S.No Description Units Qty Rate (In Rs) Amount (In Rs.)
A)
FIRE, HYDRANT SYSTEM NOTE :- A Rates quoted shall be inclusive of all structural supports, and clamps as per approved design.
Providing and fixing black steel pipes to IS 1239/3589 heavy class including all fittings like anchor fasteners, couplings, bends, elbows, tees, flanges, etc., welding as required painting with one coat of red-oxide primer and two or more coats of synthetic enamel paints to give an even shade, cutting holes and chases in brick or RCC walls and making good complete. A B C D E 200 mm dia. 150 mm dia. 100 mm dia. 80 mm dia. 25 mm dia. Providing and fixing cast iron sluice valves with epoxy coated disc, carbon steel shaft and lever actuator tested to 10 Kg-/cm 2. 200 mm dia 150 mm dia Providing and fixing cast iron butterfly valves with epoxy coated disc, carbon steel shaft and lever actuator tested to 16 Kg-/cm 2. 100 mm dia 80 mm dia Providing and fixing cast iron double flanged horizontal type non return valves including nuts, bolts, 1.5 mm thick compressed asbestos gasket complete. 150 mm dia 100 mm dia Meter Meter Meter Meter Meter 10 198 60 40 15
A B 3
Each
2 5
A B 4
Each Each
3 2
A B
Each Each
ADDITIONS _____________
3 2
OVER WRITINGS______________
CUTTINGS _____________
Z O N A L O F F I C E B U I L D I N G F O R B A N K O F I N D I A A T S E C T O R -3 1 - A , C H A N D IG A R H
S.No 5
Description Supply, Installation, Testing & Commissioning Of :Single headed, Gun-metal ISI marked oblique pattern hydrant landing valve with 80 mm dia flanged inlet and 63 mm dia instantaneous type female outlet complete with gunmetal cap and G.I. chain, twist release type plug and all accessories as per 13:5290-1983 (Type 'A') First-Aid Fire Hose Reel wall mounting swinging type complete with drum, bracket, 25 mm dia. ball valve and 20 mm dia.x 36M long high pressure Hose Reel tubing as per IS:444 & ISI marked with Gunmetal shut-off nozzle having 5mm dia. orifice. The Hose Reel shall strictly confirm to IS : 884-1985. Non-percolating flexible hose (RRL type-'A') ISI marked (IS:636) 63 mm dia x 15 M long complete with instantaneous type gunmetal 63 mm dia. IS marked Male and female couplings (IS:903) bound and riveted to hose pipe with copper rivets and 1.5 mm copper wire. Gun-metal 63mm dia short size branch pipes with 20 mm dia nozzles with 63mm instantaneous coupling ISI marked (IS: 903). Providing and fixing fire hose cabinet fabricated from 16 gauge MS sheet of fully welded construction with flanged double front door with locking arrangements and partially glazed with 4 mm thick glass, stove enameled fire red finish with fire hose written on front suitable to house , 2 x 1 5 m canvas hose with couplings, one branch pipe ,one fire man's axe and First aid hose reel size 760 x 1,500x 600 (for internal hydrants) and design to be approved by engineer in charge.
