Vous êtes sur la page 1sur 2

Boise Cascade

EWP TECHNICAL NOTE

Weights of Building Materials [psf]


CEILING
Acoustical fiber tile (1)
Suspended steel channel system (1)
2x8 ceiling joists @ 16" o.c., R-49
insulation, 1/2" gypsum board
1 Plaster
ROOF
Fiberglass shingles
Asphalt shingles (1)
Wood shingles (1)
Spanish clay tile (1)
Composition Roofing:
Three-ply ready roofing (1)
Four-ply felt and gravel (1)
Five-ply felt and gravel (1)
20 gage metal deck (1)
18 gage metal deck (1)
1" fiberglass batt insulation
1" loose fiberglass insulation
1" loose cellulose insulation
1" rigid insulation (1)
3/16" slate (1)
1/4" slate (1)
Single-ply (no ballast) (1)
Single-ply (ballasted)
Dry gravel (1)
2x8 rafters @ 16" o.c., fiberglass
shingles, 15# felt, 3/8" sheathing
Skylight: metal frame w/ 3/8 wire glass

1
2
7
8
3
2
3
19
1
5.5
6
2.5
3
0.04
0.04
0.14
1.5
7
10
0.7
11
8.7
8
8

(1)

FLOOR
1" reinforced regular weight concrete
1" plain lightweight concrete (1)
7/16" cementitious backerboard
Ceramic or quarry tile (3/4") on 1/2"
mortar bed (1)
Ceramic or quarry tile (3/4") on 1" mortar
bed (1)
1" mortar bed
1" slate (1)
3/8" marble tile
3/8" ceramic floor tile (1)
Hardwood flooring, 7/7-in (1)
1/4 linoleum or asphalt tile (1)
BCI joists @ 16" o.c., 3/4" sheathing,
1/2" gypsum board
3/4" Gyp-Crete topping

Tech Note GE-1

12.5
8
3
16
23
12
14.3
6
4.7
4
1
10

Waterproofing Membranes
Bituminous, smooth surface (1)
Liquid applied (1)

1.5
1

SHEATHING
3/8" Plywood or OSB
1/2" Plywood or OSB
5/8" Plywood or OSB
3/4" Plywood or OSB
7/8 Plywood or OSB
1 1/8 Plywood or OSB
1/2" gypsum board (1)
5/8" gypsum board (1)
1/2" cementitious backerboard
1-1/2" softwood T & G decking

1.2
1.7
2.1
2.5
2.9
3.8
2.2
2.75
3
4.6

FRAMING
2x4 @ 16" o.c.
2x6 @ 16" o.c.
2x8 @ 16" o.c.
2x10 @ 16" o.c.
2x12 @ 16" o.c.
BCI 400 or 400s @ 12" o.c.
BCI 400 or 400s @ 16" o.c.
BCI 400 or 400s @ 19.2" o.c.
BCI 400 or 400s @ 24" o.c.
BCI 450 or 450s @ 12" o.c.
BCI 450 or 450s @ 16" o.c.
BCI 450 or 450s @ 19.2" o.c.
BCI 450 or 450s @ 24" o.c
BCI 500 or 500s @ 12" o.c.
BCI 500 or 500s @ 16" o.c.
BCI 500 or 500s @ 19.2" o.c.
BCI 500 or 500s @ 24" o.c
BCI 600s @ 12" o.c.
BCI 600s @ 16" o.c.
BCI 600s @ 19.2" o.c.
BCI 600s @ 24" o.c.
BCI 650 @ 12" o.c.
BCI 650 @ 16" o.c.
BCI 650 @ 19.2" o.c.
BCI 650 @ 24" o.c
BCI 90XL or 900s @ 12" o.c.
BCI 90XL or 900s @ 16" o.c.
BCI 90XL or 900s @ 19.2" o.c.
BCI 90XL or 900s @ 24" o.c.

1.1
1.7
2.2
2.9
3.5
1.8 - 2.6
1.4 2.0
1.1 - 1.6
0.9 - 1.3
1.9 3.1
1.4 - 2.3
1.2 - 1.9
1.0 1.6
2.1 2.9
1.6 2.2
1.3 1.8
1.1 1.5
3.0 3.5
2.3 - 2.6
1.9 - 2.2
1.5 - 1.8
2.7 3.7
2.0 2.8
1.7 2.3
1.4 1.9
3.7 4.6
2.8 3.5
2.3 2.9
1.9 2.3

6.5

Page 1 of 2

revised 5/01

Boise Cascade
EWP TECHNICAL NOTE
WALL
5/16" x 7-1/2" fiber cement lap siding
4" clay brick (1)
3-7/8" hollow glass block (1/4" mortar)
1/4" ceramic wall tile (1)
2x4 studs @ 16" o.c., 5/8" gypsum,
insulation, 3/8" siding (1)
2x6 studs @ 16" o.c., 5/8" gypsum,
insulation, 3/8" siding (1)
Wood or steel studs, 1/2" gypsum board
each side (1)
Exterior stud walls w/ brick veneer (1)
Windows: glass, frame and sash (1)
10 diameter log wall
MISCELLANEOUS
1" of water
Hay: bales stacked 10 high

3
39
20
3.1
11
12
8
48
8
26
5.2
150

Include at least 1.5 psf in all dead


load summations to account for
incidentals such as plumbing, ducts,
light fixtures, etc.
(1) Minimum Design Loads for Buildings and Other
Structures, ASCE 7-98

Tech Note GE-1

Page 2 of 2

revised 5/01

Vous aimerez peut-être aussi