Vous êtes sur la page 1sur 63

Faculty of Engineering and the Built

Environment
Department of Chemical
Engineering

Chemical Engineering Laboratory


II
CHE3049W

PRACTICAL:2
Name

Arlette Giron

Group No.

Date Completed

Practical No.

C2

17/03/2011

Date Handed-In

04/04/2011

DECLARATION
1. I know that plagiarism is wrong. Plagiarism is to use anothers work and to pretend
that it is ones own.
2. I have used the prescribed referencing system for citation and referencing. Each
significant contribution to, and quotation in, this report from the work, or works, of
other people has been attributed, and has been cited and referenced.
3. This report is my own work.
4. I have not allowed, and will not allow, anyone to copy my work with the intention of
passing it off as his or her own work.

Signature

A Giron

Synopsis
In this report it shall be shown that the efficiency of a hydrogen fuel cell can
be determined by performing chemical engineering concepts, mainly mass
and energy balances around parts of the system in consideration, in the
meanwhile demonstrating that an understanding of the hydrogen fuel cell
has been grasped effectively. The main concern of this report is to obtain
the rate law of the fuel cell through the derivation of the Butler-Vollmer
equation hence obtaining theoretical values of the electrode current which
will be use to plot polarization curves and hence determine whether the
fuel cell is functioning efficiently.

1 Contents
Synopsis
pg. 2
List of
figures
...pg.3
List of
tables
.pg.4
Nomenclature
.pg.4
Glossary
pg.4
2 Introduction
2.1.
Introduction
...pg.5
2.2. Background of
subject.pg.5
2.3.
Objectives
.pg.5
3 Literature Review
3.1. Background on fuel cell
electrochemistry..pg.5
3.2. Derivation of Butler-Vollmer
equation.pg.5
3.3. Application of Butler-Vollmer equation to Hydrogen fuel
cell..pg.7
4 Experimental plans
4.1.
Apparatus
..pg.8
4.2. Experimental setup...pg.8
4.3.
Procedure
pg.8
5 Process Flow Diagram of Hydrogen fuel cell
5.1. PFD
.
.pg.9
5.2. Reactions in the
PEMFC..pg.9
6 Mass balances around fuel
stack...pg.10
7 Energy balances surrounding cooling
systempg.11
8 Polarization
Curves
..pg.15
9 Results analysis and error
considerationspg.16
3

10
Conclusion
...pg.17
11
Recommendations
.pg.17
12
Bibliography
...pg.18
13
Appendix
..pg.19
13.1.Raw data for Mass Balances
13.2. Raw data for Energy Balances
13.3. Raw data for Rate law
13.4. Mass balance calculations
13.5. Energy balance calculations
13.6. Rate law calculations

List of Figures
Fig.1. Apparatus
Fig.2. Experimental Setup
Fig.3. PFD of process
Fig.4. Reactions in PEMFC
Fig.5. Graph of comparison of hydrogen consumtion at 5A
Fig.6. Graph of comparison of hydrogen consumtion at 10A
Fig.7. Graph of comparison of hydrogen consumtion at 15A
Fig.8. Graph of comparison of hydrogen consumtion at 19A
Fig.9. Energy bar graphs with 5% amount error bars at 5A
Fig.10. Energy bar graphs with 5% amount error bars at 10A
Fig.11 . Energy bar graphs with 5% amount error bars at 15A
Fig .12. Energy bar graphs with 5% amount error bars at 19A
Fig.13. Plot of Overpotential vs Current density
Fig.14. Polarization curves
List of Tables
Table 1. Average values of hydrogen consumption
Table.2. Regression constants of Polarization Curves
Nomenclature
4

jf :forward reaction
jb: backward reaction
kf: forward reaction rate coefficient
Cox:surface concentration of reacting species
kb: backward reaction rate coefficient
CRd:surface concentration of reacting species
kB: Boltzmanns constant
h: Plancks constant
: transfer coefficient
F: Faradays constant
E: the potential
n: number of electrons transferred
v: stoichiometric number defined as the number of times rate-determining
reaction step must occur for the overall reaction to occur once
Er: reversible equilibrium potential
Glossary
PEMFC :Proton exchange membrane fuel cell
Current density : current (of electrons or ions) per unit area of surface
(Barbir, 2005)
Exchange current density : rate at which electrons are released or
consumed in a cell. It is a measurement of the electrodes inclination to
proceed with the chemical reaction (Barbir, 2005)
Overpotential : difference between the electrode potential and the
reversible potential that is required to generate current (Barbir, 2005)
Experimental values :Data that has been obtained directly from the program
Theoretical values: Values that have been calculated using data obtained
from program

2 Introduction
2.1. Introduction
Before anything else, it is important to give insight on what exactly shall be
dealt with in this practical report. Until now the objective of the practical has
been clearly stated without a proper explanation on what exactly a
hydrogen fuel cell is and for what purpose it exists, hence the significance of
chapter 2.
2.2. Background of subject
With the ever increasing need to produce methods that enable us to obtain
more environmentally friendly sources of electrical energy,
A PEM hydrogen fuel cell is an electrochemical energy converter, which is a
device that converts chemical energy of fuel, in this case hydrogen, directly
in to electrical energy, by obeying thermodynamic laws (Barbir, 2005).
2.3. Objectives
The main objective of this practical is to determine if the fuel cell is working
properly by means of an energy balance, a mass balance and a rate law
5

calculation to determine if the experimental values of the current density


coincide with the theoretical values.
3 Literature Review
3.1. Background on fuel cell electrochemistry
From section 2 of this report it was stated that there were mainly two
reactions happening in the interface between the ionically conductive
electrolyte and electrically conductive electrode, mainly:
Anode :H22H+ +2eCathode : O2 +2H+ +2e-H2O
The rate of an electrochemical reaction is determined by an activation
energy barrier that the charge must overcome in moving from one
electrolyte to a solid electrode or vice versa. The speed at which an
electrochemical reaction proceeds on the electrode surface is the rate at
which electrons are released or consumed, which is the electrical current
(Barbir, 2005).
3.2. Derivation of Butler-Volmer equation
The forward and backward reactions are described by the following
equations:
(forward reaction) .equation 1
(backward reaction)..equation 2
Since both of these equations either release or consume electrons they can
be represented by a net current expression:
..equation 3
From the transition state theory, it was shown that the reaction rate
coefficient for an electrochemical reaction is a function of the Gibbs free
energy:

.equation 4
The Gibbs free energy for electrochemical reactions was then considered to
consist of both the chemical and electrical components of the reaction.
Hence
..e
quation 5
for the reduction reaction and

ation 6

..equ
for the oxidation reaction
6

(the subscript ch denotes the chemical component of the Gibbs free


energy)
Taking into account that in reality there are actually more than two reaction
occurring in our system, rather than the two main ones described above, it
is easier to use an experimental parameter, (the transfer coefficient) to
represent the slowest step which is in most cases the rate determining step
in chemical equilibrium situations.
Hence:
equation
7
therefore the forward and backward reaction rates are represented by
..
.equation 8

...equation 9
Finally by introducing equations 8 and 9 into equation 3 we arrive at the
new current density equation:

..equati
on 10
The rate at which the reactions proceed at equilibrium is called the
exchange current density:
..equatio
n 11
By combining equations 8 and 9 we arrive at the Butler-Volmer equation

.equa
tion 12
3.3. Application of Butler-Volmer equation to hydrogen fuel cell
The main purpose of this practical is to determine the efficiency of the
hydrogen fuel cell by applying the Butler-Volmer equation. To be able to
apply the equation we must have all the values of the terms stated in the
equation. Most of the terms are constants, such as the Faradays constant,
etc, the ox is available in literature as it is a value that doesnt vary
significantly.
As for the Rd value, it will have to be determined by the linearization of the
Butler-Volmer equation.
7

First of all, it must be taken into account that the reduction reaction is the
slowest reaction; hence it is the rate determining step and that a value of
0,5 is given to anode transfer coefficient (Barbir,2005), hence eliminating
the oxidation reaction in the Butler-Volmer equation and reducing it to the
following equation:

..equation 13
Obs: For the purpose of calculation facilitation the E-Er have been changed
to Er-E leading to:

.equation
14
(by mathematical laws will lead to the same answers).
Then by application of basic mathematical manipulation of terms in
equation and substitution of Er-E by V, V is then made the subject of the
formula:

..equ
ation 15
This equation will is then rearranged to :
V = A ln i A ln io

in which A is the
term, and when plotted and the gradient will be the
value of A which will be used to solve for the Rd value and the y intercept
will be the -Alnio and then we shall solve for the io value.
Once the Rd value and io values have been determined they will placed
back into the reduced Butler-Volmer equation and the current density
values calculated to form polarization curves and compare the theoretical
and experimental values of the current density.

4 Experimental Plans
4.1. Apparatus

Fig.1. Apparatus
4.2. Experimental Setup
Most of the work was dependent on the
software of the HP600.
Fig.2. Experimental Setup
4.3. Experimental Procedure
The practical consisted of taking data for
three purposes:
-To obtain to obtain the rate law for the fuel cell
-To be able to perform a mass balance over the fuel stack
-To be able to perform an energy balance over the cooling system
Mass and Energy Balances
1. Load was switched on and set to 5A.
2. The system was allowed to reach a steady temperature (between 3033oC).
3. Data was recorded on the computer for 60-90 seconds.
4. Following 90 seconds, recording was stopped and the data and saved.
5. Steps 2-4 were repeated for different load settings of 10A, 15A and 19A.
Rate Law
1. The system was allowed to reach a steady temperature (between 3033oC).
2. Load set to 0.2A.
3. Data recording started.
9

4. After fifteen seconds load increased by an increment of 0.2A and allowed


to run for fifteen seconds.
5. Repeat step 4 until 2A.
6. Increased the increment to 0.3A every fifteen seconds from 2A until 3.8A.
7. Increased the increment to 0.4A every fifteen seconds from 3.8A until 5A.
8. Increased the increment to 1A every fifteen seconds from 5A to 10A.
9. Lastly, increased the increment to 2A every fifteen seconds from 10A to
19A
5 Process Flow Diagram of Hydrogen fuel cell
5.1. PFD
C
o
o
l
W
a
te
r

F
a
n
S
y
s
te
m

C
o
o
lin
g
S
y
s
te
m

C
o
m
p
u
te
r
L
o
a
d

W
a
rm
w
a
te
r

C
o
o
lin
g
W
a
te
r

F
u
e
lS
ta
c
k

H
y
d
ro
g
e
n
S
o
u
rc
e

W
a
te
r

A
irw
ithO
x
y
g
e
n
S
o
u
rc
e

H
y
d
ro
g
e
n

/ A
ir

A
ir
S
o
u
rc
e

H
y
d
ro
g
e
n
P
u
rg
e

A
tm
o
s
p
h
e
re

Fig.3.PFD of process
5.2. Reactions in the PEMFC

e-e

e-e
H2
H2
H2
H2
H2
H2
H2
H2

H2
H2
H2
H2
H2
H H2
2

H2
H2
H2

Anode
Anode

H+
H+
H+
H+
H+
H+

H
H+

Electrolyte
Electrolyte

O2
O2
H2O
H2OO
H2O
H2O

O2
O2
2

O2
H2O
H2O
O2
O2

Cathode
Cathode

Fig.4. Reactions in PEMFC


In the diagram above the process happening inside the fuel cell is
demonstrated by a small illustration. Where the hydrogen enters the anode
side of the cell, is reduced and reacts with the oxygen in the cathode side
producing an electric current in such a process (exemplified by the light
bulb), with water as a byproduct.
6 Mass Balance around Fuel Stack
10

A mass balance was performed around the fuel cell stack in order to
compare the values of theoretical hydrogen consumed and experimental
hydrogen consumed.
The table below shows the average values obtained at 4 different current
values.
Table 1. Average values of hydrogen
Current Load (A)
Experimental
Consumption
(l/min)
5
1,44
10
2,30
15
2,53
19
4,17

consumption
Theoretical
Consumption
(l/min)
1,09
1,83
2,90
3,47

Error (%)
24,3
20,4
12,8
16,8

The graphs below are a comparison of the theoretical and experimental


consumptions at the different currents.

Fig.5. Graph of comparison of hydrogen consumtion at 5A

Fig.6. Graph of comparison of hydrogen consumtion at 10A

11

Fig.7. Graph of comparison of hydrogen consumtion at 15A

Fig.8. Graph of comparison of hydrogen consumtion at 19A


7 Energy Balances around Cooling System
In this section the results of the energy balance done around the cooling
system will be presented with energy bar graphs comparing the
experimental and the theoretical cooling duty.

12

Fig.9. Energy bar graphs with 5% amount error bars at 5A


Residual Plot of 5A Energy Bar Graph

13

Fig.10. Energy bar graphs with 5% amount error bars at 10A


Residual Plot of 10A Energy Bar graph

Fig.11 . Energy bar graphs with 5% amount error bars at 15A


Residual Plot of 15A Energy Bar graph

14

Fig .12. Energy bar graphs with 5% amount error bars at 19A
Residual Plot of 19A Energy Bar graph

8 Polarization Curves
This section is dedicated to the results obtained by using the reduced rate
law to obtain the Rd and io values from the following plot:

15

Fig.13. Plot of Overpotential vs Current density


As stated before the reduction transfer coefficient value (Rd) was obtained
by using the value of the slope of the best fit line and the io values by using
the value of the y intercept. Once the values were obtained they were
plugged back into the reduced Butler Volmer equation:

....
..equation 13
And the following polarization curves were plotted to compare the values of
experimental and theoretical current:

Fig.14. Polarization curves


Table.2. Regression constants of Polarization Curves
Coefficients
Standard
Lower 95%

Upper 95%
16

Error
Intercept

0,320374

0,00136

0,317703

0,323044

X Variable 1

0,106078

0,000659

0,104784

0,107373

Residual Plot

9 Results analysis and error considerations


9.1. Mass Balances
It is evident from the data collected and the mass balance done that there
are some discrepancies in the comparison between the experimental and
the theoretical amount of hydrogen consumed. Those discrepancies are
uniform throughout all of the mass balance calculations and can be justified
by the fact that the mass balance did not account for the excess hydrogen
being purged out of the system into the atmosphere.
Also the mass balances show an increase of hydrogen consumption every
time the current output was increased, this is only logical as the more
current needed the higher the hydrogen consumption.
9.2. Energy Balances
The energy balances also show some discrepancies, the highest being at
15A. It must taken into account that in our calculations the cooling done by
the cooling fan isnt taken into account. That should account therefore for
the differences between the experimental and the theoretical values of the
cooling duty, though from the relatively low errors in the values it is visible
that the cooling duty done by the cooling fan in much lower than that of the
water cooling system.
9.3. Polarization Curves
The polarization curves show that theoretical and experimental current
density values do not differ very much from one another and also that the
cathode rate law is predominant as plotting the current density values
obtained from a reduced Butler-Volmer equation is enough to obtain a
relatively accurate polarization curve.