Units Each
Qty 17
Each
17
Each
34
Each
17
Each
15
CUTTINGS _____________
ADDITIONS _____________
OVER WRITINGS______________
Z O N A L O F F I C E B U I L D I N G F O R B A N K O F I N D I A A T S E C T O R -3 1 - A , C H A N D IG A R H
S.No 10
Description Providing and fixing fire hose cabinet fabricated from 16 gauge MS anodised aluminium sheet with single or double glazed front door and locking arrangements, painted "FIRE HOSE" written on front including necessary supports approximate size 750 mm x 600 mm x 300 mm deep. Design to be approved by engineer in charge. (for external hydrants). Providing and fixing 100mm dia twoway fire brigade inlet connection consisting of 63mm size instantaneously make coupling and shall be protected by cap scored with a chain glass bore etc. complete with one 100mm dia sluice valve and 100mm dia non-return valve (To be connected to main ring, main/wet riser/sprinkler riser) ( IS 904- 19765). Providing and fixing Gunmetal four way collecting head with 63 mm dia. Instantaneous type inlet with built in check valve and 150mm dia flanged outlet complete with bolts, nuts and rubber insertions for fire brigade connection to underground tanks. (IS 904 1965). Providing and fixing Gun-metal Fire Brigade Suction Hose coupling (Draw-out Connection) with nut for female coupling as per IS:902- 1974 complete with 100 mm dia. G.I. Suction pipe and 100 mm dia. 1No. C.I. Foot valve flanged (to be connected to static water tank). Providing and fixing M.S. cabinet fabricated from 16 g sheet with full front glass door and locking arrangement duly painted with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade and suitably mounted on a raised masonry platform as required (Approx.0.6mx0.6Mx0.45M). (FB Draw-out/ inlet connections)
Units Each
Qty 2
11
Each
12
Each
13
Each
14
Each
CUTTINGS _____________
ADDITIONS _____________
OVER WRITINGS______________
Z O N A L O F F I C E B U I L D I N G F O R B A N K O F I N D I A A T S E C T O R -3 1 - A , C H A N D IG A R H
S.No 15
Description Providing and fixing standard firemans axe with heavy insulated rubber handle (20,000 volts). Providing and fixing suction strainer with MS flanged connections 1000 mm long fabricated from 16 gauge brass sheet with 3 mm slots. A B 200 mm dia 100 mm dia Providing and fixing air cushion tank comprising of single acting heavy duty spring type brass air valve screwed to 300 mm dia and 900 mm long tank with dished ends, ball valves including painting both sides with zinc chromate primer complete. Providing and fixing CO2 type extinguishers with cylinder fully charged of the capacity of 4.5 Kg complete with backlite horn, discharge tube C.I. bracket for wall mounting etc., conforming to ISS 2876 or 2878. Providing and fixing Portable Chemical Water (gas pressure) type fire extinguishers with cylinder fully charged of the of 9 ltrs. Complete with backlit horn descharge type, CI bracket for wall mounting etc., confirming to relevant IS. Providing and fixing mechanical foam type fire extinguishers with cylinder fully charged of the capacity of 9 Kg complete with backlit horn, discharge type Cal brackets for wall mounting etc., conforming to relevant IS. Providing and fixing 'ABC' stored pressure type Dry Chemical Powder (Mono-Ammonium Phosphate ) fire extinguisher with fixing hangers, hose, brackets, screws to required size etc., complete as per IS:14609. TOTAL
Units Each
Qty 15
16
17
2 1 1
18
Each
15
19
Each
15
20
Each
21
Each
CUTTINGS _____________
ADDITIONS _____________
OVER WRITINGS______________
Z O N A L O F F I C E B U I L D I N G F O R B A N K O F I N D I A A T S E C T O R -3 1 - A , C H A N D IG A R H
S.No
Description
Units
Qty
B)
SPRINKLER SYSTEM NOTE :- A Rates quoted shall be inclusive of all structural supports, and clamps as per approved design.
Providing and fixing black steel pipe to IS 1239 heavy class complete with M.S. fittings like couplings, bends, Tees, flanges, etc., painting with one coat of red Oxide primer two or more coats of synthetic enamel paint to give an even shade of clamps, anchor fasteners, including cutting and making good the walls, etc. A B C D E F G H 150 mm dia. 100 mm dia. 80 mm dia. 65 mm dia. 50 mm dia. 40 mm dia. 32 mm dia. 25 mm dia. Providing and fixing 15 mm dia. pendent type chromium plated brass sprinkler head with quartzoid bulb and set to operate at 68 deg.C Providing and fixing. Control Valve assembly comprising of vertical wet alarm valve, including the cost of 150 mm dia butterfly valve, hydraulic alarm motor & gong, 15 mm dia. Test valve, 50 mm dia. Drain valve and all necessary trimming connections including 2 nos. pressure gauges as per manufacturer 's catalogue A 150 min dia. Providing and fixing M.S. cabinet fabricated from 16 GMS sheet with full front glass door and locking arrangement With suitable shelves for keeping 25 spare sprinklers and one spanner properly fixed in the shelves and cabinet painted fire red with stove enameled of approved shade size 900 x 600 x 150 mm.
