Other Prepking products A) Offline Testing engine Use the offline Testing engine product to practice the questions in an exam environment. B) Study Guide (not available for all exams) Build a foundation of knowledge which will be useful also after passing the exam. Latest Version We are constantly reviewing our products. New material is added and old material is updated. Free updates are available for 90 days after the purchase. You should check your member zone at Prepking and update 3-4 days before the scheduled exam date. Here is the procedure to get the latest version: 1.Go towww.Prepking.com 2.Click on Member zone/Log in (right side) 3. Then click My Account 4.The latest versions of all purchased products are downloadable from here. Just click the links. For most updates,it is enough just to print the new questions at the end of the new version, not the whole document. Feedback If you spot a possible improvement then please let us know. We always interested in improving product quality. Feedback should be send to feedback@Prepking.com. You should include the following: Exam number, version, page number, question number, and your login ID. Our experts will answer your mail promptly. Copyright Each PDF file contains a unique serial number associated with your particular name and contact information for security purposes. So if we find out that a particular PDF file is being distributed by you, Prepking reserves the right to take legal action against you according to the International Copyright Laws. Explanations This product does not include explanations at the moment. If you are interested in providing explanations for this exam, please contact feedback@Prepking.com.

www.Prepking.com

1. Which statements are true about the HP StorageWorks Command View XP Advanced Edition CLI? (Select two.) A. CLI cannot be used for license management. B. Input can be single line entries or scripted batch files. C. CLI is a separately licensed product with the XP24000. D. When installed, the CLI is executed from the SVP in the array. E. CLI is used if a text-based interface is preferred over the GUI or when it is more efficient to run scripts or batch files to manage XP disk arrays. Answer: BE 2. Where does the HP StorageWorks Command View XP Advanced Edition management server store configuration and statistics information? A. out on the individual host agents B. in shared memory of the XP array C. on the SVPs of each array subsystem D. in a local database on the management server Answer: D 3. When must a customer use HP StorageWorks Command View XP Advanced Edition over Remote Web Console XP? A. simple LUN management B. CLI based array management C. Business Copy XP management D. centralized management of multiple XP arrays Answer: D 4. A customer wants to manage their storage environment using HP Storage Essentials. Which XP device software tool is required to allow HP Storage Essentials to manage an XP24000 array? A. External Storage XP B. Remote Web Console XP C. LUN Configuration and Security Manager XP D. A separate software license is not required, as the capability is included in HP Storage Essentials Answer: D 5. Which additional features are added by HP StorageWorks Command View XP Advanced Edition over Remote Web Console XP? (Select three.) A. array administration B. SNMP trap forwarding C. single sign-on user authentication

www.Prepking.com

D. logical grouping of storage capacity E. assignment of cache LUNs to hosts F. displaying host specific device information Answer: CDF 6. Which features offered through HP StorageWorks Command View XP Advanced Edition are not available with Remote Web Console XP? (Select two.) A. reporting B. cache partitioning C. SNMP trap forwarding D. TSM and Replication Monitor E. automation of BC/CA HORCM file creation Answer: AE 7. A customer wants to use the copy pair operations feature of HP StorageWorks Command View XP Advanced Edition. What is required? (Select two.) A. a host agent B. RAID Manager XP C. an external database D. at least 32GB of cache Answer: AB 8. Which XP array component transfers data between disk drives and cache memory? A. Disk Adapter (DKA) B. Shared Memory PCB C. Channel Adapter (CHA) D. Service Processor (SVP) Answer: A 9. A customer has a heterogeneous environment consisting of AIX and Solaris servers. Which software products can be used to implement an extended application failover solution? (Select two.) A. Metro Cluster B. ServiceGuard C. Cluster Extension XP D. Continuous Access XP E. LUN Security XP Extension Answer: CD 10. What is the back-end architecture of the XP24000? A. Ultra SCSI

