSt] / [mm/s] Filtration Flow max. [l/min] Leakage at 350 bar (per ow path) [ml/min] * depending on spool
700 up to 800*
DL_UK.INDD CM_22.01.2008.1
2-87
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Ordering Code
Catalogue HY11-3500/UK
D
Directional control valve Size
D
5-chamber valve Actuation Spool type Spool position Seals
(not required for ordering)
Design series
2
Code 1 3
Size DIN NG06, CETOP03 NFPA D03 DIN NG10, CETOP05 NFPA D05 Actuation Hand lever side B Hand lever side A Code C Standard
Code N V
Code L LB
3 position spools all 3 position spools 3 positions. Spring offset in position 0. Operated in position a or b. Spool type 9 2 positions. Spring offset in position 0.
Operated in position a.
Operated in position b.
Operated in position b.
Operated in position a.
3 positions, detent. No centre in offset Operated in position a, 0or b. position. 2 positions, detent. Operated in position 0 or b. 2 positions, detent. Operated in position 0 or a. No centre in offset position.
Code B 4) D H 5)
2 position spools Spool position Spring offset in position b. Operated in position a. Detent, operated in position a or b. No centre or offset position. Spring offset in position a. Operated in position b.
For D1D only operation LB available For D3D operation L and LB available 5) For D1D only operation L available For D3D operation L and LB available
4)
2-88
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Ordering Code
Catalogue HY11-3500/UK
D
Directional control valve Size Actuation Spool type Spool position Pilot oil drain Seals
(not required for ordering)
Design series
Code Code 4 9 Code L LB Bore 20mm 32mm Size NG16 NG25 Code 2 3) Actuation Lever side B Lever side A Code 3 position spools Code Spool type a 0 b 1 2 3 4 6 1) 7 9 2) 11 14 15 2 position spools Code Spool type a b 20 30
1) 2) 3)
5 4)
C Standard E
3 position spools all 3 position spools 3 positions. Spring offset in position 0. Operated in position a or b. Spool type 9 2 positions. Spring offset in position 0.
Operated in position a.
Operated in position b.
Operated in position 0.
Operated in position 0.
Operated in position b.
Operated in position a.
Operated in position 0.
3 positions, detent. No centre in offset Operated in position a, 0or b. position. No centre in offset position. 2 positions, detent. Operated in position 0 or b. 2 positions, detent. Operated in position 0 or a. No centre in offset position.
Code B
2 position spools Spool position Spring offset in position b. Operated in position a. Detent, operated in position a or b. No centre or offset position. Spring offset in position a. Operated in position b.
D H
2-89
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Catalogue HY11-3500/UK
Spool 1 2 4 20 9
P->A 4 P->A
P->B 4 P->B
P->T 6 P->T 9
A->B 1 9 A-> B
D3DL
Spool 1 2 4 6 10 20 9 Position b P->A B->T 4 3 4 1 4 2 4 3 4 4 3 P->B A->T 4 4 Position a P->B A->T 4 3 4 1 4 2 4 3 4 4 3 P->A B->T 4 4 P->A 3 6 P->A P->B 3 6 P->B Position 0 A->T B->T 1 1 3 3 A->T B->T P->T 5 P->T 6 A->B 1 5 6 A-> B
DL_UK.INDD CM_22.01.2008.1
2-90
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Catalogue HY11-3500/UK
D9L
Spool Code 1 2 3 4 7 9 14 15 20 30 P-A 3 2 4 4 3 4 1 2 6 3 P-B 2 1 2 3 1 8 3 4 5 2 Curve number P-T 1 7 9 7 A-T 3 3 3 3 3 4 5 5 6 3 B-T 5 5 6 5 5 10 3 3 8 5
DL_UK.INDD CM_22.01.2008.1
2-91
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Dimensions
D1DL
Catalogue HY11-3500/UK
D1DLB
7.6 Nm 15%
2-92
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Dimensions
D3DL
Catalogue HY11-3500/UK
D3DLB
13.2 Nm 15%
2-93
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Dimensions
D4L
Catalogue HY11-3500/UK
D4LB
136
240
1cm
11 92 94 63
44.5
M10
11 298
165
Surface nish BK320 4x M10x60 2x M6x55 DIN 912 12.9 63 Nm 13.2 Nm 15% NBR: SK-D4L-60 FPM: SK-D4L-V60
DL_UK.INDD CM_22.01.2008.1
2-94
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Dimensions
D9L
Catalogue HY11-3500/UK
D9LB
Surface nish BK360 6x M12x75 DIN 912 12.9 108 Nm 15% NBR: SK-D9L-70 FPM: SK-D9L-V70
DL_UK.INDD CM_22.01.2008.1
2-95
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Notes
Catalogue HY11-3500/UK
DL_UK.INDD CM_22.01.2008.1
2-96
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Plugs
Catalogue HY11-3500/UK
Plug EN 175301-803 *, style AF Protection class IP 65 for voltages up to 250V Plug with LED 24V DC Plug with lamp insert 120V AC Plug with lamp insert 230V AC Plug with LED 24 V DC and suppressing circuit Plug with rectier: Bridge-type rectier with silicon diodes. Varistors are used to protect the diodes against power surges from the power supply up to 250V AC. Plug with cable strain relief and transparent cover Inserts for plug 5001723 and 5001724 Bridge-type rectier up to 250V AC 7 Bridge-type rectier with lamp 250V AC
Fig. 5
Fig. 6
Fig. 7
Fig. 8
The angled plug for M12x1 is a 5-pin design. The connections in the plug can be screwed in. The plug can be turned 4 x 90.
access02_UK.INDD CM_22.01.2008.1
2-97
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Actuator Kits
Catalogue HY11-3500/UK
Solenoid kit (displayed: EN plug) A solenoid kit contains tube, coil, retainer and seals for the solenoid.
