Vous êtes sur la page 1sur 6

6 - 38 GHz CEPT digital hierarchy

TRuepoint
a new generation of point-to-point PDH / SDH / Ethernet digital radios

The TruePoint series is a family of compact, versatile point-to-point digital radios that provide highly reliable communication links for NxE1, STM1 and data
over a wide range of frequency bands from 6 GHz through to 38 GHz.

These radios, built on a common platform, offer a wide variety of network capacities and configurations. TRuepoint incorporates a scalable design using plugand-play modules available with traditional circuitswitched and IP interfaces. This provides users with the flexibility to choose a system that meets current needs, and the ability to easily expand the system to accommodate future growth. It reduces capital and operating expenditures commonly associated with field installation, maintenance, training and spares. TRuepoint's RF units (installed outdoors) are capacity-independent, while its signal processing units (installed indoors) are frequency-independent. TRuepoint has software-enabled features, allowing users to select capacities, modulation levels, RF frequency channels and transmit output power settings to meet worldwide regulatory and spectrum efficiency requirements. Sophisticated in-service performance monitoring and built-in diagnostics assess signal quality and identify possible path and/or hardware failures. Status LEDs on each module provide visual system alarm indications. TRuepoint can be managed and monitored using any SNMP-based network or element manager.

TRuepoint 6 - 38 GHz CEPT digital hierarchy

Ease of Use
Installation The Signal Processing Unit occupies a single rackmounting space for 1+0 configurations; two rack mounting spaces for 1+1 and 2+0 configurations. The Radio Frequency Unit is weatherproof for outdoor installation, but it can also be mounted indoors on a radio relay rack. The RFU can be attached directly to the antenna (RFU-detachable configuration). Management and Maintenance No downtime during module swaps in 1+1 configurations. The controller board can be removed without interrupting traffic. Backwards-compatible with Harris MicroStar radios through an integrated HDLC port. Intuitive LED displays on each unit indicate activity and alarm status. Built-in self diagnostics differentiate path alarms from equipment alarms. Convenient setup, monitoring and configuration of any radio in the network through a graphical web CIT, VT-100 computer terminal or hand-held keypad (provided by Harris). A removable MMC in the controller board stores software and configuration settings, which allows for autoconfiguration. Scalable The scalable, RF-independent Signal Processing Unit uses optional plug-in modules to accommodate a wide variety of data interfaces for PDH, SDH and IP applications. The Radio Frequency Unit is capacity-independent. Single module swap for capacity upgrade from 2 E1 to STM-1. The indoor configuration of the Radio Frequency/ Signal Processing Unit (TRuepoint 5300) accommodates high power amplifiers.

Flexible Software-selectable modulation (4, 16, 32, 64, 128, 256 QAM). Flexible forward error correction schemes optimize bandwidth and system gain. Plug-and-play modules facilitate faster network startup, simple reconfigurations and capacity upgrades. Reliable A common platform and integrated design for all configurations provides more than 20 years MTBF. Automatic transmitter power control (ATPC). Reverse channel switching protects against silent transmitter failures.

Key Features Also Include:


Centralized SNMP-based management system enables operators to conveniently set administrative functions, monitor performance, perform routine tasks and manage each radio in the network. Graphical, web-enhanced interface automatically monitors the network and provides access to any radio in the network. Dynamic bandwidth allocation from/within the auxiliary data channels. Standard asynchronous data transfer of 19.2 Kbps (controller board). Auxiliary plug-in slots for: - 64 Kbps synchronous, G.703 or V.11 interface - VF channel/orderwire - Additional relay inputs and alarms - Optional 10BASE-T over 64 Kbps, point-to-point

TRuepoint 6 - 38 GHz CEPT digital hierarchy

Modularity of the SPU (Signal processing Unit)


TRuepoin t ADM TRuepoint

TRuepoint

2 STM-1

Function-oriented modules minimize the need for complete board sparing. There are four main functions. - Modem/Power Supply - Multiplex - Controller - Ancillary or Service Channel (2 slots allocated) The variety of configurations available simplifies migration to higher capacities. The modem, controller, and ancillary boards are common throughout the product portfolio which reduces the need for spares, and simplifies training and maintenance. The multiplexer manages several capacites and interfaces, including the following: - 2 to 16 E1 - E3+1E1 or 2 x 100BASE-T + 1 E1 over 34 Mbps + 1 E1, - 21 E1, STM-1 partially filled - STM-1 + E1 wayside - Mixed interfaces such as 2 x 100 BASE-T with E1 (up to 16 E1), with a maximum airlink payload of 4 E3 + 2 E1. The airlink payload and traffic assignment is selectable by software. - 2 x 100BASE-T over STM-1 capacity +1 E1. - 2 or 4 E3 + 2 E1 2 x 100BASE-T payload structure. In applications using 100BASE-T LAN, the routing capability allows for port base VLAN.

