FEATURES

Shown with
Optional
Equipment
FULL RANGE OF ATTACHMENTS
- Wide range of bolt-on system expansion
attachments.; Jacto ry designed and tested
SINGLE-SOURCE SUPPLIER
Complete syste rnsdesig(led andbuHtat
Caterpillar ISO cert:ified''fc;lciHties ..
- Certified Prototype Tested with torsional
analysis
WORLDWIDE PRODUCTSUPPORT
thro ug hthe
CaterpiUardealernetWor:k
With over 1,200 dealerolJtlets operating
in 166 countries, you're never far from
the CaterpiHar part you need.
- of partsordersfiUedwithin
48 hours. The best product support
record in the industry.
- Caterpilla(dealerserviceteGhn icians are
trained aSPect ofyour
electric power generationsystern.
- Preventive maintenance agreements
- The Cat Scheduled Oil Sampling
(S-O-SSM)prograincosteffectiveJy detects
internal eng'ine compbnentcondition,
even the presence of unwanted fluids and
combustion by-products
MEETS OR EXCEEDS INTERNATIONAL
SPECIFICATIONS: ASGSM TIV1$,
AS 1359, AS2789,
BS5514, DIN6271, DIN6280,EGSA101P,
lEe 34/1, 1503046/1,1508528,
JEM1359, NEMA MG1, VED0530,
89/392/EEC,89/336/EEC
CATe 3508BDIESELENGINE
- Reliable, rugged, durable design
- Field-proven in thousands of
applications
- Four-stroke-cycle diesel. engjnecombines
consistent perfo rma nceand exce fie nt
fuel economy with minimum weight
Generator
Set
Prime Power
Caterpillar is leading the power generation
marketplace with Package Generator Sets
engineered to deliver unmatched flexibility,
expandability, reliability, and cost-effectiveness.
CAT
e
SR4B GENERATOR
- Designed to match performance and
output characteristics of Caterpillar
diesel engines
- Optimum winding pitch for minimum
total harmonic distortion and maximum
efficiency
- Segregated AC/DC, low voltage accessory
box provides single point access to
accessory connections
CAT
e
CONTROL PANELS
-Four levels of controls, designed to meet
individual customer needs.
- Switchgear conversion using Caterpillar
electronic monitoring system provides
state-of-the-art engine monitoring and
protection while providing a simple
interface to separate floorstB(lding

- Microprocessor based Electronic
Modular Control Panel (EMCP II and
11+) use digital metering and true
RMS monitoring to provide advanced
monitoring, metering, control, and
protective relaying capabilities. Fully
compatible with Caterpillar
annunciators, and remote
communication and expansion modules.
- EMCP 11+ paralleling panel provides fully
automatic and manual permissive
paralleling capability. Synchronizing and
load sharing are added to EMCP 11+
power metering and protective relaying
to provide a state-of-the,..art paralleling
system which is self contained within
the generator set.
CE
C.ATERPILLAR 1000kV.AGENERATOR SET
FACTORY INSTALLED STANDARD & OPTIONAL EQUIPMENT
SYSTEM STANDARD OPTIONAL
Air' inlet modular air cleaner, single dual element air cleaner
element heavy-duty air cleaner
service indicator air inlet shutoff
Cooling radiator with guard radiator duct flange
coolant drain line with valve jacket water heater with isolation valves
/
fan and belt guards
Caterpillar Extended Life Coolant
low coolant level shutdown
Exhaust stainless steel exhaust flex and industrial grade muffler and ANSI weld

"'"'
ANSI weld flange flanges
engine exhaust guarding residential muffler and ANSI weld flanges
critical muffler and ANSI weld flanges
muffler mounting kit, through-wall
installation kit
Fuel primary fuel filter fuel cooler

. secondary fuel filter water separator


fuel priming pump low fuel level alarm and.shutdown
flexible fuel lines
Generator permanent magnet excitation D.V.R. with KVAR/PF control
Digital Voltage Regulator (D.V.R.) bearing temperature detectors
class F temperature rise oversize and premium generators
105
0
C (221
0
F) prime circuit breaker, IEC compliant
anti-condensation space heater 3"polewith shunt trip
stator temperature detectors circuit breaker, IEC compliant, 4-pole
(type-J thermocouples) with shunt trip
q
Governor ADEM control system load sharing