ADDITIONS _____________
15 8 8 8 8 18 30 50 72
Each Each
1 1
CUTTINGS _____________
OVER WRITINGS______________
Z O N A L O F F I C E B U I L D I N G F O R B A N K O F I N D I A A T S E C T O R -3 1 - A , C H A N D IG A R H
S.No 5
Description
Units
Qty 2
Providing and fixing electrically operated flow indicating switches with threaded connection for a minimum flow of 90 lpm for indicating water flow in sprinkler branch line with necessary junction box installed in accessible place including 1.5 mm thick compressed asbestos gasket, nuts and bolts, nuts, complete. (wiring from switches to panel not included) Providing and fixing double flanged cast iron sluice valve class I with Wheel Complete with bolts, nuts, 3 mm thick rubber insertion complete conforming to IS 780. A B 150 mm dia 100 mm dia. Providing and fixing standard dial type pressure gauge with screwed inlet with isolation cock suitable for liquid gauge to show pressure upto 20 kg/sqcm. Providing and fixing Ball valve with hard chrome plated ball inside PTFE (Teflon) seat & ring with chrome plated centre handle with female BSP threads complete: in all respects. A 50 mm dia. Providing and laying 2 core 1.5 sqmm control cable between flow switches and panel. Providing and installing 16 gauge 20 mm dia MS conduit on surface or concealed in wall, false ceiling including cutting chasing making good the same as directed with junction boxes, bends, saddles and other accessories as required with red enamel paint for identification.
Each
1 1 2
Each Meter
3 100
10
Meter
50
CUTTINGS _____________
ADDITIONS _____________
OVER WRITINGS______________
Z O N A L O F F I C E B U I L D I N G F O R B A N K O F I N D I A A T S E C T O R -3 1 - A , C H A N D IG A R H
S.No 11
Description
Units
Qty 1
Providing and fixing Sprinkler Annunciation Panel for minimum 8 Zones (6 working + 2 standby) zones spare, compatible for seamless integration with water flow devices with visual display for all zones, complete with internal sounder, alarm/fault indications & standby 24v lead acid batteries with charger. (Note : The panel shall be located in the Fire control room and connected to flow indicating switches in sprinkler system). TOTAL
Each
CUTTINGS _____________
ADDITIONS _____________
OVER WRITINGS______________
Z O N A L O F F I C E B U I L D I N G F O R B A N K O F I N D I A A T S E C T O R -3 1 - A , C H A N D IG A R H
S.No
Description
Units
Qty
C)
1
FIRE DETECTION SYSTEM Supplying, fixing testing & commissioning dual chamber optical smoke detector with LED. Supplying, fixing testing & commissioning Temp-cum-Rate of rise type heat detectors. Supplying, fixing testing & commissioning flush type response indicator with red coloured LED lamp. Supplying, fixing testing & commissioning manual break glass units alongwith chain & hammer. Supplying, fixing testing & commissioning dual tone type electronics hooter suitable for fire and fault signaling and public address system. Supplying, fixing testing & commissioning 10 zone Main Control Panel with zone indication, 60 watt Amplifier for public address systemselector for individual zone as well as whole complex. ( No of zones and other details as shown on drawings.) The operating voltage shall be 24V D.C. & shall include solid state circuits, battery charger, batteries, 60 watt amplifier etc. and fire/ fault/ test positions selector switches, zone isolation facility etc. complete. Supplying, fixing testing & commissioning PVC insulated 2 x1.5 Sq.mm copper conductor wires laid in 20mm dia 16 SWG concealed MS conduit with all necessary conduit accessories etc. Supplying, fixing testing & commissioning EXIT Sign Board . TOTAL Each 151
Each
Each
38
Each
14
Each
14
Each
Mtr
2000
8.