SDH RING 2+0 (dual frequency)

TRuepoint

2 STM-1

TRuepoint

TRuepoint

TRuepoint

ADM

TRuepoint

SDH Linear Spur

Core Network

STM-1 (3 VC3) TRuepoint

TRuepoint

ADM

STM-1 (VC3-1)

1 E1 TRuepoint TRuepoint 21 E1

TRuepoint

21 E1/SDH-STM0
TRuepoint 1 E1 TRuepoint TRuepoint 21 E1

1 E1 TRuepoint 21 E1 TRuepoint

STM-1 (1 VC3)

ADM

Core Network

ADM

STM-1 (1 VC3)

1 E1 TRuepoint TRuepoint 21 E1

STM-1 (VC3-2) ADM

Multiplexing section K1, K2

Multiplexing section K1, K2

STM-1 (VC3-3) TRuepoint

The 21 E1 Mux is mapped into either a STM0 or a partially filled STM-1 and the Mux board behaves with the ADM to which it is connected as a multiplexing section.

2 x 100BASE-T / STM-1
2 x 100BASE-T LAN E1 TRuepoint TRuepoint STM-1 (3 VC3) STM-1 (3 VC3) 2 x 100BASE-T LAN TRuepoint TRuepoint E1

1 E1 TRuepoint 21 E1

ADM/ Router

Core Network

ADM/ Router

PABX

Multiplexing section K1, K2

Multiplexing section K1, K2

PABX

TRuepoint 6 - 38 GHz CEPT digital hierarchy

RFU Configurations
TRuepoint 5100 (13 - 38 GHz)
Unprotected (1+0) Protected (1+1)

TRuepoint (6 - 11 GHz)

Unprotected Terminal Integrated Flat Antenna Detachable RFU with Parabolic Antenna Separate Parabolic Antenna Integrated Flat Antenna Detachable RFU with Parabolic Antenna Separate Parabolic Antenna

TRuepoint 5200 (6 - 11 GHz)


Repeater Terminal

Protected Terminal

Separate Antenna

Detachable RFU with Separate Antenna

RFU

Protected

Protected

RFU

Unprotected

Protected Repeater

SPU Unprotected (1+0)

SPU Protected (1+1)

TRuepoint 6 - 38 GHz CEPT digital hierarchy

Channel Spacing (Other channel spacings are available. Consult Harris.)


Capacity 2 E1 4 E1 8 E1 16 E1 E3 + 1E1 21 E1/STM0 STM-1 (partially filled) Modulation States 4 4 16 4 16 4 16 4 16 4 16 32 32 STM-1 + 1E1 64 128 Lower Upper 6 GHz 6 GHz * * * * * * * * * * 29.65 * * 29.65 * * * * * * * * * * 20 * 40 30 7 GHz 3.5 7.0 3.5 14 7.0 28 14 28 14 * 28 14 28 8 GHz 3.5 7.0 3.5 14 7.0 28 14 28 14 * 28 14 28 10.5 GHz 3.5 7.0 3.5 14 7.0 28 14 28 14 * 28 14 28 11 GHz 40 20 * 40 13 GHz 3.5 7.0 3.5 14 7.0 28 14 28 14 * 28 14 28 14 GHz * * * * * * * * * * * * * * * 15 GHz 3.5 7.0 3.5 14 7.0 28 14 28 14 56 28 14 56 28 18 GHz 3.5 7.0 3.5 13.75 7.0 27.5 13.75 27.5 13.75 55 28 13.75 55 27.5 23 GHz 3.5 7.0 3.5 14 7.0 28 14 28 14 56 28 14 56 28 26 GHz 3.5 7.0 3.5 14 7.0 28 14 28 14 56 28 14 56 28 28 GHz 3.5 7.0 3.5 14 7.0 28 14 28 14 56 28 14 56 28 32 GHz 3.5 7.0 3.5 14 7.0 28 14 28 14 56 28 14 56 28 38 GHz 3.5 7.0 3.5 14 7.0 28 14 28 14 56 28 14 56 28