10 Conclusions
17

From the energy balances, mass balances and polarization it has been
concluded the fuel cell is functioning properly. Though there are minor
discrepancies, such discrepancies have been accounted for.
Therefore the overall Botler-Volmer equation for the fuel cell is:

equation 16
11 Recommendations
The objectives with just one test run have been accomplished but to confirm
these results it would be advisable to repeat the experiment at least twice
more to minimize errors.
Also, it is essential that in every experiment a steady state temperature is
achieved before recording any data.

12 Bibliography
-Barbir, F., 2005, PEM Fuel Cells, 1st ed. Elseview Academic Press, San
Diego,
pp 1725, pp33 38.
- Miansari, Me., Sedighi, K., Amidpour, M., Alizadeh, E., & Miansari, Mo.,
2009, Experimental and thermodynamic approach on proton exchange
membrane fuel cell performance, Journal of Power Sources, 190(2), 356-361.
- Song, C., Tang, Y., Lu, J., Zhang, J., Wang, H., and Shen, J., 2007, PEM fuel
cell reaction kinetics in the temperature range of 23120 C, High
Temperature, 52, 2552-2561.

18

13 Appendix
13.1 Raw data for Mass Balances
Raw data for 5A

Numbe
Cur Cha r of
rent rge electro
(A) ( c) ns
7,6
0E
7,6 +0 4,74E+
0
0
19
7,8
9E
7,8 +0 4,93E+
9
0
19
7,4
0E
7,4 +0 4,62E+
0
0
19

Number
Volumetr
Numb of
Hydrogen ic
er of hydrogen flowrate
flowrate
mols mols
(mol/s)
(l/s)

Volumetri
c flow
rate
(l/min)

Hydr
ogen
cons
ump
tion
(l/mi
n)

7,88E
-05
3,94E-05

3,94E-05

9,90E-04 1,43

1,08

8,18E
-05
4,09E-05

4,09E-05

1,03E-03 1,48

1,09

7,67E
-05
3,83E-05

3,83E-05

9,64E-04 1,39

1,07
19

7,7
0
7,8
0
7,8
0
7,7
0
7,8
0
7,7
0
7,8
9
7,3
1
7,6
0
7,9
9
7,8
0
7,8
0
7,3
1
7,7

7,7
0E
+0
0
7,8
0E
+0
0
7,8
0E
+0
0
7,7
0E
+0
0
7,8
0E
+0
0
7,7
0E
+0
0
7,8
9E
+0
0
7,3
1E
+0
0
7,6
0E
+0
0
7,9
9E
+0
0
7,8
0E
+0
0
7,8
0E
+0
0
7,3
1E
+0
0
7,7

4,81E+ 7,98E
19
-05
3,99E-05

3,99E-05

1,00E-03 1,44

1,07

4,87E+ 8,08E
19
-05
4,04E-05

4,04E-05

1,02E-03 1,46

1,07

4,87E+ 8,08E
19
-05
4,04E-05

4,04E-05

1,02E-03 1,46

1,08

4,81E+ 7,98E
19
-05
3,99E-05

3,99E-05

1,00E-03 1,44

1,09

4,87E+ 8,08E
19
-05
4,04E-05

4,04E-05

1,02E-03 1,46

1,08

4,81E+ 7,98E
19
-05
3,99E-05

3,99E-05

1,00E-03 1,44

1,09

4,93E+ 8,18E
19
-05
4,09E-05

4,09E-05

1,03E-03 1,48

1,09

4,56E+ 7,57E
19
-05
3,79E-05

3,79E-05

9,52E-04 1,37

1,08

4,74E+ 7,88E
19
-05
3,94E-05

3,94E-05

9,90E-04 1,43

1,07

4,99E+ 8,28E
19
-05
4,14E-05

4,14E-05

1,04E-03 1,50

1,07

4,87E+ 8,08E
19
-05
4,04E-05

4,04E-05

1,02E-03 1,46

1,09

4,87E+ 8,08E
19
-05
4,04E-05

4,04E-05

1,02E-03 1,46

1,09

4,56E+ 7,57E
19
-05
3,79E-05
4,81E+ 7,98E 3,99E-05

3,79E-05
3,99E-05

9,52E-04 1,37
1,00E-03 1,44

1,09
1,07
20

0
7,4
0
7,7
0
7,8
9
7,4
0
7,6
0
7,5
0
7,7
0
7,8
9
7,4
0
7,8
0
7,4
0
7,8
0
7,8
9

0E
+0
0
7,4
0E
+0
0
7,7
0E
+0
0
7,8
9E
+0
0
7,4
0E
+0
0
7,6
0E
+0
0
7,5
0E
+0
0
7,7
0E
+0
0
7,8
9E
+0
0
7,4
0E
+0
0
7,8
0E
+0
0
7,4
0E
+0
0
7,8
0E
+0
0
7,8
9E

19

-05

4,62E+ 7,67E
19
-05
3,83E-05

3,83E-05

9,64E-04 1,39

1,07

4,81E+ 7,98E
19
-05
3,99E-05

3,99E-05

1,00E-03 1,44

1,08

4,93E+ 8,18E
19
-05
4,09E-05

4,09E-05

1,03E-03 1,48

1,08

4,62E+ 7,67E
19
-05
3,83E-05

3,83E-05

9,64E-04 1,39

1,07

4,74E+ 7,88E
19
-05
3,94E-05

3,94E-05

9,90E-04 1,43

1,06

4,68E+ 7,77E
19
-05
3,89E-05

3,89E-05

9,77E-04 1,41

1,07

4,81E+ 7,98E
19
-05
3,99E-05

3,99E-05

1,00E-03 1,44

1,07

4,93E+ 8,18E
19
-05
4,09E-05

4,09E-05

1,03E-03 1,48

1,08

4,62E+ 7,67E
19
-05
3,83E-05

3,83E-05

9,64E-04 1,39

1,09

4,87E+ 8,08E
19
-05
4,04E-05

4,04E-05

1,02E-03 1,46

1,07

4,62E+ 7,67E
19
-05
3,83E-05

3,83E-05

9,64E-04 1,39

1,09

4,04E-05
4,09E-05

1,02E-03 1,46
1,03E-03 1,48

1,07
1,08

4,87E+
19
4,93E+
19

8,08E
-05
4,04E-05
8,18E 4,09E-05
-05

21

7,5
0
7,5
0
7,8
9
7,8
0
7,3
1
7,7
0
7,9
9
7,8
0
7,7
0
7,4
0
7,7
0
7,8
9
7,5
0

+0
0
7,5
0E
+0
0
7,5
0E
+0
0
7,8
9E
+0
0
7,8
0E
+0
0
7,3
1E
+0
0
7,7
0E
+0
0
7,9
9E
+0
0
7,8
0E
+0
0
7,7
0E
+0
0
7,4
0E
+0
0
7,7
0E
+0
0
7,8
9E
+0
0
7,5
0E
+0

4,68E+ 7,77E
19
-05
3,89E-05

3,89E-05

9,77E-04 1,41

1,09

4,68E+ 7,77E
19
-05
3,89E-05

3,89E-05

9,77E-04 1,41

1,08

4,93E+ 8,18E
19
-05
4,09E-05

4,09E-05

1,03E-03 1,48

1,08

4,87E+ 8,08E
19
-05
4,04E-05

4,04E-05

1,02E-03 1,46

1,07

4,56E+ 7,57E
19
-05
3,79E-05

3,79E-05

9,52E-04 1,37

1,10

4,81E+ 7,98E
19
-05
3,99E-05

3,99E-05

1,00E-03 1,44

1,10

4,99E+ 8,28E
19
-05
4,14E-05

4,14E-05

1,04E-03 1,50

1,08

4,87E+ 8,08E
19
-05
4,04E-05

4,04E-05

1,02E-03 1,46

1,09

4,81E+ 7,98E
19
-05
3,99E-05

3,99E-05

1,00E-03 1,44

1,09

4,62E+ 7,67E
19
-05
3,83E-05

3,83E-05

9,64E-04 1,39

1,09

4,81E+ 7,98E
19
-05
3,99E-05

3,99E-05

1,00E-03 1,44

1,08

4,09E-05
3,89E-05

1,03E-03 1,48
9,77E-04 1,41

1,09
1,09

4,93E+
19
4,68E+
19

8,18E
-05
4,09E-05
7,77E 3,89E-05
-05

22

7,5
0
7,8
9
7,6
0
7,4
0
7,7
0
7,8
0
7,5
0
7,4
0
7,8
0
7,7
0
7,8
9
7,4
0
7,8
0

0
7,5
0E
+0
0
7,8
9E
+0
0
7,6
0E
+0
0
7,4
0E
+0
0
7,7
0E
+0
0
7,8
0E
+0
0
7,5
0E
+0
0
7,4
0E
+0
0
7,8
0E
+0
0
7,7
0E
+0
0
7,8
9E
+0
0
7,4
0E
+0
0
7,8
0E
+0
0

4,68E+ 7,77E
19
-05
3,89E-05

3,89E-05

9,77E-04 1,41

1,06

4,93E+ 8,18E
19
-05
4,09E-05

4,09E-05

1,03E-03 1,48

1,10

4,74E+ 7,88E
19
-05
3,94E-05

3,94E-05

9,90E-04 1,43

1,09

4,62E+ 7,67E
19
-05
3,83E-05

3,83E-05

9,64E-04 1,39

1,07

4,81E+ 7,98E
19
-05
3,99E-05

3,99E-05

1,00E-03 1,44

1,08

4,87E+ 8,08E
19
-05
4,04E-05

4,04E-05

1,02E-03 1,46

1,08

4,68E+ 7,77E
19
-05
3,89E-05

3,89E-05

9,77E-04 1,41

1,09

4,62E+ 7,67E
19
-05
3,83E-05

3,83E-05

9,64E-04 1,39

1,07

4,87E+ 8,08E
19
-05
4,04E-05

4,04E-05

1,02E-03 1,46

1,08

4,81E+ 7,98E
19
-05
3,99E-05

3,99E-05

1,00E-03 1,44

1,08

4,93E+ 8,18E
19
-05
4,09E-05

4,09E-05

1,03E-03 1,48

1,08

4,62E+ 7,67E
19
-05
3,83E-05

3,83E-05

9,64E-04 1,39

1,08

4,87E+ 8,08E
19
-05
4,04E-05

4,04E-05

1,02E-03 1,46

1,08
23

7,3
1
7,7
0
7,8
9
7,8
0
7,4
0
7,7
0
7,9
9
7,8
0
7,8
0
7,3
1
7,7
0
7,8
9
8,0
9
8,2

7,3
1E
+0
0
7,7
0E
+0
0
7,8
9E
+0
0
7,8
0E
+0
0
7,4
0E
+0
0
7,7
0E
+0
0
7,9
9E
+0
0
7,8
0E
+0
0
7,8
0E
+0
0
7,3
1E
+0
0
7,7
0E
+0
0
7,8
9E
+0
0
8,0
9E
+0
0
8,2

4,56E+ 7,57E
19
-05
3,79E-05

3,79E-05

9,52E-04 1,37

1,07

4,81E+ 7,98E
19
-05
3,99E-05

3,99E-05

1,00E-03 1,44

1,08

4,93E+ 8,18E
19
-05
4,09E-05

4,09E-05

1,03E-03 1,48

1,07

4,87E+ 8,08E
19
-05
4,04E-05

4,04E-05

1,02E-03 1,46

1,09

4,62E+ 7,67E
19
-05
3,83E-05

3,83E-05

9,64E-04 1,39

1,07

4,81E+ 7,98E
19
-05
3,99E-05

3,99E-05

1,00E-03 1,44

1,05

4,99E+ 8,28E
19
-05
4,14E-05

4,14E-05

1,04E-03 1,50

1,06

4,87E+ 8,08E
19
-05
4,04E-05

4,04E-05

1,02E-03 1,46

1,07

4,87E+ 8,08E
19
-05
4,04E-05

4,04E-05

1,02E-03 1,46

1,08

4,56E+ 7,57E
19
-05
3,79E-05

3,79E-05

9,52E-04 1,37

1,07

4,81E+ 7,98E
19
-05
3,99E-05

3,99E-05

1,00E-03 1,44

1,07

4,93E+ 8,18E
19
-05
4,09E-05

4,09E-05

1,03E-03 1,48

1,08

5,05E+ 8,38E
19
-05
4,19E-05
5,17E+ 8,58E 4,29E-05

4,19E-05
4,29E-05

1,05E-03 1,52
1,08E-03 1,55

1,08
1,09
24

8
7,9
9
8,1
9
7,8
9
7,6
0
7,5
0
7,8
9
7,3
1
7,8
0
7,4
0
7,7
0
7,8
0
7,4
0
7,6
0

8E
+0
0
7,9
9E
+0
0
8,1
9E
+0
0
7,8
9E
+0
0
7,6
0E
+0
0
7,5
0E
+0
0
7,8
9E
+0
0
7,3
1E
+0
0
7,8
0E
+0
0
7,4
0E
+0
0
7,7
0E
+0
0
7,8
0E
+0
0
7,4
0E
+0
0
7,6
0E