www.Prepking.com

B. Serial ATA C. FC-AL 4Gb D. FC-SW 2Gb Answer: C 11. Which statement is correct about Performance Advisor XP? A. It automatically tunes performance over a 24 hour period of time. B. It has the ability to set and relax host priorities by performance policies. C. It collects data on a real-time basis and displays current performance patterns. D. It allows for intelligent allocations of array resources for service-level oriented deployment. Answer: C 12. Which software allows XP disk array resources to be allocated to hosts by setting performance limits? A. AutoLUN XP B. Command View XP C. Resource Manager XP D. Performance Control XP E. Performance Advisor XP Answer: D 13. Which statements are true when using the 16-port CHA pair, rather than the 8-port CHA pair? (Select two.) A. There is improved high availability functionality. B. There is improved front-end array performance. C. A maximum of two are supported per XP24000. D. Fibre Channel connectivity (port count) increases. E. The number of heterogeneous host types increases. F. Front-end array performance is typically not increased. Answer: DF 14. Which statements are true about AutoLun XP? (Select two.) A. It provides on-line LUN expansion. B. It provides automatic or manual backend load leveling. C. It provides seamless failover in the event of cluster failures. D. It provides automatic path failover in the event of an HBA or CHA port failure. E. It provides for migration of data from RAID5 to RAID1 without host interruption. Answer: BE 15. Which statements are true about the XP24000 cache? (Select three.) A. It supports duplexed reads.

www.Prepking.com

B. It supports duplexed writes. C. It is divided across two power domains. D. It is used for DKA control and command. E. It is a temporary storage area for data from the host prior to being written to disk. Answer: BCE 16. Which statements describe the advantages of Continuous Access XP Journal? (Select two.) A. It minimizes the use of cache. B. It provides synchronous replication. C. It is a multi-site disaster tolerance solution with replication over FICON. D. It is a one-to-one disaster tolerance solution for customers with high bandwidth between sites. E. It is a multi-site disaster tolerance solution for customers with limited bandwidth between sites. Answer: AE 17. Which statements about OPEN-V volumes are correct? (Select three.) A. OPEN-V volumes are fixed size. B. OPEN-V volumes cannot be used in external storage. C. OPEN-V volumes with different sizes can be created in the same parity group. D. Space freed by deleting OPEN-V volumes can be re-used to create new OPEN-V volumes. E. Single OPEN-V volumes can be deleted from a parity group without affecting other OPEN-V volumes in the same parity group. F. The Make Volume function is used to create additional OPEN-V volumes without affecting other OPEN-V volumes in the same parity group. Answer: CDE 18. What is the purpose of the Make Volume function in Remote Web Console? A. create LUSE volumes B. create Open-3 volumes C. create Open-V volumes D. assign Open-V volumes to host ports Answer: C 19. Which statement is true about LUSE? A. A LUSE volume cannot be extended online. B. Existing LUSE volume cannot be expanded. C. A path defined LDEV cannot be added to the LUSE. D. A LUSE volume can be decreased in size without losing data. Answer: C 20. Which statements are correct about LUSE volumes on the XP24000? (Select two.)

www.Prepking.com

A. A LUSE volume can be created from different CUs. B. A LUSE volume can be created with different emulation types. C. A LUSE volume can be created with LDEVs of different parity groups. D. A LUSE volume can be increased in size only if it has no paths defined. E. A LUSE volume can only be created with LDEVs with contiguous LDEV numbers. Answer: AC 21. A customer identified a need for disk-based backups and online archival storage, but has serious budget constraints. Which option provides cost-effective storage for this opportunity in an XP environment? A. LUSE volumes using large RAID 5 parity groups B. FlexCopy XP using volumes from external storage arrays C. External Storage XP using volumes from external storage arrays D. OPEN-V Volumes created from unused disk space left over from OPEN-3 and OPEN-9 Volumes Answer: C 22. A customer wants to buy an XP24000 with 10TB of usable storage, RAID1, an internal disk for the XP array, and use an additional 5TB, RAID1 in external MSA1500 storage. How many TB of Array Manager XP must be licensed? A. 10TB B. 15TB C. 20TB D. 25TB Answer: C 23. A customer connected an MSA1000 to an XP24000 using External Storage XP. Which XP disk array software tools can be used with the external disk array? (Select three.) A. Auto LUN XP B. Business Copy XP C. Data Exchange XP D. Continuous Access XP E. LUN Security XP Extension F. LUN Configuration and Security Manager XP Answer: ABF 24. An EMC DMX is connected to an XP24000 as external storage. A host is connected to a pair of Fibre Channel ports on the XP24000. Which statement is true? A. The operating system of the host does not need to be supported by DMX. B. The host can only access internal XP LUNs or external storage LUNs, but not both. C. EMCs PowerPath failover software is required on the host to access the external storage.

