Vous êtes sur la page 1sur 1

Rapid Transit & Locomotive Wire and Cable

Polyrad XT-TX Flexible Wire and Cable

600V, Single Conductor, NYCTA Type TX


Product Construction
Conductor: 20 AWG thru 4/0 AWG soft annealed tinned copper per ASTM B-33, B-8 and B-172 Insulation: Polyrad XT flame-retardant, low-smoke irradiated Cross-Linked Polyolefin (XLPO) Print: GENERAL CABLE BRAND REX BRAND (WC) POLYRAD XT - TX XXAWG 600V NYCTA TX 20-88XXXX DAY/MONTH/YEAR XXXX = NYCTA TX Stock Code - Last X is used to identify Insulation Color as listed below: 0 = Black, 1 = White, 2 = Red, 3 = Blue, 4 = Green, 5 = Orange, 6 = Yellow, 7 = Gray, 8 = Brown, 9 = Purple options: Available in multi-conductor constructions Available in colors other than dark gray

600 Volt Chart


CATALOG NUMBER NYCTA TYPE TX STOCK CODE NUMBER CONDUCTOR (AWG/kcmil) SIZE AND STRANDING NOMINAL CONDUCTOR DIAMETER INCHES MM MINIMUM AVERAGE NOMINAL INSULATION CABLE THICKNESS DIAMETER MILS MM INCHES MM COPPER WEIGHT lbs/1000' kg/km NET CABLE WEGHT lbs/1000' kg/km AMPACITY (Free Air 40C Ambient) 110C

applications
Ideally suited for use where environmental factors require cable characteristics to perform with a high degree of flame retardancy and excellent moisture-stable electrical values. Where reliability is the major concern and where maximum performance will be demanded Engineered and manufactured for both original equipment and retrofit use in power and control circuits, and in motor leads Extensively found on all types of heavy- and light-rail cars, rapid transit cars, diesel-electric locomotives, freight cars, wayside equipment and off-road vehicles

389980 389990 389740 390000 390010 390020 390030 390040 390050 390060 390070 390080 390090 390100 390110 390120 390130

20-88-150X 20-88-170X 20-88-190X 20-88-210X 20-88-230X 20-88-250X 20-88-270X 20-88-290X 20-88-310X 20-88-330X 20-88-380X 20-88-460X

20 18 16 14 12 10 8 6 5 4 3 2 1 1/0 2/0 3/0 4/0

19/32 19/30 19/29 19/27 19/25 27/24 37/24 61/24 91/24 105/24 125/24 150/24 225/24 275/24 325/24 450/24 550/24

0.038 0.048 0.054 0.067 0.086 0.117 0.135 0.174 0.242 0.262 0.285 0.307 0.380 0.410 0.470 0.549 0.593

0.97 1.22 1.37 1.70 2.18 2.97 3.43 4.42 6.15 6.65 7.24 7.80 9.65 10.41 11.94 13.94 15.06

30 30 30 30 30 30 45 45 45 45 45 45 55 55 55 55 55

0.76 0.76 0.76 0.76 0.76 0.76 1.14 1.14 1.14 1.14 1.14 1.14 1.40 1.40 1.40 1.40 1.40

0.100 0.110 0.116 0.129 0.148 0.179 0.227 0.266 0.334 0.354 0.377 0.399 0.494 0.524 0.584 0.663 0.707

2.54 2.79 2.95 3.28 3.76 4.55 5.77 6.75 8.48 8.99 9.58 10.14 12.55 13.31 14.83 16.84 17.96

4 6 8 12 19 34 47 76 116 137 167 190 287 351 407 594 696

6 9 13 18 28 50 70 114 173 204 249 283 427 522 606 884 1036

9 12 13 18 27 43 63 97 141 164 193 220 349 417 474 655 774

13 18 19 27 40 64 94 144 210 244 287 327 519 621 705 975 1152

24 30 35 41 52 73 85 120 160 168 199 214 268 304 338 414 472

Features
Cables meet NYCTA TX specification Temperature rating at 110C Excellent flexibility & free stripping Higher ampacities and simplified installations possible due to small outside diameters, flexible stranding and insulation Outstanding thermal stability at elevated temperatures Maximum flame-retardance and low toxicity Excellent low-temperature performance; suitable for installation in sub-zero conditions Extra tough, mechanically rugged irradiated thermoset insulation Resistant to most oils and chemicals Meets cold bend test at 55C Meets cold impact test at 40C

Dimensions and weights are nominal; subject to industry tolerances. Note: At the option of the purchaser, the manufacturers standard type of stranding will be acceptable providing that the conductor diameter does not exceed the values shown. The total number of wires shall be as specified, plus or minus one percent, except 150/24 which may vary by minus two percent, providing that the conductor diameter does not exceed the values shown. Please consult Customer Service for price and delivery.

Compliances
Industry: AAR S-501/AAR RP-585 ICEA S-95-658 Flame test: IEEE 1202 (70,000 BTU/hr) IEEE 383 (70,000 BTU/hr) VW-1 other: BSS 7239 SMP 800-C ASTM E662 Meets requirements of 49 CFR Part 238 for flame and smoke requirements

Packaging
Standard reel put-up

Vous aimerez peut-être aussi