Guaranteed Receiver Threshold dBm (BER 10-6)


Capacity 2 E1 4 E1 8 E1 16 E1 E3 + 1E1 21 E1/STM0 STM-1 (partially filled) Modulation States 4 4 16 4 16 4 16 4 16 4 16 32 32 STM-1 + 1E1 64 128 Lower Upper 6 GHz 6 GHz * * * * * * * * * * -79.5 * -74.5 -70.0 * * * * * * * * * * -79.5 -77.5 -74.5 -70.0 7 GHz -94.0 -91.0 -87.0 -88.0 -84.5 -85.5 -81.5 -85.0 -81.0 * -79.5 -77.5 -69.0 8 GHz -94.0 -91.0 -87.0 -88.0 -84.5 -85.5 -81.5 -85.0 -81.0 * -79.5 -77.5 -69.0 10.5 GHz -94.0 -91.0 -87.0 -88.0 -84.5 -85.5 -81.5 -85.0 -81.0 * -79.5 -77.5 -69.0 11 GHz -83.5 -79.5 * -74.5 13 GHz -92.0 -89.0 -85.5 -86.5 -82.5 -83.5 -79.5 -83.0 -79.0 * -77.5 -75.5 -67.5 14 GHz * * * * * * * * * * * * * * * 15 GHz -92.0 -89.0 -85.5 -86.5 -82.5 -83.5 -79.5 -83.0 -79.0 -81.5 -77.5 -75.5 -75.0 -67.5 18 GHz -92.0 -89.0 -85.5 -86.5 -82.5 -83.5 -79.5 -83.0 -79.0 -81.5 -77.5 -75.5 -75.0 -67.5 23 GHz -92.0 -84.5 -85.5 -86.5 -82.5 -83.5 -79.5 -83.0 -79.0 -81.5 -77.5 -75.5 -75.0 -67.5 26 GHz -92.0 -84.5 -85.5 -86.5 -82.5 -83.5 -79.5 -83.0 -78.0 -81.5 -77.5 -75.5 -75.0 -67.5 28 GHz -92.0 -89.0 -85.5 -86.5 -82.5 -83.5 -79.5 -83.0 -79.0 -81.5 -77.5 -75.5 -75.0 -67.5 32 GHz -92.0 -89.0 -85.5 -86.5 -82.5 -83.5 -79.5 -83.0 -79.0 -81.5 -77.5 -75.5 -75.0 -67.5 38 GHz -91.5 -89.0 -85.0 -86.0 -82.0 -83.0 -79.0 -82.5 -76.5 -81.0 -77.0 -75.0 -74.5 -67.0

Nominal** Output Power (dBm)


Capacities 2 E1 4 E1 8 E1 16 E1 E3 + 1E1 21 E1/STM0 STM-1 (partially filled) Modulation States 4 4 16 4 16 4 16 4 16 4 16 32 32 STM-1 + 1E1 64 128 Lower Upper 6 GHz 6 GHz * * * * * * * * * * 27.5 26.5 25 24 * * * * * * * * * * 27.5 26.5 25 24 7 GHz 30.5 30.5 26.5 30.5 26.5 30.5 26.5 30.5 26.5 * 26.5 25.5 23 8 GHz 30.5 30.5 26.5 30.5 26.5 30.5 26.5 30.5 26.5 * 26.5 25.5 23 10.5 GHz 28.5 28.5 24.5 28.5 24.5 28.5 24.5 28.5 24.5 * 24.5 23.5 21 11 GHz 28.5 24.5 * 22 13 GHz 26 26 23 26 23 26 23 26 23 * 23 22
-

14 GHz * * * * * * * * * * * * * * *

15 GHz 26 26 23 26 23 26 23 26 23 26 23 22 22 20

18 GHz 26 26 23 26 23 26 23 26 23 26 23 22 22 20

23 GHz 25 25 22 25 22 25 22 25 22 25 22 21 21 18

26 GHz 24 24 21 23 20 23 20 23 20 24 21 20 20 17

28 GHz 24 24 21 24 21 24 21 24 21 24 21 20 20 17

32 GHz 20 20 17 20 17 20 17 20 17 20 17 16 16 13

38 GHz 24 24 21 24 21 24 21 24 21 24 21 20 20 17

20

* Available on request - Not available **Nominal power for outdoor systems from 6-11 GHz and 23-38 GHz, tolerance is + 2dB. Nominal power for 13-18 GHz outdoor systems, tolerance is +2/-1 dB. Nominal power for indoor systems, tolerance is +1 dB.