19

-05

4,99E+ 8,28E
19
-05
4,14E-05

4,14E-05

1,04E-03 1,50

1,09

5,11E+ 8,49E
19
-05
4,24E-05

4,24E-05

1,07E-03 1,54

1,10

4,93E+ 8,18E
19
-05
4,09E-05

4,09E-05

1,03E-03 1,48

1,10

4,74E+ 7,88E
19
-05
3,94E-05

3,94E-05

9,90E-04 1,43

1,10

4,68E+ 7,77E
19
-05
3,89E-05

3,89E-05

9,77E-04 1,41

1,10

4,93E+ 8,18E
19
-05
4,09E-05

4,09E-05

1,03E-03 1,48

1,10

4,56E+ 7,57E
19
-05
3,79E-05

3,79E-05

9,52E-04 1,37

1,09

4,87E+ 8,08E
19
-05
4,04E-05

4,04E-05

1,02E-03 1,46

1,09

4,62E+ 7,67E
19
-05
3,83E-05

3,83E-05

9,64E-04 1,39

1,09

4,81E+ 7,98E
19
-05
3,99E-05

3,99E-05

1,00E-03 1,44

1,10

4,87E+ 8,08E
19
-05
4,04E-05

4,04E-05

1,02E-03 1,46

1,09

3,83E-05
3,94E-05

9,64E-04 1,39
9,90E-04 1,43

1,09
1,07

4,62E+
19
4,74E+
19

7,67E
-05
3,83E-05
7,88E 3,94E-05
-05

25

7,8
9
7,6
0
7,8
9
7,4
0
7,5
0
7,8
9
7,8
9
7,7
0
7,6
0
7,8
9
7,7
0
7,3
1
7,8
0

+0
0
7,8
9E
+0
0
7,6
0E
+0
0
7,8
9E
+0
0
7,4
0E
+0
0
7,5
0E
+0
0
7,8
9E
+0
0
7,8
9E
+0
0
7,7
0E
+0
0
7,6
0E
+0
0
7,8
9E
+0
0
7,7
0E
+0
0
7,3
1E
+0
0
7,8
0E
+0

4,93E+ 8,18E
19
-05
4,09E-05

4,09E-05

1,03E-03 1,48

1,08

4,74E+ 7,88E
19
-05
3,94E-05

3,94E-05

9,90E-04 1,43

1,07

4,93E+ 8,18E
19
-05
4,09E-05

4,09E-05

1,03E-03 1,48

1,07

4,62E+ 7,67E
19
-05
3,83E-05

3,83E-05

9,64E-04 1,39

1,09

4,68E+ 7,77E
19
-05
3,89E-05

3,89E-05

9,77E-04 1,41

1,09

4,93E+ 8,18E
19
-05
4,09E-05

4,09E-05

1,03E-03 1,48

1,09

4,93E+ 8,18E
19
-05
4,09E-05

4,09E-05

1,03E-03 1,48

1,09

4,81E+ 7,98E
19
-05
3,99E-05

3,99E-05

1,00E-03 1,44

1,07

4,74E+ 7,88E
19
-05
3,94E-05

3,94E-05

9,90E-04 1,43

1,07

4,93E+ 8,18E
19
-05
4,09E-05

4,09E-05

1,03E-03 1,48

1,09

4,81E+ 7,98E
19
-05
3,99E-05

3,99E-05

1,00E-03 1,44

1,08

3,79E-05
4,04E-05

9,52E-04 1,37
1,02E-03 1,46

1,09
1,07

4,56E+
19
4,87E+
19

7,57E
-05
3,79E-05
8,08E 4,04E-05
-05

26

7,8
9
7,8
9
7,6
0
7,9
9
7,6
0
7,8
9
7,3
1
7,6
0
7,8
9
7,7
0
8,0
9
7,4
0
7,6
0

0
7,8
9E
+0
0
7,8
9E
+0
0
7,6
0E
+0
0
7,9
9E
+0
0
7,6
0E
+0
0
7,8
9E
+0
0
7,3
1E
+0
0
7,6
0E
+0
0
7,8
9E
+0
0
7,7
0E
+0
0
8,0
9E
+0
0
7,4
0E
+0
0
7,6
0E
+0
0

4,93E+ 8,18E
19
-05
4,09E-05

4,09E-05

1,03E-03 1,48

1,09

4,93E+ 8,18E
19
-05
4,09E-05

4,09E-05

1,03E-03 1,48

1,06

4,74E+ 7,88E
19
-05
3,94E-05

3,94E-05

9,90E-04 1,43

1,07

4,99E+ 8,28E
19
-05
4,14E-05

4,14E-05

1,04E-03 1,50

1,07

4,74E+ 7,88E
19
-05
3,94E-05

3,94E-05

9,90E-04 1,43

1,06

4,93E+ 8,18E
19
-05
4,09E-05

4,09E-05

1,03E-03 1,48

1,07

4,56E+ 7,57E
19
-05
3,79E-05

3,79E-05

9,52E-04 1,37

1,08

4,74E+ 7,88E
19
-05
3,94E-05

3,94E-05

9,90E-04 1,43

1,07

4,93E+ 8,18E
19
-05
4,09E-05

4,09E-05

1,03E-03 1,48

1,09

4,81E+ 7,98E
19
-05
3,99E-05

3,99E-05

1,00E-03 1,44

1,07

5,05E+ 8,38E
19
-05
4,19E-05

4,19E-05

1,05E-03 1,52

1,07

4,62E+ 7,67E
19
-05
3,83E-05

3,83E-05

9,64E-04 1,39

1,08

4,74E+ 7,88E
19
-05
3,94E-05

3,94E-05

9,90E-04 1,43

1,06
27

7,4
0
7,8
0

7,4
0E
+0
0
7,8
0E
+0
0

4,62E+ 7,67E
19
-05
3,83E-05

3,83E-05

9,64E-04 1,39

1,07

4,87E+ 8,08E
19
-05
4,04E-05

4,04E-05

1,02E-03 1,46

1,07

Raw data for 10A

Numbe
Cur Cha r of
rent rge electro
(A) ( c) ns
1,3
1E
13, +0 8,16E+
07 1
19
1,3
6E
13, +0 8,46E+
56 1
19
1,3
5E
13, +0 8,40E+
46 1
19
1,3
1E
13, +0 8,16E+
07 1
19
1,3
3E
13, +0 8,28E+
26 1
19
1,3
5E
13, +0 8,40E+
46 1
19
1,3
4E
13, +0 8,34E+
36 1
19
1,3
5E
13, +0 8,40E+
46 1
19
13, 1,3 8,16E+
07 1E 19
+0

Number
Volumetr
Numb of
Hydrogen ic
er of hydrogen flowrate
flowrate
mols mols
(mol/s)
(l/s)

Volumetri
c flow
rate
(l/min)

Hydr
ogen
cons
ump
tion
[l/mi
n]

1,35E
-04
6,77E-05

6,77E-05

1,70E-03 2,45E+00 2,00

1,41E
-04
7,03E-05

7,03E-05

1,77E-03 2,54E+00 2,00

1,39E
-04
6,97E-05

6,97E-05

1,75E-03 2,53E+00 1,99

1,35E
-04
6,77E-05

6,77E-05

1,70E-03 2,45E+00 2,00

1,37E
-04
6,87E-05

6,87E-05

1,73E-03 2,49E+00 2,00

1,39E
-04
6,97E-05

6,97E-05

1,75E-03 2,53E+00 2,00

1,38E
-04
6,92E-05

6,92E-05

1,74E-03 2,51E+00 1,98

6,97E-05
6,77E-05

1,75E-03 2,53E+00 2,00


1,70E-03 2,45E+00 2,00

1,39E
-04
6,97E-05
1,35E 6,77E-05
-04

28

13,
36
13,
26
13,
36
13,
07
13,
36
13,
46
12,
97
13,
46
13,
56
13,
36
13,
36
13,
36
13,
07

1
1,3
4E
+0
1
1,3
3E
+0
1
1,3
4E
+0
1
1,3
1E
+0
1
1,3
4E
+0
1
1,3
5E
+0
1
1,3
0E
+0
1
1,3
5E
+0
1
1,3
6E
+0
1
1,3
4E
+0
1
1,3
4E
+0
1
1,3
4E
+0
1
1,3
1E
+0
1

8,34E+ 1,38E
19
-04
6,92E-05

6,92E-05

1,74E-03 2,51E+00 2,00

8,28E+ 1,37E
19
-04
6,87E-05

6,87E-05

1,73E-03 2,49E+00 1,98

8,34E+ 1,38E
19
-04
6,92E-05

6,92E-05

1,74E-03 2,51E+00 2,00

8,16E+ 1,35E
19
-04
6,77E-05

6,77E-05

1,70E-03 2,45E+00 2,00

8,34E+ 1,38E
19
-04
6,92E-05

6,92E-05

1,74E-03 2,51E+00 2,00

8,40E+ 1,39E
19
-04
6,97E-05

6,97E-05

1,75E-03 2,53E+00 1,99

8,10E+ 1,34E
19
-04
6,72E-05

6,72E-05

1,69E-03 2,43E+00 2,00

8,40E+ 1,39E
19
-04
6,97E-05

6,97E-05

1,75E-03 2,53E+00 2,00

8,46E+ 1,41E
19
-04
7,03E-05

7,03E-05

1,77E-03 2,54E+00 1,98

8,34E+ 1,38E
19
-04
6,92E-05

6,92E-05

1,74E-03 2,51E+00 1,98

8,34E+ 1,38E
19
-04
6,92E-05

6,92E-05

1,74E-03 2,51E+00 2,00

8,34E+ 1,38E
19
-04
6,92E-05

6,92E-05

1,74E-03 2,51E+00 2,00

8,16E+ 1,35E
19
-04
6,77E-05

6,77E-05

1,70E-03 2,45E+00 2,00


29

13,
07
13,
36
13,
36
13,
17
13,
07
13,
46
13,
36
13,
56
13,
26
13,
17
13,
07
13,
26
13,
56
13,

1,3
1E
+0
1
1,3
4E
+0
1
1,3
4E
+0
1
1,3
2E
+0
1
1,3
1E
+0
1
1,3
5E
+0
1
1,3
4E
+0
1
1,3
6E
+0
1
1,3
3E
+0
1
1,3
2E
+0
1
1,3
1E
+0
1
1,3
3E
+0
1
1,3
6E
+0
1
1,3

8,16E+ 1,35E
19
-04
6,77E-05

6,77E-05

1,70E-03 2,45E+00 2,00

8,34E+ 1,38E
19
-04
6,92E-05

6,92E-05

1,74E-03 2,51E+00 2,00

8,34E+ 1,38E
19
-04
6,92E-05

6,92E-05

1,74E-03 2,51E+00 2,01

8,22E+ 1,36E
19
-04
6,82E-05

6,82E-05

1,72E-03 2,47E+00 2,00

8,16E+ 1,35E
19
-04
6,77E-05

6,77E-05

1,70E-03 2,45E+00 1,99

8,40E+ 1,39E
19
-04
6,97E-05

6,97E-05

1,75E-03 2,53E+00 1,99

8,34E+ 1,38E
19
-04
6,92E-05

6,92E-05

1,74E-03 2,51E+00 2,00

8,46E+ 1,41E
19
-04
7,03E-05

7,03E-05

1,77E-03 2,54E+00 2,01

8,28E+ 1,37E
19
-04
6,87E-05

6,87E-05

1,73E-03 2,49E+00 1,98

8,22E+ 1,36E
19
-04
6,82E-05

6,82E-05

1,72E-03 2,47E+00 2,00

8,16E+ 1,35E
19
-04
6,77E-05

6,77E-05

1,70E-03 2,45E+00 2,00

8,28E+ 1,37E
19
-04
6,87E-05

6,87E-05

1,73E-03 2,49E+00 2,00

8,46E+ 1,41E
19
-04
7,03E-05
8,40E+ 1,39E 6,97E-05

7,03E-05
6,97E-05

1,77E-03 2,54E+00 2,01


1,75E-03 2,53E+00 2,00
30

46
13,
56
13,
46
13,
36
13,
46
13,
36
13,
17
13,
36
13,
46
13,
07
13,
07
13,
56
13,
26
13,
17

5E
+0
1
1,3
6E
+0
1
1,3
5E
+0
1
1,3
4E
+0
1
1,3
5E
+0
1
1,3
4E
+0
1
1,3
2E
+0
1
1,3
4E
+0
1
1,3
5E
+0
1
1,3
1E
+0
1
1,3
1E
+0
1
1,3
6E
+0
1
1,3
3E
+0
1
1,3
2E

19

-04

8,46E+ 1,41E
19
-04
7,03E-05

7,03E-05

1,77E-03 2,54E+00 2,00

8,40E+ 1,39E
19
-04
6,97E-05

6,97E-05

1,75E-03 2,53E+00 2,00

8,34E+ 1,38E
19
-04
6,92E-05

6,92E-05

1,74E-03 2,51E+00 2,00

8,40E+ 1,39E
19
-04
6,97E-05

6,97E-05

1,75E-03 2,53E+00 2,00

8,34E+ 1,38E
19
-04
6,92E-05

6,92E-05

1,74E-03 2,51E+00 1,99

8,22E+ 1,36E
19
-04
6,82E-05

6,82E-05

1,72E-03 2,47E+00 2,00

8,34E+ 1,38E
19
-04
6,92E-05

6,92E-05

1,74E-03 2,51E+00 2,00

8,40E+ 1,39E
19
-04
6,97E-05

6,97E-05

1,75E-03 2,53E+00 2,00

8,16E+ 1,35E
19
-04
6,77E-05

6,77E-05

1,70E-03 2,45E+00 2,00

8,16E+ 1,35E
19
-04
6,77E-05

6,77E-05

1,70E-03 2,45E+00 2,00

8,46E+ 1,41E
19
-04
7,03E-05

7,03E-05

1,77E-03 2,54E+00 2,02

6,87E-05
6,82E-05

1,73E-03 2,49E+00 2,00


1,72E-03 2,47E+00 2,00

8,28E+
19
8,22E+
19

1,37E
-04
6,87E-05
1,36E 6,82E-05
-04

31

13,
46
13,
46
13,
07
13,
26
13,
17
13,
36
13,
36
13,
56
13,
26
13,
46
13,
36
13,
46
13,
56