2
For D1VW standard
Solenoid kits: AK-D1VW-S-... Voltage Volt/Hertz 12V= 24V= 98V= 205V= 110V/50Hz / 120V/60Hz 230V/50Hz / 240V/60Hz (Soft shift on request) Voltage Code K J U G Y T EN plug D1VW KW-91 JW-91 UW-91 GW-91 YW-91 TW-91 (Example: AK-D1VW-S-JW-91) EN plug without manual override (Code T) D1VW KWT-91 JWT-91 UWT-91 GWT-91
Coil kits: AK-D1VW-C-... Voltage Volt/Hertz 12V= 24V= 98V= 205V= 110V/50Hz / 120V/60Hz 230V/50Hz / 240V/60Hz
(Example: AK-D1VW-C-JW-91) Voltage EN plug Code D1VW KW-91 K JW-91 J U UW-91 G GW-91 YW-91 Y TW-91 T
D1VW 8 Watt
Solenoid kits: AK-D1VW-S-... Voltage Volt/Hertz 24V= Voltage Code J EN plug D1VW JWL-91 M12x1 DESINA (Code DLJ5) D1VW JDLJ5-91 Coil kits: AK-D1VW-C-... M12x1 DESINA EN plug (Code DLJ5) D1VW D1VW JWL-91 JDLJ5-91
D3W
Solenoid kits: AK-D3W-S-... (Soft shift on request) (Example: AK-D3W-S-JW-30) EN plug without manual EN plug with 210bar tank Voltage Voltage EN plug override (Code T) pressure (Code H) Volt/Hertz Code D3W D3W D3W 12V= K KW-30 KWT-30 KW-30 24V= J JW-30 JWT-30 JW-30 98V= U UW-30 UWT-30 UW-30 205V= G GW-30 GWT-30 GW-30 110V/50Hz YW-30 Y YWH-30 120V/60Hz 230V/50Hz TW-30 T TWH-30 240V/60Hz Other solenoids, coil kits and tube kits on request.
access02_UK.INDD CM_22.01.2008.1
Coil kits: AK-D3W-C-... EN plug without manual EN plug override (Code T) D3W D3W KW-30 KWT-30 JW-30 JWT-30 UW-30 UWT-30 GW-30 GWT-30 YW-30 TW-30
2-98
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Catalogue HY11-3500/UK
Ports P, A, B, T X, Y P, A, B, T X, Y P, A, B, T X, Y P, A, B, T X, Y P, A, B, T X, Y P, A, B, T X, Y
Dimensions inner x section 9.25 x 1.78 4.47 x 1.78 12.42 x 1.78 10.82 x 1.78 21.89 x 2.62 10.82 x 1.78 29.82 x 2.62 20.29 x 2.62 34.59 x 2.62 20.29 x 2.62 53.57 x 3.53 14.00 x 1.78
Quantity 1) 4 2 5 2 4 2 4 2 4 2 4 2
D**P Hydr.
Seated valve
Valve series D1SE Solenoid Material NBR FPM D1SE SK-D1SE-70 SK-D1SE-V70
access02_UK.INDD CM_22.01.2008.1
2-99
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Slip-In Orices
Catalogue HY11-3500/UK
Slip-in orice for P, A, B port of directional control valves NG6 and NG10
DK
2
Code D1VW91 D3W30 Size NG6 NG10
Orice kit
Size
Orice size Code 00 06 08 09 10 11 12 14 15 17 18 20 25 30 45 Orice without orice 0.6 mm 0.8 mm 0.9 mm 1.0 mm 1.1 mm 1.2 mm 1.4 mm 1.5 mm 1.7 mm 1.8 mm 2.0 mm 2.5 mm 3.0 mm 4.5 mm x x x x x x x NG6 x x x x x x x x x x x x x x x NG10 x
Dimensions NG6
NG10
7.9 d
8.2 8.8
access02_UK.INDD CM_22.01.2008.1
1.2
3.9
2-100
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Mounting Patterns
Size 6, mounting pattern to DIN 24340-A6
Catalogue HY11-3500/UK
34.9 15.9
14.3 1.6*
P X
90
20 8
71.5*
69.8*
57.2
55.6
L A
M6x12 deep
M10x20 deep
With * marked dimensions 0.1mm. All other dimensions 0.2mm. Subplates and manifolds see chapter 12.
access02_UK.INDD CM_22.01.2008.1
2-101
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index
Mounting Patterns
Catalogue HY11-3500/UK
With * marked dimensions 0.1mm. All other dimensions 0.2mm. Subplates and manifolds see chapter 12.
access02_UK.INDD CM_22.01.2008.1
2-102
Parker Hannin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Start
Ordering Code
Index