Each
14
CUTTINGS _____________
ADDITIONS _____________
OVER WRITINGS______________
Z O N A L O F F I C E B U I L D I N G F O R B A N K O F I N D I A A T S E C T O R -3 1 - A , C H A N D IG A R H
S.No
Description
Units
Qty
D) a
PUMPS AND ACCESSORIES Work under this section to be carried out by specialist contractor only. The motor HP to be confirmed by the supplier for the duty mentioned for each pump. Rates quoted shall be in inclusive of all structural supports and clamps as per approved design. Electrical Motor Driven Fire Pumping set suitable for automatic operation consisting of the following as per the specifications: i Horizontally mounted, centrifugal type single / multi stage fire pump having cast iron body, bronze impeller, stainless steel complete with necessary pot strainer / Y Type on the suction side and pressure gauge with GM cocks on the delivery side including bypass arrangement (with 50 valve and upto 5M M.S. Heavy Duty pipes) for periodical testing of the working of the testing of the working of the pumping set as per TAC rules. Squirrel cage induction motor totally enclosed fan cooled type suitable for 415 Volts + 10% - 15% , 3 phase, 50 HZ A.C. supply of suitable capacity. The pump coupled with flexible coupling including a earthling as per relevant Indian Standard & specifications.
ii
iii Common bed plate for mounting Pump and Motor fabricated of Motor fabricated of suitable M.S.Channel as per manufacturers recommendations. iv Suitable RC.C Pump-Foundations as per manufacturer's design and 4 nos. Dunlop (cushy foot) heavy duty Ant vibration mounting pads.
CUTTINGS _____________
ADDITIONS _____________
OVER WRITINGS______________
Z O N A L O F F I C E B U I L D I N G F O R B A N K O F I N D I A A T S E C T O R -3 1 - A , C H A N D IG A R H
10
Description
Units Each
Qty 1
Fire Jockey Pump Capacity 180 LPM Head 70 M HP 15.0 Motor RPM 2900 Diesel Engine Driven Fire Pumping set suitable for automatic operation consisting of the following as per specifications: a) Horizontally mounted, centrifugal type single stage/ multi-stage fire pump having cast iron body, bronze impeller, stainless steel shaft complete with necessary pot / Y Type strainer on the suction side and pressure gauge with stop cocks etc, on the delivery side including bypass arrangement (with 50 mm dia G.M. stop valve and upto 5M G.I. stop valve and upto 5M M.S. pipes) for periodical testing of the pumping set b) Water cooled Diesel Engine suitable for developing at least 65 BHP at 1800 RPM) for above pump complete with automatic starting mechanism, batteries, automatic battery charger unit, flexible coupling with the pump, coupling with the pump, fuel tank, silencer, exhaust pipe with insulation appro.25m length & all standard accessories as required including earthing, mandatory spares and tool kit. c) Common bed plate for mounting Pump and Engine fabricated of suitable M.S.Channel as per manufacturer's recommendations. d) Suitable RCC Pump foundations as per manufacturer's design 8 Nos Dunlop Anti-vibration (cushy foot) heavy duty mounting pads.
CUTTINGS _____________
ADDITIONS _____________
OVER WRITINGS______________
Z O N A L O F F I C E B U I L D I N G F O R B A N K O F I N D I A A T S E C T O R -3 1 - A , C H A N D IG A R H
11
Units Each
Qty 1
Providing and fixing dust and vermin proof cubical type motor control centre fabricated from 2mm thick sheet with stove enameled finish and comprising of i One incoming main moulded case circuit breaker of 500 AMP rating. ii One fully taped aluminiuin bus bar of 500 AMP capacity in separate bus. iii One isolation switch fuse units of 250 AMPS with HRC fuses of 200 AMPS rating for fire pumps. iv One isolation switch fuse unit with HRC fuses of 63 AMPS rating one jockey pump. v Two fully auto transformer starter with push buttons and ON/OFF indicating lights for fire pump. vi One rotary heavy duty selector switches for fire pump. vii One 144 x 144 mm panel type volt meter reading 0-500 V with rotary selector switch for reading voltage between phases. vii One 144 x 144 mm panel ampere meter i reading 0-300 AMPS for fire pump. ix One square panel type ampere meter reading 0-50 AMPS for jockey pump. x Appropriate etched plastic plate for each starter /switch gear, starters, meters indicating lamps complete in all respect. xi One single phasing preventor for each phase motor.
Each
CUTTINGS _____________
ADDITIONS _____________
OVER WRITINGS______________
Z O N A L O F F I C E B U I L D I N G F O R B A N K O F I N D I A A T S E C T O R -3 1 - A , C H A N D IG A R H
12
S.No
Description Notes (The rating of all switch gear must match the HP of all sumps quoted).