+0
1
1,3
5E
+0
1
1,3
5E
+0
1
1,3
1E
+0
1
1,3
3E
+0
1
1,3
2E
+0
1
1,3
4E
+0
1
1,3
4E
+0
1
1,3
6E
+0
1
1,3
3E
+0
1
1,3
5E
+0
1
1,3
4E
+0
1
1,3
5E
+0
1
1,3
6E
+0

8,40E+ 1,39E
19
-04
6,97E-05

6,97E-05

1,75E-03 2,53E+00 2,00

8,40E+ 1,39E
19
-04
6,97E-05

6,97E-05

1,75E-03 2,53E+00 2,00

8,16E+ 1,35E
19
-04
6,77E-05

6,77E-05

1,70E-03 2,45E+00 2,01

8,28E+ 1,37E
19
-04
6,87E-05

6,87E-05

1,73E-03 2,49E+00 2,01

8,22E+ 1,36E
19
-04
6,82E-05

6,82E-05

1,72E-03 2,47E+00 2,00

8,34E+ 1,38E
19
-04
6,92E-05

6,92E-05

1,74E-03 2,51E+00 2,01

8,34E+ 1,38E
19
-04
6,92E-05

6,92E-05

1,74E-03 2,51E+00 2,01

8,46E+ 1,41E
19
-04
7,03E-05

7,03E-05

1,77E-03 2,54E+00 2,00

8,28E+ 1,37E
19
-04
6,87E-05

6,87E-05

1,73E-03 2,49E+00 2,00

8,40E+ 1,39E
19
-04
6,97E-05

6,97E-05

1,75E-03 2,53E+00 2,00

8,34E+ 1,38E
19
-04
6,92E-05

6,92E-05

1,74E-03 2,51E+00 2,00

6,97E-05
7,03E-05

1,75E-03 2,53E+00 2,00


1,77E-03 2,54E+00 2,00

8,40E+
19
8,46E+
19

1,39E
-04
6,97E-05
1,41E 7,03E-05
-04

32

13,
56
13,
56
13,
46
13,
46
13,
26
13,
26
13,
46
13,
36
13,
07
13,
36
12,
97
13,
46
13,
36

1
1,3
6E
+0
1
1,3
6E
+0
1
1,3
5E
+0
1
1,3
5E
+0
1
1,3
3E
+0
1
1,3
3E
+0
1
1,3
5E
+0
1
1,3
4E
+0
1
1,3
1E
+0
1
1,3
4E
+0
1
1,3
0E
+0
1
1,3
5E
+0
1
1,3
4E
+0
1

8,46E+ 1,41E
19
-04
7,03E-05

7,03E-05

1,77E-03 2,54E+00 2,00

8,46E+ 1,41E
19
-04
7,03E-05

7,03E-05

1,77E-03 2,54E+00 2,00

8,40E+ 1,39E
19
-04
6,97E-05

6,97E-05

1,75E-03 2,53E+00 2,01

8,40E+ 1,39E
19
-04
6,97E-05

6,97E-05

1,75E-03 2,53E+00 2,01

8,28E+ 1,37E
19
-04
6,87E-05

6,87E-05

1,73E-03 2,49E+00 2,01

8,28E+ 1,37E
19
-04
6,87E-05

6,87E-05

1,73E-03 2,49E+00 2,00

8,40E+ 1,39E
19
-04
6,97E-05

6,97E-05

1,75E-03 2,53E+00 2,00

8,34E+ 1,38E
19
-04
6,92E-05

6,92E-05

1,74E-03 2,51E+00 2,00

8,16E+ 1,35E
19
-04
6,77E-05

6,77E-05

1,70E-03 2,45E+00 2,01

8,34E+ 1,38E
19
-04
6,92E-05

6,92E-05

1,74E-03 2,51E+00 2,00

8,10E+ 1,34E
19
-04
6,72E-05

6,72E-05

1,69E-03 2,43E+00 2,00

8,40E+ 1,39E
19
-04
6,97E-05

6,97E-05

1,75E-03 2,53E+00 2,00

8,34E+ 1,38E
19
-04
6,92E-05

6,92E-05

1,74E-03 2,51E+00 2,00


33

13,
07
13,
36
13,
46
13,
46
13,
36
13,
17
13,
17
13,
46
13,
26
12,
97
13,
46
13,
26
13,
46
13,

1,3
1E
+0
1
1,3
4E
+0
1
1,3
5E
+0
1
1,3
5E
+0
1
1,3
4E
+0
1
1,3
2E
+0
1
1,3
2E
+0
1
1,3
5E
+0
1
1,3
3E
+0
1
1,3
0E
+0
1
1,3
5E
+0
1
1,3
3E
+0
1
1,3
5E
+0
1
1,3

8,16E+ 1,35E
19
-04
6,77E-05

6,77E-05

1,70E-03 2,45E+00 2,00

8,34E+ 1,38E
19
-04
6,92E-05

6,92E-05

1,74E-03 2,51E+00 1,99

8,40E+ 1,39E
19
-04
6,97E-05

6,97E-05

1,75E-03 2,53E+00 2,00

8,40E+ 1,39E
19
-04
6,97E-05

6,97E-05

1,75E-03 2,53E+00 2,00

8,34E+ 1,38E
19
-04
6,92E-05

6,92E-05

1,74E-03 2,51E+00 2,00

8,22E+ 1,36E
19
-04
6,82E-05

6,82E-05

1,72E-03 2,47E+00 2,01

8,22E+ 1,36E
19
-04
6,82E-05

6,82E-05

1,72E-03 2,47E+00 2,01

8,40E+ 1,39E
19
-04
6,97E-05

6,97E-05

1,75E-03 2,53E+00 2,00

8,28E+ 1,37E
19
-04
6,87E-05

6,87E-05

1,73E-03 2,49E+00 2,01

8,10E+ 1,34E
19
-04
6,72E-05

6,72E-05

1,69E-03 2,43E+00 2,00

8,40E+ 1,39E
19
-04
6,97E-05

6,97E-05

1,75E-03 2,53E+00 2,00

8,28E+ 1,37E
19
-04
6,87E-05

6,87E-05

1,73E-03 2,49E+00 2,00

8,40E+ 1,39E
19
-04
6,97E-05
8,40E+ 1,39E 6,97E-05

6,97E-05
6,97E-05

1,75E-03 2,53E+00 2,02


1,75E-03 2,53E+00 2,00
34

46
12,
97
13,
46
13,
46
13,
07
13,
36
13,
36
13,
46
13,
46
13,
17
13,
26

5E
+0
1
1,3
0E
+0
1
1,3
5E
+0
1
1,3
5E
+0
1
1,3
1E
+0
1
1,3
4E
+0
1
1,3
4E
+0
1
1,3
5E
+0
1
1,3
5E
+0
1
1,3
2E
+0
1
1,3
3E
+0
1

19

-04

8,10E+ 1,34E
19
-04
6,72E-05

6,72E-05

1,69E-03 2,43E+00 2,00

8,40E+ 1,39E
19
-04
6,97E-05

6,97E-05

1,75E-03 2,53E+00 2,01

8,40E+ 1,39E
19
-04
6,97E-05

6,97E-05

1,75E-03 2,53E+00 2,01

8,16E+ 1,35E
19
-04
6,77E-05

6,77E-05

1,70E-03 2,45E+00 2,01

8,34E+ 1,38E
19
-04
6,92E-05

6,92E-05

1,74E-03 2,51E+00 2,00

8,34E+ 1,38E
19
-04
6,92E-05

6,92E-05

1,74E-03 2,51E+00 2,00

8,40E+ 1,39E
19
-04
6,97E-05

6,97E-05

1,75E-03 2,53E+00 2,01

8,40E+ 1,39E
19
-04
6,97E-05

6,97E-05

1,75E-03 2,53E+00 2,01

8,22E+ 1,36E
19
-04
6,82E-05

6,82E-05

1,72E-03 2,47E+00 2,01

8,28E+ 1,37E
19
-04
6,87E-05

6,87E-05

1,73E-03 2,49E+00 2,01

Raw data for 15A


Hydr
ogen
cons
Numbe
Number
Volumetr Volumetri ump
Cur Cha r of
Numb of
Hydrogen ic
c flow
tion
rent rge electro er of hydrogen flowrate
flowrate rate
[l/mi
(A) ( c) ns
mols mols
(mol/s)
(l/s)
(l/min)
n]
18, 1,8 1,17E+ 1,94E 9,70E-05 9,70E-05 2,44E-03 3,51E+00 2,89
35

73
18,
73
18,
93
18,
73
18,
64
18,
93
18,
73
18,
83
18,
83
18,
93
18,
83
18,
83
18,
73
18,
83

7E
+0
1
1,8
7E
+0
1
1,8
9E
+0
1
1,8
7E
+0
1
1,8
6E
+0
1
1,8
9E
+0
1
1,8
7E
+0
1
1,8
8E
+0
1
1,8
8E
+0
1
1,8
9E
+0
1
1,8
8E
+0
1
1,8
8E
+0
1
1,8
7E
+0
1
1,8
8E

20

-04

1,17E+ 1,94E
20
-04
9,70E-05

9,70E-05

2,44E-03 3,51E+00 2,90

1,18E+ 1,96E
20
-04
9,81E-05

9,81E-05

2,47E-03 3,55E+00 2,89

1,17E+ 1,94E
20
-04
9,70E-05

9,70E-05

2,44E-03 3,51E+00 2,89

1,16E+ 1,93E
20
-04
9,66E-05

9,66E-05

2,43E-03 3,50E+00 2,89

1,18E+ 1,96E
20
-04
9,81E-05

9,81E-05

2,47E-03 3,55E+00 2,90

1,17E+ 1,94E
20
-04
9,70E-05

9,70E-05

2,44E-03 3,51E+00 2,90

1,18E+ 1,95E
20
-04
9,76E-05

9,76E-05

2,45E-03 3,53E+00 2,90

1,18E+ 1,95E
20
-04
9,76E-05

9,76E-05

2,45E-03 3,53E+00 2,91

1,18E+ 1,96E
20
-04
9,81E-05

9,81E-05

2,47E-03 3,55E+00 2,89

1,18E+ 1,95E
20
-04
9,76E-05

9,76E-05

2,45E-03 3,53E+00 2,90

1,18E+ 1,95E
20
-04
9,76E-05

9,76E-05

2,45E-03 3,53E+00 2,89

9,70E-05
9,76E-05

2,44E-03 3,51E+00 2,90


2,45E-03 3,53E+00 2,90

1,17E+
20
1,18E+
20

1,94E
-04
9,70E-05
1,95E 9,76E-05
-04

36

18,
83
18,
73
18,
73
18,
64
18,
93
18,
93
18,
73
18,
73
18,
83
18,
83
18,
73
18,
83
18,
93

+0
1
1,8
8E
+0
1
1,8
7E
+0
1
1,8
7E
+0
1
1,8
6E
+0
1
1,8
9E
+0
1
1,8
9E
+0
1
1,8
7E
+0
1
1,8
7E
+0
1
1,8
8E
+0
1
1,8
8E
+0
1
1,8
7E
+0
1
1,8
8E
+0
1
1,8
9E
+0

1,18E+ 1,95E
20
-04
9,76E-05

9,76E-05

2,45E-03 3,53E+00 2,90

1,17E+ 1,94E
20
-04
9,70E-05

9,70E-05

2,44E-03 3,51E+00 2,90

1,17E+ 1,94E
20
-04
9,70E-05

9,70E-05

2,44E-03 3,51E+00 2,89

1,16E+ 1,93E
20
-04
9,66E-05

9,66E-05

2,43E-03 3,50E+00 2,91

1,18E+ 1,96E
20
-04
9,81E-05

9,81E-05

2,47E-03 3,55E+00 2,90

1,18E+ 1,96E
20
-04
9,81E-05

9,81E-05

2,47E-03 3,55E+00 2,90

1,17E+ 1,94E
20
-04
9,70E-05

9,70E-05

2,44E-03 3,51E+00 2,89

1,17E+ 1,94E
20
-04
9,70E-05

9,70E-05

2,44E-03 3,51E+00 2,90

1,18E+ 1,95E
20
-04
9,76E-05

9,76E-05

2,45E-03 3,53E+00 2,92

1,18E+ 1,95E
20
-04
9,76E-05

9,76E-05

2,45E-03 3,53E+00 2,90

1,17E+ 1,94E
20
-04
9,70E-05

9,70E-05

2,44E-03 3,51E+00 2,90

9,76E-05
9,81E-05

2,45E-03 3,53E+00 2,89


2,47E-03 3,55E+00 2,89

1,18E+
20
1,18E+
20

1,95E
-04
9,76E-05
1,96E 9,81E-05
-04

37

18,
83
18,
83
18,
64
18,
83
18,
83
18,
83
18,
83
18,
73
18,
73
18,
83
18,
83
18,
73
18,
83

1
1,8
8E
+0
1
1,8
8E
+0
1
1,8
6E
+0
1
1,8
8E
+0
1
1,8
8E
+0
1
1,8
8E
+0
1
1,8
8E
+0
1
1,8
7E
+0
1
1,8
7E
+0
1
1,8
8E
+0
1
1,8
8E
+0
1
1,8
7E
+0
1
1,8
8E
+0
1