TRuepoint 6 - 38 GHz CEPT digital hierarchy System Characteristics


Band Frequency Range Xmtr/Rcvr Frequency Spacing Channel Spacing Flange for Separate Waveguide Antenna (flanges must 1,2 be specified at ordering) IEC EIA or US Mil PDR 70 PDR 70 PDR 70 PDR 84 PDR 84 PDR 100 PDR 100 PBR 120 PBR 140 PBR 140 PBR 220 PBR 220 PBR 220 PBR 320 PBR 320 PBR 320 PBR 320 PBR 320 CPR 137G CPR 137G CPR 137G CPR 112G CPR 112G CPR 90G CPR 90G UG Choke UG 541A/U UG 541A/U UG 596A/U UG 596A/U UG 596A/U UG 600A/U UG 600A/U UG 600A/U UG 600A/U UG 600A/U WR 137 WR 137 WR 137 WR 112 WR 112 WR 90 WR 90 WR 75 WR 62 WR 62 WR 42 WR 42 WR 42 WR 28 WR 28 WR 28 WR 28 WR 28

LL6 GHz L6 GHz U6 GHz 7 GHz 8 GHz 10 GHz 11 GHz 13 GHz 14 GHz 15 GHz 18 GHz 23 GHz 26 GHz 28 GHz 31 GHz 32 GHz 38 GHz 39 GHz

5,670 - 6,170 MHz 5,925 - 6,425 MHz 6,425 - 7,125 MHz 7,110 - 7,900 MHz 7,900 - 8,500 MHz 10,500 - 10,680 MHz 10,700 - 11,700 MHz 12,750 - 13,250 MHz 14,200 - 14,500 MHz 14,400 - 15,350 MHz 17,700 - 19,700 MHz 21,200 - 23,600 MHz 24,500 - 26,500 MHz 27,500 - 29,500 MHz 31,000 - 31,300 MHz 31,800 - 33,400 MHz 37,000 - 39,500 MHz 39,500 - 40,500 MHz

266 MHz 240, 252.04 MHz 340, 345 (China) MHz 151.614, 154, 160, 161, 182, 196, 245 MHz 119, 126, 208, 213.5, 266, 310, 311.32 MHz 65, 84 (France), 91 (Argentina) 490, 530 MHz 266 MHz Contact Harris 315, 322, 420, 490, 640, 644, 728, MHz 120, 340, 1008, 1010, 1092.5, 1120, 1560, 1615 MHz 252 (France), 1008, 1232, MHz 1008 MHz 1008 MHz 140 MHz 812 MHz 700 (Argentina), 980, 1260, MHz 462, 980 MHz

28 MHz 28 (Bosnia), 29.65, 40 MHz 20, 40 MHz 3.5, 7, 14, 28 MHz 7, 14, 28, 29.65 MHz 3.5, 7, 14, 28 MHz 20 (China), 40 MHz 3.5, 7, 14, 28 MHz Contact Harris 3.5, 7, 14, 28, 56 MHz 3.5, 7, 13.75, 27.5, 55 MHz 3.5, 5 (Brazil), 7, 14, 28, 56 MHz 3.5, 7, 14, 28, 56 MHz 3, 5, 7, 14, 28, 56 MHz 3.5, 7, 14, 28 MHz 3.5, 7, 14, 28, 56 MHz 3.5, 7, 14, 28, 56 MHz 3.5, 7, 14, 28, 56 MHz

(1) On request, TruePoint 5200 in the 13 to 23 GHz frequency band can be provided. Antenna flanges are CBR or equivalent US Mil. Flanges to be specified at the time of ordering. (2) The radio flanges have threaded holes to mate with the waveguide or flextwist flange through-holes. (3) The TRuepoint 5300 can accommodate an optional HPA.