Control panels EMCP II switchgear conversion
EMCP 11+
system expansion modules
Lube lubricating oil sump pump manual
oil drain line with valves sump pump and prelube manual
fumes disposal sump pump and prelube 24VDC
lube oil level regulation system
lube oil high temperature shutdown
Mounting 13-in. structural steel rails
spring-type anti-abrasion isolators
Startingl 45 amp charging alternator integral 5 amp battery charger
charging fuel shutoff solenoid oversize batteries
24 volt starting motor ether starting aid'
batteries with rack and cables heavy-duty starting system
battery disconnect
Other CE certification
crankcase explosion relief valves
1000kV.A GENERATOR SET
TECHNICAL DATA
1000 kVA/800 kW;Prime Power Generator Set - 1500 rpm/50 Hz
Power rating @ 0.8 PF with fan
kV-A I
1000
kW / 800
Fuel COflSUIr11PltIOn
100% Load with Fan L/hr / .
75% Load with Fan L/hr ",/
Cooling System
Ambient Air Temperature T.M.I.)
Designed for operation up to
Air Flow Restriction (After Radiator)
Standard Radiator Arrangement Data
AirFlow (Max @ Rated Speed)
Engine Cbolant Capacity with Radiator Y"
Engine Cqolant Capacity without Radiator
System
Combustion AlrlnletFlow Hate
Exhaust Gas Stack Temperature
Exhaust Gas Flow Rate
Exhaust Flange Size - {J nterna1< Diameter)
System Backpressure Altdwabte)
Deg C
kPa
m3/min
Deg C
m3/min
mm
kPa
43
.19
1146
336 -
103
64.8
428
158.9
203
6.7
Heat Rejection
Heat Rejection toCaclant (Total) kW 393
Heat ReJection to Exhaust (Total) kW 691
Heat Rejection to Atmosphere from Engine kW 95
Heat Rejection to Atmosphere from Generator kW 44
Deration: Generator set is designed to operate in c;mbient up to 43
0
C (109
0
F) and at higher
altitudes. Please consult factory for available outputs.
CAT8 693 FRAME GENERATOR
SPECIFICATIONS
Type ......... Permanent magnet excited, static
regulated, brushless
Construction ....... Two bearing, close coupled
Three phase ............ 12 lead reconnectable
Insulation .......... Class H with tropicalization
and antiabrasion
Enclosure ..................... Drip proof IP22
Alignment.......................... Pilot shaft
Overspeed capability .................... 150%
Wave form............. Less than 5% deviation
Paralleling capability................. Standard
Voltage regulator .. 3-phase sensing with D.V.R.
Voltage regulation .. Less than 1/2% (steady state)
Less than 1% (no load to full load)
Voltage gain ........ Adjustable to compensate
for line loss
TIF .............................. Less than 50
THD ............................ Less than 5%
i
?jo
"
.
..
CAT8 3508B ENGINE
SPECIFICATIONS
V-s, 4-Stroke-Cycle Watercooled Diesel
Bore - mm (in) .................. 170 (6.7)
Stroke - mm (in) ................. 190 (7.5)
Displacement - L (cu in) ......... 34.5 (2105)
Compression ratio. . . . . . . . . . . . . . . . . . .. 14: 1
Aspiration .......... Turbocharged, Separate
Circuit Aftercooled
Fuel System ............ Direct Unit Injection
CAT(!!I CONTROL PANEL
24 Volt DC Control
NEMA 1, IP22 enclosure
Electrically dead front
Lockable hinged door
Generator instruments meet ANSI C-39-1
Terminal box mounted
Single location customer connector point
EC compliant - segregated AC/DC connection
Consult your Caterpillar dealer for available
voltages.
1000 kVA GENERATOR SET
PRIME POWER GENERATOR SET PACKAGE - TOP VIEW
@
Fuel Inlet
8
Oil Filter

Control and Power Panel

Excess Fuel Return
V
Air Cleaner
@)
Conduit Entrance
S
Fuel Filter
9
Exhaust
PACKAGE DIMENSIONS
Length mm(in)
Width mm (in)
Height mm(in)
Shipping Weight kg (Ib)
5246(207)
1752 (69)
2230.(88)
9060 (19 960)
Note: General configuration not to be used for
installation. See general dimension
,,'
drawings for detail.
RATING DEFINITIONS AND CONDITIONS
Prime Output available with varying load for Fuel rates are based on fuel oil of 35API (16C
an unlimited time. Prime power in accordance or 60 F) gravity having an LHV of 42 780 kJ/kg
with IS08528. 10% overload power in (18390 8tu/lb) when used at 29C (85F) and
accordance with IS03046/1, AS2789, DIN6271, weighing 838.9 g/Iiter (7.001 Ibs/U.S. gal.).
and 8S5514 available on request.
Additional ratings may be available for specific
Ratings are based on SAE J1349 standard customer requirements. Consult your
conditions. These ratings also apply at Caterpillar representative for details.
IS03046/1, DIN6271, and 8S5514 standard
conditions.
Materials and specifications are subject to change without notice. The International System of Units (51) is used in this publication.
LEHX7637-02 Printed in U.S.A. 1998 Caterpillar Inc.