1,18E+ 1,95E
20
-04
9,76E-05

9,76E-05

2,45E-03 3,53E+00 2,88

1,18E+ 1,95E
20
-04
9,76E-05

9,76E-05

2,45E-03 3,53E+00 2,88

1,16E+ 1,93E
20
-04
9,66E-05

9,66E-05

2,43E-03 3,50E+00 2,90

1,18E+ 1,95E
20
-04
9,76E-05

9,76E-05

2,45E-03 3,53E+00 2,90

1,18E+ 1,95E
20
-04
9,76E-05

9,76E-05

2,45E-03 3,53E+00 2,90

1,18E+ 1,95E
20
-04
9,76E-05

9,76E-05

2,45E-03 3,53E+00 2,89

1,18E+ 1,95E
20
-04
9,76E-05

9,76E-05

2,45E-03 3,53E+00 2,90

1,17E+ 1,94E
20
-04
9,70E-05

9,70E-05

2,44E-03 3,51E+00 2,90

1,17E+ 1,94E
20
-04
9,70E-05

9,70E-05

2,44E-03 3,51E+00 2,90

1,18E+ 1,95E
20
-04
9,76E-05

9,76E-05

2,45E-03 3,53E+00 2,89

1,18E+ 1,95E
20
-04
9,76E-05

9,76E-05

2,45E-03 3,53E+00 2,89

1,17E+ 1,94E
20
-04
9,70E-05

9,70E-05

2,44E-03 3,51E+00 2,89

1,18E+ 1,95E
20
-04
9,76E-05

9,76E-05

2,45E-03 3,53E+00 2,90


38

18,
64
18,
83
18,
83
18,
93
18,
83
18,
73
18,
83
18,
73
18,
73
18,
83
18,
83
18,
73
18,
73
18,

1,8
6E
+0
1
1,8
8E
+0
1
1,8
8E
+0
1
1,8
9E
+0
1
1,8
8E
+0
1
1,8
7E
+0
1
1,8
8E
+0
1
1,8
7E
+0
1
1,8
7E
+0
1
1,8
8E
+0
1
1,8
8E
+0
1
1,8
7E
+0
1
1,8
7E
+0
1
1,8

1,16E+ 1,93E
20
-04
9,66E-05

9,66E-05

2,43E-03 3,50E+00 2,90

1,18E+ 1,95E
20
-04
9,76E-05

9,76E-05

2,45E-03 3,53E+00 2,90

1,18E+ 1,95E
20
-04
9,76E-05

9,76E-05

2,45E-03 3,53E+00 2,91

1,18E+ 1,96E
20
-04
9,81E-05

9,81E-05

2,47E-03 3,55E+00 2,90

1,18E+ 1,95E
20
-04
9,76E-05

9,76E-05

2,45E-03 3,53E+00 2,89

1,17E+ 1,94E
20
-04
9,70E-05

9,70E-05

2,44E-03 3,51E+00 2,89

1,18E+ 1,95E
20
-04
9,76E-05

9,76E-05

2,45E-03 3,53E+00 2,91

1,17E+ 1,94E
20
-04
9,70E-05

9,70E-05

2,44E-03 3,51E+00 2,89

1,17E+ 1,94E
20
-04
9,70E-05

9,70E-05

2,44E-03 3,51E+00 2,92

1,18E+ 1,95E
20
-04
9,76E-05

9,76E-05

2,45E-03 3,53E+00 2,90

1,18E+ 1,95E
20
-04
9,76E-05

9,76E-05

2,45E-03 3,53E+00 2,91

1,17E+ 1,94E
20
-04
9,70E-05

9,70E-05

2,44E-03 3,51E+00 2,92

1,17E+ 1,94E
20
-04
9,70E-05
1,18E+ 1,95E 9,76E-05

9,70E-05
9,76E-05

2,44E-03 3,51E+00 2,90


2,45E-03 3,53E+00 2,90
39

83
18,
73
18,
83
18,
83
18,
73
18,
83
18,
83
18,
73
18,
83
18,
83
18,
73
18,
73
18,
83
18,
93

8E
+0
1
1,8
7E
+0
1
1,8
8E
+0
1
1,8
8E
+0
1
1,8
7E
+0
1
1,8
8E
+0
1
1,8
8E
+0
1
1,8
7E
+0
1
1,8
8E
+0
1
1,8
8E
+0
1
1,8
7E
+0
1
1,8
7E
+0
1
1,8
8E
+0
1
1,8
9E

20

-04

1,17E+ 1,94E
20
-04
9,70E-05

9,70E-05

2,44E-03 3,51E+00 2,90

1,18E+ 1,95E
20
-04
9,76E-05

9,76E-05

2,45E-03 3,53E+00 2,92

1,18E+ 1,95E
20
-04
9,76E-05

9,76E-05

2,45E-03 3,53E+00 2,90

1,17E+ 1,94E
20
-04
9,70E-05

9,70E-05

2,44E-03 3,51E+00 2,89

1,18E+ 1,95E
20
-04
9,76E-05

9,76E-05

2,45E-03 3,53E+00 2,92

1,18E+ 1,95E
20
-04
9,76E-05

9,76E-05

2,45E-03 3,53E+00 2,89

1,17E+ 1,94E
20
-04
9,70E-05

9,70E-05

2,44E-03 3,51E+00 2,91

1,18E+ 1,95E
20
-04
9,76E-05

9,76E-05

2,45E-03 3,53E+00 2,90

1,18E+ 1,95E
20
-04
9,76E-05

9,76E-05

2,45E-03 3,53E+00 2,90

1,17E+ 1,94E
20
-04
9,70E-05

9,70E-05

2,44E-03 3,51E+00 2,89

1,17E+ 1,94E
20
-04
9,70E-05

9,70E-05

2,44E-03 3,51E+00 2,91

9,76E-05
9,81E-05

2,45E-03 3,53E+00 2,92


2,47E-03 3,55E+00 2,91

1,18E+
20
1,18E+
20

1,95E
-04
9,76E-05
1,96E 9,81E-05
-04

40

18,
83
18,
83
18,
83
18,
83

+0
1
1,8
8E
+0
1
1,8
8E
+0
1
1,8
8E
+0
1
1,8
8E
+0
1

1,18E+ 1,95E
20
-04
9,76E-05

9,76E-05

2,45E-03 3,53E+00 2,91

1,18E+ 1,95E
20
-04
9,76E-05

9,76E-05

2,45E-03 3,53E+00 2,91

1,18E+ 1,95E
20
-04
9,76E-05

9,76E-05

2,45E-03 3,53E+00 2,90

1,18E+ 1,95E
20
-04
9,76E-05

9,76E-05

2,45E-03 3,53E+00 2,91

Raw data for 19A

Numbe
Cur Cha r of
rent rge electro
(A) ( c) ns
21, 21, 1,37E+
96 96 20
21, 21, 1,37E+
96 96 20
22, 22, 1,38E+
05 05 20
21, 21, 1,37E+
96 96 20
21, 21, 1,37E+
96 96 20
21, 21, 1,37E+
96 96 20
22, 22, 1,38E+
15 15 20
22, 22, 1,38E+
05 05 20
22, 22, 1,38E+
15 15 20
22, 22, 1,38E+
05 05 20
22, 22, 1,38E+
05 05 20
22, 22, 1,38E+
15 15 20
22, 22, 1,38E+

Number
Volumetr
Numb of
Hydrogen ic
er of hydrogen flowrate
flowrate
mols mols
(mol/s)
(l/s)
2,28E
-04
1,14E-04 1,14E-04 2,86E-03
2,28E
-04
1,14E-04 1,14E-04 2,86E-03
2,28E
-04
1,14E-04 1,14E-04 2,87E-03
2,28E
-04
1,14E-04 1,14E-04 2,86E-03
2,28E
-04
1,14E-04 1,14E-04 2,86E-03
2,28E
-04
1,14E-04 1,14E-04 2,86E-03
2,30E
-04
1,15E-04 1,15E-04 2,89E-03
2,28E
-04
1,14E-04 1,14E-04 2,87E-03
2,30E
-04
1,15E-04 1,15E-04 2,89E-03
2,28E
-04
1,14E-04 1,14E-04 2,87E-03
2,28E
-04
1,14E-04 1,14E-04 2,87E-03
2,30E
-04
1,15E-04 1,15E-04 2,89E-03
2,30E 1,15E-04 1,15E-04 2,89E-03

Volumetri
c flow
rate
(l/min)

Hydr
ogen
cons
ump
tion
[l/mi
n]

4,12E+00 3,43
4,12E+00 3,43
4,14E+00 3,43
4,12E+00 3,44
4,12E+00 3,44
4,12E+00 3,46
4,16E+00 3,45
4,14E+00 3,44
4,16E+00 3,46
4,14E+00 3,44
4,14E+00 3,46
4,16E+00 3,45
4,16E+00 3,46
41

15
22,
05
21,
96
22,
15
22,
05
22,
05
22,
15
22,
25
22,
05
22,
15
22,
15
22,
15
22,
15
22,
25
22,
15
22,
15
22,
15
22,
15
22,
15
22,
15
22,
25
22,
05
22,
25
22,
35
22,
15
22,
15
22,
25

15
22,
05
21,
96
22,
15
22,
05
22,
05
22,
15
22,
25
22,
05
22,
15
22,
15
22,
15
22,
15
22,
25
22,
15
22,
15
22,
15
22,
15
22,
15
22,
15
22,
25
22,
05
22,
25
22,
35
22,
15
22,
15
22,
25

20
1,38E+
20
1,37E+
20
1,38E+
20
1,38E+
20
1,38E+
20
1,38E+
20
1,39E+
20
1,38E+
20
1,38E+
20
1,38E+
20
1,38E+
20
1,38E+
20
1,39E+
20
1,38E+
20
1,38E+
20
1,38E+
20
1,38E+
20
1,38E+
20
1,38E+
20
1,39E+
20
1,38E+
20
1,39E+
20
1,40E+
20
1,38E+
20
1,38E+
20
1,39E+
20

-04
2,28E
-04
2,28E
-04
2,30E
-04
2,28E
-04
2,28E
-04
2,30E
-04
2,31E
-04
2,28E
-04
2,30E
-04
2,30E
-04
2,30E
-04
2,30E
-04
2,31E
-04
2,30E
-04
2,30E
-04
2,30E
-04
2,30E
-04
2,30E
-04
2,30E
-04
2,31E
-04
2,28E
-04
2,31E
-04
2,32E
-04
2,30E
-04
2,30E
-04
2,31E
-04

1,14E-04

1,14E-04

2,87E-03 4,14E+00 3,45

1,14E-04

1,14E-04

2,86E-03 4,12E+00 3,45

1,15E-04

1,15E-04

2,89E-03 4,16E+00 3,47

1,14E-04

1,14E-04

2,87E-03 4,14E+00 3,45

1,14E-04

1,14E-04

2,87E-03 4,14E+00 3,45

1,15E-04

1,15E-04

2,89E-03 4,16E+00 3,45

1,15E-04

1,15E-04

2,90E-03 4,17E+00 3,45

1,14E-04

1,14E-04

2,87E-03 4,14E+00 3,46

1,15E-04

1,15E-04

2,89E-03 4,16E+00 3,44

1,15E-04

1,15E-04

2,89E-03 4,16E+00 3,45

1,15E-04

1,15E-04

2,89E-03 4,16E+00 3,47

1,15E-04

1,15E-04

2,89E-03 4,16E+00 3,47

1,15E-04

1,15E-04

2,90E-03 4,17E+00 3,47

1,15E-04

1,15E-04

2,89E-03 4,16E+00 3,47

1,15E-04

1,15E-04

2,89E-03 4,16E+00 3,47

1,15E-04

1,15E-04

2,89E-03 4,16E+00 3,47

1,15E-04

1,15E-04

2,89E-03 4,16E+00 3,47

1,15E-04

1,15E-04

2,89E-03 4,16E+00 3,47

1,15E-04

1,15E-04

2,89E-03 4,16E+00 3,47

1,15E-04

1,15E-04

2,90E-03 4,17E+00 3,46

1,14E-04

1,14E-04

2,87E-03 4,14E+00 3,47

1,15E-04

1,15E-04

2,90E-03 4,17E+00 3,47

1,16E-04

1,16E-04

2,91E-03 4,19E+00 3,45

1,15E-04

1,15E-04

2,89E-03 4,16E+00 3,47

1,15E-04

1,15E-04

2,89E-03 4,16E+00 3,47

1,15E-04

1,15E-04

2,90E-03 4,17E+00 3,46


42

22,
25
22,
15
22,
35
22,
25
22,
25
22,
25
22,
25
22,
25
22,
25
22,
35
22,
25
22,
25
22,
44
22,
44
22,
25
22,
25
22,
35
22,
35
22,
25
22,
35
22,
35
22,
25
22,
35
22,
35
22,
25
22,
25
22,

22,
25
22,
15
22,
35
22,
25
22,
25
22,
25
22,
25
22,
25
22,
25
22,
35
22,
25
22,
25
22,
44
22,
44
22,
25
22,
25
22,
35
22,
35
22,
25
22,
35
22,
35
22,
25
22,
35
22,
35
22,
25
22,
25
22,

1,39E+
20
1,38E+
20
1,40E+
20
1,39E+
20
1,39E+
20
1,39E+
20
1,39E+
20
1,39E+
20
1,39E+
20
1,40E+
20
1,39E+
20
1,39E+
20
1,40E+
20
1,40E+
20
1,39E+
20
1,39E+
20
1,40E+
20
1,40E+
20
1,39E+
20
1,40E+
20
1,40E+
20
1,39E+
20
1,40E+
20
1,40E+
20
1,39E+
20
1,39E+
20
1,40E+

2,31E
-04
2,30E
-04
2,32E
-04
2,31E
-04
2,31E
-04
2,31E
-04
2,31E
-04
2,31E
-04
2,31E
-04
2,32E
-04
2,31E
-04
2,31E
-04
2,33E
-04
2,33E
-04
2,31E
-04
2,31E
-04
2,32E
-04
2,32E
-04
2,31E
-04
2,32E
-04
2,32E
-04
2,31E
-04
2,32E
-04
2,32E
-04
2,31E
-04
2,31E
-04
2,32E

