Vous êtes sur la page 1sur 2

R.R.

Moore
The R. R. Moore, recognized as the standard for rotating beam fatigue testing, has been serving the industry faithfully for more than 75 years. Over that time the system, which features a rugged cast aluminum frame and heavy duty bearing housings, has demonstrated unsurpassed quality in machine design.

Rotating Beam Fatigue Testing System

Theory of Operation
Based on the rotating beam principle, the specimen functions as a simple beam, symmetrically loaded at two points. When rotated one half revolution, the stresses in the bers originally below the neutral axis are reversed from tension to compression and vice versa. Upon completing the revolution, the stresses are again reversed so that during one revolution the test specimen passes through a complete cycle of exural stress (tension and compression).

Features
Standard machine operates at an adjustable speed of 500 to 10,000 RPM. Speed stability is 2% of setpoint assuming a constant line voltage. Speed will change proportionally to line voltage. A voltage stabilizer is available as an option to minimize brief voltage uctuations. At the nominal rate of 10,000 RPM, the R. R. Moore completes 600,000 cycles per hour (14,400,000 cycles per day). Integrated variable speed control provides the machine capability to operate at speeds from 500 to 10,000 RPM. Speed control is important in testing certain alloys that heat up when highly stressed. It also allows certain correlations of results between high speed tests and previous lower speed tests. An easy-to-read digital cycle counter with magnetic pickup device provides an accurate display of completed cycles in display increments of 1 cycle per count up to 99,999,999 counts. Push button controls are provided to reset the display count at the start of a test. Display is equipped with a battery back-up so that count data is not lost in the event of power failure. Interlocked clear Lexan test space enclosure prevents machine operation until closed to prevent operator injury Conforms to DIN 50113 and ISO 1143 standards.

Specimen Loading
Products for Materials Testing The R. R. Moore machine can be equipped to test either straight shank or tapered-end specimens. The standard specimen length is 3-7/16 in (87.3 mm). Specimens approximately 1 in (25.4 mm) longer or shorter can be used without affecting the calibration of the machine. Straight shank specimens are held in place using precision specimen collets. Tapered-end specimens are machined to match the tapers within spindles of the machine and held in place using threaded drawbars. To ensure precision, stress is applied to the specimen by direct application of deadweights. Maximum ber stress in a specimen having a 0.300 in (7.62 mm) diameter is 75,000 psi (517 Mpa). By decreasing the diameter, the value of the maximum ber stress can be increased.
www.instron.com

R.R. Moore | Rotating Beam Fatigue Testing System

Specications
RRM-A1
Bending Moment Capacity Capacity Increments Rotational Speed in-lb kg-cm in-lb kg-cm RPM 20 - 200

RRM-A2
25 - 230 0.254 500 - 10,000
Radius: 3.5 to 10 in (88.9 to 254 mm) Maximum Diameter: 0.3 in (7.62 mm)

0.2 500 - 10,000 (8) 10, (1) 5, (2) 2, (1) 1, (1) 0.5, (2) 0.2, (1) 0.1 10 90 41 240 110 39 13 20 990 330 510 100 -120 50/60

60

lb Load Weight Set kg lb kg lb kg lb kg in mm V Hz

(7) 5, (2) 2, (1) 1, (1) 0.5, (1) 0.2, (2) 0.1, (2) 0.05 5 90 41 240 110 39 13 20 990 330 510 100 - 120 50/60 Tapered-end specimen
Taper: 0.625 in/ft (52 mm/m) Relief: 0.01 in (0.254 mm) 3.4375 in (87.312 mm) 0.481 in (12.217 mm)

Mimimum Effective Weight Machine Weight4 Shipping Weight5 Nominal Shipping Dimensions5 (h d w) Power Requirement6

Fillet Radius: 3.5 to 10 in (88.9 to 254 mm) Maximum Diameter: 0.3 in (7.62 mm) Diameter: See RRM-C1 Collet Selections

Notes: 1. Speed regulation accuracy 2% 2. Includes open-end wrench and allen wrenches for machine operation 3. Of yoke and weight pan 4. Does not include loading weights 5. Does not include optional stand (RRM-D1) but does include standard weight set 6. Transformer can be optionally supplied to step down 200 V to 240 V power

0.75 in (19.05 mm) 3.4375 in (87.312 mm)

0.75 in (19.05 mm)

Straight shank specimen

Optional Accessories
RRM-B1A RRM- C1 RRM-C1A RRM-C1B RRM-C1C RRM-C1D Standard 100-120 V Single Phase 50/60 Hz Operating Voltage (Optional 240 Volt and Conditioning Transformers Available) Set of two drawbars providing machine with the capability to accept the spring type couplings, which are used when testing straight shank specimens. Set of two precision collets for 0.240 in (6.1 mm) diameter straight shank specimens Set of two precision collets for 0.300 in (7.62 mm) diameter straight shank specimens Set of two precision collets for 0.365 in (9.27 mm) diameter straight shank specimens Set of two precision collets for 0.370 in (9.4 mm) diameter straight shank specimens Accessory set for tapered end specimens. Set includes: Set of two drawbars for tapered-end specimens Specimen extractor bolt Ring gauge for verication of proper specimen preparation Tapered end alignment verication specimen Specially designed equipment stand measures 36 24 36 in (915 610 915 mm) Includes leveling feet with vibration isolators. Furnace system for R. R. Moore machine

RRM-C2

RRM-D1 RRM-FUR

Notes: 1. A minimum of one set of specimen collets must be ordered with the RRM-C1 option to have a complete functional system. 2. When sold with the equipment stand (RRM-D1), shipping dimensions for the R. R. Moore system are 52.5 43.5 55 in (1335 1105 1400 mm) and shipping weight is 218 kgs (480 lbs).

www.instron.com
Worldwide Headquarters 825 University Ave, Norwood, MA 02062-2643, USA Tel: +1 800 564 8378 or +1 781 575 5000 European Headquarters Coronation Road, High Wycombe, Bucks HP12 3SY, UK Tel: +44 1494 464646 Instron Industrial Products 900 Liberty Street, Grove City, PA 16127, USA Tel: +1 724 458 9610

Instron is a registered trademark of Illinois Tool Works Inc. (ITW). Other names, logos, icons and marks identifying Instron products and services referenced herein are trademarks of ITW and may not be used without the prior written permission of ITW. Other product and company names listed are trademarks or trade names of their respective companies. Copyright 2010 Illinois Tool Works Inc. All rights reserved. All of the specications shown in this document are subject to change without notice. POD_RRMoore_rev7_0210