Vous êtes sur la page 1sur 4

HVAC EQUIPMENT

Boilers

Peerless Boiler OEM Replacement Parts


All of the core replacement parts and more for
Peerless Boilers are available at your Local
Johnstone Supply. Contact us for model to part

cross reference and solve your no heat and


warranty service calls fast and efficiently
with the exact OEM replacement part

Bimini Gas Fired Hot Water Boilers


Condensing, High Efficiency, Direct Spark

3/4" boiler drain


Combination temperature/pressure gauge
A.S.M.E. relief valve (30 PSI)
Stainless steel burner
Variable-speed blower assembly
Differential pressure switch for proving
air flow
Probe style LWCO
Micro processor control module
L97-827 uses 60/100mm concentric vent
L99-401 through L99-403, L90-545 and
L90-546 are commercial boilers

L99-401 through L99-403, L90-545 and


L90-546 meet Z21.3 requirements and
approved for closet installation
L90-547 through L90-554 has CPVC/PVC
venting
BWC070 through BWC120 and BWC151
models are wall mounted models with
concentric venting or CPVC/PVC venting
options
BWC150 and BWC225 are floor standing
models

Fig. Order #

Mfg. #

Gas Type Sections

AFUE

BtuH Input

DOE Htg.
Capacity
BtuH

A
A
A
A
B
B
C
C
C
A
A
A
A
B
B
C
C
A
A
A
A
A
A
A
A

BWC070
BWC090
BWC120
BWC151
BWC150
BWC225
BWC300
BWC399
BWC425
BWC070ELST1PSU
BWC090ELST1PSU
BWC120ELST1PSU
BWC151ELST1PSU
BWC150ELST1PSU
BWC225ELST1PSU
BWC300ELST1PSU
BWC425ELST1PSU
BWC070ENVT1PSU
BWC070ELVT1PSU
BWC090ENVT1PSU
BWC090ELVT1PSU
BWC120ENVT1PSU
BWC120ELVT1PSU
BWC151ENVT1PSU
BWC151ELVT1PSU

NG
NG
NG
NG
NG
NG
NG
NG
NG
LP
LP
LP
LP
LP
LP
LP
LP
NG
LP
NG
LP
NG
LP
NG
LP

95.4
94.5
95.2
95.2
93.1
94.2
95.7
96.1
96.1
95.4
94.5
95.2
95.2
93.1
94.2
95.7
96.1
95.4
95.4
94.5
94.5
95.2
95.2
95.2
95.2

70,000
90,000
120,000
150,000
150,000
225,000
300,000
399,000
425,000
70,000
90,000
120,000
150,000
150,000
225,000
300,000
425,000
70,000
70,000
90,000
90,000
120,000
120,000
150,000
150,000

63,000
80,000
107,000
135,000
135,000
202,000

63,000
80,000
107,000
135,000
135,000
202,000

63,000
63,000
80,000
80,000
107,000
107,000
135,000
135,000

L98-262
L98-263
L97-827
L99-459
L97-828
L97-829
L99-401
L99-402
L99-403
L90-539
L90-540
L90-541
L90-543
L90-542
L90-544
L90-545
L90-546
L90-547
L90-548
L90-549
L90-550
L90-551
L90-552
L90-553
L90-554

568

Mono Block
Mono Block
Mono Block
Mono Block
3
4
5
7
7
Mono Block
Mono Block
Mono Block
Mono Block
3
4
5
7
Mono Block
Mono Block
Mono Block
Mono Block
Mono Block
Mono Block
Mono Block
Mono Block

IBR Rating Flue


BtuH
Diam. Width

Height

Depth

Wt. Lbs.