1,15E-04

1,15E-04

2,90E-03 4,17E+00 3,47

1,15E-04

1,15E-04

2,89E-03 4,16E+00 3,45

1,16E-04

1,16E-04

2,91E-03 4,19E+00 3,45

1,15E-04

1,15E-04

2,90E-03 4,17E+00 3,47

1,15E-04

1,15E-04

2,90E-03 4,17E+00 3,48

1,15E-04

1,15E-04

2,90E-03 4,17E+00 3,48

1,15E-04

1,15E-04

2,90E-03 4,17E+00 3,48

1,15E-04

1,15E-04

2,90E-03 4,17E+00 3,48

1,15E-04

1,15E-04

2,90E-03 4,17E+00 3,47

1,16E-04

1,16E-04

2,91E-03 4,19E+00 3,48

1,15E-04

1,15E-04

2,90E-03 4,17E+00 3,48

1,15E-04

1,15E-04

2,90E-03 4,17E+00 3,50

1,16E-04

1,16E-04

2,92E-03 4,21E+00 3,49

1,16E-04

1,16E-04

2,92E-03 4,21E+00 3,48

1,15E-04

1,15E-04

2,90E-03 4,17E+00 3,50

1,15E-04

1,15E-04

2,90E-03 4,17E+00 3,48

1,16E-04

1,16E-04

2,91E-03 4,19E+00 3,48

1,16E-04

1,16E-04

2,91E-03 4,19E+00 3,50

1,15E-04

1,15E-04

2,90E-03 4,17E+00 3,48

1,16E-04

1,16E-04

2,91E-03 4,19E+00 3,48

1,16E-04

1,16E-04

2,91E-03 4,19E+00 3,50

1,15E-04

1,15E-04

2,90E-03 4,17E+00 3,48

1,16E-04

1,16E-04

2,91E-03 4,19E+00 3,48

1,16E-04

1,16E-04

2,91E-03 4,19E+00 3,48

1,15E-04

1,15E-04

2,90E-03 4,17E+00 3,47

1,15E-04
1,16E-04

1,15E-04
1,16E-04

2,90E-03 4,17E+00 3,48


2,91E-03 4,19E+00 3,48
43

35
22,
35
22,
25
22,
35
22,
35
22,
35
22,
35
22,
25
22,
35
22,
25
22,
35
22,
35
22,
35
22,
25
22,
25
22,
25

35
22,
35
22,
25
22,
35
22,
35
22,
35
22,
35
22,
25
22,
35
22,
25
22,
35
22,
35
22,
35
22,
25
22,
25
22,
25

20
1,40E+
20
1,39E+
20
1,40E+
20
1,40E+
20
1,40E+
20
1,40E+
20
1,39E+
20
1,40E+
20
1,39E+
20
1,40E+
20
1,40E+
20
1,40E+
20
1,39E+
20
1,39E+
20
1,39E+
20

-04
2,32E
-04
2,31E
-04
2,32E
-04
2,32E
-04
2,32E
-04
2,32E
-04
2,31E
-04
2,32E
-04
2,31E
-04
2,32E
-04
2,32E
-04
2,32E
-04
2,31E
-04
2,31E
-04
2,31E
-04

1,16E-04

1,16E-04

2,91E-03 4,19E+00 3,48

1,15E-04

1,15E-04

2,90E-03 4,17E+00 3,48

1,16E-04

1,16E-04

2,91E-03 4,19E+00 3,48

1,16E-04

1,16E-04

2,91E-03 4,19E+00 3,48

1,16E-04

1,16E-04

2,91E-03 4,19E+00 3,47

1,16E-04

1,16E-04

2,91E-03 4,19E+00 3,49

1,15E-04

1,15E-04

2,90E-03 4,17E+00 3,48

1,16E-04

1,16E-04

2,91E-03 4,19E+00 3,49

1,15E-04

1,15E-04

2,90E-03 4,17E+00 3,48

1,16E-04

1,16E-04

2,91E-03 4,19E+00 3,48

1,16E-04

1,16E-04

2,91E-03 4,19E+00 3,48

1,16E-04

1,16E-04

2,91E-03 4,19E+00 3,48

1,15E-04

1,15E-04

2,90E-03 4,17E+00 3,48

1,15E-04

1,15E-04

2,90E-03 4,17E+00 3,49

1,15E-04

1,15E-04

2,90E-03 4,17E+00 3,48

13.2. Energy Balance Raw data


Raw data for 5A

Tim
e(s)
1
2
3
4
5
6

Col
d
wat
er
flow
(l/m Cold water mass
flowrate (kg/s)
in)

1,0
9
1,1
1
1,1
2
1,1
1
1,1
1
1,1
1

Cold
water
temper
ature in
(C)

Cold
water
temper
ature
out (C)

Heat
Gener
ated
(Kwatt
)

Heat
Quantit
y
(theore
tical)
(W)

Heat
quantity
(experimen
tal)(W)

1,80E-02

31,11

32,30

0,09

89,86

87,70

1,84E-02

31,05

32,30

0,10

96,12

87,90

1,85E-02

30,86

32,23

0,11

106,30 88,90

1,84E-02

30,99

32,30

0,10

100,73 89,30

1,84E-02

30,92

32,30

0,11

106,11 89,80

1,84E-02

30,92

32,23

0,10

100,73 90,20
44

7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33

1,0
8
1,0
8
1,0
8
1,0
8
1,1
1
1,0
8
1,1
1
1,1
2
1,1
1
1,1
2
1,1
1
1,1
2
1,1
1
1,1
1
1,0
8
1,0
9
1,0
9
1,0
8
1,0
8
1,0
8
1,0
8
1,0
8
1,0
8
1,0
8
1,0
9
1,0
9
1,0

1,79E-02

30,99

32,30

0,10

98,01

90,60

1,79E-02

30,92

32,23

0,10

98,01

90,40

1,79E-02

30,99

32,30

0,10

98,01

90,70

1,79E-02

30,86

32,23

0,10

102,50 90,60

1,84E-02

30,99

32,17

0,09

90,74

91,20

1,79E-02

31,05

32,30

0,09

93,52

91,40

1,84E-02

30,80

32,30

0,12

115,34 91,70

1,85E-02

31,05

32,23

0,09

91,55

1,84E-02

30,92

32,30

0,11

106,11 92,20

1,85E-02

30,99

32,23

0,10

96,21

1,84E-02

30,80

32,23

0,11

109,96 93,00

1,85E-02

30,99

32,23

0,10

96,21

93,60

1,84E-02

30,99

32,23

0,10

95,35

93,70

1,84E-02

30,92

32,23

0,10

100,73 93,80

1,79E-02

30,99

32,17

0,09

88,28

93,80

1,80E-02

30,99

32,17

0,09

89,10

94,00

1,80E-02

30,99

32,23

0,09

93,63

94,00

1,79E-02

30,92

32,23

0,10

98,01

94,30

1,79E-02

30,86

32,23

0,10

102,50 94,20

1,79E-02

31,05

32,11

0,08

79,31

1,79E-02

30,73

32,23

0,11

112,22 94,20

1,79E-02

30,99

32,17

0,09

88,28

94,30

1,79E-02

30,92

32,23

0,10

98,01

94,40

1,79E-02

30,80

32,30

0,11

112,22 94,60

1,80E-02

30,86

32,17

0,10

98,92

1,80E-02
1,79E-02

30,92
30,80

32,17
32,17

0,09
0,10

94,39 94,60
102,50 94,60

91,80

92,80

93,90

94,50

45

34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59

8
1,0
8
1,1
2
1,1
1
1,1
1
1,1
1
1,1
2
1,1
2
1,1
1
1,1
2
1,0
8
1,0
9
1,1
1
1,1
2
1,0
9
1,0
8
1,0
8
1,1
2
1,0
9
1,1
1
1,1
1
1,1
1
1,1
1
1,1
1
1,1
1
1,0
8
1,0
8

1,79E-02

30,73

32,17

0,11

107,74 94,90

1,85E-02

30,92

32,17

0,10

96,98

1,84E-02

30,86

32,17

0,10

100,73 95,70

1,84E-02

30,80

32,23

0,11

109,96 95,90

1,84E-02

30,92

32,23

0,10

100,73 96,30

1,85E-02

30,80

32,23

0,11

110,95 96,50

1,85E-02

30,86

32,17

0,10

101,64 96,80

1,84E-02

30,92

32,17

0,10

96,12

1,85E-02

30,73

32,17

0,11

111,73 97,20

1,79E-02

30,86

32,17

0,10

98,01

97,00

1,80E-02

30,92

32,17

0,09

94,39

97,00

1,84E-02

30,80

32,17

0,11

105,35 97,30

1,85E-02

30,73

32,11

0,11

107,07 97,70

1,80E-02

30,86

32,11

0,09

94,39

97,80

1,79E-02

30,86

32,17

0,10

98,01

97,70

1,79E-02

30,80

32,17

0,10

102,50 97,40

1,85E-02

30,80

32,11

0,10

101,64 97,60

1,80E-02

30,80

32,11

0,10

98,92

1,84E-02

30,80

32,23

0,11

109,96 98,10

1,84E-02

30,86

32,11

0,10

96,12

1,84E-02

30,73

32,17

0,11

110,73 97,90

1,84E-02

30,86

32,11

0,10

96,12

98,10

1,84E-02

30,80

32,04

0,10

95,35

98,40

1,84E-02

30,80

32,11

0,10

100,73 98,90

1,79E-02

30,80

32,17

0,10

102,50 99,10

1,79E-02

30,73

32,17

0,11

107,74 99,00

95,40

97,00

98,00

98,10

46

60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86

1,0
8
1,0
8
1,0
8
1,0
8
1,0
8
1,0
8
1,0
9
1,0
8
1,0
8
1,0
9
1,1
2
1,1
2
1,1
2
1,1
2
1,1
1
1,1
1
1,0
9
1,0
9
1,0
9
1,0
8
1,0
8
1,0
8
1,0
8
1,0
8
1,0
8
1,0
9
1,0

1,79E-02

30,67

32,04

0,10

102,50 99,00

1,79E-02

30,80

32,11

0,10

98,01

98,80

1,79E-02

30,80

32,11

0,10

98,01

98,70

1,79E-02

30,67

32,11

0,11

107,74 98,90

1,79E-02

30,80

32,11

0,10

98,01

1,79E-02

30,67

32,11

0,11

107,74 99,00

1,80E-02

30,86

32,11

0,09

94,39

1,79E-02

30,80

32,17

0,10

102,50 99,20

1,79E-02

30,67

32,17

0,11

112,22 99,40

1,80E-02

30,73

32,11

0,10

104,20 99,60

1,85E-02

30,73

32,11

0,11

107,07 99,80

1,85E-02

30,73

32,11

0,11

107,07 100,10

1,85E-02

30,73

32,11

0,11

107,07 100,40

1,85E-02

30,67

32,04

0,11

106,30 100,60

1,84E-02

30,67

32,04

0,11

105,35 100,70

1,84E-02

30,61

32,11

0,12

115,34 101,10

1,80E-02

30,80

32,04

0,09

93,63

1,80E-02

30,67

32,04

0,10

103,45 100,80

1,80E-02

30,80

32,11

0,10

98,92

100,80

1,79E-02

30,73

32,04

0,10

98,01

100,30

1,79E-02

30,61

32,04

0,11

106,99 100,30

1,79E-02

30,73

32,04

0,10

98,01

1,79E-02

30,73

32,11

0,10

103,25 100,30

1,79E-02

30,61

32,17

0,12

116,71 100,40

1,79E-02

30,67

31,98

0,10

98,01

1,80E-02
1,79E-02

30,80
30,67

32,04
32,11

0,09
0,11

93,63 100,20
107,74 100,40

98,90

99,10

100,90

100,00

100,10

47

87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112

8
1,0
8
1,1
2
1,1
2
1,1
2
1,1
1
1,0
8
1,0
8
1,0
9
1,0
8
1,1
1
1,1
1
1,1
2
1,1
2
1,1
1
1,1
1
1,1
2
1,1
2
1,0
8
1,0
8
1,0
9
1,0
8
1,0
8
1,0
8
1,0
8
1,0
8
1,0
8

1,79E-02

30,54

32,04

0,11

112,22 101,00

1,85E-02

30,67

32,04

0,11

106,30 101,20

1,85E-02

30,67

32,04

0,11

106,30 101,40

1,85E-02

30,73

31,98

0,10

96,98

1,84E-02

30,73

32,04

0,10

100,73 101,70

1,79E-02

30,54

31,98

0,11

107,74 101,80

1,79E-02

30,61

32,04

0,11

106,99 101,90

1,80E-02

30,73

32,11

0,10

104,20 102,00

1,79E-02

30,67

32,11

0,11

107,74 102,40

1,84E-02

30,67

31,98

0,10

100,73 102,30

1,84E-02

30,67

31,98

0,10

100,73 102,70

1,85E-02

30,67

32,04

0,11

106,30 103,10

1,85E-02

30,67

31,98

0,10

101,64 103,20

1,84E-02

30,61

32,11

0,12

115,34 103,60

1,84E-02

30,54

32,04

0,12

115,34 103,90

1,85E-02

30,67

32,04

0,11

106,30 104,20

1,85E-02

30,67

31,98

0,10

101,64 104,40

1,79E-02

30,61

32,11

0,11

112,22 105,10

1,79E-02

30,48

31,98

0,11

112,22 105,20

1,80E-02

30,67

32,04

0,10

103,45 105,10

1,79E-02

30,67

32,04

0,10

102,50 105,10

1,79E-02

30,54

32,04

0,11

112,22 105,30

1,79E-02

30,61

32,11

0,11

112,22 105,90

1,79E-02

30,67

31,98

0,10

98,01

1,79E-02

30,54

32,04

0,11

112,22 106,00

1,79E-02

30,54

31,98

0,11

107,74 105,90

101,50

105,80

48

113
114
115
116
117
118
119
120
121
122

1,0
8
1,0
9
1,0
8
1,0
8
1,0
8
1,0
8
1,0
8
1,0
9
1,0
9
1,1
1

1,79E-02

30,54

32,04

0,11

112,22 106,00

1,80E-02

30,61

31,98

0,10

103,45 105,60

1,79E-02

30,67

32,04

0,10

102,50 105,50

1,79E-02

30,48

31,98

0,11

112,22 105,70

1,79E-02

30,61

32,04

0,11

106,99 105,90

1,79E-02

30,48

31,98

0,11

112,22 105,90

1,79E-02

30,54

31,98

0,11

107,74 105,80

1,80E-02

30,61

31,98

0,10

103,45 105,90

1,80E-02

30,61

31,98

0,10

103,45 105,70

1,84E-02

30,54

31,98

0,11

110,73 106,00

Cold
water
temper
ature in
[C]