TRuepoint 5100

TRuepoint 5200 & 5300 3

Bit Rate Capacity: Modulation: FEC:

2, 4, 8, 16 E1, E3+1E1, 21 E1, STM-1+1E1

detection) Power Consumption: (SPU+RFU for high capacity) Non-Protected Protected TRuepoint 5100 70 Watts 140 Watts TRuepoint 5200 80 Watts 160 Watts TRuepoint 5300* 91 Watts 182 Watts * Without HPA

4, 16, 32, 64, 128, 256 QAM

Low/Medium Capacity: Reed-Solomon High capacity: Reed-Solomon concatenated with 2D or 4D (Dimensional) TCM (Trellis Code Modulation) depending on bandwidth and system gain requirement

Digital Interfaces: E1 (75 or 120 ohms), E3 (75 ohms), STM0/STM-1 (75 ohms, OMM: Optical Multimode, OSM; Optical Single Mode), 10BASE-T, 100BASE-T Frequency Source: All RFUs are tunable within the full frequency range of all bands except the 18/23/26/32/38 GHz bands which are split into two bands Frequency Stability: 6 - 38 GHz; 5 ppm including aging Auxiliary Channels: Standard: Service Channel 1; 19.2 kbps asynchronous (RS-232) Optional: Service Channels 2 and 3 Orderwire or Data Channel 64 kbps synchronous co-contra directional V.11 or G.703 Configurations: TRuepoint 5300 & 5200 TRuepoint 5100 1+0, 1+1 (MHSB, FD, SD), 2+0, 3+0, 4+0, 2+2 (SD), 3+3 (SD), 4+4 (SD). 1+0, 1+1 (MHSB, SD), 2+0.

Regulatory Information
Frequency Plans: recommendation Digital Interface:

According to each relevant ITU-R and CEPT Rec. G.703 (E1, E3, STM-1p, STM-1)

Electromagnetic Compatibility: EN 301 489-4, EN 301 489-1 Standard: Complies with the latest ETSI and R&TTE directive and future European Harmonized EN 302 317-2-2 Class 2 type equipment operating in non-harmonized frequency bands.

Mechanical Characteristics
Connections: SPU Dimensions: SPU 1+0 SPU 1+1 TRuepoint 5100 TRuepoint 5200 TRuepoint 5300

Network Management: FarScanTM, StarView, NetBossTM, SNMP Manager Radio Control Monitoring Tools: Web CIT, VT-100, Harris Handheld Terminal, NMS Alarms: Programmable relay alarms, 4 basic relays, 2 input (controller) Optional: 12 relays/12 inputs or 6 relays/30 inputs or a combination using two Relay & Alarm modules Operating Temperature Range: Guaranteed Performance: Operational: Humidity: 95% max Indoor Outdoor 0 to +50 C -33 to +55 C -10 to +55 C -40 to +55 C

to RFU, coaxial cable with N-Type Height Width Depth 45 mm 483 mm 258 mm 90 mm 483 mm 258 mm 352 mm 241 mm 120 mm 442 mm 260 mm 300 mm 489 mm 436 mm 300 mm

connectors Weight 3.3 kg. 5.2 kg. 6.1 kg. 18 kg. 51 kg.

Antenna Characteristics
Integrated Flat Antenna: (using unique Harris Flat antenna) 23/26 GHz 16.5" (419 mm) 35 dBi 38 GHz 12.0" (305 mm) 38 dBi Detachable RFU With Parabolic Antenna: Parabolic high-performance antenna from 1 ft. to 4 ft. (30cm to 1.2m) depending on frequency band. Complies with EN 302 317-4-2. (Uses a direct slip fit with latches for connecting to the antenna.) Separate Antenna: Off-the-shelf parabolic antenna from any vendor. (Uses waveguide or flex twist to interconnect radio and antenna. Radio flange interfaces are specified in the table above.)

Power Source: 21.6 to 60 Vdc negative or positive ground (auto

Unless otherwise indicated, nominal performance specifications are listed and apply to transmitters/receivers connected back-to-back and must be confirmed before they become applicable to any specific system, contract or order.

Microwave Communications Division | 3 Htel de Ville | 3 Htel de Ville | Montral, Qubc, Canada H9B 3G4 Phone 1-800-4-HARRIS ext. 3209 (within North America) 1-407-727-9207 ext.3209 (outside North America) www.harris.com
Copyright 2003 Harris Corporation Data subject to change without notice. Printed in Canada, 10/14/03 Form 194C-2