Energy Star

55,000
70,000
93,000
117,000
117,000
176,000
230,000
304,000
320,000
55,000
70,000
93,000
117,000
117,000
176,000
230,000
320,000
55,000
55,000
70,000
70,000
93,000
93,000
117,000
117,000

31-1/2"
31-1/2"
31-1/2"
43-3/4"
43-3/4"
43-3/4"
24"
24"
24"
31-1/2"
31-1/2"
31-1/2"
43-3/4"
43-3/4"
43-3/4"
24"
24"
31-1/2"
31-1/2"
31-1/2"
31-1/2"
31-1/2"
31-1/2"
43-3/4"
43-3/4"

17"
17"
17"
22-1/4"
22-1/4"
22-1/4"
51-1/2"
51-1/2"
51-1/2"
17"
17"
17"
22-1/4"
22-1/4"
22-1/4"
51-1/2"
51-1/2"
17"
17"
17"
17"
17"
17"
22-1/4"
22-1/4"

143
143
149
168
285
323
438
534
535
143
143
149
168
285
323
438
535
143
143
143
143
149
149
168
168

Y
Y
Y
Y
Y
Y

Y
Y
Y
Y
Y
Y

Y
Y
Y
Y
Y
Y
Y
Y

3"
4"
4"
5"
5"

3"
4"
4"
5"

17-7/8"
17-7/8"
17-7/8"
23-3/8"
23-3/8"
27"
33-3/8"
40-1/8"
40-1/8"
17-7/8"
17-7/8"
17-7/8"
23-3/8"
23-3/8"
27"
33-3/8"
40-1/8"
17-7/8"
17-7/8"
17-7/8"
17-7/8"
17-7/8"
17-7/8"
23-3/8"
23-3/8"

List prices subject to change. Contact your local Johnstone Supply for competitive prices.

HVAC EQUIPMENT

Boilers

Concentric Vent Components for BWC Series


Adapter kit L44-618 is required for
concentric venting with model BWC150

Adapter kit L44-619 is required for


concentric venting with model BWC 225

Order #

Mfg. #

Description

Wt. Lbs.

Order #

Mfg. #

Description

Wt. Lbs.

L44-618
L44-619
L44-620
L44-621
L44-622
L44-623
L44-624
L44-625
L44-626
L80-306
L80-307
L80-308
L80-309
L80-310
L80-311
L80-312
L99-229
L99-230

230550
230555
230507
230508
230526
230527
230537
230565
230566
230506
230515
230517
230525
230531
230560
230564
230504
230505

BWC150 Vent Adapter Concentric Adapter Kit


BWC225 Vent Adapter Concentric Adapter Kit
60/100 90 Elbow
60/100 45 Elbow
80/125 45 Elbow
80/125 90 Elbow
125mm Locking Band
100/150 45 Elbow
100/150 90 Elbow
60/100 Straight 500mm Long (19-1/2")
80/125 Straight 1,000mm Long (39")
80/125 Straight 500mm Long (19-1/2")
80/125 Straight Adjustable, Telescoping
80/125 Horizontal Terminal
100/150 Straight 500mm Long (19-1/2")
100/150 Straight Adjustable, Telescoping
60/100 Straight 2,000mm Long (78')
60/100 Straight 1,000mm Long (39")

8.10
12.35
1.75
1.50
1.75
2.50
1.00
2.00
2.30
3.00
6.25
3.50
3.75
6.15
3.80
3.60
10.50
5.50

L99-231
L99-232
L99-233
L99-234
L99-235
L99-236
L99-237
L90-081

230518
230519
230532
230561
230562
230563
230569
230595

6.25
12.25
11.25
6.50
6.50
12.00
6.60
14.00

L90-082

230585

L90-083

230586

L90-084
L90-085
L45-090
L90-086

230511
230596
230597
230510

80/125 Straight 1,000mm Long (39")


80/125 Straight 2,000mm Long (78')
80/125 Vertical Terminal
100/150 Straight 1,000mm Long (39")
100/150 Straight 1,000mm Long (39")
100/150 Straight 2,000mm Long (78')
100/150 Horizontal Terminal
BWC070/090/120/151 Concentric to CPVC/PVC
Field Conversion Vent Kit
CPVC/PVC to 60/100mm Concentric Field Conversion Vent Kit
CPVC/PVC to 80/125mm Concentric Field Conversion Vent Kit
BWC Stainless Steel Horizontal Vent Terminal
BWC150 CPVC/PVC Vent Kit
BWC225 CPVC/PVC Vent Kit
BWC 070/090/120 Adapter for Venting Stainless
Steel