Cold
water
temper
ature
out [C]

Heat
Gener
ated
(Kwatt
)

Heat
Quantit
y
(theore
tical)
(W)

30,61

32,69

0,16

155,62 162,1

30,54

32,69

0,16

160,86 162,4

30,48

32,81

0,17

174,32 162,4

30,61

32,75

0,16

161,59 162,5

30,67

32,75

0,16

157,06 162,3

30,54

32,81

0,17

171,41 162,6

30,61

32,75

0,16

160,11 162,7

30,54

32,81

0,17

169,83 163,1

30,67

32,75

0,16

157,06 162,7

30,61

32,81

0,17

166,12 162,7

30,48

32,75

0,17

171,41 162,8

30,48

32,75

0,17

169,83 162,7

Raw data for 10A


Col
d
wat
er
flow
Tim [l/m Cold water mass
e (s) in] flowrate (kg/s)
1,0
1
8
1,79E-02
1,0
2
8
1,79E-02
1,0
3
8
1,79E-02
1,0
4
9
1,80E-02
1,0
5
9
1,80E-02
1,0
6
9
1,80E-02
1,0
7
8
1,79E-02
1,0
8
8
1,79E-02
1,0
9
9
1,80E-02
1,0
10
9
1,80E-02
1,0
11
9
1,80E-02
1,0
12
8
1,79E-02

Heat
quantity
(experim
ental)
[W]

49

13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39

1,0
9
1,0
9
1,0
8
1,0
9
1,0
9
1,0
8
1,1
1,0
8
1,0
8
1,0
8
1,0
9
1,0
8
1,0
8
1,0
9
1,0
8
1,0
8
1,0
8
1,0
8
1,0
8
1,0
8
1,0
9
1,1
2
1,1
1
1,1
1
1,1
2
1,1
2
1,0
8

1,80E-02

30,67

32,81

0,16

161,59 162,4

1,80E-02

30,61

32,88

0,17

171,41 162,5

1,79E-02

30,67

32,88

0,17

165,34 162,4

1,80E-02

30,67

32,81

0,16

161,59 162,4

1,80E-02

30,67

32,88

0,17

166,88 162,8

1,79E-02
1,82E-02

30,54
30,61

32,81
32,81

0,17
0,17

169,83 163,3
167,64 163,1

1,79E-02

30,67

32,88

0,17

165,34 163,1

1,79E-02

30,48

32,88

0,18

179,56 163,9

1,79E-02

30,73

32,81

0,16

155,62 163,7

1,80E-02

30,67

32,88

0,17

166,88 163,8

1,79E-02

30,61

32,81

0,16

164,60 164,1

1,79E-02

30,61

32,81

0,16

164,60 164,2

1,80E-02

30,54

32,81

0,17

171,41 164,6

1,79E-02

30,73

32,94

0,17

165,34 164,5

1,79E-02

30,67

32,94

0,17

169,83 164,9

1,79E-02

30,61

32,94

0,17

174,32 165,3

1,79E-02

30,67

33,01

0,18

175,07 165,5

1,79E-02

30,61

32,88

0,17

169,83 165,8

1,79E-02

30,73

32,94

0,17

165,34 166

1,80E-02

30,67

32,88

0,17

166,88 166

1,85E-02

30,73

32,94

0,17

171,47 166,1

1,84E-02

30,67

33,01

0,18

179,93 166,6

1,84E-02

30,67

33,01

0,18

179,93 166,7

1,85E-02

30,67

33,01

0,18

181,56 167

1,85E-02

30,73

33,01

0,18

176,90 167,3

1,79E-02

30,73

32,94

0,17

165,34 167,2
50

40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66

1,0
9
1,1
1
1,1
2
1,1
1
1,1
2
1,1
1
1,1
2
1,1
2
1,1
2
1,1
2
1,1
2
1,1
1
1,0
8
1,1
2
1,0
9
1,0
8
1,0
8
1,0
9
1,1
2
1,1
2
1,1
2
1,0
8
1,1
1
1,1
2
1,0
9
1,0
8
1,1

1,80E-02

30,67

33,01

0,18

176,69 167,3

1,84E-02

30,61

32,94

0,18

179,17 168

1,85E-02

30,73

33,01

0,18

176,90 168,1

1,84E-02

30,73

33,01

0,18

175,32 168,5

1,85E-02

30,67

32,94

0,18

176,12 169

1,84E-02

30,8

33,01

0,17

169,94 169,1

1,85E-02

30,8

33,01

0,17

171,47 169,4

1,85E-02

30,73

33,07

0,18

181,56 169,9

1,85E-02

30,61

33,01

0,19

186,21 170,5

1,85E-02

30,8

33,07

0,18

176,12 170,8

1,85E-02

30,73

33,01

0,18

176,90 170,9

1,84E-02

30,73

33,07

0,18

179,93 171,2

1,79E-02

30,8

33,07

0,17

169,83 171

1,85E-02

30,61

33,07

0,19

190,87 171,3

1,80E-02

30,8

33,07

0,17

171,41 171,4

1,79E-02

30,8

33,07

0,17

169,83 171,4

1,79E-02

30,8

33,07

0,17

169,83 171,3

1,80E-02

30,73

33,07

0,18

176,69 171,3

1,85E-02

30,73

33,07

0,18

181,56 171,5

1,85E-02

30,73

33,07

0,18

181,56 171,8

1,85E-02

30,8

33,07

0,18

176,12 172,1

1,79E-02

30,73

33,07

0,18

175,07 172,3

1,84E-02

30,8

33,07

0,17

174,55 172,2

1,85E-02

30,67

33,07

0,19

186,21 172,7

1,80E-02

30,67

33,14

0,19

186,51 172,9

1,79E-02
1,84E-02

30,73
30,73

33,14
33,07

0,18
0,18

180,31 172,8
179,93 173
51

67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92

1
1,0
8
1,0
9
1,1
1
1,1
2
1,1
2
1,1
2
1,1
2
1,1
1
1,1
2
1,1
2
1,1
2
1,1
1
1,0
8
1,0
9
1,0
9
1,0
9
1,0
8
1,0
9
1,1
2
1,1
1
1,1
2
1,1
1
1,1
1
1,0
9
1,0
8
1,0
8

1,79E-02

30,8

33,07

0,17

169,83 173,1

1,80E-02

30,73

33,14

0,18

181,98 173,2

1,84E-02

30,8

33,14

0,18

179,93 172,9

1,85E-02

30,86

33,07

0,17

171,47 172,8

1,85E-02

30,86

33,14

0,18

176,90 173,2

1,85E-02

30,92

33,07

0,17

166,81 173,5

1,85E-02

30,92

33,14

0,17

172,24 173,8

1,84E-02

30,8

33,14

0,18

179,93 174,2

1,85E-02

30,73

33,2

0,19

191,64 174,4

1,85E-02

30,86

33,14

0,18

176,90 174,5

1,85E-02

30,8

33,14

0,18

181,56 175,1

1,84E-02

30,8

33,2

0,18

184,55 175,4

1,79E-02

30,73

33,14

0,18

180,31 175,5

1,80E-02

30,8

33,2

0,18

181,22 175,4

1,80E-02

30,86

33,14

0,17

172,16 175,4

1,80E-02

30,86

33,2

0,18

176,69 175,6

1,79E-02

30,86

33,14

0,17

170,58 175,4

1,80E-02

30,73

33,2

0,19

186,51 175,7

1,85E-02

30,92

33,2

0,18

176,90 176,1

1,84E-02

30,8

33,2

0,18

184,55 176,5

1,85E-02

30,86

33,2

0,18

181,56 176,8

1,84E-02

30,86

33,2

0,18

179,93 177,1

1,84E-02

30,8

33,2

0,18

184,55 177,1

1,80E-02

30,92

33,14

0,17

167,63 177,1

1,79E-02

30,8

33,27

0,18

184,80 177

1,79E-02

30,86

33,27

0,18

180,31 176,7
52

93
94
95
96
97
98
99

1,1
2
1,1
2
1,1
2
1,1
2
1,0
8
1,0
9
1,0
8

1,85E-02

30,8

33,14

0,18

181,56 176,6

1,85E-02

30,86

33,2

0,18

181,56 177,1

1,85E-02

30,86

33,27

0,19

186,99 177,2

1,85E-02

30,86

33,2

0,18

181,56 177,3

1,79E-02

30,8

33,27

0,18

184,80 177,3

1,80E-02

30,8

33,2

0,18

181,22 177,3

1,79E-02

30,86

33,2

0,18

175,07 177,2

Cold
water
temper
ature in
(C)

Cold
water
temper
ature
out (C)

Heat
Gener
ated
(Kwatt
)

Heat
Quantit
y
(theore
tical)
(W)

1,80E-02

31,17

35,07

0,29

294,49 304,80

1,80E-02

31,17

35,13

0,30

299,02 304,50

1,80E-02

31,05

35,07

0,30

303,55 304,20

1,85E-02

31,11

35,13

0,31

311,90 304,50

1,85E-02

31,17

35,07

0,30

302,59 304,50

1,85E-02

31,05

35,01

0,31

307,25 304,50

1,85E-02

31,11

35,07

0,31

307,25 304,70

1,85E-02

31,05

35,07

0,31

311,90 305,10

1,79E-02

31,05

35,13

0,31

305,25 305,10

1,79E-02

31,11

35,07

0,30

296,27 304,70

1,84E-02

31,05

35,07

0,31

309,12 304,80

1,80E-02

31,05

35,13

0,31

308,08 304,80

1,80E-02

31,17

35,13

0,30

299,02 304,70

1,80E-02

31,05

35,07

0,30

303,55 304,50

1,80E-02
1,80E-02

31,05
31,05

35,07
35,07

0,30
0,30

303,55 304,30
303,55 304,00

Raw data for 15A


Col
d
wat
er
flow
Time (l/m Cold water mass
(s)
flowrate (kg/s)
in)

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

1,0
9
1,0
9
1,0
9
1,1
2
1,1
2
1,1
2
1,1
2
1,1
2
1,0
8
1,0
8
1,1
1
1,0
9
1,0
9
1,0
9
1,0
9
1,0

Heat
quantity
(experimen
tal)(W)

53

17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42

9
1,0
9
1,1
2
1,0
9
1,1
2
1,1
2
1,1
2
1,1
1
1,1
2
1,1
2
1,1
1
1,1
1
1,0
8
1,1
2
1,1
2
1,1
1
1,1
1
1,1
2
1,1
2
1,1
2
1,1
2
1,1
2
1,1
2
1,1
2
1,1
1
1,0
9
1,0
8

1,80E-02

31,05

35,07

0,30

303,55 303,90

1,85E-02

31,11

35,07

0,31

307,25 304,50

1,80E-02

31,05

35,07

0,30

303,55 304,30

1,85E-02

31,05

35,07

0,31

311,90 304,80

1,85E-02

31,05

35,07

0,31

311,90 305,00

1,85E-02

31,05

35,07

0,31

311,90 305,40

1,84E-02

31,05

35,07

0,31

309,12 305,80

1,85E-02

31,05

35,07

0,31

311,90 306,20

1,85E-02

30,99

35,07

0,32

316,56 306,60

1,84E-02

30,99

35,07

0,31

313,73 307,00

1,84E-02

30,92

35,07

0,32

319,11 307,50

1,79E-02

30,99

35,07

0,31

305,25 307,60

1,85E-02

30,99

35,13

0,32

321,21 307,70

1,85E-02

30,99

35,07

0,32

316,56 308,00

1,84E-02

30,99

35,13

0,32

318,34 308,40

1,84E-02

30,99

35,07

0,31

313,73 308,80

1,85E-02

30,99

35,01

0,31

311,90 309,00

1,85E-02

30,92

35,01

0,32

317,33 308,90

1,85E-02

30,99

35,01

0,31

311,90 309,10

1,85E-02

30,99

35,07

0,32

316,56 309,30

1,85E-02

30,92

35,07

0,32

321,99 309,30

1,85E-02

30,86

35,07

0,33

326,64 309,80

1,85E-02

30,92

35,01

0,32

317,33 310,10

1,84E-02

30,99

35,01

0,31

309,12 310,60

1,80E-02

30,99

35,07

0,31

308,08 310,20

1,79E-02

30,99

35,13

0,31

309,74 310,10
54

43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69

1,0
8
1,0
9
1,0
9
1,0
8
1,0
8
1,0
8
1,0
8
1,0
9
1,1
1
1,1
2
1,0
9
1,0
9
1,0
9
1,0
9
1,0
8
1,0
9
1,0
9
1,0
9
1,0
9
1,0
8
1,0
9
1,0
9
1,0
9
1,0
8
1,0
9
1,0
9
1,0

1,79E-02

31,05

35,01

0,30

296,27 309,60

1,80E-02

30,92

35,07

0,31

313,36 309,40

1,80E-02

30,99

35,01

0,30

303,55 309,30

1,79E-02

30,99

35,07

0,31

305,25 309,20

1,79E-02

30,92

35,01

0,31

306,00 308,90

1,79E-02

30,99

35,07

0,31

305,25 308,60

1,79E-02

30,99

35,07

0,31

305,25 308,40

1,80E-02

30,92

35,01

0,31

308,83 308,50

1,84E-02

30,92

35,01

0,31

314,50 308,60

1,85E-02

30,92

35,01

0,32

317,33 309,10

1,80E-02

30,99

35,01

0,30

303,55 308,90

1,80E-02

30,92

35,01

0,31

308,83 308,70

1,80E-02

30,99

35,01

0,30

303,55 308,50

1,80E-02

30,92

35,01

0,31

308,83 308,40

1,79E-02

30,92

35,01

0,31

306,00 308,50

1,80E-02

30,99

35,01

0,30

303,55 307,90

1,80E-02

30,92

35,07

0,31

313,36 307,90

1,80E-02

30,86

34,94

0,31

308,08 308,00

1,80E-02

30,86

34,94

0,31

308,08 307,90

1,79E-02

30,92

35,01

0,31

306,00 307,80

1,80E-02

30,92

35,01

0,31

308,83 308,00

1,80E-02

30,86

34,94

0,31

308,08 308,10

1,80E-02

30,92

34,94

0,30

303,55 307,90

1,79E-02

30,92

35,01

0,31

306,00 308,10

1,80E-02

30,86

35,07

0,32

317,89 308,30

1,80E-02
1,80E-02

30,80
30,86

34,94
34,94

0,31
0,31

312,61 308,40
308,08 308,20
55

70
71

9
1,1
2
1,1
2

1,85E-02

30,92

35,01

0,32

317,33 308,50

1,85E-02

30,80

34,94

0,32

321,21 309,20

Cold
water
temper
ature in
(C)