www.Prepking.com

D. Separate HBAs are required in the host to access both internal XP LUNs and external storage LUNs. Answer: A 25. A customer has a leased EMC Symmetrix array and the lease is about to expire. The customer wants to migrate the data from the EMC array onto an XP24000. Which XP disk array software tool can be used in this solution? A. FlexCopy XP B. Business Copy XP C. External Storage XP D. Continuous Access XP Answer: C 26. How are external storage LUs distinguished from internal storage LUs when using External Storage XP? A. External storage is not viewable when using XP specific tools. B. Internal storage LUs and external storage LUs are displayed the same within XP Disk Array tools. C. Internal storage LUs are considered LDEVs, whereas external storage LUs are considered VDEVs. D. Internal storage LUs can use OPEN-L emulation, whereas external storage LUs use OPEN-E emulation. Answer: C 27. Which business benefits does HP StorageWorks External Storage XP provide? (Select two.) A. reduced number of CHA pairs B. simplified management for all storage arrays C. increased availability to external storage arrays D. investment protection for external storage arrays E. improved performance on external storage arrays Answer: BD 28. Which statement is true about External Storage XP? A. CHA ports used to connect to external storage cannot be configured as host ports. B. Difference Bitmaps for Business Copy volumes on external storage reside on the external storage. C. For an MSA1000 used with External Storage XP, external LUs on an MSA1000 not involved in external storage may be accessed directly. D. For an XP array used with External Storage XP, external LUs on an XP array not involved in external storage may not be accessed directly. Answer: A 29. Which Business Copy state allows an S-VOL to be read and write accessible? A. PAIR B. PSUS

www.Prepking.com

C. COPY (PD) D. COPY (RS) Answer: B 30. Click the Exhibit button. With Swap and Freeze enabled on Business Copy XP, what represents the state of the data after the quick restore operation?

A. P-VOL=12345; S-VOL=12345 B. P-VOL=12345; S-VOL=abcde C. P-VOL=abcde; S-VOL=12345 D. P-VOL=abcde; S-VOL=abcde Answer: B 31. With Business Copy XP, how many full (no snapshots) secondary volumes can be created in the first tier, and how many copies can be created for a single secondary volume? A. 2; 2 B. 2; 8 C. 3; 2 D. 3; 9 Answer: C 32. Which factors affect Business Copy operation times for initial copy to complete? (Select three.) A. shared memory B. number of CHA pairs C. workload on XP array D. Business Copy Journal Index E. HDD Performance (Spindle Speed) F. P-VOL and S-VOL locations (such as different RAID groups, DKA sets) Answer: CEF 33. Which statements are correct about Business Copy S-VOL? (Select three.) A. S-VOLs are updated asynchronously. B. An S-VOL is a secondary or mirrored volume.

www.Prepking.com

C. An S-VOL must be paired with only one P-VOL. D. An S-VOL must be of same RAID level as its P-VOL. E. An S-VOL is always available to all hosts for read and write I/O operations. Answer: ABC 34. After a Business Copy pair is split, data are written to both the P-VOL and S-VOL. What happens during resync? A. full copy from P-VOL to S-VOL B. full copy from S-VOL to P-VOL C. delta copy from P-VOL to S-VOL D. delta copy from S-VOL to P-VOL Answer: C 35. An additional spare disk is recommended for which RAID level? A. 2D + 2D B. 3D + 3P C. 4D + 4D D. 7D + 1P Answer: D 36. A customer requires 24x7x365 uptime. Which statement describes upgrading the XP24000 microcode without losing host connectivity or I/O? A. Dual paths to the XP are necessary. B. Auto Path or Secure Path failover software must be used. C. This cannot be done because the host or hosts must go offline. D. The CHA ports will be offline for a short duration to avoid SCSI timeouts. E. Each CHA port has a backup processor allowing single path online microcode upgrade. Answer: E 37. Which statement is true regarding data movement through the XP24000? A. Data from external storage arrays should not be cached. B. LUNs from external storage arrays are connected through the CSW cache switches. C. LUNs from external storage arrays are accessed through the FSW back end switches. D. External hosts and external storage arrays attach to the XP24000 through front end CHA ports. Answer: D 38. What is an important design consideration when configuring an XP array? A. Inadequate cache causes poor random performance. B. Inadequate number of CHA ports can cause poor sequential performance. C. Inadequate SCSI queues on the server can cause poor overall performance.

www.Prepking.com

100% Pass Guaranteed or Full Refund Word to Word Real Exam Questions from Real Test Buy full version of exam from this link below http://www.prepking.com/HP0-J10.htm