7.00
9.00
15.00
16.00
1.00
15.00

Maui Gas Fired Hot Water Boilers


Wall Mounted, Sealed Combustion, Direct Vent
85% AFUE
ASME copper primary heat exchange
Integral plate heat exchanger and 3-way
valve for domestic hot water
Factory installed circular, expansion tank and
near boiling piping
Built-in bypass for flow through heat
exchanger

LED provide diagnostic information


Combi models L99-245 and L99 246 have a
domestic hot water output of 2.67 gal./min.
with a 77F rise and 2.25 gal./min. with a
90F rise
L99-247 and L99-248 are heat only models
Concentric polypropylene venting system

Order #

Mfg. #

Gas Type

AFUE

BtuH Input

DOE Htg.
Capacity BtuH

IBR Rating BtuH Width

Height

Depth

Wt. Lbs.

L99-245
L99-246
L99-247
L99-248

MWC116ENT
MWC116ELT
MWC116ENL
MWC116ELL

NG
LP
NG
LP

85
85
85
85

116,000
116,000
116,000
116,000

102,000
102,000
102,000
102,000

89,000
89,000
89,000
89,000

41-1/8"
41-1/8"
41-1/8"
41-1/8"

13-5/8"
13-5/8"
13-5/8"
13-5/8"

110
110
110
110

15-3/4"
15-3/4"
15-3/4"
15-3/4"

Aruba 3 Gas Fired Hot Water Boilers


Atmospheric, Chimney Vent
Approved for installation on non-carpeted
combustible floors
Cast iron heat exchanger
Built-in draft diverter category 1 venting
Motorized vent damper
Supply tapping located off top of boiler for
easier supply piping
1-1/4" high performance circulator
Stainless steel burners
Combination high limit/circulator relay control
Aquastat mounted directly into heat
exchanger
Order #

Mfg. #

AFUE

Standing Pilot Models


L96-582
AWI061SNST1PSU 80.0%
L96-583
AWI095SNST1PSU 80.1%
L96-584
AWI128SNST1PSU 80.2%
L96-585
AWI162SNST1PSU 80.3%
Electronic Ignition Models
L97-258
AWI061ENST1PSU 80.00%
L97-259
AWI095ENST1PSU 80.10%
L97-260
AWI128ENST1PSU 80.20%
L97-261
AWI162ENST1PSU 80.30%

Spill switch detects venting problems


ASME relief valve set at 30 PSI
Natural gas (LP gas available at participating
locations)
For altitudes above 2,000', ratings should be
reduced at rate of 4% for each 1,000' above
sea level
Boiler must be ordered for proper elevation
above sea level when being installed at
altitudes above 2,000

BtuH Input

DOE Htg.
Capacity BtuH

IBR Rating BtuH Flue Diam.

Width

Height

Depth

Wt. Lbs.

61,000
95,000
128,000
162,000

50,000
78,000
105,000
132,000

43,000
68,000
91,000
115,000

4"
5"
6"
6"

11-3/4"
15"
18-1/4"
21-1/2"

32-1/4"
32-1/4"
32-1/4"
32-1/4"

28"
28"
28"
28"

267
317
367
417

61,000
95,000
128,000
162,000

50,000
78,000
105,000
132,000

43,000
68,000
91,000
115,000

4"
5"
6"
6"

11-3/4"
15"
18-1/4"
21-1/2"

32-1/4"
32-1/4"
32-1/4"
32-1/4"

28"
28"
28"
28"

267
317
367
417

Large local inventories. More products online at johnstonesupply.com

569

HVAC EQUIPMENT
Boilers

Cabo 2 Gas Fired Hot Water Boilers


CWD Series, Sealed Combustion, Direct Spark Ignition, 85% AFUE
Approved for installation on non-carpeted
combustible floors
Ideal for tightly built and well insulated new
homes and houses without chimneys
Cast iron wet-leg heat exchanger
Direct horizontal venting or vertical venting
options to suit most locations category III
venting; see intallation instructions
Powered intake and venting
System Controller provides two zones

Plug-in outdoor temperature rest control


Self diagnostics with LED indicators
Pressure switch
Electronic ignition and step opening gas
valve
Stainless steel burners
Altitudes above 2,000' ratings should be
reduced at a rate of 4% for each 1,000'
above sea level

Order #

Mfg. #

Sections

AFUE

BtuH Input

DOE Htg.
IBR Rating
Capacity BtuH BtuH

Flue Diam.