Cold
water
temper
ature
out (C)

Heat
Gener
ated
(Kwatt
)

Heat
Quantit
y
(theore
tical)
(W)

1,84E-02

30,86

35,46

0,35

353,72 334,90

1,85E-02

30,92

35,39

0,35

346,82 335,80

1,79E-02

30,92

35,46

0,34

339,67 336,50

1,79E-02

30,92

35,46

0,34

339,67 336,50

1,80E-02

30,92

35,39

0,34

337,53 336,40

1,79E-02

30,99

35,46

0,33

334,43 336,50

1,80E-02

30,92

35,39

0,34

337,53 336,70

1,80E-02

30,92

35,46

0,34

342,81 337,00

1,80E-02

30,92

35,46

0,34

342,81 337,10

1,80E-02

30,99

35,46

0,34

337,53 337,30

1,79E-02

30,99

35,46

0,33

334,43 337,30

1,79E-02

30,99

35,52

0,34

338,92 337,70

1,80E-02

30,92

35,52

0,35

347,34 338,00

1,80E-02

30,99

35,46

0,34

337,53 338,30

1,79E-02

30,99

35,52

0,34

338,92 338,50

1,80E-02

30,99

35,59

0,35

347,34 338,80

1,80E-02

30,99

35,52

0,34

342,06 338,90

1,79E-02

30,99

35,52

0,34

338,92 338,70

1,79E-02

30,99

35,59

0,34

344,16 339,10

1,79E-02

30,99

35,59

0,34

344,16 339,10

Raw data for 19A


Col
d
wat
er
flow
Time (l/m Cold water mass
(s)
flowrate (kg/s)
in)

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20

1,1
1
1,1
2
1,0
8
1,0
8
1,0
9
1,0
8
1,0
9
1,0
9
1,0
9
1,0
9
1,0
8
1,0
8
1,0
9
1,0
9
1,0
8
1,0
9
1,0
9
1,0
8
1,0
8
1,0
8

Heat
quantity
(experimen
tal)(W)

56

21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47

1,0
9
1,0
9
1,0
9
1,0
8
1,0
9
1,0
9
1,0
9
1,0
9
1,0
8
1,0
9
1,0
8
1,0
8
1,0
9
1,1
1
1,1
1
1,1
1
1,1
2
1,1
2
1,1
1
1,0
9
1,1
2
1,0
9
1,1
2
1,1
2
1,1
2
1,1
2
1,1

1,80E-02

31,05

35,52

0,34

337,53 339,00

1,80E-02

31,05

35,52

0,34

337,53 339,00

1,80E-02

30,99

35,65

0,35

351,87 339,40

1,79E-02

30,99

35,59

0,34

344,16 339,50

1,80E-02

30,99

35,59

0,35

347,34 339,80

1,80E-02

30,99

35,65

0,35

351,87 340,00

1,80E-02

30,92

35,52

0,35

347,34 340,20

1,80E-02

31,05

35,59

0,34

342,81 340,30

1,79E-02

31,05

35,59

0,34

339,67 340,30

1,80E-02

31,05

35,59

0,34

342,81 340,50

1,79E-02

31,11

35,59

0,34

335,18 340,70

1,79E-02

31,05

35,65

0,34

344,16 341,00

1,80E-02

31,05

35,65

0,35

347,34 341,20

1,84E-02

31,11

35,65

0,35

349,10 341,60

1,84E-02

31,05

35,65

0,35

353,72 342,30

1,84E-02

31,05

35,59

0,35

349,10 342,80

1,85E-02

31,05

35,65

0,36

356,90 343,60

1,85E-02

31,05

35,65

0,36

356,90 344,10

1,84E-02

31,11

35,65

0,35

349,10 344,60

1,80E-02

31,05

35,71

0,35

351,87 345,00

1,85E-02

31,05

35,65

0,36

356,90 345,60

1,80E-02

31,05

35,65

0,35

347,34 345,60

1,85E-02

31,05

35,71

0,36

361,56 346,30

1,85E-02

31,11

35,65

0,35

352,25 346,90

1,85E-02

31,11

35,71

0,36

356,90 347,50

1,85E-02
1,84E-02

31,05
31,11

35,71
35,71

0,36
0,35

361,56 348,30
353,72 348,70
57

48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73

1
1,0
9
1,0
8
1,0
8
1,0
9
1,0
9
1,0
9
1,0
9
1,0
9
1,0
8
1,0
9
1,0
8
1,0
9
1,0
9
1,0
9
1,1
2
1,0
9
1,0
9
1,0
9
1,0
8
1,0
9
1,0
8
1,0
8
1,0
9
1,0
9
1,0
9
1,0
9

1,80E-02

31,05

35,71

0,35

351,87 348,90

1,79E-02

31,05

35,65

0,34

344,16 348,60

1,79E-02

31,11

35,65

0,34

339,67 348,40

1,80E-02

31,11

35,78

0,35

352,63 348,40

1,80E-02

31,17

35,71

0,34

342,81 348,00

1,80E-02

31,11

35,78

0,35

352,63 347,90

1,80E-02

31,11

35,71

0,35

347,34 347,90

1,80E-02

31,11

35,78

0,35

352,63 348,00

1,79E-02

31,17

35,78

0,34

344,90 348,00

1,80E-02

31,11

35,71

0,35

347,34 348,00

1,79E-02

31,11

35,78

0,35

349,39 348,00

1,80E-02

31,11

35,71

0,35

347,34 348,00

1,80E-02

31,05

35,78

0,36

357,16 347,90

1,80E-02

31,11

35,78

0,35

352,63 348,00

1,85E-02

31,11

35,78

0,36

362,33 348,50

1,80E-02

31,11

35,78

0,35

352,63 349,10

1,80E-02

31,11

35,84

0,36

357,16 349,30

1,80E-02

31,11

35,78

0,35

352,63 349,10

1,79E-02

31,05

35,84

0,36

358,37 349,40

1,80E-02

31,17

35,84

0,35

352,63 349,60

1,79E-02

31,17

35,84

0,35

349,39 349,60

1,79E-02

31,11

35,84

0,35

353,88 350,00

1,80E-02

31,11

35,84

0,36

357,16 350,20

1,80E-02

31,17

35,84

0,35

352,63 350,30

1,80E-02

31,17

35,78

0,35

348,10 350,50

1,80E-02

31,11

35,78

0,35

352,63 350,60
58

74
75
76
77
78
79
80
81

1,1
2
1,1
1
1,1
2
1,1
2
1,1
2
1,1
2
1,1
2
1,1
2

1,85E-02

31,17

35,84

0,36

362,33 351,20

1,84E-02

31,17

35,84

0,36

359,10 351,90

1,85E-02

31,17

35,84

0,36

362,33 352,50

1,85E-02

31,17

35,91

0,37

367,77 353,20

1,85E-02

31,11

35,84

0,37

366,99 353,60

1,85E-02

31,17

35,91

0,37

367,77 354,30

1,85E-02

31,24

35,84

0,36

356,90 354,80

1,85E-02

31,17

35,91

0,37

367,77 355,50

13.3.Part Raw data for Rate Law


The rest is available on request
Stack
volta
ge
[V]
V

17,9
1
17,7
7
17,8
2
17,9
5
18,0
1
18,0
1
17,8
7
18,1
1
18,0
7
18,1
2
18,1
8
18,1
0
18,1
9
17,9
9

Curre
nt
densit
y
(A/cm Current density
2)
ln(A/cm2)

0,4827
5
5,55
0,4885
83
5,45

Theoretical Current density using


reduced BV eq

1,713797928

4,618916835

1,695615609

4,879973577

0,4865
0,4810
83
0,4785
83
0,4785
83
0,4844
17
0,4744
17
0,4760
83

5,26

1,660131027

4,785087166

5,35

1,677096561

4,546927704

5,16

1,640936579

4,441042288

5,26

1,660131027

4,441042288

5,16

1,640936579

4,692045731

4,77

1,562346305

4,270017692

4,67

1,541159072

4,33762265

0,474

4,67

1,541159072

4,253281734

0,4715
0,4748
33
0,4710
83
0,4794
17

4,47

1,497388409

4,154234523

4,77

1,562346305

4,286819502

4,47

1,497388409

4,137952367

4,77

1,562346305

4,476060576
59

18,2
1
18,1
8
18,1
2
18,2
4
18,2
7
18,2
0
18,2
6
18,2
0
18,0
9
18,3
0
18,2
5
18,3
0
18,2
5
18,1
2
18,3
1
18,2
5
18,1
5
18,1
4
18,3
1
18,1
5
18,3
5
18,2
6
18,2
0
18,2
6
18,1
8
18,3
4
18,2

0,4702
5
4,38

1,477048724

4,105579255

0,4715 4,47

1,497388409

4,154234523

0,474

4,67

1,541159072

4,253281734

0,469
0,4677
5
0,4706
67
0,4681
67
0,4706
67
0,4752
5

4,28

1,45395301

4,057493848

4,18

1,430311247

4,009971628

4,28

1,45395301

4,121734028

4,08

1,406096988

4,0257502

4,28

1,45395301

4,121734028

4,47

1,497388409

4,303687426

0,4665 3,99
0,4685
83
4,08

1,383791231

3,963005997

1,406096988

4,041590859

0,4665 3,99
0,4685
83
4,18

1,383791231

3,963005997

1,430311247

4,041590859

0,474
0,4660
83
0,4685
83
0,4727
5
0,4731
67
0,4660
83
0,4727
5
0,4644
17
0,4681
67
0,4706
67
0,4681
67

4,38

1,477048724

4,253281734

3,89

1,358409158

3,947473345

4,28

1,45395301

4,041590859

3,99

1,383791231

4,203466405

4,08

1,406096988

4,220006347

3,79

1,332366019

3,947473345

4,28

1,45395301

4,203466405

3,79

1,332366019

3,885949143

3,99

1,383791231

4,0257502

4,28

1,45395301

4,121734028

3,99

1,383791231

4,0257502

0,4715 4,08
0,4648
33
3,69
0,4677 3,89

1,406096988

4,154234523

1,305626458
1,358409158

3,901239708
4,009971628
60

7
18,2
3
18,2
0
18,3
1
18,2
7
18,1
4
18,3
4
18,1
6
18,1
6
18,2
3
18,2
5
18,1
8
18,1
2
18,1
2
18,2
5
18,2
0
18,0
7
18,2
4
18,1
6
18,1
2
18,1
4
18,1
0
18,0
0
18,1
0
18,0
5
18,1
8
18,1
4

5
0,4694
17
0,4706
67
0,4660
83
0,4677
5
0,4731
67
0,4648
33
0,4723
33
0,4723
33
0,4694
17
0,4685
83

4,08

1,406096988

4,073459413

3,89

1,358409158

4,121734028

3,69

1,305626458

3,947473345

3,89

1,358409158

4,009971628

3,99

1,383791231

4,220006347

3,69

1,305626458

3,901239708

3,79

1,332366019

4,186991289

4,08

1,406096988

4,186991289

3,89

1,358409158

4,073459413

3,79

1,332366019

4,041590859

0,4715 4,08

1,406096988

4,154234523

0,474

4,28

1,45395301

4,253281734

0,474
0,4685
83
0,4706
67
0,4760
83
0,469

3,79

1,332366019

4,253281734

3,89

1,358409158

4,041590859

3,99

1,383791231

4,121734028

4,18
3,79

1,430311247
1,332366019

4,33762265
4,057493848

0,4723
33
3,99

1,383791231

4,186991289

0,474 4,18
0,4731
67
3,99
0,4748
33
4,18

1,430311247

4,253281734

1,383791231

4,220006347

1,430311247

4,286819502

0,479 4,08
0,4748
33
4,18
0,4769
17
3,89

1,406096988

4,458517052

1,430311247

4,286819502

1,358409158

4,37182546

0,4715 3,79
0,4731
67
3,99

1,332366019

4,154234523

1,383791231

4,220006347
61

18,0
6
18,1
1
18,0
4
18,1
8
17,9
7
18,1
1
18,0
4

0,4765 4,28
0,4744
17
4,18
0,4773
33
3,89

1,45395301

4,354690475

1,430311247

4,270017692

1,358409158

4,389027867

0,4715
0,4802
5
0,4744
17
0,4773
33

3,89

1,358409158

4,154234523

4,18

1,430311247

4,511354989

4,08

1,406096988

4,270017692

4,18

1,430311247

4,389027867

13.4. Mass Balance Calculations


Mass balance
1. Temperature
T (K) = T (0C) +273
2. Total charge

3. Total charge (across 24 plates)


4. Number of electrons

5. Moles of electrons

6. Moles of Hydrogen

7. Molar flow of Hydrogen

8. Volumetric flow rate of Hydrogen (per minute)

13.5.Energy balance Calculations


62

1. Mass flow rate of water


2. Heat loss

13.6. Rate Law calculations


Number of plates (N) = 24
Area per plate = 0.013m2
Total area (A total) = 24 x 0.013 = 0.312m2
1. Temperature
T (K) = T (oC) +273
2. Overpotential

3. Current density

4. Theoretical current density

63

Vous aimerez peut-être aussi