Voici le dimensionnement d’acier sur les deux directions et les sections mises en place :

CALCUL DES ACIERS DE FLEXION AU BAEL ET AU FASC.74

FACE EXTERIEURE FACE INTERIEURE

Repère section 1 2 3 4 5 6 8 8
Direction MXX+ MXX+ MYY+ MYY+ MXX- MXX- MYY- MYY-

b0 [m] 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00


h [m] 0.40 0.40 0.40 0.40 0.40 0.40 0.40 0.40
d [m] 0.28 0.28 0.31 0.31 0.28 0.28 0.31 0.31
d' [m] 0.07 0.07 0.09 0.09 0.07 0.07 0.09 0.09
e [cm] 5 5 5 5 5 5

fck [Mpa] 40 40 40 40 40 40 40 40
fctm [Mpa] 3.51 3.51 3.51 3.51 3.51 3.51 3.51 3.51
fy k [Mpa] 500 500 500 500 500 500 500 500
ae 15.00 15.00 15.00 15.00 15.00 15.00 15.00 15.00

f utilisé [mm] 14 14 14 14 14 14 14 14
Règlement Fascicule 74 Fascicule 74 Fascicule 74 Fascicule 74 Fascicule 74 Fascicule 74 Fascicule 74 Fascicule 74
ss [Mpa) 188.5 188.5 188.5 188.5 188.5 188.5 188.5 188.5

M [kN.m] 3.6 13.9 19.5 3.7 3.6 13.9 19.5 3.7


MDT 8.43 8.43 8.43 8.43 8.43 8.43 8.43 8.43
Mtotal [kN.m ] 12.0 22.4 28.0 12.2 12.0 22.4 28.0 12.2
N [kN]

CALCUL DES ACIERS ET VERIFICATION DE LA CONTRAINTE DE BETON EN COMPRESSION

As [cm²] 2.42 4.57 5.19 2.21 2.42 4.57 5.19 2.21


As ' [cm²]
As mini [cm²] 5 5 5 5 5 5 5 5

sb [Mpa] 2.20 3.12 3.17 1.99 2.20 3.12 3.17 1.99


sbc lim [Mpa] 18 18 18 18 18 18 18 18

ACIERS MIS EN PLACE

f principal [mm] 14 14 14 14 14 14 14 14
nb / ml 5 5 5 5 5 5 5 5
f renfort [mm]
nb / ml [m]

As [cm²] 5.00 5.00 5.19 5.00 5.00 5.00 5.19 5.00


Section tendue [cm²] 7.70 7.70 7.70 7.70 7.70 7.70 7.70 7.70
Section comprimée [cm²]
Soi t : HA 14 esp. 20 Soi t : HA 14 esp. 20 Soi t : HA 14 esp. 20

CALCUL DES CONTRAINTES DANS LE BETON

ss [MPa] 61.3 114.0 129.0 56.2 61.3 114.0 129.0 56.2


ssc [MPa] 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
sbc [MPa] 1.4 2.5 2.7 1.2 1.4 2.5 2.7 1.2
s bc lim [MPa] 18.0 18.0 18.0 18.0 18.0 18.0 18.0 18.0

Ach [m²] 0.412 0.412 0.412 0.412 0.412 0.412 0.412 0.412
x [m] 0.202 0.202 0.203 0.203 0.202 0.202 0.203 0.203
Ich [m4] 0.005 0.005 0.005 0.005 0.005 0.005 0.005 0.005

ssr [MPa] 20.17 20.17 27.52 27.52 20.17 20.17 27.52 27.52
sscr [MPa]

s ct [MPa] 0.44 0.82 1.01 0.44 0.44 0.82 1.01 0.44


s ct lim [m m ] 5.50 5.50 5.50 5.50 5.50 5.50 5.50 5.50
OK OK OK OK OK OK OK OK

REACAPITULATIF DES SECTIONS MISES EN PLACE (CM²/ML)

FACE EXTERIEURE DU VOILE FACE INTERIEURE DU VOILE

7.70
7.70

7.70 7.70 7.70 7.70

7.70 7.70

Voici la vérification d’effort tranchant :


𝐸𝐿𝑈
𝑉𝑚𝑎𝑥 157.26 ∗ 103
𝜏𝑢 = = = 0.52 𝑀𝑃𝑎 < 𝜏𝑢𝑙𝑖𝑚 = 0.6 + 0.06 ∗ 𝑓𝑐28 = 3 𝑀𝑃𝑎
𝑏𝑑 1000 ∗ 300
La section est vérifiée, on ne ajoutera pas des armatures d’effort tranchant.
1. Principes

Nous présentons ci-après les principes d’armatures de la zone de raccordement :