Width

Height

Depth

Wt. Lbs.

L97-266
L97-267
L97-268
L97-269
L97-270
L97-271
L97-272
L97-273

CWD-060
CWD-083
CWD-110
CWD-138
CWD-165
CWD-193
CWD-220
CWD-245

3
4
5
6
7
8
9
10

85.1
85.1
85.2
85.2
85.2
85.2
85.2
85.3

60,000
82,500
110,000
137,500
165,000
192,500
220,000
245,000

51,000
71,000
94,000
118,000
142,000
165,000
189,000
211,000

3"
3"
3"
3"
3" or 4"
3" or 4"
3" or 4"
3" or 4"

16-1/8"
19-3/4"
23-3/8"
27"
30-5/8"
34-1/8"
32-3/4"
41-3/8"

36-5/8"
36-5/8"
36-5/8"
36-5/8"
36-5/8"
36-5/8"
36-5/8"
36-5/8"

22-1/8"
22-1/8"
22-1/8"
22-1/8"
22-1/8"
22-1/8"
22-1/8"
22-1/8"

280
315
350
385
420
475
525
580

45,000
61,000
82,000
102,000
123,000
144,000
164,000
183,000

Bali Gas Fired Hot Water Boilers


Induced Draft, Electronic Ignition
Approved for installation on non-carpeted
combustible floors
Cast iron heat exchanger
Step opening gas valve for smooth ignition
Supply tapping located off top of boiler
Integral fan for side-wall venting
Category III side-wall or vertical venting with
AL294C stainless steel venting material
May be chimney vented using optional
category I venting
Induced draft blower with pressure switch
Honeywell electronic ignition system with 30
second pre-purge
Universal vent adapter
High performance circulator with isolation
flanges
Stainless steel burners
Order #

Mfg. #

AFUE

L96-586
L96-587
L96-588

BWF061ENST1PSU 83.3%
BWF095ENST1PSU 83.1%
BWF128ENST1PSU 82.8%

Pressure switch detects venting problems


Rollout switch detects heat exchanger
blockage
Combination temperature/pressure gauge
Boiler drain
ASME relief valve set at 30 PSI
Two-tone powder coated jacket insulated
with fiberglass
Natural gas (LP gas available at participating
locations)
For altitudes above 2,000', ratings should be
reduced at rate of 4% for each 1,000' above
sea level
Boiler must be ordered for proper elevation
above sea level when being installed at
altitudes above 2,000

BtuH Input

DOE Htg.
Capacity BtuH

IBR Rating BtuH Flue Diam.

Width

Height

Depth

Wt. Lbs.

61,000
95,000
128,000

51,000
78,000
106,000

44,000
68,000
92,000

14-1/4"
17-1/2"
20-3/4"

36-11/16"
36-11/16"
36-11/16"

26-3/4"
26-3/4"
26-3/4"

282
332
382

3"
3"
3"

Tobago Cast Iron Oil Hot Water Boilers


With Front Mounted Tankless Coil for Domestic Hot Water
NOT FOR INSTALLATION ON
COMBUSTIBLE FLOORS
High efficiency to 85.8% AFUE
Two-tone powder coated jacket, resists
scratching, insulated with fiberglass to
minimize wasteful heat loss
Split top jacket panel easily removed
Higher capacities can be achieved by
changing the nozzle size
Chimney vent
Wet base construction surrounds combustion
area at top, bottom, rear and sides of boiler
Order #