Units
Qty
Terrace Booster Pump: Providing and fixing multi stage horizontal centrifugal mono block pump with volute bronze impeller connected to TEFC induction motor suitable for 400/410 Volts, 3 Phase, 50 Cycles, AC supply with the following specifications: (Required as per Code) A Capacity : 900 LPM Head : 20 m HP : 7.5 hp approx. or As required. Mover : Electric Motor driven Material of Construction: Shaft & Sleeve : S.S. 410 Impeller : Bronze Bearing : Grease lubricated Seal : Mechanical Seal Quantity : 1 No. Providing and fixing horizontal single stage high speed pumping set with CI body brass impeller, stainless steel shaft and connected by flexible fan cooled induction motor with all pump accessories with starter suitable for 400 volts3 phase,50 Hz Ac supply having following duty :A Domestic water Pumps No. of pumps 2 Nos. Capacity 300 LPM Head 45 Mtr Motor HP 10 The pump set shall be complete with: a) 1 No. M.S. Fabricated Base Plate b) Suitable size RCC pump foundation. c) Making necessary Electrical Connections. Set 1 Each 1
CUTTINGS _____________
ADDITIONS _____________
OVER WRITINGS______________
Z O N A L O F F I C E B U I L D I N G F O R B A N K O F I N D I A A T S E C T O R -3 1 - A , C H A N D IG A R H
13
S.No 6
Description Providing and fixing solid state level controllers for law and high level cut off for under ground/ over head tank installation, complete. Providing and installing submersible pump with cast iron body, bronze impellers, stainless steel shaft and water lubricated hearing . the pump shall have the following characteristics (Both the pumps shall operate simultaneously if required) complete with starter. A Sump pumps suitable for muddy water. a. No. of pumps -1 Nos. b. Capacity -500 LPM c. Head -9 Mtr d. Motor HP -3.0 Sump pumps suitable for muddy water. a. No. of pumps -1 Nos. b. Capacity -100LMP c . Head -9 Mtr d. Motor HP -1.0 Providing and fixing cast iron butterfly valves with epoxy coated disc, carbon steel shaft and lever actuator tested to 10 Kg-/cm 2 (50 mm dia) Providing and fixing brass non return valve of approval quality. 50 min dia Providing, and fixing heavy duty PVC insulated &, PVC sheathed armoured aluminium conductor cables 1000V grade including necessary support clamps and connection plugs complete in all respects. A B C D E Power cable 3 core 120 sqmm. Power cable 3 core 70 sqmm. Power cable 3 core 35 sqmm. Power cable 3 core 16 sqmm. Power cable 3 core 6 sqmm.
Units Each
Qty 2
Set
Set
Each
Each
10
15 15 15 15 15
CUTTINGS _____________
ADDITIONS _____________
OVER WRITINGS______________
Z O N A L O F F I C E B U I L D I N G F O R B A N K O F I N D I A A T S E C T O R -3 1 - A , C H A N D IG A R H
14
S.No 11
Description Providing and fixing 4.00 mm (8 swg) dia GI wire on surface or in recess for loop earthing as required. Providing and fixing 25 mm x 5 mm GI strip on surface or in recess for earth connections etc, as required. Earthing with GI earth plate 600 mm x 600mm x 6mm thick including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc (but without charcoal or coke and salt complete as required. Extra for using salt and charcoal for GI plate or copper plate earth electrode as required. Alarm system for fire pumps comprising of audible hooter and red blinking lamp wired to pressure switch including cost of pressure switch connected on air vessel complete In all respects. Providing and fixing MS structural work (fabricated from standard sections eg. MS rounds, angles,channels, Including cutting to size drilling welding, fixing and welding to insert plates in RCC structural members as directed by the engineer-in-charge including cutting and making good the walls and floors.(for cable trays) TOTAL
Units Meter
Qty 20
12
Meter
13
13
Set
14
Set
15
Each
16
Kg
200
CUTTINGS _____________
ADDITIONS _____________
OVER WRITINGS______________
Z O N A L O F F I C E B U I L D I N G F O R B A N K O F I N D I A A T S E C T O R -3 1 - A , C H A N D IG A R H
15
S.No
Description
Units
Qty
CUTTINGS _____________