Mfg. #

L96-589
L97-262
L96-590

TWZ075BOTT1PSU 3
TWZ100BOTT1PSU 3
TWZ125BOTT1PSU 4

570

Sections

Combustion chamber has a ceramic fiber


target wall with floor blanket
Swing open burner door for easy service
The BNR capacity of L96-589 is 0.75,
L97-262 is 1.0 and L96-590 is 1.25
Standard equipment includes: Oil solenoid
valve, burner twist disconnect, flame
retention oil burner with interrupted ignition,
combination aquastat/relay, draft regulator,
1-1/2" circulator, combination temperature/
pressure gauge, boiler drain valve, ASME
relief valve

AFUE

DOE Htg.
Capacity BtuH

IBR Rating BtuH

Width

Height

Wt. Lbs.

85.8
84.3
84.9

91,000
120,000
152,000

79,000
104,000
132,000

24-1/2"
24-1/2"
24-1/2"

31-1/2"
31-1/2"
31-1/2"

560
560
680

List prices subject to change. Contact your local Johnstone Supply for competitive prices.

HVAC EQUIPMENT

Boilers

Freeport CT Cast Iron Oil Hot Water Boilers


For New and Old Homes with Chimneys
Full lifetime warranty on cast iron heat
exchanger
Chimney required
Three-pass Scotch Marine design provides
full heating value
Fast response from low water content
Easily serviced with a swing open access
door

Ultra compact size


Positive pressure Beckett burner
The BNR capacity of L97-263 is 1.0 and
L97-264 is 1.35

Order #

Mfg. #

Sections

AFUE

DOE Htg.
Capacity BtuH

IBR Rating BtuH

Width

Height

Depth

Wt. Lbs.

L97-263
L97-264

CTPB-35
CTPB-45

3
4

84.7
84.0

120,000
160,000

104,000
139,000

25"
25"

26"
26"

19-1/4"
24-1/4"

443
527

Commercial Atmospheric Natural Gas Fired Hot Water or


Steam Boilers
For Businesses, Institutions, Commercial Buildings
Cast iron sections and push nipples with
stainless burners
Built-in draft hood fits under low ceilings
Modular design, shipped unassembled, for
easy installation
Optional tankless coil for domestic hot water
on water boilers
Steam boilers tapped for a Mega-Store or
Maxi-Therm indirect water heater

Available with standard or CSD-1 control


systems
Sizes from 475 to 2,850 MBH input
Note: Contact your local Johnstone Supply for
complete information on Crown Boiler Series
32 Commercial Boilers.

Indirect Water Heaters


Mega-Stor High Efficiency
Provides more gallons of water after an hour
of heating than gas, electric or oil-fired water
heaters
Stainless steel tanks and coil come with a
lifetime guarantee
Adjustable aquastat
Available from 26 to 119 gallons

Order #

Mfg. #

Gallons

Indirect Water Heaters


L97-265
MS-26
26.4
L96-356
MS-40
39.6
L96-357
MS-53
52.8
L96-358
MS-79
79.3
L96-359
MS-119
119.0
Horizontal
L99-404
MSH-40H 38
L99-405
MSH-53H 51

L99-404 and L99-405 are horizontal storage


tanks
L99-401 through L99-403 meet Z21.3
requirements and approved for closet
installation

First Hour GPH

BtuH Output

Diam.

Length

Height

Wt. Lbs.

142
166
253
253
350

110,000
120,000
164,000
190,000
386,000

20-1/4"
20-1/4"
23-7/8"
23-3/4"
29-1/4"

38-1/4"
54-3/4"
47-7/8"
69-1/4"
66"

49
77
103
204
218

151.4
202.9

75,088
100,890

34-3/4"
44-7/8"

23-7/8"
23-7/8"

24-3/8"
24-3/8"

168
193

Solar Indirect Water Heaters

Order #

Mfg. #

L99-406
L99-407

MSS-79S 76
MSS-119S 116

Gallons

Diam.

Height

Wt. Lbs.

24"
29"

68-3/4"
67"

126
210

Large local inventories. More products online at johnstonesupply.com

571

Vous aimerez peut-être aussi